Sie sind auf Seite 1von 2

ANALISIS DE DATOS

MARCA TERCO YOKOHAWA DIGITAL PINZA


ERROR 2.5 2.5 0.5 0.5
VOLTAJE CORRIENTE CORRIENTE CORRIENTE CORRIENTE
100v 1.15A 1.18A 1.144A 1.194A
120v 1.29A 1.29A 1.26A 1.313A
150v 1.42A 1.48A 1.421A 1.486A
200v 1.69A 1.72A 1.66A 1.725A
DISCREPANCIA ENTRE INSTRUMENTOS

VOLTAJE TERCO - PINZA


100v |1.15A-1.194A|=0.044A
120v |1.29A-1.313A|=0.023A
150v |1.42A-1.486A|=0.046A
200v |1.69A-1.725A|=0.035A

VOLTAJE TERCO - YOKOHAWA


100v |1.15A-1.18A|=0.03A
120v |1.29A-1.29A|=0A
150v |1.42A-1.48A|=0.06A
200v |1.69A-1.72A|=0.03A

VOLTAJE TERCO - DIGITAL


100v |1.15A-1.144A|=0.014A
120v |1.29A-1.26A|=0.03A
150v |1.42A-1.421A|=0.001A
200v |1.69A-1.66A|=0.03A

VOLTAJE YOKOHAWA - DIGITAL


100v |1.18A-1.144A|=0.036A
120v |1.29A-1.26A|=0.03A
150v |1.48A-1.421A|=0.059A
200v |1.72A-1.66A|=0.06A

VOLTAJE
VOLTAJE YOKOHAWA-
DIGITAL - PINZA PINZA
100v
100v |1.18A-1.192A|=0.014A
|1.144A-1.192A|=0.05A
120v
120v |1.29A-1.313A|=0.023A
|1.26A-1.313A|=0.053A
150v
150v |1.48A-1.486A|=0.006A
|1.421A-1.486A|=0.065A
200v
200v |1.72A-1.725A|=0.005A
|1.66A-1.725A|=0.063A
COMPARACION ENTRE EL VALOR TEORICO

VOLTAJE POTENCIA VALOR TEORICO DE


CORRIENTE
100v 167W 1.167A
120v 155W 1.2883A
150v 218W 1.4518A
200v 340W 1.6987A

VOLTAJE VT CORRIENTE - E%
TERCO
100v |1.167A -1.15A|=0.017A 1.46%
120v |1.2883A -1.29A|=0.0017A 0.132%
150v |1.4518A -1.42A|=0.0318A 2.19%
200v |1.6987A -1.69A|=0.0087A 0.512%

VOLTAJE VT CORRIENTE - E%
YOKOGAWA
100v
VOLTAJE |1.167A -1.18A|=0.013A
VT CORRIENTE - 1.114
E%
120v |1.2883A -1.29A|=0.0017A
DIGITAL 0.1319
150v
100v |1.4518A
|1.167A -1.48A|=0.0282A
-1.144A|=0.023A 1.94
1.97%
200v
120v |1.6987A-1.26A|=0.0283A
|1.2883A -1.72A|=0.0213A 1.254
2.19%
150v |1.4518A -1.421A|=0.0308A 2.697%
200v |1.6987A -1.66A|=0.0387A 2.27%

VOLTAJE VT CORRIENTE - E%
PINZA
100v |1.167A -1.194A|=0.027A 2.31%
120v |1.2883A -1.313A|=0.0247A 1.917%
150v |1.4518A -1.486A|=0.0342A 2.36%
200v |1.6987A -1.725A|=0.0263A 1.55%