cgmp requirement of Building and Facilities (Plant Building)

1. Area for Building:


According to GMP (Pakistan published) an area of building should not less than
2000 sq. yards. However the GMP (WHO) says the building should be of suitable
size with the adequate space for future expansions.
2. Location:
The building should be located preferably in industrial area not in congested
and residential area or commercial area.
3. Surroundings
The building should be in an environment when considered with measures to
protect manufacturing process, presents, minimum risk of contamination of
materials or products, it should be away from filthy surroundings should not
connected with open sewerage, drains, public lavatory or any factory which
produces a disagreeable or obnoxious odor or fumes or large quantity of dust or
smoke which may not contaminate the drug being manufactured.
The building should be constructed according to the approved plan and the
layout should be laid in such a way as to allow the production to take place in
areas connected a logical order corresponding to the sequence of the
operations. The inter relationship of different operations should minimize the
potential for cross contamination and component mix up during storage and
interdepartmental shipping.
The passages constructed for the movements of the workers should be
constructed in such a way that dust and other contaminate may not come
inside the building.
The passages around the building should be carpeted roads or any other
material which does not allow accumulation of dust, accumulation of water and
facilitate easy cleaning.
Walls of the Building:
Walls in manufacturing areas, corridors, and packaging areas should be of
plaster finish on high-quality concrete blocks or gypsum board. The finish
should be smooth, usually with enamel or epoxy paint and projections in walls
should be avoided.

Floors:
a. The floors should be of made of chips for heavy movement, ceramic and
vinyl tiles should be avoided, however if vinyl tiles or ceramic tiles are used
they should be sealed in such a way that they should not shed particles.
b. Epoxy flooring provides a durable and readily cleanable surfaces.
Doors of the Building:
The doors of the building should be of non flammable material. While we have
doors of wooden made which are flammable.
4. Emergency Exit:
The building must have emergency exit door which is not available in present
premises.
Design of Building:
The building should be designed in such a way that it provides maximum
protection against contamination (by creating buffer sections), easy
transportation of materials, storage of materials, suitable facilities like
temperature control, humidity, light, filtered air etc, which facilitate easy
work.
Construction of Building:
The building should be constructed according to international standard which
requires building security system, absorbance of vibrations, to bear earth
quack, sound proof or if noise is produce it should be acceptable for working
conditions. Material used for building must have the quality according to the
building quality standards of materials. The building must be access able for
easy maintenance cleaning and other services.
Wash Areas:
In the wash areas the hot and cold washing facilities should be provided with
cleaning antiseptic soap, single use towels, or laser dryers. The taps used for
washing should be foot operative.
A comprehensive procedure for washing use of towels, use of water taps, use of
laser dryers should be present. Signs indicating hazards by misuse must also be
present.
Toilets
Toilets should not be present inside the building it should be around the
building. The toilets should be designed in such a way that the person can enter
only from one door and leave the toilet area after washing hands through
another door. The construction of the doors should be in such a way that the
person can only be enter from one door he cannot leave the toilet area from
the same door, for leaving the toilet area another door should be used. The
leaving door does not allow to worker to come inside the toilet. A small
washing area for washing their hands should be present in the toilet area.
A procedure should be present for the use of toilets and their sanitation.

A Suitably Designed Area Must Be Like:

Workers Entry
Separate passage should be present for the entry and for the outgoing workers
after work. However the GMP rules permit entitled entry.
Workers after use of toilets and washing their hands will enter the change area
where he will only change his uniforms keep them in lockers then he will
change his shoes wash their hands enters into the corridors by decreasing their
Bio burdens (air curtains) and in the respective production section where his
entry will be entitled, then wear the glove and mask and will enter into the
respective working section or room. Before entering he will make sure the
minimum hygienic conditions have been adopted for respected production
process.
Note:
To restrict workers movement from inside building to outside the building
canteen can be made on the top floor of the building with separate passage or
near the building.
Change Rooms:
In present change area no special rooms are present for the change of
uniforms.

