Beruflich Dokumente
Kultur Dokumente
OPERATORS’ REFERENCE
GUIDE
/80,6<6
$&5
5($'(5$1'(5$6(5
23(5$725·65()(5(1&(*8,'(
315HY
)HEUXDU\
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
)25:$5'
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
Trademarks
Lumisys and ACR-2000 are the trademarks of Lumisys. All other trademarks are the property of their respective
owners, and are hereby acknowledged.
Lumisys, Inc.
225 Humboldt Court
Sunnyvale, CA 94089
(408) 733-6565
(408) 733-6567 FAX
i
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
7$%/(2)&217(176
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
)25:$5' ,
7$%/(2)&217(176 ,,
/,672)),*85(6 ,9
,1752'8&7,21 9
5()(5(1&('2&80(176 9
6$)(7<,1)250$7,21
(1*/,6+
&RQYHQWLRQV
(OHFWULFDO+D]DUGV
&RQYHQWLRQV
(WLTXHWWHVHWHPSODFHPHQWGHVpWLTXHWWHVGX$&5
3HULFRORGLVFRVVHHOHWWULFKH
0LWWHLOXQJGHU)&&
$&55($'(5,167$//$7,21
+$5':$5(,167$//$7,21
&RQQHFWLRQ'LVFRQQHFWLRQDQG3RZHU2Q2II6HTXHQFHV
ii
$&52SHUDWRU·V5HIHUHQFH*XLGH
6<67(0'(6&5,37,21
237,&6
3ULQWHG&LUFXLW%RDUGV
'DWD&RQWURO%RDUG
'DWD$FTXLVLWLRQ%RDUG
3RZHU'LVWULEXWLRQ
32:(583
23(5$7,1*7+($&55($'(5
5($',1*$3/$7(
6<67(00$,17(1$1&(
7+($&5(5$6(5
6,7(5(48,5(0(176
iii
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
/,672)),*85(6
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
iv
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
,1752'8&7,21
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
The ACR-2000 Reader is a precision instrument designed to scan phosphor plates and directly measure x-ray
exposure over a wide dynamic range with a high signal-to-noise ratio. This is accomplished by illuminating the
plate with a laser that is imaged onto the plate as the plate is moved perpendicularly to the laser. The emitted light is
collected, converted to an electrical signal and digitized to provide an 8- or 12- bit resolution image that can be
stored on disk, transferred to other computers or be processed, manipulated or printed. The ACR-2000 Eraser is
designed to efficiently erase exposed and read plates for reuse.
The ACR-2000 Reader has many features that can be controlled by software. Images may be digitized with 8 or 12
bit resolution, bytes may be reversed for viewing on other computer systems and custom tables can be utilized to
transform data. Further information regarding these features may be obtained from the documents listed below.
This document contains a basic technical overview of the ACR-2000 Reader and the ACR-2000 Eraser. The optics,
digital hardware and software subsystems are explained, as well as the subsystems’ functionality and general user
operation. Unpacking, hardware installation and system specifications are also included. This document is intended
for users who may need to understand the principles of operation and the interfacing requirements for the ACR-
2000 Reader and Eraser.
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
5()(5(1&('2&80(176
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
v
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
1
$&52SHUDWRU·V5HIHUHQFH*XLGH
1. SAFETY INFORMATION
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
1.1 English
1.1.1 Conventions
DANGER!
A DANGER! indicates that personal injury to the eyes may occur if the user
does not perform the procedure correctly.
WARNING
A WARNING indicates that personal injury may occur if the user does not
perform the procedure correctly.
CAUTION
A CAUTION indicates that damage to the product may occur if the user does
not perform the procedure correctly.
PRECAUTION
A PRECAUTION indicates that inconvenience to the user, such as loss of data,
may occur if the user does not perform the procedure correctly.
NOTE
A NOTE indicates information that should be called to the attention of the user.
Be sure to read and understand installation and operation instructions before applying power to the ACR-2000
Reader or ACR-2000 Eraser.
DANGER!
LASER LIGHT WHEN COVER REMOVED.
AVOID DIRECT EYE EXPOSURE.
2
$&52SHUDWRU·V5HIHUHQFH*XLGH
WARNING
THIS EQUIPMENT IS OPERATED WITH HAZARDOUS
VOLTAGES WHICH CAN SHOCK, BURN OR CAUSE
DEATH.
