Bollettino Informazione Tecnica / Technical Information Bulletin

compilato da / compiled by approvato da / approved by data / date codice / code


TIB
S. Perazio A. Niosi 26/14/2016 808659 06
classe-prodotto / class-product

d-Color MF254, d-Color MF304, d-Color MF364


Sistemi interessati / system concerned

titolo / subject

MFPB REPAIR PROCEDURE “ERROR CODES “C-D011” OR “C-D050” OR “C-FA14””

Descrizione / Description
The purpose of this document is to inform the Field about possible Error Codes “C-D011” / “C-D050” /
“C-FA14” that may occur on d-Color MF364, d-Color MF304 and d-Color MF254.
This TIB does not replace the TIB05, it is an update of the Repair Procedure described on it..

Index Part 1

A Symptom Page 3

B Cause Page 4

C Countermeasure (Temporary) Page 5

(The Index continues on next page)

1 / 13
Modulo IO-TIB-A (Liv.03)
INFORMAZIONI RISERVATE, DA DIVULGARE SOLO SU AUTORIZZAZIONE DEL “SUPPPORTO TECNICO”
CONFIDENTIAL INFORMATION ONLY TO BE DISCLOSED WITH PERMISSION FROM “TECHNICAL SUPPORT”
Supporto Tecnico / Technical Support
Bollettino Informazione Tecnica / Technical Information Bulletin

data / date codice - progr./ code - number TIB

26/04/2016 808659 06

Index Part 2
D Field Action Page 6
E Repair Procedure Page 6
1 Download the following files from FTP Server for Service Page 6
2 Preparation Work Page 7
Check if the “SATA Controller Data” can be uploaded with the
3 Page 8
following procedure
Based on the above condition “a.”, “b.”, “c.” different steps are
4 Page 9
required
Information on introduction in product line of the countermeasure
F Page 10
Firmware
G Appendix – “C-D011” – “C-FA14” detailed Error Codes Page 11
Information that are Mandatory for the replacement of the MFPB and
H Page 12
for any MFPB repaired.

2 / 13
Modulo IO-TIB-A (Liv.03)
INFORMAZIONI RISERVATE, DA DIVULGARE SOLO SU AUTORIZZAZIONE DEL “SUPPPORTO TECNICO”
CONFIDENTIAL INFORMATION ONLY TO BE DISCLOSED WITH PERMISSION FROM “TECHNICAL SUPPORT”
Supporto Tecnico / Technical Support
Bollettino Informazione Tecnica / Technical Information Bulletin

data / date codice - progr./ code - number TIB

26/04/2016 808659 06

A. Symptom:

A device, which is suffering from the problem described in this TIB, will show Error Codes “C-
D011” / “C-D050” / “C-FA14” after turning ON the Main Power Switch or when the MFP recovers
from Power Save Mode.

• C-D011 Î Hard Disk equipment not within specification


• C-D055 Î HDD Recovery Timeout
• C-FA14 Î SATA Controller in maintenance mode. (USB_SATA program is abnormally)

Important Note:

ƒ Please be aware that Error Code “C-FA14” will be shown for different problems and only
C-FA14 where the detailed Error Code leads to HDD problems is valid for this problem.
(See Appendix – C-D011 / C-FA14 detailed Error Codes at Page 11of this TIB)

3 / 13
Modulo IO-TIB-A (Liv.03)
INFORMAZIONI RISERVATE, DA DIVULGARE SOLO SU AUTORIZZAZIONE DEL “SUPPPORTO TECNICO”
CONFIDENTIAL INFORMATION ONLY TO BE DISCLOSED WITH PERMISSION FROM “TECHNICAL SUPPORT”
Supporto Tecnico / Technical Support
Bollettino Informazione Tecnica / Technical Information Bulletin

data / date codice - progr./ code - number TIB

26/04/2016 808659 06

B. Cause:

• The garbled SATA Controller Data problem has been identified as a problem in the
firmware of the SATA Controller, which causes Error Codes “C-D011” / “C-D050”.
The problem appears when the following situation happens.