Workers Hygiene:
1- A minimum requirement of workers health, hygienic protocols and clothing
for personal (uniform) should be present in written according to process
requirement must be present, ensuring clean and sanitation production of
drugs.
2- No person who affected with or is a career of a disease in communicable
form or has an open lesion on any exposed area of the body shall be employed
for area’s where a drug during any stage its production is exposed.
The minimum requirement of health should be in written and provide the
following information.
i) Pre employed medical examination
ii) Assessment of an employee’s health prior to return to his place of
employment following illness involving in a communicable disease.
iii) Action to be taken in the event of positive diagnosis of disease.
iv) Routine supervisory check of employees.
v) The hygienic program shall clearly define clothing requirements and hygienic
procedures for company personal and visitors.
vi) Where a potential for the contamination of raw material in process material
or drug exists, individuals shall wear clean clothing and protective covering.
vii) Eating, smoking, or any unhygienic practice shall not be permitted in
production areas.
viii) Requirements concerning personal hygiene, with emphasis on hand
hygiene.
ix) Requirements concerning cosmetics and jewelry worn by employees.
Flow Charts
Flow charts of following procedures must be present;
Raw Material Incoming & Packing Material, Weight to Batch Process
Batch Manufacturing processes Syrups, Capsules, Tablet, Dry Suspension etc.
Process Flow Chart of Incoming Finished Good.
Flow Chart of Workers entry to Their Work Place.
Some of the flow charts are already present but require streamlining.
According to GMP in validation flow chart must be present and verified.(Flow
charts are present but not verified & needs streamlining)
Entry of the Raw Materials:
Separate passage should be present for the entry of the raw material under
sanitation and hygienic conditions and for the leaving of rejected materials.(In
the present building there is no proper way for the entry of raw materials)
Rejected Material:
Adequate area should be present for the separation of rejected materials, the
rejected material should be disposed off as early as possible through define
procedures.
Facilities:
The building must have following systems or facilities.
1. lighting
2. Ventilation, air filtration, air heating and cooling.
3. Plumbing (water system).
4. Sewage.
5. Washing facilities.
6. Sanitation.
7. Maintenance.
The boundary wall must be present and should be constructed in such a way
that it does not allow animals inside, should have proper route for the drainage
of water and drainage passage also does not allow the animals to come inside.
Around the building if possible carpeted road should be present, doors of the
building must be sealed that does not allow the crawling animals to go inside
the building, the doors of the production areas should be constructed in such a
way that they should prevent cross contamination.
The walls must be smooth free of notches, scratches and painted with slow fire
catching paints (epoxy paints can also be used) and the floors should be smooth
may be of chips or any other material which the may does not allow to collect
the dust and the corner should be round inside the building, windows should be
minimum and should be constructed in such a way so that it should be seem to
be a part of wall, the windows present must not permit the sunlight in the
production areas.
Sanitation:
1 Non productive areas
2 Productive areas
2.1 Non sterile areas (Oral liquids, capsules, tablets etc)
2.2 Sterile Area’s (Injectabels, Injections, eye drops etc.)
A written program and procedure should be available for sanitation productive
and non productive area’s excluding sterile area’s.
ii) For the sanitation of productive area’s and non productive area’s sanitation
procedure evaluations of sanitation procedures their effectiveness use of
chemicals and their concentrations, detergents and any other materials their
effectiveness for individual production area’s should be present.
iii) List of critical points to be checked after cleaning must be present and
cleaning must be verified by an authorized person, the authorized person may
be qualified person or may be any other person trained for this purposes.
iv) Procedure for the collected wastage during cleaning and their dispose of
must be present.

