Sie sind auf Seite 1von 8

JUNIPER CHASSIS

CLUSTERS
Cluster Failover - Control & Fabric Links
Link Failures

There are a few possible scenarios that we may encounter with a


failure of our cluster links.

⬜ Control link fails.


⬜ Fabric link fails.
⬜ Both links fail at the same time.
Control Link Failure
Assuming our fabric link is still working. The following happens if
we lose our control link:
⬜ RG0 (Control Plane) - Secondary node will transition to a
“disabled” state.
⬜ The cluster will no longer be able to failover when required.
⬜ RG1+ (Data Plane) primary node will continue to forward user
traffic.

Control Link
Node0 - Primary Node1 - Disabled
Fabric Link
RG 0
Fabric Link Failure
Assuming our control link is still working. The following happens if we lose
our fabric link:
⬜ RG1+ (Data Plane) - Secondary node will transition to a “disabled”
state.
⬜ RTOs and session sync will not happen, failover will not be possible.
⬜ RG1+ (Data Plane) primary node will continue to forward user traffic.

Control Link
Node0 - Disabled Node1 - Primary
Fabric Link
RG 1
Control & Fabric Link Failure
If both our control and fabric links fail:
⬜ Neither node can detect each other, so they will both become
primary for all redundancy groups. This is called “split-brain”.
⬜ Unpredictable data flow, and duplicate IPs on network, this is
very bad!!

Control Link
Node0 - Primary Node1 - Primary
Fabric Link
RG 1 & 0
The “Disabled” State
If a node goes into a “disabled” state. The following steps are
needed to be performed:

1. Fix the issue. (Broken cable/hardware etc.)


2. Reboot the node.

If the issue that caused the node to go into disabled state in


the first place is not fixed, rebooting the device could lead to
split-brain scenario.
Control Link Recovery
We already know that if there is a control link failure, our
secondary node is put in a disabled state.

If we fix the problem with the control link we can configure our
node to reboot automatically, the node will reboot only if it is in
disabled state and only if it senses a working control link.

To enable the node to automatically reboot:

# set chassis cluster control-link-recovery


Verify Failover (Using IP mon.)

⬜ Unplug control & fabric cable, check the chassis


cluster status each time.
⬜ Configure control link recovery, unplug & plug back the
control link, disabled node should reboot.

■ > show chassis cluster status