ƒ The SATA Controller loads the SATA Controller Program from Flash Memory, when Main
Power Switch will be turned ON or when the MFP is recovering from Power Saver Mode.
In case that SATA Controller Data are garbled a hash error will occur during program
loading and the SATA Controller switches to run in maintenance Mode.
(Under Normal condition the SATA Controller is running in Normal Mode)
In case the Controller is running in Maintenance Mode, the Firmware treats that in this
condition a ”non-KM HDD” is connected and the Error Code will be shown.

ƒ C-D011 Î In case of detection after Main Power Switch is turned to ON


ƒ C-D055 Î In case of detection after wake up from Power Save Mode.

Important Note:
• When above condition happen, Firmware versions before of version “Gxx-54” did
show “C-FA14”

4 / 13
Modulo IO-TIB-A (Liv.03)
INFORMAZIONI RISERVATE, DA DIVULGARE SOLO SU AUTORIZZAZIONE DEL “SUPPPORTO TECNICO”
CONFIDENTIAL INFORMATION ONLY TO BE DISCLOSED WITH PERMISSION FROM “TECHNICAL SUPPORT”
Supporto Tecnico / Technical Support
Bollettino Informazione Tecnica / Technical Information Bulletin

data / date codice - progr./ code - number TIB

26/04/2016 808659 06

C. Countermeasure (Temporary):

Due to the reason that R&D and the SATA Controller Manufacture need several weeks to provide
a new SATA Controller Firmware and countermeasure with final solution, R&D released a
countermeasure Firmware “G00-A7”.
The Firmware “G00-A7” include the following procedure, which has been added in the Boot
Process. The procedure will be started when the machine Main Power has been switched On or
when it recovers from Power Save Mode.

The procedure works as follows:

1. If the MFP Controller detects that the SATA Controller started in Maintenance Mode, “C-
DA14” is shown and (USB_SATA program is abnormal) is stored in the Flash Memory
(NVRAM).

2. The procedure detects this abnormal condition and re-writes the SATA Controller Program
to correct the Program Data

3. After that, the machine will be automatically reboot to reset error code “C-FA14”.
The reboot will be initiated via the “Internal Error Reset” Function. The setting has
to be “Yes” for “Rank B” and “Rank “C”.
• Menu key Æ Counter button Æ Display keypad button Æ Stop 00 Stop 01 Æ
Digit the CE PSW and touch END button (Default PSW 9272927292729272) to
enter in Service Mode Æ System 2 Æ page 2 / 3 Æ Internal Error Auto Cancel
Æ Set both Ranks to yes:
ƒ Set “Rank B” to “YES”
ƒ Set “Rank C” to “YES”

4. If after rewritten the Program and rebooting the SATA Controller starts again in
Maintenance Mode, “1”, “2” and “3” will be executed again.

5. If after the second rewriting and rebooting, the SATA Controller ends up the third time
Maintenance Mode, the machine will stop and display Trouble Code “C-D011” at the
Control Panel. No more automatic reboot will be performed.

Note:
• If after the second re-writing and rebooting the procedure stops, control panel shows “C-
D011”, and the Main Power Switch will be switched OFF and ON again, the whole
procedure will start again. This means if you find a system which has “G00-A7” installed
which permanently shows “C-D011” the MFPB (MFP Board) has to be exchanged.

5 / 13
Modulo IO-TIB-A (Liv.03)
INFORMAZIONI RISERVATE, DA DIVULGARE SOLO SU AUTORIZZAZIONE DEL “SUPPPORTO TECNICO”
CONFIDENTIAL INFORMATION ONLY TO BE DISCLOSED WITH PERMISSION FROM “TECHNICAL SUPPORT”
Supporto Tecnico / Technical Support
Bollettino Informazione Tecnica / Technical Information Bulletin

data / date codice - progr./ code - number TIB

26/04/2016 808659 06

D. FIELD ACTION

As long as a the permanent solution with related action plan has not been provided by R&D we
recommended, in order to prevent "C-D011" / "C-D050" problem, to install the countermeasure
Firmware as below described:

1. New machine installation


2. Next machine visit
3. Machine visit because of a Service Call to fix “C-D011”, “C-D050” or “C-FA14” with detailed
code (USB_SATA Program is abnormal). In case of a Service Call following procedure has to
be done (see below section “Repair Procedure”)
a) Perform the rewriting Tool for SAT Controller
b) Update the FW with the Countermeasure, FW “G00-A7”