CAUTION
DOUBLE-POLE / NEUTRAL FUSING.
This equipment must be serviced by persons properly trained and certified by Lumisys.
DO NOT operate the ACR-2000 Reader with a damaged power cord. Use of an extension cord is not
recommended. This equipment must be properly grounded and power connections inspected to ensure safe
operation.
3
$&52SHUDWRU·V5HIHUHQFH*XLGH
1.2 Français
1.2.1 Conventions
DANGER!
Le message DANGER! signifie que tout manquement aux procédures de
rigueur peut entraîner des blessures oculaires.
AVERTISSEMENT
Un AVERTISSEMENT indique que toute utilisation inadéquate du système
peut entraîner des blessures corporelles.
MISE EN GARDE
Une MISE EN GARDE indique que toute utilisation inadéquate du système
peut endommager le système.
PRECAUTION
Une PRECAUTION indique que toute utilisation inadéquate du système peut
causer certains désagréments à l’utilisateur comme, par exemple, des pertes de
données.
REMARQUE
Une REMARQUE attire l’attention de l’utilisateur sur des informations
particulièrement importantes.
Veillez à lire et à bien comprendre les instructions relatives à l’installation et à l’utilisation du ACR-2000 avant de
le mettre sous tension.
DANGER!
VOUS VOUS EXPOSEZ AUX RAYONS LASER SI VOUS RETIREZ LE
COUVERCLE.
EVITEZ TOUT CONTACT OCULAIRE DIRECT AVEC LES
RAYONS.
4
$&52SHUDWRU·V5HIHUHQFH*XLGH
AVERTISSEMENT
CE SYSTEME SOUS HAUTE TENSION. DANGER DE
DECHARGES, DE BRULURES OU DE MORT.
MISE EN GARDE
PROTECTION PAR FUSIBLE NEUTRE / BIPOLAIRE.
L’entretien et les réparations de ce matériel doivent impérativement être confiés à du personnel qualifié et agréé par
Lumisys.
N’utilisez EN AUCUN CAS le ACR-2000 si vous constatez que le cordon d’alimentation est endommagé.
L’utilisation d’une rallonge est déconseillée. Ce matériel doit être correctement relié à la terre et les connexions
électriques doivent être inspectées pour garantir un fonctionnement sûr de l’instrument.
5
$&52SHUDWRU·V5HIHUHQFH*XLGH
1.3 Italiano
1.3.1 Convenzioni
PERICOLO!
PERICOLO! indica il rischio di incorrere ferite agli occhi se l’utente non
effettua il procedimento in modo corretto.
AVVERTENZA
AVVERTENZA indica il rischio di possibili lesioni se l’utente non effettua il
procedimento in modo corretto.
ATTENZIONE
ATTENZIONE indica il rischio di danni al prodotto se l’utente non effettua il
procedimento in modo corretto.
CAUTELA
CAUTELA indica la possibilità di possibili inconvenienti per l'utente, come
un'eventuale perdita di dati, se l’utente non effettua il procedimento in modo
corretto.
NOTA
NOTA indica delle informazioni che devono essere fatte presenti all’utente.
PERICOLO!
QUANDO IL COPERCHIO È TOLTO, IL RAGGIO LASER È
ESPOSTO.
EVITARE L’ESPOSIZIONE DIRETTA DEGLI OCCHI AL RAGGIO
LASER.
6
$&52SHUDWRU·V5HIHUHQFH*XLGH
AVVERTENZA
IN QUESTA ATTREZZATURA SONO PRESENTI TENSIONI
ELETTRICHE PERICOLOSE CHE POSSONO PROCURARE
SCOSSE, USTIONI O MORTE.
ATTENZIONE
FUSIBILE BIPOLARE / NEUTRALE.
La manutenzione di questa attrezzatura deve essere effettuata da una persona qualificata ed autorizzata da Lumisys.
NON usare il ACR-2000 con un cavo di alimentazione danneggiato. Non è consigliato l’uso di una prolunga
elettrica. Questa attrezzatura deve essere messa a terra e i collegamenti elettrici devono essere ispezionati in modo
appropriato per garantirne il funzionamento nella massima sicurezza.
