Sie sind auf Seite 1von 4

PILE CAPACITY

Fcu(Mpa) 50 SOIL LAYER Fs(KN/m2)


MWSL 250
SWSL 320
RUS 160

HOTEL
SOCKET LENGTH (m)
ALLOWABLE MAX DESIGN
COMPRESSION ALLOWABLE
PILE DIAMETER (mm) COMPRESSION
(SOIL FRICTION) COMPRESSION
MWSL SWSL (KN)
(KN) (KN)*

600 5.5 1 3196 3536 3000


750 5.5 3 5504 5525 5200
900 5.5 4 7510 7955 7500
1200 5.5 7 13634 14143 10000

APARTMENT-1
SOCKET LENGTH (m)
ALLOWABLE MAX DESIGN
COMPRESSION ALLOWABLE
PILE DIAMETER (mm) COMPRESSION
MWSL SWSL (SOIL FRICTION) COMPRESSION (KN)
(KN) (KN)*

600 7 0 3300 3536 3000


750 7.5 0 4420 5525 3500
900 10 0.5 7524 7955 7500
1200 7 6 13841 14143 13000

NOTE:
* THE AVERAGE COMPRESSIVE STRESS UNDER WRKING LOAD SHOULD NOT EXCEED 25% OF THE SPECIFIED WORKS CUBE
**IN OREDER TO LIMIT THE CRACK WIDTH IN PILE TO 0.2mm ,ALLOWABLE STEEL SRESS IN DIRECT TENSION SHALL NOT E
GROUND PROFILE FILL MWSL SWSL RUS
HOTEL 0-12.5 12.5-18.0 18.0-25.0 25.0-40.0
APARTMENT-01 0-8.0 8.0-18.0 18.0-23.0 23.0-40.0

AREA OF
ALLOWABLE DESIGN STEEL
TENSION TENSION (DUE TENSION)
REMARKS (KN) (KN) REMARKS BAR SIZE
(mm2)**

OK 2237 1000 OK 7692 16


OK 3853 1000 OK 7692 20
OK 5257 1000 OK 7692 20
OK 9544 4000 OK 30769 32

AREA OF
ALLOWABLE DESIGN STEEL
TENSION TENSION
REMARKS REMARKS (DUE TENSION) BAR SIZE
(KN) (KN) (mm2)**

OK 2310 500 OK 3846 12


OK 3094 1000 OK 7692 25
OK 5267 850 OK 6538 12
OK 9689 1000 OK 7692 12

F THE SPECIFIED WORKS CUBE STRENGTH AT 28 DAYS CALCULATED ON THE TOTAL CROSS-SECTIONAL AREA OF THE PILE-"BS 8004-7.4
DIRECT TENSION SHALL NOT EXCEED 130 Mpa-"BS 8007-TABLE 3.1"
SPRING
NO OF SETTELMENT STIGNESS
BARS (mm) (KN/m)

38.24 2 1598143
24.48 2 2751964
24.48 3 2503286
38.24 3 4544571 3769.9112

SPRING
NO OF SETTELMENT STIGNESS
BARS (mm) (KN/m)

33.99 2 1650000
15.66 2.6 1699863
57.79 3 2508000
67.99 3 4613714

REA OF THE PILE-"BS 8004-7.4.4.3


96.664389

Das könnte Ihnen auch gefallen