UV SYSTEM REFURBISH
UV treatment chamber is made of highest quality 316L stainless steel that is corrosion resistant and very
long lasting. Internal chamber can be chemically clean. External chamber can be polished and cleaned to
shine. Existing parts like compression nuts, quartz sleeves, O-rings, lamps, UV probe are replaceable.
Normally it is the electrical aspect of the system that is giving all the problems. This is due to the corrosion
and electrical component degradation over time. Because of constant interruption from the control panel,
the UV treatment system may constantly trip.
Another common reason customers having problems with old UV system is model obsolete which render
the replacement parts like ballast no longer available for purchase. This forces the customers left with no
option but to change to new system.
Good News
Instead of buying a new UV system, Patent Licht can refurbish your old UV system by replacing a new UV
control panel and change all the UV treatment chamber parts. By doing so, you not only give a new life to
your old UV system and solve all the problems you have been facing, you save substantial cost on installing
new UV system, piping and space.
We custom-made the panel according to your existing lamp power wattage with a matching high efficient
electronic ballast or upgrade to a high power wattage lamps for an increased water flow rate. We can also
modify your system according to your requirement and needs.
Above is an old UV TOC 24 lamps system which Patent refurbished and brought it back to operation that
was beyond customer’s expectation as it was declared for scrape.
UV chamber UV chamber
covered with polished &
corrosion. cleaned of
corrosion.
Old system uses magnetic ballast New system uses electronic ballast
Old panel display small & hard to see. New panel display with big LED indicator.
Instead of buying a new UV system, Patent Licht can refurbish your old UV system by replacing a new UV control
panel and change all the UV treatment chamber parts. By doing so, you not only give a new life to your old UV
system and solve all the problems you have been facing, you save substantial cost of installing new UV system,
piping and space.
We custom-made the panel according to your existing lamp power wattage with a matching high efficient
electronic ballast or upgrade to a high power wattage lamps for an increased water flow rate. We can also modify
your system according to your requirement and needs.
Before After
Ideal Horizon UV TOC 24 lamps system - ‘PatentLicht refurbished and brought it back to operation that was beyond customer’s
expectation as it was declared for scrape.
Before
Changed old panel display to digital meter and Big LED UV lamp display
After
Before After
Replaced the missing UV probe
Before After
UV chamber polished & cleaned of corrosion.
Before After
Modified UV system from Magnetic ballast to Electronic ballast
PHOTOSCIENCE UV SYSTEM
PhotoScience UV System # 25437026 for UV lamp AY-10, 25437131for UV lamp AY-3, 25437133 for UV lamp
AY-4, 65H-19W UV lamp AZ-5 SD-10, 18537133,18537134 for UV lamp AY-6, 18537132 for UV lamp AY-7,
18537026, 18537027 for UVlamp AY-9, NPX-1 NPX-24 NPX-4NPX-41 NPX-16EL TDF6-68 65HC,
18537190EX, AUV-800 TOC, AUV-1200 TOC, AUV-1500TOC, AUV-2000 TOC, AUV-2400 TOC, AUV-2800
TOC, AUV-3200 TOC, AUV-4000 TOC,AUV-4800 TOC, AUV-6000 TOC, AUV-7200 TOC, AUC-8000 TOC,
AUV-8000TOC-SP, AUV-10ST, AUV-20 ST, AUV-40 ST, AUV-60 ST, AUV-80 ST
Before
Add in UV Meter and Hour Meter after modification
After
Discontinued and malfunction ballast Replaced with temperature sensor and Patent Ballast 5813
Removed step-down transformer Replaced with Patent Ballast which matched with UV system
Before After
UV system has been stop running for 6 years.
Before After
UV chamber polished & cleaned of corrosion.
Painting floor with epoxy.
Before After
UV system not running due to system tripped after Switch on
Before After
Changed the UV panel wiring, create each MCB for each ballast to avoid trip issue on future
After
Rusty compression nut before and after cleaning; changed fouling quartz sleeve to brand new
After
Upgrading UV Panel
Modified system by add in inline circular for safety purpose future changing lamp, add in Patent Sensor and Thermocouple
UPGRADING UV SYSTEM
From existing UV system, 75W per UV lamps, changed to 130W UV lamps. UV output and water flow rate
increased without substantial cost of installing new UV system, piping and space.
After
Changed old panel display to digital meter and Big LED UV lamp display
After
Changed Magnetic ballast to Electronic ballast, and deteriorated electrical component to brand new
After
Changed double ended UV lamp to single ended due to space constrain.
After
Lamp harness arcing between contact point and accumulation of dust and dirt particles affected wiring conductivity.
After
UV chamber polished & cleaned of corrosion.