Sie sind auf Seite 1von 148

TEST & MEASUREMENT

RENTAL SOLUTIONS GUIDE 2007


VOLUME 32 ISSUE 12

>ELECTRONICS & DATA >ELECTRICAL POWER >GENERAL INDUSTRIAL >ENVIRONMENTAL >CALIBRATION


TEST & MEASUREMENT RENTAL SOLUTIONS
From 1
Specialised
day to
equipment
rental long
term

Rental Convenient
Purchase office
Option locations

Delivery &
setup

Expert Calibration
advice services
TechRentals Information ii
Office Locations iv
Quick Find Solution Guide vi

>Electronics & Data 1


General Electronic Test Equipment 2
RF & Microwave 13
Low Frequency 26
TV Test Equipment 27
Data, Network
WELCOME & Telecommunications 28
Cable/Pipe Testers & Locators 36
We are pleased to bring you the 2007 edition of our
Rental Solutions Guide, showcasing our extensive
inventory of test and measurement equipment covering
>ELECTRICAL POWER 39
Data Communications, RF Telecommunications, Magnetic Field Meters 40
Electrical Power, Environmental and General Industrial. Insulation & Resistance Testers 41
Power Quality Analysers 48
TechRentals have been helping solve test and Projection Relay Testing Systems 57
measurement problems for over 32 years and in the AC/DC Hi Pot Testers 59
past 12 months our organisation has seen significant Electrical Transducers 60
changes, which have only enhanced our ability to assist. Current Injectors - Primary & Secondary 65
New offices in regional Australia in places like Devonport Power Line Conditioners & UPS 66
and Karratha, plus new locations in New Zealand AC Power 68
and Malaysia are helping us deliver our solutions
to the world.
>GENERAL
This new edition of our guide includes numerous
new products and models, also highlighting our
INDUSTRIAL 69
Data Acquisition & Recording 70
equipment calibration capabilities via our sister
Physical Measurement 77
company VMS; Australia’s leading group of NATA
Non-Destructive Testing 88
certified calibration laboratories.
General Industrial 94
We look forward to assisting you with your test and Temperature
measurement needs and hope you will find this guide & Humidity Measurement 102
a useful resource. Security Equipment 106

>ENVIRONMENTAL 109
The TechRentals Team Flow Meters 110
Air Conditioning
& Air Quality - HVAC & IAQ 113
Occupational Health & Safety 119
Gas Analysis & Monitoring 123
General Environment 128
Laboratory 131

>CALIBRATION 133
General Index 135


TECHRENTALS
providing solutions
For 32 years, TECHRENTALS has been providing rental
solutions across Australasia. When you need to test,
measure or record, we will assist with expert advice, flexible
rental options and the right technology to get the job done.
When you need the job done right, first time, talk to us.

Why YOU SHOULD usE TECHRENTALS


convenient locations
Our customers have access to over 30 TR Corporation locations across Australia,
New Zealand and Malaysia. Locations range from small technical offices in remote
areas such as Karratha in the mining hub of Western Australia to sophisticated
calibration laboratories in Sydney and Brisbane, and our fully equipped TR Corporation
headquarters in Melbourne.
Vast inventory of specialised equipment
With more than 10,000 items in stock, we’re bound to have the gear you need, no
matter what your industry or project. New products are continually being added to our
inventory as technology evolves. Local government regulations may apply to the use of
some equipment in this catalogue, please contact your local office for more information.
The latest products from world class brands
We stock the latest gear from leading manufacturers including FLUKE, AGILENT,
Hioki, ANRITSU, MEGGER, YOKOGAWA and more.
Expert advice
Our team of technical sales people are highly experienced, most with extensive industry
backgrounds. They’re friendly, reliable and knowledgeable with a “can do” attitude.
Simple quoting
Our rapid quoting system means you are only a phone call or “mouse click” away.
Get online and select the equipment you need, or call and discuss your specific
requirements with our team for a quick and accurate estimate.
Flexible rental terms
Whether it’s for a day, a week, a year, or you wish to rent-to-own, TECHRENTALS can
assist. And if your project is extended, it’s no problem. Simply call and we’ll amend the
rental contract.
Responsive delivery & setup
You need equipment fast and at the right place, at the right time, and ready to go.
Equipment is delivered in purpose-built protective containers, in tiptop condition and
with easy to understand instructions.
Options
Other options are available to complement your rental needs including data download,
trained operators to manage the task for you, customised equipment programming and
even total asset management.
No risk guarantee
And if the unusual occurs and the gear isn’t up to the job, return it within 24 hours to
receive a refund on the rental charge.
Part of TR Corporation
In 2005, TechRentals became part of a larger family with the formation of TR
Corporation. Each subsidiary is a leading brand offering a specialised technology
solution for industry. Our group capabilities now include radio communications, audio
visual & business equipment, calibration, wireless connectivity solutions and mining
communications. Our customers range from mining companies in Poland and Chile
to a small electrical contractor in Christchurch, New Zealand - making us a truly global
technology supplier.

ii
WHY BUY WHEN YOU CAN RENT?
Delivering Why YOU SHOULD rent
benefits Financial benefits
Conserve your capital: Industrial equipment is expensive and can spend much
Whether you’re part of of its time unused, collecting dust and delivering no return on investment. By renting
a major multinational the equipment that you only need occasionally, you can release your organisation’s
or a small-to-medium capital to invest in other parts of the business.
enterprise, equipment Recover your costs: Generally, rental payments are fully tax deductible, and
rental makes good the expense can be recouped far quicker than tax allowances for ongoing asset
depreciation.
business sense offering
Streamline your accounts: Equipment is often required for a particular client,
a range of economic and project or location. Renting allows you to control your financials more effectively and
practical benefits. simplifies the process of allocating costs to internal departments or third-parties.
Avoid the headaches and Wipe out running costs: The expense of maintaining, calibrating and
talk to us. warehousing equipment can be high. By renting equipment, you avoid these costs and
potentially free-up valuable space within your premises.
Operational benefits
Try before you buy: It’s not always clear which equipment make and model will
fulfil your requirements. A short term rental can give you the hands-on experience you
need to guide purchase decisions.
ECONOMICAL Keep up with the times: Businesses are constantly evolving to keep pace with
new technologies. Rental allows you to update your equipment in line with other
FLEXIBLE business and industry changes and avoid the risk of accommodating costly dinosaurs.
ACCESSIBLE Cater to the unexpected: At peak periods or when essential equipment breaks
Free up capital down, rental can put the necessary equipment in your hands ensuring seamless
operations.
Recover costs Refer to the experts: Should you experience difficulties with rented equipment,
more quickly it’s not your problem. Simply call TechRentals for free professional equipment advice
Control costs and support.
more efficiently
Eliminate running costs
Conduct product
research before
purchases Option to own
Apply new technologies TechRentals offers approved business
& avoid obsolescence customers a unique rental solution
with option to own schemes.
Respond to
Whether it’s the latest power analyser
sudden demands or a humidity chamber, the option of
Seek help from ownership offers flexibility should a
the experts stopgap measure turn into a long term
or permanent need.
After a mutually agreed minimum
rental period (typically 12 months),
the equipment may be purchased
by paying an amount equal to one
month’s rental. After a specified
number of payments, the equipment
is yours!
For more information about option to
own schemes, please call your local
TechRentals office.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my iii
locations
australia
With locations across Adelaide
81-83 Stephens Avenue
Perth
122 Kewdale Road
Australia, New Torrensville South Australia 5031 Kewdale Western Australia 6105
Zealand and Malaysia, P +61 8 8302 8800 P +61 8 9441 3900
TECHRENTALS have F +61 8 8302 8899 F +61 8 9441 3999

all your Test and


Brisbane Port Melbourne
Unit 1 46 Longland Street Unit 11 484 Graham Street
Measurement problems Newstead Queensland 4006 Port Melbourne Victoria 3207
covered P
F
+61 7 3850 7700
+61 7 3850 7799
P
F
+61 3 9896 3000
+61 3 9896 3099
Darwin Sydney
Unit 3 101 Coonawarra Road Metro Centre Unit 13
Winnellie Northern Territory 0820 38-46 South Street
P +61 8 8947 2860 Rydalmere New South Wales 2116
F +61 8 8947 2901 P +61 2 9933 1100
Devonport F +61 2 9933 1199
53 Don Road Townsville
Devonport Tasmania 7310 Unit 8 15-17 Castlemaine Street
P +61 3 6422 6000 Kirwin Queensland 4817
F +61 3 6424 3994 P +61 7 4773 7788
Gold Coast F +61 7 4723 5397
103-105 Spencer Road
Nerang Queensland 4211 vms - calibration,
P +61 7 5596 3451 repair & service
F +61 7 5596 4119 melbourne
Karratha 6 Joseph Street
33B Gawthorne Drive Blackburn North Victoria 3130
Karratha Western Australia 6714 P +61 3 9896 3000
P +61 8 9185 6871 F +61 3 9896 3099
F +61 8 9441 3999 Coopers Plains
Melbourne Unit 1&4 30 Lensworth Street
6 Joseph Street Coopers Plains Queensland 4108
Blackburn North Victoria 3130 P +61 7 3344 1866
P +61 3 9896 3000 F +61 7 3344 1744
F +61 3 9896 3099 Milperra
Newcastle Unit 34 244 Horsley Road
Unit 2 1 Hartley Drive Milperra New South Wales 2214
Thornton New South Wales 2322 P +61 2 9771 9300
P +61 2 4966 5910 F +61 2 9711 9600
F +61 2 4966 3586

iv
LOCATIONS
new zealand MALAYSIA
AUCKLAND Kuala Lumpur
669 Great South Road 38 Jalan PJS 11/3 Bandar Sunwa
Penrose Auckland New Zealand 46150 Petaling Jaya
P +64 9 589 2030 Selangor Darul Ehsan Malaysia
F +64 9 589 2031 P +60 3 5632 1135
HAMILTON F +60 3 5632 5409
4/11 Pukete Road Penang
Te Rapa Hamilton New Zealand B-4-23 Krystal Point
P +64 7 849 0674 303 Jalan Sultan Azlan Shah
F +64 7 849 0676 Sungai Nibong
WELLINGTON 11900 Penang Malaysia
71 Hutt Road P +604 642 6318
Wellington New Zealand F +604 642 2035
P +64 4 384 4833
F +64 4 384 4677
CHRISTCHURCH
540 Wairakei Road
Christchurch New Zealand
P +64 3 338 1188
F +64 3 338 7100

other tr corporation
locations in new zealand:
bearcom
communications
Auckland
Hamilton
Wellington
Christchurch
VIDCOM
AUDIO VISUAL
Auckland
Tauranga
Hamilton
Rotorua
Christchurch
Queenstown
Dunedin

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 
QUICK FIND SOLUTION GUIDE
Agriculture maintenance
& management
endoscopes 79 cable pipe testing & location 36
chemical analysis 131 gas analysis & monitoring 123 current injection 64
data logging 70 hardness testing 93 data logging 70
environmental testing 123 humidity & moisture measurement 105 dc power supplies 7
humidity measurement 113-114 light & UV measurement 119 digital storage oscilloscope 2
light & UV measurement 119 liquid & gas flow measurement 110 electrical calibrators 9
liquid & gas flow measurement 110 load measurement 85 electrical transducers 60
microscopes 82 noise measurement 120 field strength measurement 19
pressure measurement 77, 83 non-destructive testing (NDT) 88 general electrical testing 63
temperature measurement 102 pressure measurement 82-83 high voltage testing 4, 59
weather recording 118 security equipment 106 instrumentation amplifiers 73
Air conditioning & refrigeration -
temperature/humidity/barometric insulation testing 40
maintenance recorders 102 magnetic field measurement 40
air conditioning system balancing 118 thermal imaging cameras 104 multimeters & electrometers 5
air flow measurement 113-114 vibration measurement 88 power transformers 67
air quality testing 113-114 weather recording 118 temperature measurement 102
data logging 70 Business & office equipment thermal imaging cameras 104
dust detection 113-114 ac generators & UPS 66 voltage current recording 76
gas analysis & monitoring 123 network test equipment 29 Emergency services
gas leakage detectors 118 security equipment 106 ac generators & UPS 66
humidity measurement 77, 83 Chemical analysis ac power sources/inverters/
liquid & gas flow measurement 110 air quality measurement 113-114 generators 68
noise analysis 120 ground water logging 128 air flow measurement 113-114
pressure measurement 82-83 salinity testing 128 air quality 113-114
temperature measurement 102 spectrophotometers 131 cable pipe testing & location 36
temperature/humidity/barometric water quality testing 128 data logging 70
recording 102 Data communications endoscopes 79
vibration measurement 88 ac generators & UPS 66 environmental - testing 123
Automotive engineering & design dc power supplies 7 gas analysis & monitoring 123
air flow measurement 113-114 fibre optics cable testing & splicing 33 high speed video capture 82
air quality testing 113-114 LAN analysis and management 29 light & UV measurement 119
data logging 70 LAN cable testing 32 microscopes 82
dc power supplies 7 WAN analysis & management 31 noise & vibraton analysis 120
electrical insulation testing 41 Defence police fire & emergency non-destructive testing (NDT) 88
endoscopes 79 ac generators & UPS 66 RF & microwave testing equipment 13
force gauges 84 ac power sources/inverters/ sound signal analysis 119
gas analysis & monitoring 123 generators 68 spectroscopy 131
high speed video recording 82 air flow measurement 113-114 temperature measurement 102
humidity measurement & recording 102 air quality 113-114 thermal imaging cameras 104
instrumentation amplifiers 73 cable pipe testing & location 36 TV test equipment 27
light & UV measurement 119 data logging 70 weather recording 118
liquid & gas flow measurements 110 endoscopes 79 Environmental testing
microscopes 82 environmental - testing 123 air flow measurement 113-114
noise analysis 120 gas analysis & monitoring 123 air quality measurement 113-114
non-destructive testing (NDT) 88 high speed video capture 82 data logging 70
pressure & vacuum light & UV measurement 119 electrochemistry 128
measurement 82-83 microscopes 82 gas analysis & monitoring 123
tachometers & stroboscopes 78 noise & vibraton analysis 120 humidity & moisture measurement 105
temperature measurement non-destructive testing (NDT) 88 light & UV measurement 119
& recording 102 sound signal analysis 119 liquid & gas flow measurement 110
thermal imaging camera 104 spectroscopy 131 noise & sound 120
vibration measurement 88 temperature measurement 102 spectroscopy 131
Building & construction thermal imaging cameras 104 temperature measurement 102
ac power sources/inverters TV test equipment 27 temperature/humidity/barometric
/generators 68 weather recording 118 recorders 102
air flow measurement 113-114 Education thermal imaging cameras 104
air quality testing 113-114 security & surveillance equipment 106 vibration analysis 88
cable & pipe location 36 Electrical – industrial & domestic water quality testing 128
cable integrity testing 36 ac generators & UPS 66 weather recording stations 118
concrete testing 90-93 ac power analysis & recording 40 Event management
distance measurement 78 ac power sources/inverters/ metal detectors 107
electrical insulation testing 41 generators 68 security & surveillance 106

vi
QUICK FIND SOLUTION GUIDE
Food manufacturing noise & sound analysis 120 strip chart recorders 76
air quality monitoring 113-114 OH&S & environmental compliance tachometers/stroboscopes 78
endoscopes 79 testing 122 tape recorders 76
high speed video capture 82 vibration analysis 88 temperature measurement 102
humidity measurement & logging 102 water quality measurement 128 temperature/humidity recorders 102
metal detectors 106 IT departments thermal imaging cameras 104
moisture meters 105 ac generators & UPS 66 vibration analysis 88
process control test equipment 94-95 air conditioning testing 113-114 Marine
scales & balances 87 air flow measurement 113-114 dc & ac power testing 40
temperature measurement cable location 36 endoscopes 79
& logging 102 data comms test equipment liquid & gas flow measurement 110
water quality testing 128 – LAN/WAN 31 non-destructive testing (NDT) 88
Gas industry security & surveillance equipment 106 see ‘general electronics test equipment’
cable pipe testing & location 36 temperature measurement Mining & exploration
data logging 70 & recording 102 ac generators & UPS 66
gas analysis & monitoring 123 Local government air flow measurement 113-114
high speed video capture 82 ac generators & UPS 66 air quality measurement 113-114
humidity & moisture measurement 105 air flow measurement 113-114 cable pipe testers & locators 36
liquid & gas flow measurement 110 air quality testing 113-114 data logging 70
non-destructive testing (NDT) 88 cable pipe testing & location 36 dc power supplies 7
OH&S & environmental testing concrete testing equipment 90 distance measurement & surveying 78
- general 122 data logging 70 electrochemistry 128
pressure vacuum gauges electrical insulation testing 41 endoscopes 79
& recorders 82-83 electrical testers 63 force measurement 84
spectroscopy 131 electrochemistry 128 gas analysis 123
thermal imaging cameras 104 gas analysis 123 high speed video capture 82
voltage current recording 76 LAN analysis & monitoring 29 humidity & moisture measurement 105
General electronics test equipment LAN/WAN analysers 31 inclinometers 84
data logging 70 light & UV measurement 119 light & UV measurement 119
dc power supplies 7 magnetic field meters 40 liquid & gas flow measurement 110
digital storage oscilloscopes 2 noise & sound analysis 120 load measurement 85
distortion analysers 26 OH&S & environmental equipment 122 Logic analysers & testers 10
electrical calibrators 9 temperature measurement 102 memory recorders 73
EMC test equipment 21 thermal imaging cameras 104 microscopes 82
field strength meters & antennas 19 vibration analysis 88 noise & sound analysis 120
frequency counters 12 WAN analysers 31 non-destructive testing (NDT) 88
frequency response analysers 10 water quality testing 128 OH&S & environment compliance
function generators 8 Manufacturing & process industry testing 122
instrumentation amplifiers 73 ac generators & UPS 66 power analysis & recording 40
LCR meters 9 cable pipe testing & location 36 pressure & humidity
LF signal generators 26 data logging 70 measurement 77, 83
logic/analysers/testers 10 distance mesurement 78 pressure vacuum gauges
memory recorders 73 endoscopes 79 /recorders 82-83
multimeters & electrometers 5 gloss mesurement 90 protection relay testing 57
non-storage oscilloscopes 3 hardness testing 93 RF amplifiers 13
probes & accessories 4 high speed video capture 82 RF signal generators 13
PROM programmers 10 humidity & moisture measurement 105 RF sweep generators 13
pulse generators 9 inclinometers 84 spectroscopy 131
strip chart recorders 76 light & UV measurement 119 strip chart recorders 76
tape recorders 76 liquid & gas flow mesurement 110 telecommunications testing 21
TV test equipment 27 materials testing 86, 128, 131 temperature measurement 102
ultrasonic baths 100 memory recorders 73 temperature/humidity/barometric
voltage current recorders 76 microscopes 82 measurement 102
Health & safety noise & sound analysis 120 thermal imaging cameras 104
air flow measurement 113-114 non-storage oscilloscopes 3 vibration & alignment analysis 88
air quality measurement 113-114 OH&S & environmental - general 122 weather monitoring & recording 118
data logging 70 position transducers 84 Non-destructive testing
electrical insulation testing 41 pressure & humidity acceleration measurement 88
electrochemistry 128 measurement 77, 83 cover meters 92
gas analysis & monitoring 123 pressure vacuum measurement 82-83 gloss measurement 90
light & UV measurement 119 PROM programmers 10 hardness testing 93
magnetic field measurement scales & balances 87 liquid & gas flow measurement 110
– Gauss Tesla 40
AUSTRALIA NEW ZEALAND MALAYSIA
1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my vii
QUICK FIND SOLUTION GUIDE
shock testing 88 power analysis & recording 40 Telecommunications

thickness measurement 90 protection relay testing 57 distortion analysers 26


vibration measurement 88 strip chart recorders 76 fibre optics testing & splicing 33
Occupational health & safety tachometers/stroboscopes 78 frequency counters 12
air flow measurement 113-114 temperature/humidity/barometric LAN/WAN analysis 31
air quality measurement 113-114 measurement 102 logic analysers & testers 10
data logging 70 thermal imaging cameras 104 pulse generators 9
electrical insultation testing 41 vibration & alignment analysis 88 RF & microwave 13
electrochemistry 128 voltage current recorders 76 RF amplifiers 13
gas analysis & monitoring 123 weather monitoring & recording 118 RF signal generators 13
light & UV measurement 119 Quality control RF sweep generators 13
magnetic field measurement see ‘manufacturing & process industry’ section WAN analysers 31
– Gauss Tesla 40 Refrigeration Training

noise & sound analysis 120 see ‘air conditioning & refrigeration’ section security & surveillance 106
OH&S & environment compliance Retail Transport

testing 122 security & surveillance equipment 106 automotive general testing 90
vibration analysis 88 RF & microwave data logging 70
water quality measurement 128 communications test sets 21 dc power supplies 7
Petrochemical EMC test equipment 21 distance measurement 78
data logging 70 field strength meters & antennas 19 endoscopes 79
electrochemistry 128 filters 26 load measurement 85
force measurement 84 frequency counters 12 noise & sound analysis 120
gas analysis & monitoring 123 logic analysers & testers 10 non-destructive testing (NDT) 88
high speed video capture 82 modulation meters 20 scales & balances 87
liquid & gas flow measurement 110 power meters 22 thermal imaging cameras 104
load measurement 85 RF amplifiers 13 vibration & alignment analysis 88
memory recorders 73 RF signal generators 13 Travel & leisure

microscopes 82 RF sweep generators 13 metal detectors 106-107


non-destructive testing (NDT) 88 spectrum analysers - high frequency 14 security equipment 106
pressure & humidity telecommunications testing 21 Water wastewater & plumbing
measurement 77, 83 TV test equipment 27 data logging 70
pressure vacuum gauges Road rail & civil construction distance measurement & surveying 78
/recorders 82-83 ac power sources/inverters electrochemistry 128
strip chart recorders 76 /generators 68 endoscopes 79
tachometers/stroboscopes 78 air flow measurement 113-114 gas analysis & monitoring 123
temperature measurement 102 air quality measurement 113-114 inclinometers 84
thermal imaging cameras 104 cable pipe testing & location 36 liquid & gas flow measurement 110
vibration & alignment analysis 88 concrete testing equipment 90-92 pipe locators 36
water quality measurement 128 dc power supplies 7 water quality testing 128
Plumbing & gasfitting distance measurement & surveying 78 Workplace environment
see ‘water waste water & plumbing’ section electrochemistry 128 air flow measurement 113-114
Power generation & distribution force measurement 84 air quality measurement 113-114
cable pipe testers & locators 36 gas analysis & monitoring 123 data logging 70
combustion gas analysis hardness testers 93 electrical insulating testing 41
& monitoring 124-125 inclinometers 84 electrochemistry 128
current injectors 64 load measurement 85 gas analysis & monitoring 123
data logging 70 magnetic field measurement
distance measurement & surveying 78 – Gauss Tesla 40
endoscopes 79 noise & sound analysis 120
force measurement 84 non-destructive testing (NDT) 88
hi pot testing 59 power analysis & recording 40
high speed video capture 82 vibration & alignment analysis 88
humidity & moisture measurement 105 water quality testing 128
inclinometers 84 weather monitoring & recording 118
insulating testing 41 Security & crowd crontrol
LCR meters 9 bug detectors 106
liquid & gas flow measurement 110 CCTV 106
load measurement 85 metal detectors – person
magnetic field measurement & walk thru 106
– Gauss Tesla 40 surveillance equipment 106
noise & sound analysis 120 thermal sensing cameras 104
non-destructive testing (NDT) 88

viii
electronics & data
general electronic test equipment
Digital Storage Oscilloscopes

Channels Bandwidth
Model Sampling Features Interfaces
(MHz)
TEK,TDS2014 Colour, automatic measurements. TDS2CMA,
100 1GS/s
TDS,TPS2014 Colour, battery operated, automatic & power measurements GPIB, RS232

4 Inbuilt printer and FDD. FFT. 1.2Mb memory (2, 4 ch).


YEW,DL1540L 150 200MS/s GPIB
FFT and GO/NOGO waveform functions.
TDS2CMA,
TEK,TDS2024 200 2GS/s Colour, automatic measurements, FFT
GPIB, RS232
Centronics,
TEK,TDS3052/B 2 Extensive automatic measurements. Inbuilt FDD.
RS232, GPIB
500 5GS/s
TEK,TDS3054 Extensive automatic measurements. Inbuilt FDD. Centronics,
4
TEK,TDS3054B Some assets include FFT, advanced trigger modules. RS232, GPIB

TEK,THS720A 100 500MS/s AC/DC battery portable. Multimeter functions.

TEK,THS730A 2 AC/DC battery portable. Multimeter functions.


FLU,199C- 200
2.5GS/s Colour, DMM, auto screen capture, electrical power measurements, PC software.
SCOPEMETER
FLU,196 2 100 1GS/s Colour, DMM, auto screen capture
16 channel logic analyser, serial trigger, usb, i2C, SPI, LIN, CAN, HDTV with LAN,
HP,6104A 4 1,000 4GS/s
USB, GPIB, VGA interfaces
Software for Tektronix oscilloscopes.
TEK,WAVESTAR
Acquires and exports to common applications.

Tektronix TDS2014 100MHz 4 Channel Colour DSO Tektronix TDS3052B 2 Channel 500MHz DSO
TEK,TDS2014 AU TEK,TDS3052B AU
Sampling rate 1GS/s. Sensitivity 2mV~5V/div. Bandwidth limited to 20MHz Sampling rate 5GS/s. Memory length 10k. Sensitivity 1mV~10v/div. Time
when set to <5 mV/div. Automatic waveform measurements include period, base 1ns~10s/div. Trigger functions include video. Automatic waveform
frequency, + width, - width, rise time, fall time, max, min, peak to peak, mean measurements. FFT Analysis. Wave alert & e-scope web based control.
and RMS. Includes FFT Analysis as standard, TDS2CMA GPIB & RS232 Colour LCD with digital phosphor function. Centronics, GPIB (IEEE-488),
interfaces. Ethernet, and RS232 interfaces. In-built FDD.
Tektronix TPS2014 100MHz 4 Channel Powerscope Tektronix TDS3054 500MHz 4 Channel DSO
TEK,TPS2014 AU TEK,TDS3054 AU/NZ
Sampling rate 1GS/s. All 4 channels isolated for floating measurements. Sampling rate 5GS/s. Memory length 10k. Sensitivity 1mV~10V/div. Time
Sensitivity 2mV~5V/div. Bandwidth limited to 20MHz when set to <5mV/div. base 1ns~10s/div. Trigger functions include logic, advanced video, pulse
Measurements for current and voltage distortion and their spectral content, width & glitch, plus slew rate. Automatic waveform measurements. Colour
harmonics, instantaneous power, power factor and switching loss. Automatic LCD with digital phosphor function. FFT, integration and differential functions.
waveform measurements include period, frequency, +width, -width, rise time, Centronics, GPIB (IEEE-488) & RS232 interfaces. TDS3FFT (FFT analysis
fall time, max, min, peak to peak, mean & RMS. Includes FFT Analysis as module) & TDS3TRG (advanced trigger module) included. In-built FDD.
standard. Power analysis package, low & high voltage power probes (P5120
probes: dc to 200MHz, 1,000Vrms etc). Battery operation.
> NEW
Tektronix DPO4054 4 Channel Memory scope
TEK,DPO4054 AU
Wave Inspector® controls, delivers the performance you need to visualize
even your most demanding signals. 10 Megasample record length on all
channels.

Tektronix TDS2024 4 Channel 200MHz Colour DSO


TEK,TDS2024 AU
Sampling rate 2GS/s. Sensitivity 2mV~5V/div. Bandwidth limited to 20MHz
when set to <5 mV/div. Automatic waveform measurements include period,
frequency, +width, -width, rise time, fall time, max, min, peak to peak, mean
and RMS. Includes FFT Analysis as standard, TDS2CMA GPIB & RS232
interfaces.


general electronic test equipment
Digital Storage Oscilloscopes
Tektronix TDS3054B 500MHz 4 Channel DSO Fluke 199C Scopemeter 200MHz Hand-held
TEK,TDS3054B AU/NZ FLU,199C-SCOPEMETER AU
Sampling rate 5GS/s. Memory length 10 k. Sensitivity 1 mV - 10 v/div. Time FLU,199 NZ
base 1ns~10s/div. Trigger functions include video. Extensive automatic Colour digital oscilloscope, 200MHz bandwidth, 2 channel with DMM
waveform measurements. Including FFT, TV trigger, advanced analysis feature. Colour display 14.4cm with persistence feature. Real time sampling
(TDS3AAM), and limit testing (TDS3LIM). Colour LCD with digital phosphor 2.5GS/s. Input sensitivity 5mV/div~100V/div. Glitch capture 3ns using pulse
function. VGA, GPIB (IEEE-488) & RS232 interfaces included (TDS3GV). width triggering. Timebase range in scope mode 5ns/div~2min/div. Trigger
In-built FDD. Comes with TDS3BATB for battery operation. types auto, free run, single shot, edge, delay, video, video line, selectable
pulse width & external. Automatic capture and replay of last 100 screens.
Measures electrical power properties such as VA, VAR, etc. Inputs are
isolated (1kV CAT II/600V CAT III). PC software. Battery operation 4h.

Tektronix THS730A 200 MHz Battery DSO


TEK,THS730A AU
Dual channel battery portable digital storage oscilloscope with digital
multimetre facilities. Max sampling rate 1GS/s. Suited to high voltage
applications depending on probe selection. Max input 640V rms, max float
HP/Agilent MSO6104A 1GHz Digital Oscilloscope with Logic
HP,6104A AU
600Vrms. Waveform processing including watts calculations. Video trigger.
Agilent 6104A 1 GHz 4 + 16 channel mixed signal oscilloscope (MSO).
RS232 interface. Use TEK,WAVESTAR software for PC interface.
4Gsa/s. XGA Colour display updates 100,000 waveforms/sec with 256 levels
Tektronix Wavestar Software for TDS DSO intensity. 4 analogue channels and 16 logic channels. Deep memory. 8 digit
TEK,WAVESTAR AU frequency counter function. Triggering includes video, HDTV, I2C, SPI, LIN,
Acquires, prints, and exports waveforms and screen images as graphics CAN, and USB. FFT analysis included. LAN, USB, GPIB, & XGA interfaces
images or data values. Exports to common packages, eg. MS Word, Excel. standard.
Obtains data via RS232, GPIB and FDD.
Yokogawa DL1540L 150MHz 4 Channel DSO
YEW,DL1540L AU/MY
In-built printer & FDD. Amplifier bandwidth 150MHz. Sampling rate 200MS/
s. Sample memory of 2Mword for 2 channels & 1Mword for 4 channels.
BMP, TIF HPGL, postscript & comma separated waveform formats. GO/
NOGO testing of waveforms. External sample rate input - useful for rotating
machinery work. Waveform computations including FFT. Averaging function
to reduce the S/N ratio, accumulate function. GPIB interface.
Fluke 196 100MHz 2 Channel Portable Scopemeter
FLU,196 NZ
Real-time sampling 1GS/s per input. Connect & view automatic triggering,
a full range of manual trigger modes plus external triggering. 27,500 points
per input record length using Scoperecord™ mode. Automatic capture and
replay of 100 screens. Automatic waveform measurements 24. Cursors,
zoom and real-time clock. 1kV independently floating isolated inputs.
Includes a 5000 count true-rms multimeter and a Trendplot™ paperless
recorder.

