Sie sind auf Seite 1von 3

OBSERVATION OBSERVATION CORRECTIVE ACTION ATTACHMENTS

NO
365172 A couple of floor openings All the floor openings
found to be left idle without should be kept properly
proper covering while there covered and barricaded at
was no work which may lead all the times to prevent
to fall hazard. any kind of fall hazard

365171 Portion of the work area Proper and complete


involving the excavation and barricading along with
pipe laying activity on the relevant warning signs
road has not been provided should be provided for the
with proper and closed said work area on the road
barricading. to prevent any kind of
mishap.

365170 No blinker lights found to be Adequate number of


provided for the barricading blinker lights along with
of the excavated trench for proper and closed
pipe laying along the road barricading and reflective
signs should be provided
for the pipe laying area on
the road to ensure safe
operation.

365169 No traffic signs and hazard Relevant traffic signs as


warning signs found to be well as hazard warning
provided for the pipe laying signs should be provided
work area on the road along with hard
barricading for the pipe
laying area on the road to
ensure safe operation.

362960 No hand rails found to be Proper hand rails should


provided for the portion of be provided for the said
the access stair case at the access stair case at the grit
grit chamber area chamber area to ensure
safe access egress
360880 The toilet block meant for The toilet block should be
the use of the workers found placed on levelled and
to be placed unsafely at the stable surface to ensure
edge of the excavated area safe operation
which may fall down.
360873 Basic PPE like ear and eye All the required PPEs
protection, dust mask, etc. including dust mask,
not provided for the three safety goggles and ear
workers involved in the muff, etc. should be
hacking activity. provided for the worker
involved in hacking
activity.
360870 Floor openings found to be All the floor openings
not completely covered and should be provided with
no fall protection measures adequate covering and
provided for the workers hard barricading as
involved in hacking activities necessary along with
inside the wet well area suitable fall protection
measures to ensure safe
operation.
360868 Incomplete scaffolding Proper scaffolding
without any proper access platform completed in all
and guard rails found to be respects along with safe
used for carrying roof truss access arrangement
works at height which is not should be provided to
safe and may lead to fall ensure work at height
hazard activities in a safe manner.
358424 The floor openings inside the The subjected floor
wet well area have not been opening should be
provided with any covering provided with adequate
or barricading which may protective covering and
lead to fall hazard. hard barricading to
prevent any kind of fall
hazard.
358341 Roof truss erection work All the required safety
found to be carried out at precautions should be
height without any proper ensured before starting
fall protection measures as such work at height
one of the worker found to activities to prevent any
be working on the top of the kind of fall hazard.
roof truss without any fall
prevention measures.
357879 Various construction Proper housekeeping
materials including waste and should be done at the said
other materials found to be area and the same should
mixed up and lying in a be maintained.
scattered manner all over
near the CEB building as
poor housekeeping observed
at site.
Incomplete guard rails found Complete guard rails
357876 to be provided for the including top rail and mid
landing platform of the rail should be provided for
access stair case which may the said landing platform
lead to fall hazard. of the access stair case to
prevent fall hazard.
357874 The floor openings inside the All the floor openings
grit chamber area have not should be completely
been provided with any covered along with hard
covering or barricading barricading and warning
which may lead to fall hazard. signs to prevent any kind
of fall hazard.
365966 Sub-standard ladder made of The said sub-standard
GI pipe cut pieces found to ladder should be removed
be used inside the wet well from the site and suitable
area which may cause slip standard type of ladder
hazard due to the nature of should only be used to
GI pipes. ensure safe access egress.

365964 The vertical support for the All the supports of the
hand rail at the access stair temporary access or
case area of the grit chamber scaffolds should be firmly
found to be not properly fixed to ensure safe
fixed as it was hanging operation.

Das könnte Ihnen auch gefallen