Sie sind auf Seite 1von 2

Satisfied Customers

Defender
®
D

LPS 1223: Issue 1


Cert No. 1158a

Fast LPCB Extended


Certified Competitive
Detection Coverage

• Fast Detection • LPCB Certified • Extended Coverage • Competitive • Fast Detection • LPCB Certified • Extended Coverage • Competitive

Defender
®
D
DEFENDER YANGIN SONDURME ELEKTRONIK GUVENLIK SISTEMLER MÜH. SAN. TIC. A.S.
Şafak Mah. Akdeniz Sanayi Sitesi Abdi Yavuz Bulvarı 5009 Sok. No: 40 Kepez / Antalya / TURKEY
Antalya P : +90 (242) 346 47 37 F : +90 (242) 346 85 43 www.defender.com.tr -Years
-
SATISFIED CUSTOMER
Istanbul P : +90 (216) 348 49 58 F : +90 (216) 348 28 69 info@defender.com.tr LPS 1223: Issue 1
Cert No. 1158a
Defender
®
D
DEFENDER COOKING AREA AND HOOD EXTINGUISHING SYSTEM LOW INSTALLATION COST
The fusible detectors detect fire The system can be triggered The activation mechanism The nozzles provides wider protection area and lowest flow points against to other brands.
and trigger the system manually with manual activation trigger the system automatically The plenum nozzles A protection area is 3 m x 1,2 m but it is 2,4 m x 0,5 m in the other systems.
automatically. button by user. or manually. The duct and hood are covered by 1 nozzle. Whereas in the another systems covered by 2 nozzles.
The cooking appliances are covered by 1 nozzle. Whereas in the another systems covered by 2
1 2 3 nozzles.

As a result;
1. Defender offers low labor and piping cost due to wider nozzle protection area.
2. Low number of flow points which lead to more simple and competitive system.

LOW MAINTANENCE COST


1. System periodic maintenance is easier.
Defender can be checked easily by a gauge (green zone).
The other system can be check by a special equipment like sensitive scales.
5 5 2. The filling cost is low.
3 LPS 1223: Issue 1
Defender can be pressurized with nitrogen without any cylinder after each discharge.
Cert No. 1158a The other systems need an additional pressurized nitrogen cylinder after each discharge.
1
Defender is certified by BRE-GLOBAL LPCB.

WIDE NOZZLE COVERAGE AUTO/MANUAL PRESSURIZED


4
5

DEFENDER OTHERS ACTIVATION CYLINDER

DEFENDER PORTABLE FIRE EXTINGUISHER (F TYPE)


3,6 and 9 Liter
13F, 40F and 75F
TS 862 EN 3/7-A1 Certified
Wide Protection Area
Economical Refilling
Activation mechanism shut off FireEraser wet chemical FireEraser wet chemical
The biggest risk is the splash in the non-tested and non-certified systems.
electric, gas input and fans extinguishant is in pressurized sprayed through the nozzles to
when triggered. cylinder and discharged inside extinguish the fire immediately.
the pipes after triggering the
system.
3 4 5

www.defender.com.tr www.defender.com.tr

Das könnte Ihnen auch gefallen