7
$&52SHUDWRU·V5HIHUHQFH*XLGH
1.4 Español
1.4.1 Terminología
¡PELIGRO!
¡PELIGRO! indica que puede ocurrir una lesión a los ojos si el usuario no lleva
a cabo el procedimiento en la forma correcta.
ADVERTENCIA
Un ADVERTENCIA indica que usuario se puede lesionar si no lleva a cabo los
procedimientos correctamente.
AVISO
Un AVISO indica que el producto se puede dañar si el usuario no lleva a cabo
los procedimientos correctamente.
PRECAUCIÓN
Una PRECAUCIÓN indica que el usuario puede encontrarse con problemas,
tales como pérdida de datos, si no lleva a cabo los procedimientos
correctamente.
NOTA
Una NOTA proporciona información sobre la cual se debe llamar la atención
del usuario.
Asegúrese de leer y comprender las instrucciones de instalación y operación antes de encender el ACR-2000.
¡PELIGRO!
LUZ LÁSER CUANDO SE RETIRAN LAS CUBIERTAS.
EVITE LA EXPOSICIÓN DIRECTA DE LOS OJOS A LA
LUZ.
8
$&52SHUDWRU·V5HIHUHQFH*XLGH
ADVERTENCIA
ESTE EQUIPO FUNCIONA CON NIVELES DE VOLTAJE
PELIGROSOS QUE PUEDEN CAUSAR SHOCKS,
QUEMADURAS O LA MUERTE.
AVISO
FUSIBLES DE DOS POLOS Y NEUTROS.
La revisión de este equipo debe ser realizada por personas que hayan sido formadas y autorizadas por Lumisys.
NO opere el ACR-2000 con un cable de corriente que esté dañado. No se recomienda usar prolongadores
eléctricos. Este equipo debe tener una conexión adecuada a tierra y se deben inspeccionar las conexiones eléctricas
para garantizar un funcionamiento seguro.
9
$&52SHUDWRU·V5HIHUHQFH*XLGH
1.5 Deutsch
1.5.1 Definitionen
GEFAHR!
GEFAHR! weist auf eine Verletzungsgefahr für die Augen hin, sollte der
Benutzer nicht sachgemäß vorgehen.
WARNUNG
WARNUNG weist auf eine Verletzungsgefahr hin, sollte der Benutzer nicht
sachgemäß vorgehen.
VORSICHT
VORSICHT weist auf das Risiko einer Produktbeschädigung hin, falls der
Benutzer nicht sachgemäß vorgeht.
VORSICHTSMASSNAHME
VORSICHTSMASSNAHME weist auf mögliche Unannehmlichkeiten hin,
wie z.B. den Verlust von Daten, falls der Benutzer nicht sachgemäß vorgeht.
HINWEIS
Informationen, die vom Benutzer beachtet werden sollten, sind mit HINWEIS
bezeichnet.
Lesen Sie bitte die Installations- und Betriebsanleitung sorgfältig durch, bevor Sie den ACR-2000 an das Stromnetz
anschließen.
GEFAHR!
BEI ENTFERNEN DER ABDECKUNG: LASERSTRAHLEN.
NIEMALS DIREKT IN DEN LASER BLICKEN.
10
$&52SHUDWRU·V5HIHUHQFH*XLGH
WARNUNG
DIESES GERÄT ARBEITET MIT GEFÄHRLICHEN
SPANNUNGEN, DIE ZU STROMSCHLAG,
VERBRENNUNGEN ODER ZUM TODE FÜHREN KÖNNEN.
VORSICHT
ZWEIPOLIGE BZW. NEUTRALLEITER-SICHERUNG.
Dieses Gerät darf nur von Personen gewartet werden, die von Lumisys geschult und beglaubigt sind.
Den ACR-2000 niemals mit schadhaftem Stromkabel verwenden. Vom Gebrauch eines Verlängerungskabels wird
abgeraten. Das Gerät muß vorschriftsmäßig geerdet und der Netzanschluß überprüft werden, damit ein gefahrloser
Betrieb gewährleistet ist.
11
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
12
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
To fully install your ACR-2000 Reader, perform the following steps in the order indicated:
• Unpack the ACR-2000 Reader.
• Configure and install the ACR-2000 Reader hardware.
• Install and configure the Host Support Package software on the host PC (if required).
