Sie sind auf Seite 1von 4

Senstar Sensor Integration ®

Flexible Sensor Management and Integration Options

FEATURES AND BENEFITS Integrating a perimeter intrusion detection Key software components
system with site security processes is critical Network Manager initiates and controls all
• Common SMS/PSIM interface for all Senstar to achieve situational awareness and fast communication over the sensor network and
networked sensors, including OmniTrax®, response times. Senstar offers a suite of provides the interface for sensor status and
FlexZone®, XField®, IntelliFIBER™,
software and hardware components that system management.
UltraWave™ and FiberPatrol®
provide a range of integration options:
• Remote access for sensor configuration, The Network Manager software includes the
calibration and troubleshooting • Network Manager following components:
• Centralized system monitoring, including • Sensor network and communication cards • Front Panel – Displays the overall status of
sensor operation, performance, and event
• Gateway media converters the sensors and network. It is also used to
logging
• Configuration and calibration software configure the sensor network and SMS
• Combinational logic operations on multiple
zone/sensor alarms to create virtual zones • Alarm display software interface.
(Alarm Logic Engine) • Software development kit (SDK) with full • Network Manager Service (NMS) – The
• Optional redundant configuration for critical sensor API Network Manager software runs as a
applications Windows service to maximize reliability,
• Software Development Kit (SDK) with API Network Manager security, and remote accessibility.
documentation, test software and simulator • Application Programming Interface (API) –
software The Network Manager software
Provides an interface through which SMS
• Mulitple integration options with Senstar communicates directly with the Senstar
software receives alarm and status
and third-party Security Management sensors and provides a common IP interface
information from the networked sensors.
Systems (SMS) for use by Security Management Systems
The SMS can also use the API to control
• Microsoft Windows® compatible (SMS) or Physical Security Information
networked relay outputs and initiate
• Integrated sensor network reduces system Management (PSIM) systems. It also provides
sensor self-tests.
installation and maintenance costs an access point through which sensor
configuration tools can remotely access • System management tools – A set of
• Monitoring and control of auxiliary utilities for monitoring sensor status and
perimeter security equipment individual sensors.
performing troubleshooting (Plot tool,
• Configurable per-alarm ASCII output Running on the Windows operating system, Event Log tool and Status tool).
messages (serial/TCP/IP) Network Manager can reside on the same
PC as the SMS or on a dedicated PC.
Network Manager connects to the networked
sensors via gateway hardware (EIA-422,
fiber, or Ethernet) installed in the control
room.

DATASHEET
Senstar Sensor Integration | Flexible Sensor Management and Integration Options