Non-Storage Oscilloscopes
Tektronix 2205GM 40MHz Dual Trace Oscilloscope Tektronix 300MHz Portable Oscilloscope 4 Channel
TEK,2205GM AU TEK,2465 AU
Vertical sensitivity 5mV/div~5V/div. Timebase 0.1µs~0.5sec/div x10 2mV~5V/div. Dual timebase with delayed sweep, 500ps~0.5s/div. 50Ω &
magnifier. TV line and field trigger. 1mΩ input impedance.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 
general electronic test equipment
Probes and Accessories
Model Type Bandwidth Attenuation Voltage Max Current Max (A)
FLU,80K-40 DC~100MHz 1:1,000 40kV dc, 28kV ac
MET,HT212-30KDC DC 1:100 30kV dc
TEK,P6015 Voltage high 75MHz 1:1,000 40kV
COL,HV40B dc to 300Hz 1,000:1
ACR,SI9000 Voltage isolation 15MHz 1:20, 1:200 700V
BEL,CG-100A Current clamp-on AC DC dc~1kHz 660 rms 100
TEK,P6302-CT5 Current clamp-on 20 MHz 50K
TEK,P6158 Passive probe 30GHz 1:20
TEK,5200 Differential probe dc to 25MHz 1300V
See also Electrical Transducers

Agilent 82357A GPIB/HPIB/IEEE488 to USB interface National Instruments GPIB-USB Interface with Plotter Software
HP,82357A AU NAT,GPIB-USB-HS AU
Allows all GPIB/HPIB/IEEE488 equipment to controlled from any USB High speed GPIB to USB interface. Provides control of GPIB/HPIB/IEEE488
equipped PC (not MACs). Drivers for PC. Separate software may be devices from a USB equipped PC (requires Win 2000 or later operating
required for equipment being controlled. system). Includes software to allow PC to emulate a GPIB plotter. Plotter
software outputs plots as HPGL, HPGL/2, JPEG, TIFF, BMP & WMF. Plotter
Fluke 80K-40 High Voltage Probe software can emulate HP 7440, HP 7470, HP 7475, HP 7550 & HP 7570
FLU,80K-40 AU
pen-plotters.
1~40kV dc or peak ac, 28kV ac rms. Input resistance 1GΩ, division ratio
1,000:1. Note: input impedance of DVM must be 10MΩ or reading will be Tektronix P5200 Isolated Differential Probe
wrong. TEK,P5200 NZ
High voltage differential probe to provide a safe means of measuring circuits
with floating potentials up to 1kV from earth to ground and up to 1,300V
differential. Range settings are 1/50 & 1/500. Bandwidth: dc to 25MHz
accuracy is ±3%, input impedance is 8MΩ, 3.5 pF between inputs. Rise
time is 14ns.
Tektronix P6158 Passive RF Probe dc 3GHz 20X
TEK,P6158 AU
Attenuation dc~3GHz 20X. Input resistance 1kΩ.
Tektronix P6015 40kV High Voltage Probe
TEK,P6015 AU
Acree SI9000 Differential Probe Bandwidth 75MHz. Input rating: 40kV pulse, 20kVdc plus peak ac. Derating
ACR,SI9000 AU
with frequency applies. Input impedance 100MΩ. Attenuation x 1000.
Input probe for converting oscilloscopes, etc, to floating input for power
measurements, etc. Input attenuation 1/20 & 1/200 with 2MΩ impedance to USB to RS232 Converter
earth. Bandwidth dc~15MHz. Max input 700Vac. Input range up to 700Vdc USB,232CONVERTER AU
in 1/200 mode. Battery operated. Stackable expansion module that connects to a PC or server via the USB
port. Provides 1 high speed RS-232 serial port. System Requirements;
Bell CG-100 A Clip-on Current Gun pentium class, USB type A, Win 98, ME, 2000, XP, MAC 8.6 & later.
BEL,CG-100A AU
Current range dc, ac 10A~100A. DC~1kHz, accuracy 2%, 100% overrange
capacity, clamp ¾“Ø, 30h battery operation, IV output for oscilloscope.


general electronic test equipment
Multimeters and Electrometers
Model Type Application Scale (digit) Interface True RMS Max (V)
FLU,177
FLU,189

HIO,3256-50 Digital HiTester multimeter General 6 No 1,000


Multi Function Digital
HIO,3805
Multimeter
MET,MX44

MET,MX53
General
MET,MX54 4½ 1,000
Multimeter
MET,MX51EX Intrinsically safe

FLU,87 Yes
FLU,87-2

HP,3400A RMS voltmeter Audio/RF Analogue Analogue output 300


FLU,8010A 3½
LEM,UNIGOR355 4¾
General IR interface Yes
LEM,UNIGOR380 Multimeter 6 1,000
HP,34401A RS232/HPIB

HP,3455A-NATA Precision HPIB Yes
Powermeter - TRMS
GOS,METRAHIT-29S Precision ±310,000 count IR interface Yes CAT III 600
Multimeter
SIM,SS2X Charge measurement Electrostatic Analogue 200 kV/m

MMM,709 Electrostatic meter Static voltage 4 No 8,000

>NEW
Fluke 87-2 Digital Insulation Multimeter
FLU,87-2 MY
>NEW
Fluke MultiMeter with Backlight
FLU,177 AU
A combined digital insulation tester with a full-featured, true RMS digital General purpose multimeter. True RMS voltage and current measurements,
multimeter in a single, compact, handheld unit, which provides maximum digital display with analog bargraph and backlight, manual and automatic
versatility for both troubleshooting and preventative maintenance. ranging, display Hold and Auto Hold, frequency and capacitance
measurements. Overvoltage category EN61010-1 CAT III 1000V/CAT IV
600V.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 
general electronic test equipment
Multimeters and Electrometers

>NEW
Fluke Logging Multimeter
FLU,189 AU
Metrix MX54 Digital Multimeter
MET,MX54 AU
Measures ac/dc voltage and current, resistance, frequency, and capacitance.
Higher end multimeter. PC interface for data exchange, internal memory 4½ digit display giving a sensitivity of 10µV & 10nA. Ranges: voltage
allows stand-alone logging of up to 1000 measurements. Extremely fast 500mV~1,000V (750V ac), current 500µA~10A, resistance 500Ω~50MΩ
readings true RMS AC + DC measurements, 100kHz ac bandwidth for with a max resolution of 10mΩ, frequency; 0.6Hz ~500kHz; dB measurement
voltage and current, dual display with bargraph and two-level backlight, min/ over impedance range 1~9,999Ω.
max/average with real time clock and 250µs Fast Min-Max, Temperature
measurement -200ºC~1350ºC, dBV/dBm with selectable reference.
Metrix MX55 TRMS Multimeter
MET,MX55 MY
Overvoltage category EN 61010-1 (IEC 1010-1) CAT III 1000V/CAT IV
True rms digital multimeter measuring ac/dc voltage & current, resistance,
600V.
frequency. 4.5 digit display.
Metrix MX51EX Intrinsically Safe Digital Multimeter
MET,MX51EX AU
Resolution 5,000 count with 0.1% basic accuracy. Measures ac/dc voltage
and current, and resistance. Voltage sensitivity 100µV. Max voltage 1kV dc,
750Vac. Max current 10A. Intrinsic safety limits of 60V & 500mA.
Metrix MX53 Hand Held Digital Multimeter
MET,MX53 AU
Display 50,000 count with 34 segment bar graph. Vdc range 500mV~1kV.
Vac range 500mV~750V. Current range 500µA~10A. Resistance
range 500Ω~50MΩ. Capacitance range 50nF, 50mF. Frequency range
0.6Hz~500kHz. Min & max value mode. Continuity and diode checking
functions.

>NEW
Hioki 3805 Multi Function Handy Type Digital Multimeter
HIO,3805 AU
HP 3400A ac True rms 10MHz Analogue Voltmeter
HP,3400A
Analogue display 10Hz~10MHz, 1mV~300V FS. Recorder output.
AU

9999 count display full scale for voltage range. Optional RS232C package
Fluke 87 Digital Multimeter
for transferring data to a PC, True rms rectified, easy harmonic distortion
FLU,87 NZ
check function, simultaneous 2-point temperature measurement, maximum,
Handheld digital multimeter. Measures ac/dc voltage, current and resistance.
minimum, average value display, 4~20mA measurement value convert to
Peak hold feature.
0-100 % display, for maintaining and serving industrial meter. Meets CAT III
600V requirements and CAT II 1kV requirements. LEM Unigor 355 Hand-held Digital Multimeter/Signal Generator
LEM,UNIGOR355 AU
Measures dc, ac trms voltage & current, resistance, frequency, capacitance,
temperature & time. Display 4¾ digit. Resolution 10µV, 10nA, 10mΩ, 1pF
& 0.01Hz. Ranges voltage 300mV~1kV, current 300µA~10A, resistance
300Ω~30MΩ, frequency 300Hz~100kHz, dB -48~63, temperature ºC/ºF, Pt
100 -200~100ºC, Pt 1000 100~850ºC. Features automatic socket shutters,
IR interface, split second chronograph, automatic measurement value
storage, etc.
LEM Unigor 380 Digital Multimeter
LEM,UNIGOR380 AU
Precision 6 digit multimeter. Measures dc, ac trms voltage & current,
resistance, frequency, capacitance, temperature & time. Resolution
1µV, 1nA, 1mΩ, 1pF & 0.001Hz. Ranges voltage 300mV~1kV, current
300µA~10A, resistance 300Ω~30MΩ, frequency 300Hz~300kHz, dB -
48~63, temperature ºC/ºF K -200~1,372ºC, J -210~1200ºC. Features
Gossen Metra Hit 29S Powermeter - TRMS Multimeter automatic socket shutters, IR interface, split second chronograph, automatic
GOS,METRAHIT-29S AU
measurement value storage, etc.
High Precision Digital Multimeter
HP 34401A Digital Multimeter
HP,34401A AU
Precision 6½ digit multimeter. 100nV sensitivity on dc 120mV range. Max dc
input 1kV. Measures ac voltage, dc & ac current to 3A, 2 or 4 wire resistance
to 120MΩ, period & frequency. Max reading rate 1,000/s. Maths functions
including limits test. 512 point storage. RS232 and HPIB interfaces.
Keithley 2503 Static Detector Probe
KEI,2503 AU
Detects voltage due to charge on small surface areas. Used at a distance of
6mm from a surface having a charged plane of at least 13mmØ.
Simco SS2X Electrostatic Charge Meter (Analogue)
SIM,SS2X AU
Designed for detecting and measuring the voltage and field strength
Hioki 3256-50 Digital Multimeter CAT II 1kV & CAT III 600V associated with static charges on objects and materials. Capable of
HIO,3256-50 AU measuring voltages from 0 ~200 KV and field strength from 0~4000MV/M
Hioki 3256-50 Digital HiTester Multimeter, CAT II 1000V and CATIII 600V
3M 709 Electrostatic Meter
AC/DC, Current 10A AC/DC.
MMM,709 NZ
Digital electrostatic meter. Reads 20kV at 25mm distance, accuracy ±10%.
2 volt recorder output.


general electronic test equipment
DC Power Supplies
Model Current Max (A) Voltage (Vdc) Dual Variable
HP,E3640A 3, 1.5 8, 20 No
Yes
LAB,622 2
30
RED-30V-30A 30 No
BWD,246A 5 36 Yes
TRI,PD35-20 20 35 Yes
SOR,DCR10-120B 120 10
SOR,DCR600-3B 3 600
SOR,DCS60-50 60
AUS,AD2K5 No
50 48
INV,MPS48DC2400W
TRI,PD35-10D 10 35 Yes
XAN,XKW60-50 50 60

BWD 246A Dual Power Supply Sorensen DCR600-3B dc Power Supply


BWD,246A AU SOR,DCR600-3B AU
Dual output 0~36V, 0~5A per section. Use in series, parallel or tracking 0~600V, 0~3A.
modes.
Trio PD35-20 DC Power Supply
TRI,PD35-20 AU
Output 0~35V, 0~20A. Constant current, constant voltage. Multiple parallel
or series operation. Remote programming of voltage or current by external
voltage or resistance.
Ausmode AD2K5 48V 50A Rectifier
AUS,AD2K5 AU
DC rectifier (power supply), 50A @ 48V. Voltage not adjustable. Use to
power telecoms and other battery supported equipment.
Agilent E3640A Programmable DC Power Supply
HP,E3640A AU
30W single-output programmable power supply with built-in GPIB and RS232
connectivity and SCPI language compatibility. 0~8V/3A or 0~20V/1.5A. Sorensen DCS60-50, 60V 50A dc Power Supply
Over-voltage protection and remote sensing. Low noise and excellent SOR,DCS60-50 AU
regulation. Front and rear output terminals. 0~60V, 0~50A. Max power on a 240V 3ph supply 3kW, 2.5kW on a 1ph
240V supply. On 1ph 50V @ 50A or 60V @ 42A. Remote programming.
Trio Kenwood PD35-10D 35V 10A Power Supply
TRI,PD35-10D AU
Output 0~35V, 0~10A. Constant current, constant voltage. Multiple parallel
or series operation. Remote programming of voltage or current by external
voltage or resistance.
Invensys Intergy Mini Power System 48V dc 2.4kW Supply
INV,MPS48DC2400W AU
Sub-rack Mini System 19” rack mount range. Ideal solution for low power
telecommunications applications (Premises Data Networks and IP Routers,
Lab 622 Dual 0~30Vdc DC Power Supply Local Loop Transmission Systems and Wireless) requiring compact, efficient
LAB,622 NZ
and flexible dc power supplies. Includes an integral dc distribution panel
Adjustable current limit of 0~2A dc. and an SM30 Series Intergy Supervisory Module. All system settings are
fully adjustable in software. Input: R1148: 220/240Vac, 50/60Hz (nominal).
Redfern 30V / 30A Power Supply Power factor: >0.98 @ 30~100% max system current. Efficiency: >89%.
RED,30V-30A NZ Output; voltage 48V, 45~60Vdc, current @ 48Vdc 50A (2400W). Dimensions:
Adjustable current trip from 0~30V. Voltage and current meters. 133H x 275W mm overall. Weight: 12kg typical configuration.
Sorensen DCR10-120B dc Power Supply Xantrek XKW60-50 60V 50A dc Power Supply
SOR,DCR10-120B AU/MY XAN,XKW60-50 AU
0~10V, 0~120A. 0~60V, 0~50A. Constant current and constant voltage. Analogue
programming. Operation of multiple units in series or parallel.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 
general electronic test equipment
Function Generators
Model Special features Frequency Max (MHz) Frequency Min (µHz) Voltage Max Arbitary
HP,3325B High stability & accuracy 21 MHz 1

HP,33120A 15 MHz 100


10Vp-p Yes
HP,33220A 20MHz
1
HP,33250A 80 MHz

> NEW
Tektronix 3022/25MHz Arbitrary Function Generator
TEK,AFG3022 AU
HP 33120A Function/Arbitrary Generator
HP,33120A AU/MY
Frequency range 15MHz sine & square waveforms, and 100kHz triangle &
Dual channel function/arbitrary waveform generator. Frequency range ramp waveforms. Gaussian noise to 10MHz. Output into 50, 50mV~10V pp.
1mHz ~25MHz sine, 12.5MHz square & pulse waveforms, 250 kHz triangle, AM, FM, FSK, and burst modulation. Optional Benchlink software allows
ramp, noise & DC waveforms. Arbitrary waveform generation 12.5MHz. waveforms to be captured and played back. HPIB & RS232C interfaces.
Gaussian noise to 25MHz. Output into 50Ω 10mV~10V P-P. AM, FM, FSK, Some assets include option 001 phase lock and high stability TCXO timebase
and burst modulation. HPIB, USB, & LAN interfaces used with included - input & output 10MHz with phase offset.
software allows waveforms to be created on PC and imported into unit. Full
screen display also allows display and editing of waveforms on unit itself.

HP 33250B Synthesized Function Generator

> NEW
Tektronix 3102/100MHz Arbitrary Function Generator
TEK,AFG3102 AU
HP,3325B
Sine frequency range 1µHz~21MHz, square wave/triangle/ramps to 11MHz.
Sweep generator function. In-built modulation generator which includes
AU

Dual channel function/arbitrary waveform generator. Frequency range arbitrary waveforms with arbitrary, sine, and square wave outputs. Output
1mHz~100MHz sine, 12.5MHz square and pulse waveforms, and 250kHz phase can varied with 0.1O resolution and multiple units can be locked
triangle, ramp, noise, and DC waveforms. 12.5MHz Arbitrary waveform together for variable phase output signals. Very high amplitude resolution
generation. Gaussian noise to 25MHz. Output into 50ohms 10mV~10V P-P. and setting accuracy.
AM, FM, FSK, and burst modulation. HPIB, USB, and LAN interfaces used
HP/Agilent 33250A 80MHz Function/Arbitrary Waveform
with included software allows waveforms to be created on PC and imported
Generator
into unit. Full screen display also allows display and editing of waveforms
HP,33250A AU
on unit itself.
Frequency range 80MHz sine & square waveforms. 50MHz pulse waveforms
with variable rise/fall times. 25MHz arbitrary waveforms, 1MHz triangle &
ramp waveforms. White noise to 50MHz. Output into 50Ω 10mVpp~10Vpp.
AM, FM, FSK, and burst modulation. Intuilink software for programming
arbitrary waveforms. HPIB & RS232C interfaces.

Agilent 33220A 20MHz Function/Arbitrary Generator


HP,33220A AU
Function/arbitrary waveform generator. Frequency range 20MHz sine &
square waveforms, 200kHz pulse, triangle, ramp, noise, and DC waveforms.
Gaussian noise to 10MHz. Output into 50Ω 10mV~10V P-P. AM, FM, FSK,
and burst modulation. Includes option 001 external timebase reference.
With optional Benchlink software waveforms can be captured and played
back. HPIB, USB, & LAN interfaces.


general electronic test equipment
Pulse Generators
HP 8012B Pulse Generator
HP,8012B AU
Pulse generator 1Hz~50MHz. Variable transition times down to 5ns. Amplitude +10V with selectable source impedance. Pulse width 10ns~1s. External
trigger and gate.

LCR Meters
Stanford Research SR1720 LCR Bridge Tegam 3550 45Hz-5MHz Programmable LCR Meter
SR,SR720 AU TEG,3550 AU
Automatic LCR bridge with 0.05% accuracy. Ranges: inductance Programmable Impedance/LCR Meter. User selectable test frequency from
0.0001µH~99,999H; capacitance 0.0001pF~99,999µF; resistance 42.0Hz~5.00MHz. 18mS measurement speed. 0.10% basic accuracy. Fully
0.0001Ω~2,000MΩ. Also measures Q & D. Test frequencies 100/120Hz, programmable with18 measurable parameters and absolute or percentage
1/10/100kHz. Indicates value, deviation, % deviation, or bin number. DC comparator. Binning function supports 10 output bins. Output to 3 highly
bias internal 0~2V, external 0~40V. Complete with optional Kelvin leads. visible LED displays. Standard RS232C & I/O interfaces

Electrical Calibrators
Model Type Description Accuracy %
DAN,DR60 Resistance box Decade resistance box
GR,1433-20 Resistance Box Decade resistance box
GR,1433B-NATA Resistance box 1~11.1MΩ Decade resistance box. 6 decades x 1Ω
0.01
GR,1433F-NATA Resistance box 0.01Ω~11kΩ Decade resistance box. 7 decades x 0.01Ω
YEW,2553 DC voltage & current standard 0.02
YEW,2554 Portable DC voltage & current standard 0.05

> NEW
Genrad 1433-20 Decade Resistor
GR,1433-20 MY
Genrad 1433B 1.1 m 6 Decade Resistance Box - NATA
GR,1433B-NATA
Six decades by 1Ω~1.1MΩ, accuracy 0.01%. NATA calibrated.
AU

Resistance range from 1mΩ~111MΩ. High accuracy 0.01% up to


Genrad 1433F 111 K 7 Decade Resistance Box - NATA
10MΩ steps. Low temperature coefficient, 5 ppm/°C. Good frequency
GR,1433F-NATA AU
characteristics, excellent stability (10ppm/yr, 25ppm/3yrs), low zero
Seven decades by 0.01Ω~111KΩ, accuracy 0.01% +0.002Ω. Useful for
resistance (<1 mO per decade). May be used for RTD simulation. Rack
platinum resistance thermometer calibration. NATA calibrated.
mount option.
Danbridge DR60 Decade Resistor Resistance
DAN,DR60 MY
Decade Resistor. Maximum 10kΩ. Smallest resolution 0.01Ω.
Yokogawa 2553 dc Voltage/Current Standard
YEW,2553 AU/MY
1µV~12V, 0.1µA~120mA, accuracy ±0.02%, power 240V/50Hz.
Yokogawa 2554 Portable dc Voltage/Current Standard
YEW,2554 AU
Genrad 1432T Decade resistance box 10mV, 100mV, 1V, 10V, 100V, 1mA, 10mA, 100mA, ±0.05% accuracy.
GR,1432T AU Internal battery or mains operation.
Ten steps of the following: 0.01Ω, 0.1Ω, 1Ω, 10Ω, 100Ω. Maximum
resistance 1KΩ.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 
general electronic test equipment
Logic/Analysers/Testers

> NEW
Protek 3290 RF Analyser/Signal Meter 2.9GHz
PRO,3290 AU
> NEW
Agilent/HP 1652B 80 Channel Logic Analyser
HP,1652B AU
RF signal analyser and level meter. Provides spectrum display up to 2.9 80 channels, maximum conventional timing rate 100 MHz, transitional
GHz, audio output, level measurement, and frequency measurement. Inbuilt timing rate 100MHz & glitch timing rate 50MHz. Memory depth/channel-
antenna. Frequency range 100 kHz to 2.9GHz with frequency steps from normal 1KB. Channel to channel delay 4ns. Minimum recognizable glitch
5 kHz. Modulation types narrow and wide band FM, AM, and SSB. Level width 5ns. Setup/hold time 10ns. 2 scope channels. Bandwidth 100MHz.
measurement minimum frequency - narrow band FM 1 MHz, wide band FM, Simultaneous maximum sampling rate/Ch - 400 MSa/s. HPIB,RS232C.
AM, SSB 10 MHz. Bandwidth - narrow band FM 12.5 kHz, wide band FM FDD.
180 kHz, AM & SSB 2.4 kHz. Input impedance 50 ohms.

Agilent 16500C Logic Analyser


HP 1662A 68 Channel Logic Analyser HP,16500C AU
HP,1662A AU/MY
Mainframe with 16555D acquisition card and 16522A pattern generator
Timing analysis 250MHz all channels, 500MHz half channels. Transitional:
module. 110MHz 68 channels. Memory depth 2M (4M in half channel
125MHz all channels, 250MHz half channels. Glitch: 125MHz half channels.
timing mode). Minimum detectable glitch 3.5ns. Advanced trigger macros
State analysis to 100MHz on all channels. Memory 4k/channel, 8k/channel
for capturing elusive problems.
in half-channel modes. 4 clock channels available. HPIB & RS232C ports.
In-built DOS format FDD used to load inverse assemblers and transfer
measurement data to a computer. Compatible with most HP preprocessors
and inverse assemblers.

PROM Programmers
IceTech LV48 Programmer Hi-Lo All 11 Programmer
ICE,LV48 AU ALL,11 AU
Eprom programmer for single device with laptop and preloaded software. Programmer for byte wide EPROM, EEPROM and flash PROM with 24~32
Programs devices up to 48 pins. pins. Enables programming or copying of up to 8 devices at a time. Adaptors
provided to convert standard dip arrangement to PLCC for programming/
Data IO Chipwriter Standard copying of single (one only) PLCC packages. Unit will handle devices up to
DAT,CHIPWRITER AU
8Mb. i.e. 27C010~27C080.
Eprom programmer for single device with laptop and preloaded software.
Programs devices up to 40 pins. Spectronics Ultra Violet PROM Eraser
SPE,ERASER2 AU
Data IO Chipwriter Gang 8 Chip Holds up to 8 devices. 0~60min timer, 240V/50Hz operation.
DAT,CHIP-GANG AU
Eprom programmer for 8 devices. Eight copy sockets and one master socket.
Can be used with a PC or in stand alone mode (two button operation).
Programs devices up to 32 pin DIP.

Frequency Response Analysers


HP35660A 100kHz Dual Channel Spectrum Analyser
HP,35660A AU/MY
Displays frequency response, power spectrum, linear spectrum, coherence,
> NEW
HP35670A 100kHz Spectrum Analyser
HP,35670A AU
cross spectrum, power spectral density, and time. 401 line resolution. Signal Quad channel 100 khz spectrum analyser. Up to 1600 line resolution.
sources: fixed sine, random noise, chirp. Built-in disk drive. HPIB interface. Displays frequency response, power spectrum, linear spectrum, coherence,
Bandwidth is 102.4kHz for single channel measurements and 51.2kHz for cross spectrum, power spectral density, and time. Signal sources: Fixed &
dual channel measurements. Swept sine, Arbitrary Waveform, Random noise, Chirp. Built-in disk drive.
HPIB plotter interface. Bandwidth is 102.4, 51.2 and 25.6KHz for single,
dual and quad channel measurements respectively.

10
Performance on-the-move

Strength in the palm of your hand Say hello to the next generation of Agilent Technologies;
the new handheld digital multimeters and oscilloscopes

New U1250A series handheld DMMs place


that are built to test and designed to save.
versatility at your fingertips!
Featuring built-in battery charging capability, exciting
• 50,000 count resolution, dual displays
and innovative new features and over-mould casing for
• Unlimited data logging from DMM to PC protection in the toughest conditions.
• Programmable square wave generator
If you need a test instrument that offers the ultimate
• Temperature, Capacitance, Maths functions
portable test capabilities, Agilent’s range of handheld
• 20MHz frequency counter
digital multimeters and oscilloscopes are the right choice.

New U1600A series handheld scopes bring high Redefining Feature-Rich Portability with
performance on the move!
the New Handheld Series
• Scope-DMM-Recorder - all-in-one
• 4.5-inch LCD colour display
View an online demo:
• FFT, Zoom and Math functions www.agilent.com/find/U1250A_showcase
• 200MSa/s sampling rate www.agilent.com/find/U1600A_showcase
• 125kB/ch memory depth

Australia 1300 726 550


(Measurement Innovation - Australia wide)
New Zealand 0800 738 378
www.agilent.com/find/U1250A
www.agilent.com/find/U1600A
general electronic test equipment
Frequency Counters
Model Type Frequency (GHz)
RAC,9906 Universal frequency counter dc~0.200

SIC,WL260-PC230 Optical timing sensor

PHI,PM6666 dc~1
HP,5350A Universal frequency counter
HP,53181A dc~3

HP,5352B Automatic microwave counter 10Hz~20GHz


HP,5385A Universal frequency counter, DC operation dc~1GHz

ADV,TR5212 Universal frequency counter 10MHz~18GHz

Racal 9906 Frequency Counter/Timer HP 53181A 3GHz Frequency Counter


RAC,9906 AU HP,53181A AU/MY
Counter/timer 200MHz. Eight digit display. Measures frequency, period, Option 010 high stability timebase included. HPIB interface. PC based
totalise, time interval and ratio. Input impedance 1MΩ. Input sensitivity Benchlink meter software available.
10mV.
HP 5350A 20GHz Frequency Counter
Sick WL260-P230 Reflex Photoelectric Switch HP,5350A MY
SIC,WL260-P230 AU Automatic Microwave Counter. Input 1: 500MHz~20.0GHz 50Ω input
Light and sensor in the same unit. Detects reflection from reflector mounted impedance. Input 2 10Hz~525MHz at 50Ω. 10Hz~80MHz at 1 MΩ. HPIB
on or behind the object to be detected. Range 0.01~5m. Output compatible interface standard. Option 006 input damage protection included.
with Racal 9906 counter. Mains operated. Supplied 50 x 50mm reflector.
Does not work with normal mirror, white card etc, detects interruptions using HP 5352B 40GHz Frequency Counter
supplied mirror. HP,5352B AU
Automatic microwave counter. Input 1 500MHz~40GHz. Input 2
Philips PM6666 1.1GHz Universal Counter 10Hz~525MHz. Sensitivity at 40GHz to 20dBm. TCXO timebase with aging
PHI,PM6666 AU rate 1 part in 10 million per month. HPIB interface. Input connector APC-3.5
Frequency, period, time interval, totalise, and ratio measurements. GPIB (male) with collar; type N adaptor included.
interface. High stability MTCXO timebase option fitted.
HP 5385A 1GHz Frequency Counter
HP,5385A AU
Eleven digit display. Also measures period up to 0.1s. TCXO timebase.
Operates from ac or 9~15Vdc. HPIB interface.

12
RF & MICROWAVE
RF Signal Generators
Model Type (All programmable) Frequency Output
HP,ESG-3000A AM/FM microwave signal generator 250kHz~3GHz
HP,ESG-D4000A AM/FM high stability microwave signal generator 250kHz~4GHz
HP,8648B High stability signal generator 9kHz~2GHz 13dBm~-136dBm
HP,8648C 9kHz~3.2GHz
AM/FM high stability signal generator 10dBm~-136dBm
HP,8648D 9kHz~4GHz
FLU,6060B AM/FM high stability signal generator 10kHz~1,050MHz -127dBm~13dBm

HP E4432B ESG-D3000A 3GHz RF Digital Signal Generator HP 8648C-1E5 3GHz Signal Generator
HP,ESG-D3000A MY HP,8648C AU/MY
RF signal generator with digital modulation facilities. Frequency range Signal generator 9kHz~3.2GHz with AM/FM/Phase modulation output range
250kHz~3GHz, resolution 0.01Hz. AM, FM, phase, & pulse modulation. from +10~-136 dBm with ±1 accuracy up to 2.5GHz. 0.001Hz resolution.
Wideband AM modulation. DC to 10MHz. Internal modulation and pulse Complete with option 1E5 high stability timebase (<±0.1ppm/yr).
generator to 50kHz. Step sweep of frequency and power. Included option
UN3 provides DECT, GSM, NADC, PDC, PHS, & TETRA standards. External
HP/Agilent 8648D-1E5 4GHz Signal Generator
HP,8648D AU/NZ/MY
analogue I & Q modulation inputs. Option 1E5 high stability reference
Signal generator 9kHz~4GHz with AM/FM/Phase modulation output range
0.1ppm/yr included.
from 10~-136dBm with ±1dB accuracy up to 2.5GHz. 0.001Hz resolution.
Complete with option 1E5 high stability timebase (<±0.1ppm/yr).

HP E4433B ESG-D4000A 4GHz RF Digital Signal Generator


HP,ESG-D4000A AU
Signal generator with digital modulation facilities. Frequency range Fluke 6060B 1GHz Signal Generator
250kHz~4GHz, resolution 0.01Hz. AM, FM, phase, & pulse modulation. FLU,6060B AU
Wideband AM modulation. DC to 10MHz. Internal modulation and pulse Programmable high stability AM/FM signal generator. 0.01~1.05GHz, 10Hz
generator to 50kHz. Step sweep of frequency and power. Option 1E5 high resolution, 13~-127dBm output. Digital display of frequency, modulation and
stability reference 0.1ppm/yr included. amplitude. Fifty complete front-panel settings can be stored in non-volatile
HP 8648B 2GHz Signal Generator (Analogue) memory for frequently repeated tests. Reverse power protection. Optional
HP,8648B AU/MY
low rate ac FM and IEEE-488 interface fitted.
Frequency range 9kHz~2GMHz. Output range 13dBm~-136dBm, 1dB
accuracy over entire frequency range, resolution 0.001Hz. Full remote
control via GPIB (IEEE488) interface.

RF Sweep Generators
HP 8350B Sweeper Mainframe HP 83592A Sweeper Plug-in 10Mhz~20GHz
HP,8350B AU/MY HP,83592A AU
Operates directly with HP,8757A scalar network analyser and HP,7475A Broadband plug-in for HP,8350B mainframe. Frequency range
plotter or HP,2225A printer. 10MHz~20GHz. Max levelled output power 10dBm. External AM and FM
modulation.
HP 83525B 10MHz~8.4GHz Sweep Module
HP,83525B AU HP 83592C High Power 13dB Sweeper Plug-in
Sweep generator module for HP,8350B. Frequency range 10MHz~8.4GHz. HP,83592C AU
Broadband plug-in for HP,8350B mainframe. Frequency range
HP 83594A Module for 8350B 2 to 26.5GHz 10MHz~20GHz. Max levelled output power 13dBm. External AM and FM
HP,83594A AU
modulation.
Broadband sweeper plug-in for HP,8350B mainframe. Frequency range
2~26.5GHz. Max levelled output 10mW up to 20GHz, 2.5mW up to
26.5GHz.

