Sie sind auf Seite 1von 2

ITEM DESCRIPTION: 16HE018 Graphite Heat exchanger

REQUISITIONER : DCBH Project


Our Requirement
Sr. No. Particulars Units
process side utility side
1 Operating Pressure kg/cm2 (g) 0.65 2.5
2 Operating Temperature °C 95 9-13
3 Design Pressure kg/cm2 (g) 0.5 5
4 Design Temperature °C 150 150
5 Process Fluid ACIDIC TOLUENE Chilled water
6 Flow Rate kg/hr 252 8845

Vapor/liquid Inlet
9 °C 95 7
Temp.

Vapor/liquid Outlet
10 °C 40 11
Temp.

11 Actual Heat Load K Cal/Hr 25339


12 Desing Heat Load K Cal/Hr 30000
Pressure Drop vendor to specify /
13 Kg/cm2 vendor to specify / 0.3
(actual/allowed) 0.05
Hydro Test Pr.
14 Kg/cm2 as per norms as per norms
(process/utility)
Size Of Hole In
15 mm 10 10
Cylindrical Block
16 No Of Holes/block vendor to specify vendor to specify

17 No. Of Block vendor to specify vendor to specify

18 Block Diameter mm vendor to specify vendor to specify

Resin Used for


19 Impregnation vendor to specify
(phenolic/PTFE)

Material of
construction

20 Block vendor to specify


21 Shell vendor to specify
22 Ends vendor to specify

23 Gasket / Sealant vendor to specify vendor to specify

24 Tie rod & nuts vendor to specify

25 LMTD 54

26 Overall HTC Kcal/hrm2C vendor to specify


28 Dirt factor Hrm2C/Kcal vendor to specify 0.0002

29 Calcuated Area M2 vendor to specify


30 Provided Area M2 10 (decided in meeting)
31 Density kg/m3 1.93 1000
32 Specific Heat Kcal/Kg-C 0.34 1
Thermal Conductivity
33 Kcal/hr-m°C 0.015 0.51
Of Utility Fluid
Viscosity Of Utility
34 Cp 0.008 0.8
Fluid
PTFE bellow process Vendor to
inlet side specify
PTFE bellow process Vendor to
Outlet side specify
PTFE bellow Utility Vendor to
inlet side specify
PTFE bellow utility Vendor to
outlet side specify
Nozzles
Vendor to
vent gas inlet
specify
uncondensed gas Vendor to
outlet specify
Vendor to
condensate outlet
specify
Vendor to
cooling water supply
specify
Vendor to
cooling water return
specify

Das könnte Ihnen auch gefallen