Alarm Logic Engine (ALE) ASCII text input/output Network topologies


The ALE performs custom combinational The Network Manager’s ASCII text The Silver Network protocol supports both
logic operations on sensor inputs and input/output capability allows integration loop and star network topologies.
outputs, enabling operators to create with any security management system that
The Silver Network supports loop
custom behaviors and virtual sensors. processes test strings over serial or IP
topologies with separate Transmit (Tx) and
connections.
Scalability Receive (Rx) point-to-point links. It is
Network Manager can scale to include Sensor network and designed to be polled from both ends of
multiple sensor networks, including the communications loop, thus providing
communication cards redundant data paths to the field
remote sites and sensor networks of
different types. Up to 10 instances of any Senstar sensors communicate alarm, equipment. The links can be EIA-422,
combination of Network Manager (Silver™, status and configuration information to single-mode or multi-mode fiber, or in the
Crossfire™, CCC, FiberPatrol) can be run and from a centralized control location case of OmniTrax and FlexZone, over the
on one PC. using their integrated networking sensor cables themselves.
capability.
Network Manager runs as a Windows Depending on the sensor, star topologies
service, rather than as a standard For Senstar’s latest generation sensors over Ethernet links are also supported.
application. Running as a service (OmniTrax, XField, FlexZone and This enables operators to reuse their
increases operational integrity through the UltraWave), the primary network type is existing network infrastucture, such as that
following features: Senstar’s Silver Network™. The Silver already in place for IP cameras and other
Network includes error detection with security devices.
• Services can be configured to start up automatic retries to provide a reliable and
automatically at power-up without the high integrity communications path. Communications cards
need for user log-on Sensor network communication is enabled
• A service can be configured to The Silver Network allows a wealth of through the addition of communications
automatically restart if it crashes information to be communicated, cards. Different communication cards are
including: required depending on the processor and/
• Services can be monitored and
managed from a remote machine • Intrusion alarm status or network interface.
• Operational status including alarm
Network Manager and the SMS can be location, device tamper status and Type Products Interfaces
co-hosted on the same computer or run diagnostic alarms Gen 1 OmniTrax EIA-422
on separate computers communicating • Configuration data, such as thresholds, XField Single-mode fiber
over an IP network. gain settings and zone lengths 16I/O Multi-mode fiber
• Alarm and supervision status of auxiliary Gen 2 FlexZone EIA-422
High availability
inputs FlexPS™ Single-mode fiber
To support the requirement for high
• Control messages for auxiliary relay UltraWave Multi-mode fiber
system availability, Network Manager can UltraLink I/O
outputs
run in a redundant configuration whereby
• Sensor response data for calibration Ethernet FlexZone 10/100Base-TX
two instances run on two separate
and troubleshooting FlexPS with PoE
computers. One Network Manager is
• Firmware updates UltraWave
active while the other is in standby. A UltraLink I/O
heart-beat protocol operates between the • Internal sensor event logs
two so that the standby takes over in the • Sensor diagnostic information such as
event the active one fails. operating temperature, input voltage,
battery voltage and power consumption
Direct output control • Commands to initiate sensor self-test
The Network Manager’s direct output (device-dependent)
control enables any input alarm state to be
configured to control the state of any
output point. “Alarm state” includes any
Network Manager
sensor alarm along with supervision, software running
tamper, diagnostic, and auxiliary input on PC
alarms. “Output point” includes any
physical output (relay, open-collector NM SMS/PSIM
output) and virtual outputs – self-test,
audio control. Network interface
device
A typical use is to have sensor alarms
and/or fault indications control third-party
security equipment via an UltraLink™ I/O Perimeter sensors and
security devices
module’s relay outputs.
Configuration,
calibration and
monitoring software
Site integration architecture
Senstar Sensor Integration | Flexible Sensor Management and Integration Options

Configuration, calibration and Software Development Kit (SDK) Gateway media converter
monitoring software with full sensor API If the sensor network runs over fiber or
Senstar includes a set of software tools EIA-422, a gateway media converter is
Senstar provides an SDK to enable
that enable system maintainers to required to interface the sensors with the
third-party SMS providers to communcate
configure, calibrate, and monitor PC running the Network Manager
with the Network Manager and integrate
networked sensors from a centralized software.
Senstar sensors into their systems.
location. Each tool communicates wth the
The SDK includes: Silver Network Interface Unit (SNIU)
Network Manager over TCP/­­­­IP and can
The SNIU is a rack-mount unit designed
run on separate PCs – a real time-saver • API documentation for loop networks running fiber or EIA-422:
when access to the Network Manager PC • Sample code for interfacing with API
is restricted or inconvenient. (C++, MFC) • Two pairs of sensor network
• A simulator for mimicking a Network connections (one for each end of the
• Universal Configuration Module (UCM) sensor network loop):
Configures and calibrates Senstar Manager connected to an array of
Senstar sensors (enabling developers to • Two EIA-422 connectors
sensors and performs firmware updates
test their software without having (with integrated lightning protection)
• Plot Tool – Records the response of a access to sensor hardware) • Two fiber optic connections
specific sensor and displays up to 8 (multi-mode or single-mode)
channels of recorded or live data API Functionality
The API provided by the Network Manager • PC interfaces (same type must be used
• Status Tool – Displays the status of all for each end of the loop):
provides the alarm display head-end or
sensors on the network • Two USB ports (Type B)
SMS access to all sensor data, including:
• Event Log Tool – Provides remote • Two Ethernet ports (RJ-45)
access to the Network Manager log • Intrusion alarm status
• Two EIA-232 serial ports (DSUB)
files and daily event information • Tamper status
• USB port for device configuration
• Communications status
• Redundancy: Includes a pass-through
• Diagnostic alarm status with fail-over mode
• Dry contact input status • Dimensions: 19-inch rack, 1U height,
• Control of relay outputs 23 cm (9 in) deep
• Sensor self-test initiation • Power: 3W, 12 to 48 VDC
The head-end/SMS communicates with • Indoor-rated
the Network Manager over TCP/IP. During
normal operation, unsolicited status
changes are sent to the SMS. The API also
includes query commands so that the SMS
can request the complete operational
status of the networked sensors.
Universal Configuration Module (UCM)

Silver Network Interface Unit (SNIU)