• Configure and install the Data Control Board in the host PC (if required)
• Connect the ACR-2000 Reader to the host PC.
WARNING AVERTISSEMENT
ADVERTENCIA
AVVERTENZA
EL ACR-2000 PESA MÁS DE 37 KILOS
IL ACR-2000 PESA PIÙ DI 37 KG. SONO (85 LIBRAS). SE NECESITAN DOS
NECESSARIE DUE PERSONE PER ALZARLO
E SPOSTARLO CON SICUREZZA. PERSONAS PARA MOVERLO Y
LEVANTARLO CON SEGURIDAD.
IL ACR-2000 UTILIZZA UN RAGGIO LASER
PER LA SCANSIONE. EVITARE EL ACR-2000 UTILIZA UN LÁSER PARA
L’ESPOSIZIONE DIRETTA DEGLI OCCHI AL ESCANEAR. NO MIRE DIRECTAMENTE A
RAGGIO LASER. LA LUZ DEL LÁSER.
13
$&52SHUDWRU·V5HIHUHQFH*XLGH
WARNUNG
WARNING
DISCONNECT POWER BEFORE CHANGING LINE VOLTAGES OR
FUSES.
14
$&52SHUDWRU·V5HIHUHQFH*XLGH
If the ACR-2000 is to be operated at another line voltage, the programming card must be changed. Remove the
plastic Fuse Block/Cover. Remove the voltage programming card and rotate it until the tab with the desired voltage
is pointing down, rotate the voltage indicator to point up and reinsert the card.
If the new line voltage is 230 / 240 VAC the fusing method must be changed. This is accomplished by loosening the
Phillips screw that holds the Fuse Block to the cover. Remove the Fuse Block, invert it and tighten the Phillips
screw. Install two 1.0 Amp, 250 Volt Slo-Blo fuses (Lumisys Part Number 0068-487).
Reinstall the Fuse Block/Cover and insure the indicator is pointing to the correct line voltage.
The ACR-2000 is now ready for operation.
NOTE
The fuse used in the ACR-2000 for 100 / 120 volt operation is a 1.5 Amp, 250
Volt Slo-Blo fuse (Lumisys Part Number 0065-513).
15
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
16
$&52SHUDWRU·V5HIHUHQFH*XLGH
3. SYSTEM DESCRIPTION
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
The ACR-2000 is a tabletop laser phosphor plate reader that brings together performance and durability at an
affordable price. Adaptable to most digital imaging applications, the ACR-2000 integrates easily into most
computer environments.
)LJXUH$&5
3.1 Optics
The ACR-2000 is a self-contained unit housing a laser, laser power supply, fixed optics and mirrors, a scanning
galvanometer and a light detection system.
As a beam source, the ACR-2000 uses a laser diode that generates over 15 mW of visible light. The laser beam is
directed into the focusing lens. After passing through the focusing lens, the laser beam is directed to a galvanometer
scanner. This galvanometer scanner has a precision mirror that sweeps the beam across the plate plane via a folding
mirror.
Light is collected in an integrating cylinder immediately in front of the plate plane. This collected light is detected
by a photomultiplier tube (PMT) inserted in the side of the cylinder. The PMT converts the detected light energy,
which was emitted from the storage phosphor plate, into an analog electrical signal which is processed,
logarithmically amplified, corrected for temporal fluctuation in laser output and then digitized by an A/D converter.
17
$&52SHUDWRU·V5HIHUHQFH*XLGH
)LJXUH$&52SWLFDO3DWK
18
$&52SHUDWRU·V5HIHUHQFH*XLGH
)LJXUH$&53RZHUDQG(OHFWULFDO6\VWHP
NOTE
Please refer to the ACR-2000 Service Manual, P/N 70-715, for detailed descriptions and theory of
operation for the ACR-2000 power and electrical system.
19
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
20
$&52SHUDWRU·V5HIHUHQFH*XLGH
4. POWER-UP
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
The power switch on the ACR-2000 is located in the lower left corner in the rear of the reader. See Figure 4-2.
Two LEDs, one above the other, are located on the left side. The top LED is labeled POWER, while the bottom
LED is labeled SCAN. See Figure 4-1.
When power is turned on, the POWER LED illuminates. Once the power is turned on to the reader, the PC should
be powered on, booted and the driver installed.
