Application
The VisionBox allours the setting of the parameter values of Note: Passwords are required to install the software and
DUNGS control devices via PC, Laptop or Tablet PC for parameterization of the systems.
(from WIN 10, with USB connection). Please contact your DUNGS sales representative for the
passwords your require.
Suitable for:
MPA 4xxx The VisionBox program is based on Microsoft Excel, the
MPA 51xx operation of selecting cells and to view possible additio-
VPM nal functions are identical.
2. Warnings
2.1 General warnings
Never carry out work as long as gas The device may only be operated in
pressure or voltage is applied. Avoid compliance with the operating condi-
open fire. Please observe public regu- tions stated on the type plate.
lations.
Prior to assembly, the device must be The device must be protected from
inspected for transport damage. vibrations and mechanical impacts.
The device must not be exposed to The device must not be used in areas
open fire. Protection against lightning with increased seismic risk
strikes must be guaranteed.
M • Edition 08.16 • Nr. 270 173
The device is used in accordance with its designated use • Use in perfect condition only.
if the following instructions are observed: • Malfunctions and faults must be eliminated immedi-
• Applicable only with suitable DUNGS systems and ately.
software • Use only in observance of the instructions given in this
• Use only in compliance with the operating conditions instruction manual and of national regulations.
stated on the type plate.
• If used in accordance with their designated use, the • Operator errors or misuse present risks to life and
devices are safe to operate. limb of the operators and also to the device and other
• Non-observance of the regulations may result in per- material property.
sonal injury or material damage, financial damage or
environmental damage.
2 … 26
4. Table of contents
1. Target group 1
2. Warnings 1
2.1 General warnings 1
2.2 Designated use2
2.3 Risks in case of misuse2
3. Approval/declaration of conformity 2
4. Table of contents3
5. Inhalt VisionBox mini 4
6. Software Download and Installation 6-9
7. Connection VisionBox 10
8. Operation VisionBox Software 11-13
8.1 Change of access level 14-15
8.2 Copy of a existing parameter set 15
8.3 Change of parameter 16-17
9. Error overview 18
10. VisionBox Update Software 19
11. VisionBox Update error messages 19-20
12. Documentation device configuration 21-22
13. Send device configuration via email 23
14. Reset to factory setting 24
M • Edition 08.16 • Nr. 270 173
3 … 26
5. Content VisionBox mini
VisionBox
M • Edition 08.16 • Nr. 270 173
4 … 26
6. Software Download and Installation
www.dungs.com/softwaretools
> VisionBox
Installation:
Press „Ausführen“
Confirm „Next“
5 … 26
6. Software Download and Installation
Enter Password
7 … 26
6. Software Download and Installation
8 … 26
6. Software Download and Installation
9 … 26
7. Connection VisionBox
1. De-energize MPA / VPM. ATTENTION: Line voltage, don´t touch any live parts.
2. Connect the 4-pin connector of the VisionBox to the ter- Mind the safety rules when working with energized elec-
minal „TWI“ - note encoding. trical components.
3. Connect the VisionBox to the computer / laptop and
start the PC / Laptop.
LED Power – on
4. Energize MPA / VPM.
LED MPA – on
LED PC – flashing
LED Power – on
LED MPA – on
LED PC – flashing
10 … 26
8. Operation VisionBox Software
11 … 26
8. Operation VisionBox Software
Standard View
The standard view shows:
Status: Operating condition of the connected controlbox
Error overview: Contend of the error memory of the connected controlbox
Parameter overview: Current parameter setting of the connected controlbox
M • Edition 08.16 • Nr. 270 173
12 … 26
8. Operation VisionBox Software
View: Online-Datenlog
The view „Online-Datalog“ provides a graphical overview
of the burner functions.
M • Edition 08.16 • Nr. 270 173
13 … 26
8.1 Change of access level
To adapt or change parameters is done for all DUNGS devices according to the same procedure.
However, the devices differ in the activation of new values.
Please refer to the corresponding operating and installation instructions.
Password levels
Level 5: Operator / no password / no change authorization
Level 4: Service / password / limited change authorization
Level 3: OEM / Password / full editing rights
Level 2: OEM expert / password / full editing rights incl. expansion variable upper and lower limits
Level 1: DUNGS / password / developer level
Enter password
Select Access Level
Confirm with OK
M • Edition 08.16 • Nr. 270 173
14 … 26
Confirm change of the access level by
pressing the RESET button on the MPA /
VPM
15 … 26
8.3 Change of parameter
Example Change prepurge time
M • Edition 08.16 • Nr. 270 173
16 … 26
The value (time in seconds) for the pre-
purge time may be entered direct in the
value window, by using the +/- buttons or
by moving the value pointer.
Select parameter and activate the parameter by double- Alternatively, via a selection menu (click right mouse
click in the value field. button) the parameters are enabled for change.
The values are saved immediately after
the confirmation in the control, to enable
the parameter change refer to the relevant
operating and installation instructions.
M • Edition 08.16 • Nr. 270 173
17 … 26
9. Error overview
The error overview shows the last ten in the control stored
errors.
The error ID refers to the error description in the corre-
sponding operating and installation instructions.
18 … 26
10. VisionBox Update Software
If the VisionBox is connected to the PC / laptop via USB If a later version of the firmware available a update window
and the software is started, the program automatically automatically opens.
performs a check of the software status of the VisionBox.
M • Edition 08.16 • Nr. 270 173
19 … 26
11. VisionBox update, error messages
M • Edition 08.16 • Nr. 270 173
20 … 26
12. Documentation device configuration
21 … 26
The information which will shown in the
file can be selected by putting a check-
mark into the selection fields
Light grey fields cannot be shown.
22 … 26
13. Send configuration via email
23 … 26
14. Reset to factory setting
To write the factory setting to the device,
choose “Write all parameters” by pressing
the right mouse button.
M • Edition 08.16 • Nr. 270 173
24 … 26
25 … 26
M • Edition 08.16 • Nr. 270 173
The Pressure Equipment Directive (PED) and the It is necessary to replace safety-relevant com-
Energy Performance of Buildings Directive (EPBD) ponents after they have reached the end of
require a periodic inspection of heating applianc- their useful life. This recommendation applies
es in order to ensure a high degree of efficiency only to heating appliances and not to indus-
over a long term and, consequently, the least envi- trial heating processes. DUNGS recommends
ronmental pollution. replacing such components according to the
following table: