Sie sind auf Seite 1von 2

12/19/2017 | Page 1 of 2

Schneider Electric USA


1415 South Roselle Road
Palatine, IL 60067
Customer Care Center: 1-888-778-2733
Web: www.schneider-electric.us

ITEM # RSB1A160RD, INTERFACE RELAY

The RSB interface relay range comprises:


1. 12 A relays with1 C/O contact , 16 A relays with 1 C/O contact and 8 A relays with 2 C/O contacts.
2. Sockets with separate contact terminals.
3. Protection modules (diode, diode + LED, RC circuit or varistor + LED). All these modules are common to all sockets.
4. A plastic maintaining clamp for all sockets.
5. Clip-in legends for the sockets.

SPECIFICATIONS | CONTACT CHARACTERISTICS | INSULATION CHARACTERISTICS

Specifications

Terminal Style PCB

Contact Configuration SPDT

Coil Voltage 6 VDC

Coil Resistance 90 Ohm

Contact Rating (Switching Current) 16 A

Storage Temperature Range -40 to 85 °C

-40 to 70 °C
Operating Temperature Range
-40 to 85 °C

Degree of Protection (Conforming to


IP 40
IEC/EN 60529)

Shock Resistance (conforming to IEC/EN


5 g-n
60068-2-27) - Opening
12/19/2017 | Page 2 of 2

Shock Resistance (conforming to IEC/EN


10 g-n
60068-2-27)- Closing

Protection Category RTI

Mounting Position Any

Sold in Lots of 10

Conforming to Standards IEC/EN 61810-1, UL 508, CSA C22-2 n° 14

CSA
Approvals
UL

Contact Characteristics

Rated Operational Current in utilisation


8A
categories AC-1 and DC-1(N/C)

Contact Materials AgNi

Maximum Operating Rate (In operating No-load: 72000


cycles/hour) Under load: 600

Switching Voltage Maximum (AC) 400 VAC

Switching Voltage Maximum (DC) 300 VDC

Switching Capacity (Minimum) 5 mA

Switching Capacity (Maximum) 4000 V·A

Mechanical Durability (In millions of


≥ 30
operating cycles)

Electrical Durability (Resistive load) (In


16 A-250 V:≥ 0.07
millions of operating cycles/hour)

Insulation Characteristics

Rated Insulation Voltage (Ui) Conforming


400 V
to IEC/EN 60947

Rated Impulse Withstand Voltage (Uimp) 3.6 (1.2/50 ps) kV