RF Amplifiers
ENI 604L 4 W Wideband 1GHz RF Amplifier
ENI,604L AU
Linear wideband RF power amplifier. 4W output at an input of 0.13mW from 0.5~1GHz. Saturated output 7W 0dBm input. Extended performance gives
saturated output to a max of 16W at 10MHz and 12W at 100MHz typically.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 13
RF & MICROWAVE
Spectrum Analysers - High Frequency
Model Type Frequency Resolution (Hz)
HP,8591E 9MHz~1.8GHz
Spectrum analyser
HP,8594E 1kHz
9kHz~2.9GHz
HP,8594E-G Spectrum analyser with tracking generator
ADV,R3365A Spectrum analyser with tracking generator 100kHz~8GHz 10
HP,E4407B 9kHz~26.5GHz 30
HP,8591 Spectrum analyser 9kHz~1.8GHz 1kHz
HP,8593E 9kHz~22GHz 30
HP,8563E Spectrum analyser, high resolution 9kHz~26.5GHz 1
2.5~2.5GHz
AIR,AIRMAG SPEC AN Spectrum analyser
4.9~5.9GHz
ANR,MS2711A Portable spectrum analyser 10kHz
9kHz~3GHz
ANR,MS2711D Spectrum analyser, colour, portable
100
ANR,MS2711D-6-29 Spectrum analyser with power meter 9kHz~6GHz
ANR,S332B 10
Network analyser with spectrum analyser 9kHz~3GHz
ANR,S332D 100
ANR,S332D-29 Network analyser with spectrum analyser with colour screen 10
RS,FSH3-TG Spectrum analyser with tracking generator and return loss bridge 100kHz~3GHz
RS,FSH3-TG-V Spectrum analyser with tracking generator and vector measurements 100kHz~3GHz 1kHz
RS,FSH6-TG 100kHz~6GHz
Portable spectrum analyser
ADV,U3771 9kHz~31.8GHz 100

Gear up for your next adventure


The R&S®FSH - for on-site RF measurements
Where is your next adventure in RF measurements taking you? To install a base station on the African savanna?
To perform distance-to-fault measurements on the International Space Station? Then you need a flexible and robust
do-it-all solution - the R&S®FSH Handheld Spectrum Analyser. It’s an entire test lab that fits in one hand: spectrum
analyser, vector network analyser, high-precision power meter, test receiver, EMI/EMCE analyser and much more.
It also features a wide selection of accessories.
www.rohde-schwarz.com.au
sales@rohde-schwarz.com

14
RF & MICROWAVE
Spectrum Analysers - High Frequency
Rohde & Schwarz FSH3 Spectrum Analyser/Tracking Generator
RS,FSH3-TG
Handheld portable battery operated spectrum analyzer 100kHz~3GHz.
AU/NZ > NEW Rohde & Schwarz FSH3 Spectrum Analyser/
Tracking Generator /Vector Measurements
RS,FSH3-TG-V AU
Resolution bandwidth 1kHz~1MHz. Noise level to 3GHz -112dBm typical, Handheld portable battery operated spectrum analyser 100kHz~3GHz.
5-6GHz -102dBm typical. Colour liquid crystal display. Suitable for RF Resolution bandwidth 1kHz~1MHz. Less than -105dBm noise level
surveying applications. Includes tracking generator, VSWR bridge and (-114dBm typical). Colour liquid crystal display. Suitable for RF surveying
distance to fault (DTF) options making it suitable for antenna and cable applications. Includes Vector Transmission and Reflection Measurements
testing. Four hours of continuous operation on battery power. Cable for option, tracking generator, VSWR bridge and distance to fault (DTF) options
data transfer to PC. making it suitable for antenna and cable testing. 4h of continuous operation
on battery power. Comes with cable for data transfer to PC.

Rohde & Schwarz FSH6 Spectrum Analyser/Tracking Generator


RS,FSH6-TG AU/NZ
Specification as above but capacity is 6GHz. HP 8591E 1.8GHz Spectrum Analyser
HP,8591E AU
Range 9kHz~1.8GHz. Resolution 1kHz~3MHz. Card reader allows data
storage and also downloading of a range of measurement options (not
included). Most assets include option 010 tracking generator and option
021 HPIB interface. One analyser includes; option 130 gives 30~300Hz
resolution, option 041 HPIB interface and quasi peak detector and option
103 AM/FM demodulation.

>NEW
Advantest 31.8GHz Portable Spectrum Analyser
ADV,U3771 AU
Portable 9k to 31.8GHz spectrum analyser. 3 way power Battery, 240V &
DC. RBW 100Hz-3MHz, sensitivity -117 dBm@34 GHz (typ). Includes a
wide variety of data analysis functions & zoom function. With signals applied

> NEW
Airmagnet Spectrum Analyser
AIR,AIRMAG SPEC AN AU
to both Input 1 and Input 2, two signals such as an IF signal and a carrier
can be measured. 5 min warm-up, Support for USB for printer and memory
Storage Image formats: PNG, BMP, configuration file BIN, XML. Colour
Laptop base spectrum analyser. Specifically identify sources of interference LCD. OPT.20-High-stability frequency reference crystal.
in all Wi-Fi bands 2.4~2.5GHz and 4.9~5.9GHz, and track them to their
physical source. Automatic and real time identification of Bluetooth, cordless
phones, microwaves, analog video cameras, RF jammers and more.
Immediately “see” and name each device.

Advantest R3365A 8GHz Spectrum Analyser with Tracking


Generator
ADV,R3365A AU
Frequency range 100kHz~8GHz. Sensitivity -145dBm. Resolution
10Hz. Adjacent channel leakage power measurement and digital radio
measurement functions. Gated sweep function for TDMA and video signal
analysis. In-built tracking generator 100kHz~3.6GHz. GPIB & RS232
interfaces. Memory card reader.
HP/Agilent E4407B 26.5GHz Spectrum Analyser
HP,E4407B AU
Frequency range 9kHz~26.5GHz. Resolution bandwidth down to 30Hz.
Noise level -105~-136dBm according to frequency. Centre frequency display
with a resolution of up to 10Hz. Stores up to 200 traces in internal memory
and 200 traces on disk. Some assets include GPIB/parallel interface with
benchlink software (option A4H) and narrow resolution black/white (option
1DR).

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 15
Field tested.
Field trusted.

Master every challenge the field throws your way


Field-proven, built to last, and easy to use, the Master family from Anritsu is
the most trusted family of handheld measurement tools for RF and Microwave
field testing. So whatever you need to measure, and wherever you need to test,
you can rely on one of the end-to-end, application-specific solutions in our
Master family.
Call 1800 689 685 (Australia only) or visit our US web site www.us.anritsu.com
RF & MICROWAVE
Spectrum Analysers - High Frequency
HP 8593E 22GHz Spectrum Analyser Anritsu MS2711D 6GHz Spectrum Analyser with Power Meter
HP,8593E AU/MY ANR,MS2711D-6-29 AU
Frequency range 9kHz~22GHz. Max resolution 30Hz. Noise level -102~- Portable spectrum analyser, 9kHz~6GHz with power meter. Light weight
127dBm according to frequency. Centre frequency display with a resolution battery powered spectrum analyser with LCD. Resolution bandwidth from
of up to 10Hz. Some assets include GPIB/parallel and narrow resolution 100Hz~1MHz. Has feature which can identify the type of interfering signal.
black/white options (041 & 130). Can be used in applications such as cellular telephone walk or drive tests to
determine coverage and base station positioning and also VHF/UHF signal
HP 8582A 22GHz Spectrum Analyser surveying. Has N type connector.
HP,8562A MY
RF Spectrum Analyser, 9kHz to 22GHz. resolution 100Hz to 2MHz. HPIB Anritsu MS2711D Colour Portable Spectrum Analyser
plotter interface. ANR,MS2711D AU
Colour portable spectrum analyser, 9kHz~3GHz. Light weight battery
HP 8563E Spectrum Analyser powered spectrum analyser with colour LCD. Resolution bandwidth from
HP,8563E AU/MY
100Hz~1MHz. Has feature which can identify the type of interfering signal.
Range 9kHz~26.5GHz. Resolution 1Hz~2MHz. Sensitivity up to -139dBm.
HPIB plotter and printer interface. Can be used in applications such as cellular telephone walk or drive tests to
determine coverage and base station positioning and also VHF/UHF signal
surveying. N type connector.

HP 8594E Spectrum Analyser


HP,8594E MY
Range 9kHz~2.9GHz. Average Noise Level 400kHz~5MHz equal to or
less than 122dBm & 5MHz~2.9GHz equal to or less than 127dBm for 30Hz
RBW.
HP 8594E-G Spectrum Analyser with Tracking Generator > NEW
Anritsu Frequency Converter Module FCN4760
ANR,FCN4760 AU/MY
HP,8594E-G MY
Range 9kHz~2.9GHz. Average Noise Level 400kHz~5MHz equal to or less Block down converter for the 4.7GHz~6.0GHz frequency range designed to
than 122dBm & 5MHz~2.9GHz equal to or less than 127dBm for 30Hz RBW. work with an ANR,MS2711D (with Option 6). Adds frequency range 4.7GHz
With tracking generator option installed. ~6.0GHz to the ANR,MS2711D.

Anritsu MS2711A Portable Spectrum Analyser


ANR,MS2711A MY
Portable spectrum analyser, 9kHz~3GHz. Light weight battery powered
spectrum analyser with LCD. Resolution bandwidth down to 10kHz.
Suitable for cellular telephone walk or drive tests to determine coverage and
base station positioning. Can also be used for VHF/UHF signal surveying.
N type connector.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 17
RF & MICROWAVE
Network Analysers/Antenna & Cable Test
Return
Model Type Frequency SWR RS232 dc Supply
Loss
ANR,S331B Antenna & cable test set 25MHz~3.3GHz
ANR,S331C
Antenna & cable test set 25MHz~4GHz
ANR,S331D
ANR,S332B Antenna & cable test set plus spectrum analyser 25MHz~3.3GHz
ANR,S332D Antenna & cable test set plus spectrum analyser 25MHz~4GHz Yes Yes Yes Yes
ANR,S820A Antenna & cable test set 3GHz~20GHz
ANR,S820A Microwave antenna and cable test set 25Mhz~20GHz
ANR,C752-05 Antenna & cable test set (75ohm) plus power meter 5MHz~1.2GHz
HP,8752A Vector network analyser transmission reflection test set 300kHz~3GHz
HP,8753D 30kHz~6GHz
Vector network analyser S parameter test set
HP,8753ES 30kHz~3GHz Yes Yes
HP,8757C 60GHz
Scalar network analyser
HP,8757D 10Mhz Yes Yes

Anritsu S331D Colour Sitemaster Antenna Anritsu S820A Microwave Sitemaster 3~20GHz
ANR,S331D AU/MY ANR,S820A AU
Antenna and cable test set. Battery operated with colour display. Frequency Microwave antenna and cable test set. Portable (1.14kg) single post
range 25~4000MHz. Measures return loss, SWR, cable loss, and distance analyser, providing return loss (SWR) insertion loss and distance to fault
to fault. Integral synthesized signal generator. Return loss range 0~60dB. measurements in the frequency range of 3.3GHz~20GHz. RS232 interface.
SWR range 1~65. Distance to fault range 1,197m. Insertion loss range - Smith chart and software management tools, ac/dc and automotive adaptor.
120.00~+100dB. Cable loss range (one port) 0~30dB. Type n(f) port. RS232 A comprehensive range of precision waveguide components and adaptors
interface for printer or PC. Analysis software discs included containing are available.
distance to fault and Smith chart tools. Complete with Instacal calibration
Anritsu S820D Microwave Sitemaster 25MHz~20GHz
standard, AC/DC adaptor and 12Vdc car cigarette lighter adaptor.
ANR,S820D au
Anritsu S332B Sitemaster including 3GHz Spectrum Analyser Microwave antenna and cable test set. Portable single post analyser,
ANR,S332B AU providing return loss (SWR) insertion loss and distance to fault measurements
Antenna and cable test set with spectrum analyser. Frequency range in the frequency range of 25MHz~20GHz. Unit comes standard with
25~3300MHz for cable and antenna test. 9kHz~3GHz for spectrum analysis. RS232 interface, Smith chart and software management tools, AC/DC
Measures return loss, SWR, cable loss, and distance to fault. Integral and automotive adaptor. A comprehensive range of precision waveguide
synthesized signal generator. Return loss range 0.00 to 54.00 dB. SWR components and adaptors are available.
range 1.00 to 65.00. Distance to fault rang e 1000 m. Insertion loss range
-120.00 to +100 dB. Cable loss range (one port) 0.00 to 20.00 dB. Type
Anritsu Sitemaster Waveguide Components
ANR,WAVEGUIDE-ADAP AU
n(f) port. RS232 interface for printer or PC. Spectrum analyser resolution
Calibration components and wave guide to co-ax adaptors for Anritsu S820A
bandwidth down to 10 KHz. Analysis software discs included containing
Sitemaster antenna. Set includes 1/8 and 3/8 shorts, termination, and
distance to fault and Smith chart tools. Complete with standard load and
waveguide to co-ax adaptor.
short, AC/DC adaptor and 12 V DC car cigarette lighter adaptor.
HP 8753D 6GHz Vector Network Analyser
Anritsu S332D Colour Sitemaster incl 3GHz Spectrum Analyser HP,8753D AU
ANR,S332D AU/NZ
Vector network analyser with integral S-parameter test set. Frequency range
Antenna and cable test set with spectrum analyser. Battery operated with
30kHz~6GHz with included option 006. In-built 1Hz resolution synthesized
colour display. Standard signal table allows automated setup. Frequency
signal source. Calibration kit included.
range 25~4GHz for cable and antenna test. 9kHz~3GHz for spectrum
analysis. Measures return loss, SWR, cable loss, and distance to fault. HP 8753ES 3GHz Vector Network Analyser
Integral synthesized signal generator. Return loss range 0~60dB. SWR HP,8753ES AU/MY
range 1~65. Distance to fault range 1,197m. Cable loss range 0~30dB. 3GHz Vector Network Analyser allows complete characterization of RF
Spectrum analyser resolution bandwidth 100Hz~1MHz. Interfering signal components. Includes an integrated synthesized source, test set and tuned
feature allows identification of type of interference. Type N(f) port. RS232 receiver. The built-in S-parameter test set provides a full range of magnitude
interface for printer or PC. Analysis software discs included containing and phase measurements in both the forward and reverse directions.
distance to fault and Smith chart tools. Complete with calibration components,
ac/dcadaptor and 12Vdc car cigarette lighter adaptor.

18
RF & MICROWAVE
Network Analysers/Antenna & Cable Test
HP 8757A Scalar Network Analyser HP 85032B Calibration Kit
HP,8757A AU HP,85032B AU
Scalar network analyser (Scalar denotes gain measurement only - no phase). Calibration kit for network analysers. Simplified version without adaptors.
76dB dynamic range. Frequency range to 60GHz depending on detector
used. 3 x HP11664A’s included. Analyser will act as system controller with
HP8350B sweeper. Output to HPIB plotter or HP2225 printer.
> NEW
Emerson Process Management 375 Field Communicator
EME,375 MY
HP 8757C Scalar Network Analyser Will configure, test, and diagnose your HART® and Foundation Fieldbus
HP,8757C AU devices. Able to communicate with any device, by any manufacturer.
Scalar network analyser 10 MHz~40 GHz. 76dB (+16 to -60dBm) dynamic Intrinsically safe. Easy upgrade over the Internet. Interfaces with AMS PC
range. Three detector inputs. Two display channels. Color display. Suite Software.
Complete with 3 x HP,11664A detectors.
HP 8757D Scalar Network Analyser
HP,8757D
Measures insertion loss, gain, return loss, SWR, and power from
10MHz~110GHz.

HP 11679A Detector Extension Cable


HP,11679A MY
Extension cable for use with HP,11664A detectors and HP,8757 network
analysers. Length 7m. Extends the power and detected signal cable
length.

Field Strength Meters & Antennas


Model Type Frequency
ANR,WIFI-ANTENNA WIFI antenna 2.4GHZ~5.8GHz
ANR,ANTENNA Dipole antenna 25MHz~1.7 GHz
ADV,TR1720 Loop vertical antenna system 100kHz~30 MHz
AH,SAS-200/574 18GHz~40 GHz
Double ridge guide horn antenna
AH,SAS-200/571 700MHz~18 GHz
RS,HL013 Log periodic antenna 80MHz~1300 MHz
AN,SAS-200/550 Monopole rod antenna 100kHz~60 MHz
HOL,HI-3002 Isotropic RF radiation monitor 500kHz~6 GHz
NAR,8616 Radio frequency radiator monitor 300MHz~26 GHz
SE,MONITOR 4 Alpha, Beta, Gamma and X-Ray radiation monitor
SE,MCIK Gamma X-Ray radiation monitor
HOL,HI-3004 Isotropic RF low level field strength meter 0.5MHz~6 GHz
WG,ESM-20 Personal RF field monitor 1MHz~18 GHz
NAR,8217 Field strength meter for microwave ovens 2.4GHz
ROB,TX90 Microwave oven leakage detector 2.4GHz
PRO,3201 RF signal analyser & meter 100kHz~2.06GHz
AH,ANTENNA Log periodic antenna 300MHz~12GHz
See also TV Test Equipment

Advantest TR1720 100kHz ~30MHz Antenna AH Systems SAS-200/574 18~40GHz Antenna


ADV,TR1720 AU AH,SAS-200/574 AU
Loop and vertical antenna system. Frequency range 100kHz~30MHz. Double ridge guide horn antenna 18~40GHz. Gain in excess of 15dB. Type
Suitable for use with ADV,R4131D for field strength and EMI measurements. K(f) connector compatible with 3.5mm connectors including SMA. Complete
Antenna tuner included which can be used as an input/output filter to reject with tripod.
noise below the measuring frequency.
AH SAS-200/550-2B 100Hz~60Mhz Rod Antenna
AH Systems SAS-200/571 Antenna AH,SAS-200/550 AU
AH,SAS-200/571 AU Monopole rod antenna. Frequency range 100Hz~60MHz. Active unit with
AH,SAS-571 MY battery power. Rod height 220mm~1.09m. Ground plane 450 x 450mm.
Double ridge guide horn antenna. Frequency range 700MHz~18GHz. Antenna factor 0~24.
Continuous power 300W. Impedance 50Ω 200V/m max radiated field. Type
N(f) connector.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 19
RF & MICROWAVE
Field Strength Meters & Antennas
AH Systems 300MHz ~12GHz Antenna System Holaday HI-3004 Field Strength Meter
AH,ANTENNA AU HOL,HI-3004 AU
Log periodic antenna system. Comprises two antennas: A: 300MHz~1.8GHz, Isotropic broadband field strength meter designed primarily to measure
power handling 1kW, antenna factor 15~32dB, B: 1~12GHz, power handling low level fields for EMI/EMC studies. Meter scale calibrated in v/m, with
10W, antenna factor 25~44dB. Complete with tripod. pointer deflection proportional to v2/m2. Supplied with HSE high sensitivity
E-field probe & STE E-Field probe. HSE probe has 4 ranges, 1v/m ~30v/
Anritsu Dipole Antenna Kit mFS, 0.5~1,500Mhz. STE probe has 4 ranges 100v/m~3,000v/mFS,
ANR,ANTENNA AU
0.5Mhz~6Ghz. Recorder output (0~1Vdc).
Comprises types MP534A and MP651A antenna covering 25~520 &
470~1,700MHz. Complete with tripod type MB9A and coaxial cable. WG ESM-20 Radiation Meter
WG,ESM-20 AU
Anritsu 2.4/5.8GHz WIFI 802.11A/B/G Antenna Personal monitor and leakage detector for high frequency electromagnetic
ANR,WIFI-ANTENNA
fields. Simultaneous E and H field measurements with audible and visual
High precision antenna set for wireless network test applications (802.11A/B/
alarms. Frequency range H field 1 MHz to 1 GHz; E field 1 MHz to 40
G, 11Mbps &54 Mbps). Includes 2.4GHz and 5.8GHz antennas with reverse
GHz. Operation as personal monitor with compensation for human body
SMA connectors. Also includes precision reverse SMA to N type adapter to
absorption, or with isotropic detection for RF leakage sensing and simple
fit standard test equipment.
four-level measurement using LED indicators. Battery powered - battery life
Rohde & Schwarz HL013 80MHz~1.3GHz Log-Periodic Antenna over 200 hours.
RS,HL013 AU
Narda 8217 Microwave Oven Survey Meter
Complete with tripod.
NAR,8217 AU
Holaday HI-3002 Field Strength Meter Microwave oven survey meter complete with beaker and thermometer for
HOL,HI-3002 AU oven power measurement. Calibration frequency 2.45GHz. Measurement
Isotropic RF radiation monitor. E-field & H-field probes spanning range 0.5~10mW/cm2. Battery operated.
500kHz~6GHz (E-field) & 5~300MHz (H-field). Operates from batteries.
Robin Electronics TX90 Microwave Leakage Detector
ROB,TX90 AU
Microwave leakage detector. Eight dipole analogue meter reading. Ranges
1~10mW/sqcm & 0·1~1mW/sqcm. Display analogue moving coil. Power
density accuracy ±1dB. Probe area 2cm2. Supplied with a manufacturers
certificate of calibration traceable to National Standards. Powered by 9V
alkaline battery.
Protek 3201 RF Analyser/Signal Meter
PRO,3201 AU
RF signal analyser and level meter. Provides spectrum display up to
2.06GHz, audio output, level measurement, and frequency measurement.
Inbuilt antenna. Frequency range 100kHz~2.06GHz with frequency steps
from 5kHz. Modulation types narrow and wide band FM, AM, and SSB.
Level measurement min frequency - narrow band FM 1MHz, wide band FM,
AM, SSB 10MHz. Bandwidth - narrow band FM 12.5kHz, wide band FM
180kHz, AM & SSB 2.4kHz. Frequency measurement 9MHz~2.06GHz.
Narda 8616 Radiation Hazard Monitor Input impedance 50Ω.
NAR,8616 AU
Radio frequency radiation monitor complete with probes. Battery operated
with analogue meter and recorder output (3Vdc full scale). Probe type
8623B has a calibrated frequency range of 300MHz~26GHz over a range
of 0.05~100mW/cm2. (Frequency range up to 8GHz is calibrated to NATA
standard, above 8GHz calibration is to manufacturer’s specifications).
Probe type 8633 has a frequency range of 10~300MHz over a range of
0.05~100mW/cm2.
SE International Monitor 4 Nuclear/X-Ray Monitor
SE,MONITOR 4 AU/MY
Alpha, Beta, Gamma & X-ray radiation monitor. Meter, LED & audible
indication. Range; 0~0.5, 5, 50mR/hr, 0~500, 5,000, 50,000CPM, 0~5, 50,
500µSv. Energy sensitivity Alpha 2.5MeV, Beta 50KeV, Gamma & X-ray
10KeV. Battery operated.
Protek 3290 RF Analyser/Signal Meter 2.9GHz
SE International Monitor MC1K Radiation Survey Meter PRO,3290 AU
SE,MCIK AU RRF signal analyser and level meter. Provides spectrum display up to
Gamma & x-ray radiation monitor. Meter, LED, and audible indication. 2.9GHz, audio output, level measurement, and frequency measurement.
Ranges 0.1~1,000mR/h & 0.01~10mSv/h full scale. Battery operated. Inbuilt antenna. Frequency range 100kHz~2.9GHz with frequency steps
from 5kHz. Modulation types narrow and wide band FM, AM, and SSB.
Level measurement minimum frequency - narrow band FM 1MHz, wide band
FM, AM, SSB 10MHz. Bandwidth - narrow band FM 12.5kHz, wide band FM
180 kHz, AM & SSB 2.4 kHz. Input impedance 50Ω.

Modulation Meters
Marconi TF2304 Auto AM/FM Modulation Meter
MAR,TF2304 AU
Automatic operation. Frequency 9~12.5MHz & 18~1,000MHz, FM deviation 8 ranges, 1.5~150kHz FS AM depth 3 ranges, 10~30~100%.

20
RF & MICROWAVE
EMC Test Equipment
Laplace RF Absorbing Clamp Schaffner 438 30kV Static Discharge Generator
LAP,RF-CLAMP AU SFN,438 AU
For measurement of emissions from power and other lines to CISPR and Generates an electrostatic charge in a range from 2~30kV. This instrument
VDE standards. Frequency range 30 MHz~1GHz. Output 50Ω. is in a ‘gun’ form. Removable discharge network which can be interchanged
with other (optional) impedance networks. Performs test to IEC1000-4-2
Laplace SA1000 EMC Test System standards.
LAP,SA1000 AU
Comprises PC controlled spectrum analyser 10kHz~1.1GHz, SA1020 pre-
amplifier, RF200 broadband antenna 30MHz~1Hz, TTI LISN1600 LISN,
and RF100 E-field & H-field probes. Supplied with notebook PC and EMC
> NEW
Schaffner Automated Step Transformer
SFN,INA-6502 AU
software. Integrated function unit to Modula system. Power line dips to 0%, 40%, 70%
and 80%. Complies with EN/IEC 61000-4-11. Includes EUT power control
> NEW
Schaffner Modula-6100 Immunity Test System
SFN,MODULA 6100 AU
switch.
Schaffner BestPlus B-1
Multifunction generator to simulate electro-magnetic field interference effects SFN,BEST+ AU
for immunity testing in conformity with international, national and in house EMC, ESD, PQT, Burst and Surge Immunity generator simulators. Includes
standards including the new IEC/EN standards. Generates Interference ESD generator/gun.
pulses such as burst and surge and power quality simulations.
Schaffner NSG-420 RF Current Immunity Tester
SFN,NSG-420 AU
Provides pre-compliance testing to IEC 801-3 and IEC 801-6. Clamp coupled
to power, data, and signal cables of a device under test. Injects noise signal
from 100kHz~100MHz with a level response from 1MHz~10MHz. AM &
FM modulation of source from a 1kHz oscillator source or an external input.
Indication of signal current from source or existing signal. Also dc recorder
output of this signal. Cable size up to 10 x 22mm. Operates for 1h on 4AA
alkaline batteries.

Communications Test Sets


Marconi 2945 Communications Test Set Marconi 2945A Communications Test Set
MAR,2945 AU MAR,2945A AU
Output frequency range 400kHz~1.05GHz. Input frequency range to Output frequency range 400kHz~1.05GHZ. Input frequency range to
modulation monitor and spectrum analyser 100kHz~1.05GHz. Tracking modulation monitor and spectrum analyser 100kHz~1.05GHz. Tracking
generator with offset tracking inbuilt. Power measurement to 150W. Full generator with offset tracking in-built. Power measurement to 150W. Full
duplex operation. AMPS cellular option included. Spectrum analyser with duplex operation. Spectrum analyser with 1kHz resolution. AC mains,
1kHz resolution. AC mains, external 11~32V and internal battery operation. external 11~32V dc on some assets, and external battery operation. RS232C
RS232C remote control interface. remote control interface.
HP 8920A Communications Test Set
HP,8920A AU
RF Communications Analyser test set. Frequency range of 250KHz~1GHz.
Includes an AM/FM signal generator, AM/FM modulation analyser, duplex
offset generator, SSB demodulator, RF power meter, frequency counter, ac/
dc voltmeter, SINAD meter, Distortion meter, oscilloscope and two variable
audio sources. Includes Spectrum analyser with tracking generator. Antenna
& microphone are included.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 21
RF & MICROWAVE
Power Meters & Sensors - RF
Model Type Frequency Power
*100kHz~50GHz *100µW~25mW
HP,E4418A Digital Power Meter
*75GHz~110GHz *-70dBm~44dBm
*100µW~25mW
HP,E4418B-001 Power meter, high speed, single channel *9kHz~110GHz
*-70dBm~44dBm
*100µW~25mW
HP,E4419B-001 Power meter, high speed, dual channel *9kHz~110GHz
*-70dBm~44dBm
HP,8508A Vector voltmeter 100kHz~2GHz 90dB range
BIR,43 RF Thru-line power meter ∆450kHz~2.3GHz
∆100mW~10kW
BIR,4391 In-line digital RF power meter According to element

1.8MHz~32MHz
BIR,4421 In-line RF power meter 300mW~1kW
25MHz~1GHz
0.4~1GHz
BIR,APM16 Average reading power meter for PCD GSM & CDMA 2.5W~25W
1.7~2.2GHz
BIR,ELEMENT Elements for Model 4391 ∆According to element
MAR,6970 Digital power meter ∆According to sensor
COL,DC1500A In-line RF power meter dc~0.5 GHz 100W
WAV,FIT RF power & VSWR meter 70MHz~1GHz 20mW~50W
R&S,NRT-Z43-Z44 Directional power meter 30W
200MHz~4GHz
R&S,NRT Power reflection meter 30W
* Sensor Dependant
# Element Dependant

Model Type Frequency Power


HP,8481A 1µW~100mW
10MHz~18GHz
HP,8484A 0.1nW~10µW
HP,E9300A 0.1nW~100mW
Power Sensor
HP,E9300B 10Mhz~18GHz 0.1nW~25mW
HP,E9300H 10nW~1W
HP,8485D 50MHz~26.5GHz 100pW~10µW
RS,FSH-Z1 1.8MHz~26.5GHz 300mW~1kW

> NEW
HP 8508A Vector Voltmeter
HP,8508A AU
Agilent E4418B Series Power Meter
HP,E4418B-001
Digital power meter. Battery or mains powered. 100µW - 25W (-70dBm
AU

Narrowband measuring technique gives a range of over 90dB and a ~+44dBm), 9kHz~18GHz (depending on power sensor), 4 digit display
sensitivity of 10µV to trace the smallest signal. Measures the phase - watts, dBm, dB (rel). Power sensor required, select and specify when
difference between its two input channels with at least 0.1º resolution over ordering.
a full 180°~-180° range, so they can be used for another complete set of
measurements such as electrical length, phase distortion, or impedance.
100kHz~1GHz with high impedance inputs. 300kHz~2GHz with 50Ω inputs.
Circuit probing to facilitate the design process. Easy programming for ATS’s.
Narrowband measurement capability for high sensitivity applications.

22
RF & MICROWAVE
Power Meters & sensors - RF
HP E4419B Series Dual Channel Power Meter Bird 4391A RF Digital Thru-Line Power Meter
HP,E4419B-001 AU BIR,4391A MY
Battery or mains powered dual channel digital power meter. 100µW~25W Digital display, microprocessor-based operation and simplified, push-button
(-70dBm~+44dBm), 9kHz~18GHz (depending on power sensor), 4 digit control. Wattmeter is suited to telemetry, two-way communications, avionics,
display - watts, dBm, dB (rel). Power sensor required, select and specify radar, and standard radio and TV applications. Freq. 0.45~2700MHz.
when ordering. Power 100mW~10kW with 20% over-range. Reads forward and reflected
CW or FM power in watts or DBM. Calculate SWR, return loss in dB and %
modulation.

Bird 4421 Wide Range Power Meter


BIR,4421 AU
Complete with 4021 sensor 300mW~1kW, 1.8~32MHz & 4022 sensor
300mW~1kW, 25MHz~1GHz. Max input 1.2kW. VSWR range 1~2.
Measures forward & reverse power in W or dBm, VSWR, and return loss
in dB. Digital display. Operates from ac mains or internal rechargeable
batteries.

