Sie sind auf Seite 1von 1

SITI-2 SMALL HYDROPOWER PROJECT

DESIGN OF e-FLOW RELEASE ARRANGEMENT To find exact depth for a given discharge
Pipe diameter - D (m) 0.3
3
e-Flow required as per permit conditions (m /s) 0.150 Pipe length - L (m) 3.5
2
Pipe cross sectional area - A (m ) 0.0707
Data: Kutter's coefficient for steel pipe - (m1/3)
Pipe properties Entrance loss coefficient 0.012
Pipe diameter - D (m) 0.300 Coeffiecient of loss due to presence of sensor 0.5
Pipe length - L (m) 3.500 Coeffiecient of loss due to presence of flow control valve 0.25
2
Pipe cross sectional area - A (m ) 0.071 Exit loss coefficient 0.25
Coeffiecients Pipe friction loss coeffieicnt 0.5
1/3
Kutter's coefficient for steel pipe - (m ) 0.012 Sum of loss coefficients 0.312
Entrance loss coefficient 0.500 1.8124
Coeffiecient of loss due to presence of sensor 0.250
Coeffiecient of loss due to presence of flow control valve 0.250
Exit loss coefficient 0.500 H (m) V (m/s) Hf (m) Q =AV Solver
Pipe friction loss coeffieicnt 0.312 0.64551 2.122 0.4160 0.1500 0.0000
Sum of loss coefficients 1.812
Resulting Cd 0.60

H (m) V (m/s) Hf (m) Q =AV


0.60 2.046 0.3867 0.1446 Zero head loss discharge
0.70 2.210 0.4511 0.1562 0.2620
0.80 2.362 0.5155 0.1670
0.90 2.506 0.5800 0.1771
1.00 2.641 0.6444 0.1867
1.10 2.770 0.7089 0.1958
1.20 2.893 0.7733 0.2045
1.30 3.011 0.8378 0.2129
1.40 3.125 0.9022 0.2209
1.5 3.235 0.9667 0.2287

0.64551 0
0.64551 0.150

Gross haed on pipe Vs Flow through pipe 0 0.150


Siti-1 SHP e-flow arrangement 0.64551 0.150
0.240
0.230
Flow rate through pipe (m3/s)

0.220
0.210
0.200
0.190
0.180
0.170
0.160
0.150
0.140
0.130
0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60
Gross head on pipe center (m)