Sterile Area
The sanitation of sterile area is very important they shall be cleaned prevently
and thoroughly in accordance with a written program and procedure approved
by the quality control department.
Use of Disinfectants and Detergents
Disinfectants and detergents are used for microbial count, the record of
disinfectant and detergent used their concentration, procedure for use and
control of microbial count must be present and verified.
Use of Ultraviolet Light
Ultraviolet lights are also used for microbial count but these are not alternative
of chemical use.
Fumigation
Fumigation is used to control the microbial count, the record should be kept
containing area to be fumigate, quantity of chemicals used for fumigation,
control of microbial counts and procedures must be present.
Monitoring
Disinfectant areas shall be monitored at planed intervals during operation by
mean of microbial count of air and surface, the area where an aseptic
operations are performed monitoring shall be frequent that the enviournment is
within specification. The results of monitoring are also considered when
batches are accessed for approval, air particulate matter; quality may also be
accessed evaluated on regular basis.
Sewerage:
Drains of adequate size shall be present where necessary should not permit
backflow and should be fully covered, plain to the floor which does not allow to
collect water, dust and any other material. The drain should be connected to
main drainage system if available or if not present the drain water should be
collected in a pound and re circled and sent to water channels and if after
treatment the quality permits may be used.
Lightning:
i) Layout plan should be present which should be independent of power supplies
to production instruments. The layout plan must show lighting points lines
protection equipment and earthling.
ii) The lighting wires should be according to the electric power requirement.
iii) The lighting wires must be inside the walls and the distribution boards must
be smooth and equalized with the walls so that dust may not collect on them.
iv) The lights should be concealed so that dust may not collect on them.
v) The maintenance department must have the record of total number of lights,
record of starters, chokes, manufacturer, current rating, warrantee and the
warrantee of the tube rods from the manufacturer that they does not emit
toxic rays and the evaluation for no of tube light for particular section. The
paint color, their light absorbency and reflection of light from paint must be
also considered during the planning of lights in particular section.
vi) The maintenance department must have the schedule to clean the tube
lights, fans, air conditioners, their procedure for cleaning, work instructions,
and safety equipments and their use.
vii) The maintenance department must have the record of replacement of parts
and their reasons and deviation records to use the parts other than the
approved parts.
viii) Design should include of map supply of supply lines, protective instruments
requirements of electrical supply for particular area and supplied voltage.
ix) The maintenance department, the lightning instrument should be numbered
according to the requirement of particular area’s. The lightning instrument
should be numbered and should be according to the light requirement of
particular area and should be counseled So that dust may not be collected on
them, fans and air conditions should be numbered and their cleaning
procedures and trainings record should be present. The light emitted from
lightning instruments should be non toxic and non hazards to health (warnings
for the area’s where UV lights are used and the written procedures should be
present to save from them.
x) The power supply cables should be under ground and protected from any
other damage.
xi) The lightning supply lines should be according to design

Power Supplies to Production Instruments:

