o D. A and C apply
46. Except for plastic piping, water piping systems may be tested with _
o A. 10 psi air pressure
o B. 50 psi air pressure
o C. 10 psi Carbon dioxide
o D. 60 psi Carbon dioxide
47. Water piping pressure shall be for a period of not less than ___
o A. 5 minutes
o B. 10 minutes
o C.15 minutes
o D. 30 minutes
48. The maximum fixture unit loading allowed on a 2-inches waste stack is
o A. 4
o B. 6
o C. 8
o D. 16
49. 3 inch horizontal drainage piping shall have a grade of slope of not less
than ___
o A. 1/4 inch per foot
o B. 1/8 inch per foot
o C. 1/2 inch per foot
o D. 1 inch per foot
50. The maximum trap loading for a 3-inch trap is
o A. 1 unit
o B. 3 units
o C. 4 units
o D. 6 units
51. The minimum sizes of vertical and horizontal drainage shall be
determined from the __
o A. Location of fixtures
o B. Type of building
o C. Total fixture units
o D. Total bathrooms
52. The minimum size trap and trap arm for a bathtub is __
o A. 1-1/2 inches
o B. 2 inches
o C. 2-1/2 inches
o D. 3 inches
53. The maximum discharge capacity (for intermittent flow only), in gallons
per minute, for one fixture unit is equal to ___
o A. 7-1/2 gpm
o B. 15 gom
o C. 30 gpm
o D. 50 gpm
54. The minimum size drain line for wall-hung urinal is __ inches
o A. 2
o B. 1-1/4
o C. 1-1/2
o D.3
55. The acceptable fitting for connecting a horizontal drain line with another
horizontal drain line is a __
o A. Sanitary tee
o B. Cross tee
o C. Combination Y and 1/8 bend
o D. Side inlet 1/4 bend
56. The clearance required in front of a 2-inch cleanout shall not be less
than __
o A. 6 inches
o B. 12 inches
o C. 18 inches
o D. 24 inches
57. The drainage line from an ejector shall be provided with a ___
o A. Backwater or swing check valve, and gate valve
o B. Backwater valve or double check valve and globe valve
o C. backwater valve, gate valve and flange
58. A horizontal drain pipe has an existing load 30 fixture units, after
connecting the discharge pipe from an ejector rated 60 gpm, the total load
on the horizontal drain pipe will be ___
o A. 90 fixtures
o B. 120 fixtures
o C. 130 fixtures
o D. 150 fixtures
59. __ are considered suds-producing fixtures
o A. Kitchen sinks
o B. Bathtubs
o C. Washing machine standpipes
o D. All of the above
60. The maximum fixture units allowed on a 4-inch horizontal drain with a
1/8 inch per foot slope is
o A. 173
o B. 225
o C. 215
o D. 256
61. A straight run of building sewer will require cleanout at intervals not to
exceed __
o A. 50 ft.
o B. 75 ft.
o C. 100 ft.
o D. 300 ft.
62. Building sewers 8 inches or larger may have a slope of not less than
___
o A. 1/16 inch per foot
o B. 1/2 inch per foot
o C. 1/4 inch per foot
63. The maximum distance between manholes shall not exceed __
o A. 50 ft.
o B. 100 ft.
o C. 200 ft.
o D. 300 ft.
64. ABS and PVC DWV piping installation shall be limited to structures of
__ *
o A. Noncombustible construction
o B. Unlimited height
o C. Two stories in height
o D. Combustible construction