E. Repair Procedure

On the following steps is described the procedure to repair a MFP which shows the Error Code
“C-D011”, “C-FA14” and/or “C-D050”, currently known as “SATA Controller data corrupted”

1. Download the following files from FTP Server for Service

From the FTP Server for Service download the following files:

a) Main Firmware Version “G00-A7”

On your PC create a folder named “FW_G00-A7”, and Download into it the File
“A7PU0Y0-F000-G00-A7.exe”. The link of the FTP Server for Service is the following:

• ftp://OLI_GEN_Public:xUqsCs34f@ftp.olivetti.com/service/digital_color_products\d-
ColorMF364Series\Firmware/FW-G00-A7/

b) USB-SATA – File “A7PU0Y0-F000-GXX-A6(00).exe”

On your PC create a folder named “USB-SATA”, then Download into it the File
“A7PU0Y0-F000-GXX-A6(00).exe”. The link of the FTP Server for Service is the
following:

ftp://OLI_GEN_Public:xUqsCs34f@ftp.olivetti.com/service/digital_color_products\d-
ColorMF364Series\Firmware\FW-SATA-Issue\USB-SATA

6 / 13
Modulo IO-TIB-A (Liv.03)
INFORMAZIONI RISERVATE, DA DIVULGARE SOLO SU AUTORIZZAZIONE DEL “SUPPPORTO TECNICO”
CONFIDENTIAL INFORMATION ONLY TO BE DISCLOSED WITH PERMISSION FROM “TECHNICAL SUPPORT”
Supporto Tecnico / Technical Support
Bollettino Informazione Tecnica / Technical Information Bulletin

data / date codice - progr./ code - number TIB

26/04/2016 808659 06

2. Preparation Work:

Prepare 2 USB memories keys as below reported:

a) Firmware “G00-A7”

Click twice on File “A7PU0Y0-F000-G00-A7.exe” and unzip it.


The folder “A7PU0Y0-F000-G00-A7” is automatically created. Click on it to open the folder.
Copy the older “FW002” in the root folder of the 1st USB memory. (G00-A7)

b) USB-SATA

Click twice on the File “A7PU0Y0-F000-GXX-A6(00).exe” and unzip it.


The folder “A7PU0Y0-F000-GXX-A6(00)” is automatically created. Click on it to open the
folder.
Copy the Folder “FW0002” in the root folder of the 2nd USB memory. (USB-SATA)

7 / 13
Modulo IO-TIB-A (Liv.03)
INFORMAZIONI RISERVATE, DA DIVULGARE SOLO SU AUTORIZZAZIONE DEL “SUPPPORTO TECNICO”
CONFIDENTIAL INFORMATION ONLY TO BE DISCLOSED WITH PERMISSION FROM “TECHNICAL SUPPORT”
Supporto Tecnico / Technical Support
Bollettino Informazione Tecnica / Technical Information Bulletin

data / date codice - progr./ code - number TIB

26/04/2016 808659 06

3. Check if the “SATA-Controller Data” can be updated with the following procedure:

To upload the “SATA Controller Data” perform the following steps:

a) Take the 2nd USB Memory (USB-SATA), that contains the SATA Controller Data.
b) Turn OFF the Main Power Switch
c) Insert the “USB-SATA” USB memory into the USB Slot
d) Turn the Main Power Switch to ON while pressing the “Stop” button.
e) “Downloading” is shown during updating the “SAT Controller”
f) “SATA FW Update completed Successfully.” is shown and the Start key turns blue
when finished.

Important Note:

• If the update failed, “SATA FW Update completed Failed.” is shown and the Start
key turns Red
• If the screen shows the two grey bars for longer than 3 to 5 minutes, the SATA
Controller Data are not garbled.

g) Turn the Main Power Switch to OFF.

The following three (3) conditions can occur:

a. Condition completed successful Î SATA Controller works correctly

b. Condition hangs with two grey bars Î SATA Controller works correctly

c. Condition failed Î Replace the MFPB with a “New


MFPB”

8 / 13
Modulo IO-TIB-A (Liv.03)
INFORMAZIONI RISERVATE, DA DIVULGARE SOLO SU AUTORIZZAZIONE DEL “SUPPPORTO TECNICO”
CONFIDENTIAL INFORMATION ONLY TO BE DISCLOSED WITH PERMISSION FROM “TECHNICAL SUPPORT”
Supporto Tecnico / Technical Support
Bollettino Informazione Tecnica / Technical Information Bulletin

data / date codice - progr./ code - number TIB

26/04/2016 808659 06

4. Based on the above condition “a”, “b.”,”c.” different steps are required:

The following three (3) steps describe the operations you have to make, which are based to
the condition obtained when you uploaded the "SATA-Controller Data" to MFP.

a) When the Condition “a.” is occurred:

If the Condition “a.” is occurred, basically machine operate normally.