àThe electrical department must have the layout plan of power supply to
different machines in different sections and must have the record of, the power
supply requirements, the supplied power, the power supply wires sizes, their
capacity (in terms of amperes & voltage) and must have the warrantee from
the manufacturer that the power cables and lines must bear the load according
to the designed.
àThe power supply panels LT or HT must be in the separated room with damage
protective instruments and must have the complete record of LT and HT
distribution connections, and the colours of different supply lines and
identification tags. The colour of different lines should be marked, in maps or
layouts with international standards.
Training:
The maintenance department should have the full instructions and written
procedures for working electrical staff on LT and HT panels with full safety
measures and safety instruments.
3.1 Security System for Premises
3.2 Entry Procedure, which includes
3.3 Identity of person (photograph, telephone no, e-mail or fax address and
other information), Searching (by hands and by instrument), time record of
entering and leaving premises, Keeping hazard materials at gate, Keeping of
cameras, Keeping of any type of weapon like knife etc, keeping of materials
like matches, cigarettes (which help in burning, CD’s and Floppies which helps
leakage of information should be kept at gate).
3.4 Security personnel
3.5 Uniforms
3.6 Uniforms with Batches & Name Strips
3.7 Weapons (Kind of weapons, their license, cleaning procedures, validation of
cleaning procedures, bullets, their manufacturer expiry dates(validity date)
3.8 Training of Security personnel ( use of weapon, training of conditions under
which it should be used, alarming use of weapons, responsibility of a person
who will order for use of weapon in conditions in which there is no order
present, extensive training to catch the persons without the use of weapon and
check of these trainings.
4 Time office building
4.1 Separate rout of incoming workers
4.2 Separate rout of outgoing workers
4.3 Record of timings, equipments and their validation & calibration
4.4 Building should be builted according to building rules and should have
temperature control faculties.
4.5 Separate toilet faculties, retiring room
4.6 Room for chief security officer (for watching workers behavior)
4.7 Separate room for keeping weapons
4.8 Room or space for keeping things caught during body searching
4.9 Searching program for surroundings of manufacturing building.
Water (Drinking Water or Potable Water):
The potable water used for drinking should be supplied under continuous
pressure through non corrosive pipes sealed joints and approved for drinking
purposes according to the FDA regulations. The design and layout of supply
lines should be present in the maintenance department. The record of checking
the potable water after every 6 moths or year must be present.
Purified Water:
Water purified by suitable means having the quality according to the standards
of BP / USP released by quality control department should be used in
pharmaceutical operations in oral dosage. The purifying water equipment
should be in separate room. The interior surfaces of the room where the
deionizer is installed (walls, floors and ceilings) should be smooth, free from
cracks and open joints, and should not shed particulate matter and should
permit easy and effective cleaning. The appearance and outlook of the
equipment should appeal the person. The following documents should be
present in maintenance department.
1- Design and layout of equipment used for purifying water
2- SOP for preparation of purified water
3- Signs indicating flow of water in the purifying water equipment
4- Design and layout of piping
5- Numbering of valve used (complete list)
6- Direction of operating the valves (by signs and arrows)
7- Presence of certificates of non toxicity of piping and materials used in
manufacture of purifying equipment including insulation which directly comes
into contact with water.
8- Presence of document validation of the above procedure
9- Approval of procedure and deviation.
10- The record of no of regenerations, the steps done by and the quantity of
the chemical used must be present, in case of change of reason, reason of
change approved by quantity change, date and time must also be present.
Posted by Niazi at 9:37 AM
Labels: cgmp requirement of Building and Facilities (Plant Building)
0 comments:

Post a Comment

Newer Post Older Post Home

Subscribe to: Post Comments (Atom)

About Me

shahid niazi
View my complete profile

Subscribe To
Atom
Posts
Atom
Comments

Blog Archive
• ► 2010 (225)
o ► October (24)
 Cleanroom Protocols
 Requirements for a Class 100 Cleanroom
 Cleanroom Entry Procedures
 Injection Molding under Cleanroom Conditions
 What is a clean room?
 Filter Bleed-Through, the Myth, the Reality and th...
 Classifications Of Clean Rooms
 Effect of protective coating of aspirin tablets wi...
 Effect of protective coating of aspirin tablets wi...
 Critical Roles of Porosity in Tableting Properties...
 An Alternative to the USP Disintegration Test for ...
 Food effects on tablet disintegration
 Tablet Disintegration and Bio-availability of Nutr...
 THE ROLE OF DISINTEGRANTS IN SOLID ORAL DOSAGE
MAN...
 Differential Response of Normal (PrEC) and Cancero...
 Delivery of Water-Soluble Drugs Using Acoustically...
 An Effective Strategy for the Synthesis of Biocomp...
 Topical Delivery of a Naproxen-Dithranol Co-drug: ...
 Cocrystalization and Simultaneous Agglomeration Us...
 In Vitro and In Vivo Anticancer Activity of a Nove...
 Quality of Original and Biosimilar Epoetin Product...
 Influence of Temperature on Solvent-Mediated Anhyd...
 Functionality Comparison of 3 Classes of Superdisi...
 Disintegration of Highly Soluble Immediate Release...
o ► September (140)
 Operations involved in tablet manufacturing | dott...
 Microscopic Wear and Corrosion Reduce the Performa...
 Application of gluconolactone in direct tablet com...
 The influence of engravings on the sticking of tab...
 Effects of surface roughness and chrome plating of...
 Modeling of adhesion in tablet compression
 Problems in tablet manufacturing
 Melt Granulation with polyethylene glycol in a Sin...
 Effervescent Dosage Manufacturing
 Lactose in Pharmaceutical Applications
 How to make tablets from potent APIs
 Roller Compaction, Granulation and Capsule Product...
 Batch production of pharmaceutical granulations in...
 Dry Granulation and Compression of Spray-Dried Pla...
 Continuous Pharmaceutical Dry Granulation And Dire...
 Moisture-Activated Dry Granulation
 The Variability of Pharmaceutical Granulation
 The effect of mill type on two dry-granulated plac...
 Precision-Granulation™ as an Alternative Fluid Bed...
 In-line process analysis of residual moisture in a...
 Visualization of a Pharmaceutical Unit Operation: ...
 Fluid Bed Granulating (Granulation)
 The Validation of Sterilization-in-Place (SIP) Pro...
 Oxoid - Assuring Microbiological Control in Pharma...
 Microbiological Contamination Control in Pharmaceu...
 Plascore Pharma Cleanroom System
o ► August (25)
o ► July (33)
o ► February (3)