The ACR-2000 is now ready for use but should be allowed to warm up for 15 minutes to stabilize the electronics.
)LJXUH/('/RFDWLRQV
21
$&52SHUDWRU·V5HIHUHQFH*XLGH
)LJXUH3RZHU6ZLWFK/RFDWLRQ
22
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
23
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
)LJXUH3ODWH/RDGLQJ
5.3 Removal of Plate Jams and Using the Scan Abort Button
If a jam occurs or the user wishes to stop a scan in process he/she can press the SCAN ABORT button located near
the plate input chute. See Figure 4-1. When the SCAN ABORT button is pressed, the software driver is notified
and it will stop the plate drive motor and abort the scan. Further pressing of the SCAN ABORT button will cause a
toggle action which will start/stop the plate drive motor as well as reverse its direction. A typical sequence is as
follows:
1st press Digitization is aborted and plate drive motor stopped.
2nd press Motor is started in the reverse direction.
24
$&52SHUDWRU·V5HIHUHQFH*XLGH
WARNING
THIS EQUIPMENT EMPLOYS A LASER. LASER RADIATION MAY
BE PRESENT IF THE ACR-2000 READER IS OPERATED WITHOUT
COVERS.
AVOID LASER BEAM. DIRECT EYE EXPOSURE TO
LASER LIGHT MUST BE AVOIDED.
25
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
26
$&52SHUDWRU·V5HIHUHQFH*XLGH
6. SYSTEM MAINTENANCE
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
The outside covers of the ACR-2000 should be cleaned with a mild soap or detergent. Do not spray cleaner directly
on the ACR-2000 covers. Spray the soap or detergent on a soft, clean cloth, and then wipe down the covers.
The plastic plate support stand and exit tray should be wiped with a dry soft cloth.
There are NO operator serviceable parts within an ACR-2000. Do NOT remove either cover!
27
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
28
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
7.3 Installation
To install the unit, first make sure that it is NOT plugged in. Remove the front panel and disconnect the two cables
(the small green light and the timer pushbutton) from the printed circuit assembly near the top of the unit. Depress
the latch levers on the connectors to disconnect them. If necessary, the lamps may be temporarily removed by
releasing the plastic retaining clips on the left, lifting the metal retaining clip away from the socket about 1/8” and
then sliding the lamp to the left.
For hollow wall construction, the recommended method is to mount the unit to two #10 wood or sheet metal screws
firmly screwed through the unit’s keyhole slots into wall studs. If wall studs are unavailable, use #10 toggle or
molly-type hollow wall fasteners. For concrete walls, use an approved fastening method rated for at least 30 lbs.
each.
When the mounting is complete, reinstall the lamps if you have removed them. Be sure that the plastic retaining
clips are snapped closed. Reconnect the two cables to the printed circuit assembly and reattach the front panel.
Connect the eraser’s power entry connector to the AC wall outlet using the supplied AC power cable. Turn on the
unit’s power switch and verify that the lights turn on. Press the timer switch and observe the green light go on and
an audible alarm after 60 seconds.
29
$&52SHUDWRU·V5HIHUHQFH*XLGH
2. Under dim-light conditions, the cassette is opened, the exposed plate is removed and then placed against the
media holder located on the top of the ACR-2000 Reader.
3. The plate is then read, after which the plate drops into the catch tray on the reader.
4. The plate just read is removed from the catch tray and erased in the eraser:
• Extend the eraser slider.
• Insert the plate into the eraser slider, white phosphor side toward the eraser.
• Slide the slider (and plate) into the eraser.
• Press the timer button once.
• Wait for the beep and/or the green light to go out (60 sec).
• Remove the plate and place it into its light-tight cassette.
If a plate has been grossly overexposed, two erase cycles may be required to remove the image. If you don’t, you
may see a ‘ghost’ image on the next exposure. You can either perform two erase cycles (as described above), or,
after you press the timer button, wait 5 seconds and press it again. This will start a 120-sec erase cycle.
7.6 Maintenance
WARNING
BEFORE REPLACING ANY FUSES, DISCONNECT THE ERASER’S
AC POWER CORD.
The eraser is protected by either one or two AC line fuses, depending upon the eraser’s line voltage configuration.