To prevent reoccurrence it is required to update the countermeasure Firmware “G00-A7”
as next step.

b) When the Condition “b.” is occurred:

If the Condition “b.” and trouble cause was “C-D011” and “C-D050”, replace the MFPB
with a new one.

c) When the Condition “c.” is occurred:

If the Condition “c.” is occurred, the “MFP Board” has to be replaced.

If needed, please follow the procedure described on point “F – MFPB Replacement


Procedure” starting from “Page 17”of the TIB “808659 - 05.

9 / 13
Modulo IO-TIB-A (Liv.03)
INFORMAZIONI RISERVATE, DA DIVULGARE SOLO SU AUTORIZZAZIONE DEL “SUPPPORTO TECNICO”
CONFIDENTIAL INFORMATION ONLY TO BE DISCLOSED WITH PERMISSION FROM “TECHNICAL SUPPORT”
Supporto Tecnico / Technical Support
Bollettino Informazione Tecnica / Technical Information Bulletin

data / date codice - progr./ code - number TIB

26/04/2016 808659 06

F. Information on introduction in production line of the countermeasure Firmware

The countermeasure Firmware will be installed at production line and a blue dot will be added to
the following parts:

• The Machine Serial Number Label


• The Carton Box\

Production Month Serial Number cut-in


Product Name
information information
d-Color MF364 (A7PU) May 2016 N.A.
d-Color MF304 (A7PY) May 2016 N.A.
d-Color MF254 (A7R0) May 2016 N.A.

Note:
• When the cut-in information of the Serial Number will be available this TIB will be updated with
the information.

10 / 13
Modulo IO-TIB-A (Liv.03)
INFORMAZIONI RISERVATE, DA DIVULGARE SOLO SU AUTORIZZAZIONE DEL “SUPPPORTO TECNICO”
CONFIDENTIAL INFORMATION ONLY TO BE DISCLOSED WITH PERMISSION FROM “TECHNICAL SUPPORT”
Supporto Tecnico / Technical Support
Bollettino Informazione Tecnica / Technical Information Bulletin

data / date codice - progr./ code - number TIB

26/04/2016 808659 06

G. Appendix – “C-D011” – “C-FA14” detailed Error Codes

On the table below are reported the detailed Error Codes for “C-D011” and “C-FA14” which are
related to “SATA Controller” / “HDD” Errors.

The detailed codes are divided into four groups. The detailed code is recorded based on the
condition of the SATA Controller.

• A detailed code from group A or B will be recorded, when SATA Controller starts in
Maintenance Mode and the rewriting of the SATA Controller Data was successful.
• A detailed code from group A or C will be recorded, when SATA Controller starts in
Maintenance Mode and the rewriting of SATA Controller Data failed.
• A detailed error code from group D will be recorded from errors which happen when the SATA
Controller is in normal mode.