Bird APM16 Power Meter


BIR,APM16 AU
Average reading power meter intended for PCS, cellular (including CDMA,
Hioki 3134 Digital Power Meter GSM) and general purpose applications. Includes in-line elements for 2.5 &
HIO,3134 MY 25W, frequency ranges 0.4~1GHz, 1.7~2.2GHz. Battery operated.
AC line power meter, 3 phase W/V/A 1000kw uses two-wattmeter method for
3 wire systems. Can do 4 wire systems. Digital display plus analogue O/P Marconi 6970 Digital Power Meter
for all display values V/A/W/VAR. Watts/VAR can both be O/P together to MAR,6970 MY
derive power factor. Supplied with 2x CT’s 3x volts I/P leads in case. Ni-Cad battery operated with digital display. Complete with AC adaptor.
Requires sensor. Sensors available for 10MHz~26.5GHz frequency range.
Hioki 3136 Clamp-on Power Meter
HIO,3136 MY
Marconi 6970 Digital Power Meter
Power meter 3ph, 4 wire. FSD 200/1000kW 1kA 600/3V 200/1000 kVAR
MAR,6970 AU/MY
recorder O/P 2V/50Ω 40~500Hz complete with 3 x CT’s 9002 unit will
NiCd battery operated with digital display. Complete with ac adaptor.
measure 1ph V, A & W. VA & VAR will need to be calculated. On 3ph it will
Requires sensor. Sensors available for 10MHz~26.5GHz frequency range.
measure VAR, VA will need to be calculated.
Coline DC1500A VSWR/Power Meter
Fluke 36 True RMS ac/dc Clamp Meter COL,DC1500A AU
FLU,36 MY
Frequency range: dc~1.5GHz. Accuracy ±5% of reading. Max continuous
Jaws accept 1 x 750 MCM (1.2 (3mm)) cable or 2 x 500 MCM, (0.98
power 100W, intermittent 200W. Resolution 0.1W. VSWR measurement
(24.6mm)) cables up to 38mmØ. True-rms responding. Display 3.5 digit,
30MHz~1.5GHz. Usable to 10MHz. Power range for VSWR varies with
2000 count. Rugged design. AC current(45~400Hz), range 600A/200A,
frequency. Min 5W @ 30MHz, 30mW at 1.5GHz. Max 200W @ 30MHz,
resolution 1A/.1A, accuracy 10~600A ±(2%+3) or 0.5~200A ±(2%+5), crest
50W @ 1.5GHz. Range 1.00~19.99. 50W RF load included.
factor 2</-CF</-3, add 2% Rdg, overload protection, 600A continuous (CF</-
3). DC current range 1kA/1kA/200A, resolution 1A/1A/1A, accuracy 0~600A
Wavetek FIT RF Power and VSWR Meter
±(1.9%+4), 600~1000A ±(3%+3), 0~200A ±(1.9%+7), overload protection
WAV,FIT NZ
1kA. AC volts(45~400Hz), range 600V/200V, resolution 1V/1V, accuracy
Portable RF power meter with VSWR, volts and resistance measurements.
±(1.5%+3), crest factor <3 (pk voltage ±933V), overload protection 1200V
Frequency range is 70MHz~1GHz. Power range is 20mW~50W, resolution
rms. DC volts range 600V/200V, resolution 1V/1V, accuracy ±(1.0%+3),
is 10mW. Accuracy is ±0.5dB at 1W. VSWR range is 1.2~10. Voltage
overload protection 1200V rms continuous. Manual ranging. Protective
measurement is 0~30V, resolution is 30mV. Resistance measurement is
case & TL75 hardpoint test leads. Continuity beeper under 50Ω.
0.2~1kΩ, resolution is 0.1.
Bird 43 Power Meter Rohde & Schwarz NRT-Z43-Z44 Directional Power Meter
BIR,43 MY
R&S,NRT-Z43-Z44 MY
RF thruline power meter. Requires bird element of specified frequency and
Measures power and reflection under operational conditions. Wide
power. Measures forward and reflected power by reversing the element.
frequency range from 200(400)MHz~4GHz covers all relevant frequency
Bird RF Element for Model 43 Power Meter bands. Measurement method is compatible with all common analog and in
BIR,ELEMENT AU particular digital modulation standards: GSM/EDGE, 3GPP (W-/TD-CDMA),
BIR,ELEMENT-LF MY CDMA (IS-95), CDMA2000, PHS, NADC, PDC, TETRA, DECT, DAB, DVB-T
BIR,ELEMENT-HF MY and many more.
Bird watt meters. Available in various power and frequency ranges.
Rohde &Schwarz NRT Power Reflection Meter
Bird 4391 In-line Digital RF Power Meter RS,NRT MY
BIR,4391 AU Measures power and reflection under operational conditions. Wide
RF power meter/analyser with pulse power capability covering frequency range from 200(400) MHz ~4GHz covers all relevant frequency
0.45~2,300MHz at a power of 100mW~10kW according to the elements bands. Measurement method is compatible with all common analog and in
selected (elements rented separately). Measures peak pulse, peak particular digital modulation standards. GSM/EDGE, 3GPP (W-/TD-CDMA),
envelope, & CW power. Pulse parameters: minimum width 0.8µs, CDMA (IS-95), CDMA2000, PHS, NADC, PDC, TETRA, DECT, DAB, DVB-T
100~2,300MHz, 1.5µs, 26~99MHz, 15µs, 2~25MHz; minimum repetition and many more.
rate 25pp/s & minimum duty factor 1 part in 10,000. Measures VSWR and
percentage modulation. Operates from ac mains and rechargeable batteries.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 23
RF & MICROWAVE
Power meters & sensors - RF

> NEW
HP E9300A Power Sensor for HPE4416/18 Power Meters
HP,E9300A AU/MY
HP E9300H Power Sensor 10nW~1W, 10MHz~18GHz
HP,E9300H
Power sensor for HP EPM series power meters. E-series Average Power
AU

For HPE4416/HPE4418 power meters. 10MHz~18GHz frequency range. Sensor. 10 MHz~18 GHz, 10nW~1W (-50dBm~+30dBm).
1nW~100mW (-60~+20dBm) power range. 320mW max average power
handling (+25dBm), 2W (+33dBm) peak power (<10usec). N-Type HP 8481A 10MHz~18GHz Power Sensor for HP43X Series
connectors. Meters
HP,8481A AU
For HP436A, HPE4418B & HPE4419B. 10MHz~18GHz, 1µW~100mW.

HP 8484A 10MHz~18GHz Power Sensor


HP,8484A AU
Power sensor 10MHz~18GHz, 0.1nW~10µW. Complete with HP,11708A
30dB reference attenuator.
Marconi 6910 Power Sensor
MAR,6910 MY
Frequency range 10MHz~20GHz. Power range -30dBm~20dBm
(1μW~100mW). Max RF i/p 25dBm (300mW) CW 42dBm (15W) peak
> NEW
Agilent Power Sensor 1µW~25W, 10MHZ~8GHz
HP,E9300B AU
for 2μs. Sensing element semiconductor thermocouple. VSWR 1.25
10MHz~30 MHz, 1.1 30MHz~2GHz, 1.18 2~16GHz, 1.28 16~18 GHz, 1.4
typical 18~20GHz. Linearity factor provided with sensor. Accuracy ±0.5% at
Power sensor for HP EPM series power meters. E-series average power
25C between 10 & 20dBm. Improves by a factor of 10 for each lower rang.
sensor. 10MHz~18 GHz, 1µW~25W (-30dBm~+44dBm).
Calibration factor provided with sensor. Accuracy uncertainty provided with
sensor. Resolution 0.01%. RF connector precision N-type (M) 50Ω.

Marconi 6912 Power Sensor


MAR,6912 MY
Frequency range 30kHz~4.2GHz. I/p power range 30dBm (1μW) to 20dBm
(100mW).

Marconi 6913 Power Sensor


MAR,6913 MY
Frequency range 10MHz~26.5GHz. I/p power range 30dBm (1μW) to 20dBm
(100mW). Max 25dBm (300mW) CW, 42dBm (15W) peak for 2μs. Sensing
element semiconductor thermocouple. VSWR 1.40 10MHz~50MHz, 1.15
> NEW
HP 8485D Power Sensor 100pW~10uW, 50MHz~26.5GHz
HP,8485D AU
50MHz~100MHz, 1.10 100MHz~2GHz, 1.15 2~12.4GHz, 1.20 12.4~18GHz,
1.25 18~26.5GHz. Calibration factor provided at 1GHz intervals (500MHz
intervals above 20GHz) with each sensor. Accuracy uncertainty provided
Power Sensor 100pW to 10uW, 50MHz to 26.5GHz.
with each sensor. Resolution 0.01%. Linearity factor accuracy ±0.5% at
100mW, decreasing by 0.005% per 1mW.

Marconi 6920 Power Sensor


MAR,6920 MY
High sensitivity diode sensor. Frequency range 10MHz~20GHz. I/p power
range 70dBm (0.1nW) to -20dBm (10μW), max 26dBm (400mW) CW
+30dBm (1W) peak for 2μs. Sensing element Shottky barrier diode. VSWR
1.4~1.2 10~40MHz, 1.20 40MHz~10GHz, 1.35 10~18GHz, 1.40 typical
18~20GHz. Calibration factor provided at 1GHz intervals with each sensor.
Accuracy uncertainty provided with each sensor.

Marconi 6923 RF Power Sensor


MAR,6923 MY
High sensitivity diode sensor. Frequency range 10MHz~26.5GHz. I/p
power range -65dBm (0.3nW) to -20dBm(10μW), max 26dBm (400mW)

> NEW
Rohde & Schwarz Power Sensor for RS,FSH 10MHz~8GHz
RS,FSH-Z1 AU
CW, +30dBm (1W) peak for 2μs. Sensing element Shottky barrier diode.
VSWR 1.4 10~40MHz, 1.15 40~100MHz, 1.12 0.1MHz, 1.17 2~8GHz, 1.30
8~18GHz, 1.50 typical 18~26.5GHz. Calibration factor provided at 1GHz
Power sensor for RS,FSH 10MHz~8GHz. 200pW~200mW intervals with each sensor. Accuracy uncertainty provided with each sensor.
(-67dBm~23dBm). Resolution 0.01%. Linearity factor provided with each sensor. Accuracy
±1% between -30 & -20dBm. RF connector type N (M) precision 50Ω.

24
RF & MICROWAVE
RF Attenuators
Model Type Attenuation (dB) Frequency (GHz) Power Max (W)
HP,8494B-8496B 121
HP,8494B 11
Coaxial step attenuator dc~18
HP,8495B 70 1
HP,8494/5B 81
HP,8495D Step attenuator 70 dc~26.5
WEI,33-10-34 10 dc~8 25
WEI,34-30-34 30 dc~4 24
WEI,46-03-34 3 50
Fixed
WEI,46-06-34 6
dc~18
WEI,46-10-34 10 25
WEI,46-20-43 20
WEI,82-30-34 Coaxial attenuator 30 dc~3 1000
WEI,AS6 Calibrated attenuator 3
WEI,AS20 Variable attenuator 30 dc~26.5 2
WEI,M2020 Attenuator 20 dc~18
BIR,25A-10 Fixed 10 dc~4 25
NAR,705-69 Attenuator 30 dc~18 25

Weinschell 33-10-34 25 W 10dB 8.5GHz RF Attenuator Weinschell AS6 Calibrated Attenuator Set
WEI,33-10-34 AU WEI,AS6 MY
10dB, 25W, dc~8GHz. Type N connectors. Frequency range DC-18GHz, set consists of 4 different nominal value 3, 6,
10 & 20dB. Connector type N per mil-STD-348, power rating 5W.
Weinschell 34-30-34 25W 30dB 4GHz RF Attenuator
WEI,34-30-34 AU Weinschell AS20 Precision Attenuator Set
30dB, 25W, dc~4GHz. Type N connectors. WEI,AS20 AU
DC~26.5GHz. Attenuator values 6,10,30 dB. Average power 2W.
Weinschell 46-03-34 50W 3dB 18GHz RF Attenuator 3.5mm connectors.
WEI,46-03-34 MY
Weinschell M2-20 Attenuator
Weinschell 46-06-34 50W 6dB 18GHz RF Attenuator WEI,M2-20 MY
WEI,46-06-34 MY
20 dB attenuator. DC to 18GHz, double male N type
DC - 18GHz, 6 dB, average power 25W, 200W peak. Type N connector.
HP 8494B/8496B Attenuator Set 121dB x 1dB
Weinschell 46-10-34 50W 10dB 18GHz RF Attenuator HP,8494B-8496B AU
WEI,46-10-34 MY
Coaxial step attenuator set. DC-18GHz. 0.11dB in 1dB steps and 10-110
DC - 18GHz, 10 dB, average power 25W, 200W peak. Type N connector.
dB in 10dB steps. Comprises a connected set of types 8494B & 8496B with
Weinschell 46-20-43 25W 20dB 18GHz RF Attenuator 11716A rigid interconnect kit. Type N(f) connectors.
WEI,46-20-43 AU/MY
HP 8494B 11 x 1dB 18GHz Coaxial Step Attenuator
DC~18GHz, 20dB, 25W. Type N connectors.
HP,8494B AU

> NEW
Weinschel 82-30-34, 30dB 1000W 3GHz Coaxial Attenuator
WEI,82-30-34 AU
DC~18GHz. 0~11dB in 1dB steps. 1W average power handling. Option
001. Type N(f) connectors.
HP 8495B 70dB x 10dB Coaxial Step Attenuator
30dB 1000W 3GHz Coaxial Attenuator. DC to 3GHz.
HP,8495B AU
DC~18GHz. 0~70dB in 10dB steps.
HP 8494/5B Coaxial Step Attenuator Set 81dB x 1dB
HP,8494/5B AU/MY
DC~18GHz. 0~11dB in 1dB steps. 11~81dB in 10dB steps. Comprises a
connected set of types 8494B & 8495B. Type N(f) connectors.
HP 8495D 70dB 26.5GHz Step Attenuator
HP,8495D AU/MY
70dB step attenuator in 10dB steps. Frequency range dc~26.5GHz. Max
continuous power 1W. Note attenuator uses 3.5mm connectors.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 25
RF & MICROWAVE
RF Attenuators
BIRD 25-A-MFN-10 10dB 25W 4GHz ATTENUATOR Narda 705-69 69 x 1dB GHz Attenuator
BIR,25A-10 AU NAR,705-69 MY
RF Attenuator, DC~4GHz, 10dB, 25W, . Step Attenuator. 0 - 69dB in 1dB steps. Frequency range DC - 18GHz
Bird 808 RF Co-axial Resistor 25W 50Ω
BIR,8080 MY
50Ω, 25 W, DC-3500MHZ. Dummy Load.

Filters
Krohn-Hite 3550 Bandpass Filter
KRO,3550 AU
Band pass, band reject, low pass, high pass filter. Frequency range 2Hz~200kHz. Bandwidth 2Hz~3MHz. Max attenuation 62dB. Slope 24dB per octave.

RF Accessories
HP 85021A RF Directional Bridge HP 11692D Dual Directional Coupler
HP,85021A AU HP,11692D MY
For HP,8757A scalar network analyser. Frequency range 2~18GHz.
HP 11667A Power Splitter HP 778D Dual Directional Coupler
HP,11667A AU HP,778D AU
For HP,8757A scalar network analysers, dc~18GHz, 0.5W max. N (F) Frequency range 100MHz~2GHz.
connector on all ports.
HP 908A Coaxial Termination
HP X281A WR-90, 1-079 to N(F) Adaptor HP,908A AU
HP,X281A AU DC~4GHz. Max power 0.5W average.
8.2~12.4GHz waveguide to type N (F) adaptor.
HP 11852A Min Loss Pad 50 ~75Ω
HP P281B-013 WR-62, 1-089 to Coax Adaptor HP,11852A AU
HP,P281B AU Low SWR min loss pad for use with 50Ω network analysers or other
12.4~18GHz waveguide to type N(f) adaptor. instruments to allow connection to 75Ω cables and devices.
HP S281A WR-284 to N(F) Adaptor Radiall R-404850 RF Termination
HP,S281A AU RAD,R-404850 AU
2.6~3.95GHz waveguide to type N (F) adaptor. RF load. 100W, 50Ω, dc~4GHz. Type N (M).
RF Connector Kit N, BNC, TNC, SMA, APC7 Flann 1713320 Waveguide Directional Coupler
TR,RF-CONN AU FLA,1713320 AU
RF connection adaptors. Comprises 10 couplers with interchangeable 20dB.
connectors; 3 x N, BNC, SMA, & 1 x TNC, all (M) & (F). Includes APC~7 to
N (F) adaptor.
LOW FREQUENCY

LF Signal Generators
Tektronix ASG100 Audio Generator Genrad 1390B Random Noise Generator
TEK,ASG100 MY GR,1390-B AU/MY
Dual CH for stereo applications. Balanced i/p & o/p. Connects in-line for Frequency range 5Hz~5MHz, range selectable 20kHz, 500kHz & 5MHz.
easy test signal insertion. Quick identification of insertion pt with voice ID. Output level 3V, 2V, 1V for each frequency range respectively. Gaussian
Short duration audio test sequence for rapid automatic checkout of audio output. Frequency response 1dB, 20Hz~20kHz. Pink noise filter optional.
lines. Single button selection of line-up tone. Manual mode allows selection
of freq & amplitude. RS-232 for remote control.

Distortion Analysers
HP 8903B-010-051 Audio Analyser Trend Type 3 Distortion Generator
HP,8903B AU TRE,TYPE 3 AU
Audio analyser for communications and other applications. Measures Distortion generator.
distortion, sinad, signal-to-noise, ac V, dc V, frequency. Low distortion
programmable sine wave source. Frequency range 20Hz~100kHz. Optional
400Hz high pass and CCITT weighting filters fitted.

26
TELEVISION TEST EQUIPMENT
TV Test Equipment

> NEW
Rohde & Schwarz EFA TV Test Receiver 43
RS,EFA43 AU
Tektronix 1741 Vectorscope/Waveform Monitor
TEK,1741
PAL waveform monitor and vectorscope for television and video use.
AU

DVB-T test receiver, fully compatible with the ETS300 744 standard, receives,
Unaohm S20 & Datum 10 Digital TV Meter Combo Meter
demodulates, decodes and analyzes OFDM (orthogonal frequency division
UNA,DATUM10-S20 AU
multiplex) signals. All key parameters for demodulating the receive signal
Comprises S20 Satellite digital and analogue television bit error rate meter
can be selected automatically or manually. Features, 7MHz SAW filter.
and Datum 10 terrestrial digital and analogue television instrument.
6MHz, 7MHz or 8MHz operating bandwidth. 2K or 8K OFDM modulation.
QPSK, 16QAM or 64QAM constellation diagram. 1/2, 2/3, 3/4, 5/6 or 7/8
code rate. 1/4, 1/8, 1/16 or 1/32 guard interval. Hierarchical demodulation.
Reed-Solomon error correction 204/188.

> NEW
Promax TV Explorer Prodig-5
PRO,PRODIG-5 AU
Barco Quasar Modulator
For the installation, maintenance and surveillance of terrestrial, satellite and
BAR,MODULATOR AU
cable TV systems. Automatically provides information about the channels
Digital television signal converter. Rack mounted. Supports a full range of
available in the network and their quality. Displays analogue and digital
variable data rates, signal bandwidths and constellations. Complies with
channel picture. Includes a high resolution spectrum analyser function and
ITU-TJ.83 standards, annex A (DVB), B (open cable) & C Japan. ASI input
MPEG decoding. Foxtel approved.
interface (with active loop-through). Variety of input interfaces available. Bit
stuffing on/off and PCR re-stamping. Static PID filtering. Tuneable or fixed
output RF frequency. IF loop. Front panel RF testpoint (-20dB). 60dBmV
(rms) output level. Front panel LCD and buttons for easy set-up. Full remote
control and diagnostics with ROSA management. Back-up and automatic
level control available with ROSA.

Promax Prolink 4C Premium Analogue/Digital TV Test Set


PRO,PROLINK4C-PREM AU
Measures terrestrial, satellite and cable TV systems including analogue and
digital VHF & UHF bands. Built in colour monitor provides measurement
readout and can be used to display video signal. Measurement functions
include spectrum analysis, direct signal level readout, carrier to noise,
channel power, digital carrier to noise, digital bit error ratio (BER) and digital
QAM constellation. DVB digital TV channel identifier. Logs to PC and
includes software for remote control and channel plan management.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 27
DATA, NETWORK & TELECOMMUNICATIONS
Telecommunications

> NEW Nettest Lite 3000E Signalling Analyser for


Telecommunications Systems
GNE,L3000E-ND AU
Digital Lightwave NIC 2.5G STM16 2.5Gb SDH Test Set
DLW,NIC2.5G
Portable analyser with touch screen PC. Testing at SDH rates of
AU

Simultaneous monitoring in both directions of 2Mb/s PCM lines. Tests framed STM0/1/4/16 (52,155,622Mb/s & 2.5Gb/s). Tests PDH at E1,E3, E4, DS1 &
Nx64 Kb/s & unframed 2Mb/s PCM systems. Remote operation with MS DS3 (2,8,140,1.5 & 45Mb/s). Dual wavelength (1310/1550nm). SC Optical
Windows. Frame Relay installation testing, trouble shooting & decode. All- connectors. Tests include BERT, level, protocol decoding & analysis and
layer protocol analysis and decode options for ISDN. ISDN Call Emulation ATM analysis. Complete in portable hardcase.
option provides the necessary functionality for testing ISDN connections,
Digital Lightwave NIC10G STM16/64 SDH Analyser
can setup and receive ISDN calls with user-specified parameters.
DLW,NIC10G AU
Network information computer. Verifies and qualifies the performance of
OC-192c/OC-48c SONET, STM-64/STM-16 (10/2.5Gbps) SDH and DWDM
telecommunications networks. Optical interfaces (1550/1310nm for STM16
& 1550nm for STM64). Includes concatenated payload support and OC-
48/STM-16 add/drop. 10.4” active matrix touch screen GUI operation.
Measures optical power and frequency. PCMCIA slots for memory cards
and peripherals.

Anritsu ME538MLA TX & RX Microwave Link Analyser


ANR,ME538M AU
Measures group delay, modulator/demodulator linearity & sensitivity,
differential gain & phase, IF/BB amplitude response, IF/BB return loss,
frequency spectrum & deviation, am to pm conversion coefficient, power,
gain attenuation and dc characteristics. Features: LED display, autorange
CRT, push button parameter selection and remote monitoring. 70/140MHz
bands: 83.333, 250, 500kHz & 2.4, 3.58, 4.43, 5.6, 8.2, 12.39MHz.
Digital Lightwave NICPlus 10G SDH Tester with Gb Ethernet
Nettest EPE06/7 2,8,34,140 MPPS BERT DLW,NICPLUS10G AU
GNE,EPE06/7 AU Portable Gb/OC-192/STM-64 Network Information Computer (5 slot
PCM BERT tester for 2, 8, 34 & 140 Mb PCM systems. Performance chassis). Multirate interface for STS-1 OC-1/3/3c/12/12c/48/48c STM-
according to G.821 with BNC type connectors. For unbalanced inputs. 0e/1e/0/1/1c/4/4c/16/16c and interface for OC-192/192c STM-64/64c with
the ability to monitor down to the STS-1/STM-0 level inside of any supported
Nettest MPA7400 Multichannel Signalling Protocol Analyser optical rate. Use to verify & qualify the performance of SDH & DWDM & GbE
GNE,MPA7400 AU
telecomm networks. Electrical & optical interfaces (1550nm for 10G, all other
Multichannel telecom protocol analyser for detailed analysis of signalling
rates 1310/1550). Includes concatenated payload support & OC-48/STM-16
systems such as SS7. Able to analyse 4 channels at the same time. Some
add/drop. G.709/975 OTU 1 / OUT 2 FEC software installed 10.4 inch active
emulation capability. Additional protocol decodes available on request.
matrix touch screen GUI operation. Measures optical power and frequency.
Unit is currently set up to handle signalling analysis for cellular telephone
PCMCIA slots available for memory cards and peripherals.
exchanges.
Fluke 990DSL CopperPro Telecom Line & DSL Test Set
Trend Aurora Sonata BRA/PRI ISDN Test Set Analyser
TRE,AURORA-SONATA AU
FLU,990DSL AU
BRI/PRI/POTS test set. Provides simulation and monitor capabilities for
CopperPro wide range Plain Old Telephone Services (POTS) fault location
Primary Rate, Basic Rate, and POTS services. Provides decoding of ETSI
and line qualification capabilities. Includes Wideband/TDR option which
ISDN protocols. Has S,U,E1 and RJ11 POTS interfaces. Battery operated
adds high frequency transmission testing and qualification functions for
hand held device.
services like ADSL, HDSL, HDSL2, HDSL4, ISDN, T1, E1 and DDS. TDR
W&G/Acterna IBT-10U Basic Rate ISDN Test Set feature adds precise fault location and analysis. Includes TN2100 remote
WG,IBT-10U AU terminator.
Performs BERT, protocol analysis to level 3 includes both S & U interface.
Features include: NT simulation, telephone and tracer function, X.25 on D
channel and B channel, measurement of supply voltages.
Nettest Lite 3000E Signal Analyser
GNE,L3000E AU
Signaling analyzer for telecommunications systems. Framed Nx64 Kbps
and unframed BERT testing, in-service and out-of-service error performance
measurements G.821/G.826/M.2100. Balanced and unbalanced interface.
Has functionality for G.703, ABIS, SS7, and ISDN for use in both wired and
wireless (cellular GSM) applications. Provides comprehensive test and
measurement of data transmission lines on RS232/V.24 async & sync, X.21/
V.11, V35, RS422/485/449/V.36, RS-530, DCE or DTE. Detailed analysis
and graphical representation on large colour display. Remote operation with W&G/Acterna ANT 20 SDH/PDH Analyser
MS Windows. WG,ANT20 AU
Interfaces for PDH data streams at 2, 8, 34, & 140Mb/s, electrical and optical
interfaces for SDH at STM1 (155Mb/s). Jitter and wander generators and
analyser options are fitted. Internal PC with FDD for transferring results.
Serial, parallel, keyboard and pen interfaces.
Aegis GPset Telecom Pair ID & Intercom
AEG,GPSET AU
For telecommunications cable work. Typically used by Telstra contractors.
Intercom function available on live or unpowered lines.

28
DATA, NETWORK & TELECOMMUNICATIONS
LAN Analysers/Management

> NEW
Fluke Networks Etherscope Gigabit W-LAN Analyser
FLU,ETHERSCOPE-WLAN AU
Airmagnet Portable 802.11 a/b/g Wireless Network Analyser
AIR,AIRMAGNET-TRIO
Portable wireless network analyser for 802.11a, 802.11b and 802.11g
AU

Etherscope extended kit full duplex 10/100/gigabit LAN & WLAN 802.11a/ wireless networks (5 & 2.4GHz). Validates WEP, 802.1x, LEAP, TKIP,
b/g analyser. Handheld analyser for discovery of network elements and MIC, VPNs. Provides security policy validation and intrusion detection.
fault location. Discovers devices by IP subnets, NetBIOS domains, and IPX Detects denial of service attacks. Provides active performance analysis and
networks. VLAN discovery shows interface status, connected host details, identifies and pinpoints WLAN Faults. Includes Find Tool for tracking down
and trending data. Allows measurement of device details and statistics. rogue devices and 70+ configurable alarms with expert advice. Pre-loaded
Complete with cable ID accessory for tracking cable routes. on P3 notebook computer.

> NEW
Fluke Nettool LAN Analyser
FLU,NETTOOL AU
Airmagnet Portable Wireless Network Analyser
AIR,AIRMAGNET-PRO AU
VoIP monitoring. Bi-directional LAN test tool. Diagnose VoIP phone boot- Validates WEP, 802.1x, LEAP, TKIP, MIC, VPNs. Provides security policy
up problems, call control and measure key call quality metrics. Compatible validation and intrusion detection. Detects denial of service attacks. Provides
with IP phones employing either SIP or SCCP call control protocols. VoIP active performance analysis and identifies and pinpoints WLAN Faults.
Log displays call control events, QoS configuration, and call quality metrics. Includes Find Tool for tracking down rogue devices and 70 + configurable
Boot Log displays key boot events such as DHCP address acquisition, DNS alarms with expert advice. Built-in site survey utility with GPS support.
lookup of call servers and gateways, downloading of operating files, and call
Fluke Networks Etherscope Gigabit LAN Analyser
server registration. Inline testing of LANs at the workstation level. Tool is
FLU,ETHERSCOPE-EX AU
plugged in-line between workstation and LAN. Provides indications of NIC
Etherscope extended kit full duplex 10/100/Gb LAN analyser. Handheld
and hub functionality, cable connectivity, and protocol compatibility between
analyser for discovery of network elements and fault location. Discovers
LAN and workstation. Use as a first line fault finding tool for IT departments.
devices by IP subnets, NetBIOS domains, and IPX networks. VLAN
discovery shows interface status, connected host details, and trending data.
Allows measurement of device details and statistics. Complete with cable ID
accessory for tracking cable routes.

Airmagnet Portable 802.11 a/b/g Survey System


AIR,AIRMAGNET-SURVEY AU
Portable wireless network survey tool for 802.11a, 802.11b and 802.11g
wireless networks (5 & 2.4GHz). Provides mapping of wireless network
coverage with optional GPS location facility. Pre-loaded on laptop computer Fluke Optiview Pro Gigabit 10/100/Gigabit LAN Analyser
with approved wireless network card. FLU,OPTIVIEW-GIG AU
FLU,OPTIVIEW NZ
Provides network analysis on 10/100/Gigabit Ethernet networks (multimode
fibre & copper). Active discovery in switched networks, full 7 layer analysis,
fully automatic IP configuration even without DHCP, address-to-name
mapping, packet capture and decode, SNMP device analysis, RMON II
traffic analysis. Gigabit testing capabilities, and basic cable testing (wiremap,
return loss, etc).
HP J3446C 10/100 Ethernet Analyser
HP,J3446C AU
Has RJ45 and AUI ports. AUI ports allow fibre or co-ax connections to be
made with appropriate adaptor (adaptor not supplied). For use with HP
internet advisor undercradles for FDDI or similar analysis.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 29
DATA, NETWORK & TELECOMMUNICATIONS

Network problem solver? Meet your new assistant.


Introducing the EtherScope™ Network
Assistant – your eyes into the network to
help you spot problems and solve them
faster than ever. You don’t have time for trial
and error. Or methods that only provide part
of the picture. That’s why Fluke Networks’ new
EtherScope analyzer, with its immediate
discovery and fast diagnostics, helps you
quickly isolate urgent problems on your gigabit
network as well as those nagging issues that
may be keeping it from performing at optimum
level. Fast. Accurate. EtherScope.

Your network assistant is waiting


to show you what it can do to help
EtherScope™ make your job easier. Just go to
N e t w o r k As s i stant
www.flukenetworks.com/EtherScope
and take a tour of the virtual demo.

N E T W O R K S U P E R V I S I O N TM

LAN Analysers/Management
HP J2524A FDDI Under Cradle W&G/Acterna DA-30 Dual Protocol Analyser
HP,J2524A AU WG,DA-30 AU
For the HP,J2302A or HP,J2523A/B. Includes TP/PMD on STP/DB-9 or Easy to use Windows-based interface with in-built trackball. Provides
UTP/RJ-45, 32Mb data. measurement of physical characteristics of interfaces, protocol analysis of
LAN and WANs, testing of LAN/WAN interconnection devices, simultaneous
HP J2523A Ethernet/Token LAN Analyser analysis of any combination of LANs and WANs. Ethernet and Token Ring
HP,J2523A AU
interface complete with all major layer protocol suites. WAN configuration:
Housed in a ruggedised laptop style colour computer. Includes HP’s latest
V.35, X.21 with “high speed” WAN feature module allowing speeds up to
Drill Down Expert Software.
2Mbps. Includes 16/4Mbps Token Ring interface, Ethernet,HS-WAN, V35-
Network General Sniffer - Ethernet /Token Ring V28 & X21 interfaces. PAM module included.
NG,SNIFF-COMB AU
W&G/Acterna Domino Gigabit
Housed in a colour Toshiba T6600. Analyser provides 3 applications for
WG,GIGABIT AU
network analysis and monitoring. Protocol interpretation for over 140
For monitoring, troubleshooting, and simulation of Gigabit Ethernet networks.
protocols, monitoring features, and expert analysis to help identify LAN
Provides full line rate, full duplex analysis of Gigabit Ethernet networks. All
problems. Oracle database decodes also available.
transmit, capture, filtering, and statistics are provided at full line rate. Expert
Network General 10/100Mb/s Ethernet Protocol Analyser analysis software provides easy diagnosis of network faults, and decodes
NG,SNIFF-10/100 AU over 300 protocols. Link configuration status is detected automatically and
10mbps and 100mbps Ethernet protocol analyser for 10/100 base equipment auto configures itself to suit the detected status. Provided with
T networks. Unit supplied with RJ45 connections only. hot swappable modules for single mode and multi mode fibre interfaces
(LX & SX interfaces). Complete with laptop computer configured for the
Network General Sniffer WAN Interface analyser.
NG,SNIFF-WANPOD AU
Enables the Network General Sniff-Pro98 to perform WAN as well as LAN
analysis. With interface and cables for RS232/V24, V35, RS449/422 and
X.21. Must be used with NG,SNIFF-PRO98. Performs E1/ISDN primary
rate analysis.

30
DATA, NETWORK & TELECOMMUNICATIONS
LAN/WAN Analysers
Nettest Winpharaoh LAN/WAN Analyser Spirent Netcomm Smartbits SMB600 Mainframe
GNE,WINPHARAOH AU SPI,SMB600 AU
Capable of 10/100Mbps ethernet and up to 2Mb WAN with the following Mainframe for router test system for determining router and network
interfaces: V.35, RS-232, RS-449, EI and V.11. PRI and BRA ISDN ability. performance including latency, latency variation and jitter. Can be used to
Report writing software installed for quick overview of network status. load network with specific definable traffic to determine routing performance
and discover throughput bottlenecks. Supplied with standard software and
Nettest Winpharoah 2 LAN/WAN Analyser 30 version of Smartflow application. Requires appropriate interface cards.
GNE,WINPHARAOH2 AU
Capable of 10/100Mbps Ethernet and up to 2Mb WAN with the following Spirent Smartbits LAN-3101A interface for SMB600/6000
interfaces: V.35, RS-232, RS-449, and V.11/X.21. Has BERT testing Chassis
for WAN. Report writing software installed for quick overview of network SPI,SMB600-3101A AU
status.
Spirent Smartbits LAN-3201B Gigabit card for SMB600/6000
Spirent/Netcomm Smartbits SMB200 Router Tester SPI,SMB600-3201B AU
SPI,SMB200-10/100 AU
Spirent Smartbits LAN-3310A 2Port Gigabit Card for
4 port 10/100 ethernet/STM1 ATM system for determining router performance
SMB600/6000
including latency, latency variation and jitter. Can be used to load network
SPI,SMB600-3310A AU
with specific definable traffic to determine routing performance and discover
throughput bottlenecks. System includes 4 x ML7710 10/100 interface Spirent Netcomm Smartbits SMB6000 Mainframe
cards. SPI,SMB6000 AU
12 card Mainframe for router test system for determining router and network
performance including latency, latency variation and jitter. Can be used to
load network with specific definable traffic to determine routing performance
and discover throughput bottlenecks. Supplied with standard software
and 30D version of Smartflow application. Requires appropriate interface
cards.

