CAESAR II 2017, Hotfix 2

(Version 9.00.00.5902)

Released: April 2017


© 2017 Intergraph Corporation. All rights reserved. Intergraph and the Intergraph logo are registered
trademarks of Intergraph Corp. or its subsidiaries in the United States and in other countries. Other
brands and product names are trademarks of their respective owners.

The content of this document is proprietary work of Intergraph Corporation, or relevant third parties,
and is protected by copyright law and international treaty. Any use, duplication, distribution or
disclosure of such, other than as specified herein, is unauthorized and in violation of applicable
copyright law and international treaty. All rights in content or materials bearing copyright notice or other
attribution of third party rights are reserved to the relevant third party. United States Government
license rights are limited to those mandatory rights identified in DFARS 252.227 -7015(b).

Intergraph may make improvements and/or changes in the products and/or the programs described in
this publication at any time without notice.

Any content or materials supplied hereunder are provided "as is ," without warranty of any kind, either
expressed or implied, including, but not limited to, any implied warranties of merchantability, fitness for
a particular purpose, or against infringement. In no event shall Intergraph be liable for any damages
arising out of, or in connection with the downloading, viewing, use, duplicati on, distribution or
disclosure of any content or material published by Intergraph, including but not limited to any direct,
indirect, incidental, special, punitive or consequential damages, or loss or corruption of data.

Some jurisdictions do not allow the exclusions or limitations set forth above, so the above may not
apply to you. The exclusions or limitations shall apply in all jurisdictions to the maximum extent allowed
by law.

Intergraph Corporation
305 Intergraph Way
Madison, AL 35758
Phone: +1.256.730.2000
Toll Free USA: +1.800.345.4856
Fax: +256.730.2048
CAESAR II 2017, Hotfix 2

CAESAR II 2017, Hotfix 2 (09.00.00.5902)


CAESAR II 2017, Hotfix 2 contains the following fixes:

• Fixed an issue in which the software performed calculations using an incorrect allowable stress
value for the IGE/TD/12 piping code under a specific circumstance. Previously, when you
analyzed a job with multiple materials and cleared the Allowable Stress check box, the software
used values from the previously defined materials and miscalculated the allowable stress for the
selected element. (TR-TX-20909)

• Fixed an issue in which duplicating an element with restraints resulted in the new element
receiving an extra restraint. Previously, if you selected the Duplicate block operation for elements
with a restraint and selected one of the Mirror options on the Block Duplicate dialog, the
software incorrectly created an extra translational skewed restraint on the new elements. (TR-TX-
20492)

• Resolved an issue with bend fitting thickness values in the CAESAR II Neutral File. Previously,
the software incorrectly converted the bend fitting thickness values when the pipe thickness units
differed from the length units. The software now converts the pipe thickness values to the
appropriate units when writing to the neutral file. (DM-TX-20973)

• Fixed an issue in which adding nozzle flexibility boundary conditions caused the software to
disable certain report options. Previously, if you analyzed a job with nozzle data, the software
disabled certain options on the Miscellaneous Data Options dialog box when creating a
Miscellaneous Data report. (TR-TX-20435)

• Fixed an issue in which the software converted certain restraint types after a neutral file
conversion. Previously, when converting an older Piping Input file to a CAESAR II Neutral File,
the software converted GUIDE restraints to LIM restraints. (TR-TX-20069)

• Addressed several performance issues that affected files with a large number of displacements.
Enhancements made to show displacement symbols on the model in CAESAR II 9.0 resulted in
increased loading times for large files with many displacements. The software has been optimized
to reduce the loading times in these files. (TR-TX-20866)

CAESAR II 2017, Hotfix 1 (09.00.00.5901)


CAESAR II 2017, Hotfix 1 contains the following fixes:

• Fixed an issue in which the software did not convert certain concentrated forces (FX) to different
units. When you converted an existing input file to a new set of units using the CAESAR II Input
File Units Conversion, the software did not convert the FX values for vectors 4 - 9 on the
Forces/Moments auxiliary tab of the Classic Piping Input. (DM-TX-19200)

• Fixed an issue in which the software would overwrite the Hanger Hardware Weight value with
the Constant Effort Support Load data when importing and exporting the CAESAR II Neutral
File. The software now writes the data to the correct location in the neutral file. (DM-TX-19202)

• Resolved an issue in which imported CADWorx .dwg graphic files did not display in CAESAR II.
Previously, an incompatibility issue with CADWorx Plant 2017 resulted in CAESAR II being
unable to display models created in CADWorx 2017. The CADWorx object enablers have been
updated and CADWorx 2017 models now display in the software. (TR-TX-19198)

• Note: This issue also affected CAESAR II 2016. Updated object enablers for CAESAR II 2016
were uploaded separately to the Smart Support website.

April 21, 2017 1


CAESAR II 2017, Hotfix 2

To Install This Hotfix Pack


1. From the CAESAR II 2017 program folder, make a backup (in a secondary location) of the
existing files to be updated by the service pack.

2. Extract the contents of the zipped file, including the program files and a read me document, to the
CAESAR II program folder, located in C:\Program Files (x86)\Intergraph CAS\CAESAR II 2017.

Note: The extracted program files overwrite the existing program files.

Files included in this hot fix: c2.exe, c2data.exe, C2Graphics.dll, C2Isogen.exe, C2S.exe,
CII_Translate.dll, CADWorxPlant.dbx, d3dcompiler_46.dll, dx9_2120.hdi, dx11_2120.hdi,
DYNOUT2.exe, DynPlot.exe, Iecho.exe, outp02.exe, pierck.exe, pierck.dll, PipingInput.dll,
prepip.exe, xx.crc, and xxc2.crc

3. Open CAESAR II 2017. Notice that the build number has changed on the main CAESAR II
window to reflect the hotfix has been applied to your version.

Note: CAESAR II hotfixes contain the cumulative of all previous hotfixes released for the specific
version of the software. If you have not installed previous hotfixes, you will get any previous ones for
the current version with this hotfix.

Contact Intergraph Technical Support at ppmcrm@Intergraph.com if you have any questions about
your version or how to apply this hotfix.

April 21, 2017 2