1. The document provides instructions for measuring reply delay on a DME 415/435 using an oscilloscope connected to specific test points on the antenna.
2. The interrogation pulse is fixed at 50% amplitude on the oscilloscope and the reply pulse is then measured at the same point to determine the delay.
3. Changing the programmed reply delay value and re-measuring confirms that the measurement process is working as intended.
1. The document provides instructions for measuring reply delay on a DME 415/435 using an oscilloscope connected to specific test points on the antenna.
2. The interrogation pulse is fixed at 50% amplitude on the oscilloscope and the reply pulse is then measured at the same point to determine the delay.
3. Changing the programmed reply delay value and re-measuring confirms that the measurement process is working as intended.
1. The document provides instructions for measuring reply delay on a DME 415/435 using an oscilloscope connected to specific test points on the antenna.
2. The interrogation pulse is fixed at 50% amplitude on the oscilloscope and the reply pulse is then measured at the same point to determine the delay.
3. Changing the programmed reply delay value and re-measuring confirms that the measurement process is working as intended.
1. Connect Oscilloscope CH1 to MON test point AN 34
(Interrogation) 2. Connect Oscilloscope CH2 to MON test point AN 71 (Trigger). 3. Select menu Checks Standard Measurement on Monitor 1
Note: We have used Oscilloscope HM 1508 in digital
mode and we have connected test point AN 71 to Ext. Trigger of oscilloscope.
See picture below:
Set:
Interrogation Pulse level 1000 NSFA Active
All other values set to Idle!!! Select OK to activate monitor Interrogator. Interrogation pulse has to be fixed on the oscilloscope on his 50% of amplitude. Use measurement menu in oscilloscope and set reference on oscilloscope screen to 50 µs. After fixing of reference Interrogation pulse, abort Standard measurement menu. Select menu Checks Standard measurement on Antenna.
Set all values to Idle!!!
Modify Reply Delay Variation with level to Active and
set NSFA to 1000 The reply pulse will be then measured at the same point on MON (AN 34) like interrogation pulse. To provide this measurement is not necessary to switch DME to Maintenance mode. To confirm, that measurement of Reply delay was correct will be possible now to change reply delay for example to 40 µs in Transponder parameters. After that repeat measurement Reply Delay Variation with level. Now you can see, that Replay delay has changed to other value.
This method is exactly the same like monitor is doing in
automatic continuously mode. Interrogation and Reply pulse is measured at the same measuring point AN 34, because it’s detected also in the same point of DPX. See the detail block diagram of DME 415/435 prepared by Mr. Rusconi 23-03-2006.