WAN Analysers
HP 4951C 19.2Kbps Protocol Analyser HP J2302A 2Mbps WAN Analyser
HP,4951C AU HP,J2302A AU/NZ
Serial data and protocol analyser. 50~19,200 baud data transfer rates WAN analyser from 50b/s~2.048Mb/s. Internet Advisor CEPT-E1 and V
for monitoring, simulating and triggering. Data codes: ASCII, EBCDIC, series WAN protocol analyser. Includes; RS232/V24, V35, RS449, and
BAUDOT, six bit transcode (SBT), IPARS and EBDIC. Protocols: X.25. BSC, CEPT-E1 analysis to 2Mb/s with BNC connectors. ISDN primary rate
HDLC, SDLC, IPARS and user definable. Error checking: CRC-CCITT, analysis available with HP,18284A pod. Full monitor and decoding of major
CRC-6/12/16, LRC, parity and block error rate testing (BERT), 5, 6, 7 or 8 protocols over any channel. Fractional channel or full CEPT-E1. Complete
bit per character parity, 1,1.5 or 2 stop bits. Full ASCII keyboard, up to 63 English decodes with customizable displays, real-time stamp for captured
triggers, 32kb buffer memory, 618kb integral microfloppy drive, video output, data or statistics, 100ns resolution. Extensive data-filtering capability.
separate printer output. Complete with HP,18179A RS-232C/V24 interface Real-time statistical analysis, including LAN traffic analysis over WANs.
with full breakout box. 100% capture performance during full line loading. Simultaneous decodes,
statistics, triggers, and filters. Log to hard disk. Full Bit Error Rate tests to
HP 4957A 64Kbps Protocol Analyser 2Mb (including G.821). Over 150 pre-written test included.
HP,4957A AU
Protocol analyser. For up to 64kb/s (option included for asynchronous 8- HP J2302B 2 Mbps WAN Analyser
bit and NRZ/NRZI bit oriented protocols up to 256 kbps). Protocols include HP,J2302B AU
ISDN Q.921, X.25, SDLC, HDLC, IPARS, BSC, ASYNC, and most character Internet advisor. WAN analyser from 50b/s~2.048Mb/s. CEPT-E1 and V
synchronous protocols, (option included for X.21). BERT function. Data series WAN protocol analyser. Includes: RS232/V24, V35, RS449, and
codes ASCII, EBCDIC, BAUDOT, 6 bit transcode (SBT), IPARS, EBCD and CEPT-E1 analysis to 2Mb/s with BNC connectors. ISDN primary rate
HEX. 32 kB non-volatile memory, 786 kB volatile memory, 613kb microfloppy, analysis available with HP,18284A pod. Full monitor and decoding of major
128kb non-volatile RAM disk. Complete with RS-232C, RS-449 and V35 protocols over any channel. Fractional channel or full CEPT-E1. Complete
interfaces, printer and video outputs. English decodes with customizable displays. Time stamp for captured data
or statistics, 100ns resolution. Extensive data filtering capability. Real
Nettest Fastnet Probe time statistical including LAN traffic analysis over WANS. 100% capture.
GNE,FP1601SR AU
performance during full line loading. Simultaneous decodes statistics,
Fastnet probe for Frame Relay. Provides monitoring and statistical
triggers, and filters. Log to hard drive. Full Bit Error Rate tests to 2mb/s
information for Frame Relay Networks. Complete with interface cable and
(BERT) including G821. Over 150 prewritten tests included.
management software.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 31
DATA, NETWORK & TELECOMMUNICATIONS
LAN Cable Testers
Fluke DTX1200 Category 6 Cable Certification Tester Fluke DTX-MFM Multimode Fibre Adaptor for DTX Cable
FLU,DTX1200 AU/NZ Analyser
Cable certification tester. Tests up to 350MHz; Cat6 Autotest time of 12s. FLU,DTX-MFM AU
Comes complete with latest cat6 PM-06 peronality modules. Linkware PC DTX1200/1800 multimode fibre interface. Tests fibre installations in local
software, and USB cable. Internal memory stores 350 tests. Optional area networks. Fits in the slot on the back of DTX cable analyser (standard
memory card stores 2,000 tests. copper cable adaptors can be connected but not used simultaneously).
Provides fibre testing and certification. Bi-directional testing at 850nm
& 1300nm at the same time. Measures optical power loss, length, and
propagation delay for multimode fibres. Pass/fail results based on common
fibre standards. SC optical connectors. Includes in built visual fault locater.
(VFL)
Fluke DTX-SFM Singlemode Fibre Adapter for DTX Cable
Analyser
FLU,DTX-SFM AU
DTX1200/1800 singlemode fibre interface. Use for testing fibre installations
in local area networks. Fits in the slot on the back of DTX cable analyser
(standard copper cable adaptors can be connected but not used
simultaneously). Provides fibre testing and certification. Bi-directional
testing at 1310 nm and 1550 nm at the same time. Measures optical power
loss, length, and propagation delay for multimode fibres. Pass/fail results
based on common fibre standards. SC optical connectors. Includes in built
Fluke DTX1800 Category 7 Cable Certification Tester visual fault locater. (VFL)
FLU,DTX1800 AU/NZ
Fluke DSP Personality Module for DSP4X00 series
Cable certification tester up to 900MHz; Cat6 Autotest time of 12s. Comes
FLU,DSP-PM AU
complete with latest cat 6 PM-06 personality modules, Linkware PC software,
Personality module for Fluke DSP4X00 cat6 Permanent Link heads. RJ45
and USB cable. Internal memory stores 350 tests. Tests to Cat 3, 4, 5, 5E,
connector sets (PM-01, PM-06, PM-25) include 2 modules. Block connector
6 & 7. Included Cat6 heads will test up to category 6. Optional memory card
sets include one module (PM-12B, PM-13B). Modules available include PM-
stores 2,000 tests.
06 (most systems), PM-25 (most unshielded systems), PM-01 (legacy), PM-
12B Paduit GIGA-PUNCH 110 block, PM-13B Siemon S210 block.
Fluke Networks CableIQ Cable & Network Identification Tool
FLU,CABLEIQ
CableIQ cable and network tester for twisted-pair, coax, and audio cabling.
Allows troubleshooting connectivity problems and qualify cabling bandwidth
to see whether an existing cabling link is qualified to support 10/100, VoIP
or Gigabit Ethernet. Discovers what is at the far end of any network cable.
Detects speed and duplex settings of attached switches and PCs. Intelligent
wiremap graphically shows distance to faults (e.g., pin 1 break at 31m). Can
also test cable set-up for audio application (intercom/PA). Hand held and
lightweight, powered by 4 x AA Alkaline batteries. Can be used as a signal
source for optional Intellitone cable tracer.

>NEW
Fluke DTX 10 Gig copper Testing and Certification Kit
FLU,DTX-10G KIT AU
Used in conjunction with the FLU,DTX1800. Enables testing and certification
of twisted pair cabling for 10 Gigabit Ethernet deployments - whether it is an
existing Cat 6 or newly installed augmented Cat 6 cabling system. Measures
the performance for 10 Gig and Alien Crosstalk (ANEXT and AFEXT) in full
compliance with the industry standards to 500 MHz.

32
DATA, NETWORK & TELECOMMUNICATIONS
Fibre Optics

> NEW
Fiber Video Display Scope
FLU,FT330 AU
> NEW
Fiber Inspection Video Probe X 250 & 400 Magnification
FLU,FT650 AU
Handheld battery operated video scope for fiber inspection. Fibre probe for use with Fluke Optifiber OTDR or FLU,FT330 handheld video
scope. Has switchable 250 and 400 times magnification.

Fluke FTK200 Optical Fibre Power Meter/Light Source


FLU,FTK200 AU
Comprises light source and power meter. Light source is multi-mode 850nm
& 1300nm (-20dBm into 62.5µm fibre). Stability is ±0.1dB per 8h at 250C.
Power meter has calibrated measurements at 850/1300nm multi-mode &
1310/1550nm single-mode. 6dBm~-50dBm measurement power with 0.01
resolution & accuracy of ±0.25 at 250C & -10dBm. Power meter memory
> NEW
Fiber Inspection Video Probe X 250 Magnification
FLU,FT350 AU
stores up to 500 results at each wavelength which can be downloaded to PC
with supplied software (also compatible with Fluke Cable Manager used for
the DSP4000/4100 series). ST connector on power meter and light source.
Connects to a FLU,OPTIFIBER or FLU,FT330 to let you inspect the ends of
fiber optic connectors. 250 X magnification reveals dirt, scratches, and other
defects that can cause poor performance or failures in fiber optic networks.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 33
DATA, NETWORK & TELECOMMUNICATIONS
Fibre Optics
Fluke Optifibre Multi-mode OTDR Nettest 6250/6025 Light Source/Power Meter 1310/1550
FLU,OPTIFIBER-MM AU GNE,6250/6025 AU
Short range multimode OTDR designed for testing, troubleshooting and Single-mode light source (6250) and power meter (6025) combination. Light
certifying network cabling. 850/1,300nm, 62.5mm (100m launch cable source is 1310nm/1550nm, -8 dBm min power output laser output. Power
included) & 50mm (requires launch cable) fibres with SC connectors. meter and light source autoswitch wavelengths to synchronize with each
Attenuation deadzone 850nm: 4.5m typical, 5.5m max 1,300nm: 10.5m other. Stores past 2 results in memory for reference. Comes in hard case.
typical, 15m max. 3km range for 850nm & 7km range for 1,300nm. Measures Battery operated
insertion loss and fibre length, allows automatic and manual OTDR analysis
including channel map of connectors. Included LinkWare PC software
Nettest FI720 Active Fibre Detector
GNE,FI720 AU
documents, reports and manages all test data. Battery operated with colour
Non intrusive fibre tool for identifying active fibres. Measures bare fibres,
display.
coated fibres, and jacketed patch cords. Gives readout of optical power level
in fibre and can detect optical test tones of 270Hz, 1, & 2kHz. Measures
wavelengths 800~1700nm and power levels from 0~-40dBm (±2). Insertion
loss <0.5dB. Note: accuracy of power measurement depends on fibre,
coating, & jacketing. For accurate power measurements an optical power
meter should be used.

> NEW
Nettest CMA 5000 Singlemode 43/45dB OTDR
GNE,CMA5000SM-45 AU
Single mode OTDR with SC/APC (angled) adaptor. 1310/1550/1625 dynamic
range 43/45/43dB. +20dBm meter and light source, and VFL (Visual Fault
Locator). OTDR has built in CD-R/W and 20GB hard drive. Dedicated touch
Acterna OMK-6 Fibre Optic Power Meter screen and hard key user interfaces. Mains and battery operation, battery
WG,OMK-6 AU/NZ life >3h. 10/100MB Ethernet port for network connectivity. USB ports.
OMK-6 optical power meter with multi mode and single mode light sources.
Level measurement is -65~+10dBm. Measurement errors are eliminated
because the power meter automatically detects the wavelength being
transmitted by the light source. Single mode dynamic range with continuous
wave is 58dB (approx 145km @ 1310nm & 230km @ 1550nm). Multi mode
dynamic range with continuous wave is 40dB (approx 20km at 850nm &
50km at 1310nm).
Acterna OMK-14 Optical Measurement Kit
WG,OMK14 MY
Kit consists of WG,OLS-15 (light source) and WG,OLP-15 (power meter).
WG,OLS-15; 1310nm & 1550nm, o/p; 7dBm (into 9/125µm) mod frequency:
270Hz, 1kHz, 2kHz. WG,OLP-15; 800~1700nm, switchable at; 850, 980, Nettest CMA4000 Single/Multi Mode OTDR
1310, 1480 & 1550nm. Sensor type InGaAs, suitable fiber type 9/125a~50/ GNE,CMA4000MMSM AU
125µm. Mod detection; 270Hz, 330Hz, 1KHz, 2KHz. Display range - Includes mainframe and 850/1300nm (25/24dB) multimode and 1310/1550nm
70~11dBm. (30/30dB) single-mode module (module Model 4457). Instrument has built
in FDD and supplied with SC/PC, FC/PC, and ST/PC connectors.
Kingfisher Optical Attenuator
KIN,KI7010 AU/MY Nettest CMA4000 Single/Multi mode OTDR
1310/1550nm single-mode including 2 interchangeable PC connector GNE,CMA4000MM AU
interfaces, and adaptors. Attenuation range 60dB, resolution 0.05, power Single mode and multi mode OTDR. Includes mainframe and 850/1300
capability +20dBm and linearity 0.02dB. Operational modes include manual, nm (25/24 dB) multimode and 1310/1550 (30/30 dB) single mode module
relative, step and programme control. (module Model 4457). This instrument has built in 3.5 disc drive and is
supplied with SC/PC, FC/PC, and ST/PC connectors.
Kingfisher KI 6000/8000 Optical Power Meter and Source
KIN,KI6000/8000 AU Nettest CMA4000 Single Mode OTDR
Light source (KI8000) and power meter (KI6000) optical fibre test set for GNE,CMA4000SM AU
multimode applications 1300nm & 850nm. Units have ST connectors and Includes mainframe and 1310/1550nm (34/36dB) single-mode module
a variety of patch leads. Light source modules 812 & 809 fitted to KI8000. (module part number TD-14M25003 Model 4425). Instrument has built in
KI6000 power meter uses a germanium detector for broadband operation. FDD and supplied with SC/PC, FC/PC, and ST/PC connectors.
Power meter can be used for single-mode applications but requires a
seperate single-mode light source such as the KIN,KI8022.

Nettest CMA4000 1310/1550nm (40dB) Single Mode Module


GNE,TD-14M36003 AU
For the GN Nettest CMA4000 OTDR mainframe. Module has SC/PC &
FC/PC connectors. Operating wavelengths are 1,310nm (40dB) & 1,550nm
(40dB).

34
DATA, NETWORK & TELECOMMUNICATIONS
Fibre Optics

> NEW
Yamasaki Y16 Fibre Cleaver
YAM,Y16 AU
Fitel S121A V-Groove Fusion Splicer
FIT,S121A AU
Splice loss is 0.1dB for single mode & 0.05dB multi mode. Splice time is 13s.
Precision fibre cleaver. This cleaver can be used with precision splicers for Includes splice protector heat shrink heater and splice tension tester (200g).
single and multi mode fibres. Operates from ac (100~240V) or battery (up to 30 splices & heatings per
charge). Cleaver excluded.
> NEW
Yamasaki Y80 Core Alignment Fusion Splicer
YAM,Y80 au
Precision core alignment single and multi mode fusion splicer. Instrument
is fully automatic or manual and provides a typical splice loss of 0.02 dB
on single mode fibre, and 0.01 dB on multi mode fibre. The instrument has
automatic environment sensors, operates from -10C to 50C, 95% humidity
and operates up to 4000m. Includes a built-in heater for applying splice
protectors and a splice tension tester. Front mounted colour display and can
be operated from AC (176-264V, 47-63Hz), or battery.

Fitel S175 Core Alignment Single & Multi Mode Fusion Splicer
FIT,S175 AU
Default multi-mode operation is cladding align. Fully automatic. Provides
typical splice loss of 0.02dB on single-mode & 0.01dB on multi-mode.
Temperature, humidity & altitude sensors adjust arc time & intensity. Includes
built-in heater for applying splice protectors. Cleaver excluded.
Fitel S176CF Core Alignment Single & Multi Mode Fusion
Splicer
FIT,S176 AU
> NEW
Fitel S325A Precision Fibre Cleaver
FIT,S325A AU
Fully automatic. Typical splice loss of 0.02dB on single-mode & 0.01dB on
multi-mode. Splice time 13s. Temperature range -10~500C, humidity range
up to 90%RH at 380C & altitude sensors (operates up to 3,658m) adjust arc
Can be used with precision splicers for single and multi mode fibres.
time & intensity. Includes heater for applying splice protectors and splice
Features a built in sharps collection bin which automatically stores fibre
tension tester (200g). Front mounted colour display. AC mains operation
offcuts as each fibre is cleaved.
100~240V, or battery (up to 60 splices & heat shrinks per charge). Cleaver
excluded.

> NEW
Fitel S177A Core Alignment Fusion Splicer
FIT,S177A AU 300M Multimode Fibre Optic Launch Cable
FIB,MULTI/300M au
Precision core alignment single and multi mode fusion splicer. Fully
automatic and provides a typical splice loss of 0.02dB on single mode and Multimode fibre test cable. 300 metres.
0.01dB on multi mode. Splice time 9sec. Temperature range -10~50ºC, Anritsu MG921A 1300nm Stabilised Light Source
humidity range up to 90% at 38ºC, and altitude sensors operate up to 4000m ANR,MG921A MY
which adjust arc time and intensity as required. Includes a built-in heater for Use with multi-mode/single-mode fibre of 1.3µm wavelengths.
applying splice protectors and a splice tension tester (200g). Front mounted Unprecedented light o/p level & wavelength stability through use of APC
colour display. AC mains operation 100~240V, or battery (up to 70 splices). & temperature control ccts. Internal & external modulation functions are
Excludes cleaver which must be rented separately. provided, permitting removal of stray light.
Nettest TD-4791-CL DWDM Optical Spectrum Analyser Module
GNE,OSA-TD4791CL AU
For dense wavelength division multiplexing applications. Can be used over
optical fibre C (1,530nm~1,570nm) & L bands (1,570nm~1,628nm). Use
with CMA-4000 mainframe. Resolution to 10GHz. For all WDM applications
including high density of 80 channels and above.
Nettest Nexus Polarisation Mode Dispersion Analyser
GNE,PMD AU
For optical C-band measurements. 55dB dynamic range. For measurements
on optical fibre for qualification for DWDM or analogue video applications.
Noyes OFS300 Fibre Optic Cable Microscope
Fitel S323B Fibre Cleaver NOT,OFS300 AU
FIT,S323B AUNZ
Use with precision splicers for single and multi mode fibres. Built in sharps
collection bin automatically stores fibre offcuts as each fibre is cleaved.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 35
CABLE/PIPE TESTERS & LOCATORS
Cable/Pipe Testers & Locators

> NEW
Fluke IntelliTone Pro 200 Kit
FLU,INTELLITONEPRO AU
HDW T19 15 kV Surge Generator
HDW,T19
Cable fault location system. For use with HAG,2000 time domain
AU

Locate, isolate, and validate twisted pair (UTP, Cat 5e, Cat 6), coax cables reflectometer, can be used as a stand alone instrument as a “thumper” and
(RG6, RG59, and others for CATV/CCTV), bare wire (such as speaker wire insulation tester. Comprises a high voltage generator with an arc reflection
and security network wire), and Cat 3 telephone cabling. The toner also lets filter. Surge output range to 15kV. High voltage insulation test output to
you validate voice and data services. 40kV dc. Leakage current ranges 10µA~100mA. Use to burn faults up to
25mA continuous output. Thumper function provides 800j of energy up to
15kV up to 5s.
Radiodetection Stethoscope Antenna for RAD,RD400 Series
RAD,STETH-L AU
Concave head fitted to flexible goose neck with handle. Length 480mm, head
46mmØ. Frequency range 50Hz~65kHz. Connect to any Radiodetection
receiver fitted with accessory socket.
Radiodetection RD500 Plastic Pipe Locator
RAD,RD500 AU
Operates with 3 alternative pressure wave signal transmitters. Range 150m.
Location accuracy to 25% of depth to 2m. Transmitters included to match
meter base, hydrant, and tap outlets.
Megger TDR1000
MEG,TDR1000 AU
For cable consisting of 2 insulated metallic elements, one of which may be
the armouring or screen of the cable. Internal matching networks to allow
Tempo TE-508S Cable Locator testing of 25, 50, 75 & 100 cables. Can be matched to the cable using the
TEM,508S AU/NZ
balance control allowing long lengths of cable to be easily tested and faults
Tempo 508S Cable Locator for locating buried or in-wall wiring. Compact
close the instrument to be seen. Propagation velocity value can be similarly
design. Provides results on buried cables to depths of 1 meter and lengths
adjusted to match the cable, ensuring an accurate distance measurement can
up to 300 meters. Can be used to determine approximate depth of a wire or
be directly read. Gain of the instrument is also variable, allowing more minor
cable before you dig. Fully adjustable transmitter output and receiver gain
faults to be identified over length of the cable. Eliminates the transmission
Transmitter frequency is 447.5KHz. Transmitter can be connected directly to
pulse ‘dead zone’. Range 10m~3km. Display: Large high-resolution backlit
AC power outlet. Transmitter runs approximately 35 hrs and receiver runs
[LCD]. Batteries 6 x LR6 (AA), alkaline, NiCd or NiMH cells. Consumption
approximately 20 hrs from standard 9V batteries.
100mA nominal 140mA with backlight (20/30h continuous use depending on
backlight use). Dust and shower proof to IP54.
Megger TDR2000 TDR Cable Fault Locator
MEG,TDR2000 NZ
Minimum resolution of 0.1m and a maximum range of 20km at 0.9VF and
16km at 0.65VF. Perform single or dual channel measurements on a wide
range of metallic cables. Active channels can be compared with each
other or with previously stored traces from memory. Differential channel
measurements are possible and cross talk between channels can also be
identified.
Megger TDR20002RM Dual Channel TDR
MEG,TDR2000/2RM AU
Range 20km at VF =0.90. Monochrome display with backlight, dual cursor
measurement, output pulse amplitude and width control. No blocking filter
required for direct connection to live systems up to 300Vac. 15 memory
trace storage, down loadable to PC via RS232C interface, software
Pathfinder PF610 Circuit Tracer Kit supplied. Ranges 50m, 100m, 200m, 400m, 1km, 2km, 4km, 8 km &
PAT,PF610 AU
16km. Resolution 0.1m up to 200m, 0.2m up to 400m, 0.1% of range above
For tracing concealed power cabling and other signal or data conductors.
400 m. Measurement accuracy 0.1% of range. Input impedance 120Ω.
Comprises a transmitter and a detector. Transmitter when connected to a
Velocity factor variable from 0.300~0.999 in steps of 0.001. Powered via
cable generates a 4.6kHz current pulse by drawing low current from the
rechargeable NiMH powerpack, charger supplied.
cable circuit. In the case of data and signal circuits a 9V battery can be used
to power the cable. This may require disconnection of computer equipment, Dynatel 2273 Buried Cable and Fault Locator
etc. Detector gives audible and visual indication of the signal field. Trace 1 DYN,2273 NZ
& 3 phase cables, coax, buried unpowered cable, locate fuses, etc. Features include ac V meter, Ω meter, cable depth meter (non energised
cables only) and multiple frequency transmitter (user selectable). Trace path
Pathfinder 220 Cable Locator/Tracer of energised and unenergised cables, indicate cable depth and locate the
PAT,LOCAT220 AU
position of shorted conductors to ground using the A frame accessory. Max
For tracing live power cables within buildings. Connection is generally made
depth is 2.5m.
at an outlet. Transmitter has visual and audible indication. Range 3m.
3M Scotchtrak Cable Locator
Haganuk Teleflex 2000 Cable Fault Tester SCO,TK-6B NZ
HAG,2000 AU
Short circuit cable and circuit breaker tracer. Traces wires in walls, floors
Time domain reflectometer for power cables. Measuring ranges : 250, 500,
and ceilings back to the switchboard. Locates associated fuses and circuit
1,000, 2,500, 5,000, 10,000, 25,000 & 50,000ft. Pulse widths: 10, 100, 200,
breakers. To be used on live circuits.
1,000, 2,000 & 10,000ns. Accuracy: ±1% typical, <2% worst case. Digital
display of distance. Can only work with multi-core cable with respect to
between the cores or with respect to core and shield. Not suitable for finding
faults to ground or between 2 separate cables.

36
CABLE/PIPE TESTERS & LOCATORS
Cable/Pipe Testers & Locators
Tektronix 1503C TDR Cable Tester Radiodetection RD400PXL Pipe and Cable Locator
TEK,1503C AU/NZ/MY RAD,RD400PXL AU
Distance range 50,000’, resolution 0.04’ & 50, 75, 93, 125Ω output Can measure current in buried lines. Includes transmitter and locator, peak
impedance. LCD display. Internal battery or mains operation. Supplied with and null location by audio and meter, very useful in congested areas. Has
ethernet testing and isolation network options. power /radio/8kHz/33kHz modes, can read depth to 3m. Includes direct
connect lead and signal clamp (tong) (10cm). Works with optional sondes to
trace sewers and plastic pipes.

> NEW
CScope CATXDSGV-KIT Cable and Pipe Locator
CSC,CATXDSGV-KIT AU/NZ
Cable location tool. Includes 33kHz generator with touch button controls
and LCD, XD receiver/ locator with 33kHz, power or radio modes. Direct
connection cable, stake and 75mm tong set. The transmitter can operate
with direct connection, tongs or induction. The instrument will also determine
cable depth, range 0.2m to 3m . It will operate with the Radiodetection
Tektronix 1503 Time Domain Reflectometer 33kHz sondes.
TEK,1503 MY
Time Domain Reflectometer for long cable fault location. Display from
0~5,000 to 0~50,000 feet. Internal battery or mains operation.
Tasco PTR600 Cable Tracer
TAS,PTR600 NZ
Clamp-on earth tester 0.01~300Ω. Measures earth resistance by using 2
clamp CTs without disconnecting the earth conductor. Measures the dc loop
resistance without any influence from other conductors.
Radiodetection RD4000 Type 7 Cable Location Kit
RAD,RD4000TYPE7KIT AU
Includes transmitter and locator. Receiver has 640Hz, 8, 33 & 82kHz, 2
power and radio modes. 3 locating modes. Modes, 2 peak, 1 null, location
arrows, simultaneous digital depth and current readout. Transmitter T10
version, FF, 640Hz, 8, 33 & 82kHz transmission freq. LCD display for freq, ICC LD400 Ultrasound Leak and Emission Detector
power, battery and connection readout, multimeter function, cable fault ICC,LD400 AU
find function, 10W output, high efficiency induction mode. Signal clamp Used to detect water and gas leaks, from ultrasonic emission. Also used for
100mmØ. Connection leads and carry bag. mechanical noise location. Supplied complete with an ultrasonic transmitter
to enable leaks within containers to be detected, e.g. vehicle bodies, fuel
tanks. Aural and visual indication. Battery operated.
ICC LD408 Noise Leak Detector
ICC,LD408 MY
Used to detect water & gas leaks, etc. from ultrasonic emission. Also may
be used for mechanical noise location. Supplied complete with an ultrasonic
transmitter to enable leaks within containers to be detected, e.g. vehicle
bodies, fuel tanks. Aural & visual indication. Battery operated.
Ultra Probe UP100KT Ultrasonic Leakage Detector
ULT,UP100KT AU/NZ
Hand held pistol type with stainless steel sensor enclosure. Frequency
reponse 20~100kHz, (centred at 28 ~42kHz), 10 segment LED bargraph
(red). Sensitivity 8 precision attenuation. Response time 300ms, operating
temperature range 0~500C. Kit includes contact stethoscope module with
different wave guide extension rods for direct for use on pipes, bearing
Radiodetection A Frame for RAD,RD4000 Type 7 Kit housings, steam traps, etc. Rubber focusing probes, head set, warble tone
RAD,AFRAME FORRD4000 AU
generator for determining leaks in seals of empty containers, etc.
A-Frame accessory for RAD,RD4000Type7KIT. For sheath to ground type
fault finding.
Radiodetection Flexisonde Pipe Tracer
RAD,FLEXISONDE AU
Sonde for use with RD400PXL. Flexible rod on reel 50m long complete
with 2 sondes. Small sonde transmitter is suitable for insertion into plastic
pipes of 25mmØ & 150mm min bend radius. Can be detected at depths
up to 1.5m. Larger sonde can be detected at 5m depth and is suitable for
insertion into plastic pipes of 80mmØ & 210mm min bend radius. Sondes
are battery operated.
Radiodetection Supersonde
RAD,SUPERSONDE AU
Primayer Omikron Water Leak Detector
Can be connected to the RAD,FLEXISONDE cable if required. Detectable
PRI,OMIKRON-AG AU
to 15m depth.
Water leak locating listening probe and ground microphone system designed
Radiodetection 100mm Clamp Antenna to locate leaks in water pipe. Supplied with headphones and interconnection
RAD,CLAMP-ANT AU cables. Probe detects leak noise directly at available valves hydrants, etc.
For use with RAD,RD400PXL. Identify an individual cable out of a bunch. High sensitivity and wide band amplification of leak noise particularly at lower
Good for cable tracing. Transmitter is connected to one end and placed frequencies. Microphone will detect noise reaching the ground surface.
around individual cables for identification. Clamp is 100mmØ.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 37
electrical power
electrical POWER
Magnetic Field Meters - Gauss Tesla
Model Type Frequency (Hz) Range (G) Electric Field Output
ARL,GM AC magnetic field meter 12~1,300 9.9 ~ 99mG CRO

HOL,HI-3627 Vector AC magnetic field meter 5~2,000 0.2 ~ 20

HOL, HI-3604 AC field strength meter 50~100 0.1 ~ 20,000mG 1~200,000V/meter


TES,70 AC magnetic field meter 30~600 0.1 ~ 1,999mG

HMI,GM04 dc~10kHz 30 ~ 30,000

BEL,4048 dc~12 200 ~ 20,000

BEL,4080 Digital gauss meter 40~600 0.1mG ~ 511mG

BEL,5080 dc~20kHz 300 ~ 30,000 Analog & RS232

BEL,5180 dc~20kHz 300 ~ 30,000 Analog & USB Port

BEL,4090-20 Digital ELF gauss meter 40~400 0.1 ~ 1999mG

> NEW
Bell 5180 Gauss/Tesla Meter
BEL,5180 au
Holaday HI-3627 Magnetic Field Meter
HOL,HI-3627
Three orthogonal field sensors. Dynamic range 0.2mG~20G. True rms
AU

Magnetic measuring equipment, portable gaussmeter. Built-in software detection. Frequency range 5Hz~2kHz with an in-built 30Hz high pass filter.
eliminates the need for complex calibration procedures. Key features Meets requirements of the Swedish protocol and the IEEE P-1140 protocol.
include Auto Zero, Min./Max./Peak Hold, Auto Range and Relative Mode.
Holaday HI-3604 LF E & H Field Monitor
Allows the user to select Gauss, Tesla or Ampere/Meter readings. With
HOL,HI-3604 AU/MY
Hall effect transverse probe. Frequency bandwidth DC~30kHz, range up to
Low frequency field meter. Designed to evaluate electric and magnetic fields
30kG. Analogue output (±3V FS) and USB interface. Battery operated.
associated with 50Hz power lines. Frequency range 30~2,000Hz. Measures
magnetic fields from 0.1 milligauss to 20 gauss. Measures electric fields from
1 volt/meter to 200 kilovolts/meter. LCD display. 127 reading data memory.
Meets the interim requirements of the Australian Radiation Laboratory for
normal levels of AC power exposure.
Hirst GM04 Microprocessor Controlled Gaussmeter
HMI,GM04 AU
Facilities: store and recall on 0~99 samples, hold. Analogue peak with
digital storage. Auto and manual ranges. Automatic reading conversion
between different units. (Note 1mT = 10G)
Range 1: 0~to more than 3T resolution 1mT.
Range 2: 0~299.9mT resolution 100µT.
Range 3: 0~29.99mT resolution 10µT.
Range 4: 0~2.999mT resolution 2µT.
Accuracy (at 200C): ± 1%. Frequency range: dc and 15Hz~10kHz.
Functions: dc, dc peak, ac rms, ac rms max, & ac peak. Applications include
Arlyuna LF Milligauss Magnetic Field Strength Meter measurement of magnetic flux density of magnets and assemblies, electric
ARL,GM NZ
motor air gaps and drive actuators.
Handheld ac magnetic field strength meter. Ranges 9.9mG & 99mG.
Measurement bandwidth 12Hz~1.3KHz. 60Hz & 50Hz filter and analogue Hirst Magnetic Instruments GM04 Axial Probe
ac output for connection to oscilloscopes, recorders or loggers. HMI,GMO4AXIAL PROBE AU
Axial probe for use with HMI,GM04.
Bell 4048 ac/dc Gauss Meter
BEL,4048 NZ Teslatronics 70 milliGauss Meter
Handheld digital ac/dc Gauss/Tesla meter. Ranges are 200~20kGauss with TES,70 NZ
a resolution of 0.1Gauss or 0.02~2Tesla with a resolution of 10E-6Tesla. Tri-axial ac magnetic field meter. Range is 0.1~1,999mGauss, accuracy is
Accuracy is 2% +2 digits. Peak hold feature. Supplied with transverse probe ±1% at 60Hz. Frequency response is 40~400Hz ±10%, 50~300Hz ±5%,
and zero gauss chamber. 30~600Hz - 3db.
Bell 4080 ELF Gaussmeter Tri-axial Milligauss Magnetic Field Meter
BEL,4080 AU BEL,4090-20 NZ
Handheld digital ELF gaussmeter. Resolution 0.1mG. Auto ranging Handheld digital ELF gaussmeter. Resolution 0.1mG. Auto ranging,
0.1~511mG. Probe: 3 axis technology, maintains accuracy regardless of 0.1~1999mG. Resolution 0.1mG in high-sensitivity mode & 1mG resolution
orientation. True rms measurement. Typical accuracy error: ±2%, +1 digit. in low-sensitivity mode. Probe 3 axis technology, maintains accuracy
Frequency response: ±5% 40~600Hz, -3dB 25/1,000Hz. Applications regardless of orientation. True rms measurement. Typical accuracy error:
include detecting magnetic field emissions from overhead ac power lines, ±1% + 1 digit. Frequency response: ±10% 40~400Hz, -3dB, 20/2000Hz.
video display terminals, office equipment and household appliances. This Applications include detecting magnetic field emissions from overhead
unit is not suitable for measuring field strength of “neodymium” or “rare earth” ac power lines, video display terminals, office equipment and household
magnets or any permanent magnets. The frequency response ± 5% 40- appliances.
600Hz and -3dB 25/1000Hz.
Bell 5080 Gauss/Tesla Meter
BEL,5080 AU
Portable gaussmeter complete with Hall effect transverse probe. Frequency
bandwidth dc - 20kHz, ranges 300G~30kG. Max resolution 0.1G (10µT). Max
and min hold. Analogue output and RS232 interface. Battery operated.

