Sie sind auf Seite 1von 2

TECHNICAL DATA SHEET

uni tronic™ 600


Electronic Blasting System

Technical Properties
Detonator wire lengths 3 – 55 m (10 – 180 ft)
Number of wire types One
Blast boxes 310 / 310R
Scanners 120 / 125 / 200
Harness wire types Duplex
Max delay time 10 seconds
Max number of Single box 800
detonators per
blast 2 in Synchro 1600

• uni tronic™600 Tester for safe on-bench communication


with Scanner 120 or 125 for testing of uni tronic™600
detonators
• Duplex harness wire

Application
The uni tronic™600 Detonators have a bar code printed on the
flag tag which contains the detonator’s unique ID. The user
scans this label to capture the ID and links it with a firing time
by using the convenient auto-increment timing function in the
Scanner. The uni tronic™600 system is surprisingly easy to
learn and to use, making it particularly applicable in small and
medium opencast coal, in the quarry & underground aggregate
industries, and in construction.

Key Benefits
Description • The uni tronic™600 system is ideal for quarry operators
The uni tronic™600 Electronic Blasting System offers one of searching for effective means to reduce vibration during
Orica’s exciting Next Generation technologies – uni blasting and to minimize the effect of operational or
tronic™600. The product enables an increasing range of users regulatory constraints on output.
to experience the benefits of electronic blasting at an • In many cases, blast pattern expansion using the uni
economical price point. tronic™600 system will mitigate or offset any cost
• The system consists of: premium.
• uni-tronic™600 electronic detonators • Open pit coal operators will appreciate not only the
• Blast Box 310 (with Bluetooth) / 310R (with wireless vibration reduction, but also the potential benefits of
Remote firing) cleaner, more stable highwalls, less backbreak, and
• Scanner 110 / 120 / 125 improved cast performance.
• Scanner 200, with on-bench, full-function testing of uni • Fragmentation improvement has been a hallmark of
tronic™600 detonators electronic blasting, with resulting benefits in haul truck fill

V1.7 19/04/16
1 of 2
TECHNICAL DATA SHEET

uni tronic™ 600


Electronic Blasting System

• rates, crusher throughput, lower maintenance and overall See Safety Data Sheet for more information.
cost reductions.
• The uni tronic™600 Electronic Blasting System offers
increased safety and security for all operators through
knowing the condition of every hole before a blast, and in
Disclaimer
the use of specific, dedicated equipment to control, © 2015 Orica Group. All rights reserved. All information
program and fire the detonators. contained in this document is provided for informational
• The uni tronic™600 detonator allows safe, on-bench purposes only and is subject to change without notice. Since the
testing of detonators to ensure that every one of them is Orica Group cannot anticipate or control the conditions under
ready to function at blasting time. which this information and its products may be used, each user
should review the information in the specific context of the
intended application. To the maximum extent permitted by law,
Recommendations for Use the Orica Group specifically disclaims all warranties express or
uni tronic™600 detonators can only be tested, programmed implied in law, INCLUDING ACCURACY, NON
and fired using dedicated uni tronic™600 equipment. Do not INFRINGEMENT, AND IMPLIED WARRANTIES OF
use any other programming or blasting equipment. Damage to MERCHANTABILITY OR FITNESS FOR A PARTICULAR
the legwire insulation is the most common cause of problems PURPOSE. The Orica Group specifically disclaims, and will not
with electronic blasting systems; exercise care and protect the be responsible for, any liability or damages resulting from the
wires when loading and stemming holes. use or reliance upon the information in this document.

Available Lengths / Packaging The word Orica and the Ring device are trademarks of the Orica
uni tronic™ detonators are available in wire lengths from 6m Group.
(20ft) to 55m (180ft) and in both 1.1B and 1.4S packaging.
The harness wire is available in 400m draw-from-center rolls For more information please visit our website: www.orica.com
and in 500m spools.
Orica USA Inc. Orica Canada Inc.
Storage and Handling 33101 East Quincy Ave 301 Hotel de Ville
Detailed guidance for proper transport, storage and operation Watkins, CO 80137 Brownsburg,
appears in the Technical Data Sheets for uni tronic™ Tel: +1 303 268 5000 QC J8G 3B5
detonators and equipment. Fax: +1 303 268 5250 Tel: +1 303 268 5000
Fax: +1 303 268 5250
Disposal
Disposal of explosive materials can be hazardous. Methods of
safe disposal of explosives may vary depending on the user’s Emergency Telephone Numbers
situation. Please contact an Orica Technical Services For chemical emergencies (24 hour) involving transportation,
Representative for information on safe practices. spill, leak, release, fire or accidents:

Safety Canada: Orica Canada emergency response 1-877-561-3636


uni tronic™ 500 detonators must not be used with uni USA: Chemtrec 1-800- 424-9300
tronic™600 equipment. uni tronic™600 electronic initiating
systems provide a high level of safety against initiation by For lost, stolen or misplaced explosives:
static electricity, stray electrical currents and radio frequency USA: BATFE 1-800-800-3855. Form ATF F5400.0 must be
transmissions. However, uni tronic™600 detonators contain completed and local authorities (state / municipal police, etc.)
pyrotechnics and molecular explosives, which can initiate must be advised.
under intense impact, friction or heat. As with all high
explosives, these detonators must be handled and stored with
care. uni tronic™600 detonators may only be used at
temperatures up to 158 ºF / 70ºC. Seek advice from Orica for
priming systems suitable for higher temperatures.

V1.7 19/04/16
2 of 2

Das könnte Ihnen auch gefallen