BOILER DATA SUMMARY UNIT

Pressures Kg/cm²
Steam pressure at superheat outlet
Drum operating pressure
Feed water pump outlet
Pressure part design pressure

Draft Losses - Gas Side mmwc


Furnace (1st Pass + Screen + 2nd Pass)
Across superheater
Across boiler bank
Across air heater
Across economizer
Across multi clone dust collector
Across ESP
Across ducting and dampers
Chimney turn loss
Draft at ID Fan

Draft Losses - Air Side mmwc


At plenum chamber
Across air heater
Ducting and dampers
Draft FD outlet

Velocities m/sec
Flue gas in superheater
Flue gas in boiler tank
Flue gas in air heater (avg)
Flue gas in economizer
Flue gas/hot air in ducting
Cold air in ducting

Heating Surface Details m²


Furnace, estimated project radiant surface
Superheater
Screen wall
Boiler bank
Air heater
Economizer

Steam Drum Details


Inside diameter mm
Drum cylindrical length, tan to tan mm
Nominal plate thickness mm
Dished end thickness mm
Material of Drums and ends
Furnance and water walls
Type
Size (D x W x H) mxmxm
Construction
Furnance exit temperature at MCR deg.C
Draft loss at MCR mm
Tube material
Tube OD mm
Tube thickness mm
Furnace tube pitch mm
Furnace header size (OD + Thickness) mm x mm
Header material

Superheater
Type

Primary heater coil


Tube size OD x thickness mm x mm
Tube material

Secondary heater coil


Tube size OD x thickness mm x mm
Tube material

Superheater headers
Header size , primary inlet
Header material
Header size - Primary outlet
Header material
Header size, Secondary inlet
Header material
Header size, Secondary Outlet
Header material
Type of attemperator

Boiler bank or convection bank


Type
Centre distance between tha headers
Tube size mm x mm
Tube material

Economizer
Type
Tube size mm x mm
Tube material
Header size mm x mm
Header Material

Air Heater
Location of air heater
Type
Tube size mm x mm
Tube material

Soot blowing equipment


Superheater zone'
Type of soot blower
Quantity of blowers Nos.
Convection or boiler bank
Type of soot blower
Quantity of blowers Nos.
Economizer
Type of soot blower
Quantity of blowers Nos.
Ducting
Shape of ducting
Material of construction
Plate thickness

Induced Draft Fan (ID Fan)


Number of fans per boiler
Capacity of each fan (Design) m³/sec
Temperature of flue gas Deg.C
Total Pressure (Design) mmwc
Fan speed (max) rpm
Drive kilowatt kW
Type of damper at inlet
Type of damper at outlet
Type of control

Forced Draft Fan (FD Fan)


Number of fans per boiler
Capacity of each fan (Design) m³/sec
Temperature of combustion air Deg.C
Total pressure (Design) mmwc
Fan speed (max) rpm
Drive kilowatt kW
Type of damper at inlet
Type of damper at outlet
Type of control

Secondary Air Fan (SA Fan)


Number of fans per boiler
Capacity of Each Fan (Design) m³/sec
Temperature of combustion air Deg.C
Total pressure (Design) mmwc
Fan speed (max) rpm
Drive kilowatt kW
Type of damper at inlet
Type of damper at outlet

MachanicalDust Collector, Multi cyclone


Quantity Nos.
Type
Location
Number of plate
Efficiency, % of particles greater tha 5 micron

Electrostatic Precipitator (ESP)


Quantity
Location
No. of fields
Hot gas flow - MCR m³/sec
Temperature hot gas Deg.C
Dust concentration at inlet gm/Nm³
Dust concentration at outlet mg/Nm³
Pressure drop across ESP mmwc
Power requirement of ESP kW

Ash and grit disposal system


Oil Firing Equipment
Suitable for 50% MCR
for each boiler'
Oil burners pressure jet/ steam assisted
Burner wind box
Burner train for oil firing
Burner flame scanner
Burner management system
Oil pumping ang straining unit
Instrument and control system

Wood Chip Feeders(To furnace)


Type
Number per boiler Nos.
Capacity of each feeder Kg/hr
Type of drive for feeder
Drive kW
Speed variation

Wood Chip Feed Chutes


Holding capacity Minutes
Materials of construction
Manual operated gate, rack and pinion style
Number provided

Wood chip Feeders (in live bottom silo)


Tyoe of feeder
Number of feeders
Capacity of each feeder, kg/hr
Drive of feeder
kW of feeder

Pneumatic Wood Chip Distriburors


Number per boiler Nos.
Capacity of`each boiler Kg./hr
Provided with an adjustable distributor plate

Grate
type
Number of grates per boiler
Width mm
Depth mm
Area of`grate m²
Grate heat realese kcal/m²/hr
Type of drive
Adjustable speed drive
Speed variation
Drive rating kW
Method of lubrication

Chimney
Individual chimney per boiler, Yes/No
Total number of chimneys
Height m
Diameter m
Material of construction
Material of thickness
Epoxy lined
Lightning protection, yes/no
Acess ladder
Aircraft warning light
Air duct thickness mm
Flue gas duct thickness mm
Casting and hopper thickness mm
STEAM TURBINE
PARAMETERS UNIT
Number of turbine Nos.
Type of turbine
Rated capacity MW
Superheated steam Pressure at Turbine Inlet Kg/m²(a)
Superheated steam Temperature at Turbine Inlet
deg.C
Superheated steam flow at inlet of turbine
Min. safe continuous load permissible %
Type of cooling & Type of Condenser
Exhaust Pressure Kg/m²(a)

ALTERNATOR
ratings
Power factor CosØ
Rated gross power output
Rated apparent power
Voltage
Voltage range ±
Frequency
Frequency range ±
Number of Poles
VALUE
VALUE

0.8
Min. 18 MW
Min. 225500 KV A
11 KV
10 %
50 Hz
5%
4