40
electrical POWER
Insulation/Condition/Resistance Testers
Voltage Resistance Current Frequency
Model Type Features
V Ω A Hz
AS3760:2001 Compliant, full
keyboard, barcode scanner,
SEW,X3760PKIT+
RS232, Automatic label/tag
Portable Appliance Tester printer
AS3760:2001 Compliant, barcode
SEW,EUROPA PAT
scanner, RS232
MEG,CBT2 RCD Tester 6~500mA

MEG,LT6 Earth Loop Impedance 20~2kΩ

LEM,SATURN GEO
0~20kΩ 50mA 128 Battery,RS232
EASY
48ac
Soil Resistivity Tester Battery, Stakeless measurement,
LEM,SATURN GEO X 1mΩ~300kΩ 250mA 94~128
earth loop impedance,RS232

MEG,DET5/3R 0.1~19,999 128 Battery


MEG,DET20C Earth Resistance Clamp 25mΩ~1550Ω 0.2~35 Battery, USB output of data
MEG,BM21 25~5000 5TΩ 2mA/kV
500,1kV, 2.5kV, Battery
MEG,BM11D 10kΩ~500GΩ
5kV
Operates from main supply or
MEG,10-01-10KV 10kV 1TΩ 99µA
rechargeable battery
Operates from main supply or
MEG,1020-10KV DIT 50~5000 35TΩ
battery
Insulation Tester dc
LEM,SATURNISO 50 ~ 1,000 30GΩ Battery

250, 500, 1kV, Battery, data storage & USB


HIO,3455HVIT,5KV 5TΩ 1mA
2.5kV, 5kVdc interface

Insulation with 200mA continuity


HIO,3454-51-3 250, 500, 1000 4GΩ 200mA
tester

Four in one HV test set


HVD,HVA30-DC/VLF High Voltage Insulation 33kV, 5µF 190hm 15mA VLF/DC/Jacket Sheath/Fault
dc/VLF Conditioning
DielectricsTest Set
HVD,HVA60-DC/VLF 60kV, 50mA
CHK,LM05 1µΩ~20Ω 10 Battery
CRO,D07 600µΩ~60Ω 10 c/w Probe/Lead Set
T&R,DSM600 67µΩ~6.6mΩ 600
RS232
T&R,DSM200 200µΩ~4Ω 200/10
VAL,4300B 2µΩ~20kΩ 100mA~10 Heavy duty Kelvin leads
Micro-Ohm Meter dc
MEG,DLRO10 Alpha-numeric keypad for
0.1mΩ~2kΩ 10 entering test notes, autoranging
MEG,DLRO1-10X
with manual option, realtime or
from storage via RS232, large
MEG,DLRO200 10~200
0.1µΩ~999.9mΩ backlit LCD
MEG,DLRO600 10~600 RS232, Software
MEG,CM500 0~250mA 16~460 RS232, Software, RCD tester,
Multifunction Installation 0.01~499MΩ Loop impedance, Prospective
MEG,MFT1502 280~1kV 0~200mA 45~65
Tester short circuit
LEM,SATURN100+ 1~400 0.01~9.99kΩ 0~1 15.3~457 Battery
BAU,DPA75 0~ 75kV rms RS232
Oil Insulation Tester
AVO,OTS60PB 60kV rms Battery, RS232
BJM,ALL-TEST3 Motor, Coil Tester 1 kV 0~20MΩ 100~2,400 Power Factor, Capacitance
3M,701 Megohm Meter 10 ~ 100 0~10GΩ ESD Surface Testing
MEG,MIT1020-10KV DIT Insulation Resistance 1kV~10kV 10kΩ~35TΩ USB, RS232, Battery
MEG,RCDT330 Residual Current Device 0~300 10mA~1kmA 25~450 USB, Battery, IP54
See Also Hi-Pot Testers

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 41
electrical POWER
Insulation/Condition/Resistance Testers

> NEW Megger MIT1020 Diagnostic 10kV Insulation


Resistance Tester
MEG,MIT1020-10KV DIT AU
> NEW HV Diagnostics 60kV-50mA DC/VLF High Voltage
Insulation Dielectrics Test Set
HVD,HVA60-DC/VLF AU
Backlit display, variable test voltage from 50~5000V, Automatic IR, PI, DAR, True sine wave low frequency output. 0.1Hz & 0.02HZ. For VLF, DC and
SV and DD tests, measures to 35TΩ, RS232 & USB download of results. jacket/sheath testing. Fault conditioning capability. Test result storage
IEEE 43-2000 recommends the use of 10kV for motor windings rated above capability. Short circuit protection. Complies with CENELEC, IEEE 400.2,
12kV. Protection rating of IP54. Mains or battery powered. VDE 0296 and other international standards. Manual or fully automatic test
sequence selection. Real-time display of actual output waveform. High
voltage power source suitable for testing electrical plant including cables:
XLPE, PE, EPR, PILC etc, capacitors, switchgear, transformers, rotating
machines, insulators and bushings.

Megger 10-01 10kV Insulation Tester, Test Voltage 500~10,000V


MEG,10-01-10KV AU
The Megger MEG,10-01-10kV Insulation Tester is a compact, Microprocessor
controlled high voltage dc Insulation tester. Hioki 3455 High Voltage Insulation Tester
HIO,3455HVIT-5KV AU
PI and DAR function to check insulation quality and step voltage test to detect
for signs of deterioration. Generates a wide range of test voltages, from
250V to 5kV. The voltage may be chosen from the commonly used presets
of 250V, 500V, 1kV, 2.5kV & 5kV, or set to desired level by increments or
decrements of 25V or 100V. Insulation diagnoses for automatic calculation
and indication of PI (Polarisation index) and DAR (Dielectric absorption ratio),
step voltage testing and temperature correction. Large memory stores up to
100 manual records and a logging function for 10 data (360 times). Stored
data may be displayed on the LCD or down-loaded to a PC. The date and
time of measurement also recorded.

> NEW HV Diagnostics 30kV-15mA DC/VLF High Voltage


Insulation DielectricsTest Set
HVD,HVA30-DC/VLF AU/NZ
VLF (0.1Hz), DC (±), cable fault conditioning (Burning), and sheath/jacket
testing modes all included. 0.1Hz & 0.02Hz. For solid dielectric cables
such as XLPE and EPR. Fully automatic or manual cable test sequences
complying with International Standards/Guides such as IEEE 400.2, VDE
0296, CENELEC, etc. True symmetrical sinusoidal, load independent,
output waveform across the full load range. Real-time display of actual
output waveform. Easy to use, menu guided, large backlit user interface.
Large output load capability (up to 5µF). Automatic and integrated load
capacitance measurement with optimum frequency selection. Storage of test
results for later retrieval or download to laptop. Short circuited protected. CHK LM05 Micro-Ohm Meter 10A
CHK,LM05 AU/MY
Operates from internal batteries or external power supply. Max test current
10A. Resistance range up to 20Ω with a max sensitivity of 1µΩ. Includes
power supply-charger, duplex helical test leads, length 2m.
Megger DLRO10 Micro-Ohm Meter
MEG,DLRO10 AU
Self contained automatic micro-ohm meter, selecting the most suitable test
current, up to 10A dc to measure resistance from 0.1mΩ~2kΩ on one of
seven ranges. Instrument is built into a strong, lightweight case that is
equally at home in the field or in the laboratory. Light enough to be worn
around the neck, small enough to be taken into areas which were previously
too small to access. DLRO10 uses a large, bright 4½ digit LED display.
Resolution: 0.1µΩ. Battery: rechargeable NiMH, typical life 1,000 test at
full load.

42
electrical POWER
Insulation/Condition/Resistance Testers
Hioki Digital MΩ HiTester Insulation Tester Megger DLRO-10X Digital Low Resistance Ohmmeter
HIO,3454-51-3 AU MEG,DLRO-10X AU/NZ
Continuity function with 200mA and 3 range voltage selectable 250V, 500V Automatically selects the most suitable test current, (up to 10Adc) to
& 1kV. Easy to read digital display, auto-discharge, live-wire warning, safety measure resistance from 0.1µΩ~2kΩ on 1 of 7 ranges. Real-time download
system for high voltage measurement, sliding cover. Back-lighting liquid of results and on-board storage for later download to a PC. Automatically
crystal display for easy reading in dark areas, checks ground wire continuity detects continuity in potential and current connections. Visible warning of
with a short circuit current of 200mA. Capable of testing the continuity of high voltages present at the terminals. Visible warning of current flowing in
electrical facility grounds in accordance with IEC 60364. Measurement the test sample. Multiple operating modes including fully automatic. Alpha-
range insulation resistance maximum 4000MΩ @ 1kV. Other functions:- numeric keypad for entering test notes. User selectable high and low limits.
insulation and low resistance mode - comparator, measurement value hod, Autoranging with manual option.
insulation resistance mode - auto discharge, insulation and ac voltage mode -
live wire warning (when voltage of 70V+ or -10V exists across measurement
terminals). Low resistance mode - zero adjust. All measurement modes -
battery indicators, auto power off. Maximum rated working voltage 600Vac.

Megger DLRO600 Digital Micro-Ohm Meter- High current


MEG,DLRO600 AU
Measures resistance between 0.1µΩ & 1Ω at high currents. Provides
test currents from 10A~600A subject to the load resistance and supply
RCD Isolation Test Transformer for Testing Portable RCD Unit voltage. Backlit liquid crystal display shows information needed to perform
PRO,ITX125VA-RCD AU a test; all test parameters and measurement results are displayed. Range:
RCD Isolation Test Transformer for Testing Portable RCD units. Input 240V 0.1µΩ~999.9mW [subject to supply voltage and load resistance]. Accuracy:
50Hz and output 230V 125VA thermally protected isolation transformer. voltage ±0.5%, ±0.1mV, current ±0.5%, ±0.1A. Resistance: better than
This is only suitable for testing portable RCDs and by using this isolation µΩ~100mW. Power supply for full output: 207~265V 50/60Hz with a load
transformer will avoid tripping of the whole circuit. It comes with 15Amps less than 7mΩ including current leads [i.e. standard 5m 50mm² current leads
Australian / New Zealand Socket. Isolation test transformer can be used to only, 4mΩ load]. Reduced output: down to 100V 50/60Hz. Test current
test up to 150mA trip current range 10A~600A unsmoothed dc in 1A steps, accuracy ±2%, ±2A. Test
Modes manual, auto, continuous. Test Time 7s NORMAL /AUTO mode.
Cropico DO7 Micro-Ohm Meter complete with Probe/lead Set Refreshed every 2s in CONTINUOUS mode. Voltmeter input impedance
CRO,DO7 AU >200kW. Data Transfer real time or batch download via RS232 using AVO
Low resistance measurement for use in workshop, field or test facilities. Download Manager. Storage Capacity 300 result sets and memo, battery
Rugged construction, in a sealed plastic case with lid and carry handle. backed for 10y.
Advanced features including protection up to 415V rms at the measuring
terminals, digital calibration and long scale length, 6,000 count. Rechargeable Megger 200A Micro-Ohm DLRO200
batteries >1h of continuous operation on lowest ranges, & 20h on all others. MEG,DLRO200 AU
Battery charge indicators are provided. Internal charger will boost charge Digital low resistance micro-ohm meter 200A.
to 90% of full charge, switching automatically to a maintenance charge.
Warning LEDs illuminate when an open circuit lead condition is detected.
RS-232 output for connection to an external printer or PC. Plug is provided
for the connection of external start switch, eg. foot switch. Supplied with
batteries, mains cord and test leads. For special lead sets we offer a variety
of different styles, together with calibration standards.

T&R DSM200 200A Micro-Ohm Meter


T&R,DSM200 AU
Max 200A. Max resolution 0.1µΩ. Digital display with RS232 output. AC
mains operation. Complete with 3m leads.
T&R DSM200 600A Micro-Ohm Meter
T&R,DSM600 AU
Max output 600A max resolution 0.1µΩ. Digital display with RS232 output.
AC mains operation. Complete with 3m leads.
Valhalla 4300B Digital Micro-Ohm Meter
VAL,4300B AU
Selectable current ranges 100µA~10A. Suitable for large electrical
machinery. Resistance ranges 2mΩ~20KΩ with a max resolution of 0.1µΩ.
Basic accuracy 0.03% with a 4½ digit display. Supplied with heavy duty
Kelvin leads.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 43
electrical POWER
Insulation/Condition/Resistance Testers
Megger BM21 500V/1/2/5kV Insulation Test Set Megger CBT2 Earth Leakage Breaker Tester
MEG,BM21 AU MEG,CBT2 AU
Test voltages 25~5,000V in 25V steps. Insulation range to 1TΩ at 500V, Residual current device (RCD)/safety switch, circuit breaker tester. Twelve
5TΩ at 5kV. AC/dc voltage measurement 50V~1kV. Leakage current ranges from 6~500mA. Displays tripping time in ms.
measurement. Capacitance measurement at end of test. Automatic
Metrel MI 2121 AUS Advanced RCD Tester
discharge of capacitance. In-built test timer. Insulation burn mode - short
MET,MI2121AUS AU
circuit current 1mA nominal. Battery life 8h, in-built charger for charging
Exceeds all requirements of AS/NZS3760:2003. Stores up to 500 tests.
from mains or 12V dc.
Interface RS232 Software.
AVO/Megger BM11D Analogue/Digital 5kV Insulation Tester
MEG,BM11D AU/MY
Test voltages 500V, 1kV, 2.5kV and 5kV. Insulation range 10kΩ~500GΩ
digital. AC/dc voltage measurement 50V~1kV. Timer 0~60min. Automatic
discharge of capacitance. Battery life 8h, in-built charger for charging from
mains or 12V dc.
Megger BM25 Insulation Tester
MEG,BM25 AU/NZ
Five kV insulation tester which is battery-powered, housed in a rugged case
and has a large, analogue/digital LCD. A built-in timer makes both spot
tests and Polarisation Index (PI) testing easier to carry out. Pre-set standard
test voltages at 500V, 1, 2.5 & 5kV with variable test voltage in 25V steps.
Megger BT51 Low Resistance Ohmmeter
Displays capacitance at the end of a test to 10µF. Performs automatic PI,
MEG,BT51 AU
Step Voltage and Dielectric Discharge tests as well as providing an optically
Uses 4 terminal method with helical duplex dual pronged probes. Test
isolated RS232 port for downloading results during a test. Short circuit
current 2A nominal at 2Ω. Ranges 2, resolution 1mΩ, 20mΩ, resolution
current: nominal 1.8mA, max 2mA. Battery life: typically 8h.
10µΩ. Accuracy at 0~500C, ±1% of reading, ±2digits. Display LED 3½
digit. Power supply internal NiCd rechargeable batteries, typically around
2,000 tests at 5s duration. Re-charge time around 10h with 240Vac mains
power. Nett weight 45kgs.
Megger LT6 Digital Loop Tester
MEG,LT6 AU
Earth fault loop impedance tester 20Ω range 0.01Ω resolution, 2kΩ range
1Ω resolution. Single & 3ph systems can be tested. Used with MEG,CBT2
to test compliance to AS2381.1 (electrical wiring for hazardous areas).
Tests automatically when connection to circuit is made. Neons indicate fault
conditions.
Megger MFT1502 Combined Insulation, Loop & RCD Tester
Megger CM500 Multifunction Installation Tester MEG,MFT1502 AU
MEG,CM500 AU/NZ
Tests fixed wiring in accordance with International and National Wiring
Combines the function of several instruments. Non-tripping loop test for
Standards. Display digital/analogue arc LCD. Voltage measurement
tests on RCD protected circuits. RCD ramp test features actual tripping
automatic selection ac or dc up to 270V. Continuity testing 200mA from
current. Functions are insulation, continuity, loop testing, RCD tests, voltage
0.01~99.9Ω, automatic continuity testing commences the moment the test
& frequency measurement. Phase indication, outlet polarity indication.
probes touch the circuit to be tested. Audible tone to confirm test. Safety
Stores approximately 750 test results in memory for uploading to PC.
check for presence of a voltage. Variable buzzer threshold selectable from

> NEW
Megger RCDT330 Residual Current Device Tester
MEG,RCDT330 AU
2~100Ω in 6 steps. Insulation testing 250, 500V & 1kV. Safety lockout
at voltages greater than 55V. Auto discharge facility safely discharges all
circuits after insulation test. Low current loop test, a 3-wire non-tripping
Tests standard, dc, selection and programmable RCDs. Ramp testing. Auto 0.01Ω loop test designed to prevent RCD tripping. High current loop test
(remote) testing. 3ph safe. Enables testing on 110V centre tapped supplied. at 25A provides a fast test where no RCD is fitted. Supply voltage and
Performs 1/21, 1xI & 50xI tests on RCDs rated at 10mA, 30mA, 100mA, polarity indication at 55V~280V, 45Hz~65Hz phase to phase. Phase~phase,
300mA, 500mA & 1000mA on general and selective (time delayed) RCDs. phase~neutral and phase~earth loop tests are possible. Loop measurements
Tough rubber armoured case with built-in cover. Weatherproof to IP54. USB from 55V~480V. Prospective short~circuit current (PSC), a high current loop
interface for downloading test result. test, is provided for rapid measurement of loop currents, both at the socket
outlet and distribution board. Ranges from 1A~19.9kA with a resolution of 1,
10 & 100A depending on range auto-ranging. RCD testing 10mA~1000mA
with both 0 & 180O phase angle. RCD ramp test measures the RCD trip
current. Displays actual trip current on all RCD ranges instead of trip time.
LED torch in illuminated probe for low light level areas. IP54

LEM Saturn Insulation Tester


LEM,SATURNISO AU
Test voltages 50~1,000V in steps of 10V. Max range 30GΩ. Measures
ac/dc voltage to 600V, resistance to 30kΩ. Digital and analogue display.
Battery operated.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 45
electrical POWER
Insulation/Condition/Resistance Testers
Kikisui TOS-5051 5kV ac/dc Hi-Pot Tester BJM All-Test IV PRO 2000
KIK,TOS-5051 AU BJM,ALL-TEST-4 AU
High voltage ac/dc insulation test set. Ranges 0~2.5kV & 0~5kV. Max Tests single or polyphase ac motors, generators, transformers or dc motors.
output ac 100mA, dc 10mA. Pass/fail comparator included. Use to test any motor, coil or winding to determine insulation condition
between windings, windings and frame, open circuits. Measure phase
balance and angle. Impedance (z) 5Ω~1kΩ. Inductance (L) 0.35mH~1.6H.
Capacitance (C) 100mF~50nF. Power factor (Fi) 0-90O. Insulation: 0~20MΩ
@ 1kV. Frequency range 100, 300, 850Hz & 2.4kHz (times 2).

> NEW
Megger Digital Earth Test Clamp
MEG,DET20C AU
Measures ground resistance from 25mΩ~1550Ω . Measures ground
leakage current from 0.2mA~35A. Automatic self calibration. Auto ranging.
High and low alarms. Large memory. Download to Megger Download
LEM Saturn GEO Easy Earth Tester
Manager. Measures earth resistance in installations such as buildings,
LEM,SATURN GEO EASY AU
pylons and RF transmitter sites. Use for the inspection and verification of
Waterproof instrument (rubber protective cover IP56). Measures earth
lightning protection systems. Large jaw opening.
resistance, 3 or 4 pole. Soil resistivity. Measures resistance from 0~20kΩ.
Display 4 digit back light 25mm LCD. Operating frequency 128Hz. Single
button user interface. Complete with earth testing kit including 4 stakes, 3
reeled cables, clips and carry case.
LEM Saturn GEO X Earth/Soil Resistance Tester
LEM,SATURN-GEO-X AU
Automatically tests earth/soil resistance 3, 4 pole and stakeless with CT.
Optimise output frequency (manual or automatic) 0.001~300kΩ at 20 &
48Vac, frequency 94, 205, 111, & 128Hz. Displays all measuring results
for as long as desired. Programmable limits. Optical and audible over-limit
warning. Splash-proof case IP56 (outdoor application). Measurements with
current clamps: selective, stakeless. Resistance measurements with 250mA
short circuit current. Output of measured values via interface on printer or
PC.
LEM Saturn 100plus Safety Tester
Megger Det5/3R Ground Resistance Tester LEM,SATURN100+ AU
MEG,DET5/3R AU Confirms correct operation of RCD protection, resistance of all aspects of
MEG,DET5 NZ protective earthing systems, loop impedance, line-neutral polarity, predictive
Checks resistance of electrical systems including soil resistivity. Measures short circuit current, phase sequence and voltage. RCD current 10mA~1A.
resistance from 0.01~19,999Ω in 4 ranges. LCD 3½ digit display. Operating Tripping time 1~500ms. Tripping current measurement with intelligent ramp.
frequency 128Hz. Complete with earth testing kit including spikes and wire. Fault voltage 0.1~99.9V. Loop and earthing resistance 0.15W~10kW. Earth
electrode voltage (SEV 3569) up to 199V. Short-circuit current 1A~9.99kA.
3M Model 701 Micro-ohm ESD Surface Tester Loop/line internal resistance RLOOP 0.07~200W. Nominal line voltages
3M,701 AU
100~435V. Battery-saving, automatic switch-off, typical battery service-life
Tester for static control surfaces, table mats, field service kits, floor coverings,
3,500 insulation measurements.
etc. Test voltages 10 & 100V. Resistance range 0~100GΩ.
Multi-amp MET-2 Clamp-On Earth Tester
Baur DAP75 Insulating Oil Tester MUL,MET-2 NZ
BAU,DPA75 AU
Clamp-on earth tester 0.01~300Ω. Measures earth resistance by using 2
Output voltage 0~75kV rms. Selectable programmes to international
clamp CTs without disconnecting the earth conductor. Measures dc loop
standards. Integral printer. RS232 interface.
resistance without any influence from other conductors.
AVO OTS60PB Transformer Oil Tester Seaward Europa Advanced Portable Appliance Tester
AVO,OTS60PB AU
SEW,EUROPA PAT AU
Test voltage 60kV max at 61.8Hz. Fully automatic operation. Rechargeable
Records results, compliant with AS/NZS 3760: 2001/2003 can be printed as a
battery operation. RS232C interface.
certificate using the serial/parallel adaptor. Bar-code reader included. Earth
BJM All-Test III Motor, Coil and Winding Tester continuity output current 100mA~25A ac. Range 0.01~20Ω. Accuracy ±5%
BJM,ALL-TEST3 AU of reading ±2 digit. Insulation test range, 100kΩ~100MΩ. Test voltage,
Tester for single or polyphase ac motors, generators, transformers or 250, 500Vdc. Resolution 0.01MΩ. Includes plug adaptor to test, EPODs
dc motors. Use to test any motor, coil or winding to determine insulation and extension leads (IEC - IEC and Australian).
condition between windings, windings and frame, open circuits. Also
measure phase balance and angle. Impedance (z) 5~1,000Ω. Inductance
(L) 0.35mH~1.6H. Capacitance (C) 100mF~50nF. Power factor (Fi) 0~90O.
Insulation 0~20MΩ @ 1kV. Frequency range 100, 300, 850Hz & 2.4kHz
(times 2).

46
electrical POWER
Insulation/Condition/Resistance Testers
Seaward PAT Management Software (WIN) Seaward Supernova XE3760+ PAT System with Printer and
SEW,PATGUARD-SW-WIN AU Scanner
Seaward’s PATGuard Plus takes a significant leap in electrical safety SEW,XE3760PKIT+ AU
management software. Its unique “Drag and Drop” presentation makes SEW,XE3760PKIT NZ
the software intuitive and very easy to use. PATGuard both uploads and Includes results label/tag printer and barcode scanner. Performs all AS/
downloads appliance information and test results from the Europa XE, NZS3760: 2001/2003 compliant tests, including class 1 & class 2 leakage
Europa Plus and Supernova XE. Users have a complete visual overview current 5mA/1mA, an earth conductor bond test up to 25A at 3V (approx.
of all appliances in terms of locations and test status. Appliances are 100W) and 250Vdc MOV insulation resistance tests. Stores 5,000 tests
simply dragged and dropped from one location to another. Repeat testing in internal memory by appliance ID, including test type, detailed results,
requirements are easily displayed allowing scheduling of tests to be test time & date, next test due date, site & location. Calibrated resolution
conveniently managed and uploaded into the appliance tester better than the required 5% of full scale across all ranges as specified by
the Standard. Full QWERTY keyboard, and bar code reader for input.
Trolley Suitable for SEW,XE3760PKIT+ SUPERNOVA PAT Tester Durable plastic adhesive test label/tags printed to attach to appliances and
SEW,TROLLEY-3760PKIT
leads includes user ID (logo optional on request) and test barcode ID, saves
This trolley is specially designed for SEW,XE3760PKIT+ and very useful for
transcription. Compatible with Seaward PATGuard plus software package.
Portable Appliance Tester, Seaward XE 3760 PKIT+. This trolley comes with
the following accessory and contains four layer shelving, extension board
with five socket 240V / 10 Amps, extension cable approximately 25 meters,
2 Nos. of elastic tie rope and a plastic bin. By using this trolley one can fit all
the required instruments for Portable Appliance Testing and this will improve
performance and higher productivity.
Seaward PAC 3760 Appliance Checker
SEW,PAC3760 AU
Performs the following tests in conformance to AS/NZS 3760:2000, earth
bond, insulation & polarity tests, also leakage current tests for Class I &
Class II appliances and leads (leakage current testing of appliances, which
requires power to “switch” them on, is the method required by AS/NZS3760:
2003). Features simple pass/fail indication. Unique 3 button operation.
Class I, class II and leakage current. Automatic test sequence senses
an IEC or extension lead then performs a polarity test. Detects that the
appliance under test is switched “On”. Earth bond test is set at 10A and is
capable of fusing a poor earth. Large LCD.

PRO-TAG Thermal Transfer Printer


PRO,TAG-PRINTER AU
Print durable and permanent synthetic test tags on-site directly from your
Europa XE, Europa Plus or Supernova XE appliance safety testers. Easy
- test the appliance, print the tag, peel it off and stick it on. Accountable - the
Pro-Tag systems are fool proof and tamper evident. Test tags are generated
direct from the tester’s test results. Fast & Cheap - no more hand writing
test tags and Pro-Tag test tags are less than half the price of vinyl tags.
Accurate - tags are printed with appliance number, appliance bar code, test
date, user name and test status from the tester’s memory. Customise - you
can personalise the test tag with your own company logo.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 47
electrical POWER
Power Analysers & Recorders
Volt Current Current (A)
Model Type Features Output
Inputs Inputs (Max,rms)
VOL,PM3000A Power quality/
400 Hz, Harmonics 99th
demand 30 A direct Display, RS232,
3 3 Very high accuracy
1 kA/3kA CT + more
NATA certified unit available
VOL,VPAS Software
Power quality/ Sampling 10MHz
LEM,TOPAS1000 4 4 RS232,Ethernet, software
demand Harmonics 50th
Network 3kA
Interharmonics 5~2,500Hz RS232 serial cable
LEM,MEMOBOX 300 performance 3 4
(in steps of 0.5Hz) CODAM plus software
analyser
Sampling 1Mhz transient
Universal power
DRA-BMI,PX5 3 kA/6 kA Harmonics 63rd 128Mb, compact flashcard
quality/demand
Flicker, Pst, Plt
Sampling 1Mhz transient
Universal power 4 4
DRA-BMI,PX5-400 3 kA/6 kA Harmonics 63rd 128Mb, compact flashcard
quality/demand
Flicker, Pst, Plt
Sample rate 256/cycles
Universal power
DRA-BMI,PG4400 3 kA/6 kA Harmonics 63rd 128Mb, compact flashcard
quality/demand
Flicker, Pst, Plt
Sampling 4MHz
REL,1600 5 5 1 kA Parallel, software
Harmonics 63rd
Sampling 2 MHz Display, ethernet, RS232,
HIO,3196-PQA 5 kA
Harmonics 50th Compact flash card

HIO,3197PQA 5 kA Harmonics 50th Display, USB


Power quality/
CHK,PM20 demand 1 kA/3 kA Sampling 11.4kHz, THD Display, RS232, software
3 4
Sampling 11.4kHz,
CHK,PM30 1 kA/3 kA Display, RS232, Software
Harmonics 48th, IP56
RS232 POWERview
CHK, PM30 Plus THD and individual to 48th harmonics software,
3 kA 4Mb memory
Flexible Cts/Clamp Cts
CHK,PM40PQA RS232, USB, 15Mb Memory
DRA-BMI,PR150 150 A Universal current clamp ac/dc
CT
DRA-BMI,PR1500 1500 A Universal current clamp ac/dc
DRA-BMI,PR6035A/36 Flexible CT 6000A ac Flexible CT, 36” length
DRA-BMI,TR2021 1-30A Instrument CT, 48Hz – 10kHz
DRA,TR2510 10A ac Instrument CT, 1-10A
CHK,CR100 100
CT
CHK,CR500 500
CHK,CRT1000L 1 Ka
CHK,CT3000L 1
CHK,CK1 3ph current 1
CHK,CK5 converter 5

Up to 63rd harmonics & THD


Portable power Sample rate 256/cycle 12Mb internal memory
4 5 6 kA
MEG,PA9 PLUS analyser Current voltage simultaneously 256Mb compact flash card
600~6,000 flexible CTs

Harmonics 25th
ALG,UPM6001 Power demand 3 3+aux 20 A/1 kA Display, printer, RS232,
For 4th current channel of UPM
Power quality/ 20 A direct software
ALG,UPM6100 4 4 Harmonics 50th, 14~500Hz
demand 3 kA
ALG,RET Flexible CT 3 kA
Precision CT for
ALG,C173 1 mA~1 kA
earth leakage

48
electrical POWER
Power Analysers & Recorders
Volt Current Current (A)
Model Type Features Output
Inputs Inputs (Max,rms)
HIO,2331-20RPMS
4 440 0~500 A Remote power measurement Ethernet
HIO,2332-2RPMS
Power demand
500 A~ Display, FDD, RS232,
YEW,CW140 400Hz, Harmonics 13th
700 A optional printer
3
100 direct/ Display, RS232,
AVO, PENTA-PLUS-DMM 3ph DMM/demand 3 ac/dc, voltage phase angle
3 kA CT Parallel printer

BMI,8800 400Hz, Harmonics 30th, Chart, FDD, RS232,


Power Quality 4 4 CTs
Sampling 2MHz Viewing software

BMI,A-111 Voltage plug-in


BMI,A112
600
BMI,A116 CT
BMI,A120
3 kA
DRA,808 Power demand 3 3CTs Chart
DRA,TR2015 CT 3 kA
DRA,635-G5 Termination 5A
DRA,646-3 4 Chart
Power Quality
DRA,626
DRA,PA6030-1 Graphics print out Chart
3
DRA,PA6024A Harmonics 7th
MET,PF-1-F Current logger 69kV RS232, software

MET,MX2040 1ph power demand 2 kA Display, analogue out


1CT
MET,MX200 Clamp on Ammeter 1 200 A Display

LEM,ANALYST-2060 1 ph Power Demand 1 2 kA Harmonics 25th Display,RS232, IR, software

Voltage/Current
HIO,8710 3 3 1500 3 channel recorder, voltage or current Chart
Recorder
Communication
DRA,CAF-RS232 Fibre to RS232 with Node link software
adaptor
Communication Fibre to Ethernet with Node link
DRA,CAF-ETHERNET
adaptor software
DRA,128MBFMC Flashcard Ultra high speed0
Rescue kit for any corrections – logged
DRA,DVMDS Math Driver Software
data
Prepare excitation curves for instrument
PRO,MAGNUS-2.2KV Step Up Transformer 1 1 transformer, demagnetize CT and
conduct trun ratio test on VT
ACR,POWERWATCH Disturbance Logger 1 Voltage disturbance recorder
RS232
HAW,5000 Power demand 3 3 1000 Energy monitoring

DRANETZ ac/dc Current Clamp 3 - 150A Dranetz ac/dc Current Clamp 3 - 1500A RMS
DRA,PR150 AU DRA,PR1500 AU/NZ
AC/dc current clamp/probe 3 - 150A RMS, max conductor size is 52mmØ. Max conductor size is 52mmØ. Current clamp is suitable for any of new
Current clamp/probe is suitable for any of new Dranetz-BMI models DRA- Dranetz-BMI models DRA-BMI,PG4400, DRA-BMI,PX5, DRA-BMI,PX5-
BMI,PG4400, DRA-BMI,PX5, DRA-BMI,PX5-400. Current clamp/probe is 400. Current clamp/probe is very useful for current measurement through
very useful for current measurement through CT current transformer. CT CT current transformer. CT Ratio can be selected on the new Dranetz-BMI
Ratio can be selected on the new Dranetz-BMI above-mentioned models. above-mentioned models.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 49
electrical POWER
Power Analysers & Recorders
Dranetz-BMI Power Xplorer PX5 Dranetz-BMI Power Guide 4400
DRA,PX5 AU/NZ DRA,PG4400 AU/NZ
Provides the full range of measurements include V, I, W, VA, VAR, TPF, DPF, Provides the full range of measurements include V, I, W, VA, VAR, TPF, DPF,
Demand, Energy, Harmonics & Inter-harmonics, THD, Harmonics spectrum demand, energy, harmonics & inter-harmonics, THD, harmonics spectrum
(V, I, W) to the 63rd, Flicker (Pst, Plt), Crest factor, K factor, transformer de- (V, I, W) to the 63rd, flicker (Pst, Plt), crest factor, K factor, transformer
rating etc. Min/Max/Avg values are determined in ½ cycle RMS steps. Asset de-rating etc. Min/max/avg values are determined in ½ cycle RMS steps.
comes with ac flexible current clamp DRA-BMI,RR3035A/24, current range Asset comes with ac flexible current clamp DRA-BMI,RR3035A/24, current
30/300/3,000A ac only. Can be extended to different ranges of measurement range:- 30/300/3,000A ac only. Can be extended to different ranges of
both ac & dc by selecting appropriate current clamps. High-speed transient measurement ac/dc by selecting appropriate current clamps. Has the full
capture (1MHz sampling rate) and the full range of arithmetic, vector and range of arithmetic, vector and sequence parameters to evaluate distorted
sequence parameters to evaluate distorted and un-balanced loads as and un-balanced loads as defined in IEEE 1459. Exceeding high/low limits
defined in IEEE 1459. Exceeding high/low limits of any active parameter of any active parameter can trigger logging. Voltage & current disturbances
can trigger logging. Voltage & current disturbances can be triggered by can be triggered by peak value, wave-shape change & cycle-by-cycle RMS
peak value, wave-shape change & cycle-by-cycle RMS value change. Pre- value change. Pre-event & post-event waveform capture cycles are user
event & post-event waveform capture cycles are user adjustable. Voltage adjustable. Voltage & current channels can be cross-triggered. Suitable for
& current channels can be cross-triggered. Suitable for both ac/dc power both ac/dc power quality measurements.(Universal Power Quality Analysers).
quality measurements. (Universal Power Quality Analysers). DRA-BMI,PX5 DRA-BMI,PG4400 analysers can be used for power quality measurements,
analysers can be used for power quality measurements, current inrush current inrush (cycle-by-cycle current logging), fault recording (cycle-by-
(cycle-by-cycle current logging), fault recording (cycle-by-cycle voltage cycle voltage logging), long term monitoring and continuous logging at 1s
logging), long term monitoring and continuous logging at 1s intervals. Four intervals. Four differential voltages and current channels can also be used
differential voltages and current channels can be used independently. DRA- independently. DRA-BMI,PG4400 is Class A compliant with IEC Standard
BMI,PX5 is Class A compliant with IEC Standard 61000-4-30 ‘Power Quality 61000-4-30 ‘Power Quality Measurement Methods’ (also AS DR04066),
Measurement Methods’ (also AS DR04066), AS61000-4-7 ‘Harmonic & AS61000-4-7 ‘Harmonic & Inter-harmonic Measurements’ and AS61000-4-
Inter-harmonic Measurements’ and AS61000-4-15 ‘Flicker-meter’. All data 15 ‘Flicker-meter’. All data is collected at 256 samples/cycle/channel.
is collected at 256 samples/cycle/channel.

