Sie sind auf Seite 1von 2

Rev Description By Chkd Appd Date

O
1
First Issue Sunil Mike Mike 17-Jan-19
Finepac
2 Structures
3
4 Process Calculation Sheet
V-11D

ME-Calc+ Mist Eliminator Size Calculator

Project Name Flue Gas 


Job Ref No
Customer Nitisn Shah 
Vessel Name
Tag No N/a
Vessel Orientation Vertical (Select)
Gas Flow thru Demister Vertical (Select)
 
Input Data
Design Case
Operating Pressure Barg -0.40 -0.40 -0.40
o
Operating Temperature C 40.0 40.0 40.0
Basis:
Gas Flowrate kg/h 20,664 20,664 20,664 Nm3 at 0oC, 1.013 bara
Gas MW # 28.00 28.00 28.00 Sm3 at 15oC, 1.013 bara
Gas Viscosity cP 0.0070 0.0070 0.0070
Gas Density Std kg/Nm3 1.2496 1.2496 1.2496
Gas Density Op kg/m3 0.0574 0.06 0.06
Gas Flow (Actual at T,P) Am3/h 360,000.0 360,000.0 360,000.0
Gas Flow Nm3/h 16,537 16,537 16,537
Sm3/h 17,445 17,445 17,445
MMSCFD 14.8 14.8 14.8
Light Liquid Name
Light Liquid Density kg/m3 780.0 780.0 780.0
Viscosity cP 4.00 4.00 4.00
Flowrate kg/h 0.0 0.0 0.0
Flowrate Am3/h 0.0 0.0 0.0
Surface Tension mN/m 17.78 17.78 17.78

Heavy Liquid Name


Heavy Liquid Density kg/m3 1,000.0 1,000.0 1,000.0
Viscosity cP 1.00 1.00 1.00
Flowrate kg/h 206.0 206.0 208.0
Flowrate Am3/h 0.2 0.2 0.2
Surface Tension mN/m 65.00 65.00 65.00

Total Feed Flowrate In kg/h 20,870 20,870 20,872


Am3/h 360,000.2 360,000.2 360,000.2
Feed Mixture Density kg/m3 0.06 0.06 0.06

Fraction of Liquid in Feed ppmw 9,871 9,871 9,966


ppmv 1 1 1
% vol 0.000 0.000 0.000
mg/Nm3 12,457 12,457 12,578

Solids Flowrate mg/Nm3 400.0 400.0 400.0


kg/h 6.6 6.6 6.6
ppmw 316.9 316.9 316.9

Document Title Document No.


THIS DOCUMENT IS ISSUED AS PRELIMINARY DESIGN INFORMATION ONLY AND NO LIABILITY IS
ACCEPTED OR IMPLIED FOR ACCURACY. ALL DATA SHOULD BE CHECKED AND VERIFIED BY
QUALIFIED PERSONNEL.
Mist Eliminator Sizing
Sheet 1 of2
Rev Description By Chkd Appd Date
O
1
First Issue Sunil Mike Mike 17-Jan-19
Finepac
2 Structures
3
4 Process Calculation Sheet
V-11D

ME-Calc+ Mist Eliminator Size Calculator

Project Name Flue Gas


Job Ref No 0
Customer Nitisn Shah
Vessel Name 0
Tag No N/a
Vessel Orientation Vertical
Vessel Dimensions 5,000 mm ID 14,000 mm T/T

Vane Mist Eliminator

Gas Flow Orientation Vertical

Vane Pack Properties Vertical N/A


Pack Thickness mm 200
Vane Spacing mm 20
No of Bends # 4 Kmax m/s
Vane Type Hooked 0.200

Design Case 0 0 0
De-rating for Press % Kmax 100.0% 100.0% 100.0%
De-rating for Viscosity % Kmax 100.0% 100.0% 100.0%
De-rating for Surface Ten % Kmax 100.0% 100.0% 100.0%

Recommended K factor Krec 0.200 0.200 0.200

Design K-Factor, Kdes m/s 0.200 0.200 0.200


Flowing Velocity m/s 26.40 26.40 26.40
Momentum Pa 40.0 40.0 40.0 Shape:
Area Required m2 3.79 3.79 3.79 Rectangular

Diameter if Circular mm 2,196 2,196 2,196

Width if Rectangular mm 1,950 1,950 1,950


Height if Rectangular mm 1,943 1,943 1,943

Pressure Drop mbar 4.80 4.80 4.80

Efficiency at 10 Microns % 100.00% 100.00% 100.00%


Efficiency at 20 Microns % 100.00% 100.00% 100.00%
Efficiency at X Microns % 10 100.00% 100.00% 100.00%

Notes:
1)
2)
3)
Document Title Document No.
THIS DOCUMENT IS ISSUED AS PRELIMINARY DESIGN INFORMATION ONLY AND NO
LIABILITY IS ACCEPTED OR IMPLIED FOR ACCURACY. ALL DATA SHOULD BE CHECKED AND
VERIFIED BY QUALIFIED PERSONNEL.
Mist Eliminator Sizing 0
Sheet 2 of 2

Das könnte Ihnen auch gefallen