• ▼ 2009 (735)
o ► November (8)
o ► October (9)
o ► September (4)
o ► August (41)
o ► July (89)
o ► June (220)
o ► May (253)
o ▼ April (50)
 Microbial production and biomedical applications o...
 Current status of the regulation for medical devic...
 Water for Instrument Processing2
 Water for Instrument Processing
 sterile area specification
 New chemical reaction that could greatly accelerat...
 Fermentation by Yeast
 Dynamic Dissolution Testing To Establish In Vitro/...
 A Review of Poloxamer 407 Pharmaceutical and Pharm...
 Viscoelastic Properties of Carbopol 940 Gels and T...
 Loading PEG-Catalase into Filamentous and Spherica...
 Pharmaceutical Quality by Design: Product and Proc...
 Drug Solubility in PEG 400/Water Cosolvent Systems...
 Inotropic Effect of Digoxin
 Design of Freeze-Drying Processes for Pharmaceutic...
 Solubilizing Excipients in Oral and Injectable For...
 ModuLab Enclosures Provide Environmental Controls
 clean room requirements
 DRY HEAT STERILIZATION
 What is the difference between an autoclave and dr...
 Physical means of achieving sterilisation
 Testing the Efficacy of Autoclaves
 Tyndallisation and Pasteurisation
 Effects of steam and dry-heat sterilization on ben...
 Biohazardous Spill in a Biological Safety Cabinet
 STERILIZATION
 Dry-Heat Sterilization
 Cleaning of Dry Heat Sterilizer
 Making Your Cleanroom Garment Program Work For You...
 Disinfecting Against Microorganisms
 medical vendor
 ISO Certification Demystified
 Advantages of Sterile Pre-Wetted Wipers
 Controlling Bacteria in Industrial Applications
 How To Minimize Contamination When Transferring It...
 Dressing For Cleanroom Success: Cutting Costs In C...
 Choosing The Right Panel Material For Your Modular...
 Preventing Cross-Contamination
 Specifying an AMC Control System
 Water – The Universal Solvent
 Drying Product in a Cleanroom Environment
 The Right Agent For Sterilization
 Validation plan for water treatment
 cgmp requirement of maintenance department
 protocols for validation
 Performance Qualifications:
 cgmp requirement of Building and Facilities (Plant...
 pharmaceutical cgmp
 Converting From an Uncontrolled Space to a Cleanro...
 Tracking Ammonia, HF, H2S, HCI, and Other Trace Ga...
o ► March (61)

• ► 2008 (19)
o ► November (13)
o ► October (6)

Das könnte Ihnen auch gefallen