Dranetz Flexible Current Clamp 60/600/6,000A


DRA,PR6035A/36 AU
Dranetz-BMI Power Xplorer PX5-400Hz Set of 3 flexible current clamps 60/600/6,000A RMS, max conductor
DRA,PX5-400 AU
size/length of clamp is 36”. Current clamps are suitable for any of new
Specificaion as above but with 400Hz capability suitable for aviation and
Dranetz-BMI Models. DRA-BMI,PG4400 / DRA-BMI,PX5 / DRA-BMI,PX5-
military use.
400. Current clamp/probe is very useful for current measurement through
CT current transformer. CT Ratio can be selected on the new Dranetz-BMI
above-mentioned models.

Dranetz Current Clamp 1 - 30A 48Hz~10kHz


DRA,TR2021 AU
Set of 3 current clamps 1~30A RMS, 48Hz~10kHz. Max conductor size Dranetz Current Clamp Probe 0~10A RMS
0.47”. Description as for DRA,PR6035A/36 current clamps above. DRA-BMI,TR2510 AU
Set of 3 current clamps 0~10A RMS. Max conductor size 0.47”. Description
as for DRA,PR6035A/36 current clamps above.
Dranetz-BMI, 128 MB Flash Memory Card (Industrial Grade)
DRA,128MBFMC AU/NZ
Suitable for the following Dranetz -BMI Models:- DRA-BMI,PX5, DRA-
BMI,PX5-400, DRA-BMI,PG4400.

50
electrical POWER
Power Analysers & Recorders
Dranetz Communications Adapter - Fibre to Ethernet with Node BMI A116 600 Amp Clamp-on Probe for 8800
Link SW BMI,A116 AU
DRA-BMI,CAF-ETHERNET AU Aperture 50mmØ. Bandwidth 3kHz.
Communications Adapter - Fibre to Ethernet with NodeLink Software and
Moxa Networking Software for the following Dranetz-BMI Models:- DRA-
BMI A120 3000 A Clamp-on Probe for 8800
BMI,A120 AU
BMI,PX5, DRA-BMI,PX5-400, DRA-BMI,PG4400.
Aperture 63 x 160mm. Bandwidth 3kHz.
Metrosonics PF-1-F Overhead Profiler
MET,PF-1-F AU
Distribution line profilers for current measurement on power lines. Logs
current consumption to internal memory. Set of 3 profilers with one display
module. Windows software included. Current range 5~1000A. Resolution
1A. Accuracy 1.5% ±5A. Conductor voltage to 69kV nominal. Sample rate
1s~10min. Memory 64k readings. Data storage modes: stop when full or
wrap around. Data retention after low battery shutdown 30d. Min conductor
spacing 600mm.
Dranetz View Math Driver Software (Add ON)
DRA-BMI,DVMDS
In 4 essential areas, the Math Package will improve measurements:-
AU
> NEW Hioki Remote Power Measurement System 2331-20
RPMS SmartSite
HIO,2331-20RPMS AU
Rescue Kit. Ever hooked up a probe the wrong way? May be forgotten to
For multi-channel power recording 1ph 2 wire up to 6 circuits or 1ph 3 wire &
check if the actual time in your instrument is running correctly? Or could you
3ph 3 wire up to 3 circuits. Provides via a PC, management of measurement
have possibly forgotten to set the correct K-factors? The Math -Package
data to support energy and environmental management. Modulated
helps you to correct these errors, re-calculate parameters from available
measurement units take advantage of a variety of infrastructure to collect
waveform data, invert waveforms and much more. Improve Measurements
measurement data. Use as a stand alone logger and for remote monitoring.
/ Reports. Calculate additional parameters for your Multi-DAQ TASK
Use as a PC measurement logger keeps measuring and continuously saves
Card, fault-recorder/inrush mode measurements, with the math driver the
the data. Measurement modules comes with memory and clock. Build a
following additional trends will be created for Multi-DAQ data files: V rms,
customised and remote measuring system by utilizing existing data network.
Watts, VAR’s, VA, True PF, V thd (%fundamental), I thd (abs current) Voltage
Modules for temperature, humidity, instrumentation and pulse, power module
Frequency (for internal trigg) and Net Totals V rms, Amps, W, VAR & VA.
for multiple circuits. Large internal memory. Communication module with
Generate More parameters from waveform data. Showing Displacement
built-in real-time clock tracks the data of each measurement module to the
Power Factor (DPF) instead of K-factor. Rename inputs. Energy ON/OFF
second. Air Module for constructing SS wireless systems.
peak calculations. Mathematical expressions and formulas can be used
to plot additional user-defined channels within both the time-plot chart
and the waveform chart. Advance analysis, watt harmonics, symmetrical
components, etc.
Dranetz 646-3 Disturbance Recorder
DRA,646-3 AU
Accepts up to 3 ac line inputs 50~600V, 1 neutral to ground input 5~200V,
& 1 dc voltage input 1~100V. Monitors and records impulses, sags, surges,
under and over voltages and frequency variations on 1~3ph ac, 47~63Hz.
Impulse duration 1~1,000µs.
Dranetz 626 Power Disturbance Monitor
DRA,626 AU
For use with up to 5 x PA series plug-ins. Monitors sags, surges, impulses
and changes in frequency.
ACR Voltage Disturbance Logger
ACR,POWERWATCH NZ
Single phase 230V disturbance logger. Plugs into a standard 230V 3pin
power point. Stores up to 4000 events such as sags, surges, outages,
> NEW Hioki Remote Power Measurement System 2332-20
RPMS SmartSite
HIO,2332-20RPMS AU
impulses & frequency variations. Supplied with software & serial cable for
Description as for HIO,2331-20RPMS above.
programing, uploading and printing results.
Hawk 5000 3 Phase Power Demand Logger
BMI 8800 Power Disturbance Analyser HAW,5000 NZ
BMI,8800 AU
Three phase wye power demand logger. Records kVA, kW, V, I, Freq & PF.
Eight inputs giving simultaneous voltage and current (optional probes
Uploads data to a PC for graphing and printing. Supplied with software and
required) monitoring of up to 4 channels each. FDD included. Each
3 x 1kA clamps.
disc stores 600 disturbances for transfer to the internal graphics printer.
Harmonics measurement option included for up to the 40th harmonic of Dranetz 808 Power Demand Analyser
50Hz. Max input voltage 600V rms or dc. Eight extra channels included for DRA,808 AU
sensor outputs, etc. Operates from ac mains or 11~16Vdc. In-built UPS. Displays and prints on in-built printer - V, A, PF, kW, kWh, kV/A, kVAR,
demand, time and date for single and three phase systems. For use with
BMI A-111 ac/dc Voltage Impulse Probe DRA,635-G5 terminations or TR series clamp-on current transformers.
BMI,A-111 AU
For BMI,4800/8800. Uses probe channels to increase the number of voltage Dranetz TR2015 Clamp-on Current Transformer
inputs that can be monitored. Ranges 0~600V rms, 0~100V dc. Impulses DRA,TR2015 AU/NZ
0V~2.4kV peak. For DRA,808. Ranges 1, 2 & 3kA. Requires DRA,635-G5 termination.
BMI A112 Current Probe for BMI 8800
BMI,A112 AU
For BMI,4800/8800. Measures current waveforms to 600A and allows
graphic representation on BMI,4800 printout. Jaw opening 50mm. True
rms measurements for motor startup, current surges, etc. Range can be
extended to 3kA by using DRA,TR2015 in secondary loop configuration.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 51
electrical POWER
Power Analysers & Recorders
Voltech PM3000A 3 Phase Power Analyser LEM Elmes 693 3Ph Power Logger
VOL,PM3000A AU LEM,603 NZ
Capable of making measurements of all standard electrical characteristics Logs, voltage, current & PF. True RMS: VA, VAr, PF, Volts, A & frequency.
of 1 & 3 phase supplies. Measures inrush current and crest factor, load Sampling rate is 1s. Statistical measurement interval can be set from
impedance and harmonic analysis, energy and max demand, extendable 1~60min. Supplied with flexible 1kA Rodowski CTs, 5A clip-on CTs and
using current and potential transformers. Frequency range dc~500kHz. software for programming and uploading results. Accuracy, active power
Parameters W, VA, Var, V, A, PF, peak voltage and current, crest factor, ±2%, reactive power ±3%, phase angle ±3%, voltage ±1.5%.
impedance, peak inrush current, voltage and current harmonics, 99th order,
Reliable Power Systems 1600 Analyser
THD, Hz, Wh, VAh, Varh, Amph, average pf. Input coupling may be ac or ac
REL,1600 AU
+ dc. Outputs printer, recorders (8), and oscilloscopes. IEEE, RS232C, and
Power analyser for parameter, demand, and disturbance measurement
centronics interfaces and waveform output derived from current and voltage
and long term monitoring. PC required for download - no onboard display.
inputs are included. Accuracy V & A 0.05%, power 0.1%. Input ranges
Complete with 1kA CT’s & 5A CT’s. V & I sampled at 8kHz, min/max values
voltage 0.5V~1kV rms, current 0.05~30A rms (200A peak). Accessories
have 1 cycle response. Impulses sampled at 2 & 4MHz software selectable.
3 x 1kA clamp-on CTs, and 3 x precision 100A/1kA dual range current
Max input voltage 700V rms. Notebook PC with Win 95 and Office 97
transformers 0.2% (not clamp on).
included.
Voltech PM3000A with NATA Calibration Algodue UPM6001 Power/Demand Analyser
VOL,PM3000A-NATA AU
ALG,UPM6001 AU
Specifications as above but with NATA calibration.
Includes 3 x 1kA clip-on current transformers. Integral digital display and
LEM Analyst 2060 Hand-held 1 Phase Clamp-on Power Meter printer. Memory 512kb plus RS232 interface for data transfer. Measures
Analyser each phase & total V, A, power, PF, VA, VAR. Measures demand over a
LEM,ANALYST-2060 AU defined interval, harmonic distortion, and provides FFT analysis. Records
Measure, record and log W, VA, VAR, kWh, and power factor. Current to maxima and minima. Current inputs are at 1V or 5A for external CT’s.
2kA auto-ranging ac or dc. Peak, Crest Factor, THD, DF and frequency for Voltage drop detection for durations exceeding 150ms. Software provides
voltage (4~750V) and current. Harmonics to the 25th order. Time base is time plots and remote display of measurement parameters. Higher speed
selectable from 2ms/div~50ms/div. Large backlit multi parameter display, FFT harmonic plot possible up to 25th harmonic.
with oscilloscope and chart modes. Memory size: 8 screens smart save and
Algodue UPM6100 Uni Power Meter 500Hz & Rogowsky 3kA
up to 10,000 readings. Jaw opening capacity 60mmØ. Typical battery (6 x
Options
AA alkaline) life 24h without backlight.
ALG,UPM6100 AU
LEM Topas 1000 Power Network Analyser Power meter 3kA Rogowski current transducer (flexible CTs), 14~500Hz,
LEM,TOPAS1000 AU harmonic distortion current and voltage 50th order. Large 4Mb memory.
Measures all relevant parameters in one measurement system. Inputs
Algodue Ret Set of 3 Rogowski Transducer
(isolated) voltage 4 channels, 200mV~1kV, current 4 channels, supplied
ALG,RET
with 4 x 0~10A, 10~100A ac clamp-on CTs and 4 x (unit powered) 0~3kA
Use with the ALG,UPM6001. Ranges 300A/3kA. Powered from analyser.
LEM-Flex current sensors. Can be configured for 8 voltage channels.
Measuring functions rms, V(U) voltage imbalance, positive, negative & zero
phase sequence, phasor (vector) diagrams, amps (I)a, pf, kVA, kVAr, f(Hz),
energy, on-line oscilloscope, power and multimeter, harmonics (by power/
> NEW Hioki 3197 Power Quality Analyser with 3x1000A
Clamp-on CTs
HIO,3197PQA AU
direction, magnitude & phase), inter-harmonics, THD, flicker, transients Monitors inrush current, voltage swell, voltage dips, transient over-voltage
(100kHz~10MHz), will capture events from 0.1µs in duration. Software and interruptions. Measure and records power and power factor, active/
configured manual or auto trigger levels, ethernet or serial interface, memory reactive energy, demand, load changes (with graph display), voltage and
>540Mb/HDD. current. Measures impulsive voltage quality. RMS voltage quality, voltage
swell, voltage dips & voltage interruption. Power quality, frequency, voltage,
current, current peak, active/reactive/apparent power & power factor
(displaced power factor). Three phase quality, voltage unbalance ratio,
current unbalance ratio, harmonic quality (up to 50th order). Harmonic,
voltage, current, ower, voltage/current phase angle. Total harmonic, voltage
distortion, current distortion (THD-F, THD-R).

LEM Memobox 300 Network Performance Analyser


LEM,MEMOBOX300 AU
Weatherproof (IP65)3ph power analyzer. High accuracy to Class A IEC
61000-4-30. Suitable for 50Hz or 60Hz systems. LEMflex flexible current
probes with ranges 15, 150, 1,500 & 3,000A suitable for conductors up
to 178mmØ. Voltage ranges from 115~830V on 3 or 4-wire systems.
Measures V, A, kW, kVA, kVAR, kWHr, PF, Hz, crest factor, distortion power,
THD, individual harmonics of volts & current up to 50th harmonic, flicker and
ripple control signal levels. Power measurements by either 2 or 3 wattmeter
method. Power supply 88~415V either from measurement leads or separate
supply. Memory size 4Mb with 5,700 sampling intervals. Sampling intervals
selectable from 1s~60min. Sample interval of 5min records for >19Days.
Linear or circular (overwrites earliest data once full) memory. Records
average, 10ms min & 10ms max in each interval. Captures motor start
current spikes with corresponding voltage-dips. Captures up to 13,000
voltage sag/surge events 10ms or longer. Weight 1.1kg.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 53
electrical POWER
Power Analysers & Recorders

> NEW Hioki 3169-20 Clamp-On Power HiTester for Power


Measurements
HIO,3169-20CLAMPONPT AU
Hioki 9694 Clamp-on CT 5A
HIO,9694CT5A
Rated primary current 5A ac. Amplitude accuracy ±0.5% rdg. ±0.2% fs (at
AU

Allows measurement of 1ph~3ph 4-wire circuits with a single unit. In 45~66Hz), 66Hz~5kHz ±1% or less. Max circuit voltage 300V rms/insulated
addition to measuring standard parameters such as voltage, current, power, wire. Core jaw 15mmØ. Size: 46w × 21d × 135hmm, cord length 3m.
power factor, and integrated values, this unit can simultaneously perform
Hioki Clamp-on 100A ac CT
demand measurements required for carrying out power management and
HIO,9660CT100A AU
energy-saving measures, as well as harmonic measurements. Features
Rated primary current 100A ac. Amplitude accuracy: ±0.5% rdg. ±0.2%fs (at
PC card data storage and comes equipped with an RS232C interface for
45~66Hz). 66Hz~5kHz ±1% or less. Max circuit voltage 300V rms/insulated
PC communications. Can measure the power of just a few cycles, enabling
wire. Core jaw: 15mmØ. Size: 46w x 21d x 135hmm, cord length 3m.
more detailed and effective energy-saving measures. Supplied with Hioki
9625 power measurement support software for data analysis. Measure up Fluke 43 Power Quality Analyser
to 3ph, 3 wire system (displays voltage and current for 3 lines), up to 4 x FLU,43 NZ
1ph, 2 wire systems, 5A~5kA range, PC card data storage, power recording Single phase power quality analyzer. Combination power quality analyzer,
for individual waveforms. Simultaneous recording of demand values and multimeter and scope. Scope displays voltage and current waveforms.
harmonics. Applications are energy maintenance/control, energy control Measures true-rms voltage, current and frequency. Measures voltage,
under ISO 14000, saving energy activities, power consumption measurement current, and power harmonics up to 51st harmonic. Total harmonic distortion
of specific device/equipment, harmonic analysis. (THD). Phase angle of individual harmonics. Continuously measure volts
and amps on a cycle-by-cycle basis for up to 24h. Use cursors to read time
and date of sags and swells. Supplied with 500A current probe, software
and cable.
Fluke 43B 1 Phase Power Quality Analyser
FLU,43B NZ
Combines the capabilities of a power quality analyser, scope and multimeter
in a single easy-to-use instrument. EN 61010-1 CAT II, 600V. UL and CSA
listed. Recording times 4min~16d (selectable).
Megger PA9Plus Portable Power Quality & Demand Analyser
MEG,PA9PLUS AU
> NEW
HIOKI 3169-21 Clamp-On Power HiTester
HIO,3169-21 CLAMPONPT au
Integral graphic backlit LCD and compact flash card memory. Measures
and records all voltage/current power and waveform activity. Input voltage,
4 differential channels auto ranging between 20~300, 300~600V ac, V dc
Measure up to 3-phase, 3-wire system (displays voltage and current for
scales, accuracy ±0.25% of reading, ±0.05% of range to the 63rd harmonic.
three lines), Measure up to four single-phase, 2-wire systems, 5A~5000A
Crest factor voltage 3.5 limited to 1.5kV peak. Current 1.4 of full scale at
range. Compact and light weight, PC card data storage, power recording
peak input. Current 5 channels resolution 0.1% fs, accuracy ±0.25% of
for individual waveforms, simultaneous recording of demand values and
reading, ±0.05% of range to the 63rd harmonic. Frequency fundamental
harmonics. Main applications: energy maintenance/control, energy Control
50Hz response dc to 3.15kHz (63rd harmonic). Resolution 0.01Hz. Sample
Under ISO 14000, saving energy activities, power consumption Measurement
rate 256/cycle current and voltage simultaneously. Harmonic distortion
of specific device/equipment and harmonic analysis. Complete with RS232C
current and voltage to the 63rd order and THD. Power supply 90~600Vac,
interface for PC communications. Supplied with Hioki 9625 Power
50Hz, 100~600Vdc either via channel 1 or from independent IEC lead.
Measurement Support Software for data analysis.
Memory 12Mb internal, 512Mb compact flash card. Current sensors 4 x
Hioki 3196 3 Phase Power Quality Analyser 600~6,000A Rogowski flexible. Report generation software included. Set-
HIO,3196-PQA AU up and download can be done through RS232 or flash card.
High speed (0.5µs 2MHz) field unit. Channels 4 voltage, 150~600V rms 4
ranges (isolated), 4 current 0~5kA (3ph and neutral) rms 2 ranges. Supplied
with 4 x 5kA flexible clamp-on CTs (length 945mm). Memory 13Mb internal,
> NEW CCI Power-Mate 15A Single Phase Power/Energy
Measurements
CCI,POWER-MATE 15A au
512Mb compact flash card. Display internal high resolution colour LCD.
Can accurately measure and calculate power, volts, amps and energy being
Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, (THD and individual to 50th
used by an electrical appliance. Also measures the greenhouse gas emission
order) flicker IEC6100-4-15. Total energy, tariffs, max demands, transient
created by an appliance. Can determine the actual running cost, how much
and sub-cycle disturbances. Software provides graphs and summaries to
energy the appliance used in kilowatt-hours and how many kilograms of
PC. Interfaces RS232 and 10base ethernet.
greenhouse gas emissions it produced all in hourly, yearly, quarterly and

> NEW
Hioki 9670 Thermal Printing Method Printer, Input RS232C
HIO,9670 Printer AU
accumulated figures. Features an LED display for easy reading and high
visibility at all times. 15-amp version - to a maximum continuous capacity of
15A, but readings are accurate to 18A and the cable is rated to 15A. Provides
Uses stationary type, thermal printing method printer which prints date input a variety of measurements including: power in watts, voltage and current.
via RS232C from a computer or the other host system. Convenient battery Provides the minimum, maximum as well as instantaneous readings.
that makes easy to carry around. Provides high-speed printing with very
little noise. Provides clear printing of 16 x 16 dots and 24 x 24 dots (as
well as Japanese characters JIS Level I and II), and can print bar codes.
Provides various settings such as enlarged-character printing. Graphics can
be printed using bit images.

54
electrical POWER
Power Analysers & Recorders

> NEW
CHK Gridsense PM40 Power Quality Analyser
CHK,PM40PQA
GridSense CHK PM30 Plus 3 Phase Powermonic Logger/
Logger
CHK,PM30PLUS AU
Weatherproof IP65 field unit. Channels: 3V, 63-440V (isolated). 4 current Weatherproof IP65 field unit. Channels 3 voltage, 63-440V (isolated), 4
0 to 3,000A (3ph and neutral) rms. Supplied with 4 flexible 3,000A clamp- current 0 to 3kA (3ph & neutral) rms. Supplied with 3 x flexible 3kA clamp-
on CTs (flexible CT length 600mm and Diameter 190mm). (In addition, on CTs (flexible CT length 600mm & 190mmØ). Clamp-on CTs of 3kA,
clamp-on CTs of 3,000A, 1,000A for large conductors and 500A and 100A 1kA for large conductors and 500A & 100A for neutral conductor current
for neutral conductor current measurement are available.) Memory: 15 Mb. measurement are available. Memory 4 Mb. Inbuilt 2 line LCD display.
Inbuilt Graphic 128x64 bits LCD display, 7 rows x 20 characters. Records: V, Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, (THD and individual to
A, pf, f(Hz), kVA, kVAr, kW, harmonics, Inter harmonics, voltage and current 48th ). Total energy, tariffs, maximum demands, transient and sub-cycle
imbalance (THD and individual to 48th ) and Flicker. Total energy, tariffs, disturbances. Software provides graphs and summaries to PC. Download
maximum demands, and transient and sub-cycle disturbances. Included files while logging via RS232 interface. PC using Win 95, 98, NT4, 2000,
software provides graphs and summaries to PC. Download files while XP, O/S, is required with the CHK POWERview software to configure this
logging USB interface. A PC using Windows 95, 98, NT4, WIN2000 or XP unit before operating.
O/S, is required with the CHK PowerView software to configure this unit
before operating.







the latest addition to the rugged, weatherproof and versatile
powermonic range has 
features including:
• flicker monitoring
• interharmonics
• voltage unbalance
• increased memory capacity (15mb)
• larger lcd display
• real-time data display
• compliance to all iEc pq standards
• high-speed usb data transfer

Other features include:


• tables & graphs of 3 phase v,a, pf,dpf, kw, kva, kvar, thd,
harmonic phase angle, individual harmonics, interharmonics,
frequency, all to iEc standards
• total Energy & tariffs calculator
• ability to capture motor starts, high speed rms & waveform
disturbances
for more information visit - http://www.gridsense.net

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 55
electrical POWER
Power Analysers & Recorders
CHK PM30 3 Phase Powermonic Power Logger Martindale Phase Sequence & Continuity Indicator 100~600V,
CHK,PM30 AU/NZ 50/60Hz
Weatherproof IP65 field unit. Channels 3 voltage, 63~440V (isolated), 4 MAR,PSCI424-585 AU
current 0~3kA (3ph & neutral) rms. Supplied with 3 x 1kA clamp-on CTs Tester may be used, on 3ph circuits, to check the presence & sequence
(cable capacity 50mm). Clamp-on CTs of 3kA, 1kA for large conductors of the phases. Important on motor circuits as a phase reversal will cause
and 500A & 100A for neutral conductor current measurement are available. a motors direction to reverse. Tester will give visual indication of loss of
Memory 4Mb. In-built 2 line LCD display. Records V, A, pf, f(Hz), kVA, phase or an incorrect sequence. Tester is supplied in 2 forms - Probe style,
kVAr, kW, harmonics, (THD and individual to 48th ). Total energy, tariffs, the connection to the tester is via 3 insulated cables to 3 fused test probes,
max demands, transient and sub-cycle disturbances. Software provides 1 with an insulated crocodile clip. Plug style, a 16A, 4 pin, 3ph & earth,
graphs and summaries to PC. Download files while logging via RS232 BS4343 plug is fitted to the tester. Use as a socket tester prior to plugging
interface. PC using Win 95, 98, NT4, 2000, XP, O/S, is required with the in 3ph equipment. Testers supplied in a plastic wallet, with full instructions.
CHK POWERview software to configure this unit before operating. Caution, the unit should be checked for correct operation using a known
voltage before use.
CHK PM20 Power Quality Analyser/Logger
CHK,PM20 AU
Three phase, weatherproof IP65 field unit. Three voltage channels 63~440V
(isolated). Four current channels 0~3kA rms (3ph & neutral). Supplied with
3 x 1kA clamp-on CTs (cable capacity 50mm), 3kA for large conductors and
500A for neutrals clamp-on CTs are available. Memory 4Mb. In-built 2 line
LCD display. Records V, A, pf, f(Hz), kW, kVA, kVAr, THD, total energy and
tariffs, high speed rms waveform capture events outside preset limits (10ms
intervals). Software provides graphs and summaries to PC. Download
files while logging. RS232 interface. PC using Win 95, 98 or NT4 O/S, is
required with the CHK POWERview software to configure this unit before
operating.
CHK 3 Phase Converter for CTs 1A Input to 200mA Output Yokogawa CW140 Demand/Harmonics Analyser
CHK,CK1 AU YEW,CW140 AU/NZ
Adaptor for CTs with 1A secondary outputs, this unit suits CHK,PM30/20. Includes 4 x 500A clip on current transformers, jaws 30mmØ inside. Current
transformers are accurate at currents of <1A. For current applications in
External Modem 56k Remote Communication for CHK,PM30/ excess of 500A use DRA,TR2015 & TR,CT-5. Has wiring check maps,
PQA power, VAR, Hz, VA, PF. Works at frequencies from 45Hz~1kHz. Harmonics
CHK,MODEM-56K AU
to 13th order. Electric energy mode to measure Wh, Varh. Monitor and
External modem 56k for CHK PM20, CHK PM30, CHK PM30PLUS or any compare 2 separate loads. Event and external trigger inputs and D/A
other power quality analyzer. Modem gives remote access control to set- outputs. Portable battery powered with large LCD screen and soft keys for
up/download any connected Instrument. operation. Supplied with Rion CP-10 printer.
CHK 3 Phase Converter for CTs 5A Input to 200mA Output
CHK,CK5 AU
Adaptor for CTs with 5A secondary outputs, unit suits CHK,PM30/20.
CHK CR100 Clamp-on CT
CHK,CR100 AU
Jaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as fourth CT to
measure neutral current. Accuracy Class 1.
CHK CR500 Clamp-on 500 CT
CHK,CR500 AU
Jaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as fourth CT to
measure neutral current. Accuracy Class 1.
Programma Magnus 2.2kV Step Up Transformer for Testing
CHK CT1000L Large 1kA Primary Clamp-on CT CT’s
CHK,CT1000L AU
PRO,MAGNUS-2.2KV AU
Large 123 x 35mm 1kA primary clamp-on CT for CHK,PM20/30. Use in high-voltage substations and industrial environments. Protected with
Gridsense 3000 Amps Flex CT 600 mm thermal cut-outs, mains voltage 230Vac ±10%, 50~60 Hz, power consumption
CHK,CT3000 PLUS AU is 2.3kVA. Used for preparing excitation curves for instrument transformers
and for demagnetizing current transformer cores quickly and easily. Also
CHK CT3000L Large 3kA Primary Clamp-on CT used to conduct turn-ratio tests on voltage transformers. Provides 1A at
CHK,CT3000L AU
2.2kV output. Two-hand control enhances personal safety. Weighs 16kg.
Large 123 x 35mm 3kA primary clamp-on CT for CHK,PM20/30. Supplied with a special high-voltage cable and robust transport case.
Metrix MX200 ac/dc Clip-on Power Meter
MET,MX200 AU/MY
Ranges 19.99 & 199.9A. Measures voltage to 750V, frequency to 999Hz,
power 1.99 & 19.99kW, apparent power 1.99 & 19.99kVA, & pf. Recorder
output via special leads (supplied) for current range only, 5mV/A on 199.9A
range. Switch in battery compartment gives ac as well as dc output. Internal
battery for 70h operation. Clamp capacity 23mmØ or 20 x 10mm bars.
Metrix MX2040 ac/dc Clamp-on Meter
MET,MX2040 AU/NZ
Measures A, V, Hz, kW, kVA, kVAR, kWH, PF and resistance. Ranges 200A
& 2kA, 600V & 1kV, 20, 200kW & 2MW & kWH. Scale length 3,000. 1 &
3ph operation. Motor rotation indication. Peak, min, max, average, rms, and
crest factor indication. Peak response time 1µs. Analogue output option
fitted giving dynamic signals and calculated parameters (energy, etc).