Mini-SNIU
The Mini-SNIU is a DIN-rail mountable USB
to fiber/EIA-422 converter:
• Interfaces:
• EIA-422
• Fiber optic connections (multi-mode
or single-mode)
• USB port (Type B)
Network Manager Front Panel • Dimensions (H/W/D): 11.5 x 3.2 x 12 cm
(4.5 x 1.25 x 4.75 in)
• Power: USB powered
• Indoor-rated

Mini-SNIU DIN-rail module


Plot tool
Senstar Sensor Integration | Flexible Sensor Management and Integration Options

Moxa Ethernet-to-serial converter Part Numbers


The Moxa converter is a panel or DIN-rail
mountable converter for loop networks
running EIA-422:
SOFTWARE COMMUNICATION CARDS
• Interfaces: Part Number Part Description
• One Ethernet connection (RJ-45) 00FG0220 Network Manager sofware 00BA0301 G1 Silver Network comm
• Two EIA-422/485 interfaces (screw- (service version) for card – multi-mode fiber
terminal connectors) Windows 7/8/10. Includes optic connections
• Dimensions (H/W/D): 11.6 x 10 x 2.6 cm Silver, Crossfire, CCC,
00BA0302 G1 Silver Network comm
(4.6 x 4 x 1.02 in) Sennet, and FiberPatrol
card – EIA-422 connections
versions, management
• Power: 3.2W, 12 to 48 VDC
tools, and AIM software 00BA0303 G1 Silver Network comm
• Temperature: (requires hardware key) card – single-mode fiber
• Standard version: 0 to 60°C (32 to optic connections
00SW0100 Universal Configuration
140°F) 00BA0304 G1 Silver Network comm
Module (UCM) software on
• Extended, outdoor version: CD card – one multi-mode fiber
–40 to 75°C (–40 to 167 °F) optic and one EIA-422
00SW0230 USB security key for Alarm
• Humidity: 5 to 95% (non-condensing) Integration Module (AIM)
connection
software 00BA0305 Gen 1 Silver Network comm
card – one single-mode
00SW0260 Genetec software gateway
fiber optic and one EIA-422
connection`
NETWORK INTERFACE DEVICES 00BA1901 G2 Silver Network comm
card – multi-mode fiber
Part Number optic connections
00EM0200 SNIU (EIA-422 and 00BA2000 G2 Silver Network comm
multi-mode fiber-optic card – EIA-422 connections
Moxa Ethernet-to-serial converter Silver Network
00BA2101 G2 Silver Network comm
connections)
card – single-mode fiber
00EM0201 SNIU (EIA-422 and optic connections
Alarm display software single-mode fiber optic
00BA2200 Ethernet card for G2
Senstar offers several Windows-based Silver Network
sensors, 10/100Base-TX,
alarm display options, each one optimized connections)
PoE
for different customer requirements: 00EM1301 Mini-SNIU (USB to EIA-422
and multi-mode fiber-optic
• Alarm Integration Module (AIM) – A
interfaces). DIN-rail mount.
single-map alarm display, ideal for use
at sites with simple security 00EM1302 Mini-SNIU. USB to EIA-422
environments or as a fall-back display and single-mode fiber-
within a more complex environment. optic interfaces. DIN-rail
AIM is included as part of the Network mount.
Manager software suite (USB key GB0360-ST Ethernet to dual EIA-
required). See the Alarm Integration 422/485 converter
Module datasheet for more information. (standard temperature)
• StarNeT 1000 – A highly customizable GB0360-ET Ethernet to dual EIA-
software package integrating security 422/485 converter
management, device control, and (extended temperature)
sensor configuration. See the StarNeT
1000 datasheet for more information.
• StarNet 2 – A full-featured and easily
configured SMS optimzed for the
management and operation of intrusion
detection systems. See the StarNet 2
datasheet for more information.
Customers may also integrate their own
SMS or alarm display head-end.

info@senstar.com  •  senstar.com
Copyright © 2017. All rights reserved. Features and specifications are subject to change without notice. The Senstar name and
logo, FiberPatrol, FlexZone, OmniTrax and XField are registered trademarks of Senstar Corporation. IntelliFIBER, Crossfire, FlexPS,
UltraWave, Silver Network, UltraLink, and StarNet are trademarks of Senstar Corporation. Windows is a registered trademark of ®
Microsoft Corporation. Product manufactured in ISO 9001:2008 certified facility. Version: DS-J4/C-IN-R7-E-06-17

Das könnte Ihnen auch gefallen