110 /120 Volt One 2.5 Amp, 250 Volt Slo-Blo fuse (Lumisys Part Number 37-996)
230 / 240 Volt Two 1.25 Amp, 250 Volt Slo-Blo fuse (Lumisys Part Number 69-416-04)
The line fuses may be replaced by flipping off the power entry connector’s cover and removing the plastic fuse
block.
The eraser circuit assembly is additionally fused with a 315 mA, 250 Volt fuse (Lumisys part Number 69-416-01).
It may be replaced by unscrewing the small, round black fuse cap located next to the eraser’s power entry connector.
Lamps must be replaced only with compact fluorescent 55 W, 3000º K lamps (Lumisys Part Number 70-386).
30
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
$&5/$%(/6 /$%(//2&$7,216
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
)LJXUH$$&5/DEHOV
)LJXUH$(WLTXHWWHVGX$&5
)LJXUH$(WLFKHWWHGHO$&5
)LJXUD$(WLTXHWDVGHO$&5
$EELOGXQJ$$&5(WLNHWWHQ
31
$&52SHUDWRU·V5HIHUHQFH*XLGH
)LJXUH$/DEHO/RFDWLRQV
)LJXUH$(PSODFHPHQWGHVpWLTXHWWHV
)LJXUH$8ELFD]LRQHGHOOHHWLFKHWWH
)LJXUD$8ELFDFLyQGHODV(WLTXHWDV
$EELOGXQJ$(WLNHWWHQSOD]LHUXQJ
32
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
$&56<67(0'(6&5,37,21
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
33
$&52SHUDWRU·V5HIHUHQFH*XLGH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
$&55($'(56$03/($33/,&$7,21
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
NOTE: Not applicable to the Internal SCSI Option with the 16-bit Host Support Package.
Your ACR-2000 is supplied with a 1.44-MByte floppy disk that contains the executable code for a sample
application. This application, named "SCANFILE.EXE", will read a plate and put the data and header into an MS-
DOS file.
Before "SCANFILE.EXE" will operate, you must first install the Host Support package that is appropriate for your
digitizer, host Operating System and host /digitizer interface (SCSI or ISA).
The "SCANFILE" application may be activated from the MS-DOS command line or from batch files. The various
options which modify the way "SCANFILE" operates are controlled by using a forward slash (/) such as standard
MS-DOS commands.
The command line for "SCANFILE" has the following format:
SCANFILE [/PPL or /PPI] /PD /PF /LUT /F /DOME /AM /TIF /PMT
Options available are:
PIXELS PER LINE Default is 2048 for the ACR-2000
/PPL:x Set PIXELS PER LINE to x
x is limited to 5120 on the ACR-2000
PIXELS PER INCH Causes the driver to perform a FIXED MODE SCAN
/PPI:x Maximum PPI: ACR-2000, 10” plate = 512
PIXEL DEPTH Default is 12
/PD:12 Set PIXEL DEPTH to 12 bits/pixel
/PD:8 Set PIXEL DEPTH to 8 bits/pixel
PIXEL FORMAT Default is LSB first
/PF:LSB Set PIXEL FORMAT to LSB first
/PF:MSB Set PIXEL FORMAT to MSB first
LOOK UP TABLE Default is Normal
/LUT:N Set LUT to normal - 0.0 Optical Density = 0
/LUT:I Set LUT to inverted - 0.0 Optical Density = 4095
OUTPUT FILE Default is lsdt.img
/F:filename Set filename to ‘filename’
OUTPUT TO DOME DISPLAY
/DOME Read image from reader and output to a DOME Rx20 Display Board
AVERAGING MODE Default is OFF
/AM:OFF Set averaging mode to off
/AM:X Set averaging mode to X averaging
/AM:XY Set averaging mode to X & Y averaging
TIFF FILE OUTPUT
/TIF Set to create TIFF file output
PMT VOLTAGE Default control value is 128 for the ACR-2000
/PMT:x Set PMT voltage according to control value ‘x’
x must be in the range of 0 to 255 on the ACR-2000
If the user would like to scan a plate into a file called ‘image5.img’ using defaults, then from the MS-DOS prompt
type:
34
$&52SHUDWRU·V5HIHUHQFH*XLGH
"scanfile /f:image5.img"
This command will digitize a plate using 12 bits, 2048 pixels in width, create a Lumisys Header and write a file
named ‘image5.img’ into the current directory.