SATA SATA
SATA Controller Maintenance Mode
rewriting rewriting D011 error if SATA Controller Data runs in Normal Mode
detected
successful failed
A B C D
0x6610 0x6650 0x6690 0x66D0 0x661B 0x661C 0x6600 0x6620 0x6640 0x6640 0x6680 0x66A0 0x66C0 0x66E0
0x6611 0x6651 0x6691 0x66D1 0x665B 0x665C 0x6601 0x6621 0x6641 0x6641 0x6681 0x66A1 0x66C1 0x66E1
0x6612 0x6652 0x6692 0x66D2 0x669B 0x669C 0x6602 0x6622 0x6642 0x6642 0x6682 0x66A2 0x66C2 0x66E2
0x6613 0x6653 0x6693 0x66D3 0x66DB 0x66DC 0x6603 0x6623 0x6643 0x6643 0x6683 0x66A3 0x66C3 0x66E3
0x6614 0x6654 0x6694 0x66D4 0x6604 0x6624 0x6644 0x6644 0x6684 0x66A4 0x66C4 0x66E4
0x6615 0x6655 0x6695 0x66D5 0x6605 0x6625 0x6645 0x6645 0x6685 0x66A5 0x66C5 0x66E5
0x6616 0x6656 0x6696 0x66D6 0x6606 0x6626 0x6646 0x6646 0x6686 0x66A6 0x66C6 0x66E6
0x6617 0x6657 0x6697 0x66D7 0x6607 0x6627 0x6647 0x6647 0x6687 0x66A7 0x66C7 0x66E7
0x6618 0x6658 0x6698 0x66D8 0x6608 0x6628 0x6648 0x6648 0x6688 0x66A8 0x66C8 0x66E8
0x6619 0x6659 0x6699 0x66D9 0x6609 0x6629 0x6649 0x6649 0x6689 0x66A9 0x66C9 0x66E9
0x661A 0x665A 0x669A 0x66DA 0x660A 0x662A 0x664A 0x664A 0x668A 0x66AA 0x66CA 0x66EA

The detailed Error Codes of « C-FA14 » which are related to HDD are in the following range :

Detailed Code Trouble Code Description


0x6001 ~ 0x6200 FA14 (Thread Software Error) HDD umount Error

11 / 13
Modulo IO-TIB-A (Liv.03)
INFORMAZIONI RISERVATE, DA DIVULGARE SOLO SU AUTORIZZAZIONE DEL “SUPPPORTO TECNICO”
CONFIDENTIAL INFORMATION ONLY TO BE DISCLOSED WITH PERMISSION FROM “TECHNICAL SUPPORT”
Supporto Tecnico / Technical Support
Bollettino Informazione Tecnica / Technical Information Bulletin

data / date codice - progr./ code - number TIB

26/04/2016 808659 06

H. Information that are Mandatory for asking the replacement of the MFPB and for any MFPB
repaired

For any MFPB that is suffering of the problem described in this TIB, you have to provide to
Olivetti HQ all the information requested on the table below.

If the MFPB needs to be replaced with a new one, it is Mandatory to provide to Olivetti the
following information:

ATTENTION:
• If you do not fill the table above with all information requested, the "MFPB Board" will
not be replaced.
• IT IS MANDATORY TO PROVDE ALL INFORMATION REQUESTED.

Information that are Mandatory for replacement of Main Board


Information Needed Answer
Reporting Date:
Product Name:
Product Serial Number:
MFPB Board Serial Number:
Error Code by using new Firmware “G00-A7”
SATA Controller Rewriting Tool used (USB-SATA) “Yes / No”:
Error Code “C-D011” occurred “Yes / No”:
Error Code “C-D050” occurred “Yes / No”:
Error Code “C-FA14” occurred “Yes / No”:
Date when Error Code occurred:
Date of Installation:
Total Mechanical Counter:

• How to detect where the Serial Number of the “MFP Board” is located:

12 / 13
Modulo IO-TIB-A (Liv.03)
INFORMAZIONI RISERVATE, DA DIVULGARE SOLO SU AUTORIZZAZIONE DEL “SUPPPORTO TECNICO”
CONFIDENTIAL INFORMATION ONLY TO BE DISCLOSED WITH PERMISSION FROM “TECHNICAL SUPPORT”
Supporto Tecnico / Technical Support
Bollettino Informazione Tecnica / Technical Information Bulletin

data / date codice - progr./ code - number TIB

26/04/2016 808659 06

Olivetti HQ, after having received all information above mentioned, will analyse the
problem and then he will inform you about the procedure that you have to follow.

The information above must be sent via the official channels at the following E-mail Addresses:

Italian Dealer:
Send the information necessary to analyse the problem to the following E-Mails:
• Concessionari-Copia@olivetti.com

And put in copy to the following E-mail addresses:

• mariapilar.clingo@olivetti.com
• stefano.perazio@olivetti.com

Agencies:

Send the information necessary to analyse the problem to the following E-Mails:
• subsidiaries-support@olivetti.com

And put in copy to the following E-mail addresses:

• marianna.ilardi@olivetti.com
• mariapilar.clingo@olivetti.com
• stefano.perazio@olivetti.com

13 / 13