Beruflich Dokumente
Kultur Dokumente
T.R.A.P.™
Breather Technology
For Hydraulic and Lube Oil Reservoirs
Moisture is blocked by Donaldson’s T.R.A.P. breather. In fact, it removes moisture at relative humidity levels as
low as 15%. T.R.A.P. filtration technology reacts instantly to changes in thermal conditions − blocking moisture.
T.R.A.P. breathers strip moisture vapor from intake air and releases the moisture back to the atmosphere on
the outflow cycle. The filter continuously regenerates its water holding capacity. T.R.A.P. breathers expel the
moisture back out, eliminating the need to change the breather due to water saturation … unlike desiccant
filters that require frequent change-out. T.R.A.P. breathers not only protect against moisture but also provide
advanced particulate filtration.
TRAP water before it gets in without restricting air flow, letting your hydraulic and lube oil reservoirs BREATHE.
Service Life Extended life (expels moisture and refreshes its Shorter life (due to saturation of filtering
holding capacity on each cycle). material), leading to frequent replacement.
Effectiveness Reacts instantly to conditions in the hydraulic Requires extended exposure to the air
circuit, creating a moisture barrier without stream before absorption begins.
impeding airflow. Restricts airflow.
Technology Thermally reactive barrier that removes moisture Absorbent filtering material that loses
at relative humidity levels as low as 15%. holding capacity with each cycle.
Filtration Superior moisture blocking and particulate Less effective moisture blocking and
filtration, down to 3 microns at 97% with up to particulate filtration with smaller
7x the media area. filtration area.
Other Advantages Will not freeze in winter. Subject to freezing in winter conditions.
Moisture Meets its Match
See How it Works
TRAPPED MOISTURE
2 3
D
MOIST AIR
RY
AIR
DR Y AIR
MOIST AIR
4
1
1 The circuit “breathes in” air containing 3 During the “exhalation” cycle, The T.R.A.P.
moisture vapor. breather allows unrestricted airflow outward.
2 The T.R.A.P. breather strips moisture and 4 The outflow of dry air picks up the moisture
particulate from the incoming air, allowing collected by the T.R.A.P. Breather during intake,
only clean, dry air to enter the circuit. and “blows it back out” – fully regenerating the
T.R.A.P. breather’s water-holding capacity.
Extended Range
T.R.A.P.™ Breather Technology
Donaldson T.R.A.P. breathers are available in a variety of configurations:
• ABS plastic, nylon or epoxy-coated steel construction
• NPT, BSP, UN straight thread or bayonet connections
• With and without electronic indicator options to fit a broad range of applications
Ø4.50" [114mm]
4.52" [115mm]
6.56
6.56
[166.5mm]
1 6 65
.
1.38" [35mm]
3.38
3.38
[85.8mm]
8 58
.
1" NPT
Bayonet Adaptor
Metal P565858 Top View P565857 (3/4" NPT version, optional mechanical)
P566037 (3/4" BSP version)
Ø3.18" [81mm]
1.56" [40mm]
1.70" [43mm]
2.87" [73mm]
Bayonet
3/4" NPT or 3/4" BS
1.20" [30mm]
2.41" [61mm]
1.36"
34.5
[34mm]
1.36
2.18"
55.5
Ø1.62" [42mm]
[55mm]
42.0
2.18
1.65
3.75" [95mm]
Bayonet Flange
Bayonet Flange
Bayonet Flange Gaskets
Gaskets
Mounting Hardware
Mounting Hardware 4.50" [114mm]
3.68" [93mm] 6.74" [171mm]
Technical Features
Particulate Filter
• Highly efficient pleated particulate filter
stops particle sizes down to 3 μm at 97%.
Service Interval
• Optional mechanical indicator available
Models with no indicator: change breather
every 6 months.
Electronic Indicator
• Actuated by pressure differential, flashes
red to indicate change out is needed.
Low Restriction to Air Flow Indicator setting, 1 PSID (6.9kPa).
(lpm)
• Indicator power source: 3V lithium
battery CR2032.
Pressure Drop Return (in H2O)
Standard
Mechanical Indicator Kit
(kPa)