56
electrical POWER
Protection Relay Testing Systems

> NEW
Omicron CPC 100 PTS for CTs/VTs/Power Transformer
OMI,CPC100PTS au
Omicron CMGPS Syncronisation Control Unit
OMI,CMGPS
GPS-based synchronisation unit, which is used to synchronise CMC
AU

Allows for automated testing of power transformers, CTs, VTs, resistance (Protection Relay) test sets. Used when performing end-to-end tests of
testing, and more. Providing up to 800A (or 2000A with current booster) and line protection schemes, the unit provides a start signal pulse based on the
2000V and comes complete with an integrated PC. Its software routines test a GPS clock time base. Software is both integrated in the testing modules
wide range of substation equipment, and automatically creates customizable (State Sequencer) and can also be used as a stand-alone application. Two
reports. Weight: 29 kg. Analog voltages and currents can be measured with independent timing pulses are available via separate connectors, on a 16-
very high precision. Its Ohm meters automatically switch ranges from µOhm pin plug (pulse out 1) which is connected with the CMC test set (external
to kOhm to allow for a wide variety of applications. Testing of unconventional interface) and on 2 x 4mm banana plugs (pulse out 2). Supplied with GPS
equipment, such as Rogowski Coils or current sensors completes the antenna, 15m antenna ext cable, plug-in power supply, CMC-CMGPS
spectrum. Safety features: emergency shut off button, safety key lock (block interface cable, users manual, fabric carry bag and a travel case. Weighs
unauthorised use). 5kgs.
Omicron C-Probe-1 Clamp-on CT ac/dc
OMI,C-PROBE1 AU
An active ac & dc current probe with voltage output. Recommended
accessory for measuring currents with the CMC 256. Two measuring ranges:
10A & 80A. Frequency range dc 10kHz. Accuracy error < 2% for currents up
to 40A and frequencies up to 1kHz. Phase error < 0.5O @ 50/60Hz. Length
230mm.
Omicron CMC256-6 Advanced Protection Relay Test Set
OMI,CMC256-6 AU
Advanced 3ph dynamic automatic protection relay test system. Current,
integral 3ph current source max 140VA, 6 output sources, resolution 500µA,
suitable for most relay types, including some high burden units. Voltage,
3ph 0~300rms. Auxiliary dc supply, 0~264V, 0.2A. Relay monitoring trip,
monitoring 6 isolated inputs, can be configured to be voltage free or 0~250V.
Omicron CMC156-3 Advanced Protection Relay Test Set Contact outputs 6 isolated change-over relay contacts (software controlled).
OMI,CMC156-3 AU Max 250Vac, 10A or 125Vdc 1A. Interface connector, 16 TTL digital inputs
For three-phase testing of relays, meters and transducers, for applications and outputs. Scope analogue inputs, 2 isolated analogue inputs ±500V
requiring portability. • 3 x 125V outputs, • 3 x 12.5A outputs, • 6 x low level peak max 12 bit resolution. Input supply 90~260Vdc, 400Hz. Intuitive on-
outputs (rear side), • 2 x counter inputs (rear side), • 4 x binary outputs, • line help. Laptop and Test-Universe software up to TU V 2.01 supplied with
dc measuring inputs, • 10 x binary inputs. Applications are digital distance test set, interface parallel port.
relay testing or testing of transformer operated energy. Signal generation
is performed digitally. The 16-bit D/A conversion results in a high quality
signal event at small signal amplitudes. In addition to the 6 outputs of the
amplifier section, 6 independent channels with low-level signals are available
at the back of the unit which can be used to control external amplifiers for
applications requiring more than 3 voltage or current phases, e.g., testing
of differential relays, or applications requiring higher currents or voltages.
They are also useful where there is a need for output power higher than that
provided by the CMC 156. Comes with Test Universe 2.01 software loaded
on dedicated laptop. Weighs 9.8 kg.

Programma Sverker 760 Relay Test Set


PRO,SVERKER760 AU
Relay test set for 1ph protective relay equipment. Three phase relays can
be tested 1 phase at a time or by synchronising more than one unit. Current
ranges to 100A with full load current to 250A. AC outputs to 250V & dc
outputs to 300V. In-built capacitor and resistors for current output phase
shifting (3600). In-built timer, ammeter, and voltmeter. Measures phase
Omicron CMC256-6 EP Advanced 3Ph Protection Relay Test angle, PF, and impedance. RS232 communications and control interface.
System
OMI,CMC256-6 EP AU
Current integral 3ph current source max 140VA, 6 output sources, resolution
500µA, suitable for most relay types, including some high burden units.
Voltage 3 ph voltage 0~300rms. Auxiliary dc supply, 0~264V, 0.2A. Relay
monitoring trip, monitoring 6 isolated inputs, can be configured to be voltage
free or 0~250V. Contact outputs 6 isolated change-over relay contacts
(software controlled). Max 250V ac 10A or 125V dc 1A. Interface connector,
16 TTL digital inputs and outputs. Scope analogue inputs, 2 isolated
analogue inputs ±500V peak max 12 bit resolution. Input supply 90~260V
dc, 400Hz. Intuitive on-line help. Notebook 486 or better Win 3.11, 95, 98 or
NT, display SVGA or better. Interface parallel port.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 57
electrical POWER
Protection Relay Testing Systems
T&R DVS3-HP Static Relay Test System
T&R,DVS3-HP
Test system for testing voltage and frequency protection relays and
AU > NEW
Programma EGIL Circuit Breaker Analyser
PRO,EGIL-CB ANALYZER AU
transducers. Tests Automatic Voltage Regulating (AVR) relays with line drop One main contact per phase. Three time channels are connected together
compensation, under and over voltage relays, directional over~current relays, on one side. Events at parallel contacts equipped with pre-insertion resistors
df/dt (ROCOF) relays, vector surge (step change of phase) relays and check are recorded and displayed simultaneously. Two separate time channels
synchronising relay. Generates a 3ph voltage output from a 1ph supply, for measurement of auxiliary contacts. On-site hookup comes with ready-
and may be used in conjunction with a current source to test directional made multi-cable sets for both main and auxiliary contacts. Coil currents
protection. Requires 1ph 50/60Hz supply of 115V or 230V (±15%). Unit are measured automatically, presented together with other readings
automatically selects the correct range. Max power requirement of the unit immediately after testing on the display window or via the built-in printer. A
is 0.5kVA. DVS3-HP has 3ph star connected output and the rating of each built-in sequencer (program unit) sets the instrument automatically for the
phase is:- voltage 0~133V phase to neutral, current 5min on/15min off 330mA next sequential breaker operation. Intended primarily for measuring travel
@ 133V, or 200mA continuous, phase lock 45Hz~65Hz., variable frequency (motion). Can be equipped with an optional serial interface (RS232C) for
40~999.9Hz., variable phase angle ±180O. Delta loads may be connected communication with a PC and the CABA Win Breaker Analysis Software.
directly to the output or through the DVS-T VT box. Max voltage obtainable
is 133V between any phase & neutral and 266V between 2 phases (if the
phase angles of the 2 phases are set to 180O apart). DVS-T VT box may be
used to double these output voltage (Ratio 1:2).

More tools for commercial and plant technicians.


Get the job done faster and more accurately with Fluke’s innovative set of tools for electrical
test. From IR thermometers to clamp meters, every rugged tool delivers the reliabilty, accuracy
and safety you expect from Fluke.
Power Quality compliant load studies, energy consumption
testing and general power quality logging.
Verify your power. The Fluke 1735 Power Logger is the ideal technician’s tool for conducting
30-day load studies.
• Set up in seconds
• Measure all 3 phases and neutral
• Log most electrical parameters, plus harmonics and voltage events
More information and resources.
You can always count on Fluke for the troubleshooting techniques, application information, and
training to keep your electrical systems up and running.

Fluke Australia Pty Ltd.


Fluke. Keeping your world Phone: (02) 8850 3333
up and running. Fax: (02) 8850 3300
Email: sales@fluke.com.au
©2006 Fluke Corporation. All rights reserved. Ad 01981

Get more done.


Power Quality Earth Ground Insulation Testers Thermal Images
Analysers Testers

58
electrical POWER
Hi Pot Testers
High Voltage Test Set 30kV/50 Hz AC Hi Pot Tester T&R kV30-40, 30kV ac Hipot Test Set
HIV,PFT303 AU T&R,KV30-40 AU
Rated 1kVA into resistive load, 3kVA into capacitive load. Duty cycle at 3kVA 0~30kV, max output 40mA with a duty cycle of 5min on & 15min off. Max
1/2 hours on 2 hours off, at 2 kVA 1 hour on 1 hour off. For a field and repair continuous current 20mA. Overload trip may be set from 4~44mA. Zero
shop HV testing applications. Tests the integrity of items including insulating interlock and key operated safety features.
materials, isophase bus duct, switchgears, transformers, vacuum bottles &
interrupters, vacuum switches, automatic circuit reclosers, bushings, fuses,
arrestors, circuit breakers, transformers, capacitors, motor and generator
windings.

High Voltage Test Set VLF 90 Kv


HIV,VLF90 AU
Very low frequency (VLF - 90 CM) ac hipot test set with 90kVac peak output,
is suitable for testing cables up to 50kV. High load capacity enables it to test
High Voltage PFT503, 50kV ac Test Set up to approx 7 miles of cable, depending on type. Model includes a charging
HIV,PFT503 AU current and load capacitance meter, test dwell timer, and polarity indicating
Rated 1kVA into resistive load, 3kVA into capacitive load. Duty cycle at 3kVA lights. Output voltage & frequency,- sinusoidal 0~90kVac peak & selectable,
½h on 2h off, at 2kVA 1h on 1h off. 0.1, 0.05,0.02Hz. Test frequency and rated loads with approximate cable
High Voltage Inc Very Low Frequency (VLF) 6022 60 kV Hi-pot lengths are:- 0.1Hz/0.55µF 1,673m of cable, 0.05Hz/1.1µF 3,353m of cable,
Test Set 0.02Hz/2.2µF 6,706m of cable. Kilovoltmeter scaled 0~100kVac peak,
HIV,VLF6022 AU ammeter scaled 0~100mAac & 0~6µF load capacitance. Weight of the unit
For field testing of ac high/medium voltage cables, bushings, and insulators. 167kgs. HV Cable output is 6m flexible, shielded x-ray with alligator clamp,
Input 230V, 50Hz, 6A peak, 2.5A average. Output sinusoidal, 0~60kV ac inter connect cable length 3m, shorting stick 6m lead with clip.
peak, frequency 0.1, 0.05 & 0.02Hz. Duty continuous. Test load capacitance
1.1µF (approx 3kms of cable at 0.1Hz), 2.2µF (approx 9 of cable at 0.05Hz)
& 5.5µF (approx 13kms of cable at 0.02Hz). Display 0~60 peak kV.
Interconnect cable length 3m, control unit to HV transformer. RG8/U output
cable length 3m. Shorting stick braid 6m. HV tank and control units shipped
in travel cases weighing 70 & 40 kgs respectively.

High Voltage Inc VLF 4022 40kV Hi-pot Test Set


HIV,VLF4022 AU
For field testing of ac medium voltage cables, bushings, and insulators.
Consists of control unit and HV tank. Input: 230V, 50Hz, 6A peak, 2.5A
average. Output sinusoidal, 0~40kVac peak, frequency 0.1, 0.05 & 0.02Hz.
Duty continuous. Test load capacitance 1.1µF (approx 3kms of cable at
0.1Hz), 2.2µF (approx 9kms of cable at 0.05Hz) & 5.5µF (approx 13kms
Baur PGK80 High Voltage (80kVDC) Insulation Tester of cable at 0.02Hz). Display 0~40 peak kV. Interconnect cable length 3m.
BAU,PGK80 AU RG8/U output cable length 3m. Shorting stick braid 6m. HV tank and control
Max output 80kV at 0.8mA. In-built timer, zero start interlock and automatic in travel cases weighing 50 & 35kgs respectively.
discharge device. Danbridge Type JP30A Insulation Tester
DAN,JP30A AU/NZ
Megger FT6/12 Ionisation, Leakage and Breakdown Tester
MEG,FT6/12 AU/MY DC high voltage insulation tester. Output voltage 0~3kV, 0~10kV, 0~30kV,
AC ranges 0~2kV, 0~6kV, dc ranges 0~4kV, 0~12kV. Output currents in 3 ranges. Max output short circuit 2µA. Audible indication of ionisation.
7.4mA, 8.9mA ac & 2.1mA, 2.5mA dc. Breakdown and flashover indication Current and voltage meters which may be used to calculate resistance.
by latching indicator for periods exceeding 1ms. Current threshold Megger BM80 Insulation Tester
100µA~1mA. Ionisation indication by internal speaker. Meter indication of MEG,BM80 NZ
ac, dc and ac capacitive currents. Complete with probes. Analogue/digital insulation and continuity tester. Insulation test voltages are:
50, 100, 250, 500, 1,000Vdc. Resistance resolution is 0.01 MΩ. Voltage
range is 0~600Vac.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 59
electrical POWER
Electrical Transducers
Model Type Input Type (V) Input Ranges Output (V)
CAT,CL-8-36 PH STICK Indoor two-pole tester 2~36kV
MEG,DH2-6M Duplex handspikes for 10AmΩ meter 30Vac/dc 20A max.
HIO,9661-01 500A
Clamp-on sensor
HIO,9669-CCT-1000A 1,000A 500-mVac
HIO,9667-FCT-5000A Flexible clamp-on sensor 500A/5,000A
UNI,P75-3C HYBRID-DP 2Vac/dc 7,5000A/1.5V
HIO,3290CLAMPONAC/DC Clamp-on dc to 15kHz 2840A peak 1mV/A
CHK,CR100S 100A
LEM,CURRENT PROBE10A
YEW,3228-11 High sensitivity clamp-on ammeter ac/dc current 50mA, 20A ac/dc 0~100mV ac/dc
High sensitivity clamp-on ammeter & earth
ALG,C173 Algodue only 0.001 ~ 1,000A 1mV~1V/A
leakage
HIO,3128 Clamp-on ammeter ac current 15A, 1.5kA 0~200mV dc
HIO,3285 200A, 2kA, 1kHz 0~1 ac/dc, 0~1 V
BEL,CG-120A 50, 500A 0 ~ 0.5 ac/dc
ac/dc current
UNI,P75-3C Current clamp 4, 7.5kA 0~2/ 0~1.5 ac/dc
HIO,3109 100, 250, 500,1kA 0~1 dc
CHA,D35N 1, 2, 3kA 0~5A ac
FLU,80I,100S 0~10, 0.5~100, 5~1000A 1mA/A
YEW,2215 Current shunt 1A, 1kA 0~50mV ac
ac current
JR,CT-005 ac current dc volts 1, 2, 5kA 0~1dc

ROB,543 1A ~ 2MA 0~2 ac


Rogowski coil
LEM,LEM-FLEXII 30, 300, 3kA 0~3 ac
LG,FIC-51E True RMS transducer 500V 0~5 dc
TR,M05 Instrument transformer ac voltage 100V, 500V rms 0~5 ac rms
YEW,2261-01 Med voltage transformer (3.3kV) 220, 440V,2.2, 3.3kV 0~110 ac
MOR,FDT 0~20ac 50~1.6kHz 1~5 dc
CI,253/50 0~1mA
Frequency transducer 240 ac 45~55 Hz
CT,891040-240 0~10 V dc
CT,891040-110 110 ac 55~65 Hz 0~10 V dc
CWE,230V Transducer ac voltage 230V 1mV/1V
CAR,3-TRANS Converter ac current 5A 0~10V dc

> NEW CATU C-8-36 Phasing Stick-Two pole Phase


comparator for Indoor Use
CAT,CL-8-36 PH STICK AU
Detect differences in voltage between any 2 points of an installation indicated
by LED’s. Enables assessment of the residual voltage induced by nearby
live lines or circuits, and differentiates it from the one provided directly from a
high voltage source. Features, range of voltages 2kV~36kV, high luminosity,
compact 0.62m with probes dismounted, high dielectric quality insulating
material, 2 x 1.25m elements with removable probes, connected via a high-
insulation lead, max use distance 2.25m (with probe extenders), operation
testing with a checking device.

60
electrical POWER
Electrical Transducers
> NEW
Megger DH2-6 Test Lead, 6m long for 10A mΩ Meters
MEG,DH2-6M AU
> NEW
Hioki Flexible Clamp-on Sensor
HIO,9667-FCT-5000A AU
Duplex handspikes (2) with spring loaded helical contacts test lead suitable 10Hz~20kHz, 500/5000A rated, 500mVac fs output, jaw 254mmØ max.
for any 10AµΩ meters (like MEG,DLRO10, MEG,DLRO10X, CRO,DO7 Rated input current 500Aac, 5000Aac, rated output current 0.5 Vac, accuracy
and CHK,LMO5), Used for 4 terminal measurements with low resistance Ω (at 45~66 Hz). Amplitude ±2% rdg ±1.2mV, fs is the 3196 range value.
meters, double, individually sprung, hardened and nickel plated, spike prods Phase ±1° or less. Frequency characteristics 10Hz~20kHz max. Allowable
for good contact. Potential lead and spike marked for easy identification, input continuous 10000Arms (45~66 Hz) max. Circuit voltage 1000Vac rms
suitable for use in potentially corrosive conditions. Body moulding resistant (insulated wire). Dimensions 254w x 86h x 30dmm. Sensor length 910mm.
to aviation “Phosphate ester” fluids. Current rating: 20A max. Working Suitable for Hioki models: 3196PQA, 3197PQA, 3169-20CLAMPONPT,
voltage: 30Vac/dc. Resistance of leads: each lead 20mΩ maximum. 2331-20RPMS, 8715-01, any data logger/scope which takes up to 1.7mVac
input.
> NEW
Hioki 9661-01 CCT-500A Clamp-on Sensors
HIO,9661-01 CCT-500A AU
500A rated, 500mVac fs output, jaw 46mmØ. Rated input current 500Aac,
rated output current 0.5Vac, accuracy (at 45~66Hz). Amplitude ±0.5%rdg,
±0.2%f.s., fs is the 3196 range value, phase ±0.5° or less, frequency
characteristics 66Hz to 5 kHz (±1%), max. Allowable input continuous
550 Arms (45~66Hz), max circuit voltage 600Vac rms (insulated wire).
Dimensions 77w x 151h x 42dmm, cord 3m. Suitable for Hioki models:
3196PQA, 3197PQA, 3169-20CLAMPONPT, 2331-20RPMS, 8715-01, any
data logger/scope which takes up to 1.7mVac input.

> NEW Universal Technic Clamp-On AC/DC Current Probe


4000/7500A
UNI,P75-3C HYBRID-DP AU
Ranges 7,500A/1.5V & 4,000A/2V with hybrid power fitted for battery and
external power supply, 3V operation. Safety sockets 4mm. Clamp is
suitable for use with any instrument with an input range of 2Vac or dc, and
an input impedance greater than 10kΩ. e.g. voltmeter, chart recorders,
oscilloscopes, and power quality analysers.

> NEW
Hioki 9669-CCT-1000A Clamp-on Sensors
HIO,9669-CCT-1000A AU
Jaw 55mmØ, 80mmx20mm busbar. Rated input current 1000Aac, rated
output current 0.5Vac, accuracy (at 45~66Hz) amplitude ±1% rdg, ±0.01%
fs, fs is the 3196 range value, phase ±1° or less, frequency characteristics
66Hz~5kHz (±1%), max. Allowable input continuous 1000A rms
(45~66Hz), max circuit voltage 600Vac rms (insulated wire). Dimensions
99.5w x 188h x 42d mm, cord 3m. Suitable for Hioki models 3196PQA,
3197PQA, 3169-20CLAMPONPT, 2331-20RPMS, 8715-01, any data
logger/scope which takes up to 1.7mVac input.
> NEW
Hioki 3290 Clamp-On ac/dc HiTester
HIO,3290CLAMPONAC/DC AU
Current Measurement at dc and from 1Hzac~1000Hz. Current Clamp
Hioki 9693 Clamp-on ac/dc sensor ranges - 20, 200 & 2000A, jaw opening
55mm.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 61
electrical POWER
Electrical Transducers
> NEW
CHK,CR100s Clamp-On CT 100A
CHK,CR100S AU
> NEW
Cambridge Frequency Transducers 891040 55~65Hz 110Vac
CT,891040-110 AU
Suitable for CHK power quality analysers like CHK PM20, PM30, PM30 Plus Frequency transducer for frequency from 55~65Hz with analogue voltage
and PM40. output 0~10Vdc. Powered from 110Vac only.
Algodue C173 Precision Clamp-on CT Microamps to 1Ka
ALG,C173 AU
High resolution clamp-on CT, for measuring differential and or earth loop or
leakage current. Compatible with Algodue UPM6001 and the later UPM6100
analyser’s fourth current channel. Current range 0.001~1.2, 0.01~12,
0.1~120A & 1A~1.2kA. Bandwidth 10Hz~3kHz. Max jaw opening 53mm.
Bell CG-120A Current Gun (Clamp-on Probe)
BEL,CG-120A AU
Clamp-on hall effect current probe. For primary 0~500A ac or dc (two scales
0~50 & 0~500). Frequency response dc to 1kHz. Output 0.5V full scale
suitable for DMMs. Termination shielded 4mm banana plugs. Jaw opens to
accept 19mmØ conductors. Battery 9V alkaline typical life 100h.
> NEW
HK,CR200 Clamp-on CT 200A~200mA, 2.2Ω Burden Class I
CHK,CR200 AU
230Vac to 230mVdc Transducer
CWE,230V AC NZ
CT 200A~200mA, 2.2W Burden Class I, IEC 185-1987. Suitable for any of Interface with output to 4mm banana male plugs suitable for connecting to
the CHK Powermonic Power Quality Analyser like CHK,PM20, PM30 and DMM or recorder. Input range: 200~255Vac. Output: 0~255mVdc.
PM30 Plus units. Suitable for power cables size diameter up to 50mm. Carrel & Carrel 5A ac to 10Vdc Converter
CAR,3-TRANS NZ
Three ac current to dc voltage transducers for use with 5A CTs and a
recorder or logger. Input is 0~5Aac, output is 0~10Vdc. Accuracy is 0.5%
between 1~5A at 50Hz.
Fluke 1kA ac Current Clamp
FLU,80I-1000S NZ
Three ranges: 0~10A, 0.5~100A, 5~1,000A. Jaw opening is 55mm.
HSI PSD Programable DC isolating interface
HSI,PSD NZ
Transmitter for industrial interfacing to chart recorders and loggers. Input

> NEW
LEM Current Probe 10A~1A for LEM,TOPAS 1000 PQA
LEM,CURRENT PROBE10A AU
ranges: 10mV~200V, 50µA~50mA. Bi-polar output ranges: -1V, 0~2V, 0~5V,
1~5V, 0~1mV, 0~2mV, 0~5mA, 1~5mA, 0~10mA 4~20mA. Accuracy: input/
output 0.2%.
Current Probe 10A~1A suitable for LEM Topas 1000 power quality analyser. Shimaden 4~20mA to 0~1V Isolating Interface
SHI,20/0-1 NZ
Suitable for use with chart recorders, loggers and other devices requiring
isolation from 4~20mA process signals.
Hioki 3109 ac/dc Clamp-on Current Meter
HIO,3109 AU
Current meter with recorder outputs. In dc mode is a voltage waveform.
Ranges 100, 250, 500A & 1kA. Measures to 2kA with reduced accuracy.
Voltage range 10, 25, 50, 250 & 500 ac/dc. Accuracy 2.5%FSD. Recorder
output 1V/FSD. Operates for 36h from dry batteries or via external ac.
Hioki 3285 ac/dc Clamp-on Meter with Analog Output
HIO,3285 AU
Ranges 200A/2kA ac/dc. Measure volts, ranges 30, 300 & 600V ac/dc.
Frequency ranges 10, 100Hz & 1kHz. Display LCD, counts max 2,500
current, 3,750 voltage and 1,250 frequency. Output voltage 1V for 2,000

> NEW
Cambridge Frequency Transducer 45~55Hz 240Vac
CT,891040-240 AU
count fs for each current range, can select Rec rms output, response time
about 250ms rise time, fall about 500ms. Select Mon for waveform output.
1V is produced for 1,000 count on full scale frequency range. Output not
Frequency transducer from 45~55Hz with analogue output 0~10VDC. available for voltage measurements. Supplied with signal output cord, 4mm
Powered from 240Vac only. to BNC convertor, carry case and ac adaptor. Powered with internal 9V
battery or ac adaptor.
Yokogawa 3228-11 Clip-on Ammeter
YEW,3228-11 AU
High sensitivity, 9 ranges 50mA~20A. AC or dc operation. Frequency range
40Hz~1kHz. Battery operated. Analogue output at full scale 100mV rms.
Landis & Gyr FIC-51E Voltage Transducer
LG,FIC-51E AU
AC voltage to dc voltage transducer. Max input 500V. Output voltage 1Vdc
per 100Vac input.
Tech-Rentals,M05 Instrument Transformer
TR,M05 AU
Permits monitoring of ac power lines with low input level instruments. Input
100~500V rms. Output 1~5V rms. Distortion less than 0.5%. Bandwidth
40Hz~10kHz.

62
electrical POWER
Electrical Transducers
Hioki 3128 Clamp-on Current Transducer Universal Technic P75.3C dc/ac Amp Clamp
HIO,3128 AU UNI,P75-3C AU
Clamp-on current meter with recorder output. Ranges full scale 15A~1.5kA. Max current 7,500A dc & ac peak. Bandwidth 1KHz. Min range 1kA.
Output 200mV dc full scale. Batteries not required. Output is intended only Accuracy at 75A 10% of reading. FS accuracy 2% of reading. Max bus size
for low speed recorders. 122 x 54mm or 100 x 64mm. Max cable size 83mm. Battery 9V - life 100h.
Output sockets 4mm. DC current gives dc output, ac current gives ac output,
Yokogawa 2255-01 10A ~ 5A Current Transformer 4kA range 0.5mV per amp, 7.5kA range 0.2mV per A.
YEW,2255-01 AU
Input 10Aac, output 5Aac, max circuit voltage 3.45kV, burden 15VA, accuracy Robinson 543 Linear ac Current Transducers
1% of rated value, bus bar connectors. ROB,543 AU
Wide bandwidth and very wide dynamic range. Supplied with an open
Yokogawa 2215 Current Shunt ended flexible coil of 3m length which may be wrapped around a very large
YEW,2215 AU/MY
conductor or power pole, etc. Frequency range 10Hz~10kHz with 1%
50mV output, available in range of 1A~1kA.
accuracy. Current range for 1 wrap of coil 1A~2MA at 50Hz. Phase error
Crompton 235/50 Frequency Transducer < 0.04deg. Min bending radius 60mm. External insulation is required for
CI,253/50 AU metallic conductor. Output voltage 2V rms ac waveform. Also dc rectified
Input 240V ac, 45~55Hz, output 0 ~1mA. output. In-built digital display.
Moore FDT Frequency to Volts Transducer LEM FLEXII 30, 300 & 3,000A Transducer
MOR,FDT AU LEM,LEM-FLEXII AU
Input range 6.5~12.5kHz at up to 20V peak to peak. Output 5Vdc at Flexible wrap-around ac current transducer. Length 600mm. Ranges 30,
12kHz. 300A & 3kA. Frequency response 1~20kHz. Accuracy 1%. Phase error
0.5O. Output 3Vrms @ full scale. Requires 3 units for 3ph. Designed for
Yokogawa 2261-01 2.2kV Potential Transformer multimeters and oscilloscopes (4mm banana plug or BNC connectors) but can
YEW,2261-01 AU
also be used with the DRA,808 (requires adaptor lead), or VOL,PM3000A.
3.3, 2.2kV, 440 & 220V primary to 110V secondary.
Other instruments may be attached providing the correct adaptor/transducer
Jacobs Radio CT-005 Current Transducer and connection is available. Operates for 100h from 2 x 9V batteries.
JR,CT-005 AU
Range 5kA, 2kA & 1kA. 1V dc output. Transformer can be split in two to
accommodate cable or bus 22 x 55mm.

Electrical Testers
Phase Sequence Meter 110 - 600 volts 50 / 60 Hz Biddle 550005 Turns Ratio Test Set
KYO,PSM8031 AU BID,550005 AU
KYO,8031 MY Single phase (can be used on 3ph individual phase windings). Turns ratio
Phase indicator with open phase checker and phase indicator designed to 0.001~129.999. Exciting current 0~1A. Accuracy 0.1%. Hand cranked
check the presence of open phase and also the phase sequence by rotating operation.
disk and lamps. Check a wide range of 3ph power source from 110~600V.
AVO Penta-Plus DMM Analyser
Operational voltage 110~600Vac, time limit for continuous >500V within 5min.
AVO,PENTA-PLUS-DMM AU
Frequency response 40~200Hz(ac 110~200V), 40~400Hz(ac 200~600V)
Multifunction meter for measuring 1 & 3ph volts ac, primary and secondary
safety standard IEC61010-1 CAT.III 600V pollution degree 2 withstand
current, true and reactive power, amplitude and phase angle, and also
voltage 2.2kVac for 5s. Dimensions 106L × 75W × 40Dmm, weight 350g
frequency. Easily configured to measure the amplitude and phase angle
approx. Cord 1.5m(R: red S: white T: blue)
between any 2 current or voltage inputs. Displayed simultaneously on a
backlight graphic LCD screen. Internal memory records up to 60 test results.
Logging via RS232C port. Parallel printer port. Voltage 0~650Vac, 9 ranges
with 0.1% resolution. Max 1kV. Current 0~100A ac in 11 ranges, with 0.1%
resolution. Phase angle 0~360O with 0.1O resolution. Power true and
reactive ±0-100kW & ±0~100kVAr. Frequency 45~65Hz. Timer 0~999.999.
Line or battery operated, 3h continuous on full charge.
Metrix MX120 Multicore Clamp-on Meter
MET,MX120 AU
Measures current in 1, 2, or 3 wire cables. No need to split cables or remove
covers. Ranges 2 or 3 wire 0~40A, 1 wire 0~199.9A resolution 0.1A.
Beha 5774E 3 Phase Sequence/Rotation Indicator Accuracy 5% with 2 or 3 wire oval or flat cable, 12% with round cable, 1.5%
BEH,5774E AU
with single wire. Battery operated. Display 3½ digit.
For determing the rotational direction and sequence of a 3ph supply.
Necessary to pre-determine the correct rotational direction of 3ph motors. Hioki 3282 Clamp-on Hi Tester (V, I, Hz & T)
HIO,3282 AU
Kikisui PLZ1002W Electronic Load Measures True rms, peak, min/max & hold. Ranges auto/manual, current
KIK,PLZ1002W AU/MY
30A, 300A & 1kA rms. Voltage 300/600V (1kVmax). Resistance 1/10kΩ.
Voltage range 3~110V. Current range 0~200A. In-built oscillator provides
Frequency 40~100Hz & 66Hz~1kHz. Jaw capacity 46mmØ (50mm opening).
for dynamic load testing by switching between two different load levels.
Battery life approx 1.5h continuous.
Load current may be remotely controlled by voltage or resistance signals.
Multiple units may be operated in parallel. In-built digital volt/current meter.
For dc inputs only.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 63
www.maceyselectrical.com

PCU1-SP and PCUI-LT


Primary Current Injection Systems

Features
PCU1-SP and PCU1-LT

• 5kA maximum output current


(higher overload currents for 2s)
• Multi-function digital timing system
• Digital true RMS memory ammeter
• Solid state switching
• 2000A and 5000A loading units
• Three range outputs on loading units
• Rugged, compact design
• Optional trolley mounting of system

PCU1-SP Additional Features


• Secondary injection up to 100A
• Direct reading CT ratio and polarity
electrical POWER
Electrical Testers
Hioki 3283 Clamp-on Leakage Current Tester Equimp HT2035 Electrical Tester
HIO,3283-LEAKAGE-TES AU EQU,HT2035 NZ
Analyser functions for filtering and output signals. Wide bandwidth Complies with CEI 64-8 & CEI 64-4. Eight instruments in the one case which
5Hz~15kHz, high sensitivity with a full scale of 10mA, ranges 10mA, 100mA, includes printer & RS-232C interface.
1A, 10A & 200A primary. Resolution 10µA, high accuracy at ±1%,True rms Tests are:- 1. Low Ω range 0~20Ω, resolution 0.01. 2. 2 & 3 wire earth
measurement. Output monitor and record modes, ac/dc output 1~2V full resistance measurement, range 0~1,999Ω. 3. Insulation resistance
scale. Battery 9V approx 40h. 0~199.9MΩ, 250, 500 & 1,000V. 4. RMS ac 0~500V, resolution 1. 5. Short
circuit loop impedance 0~1,999Ω, resolution 0.01. 6. Fault loop impedance
measurement 0~1,999Ω. 7. Fault loop resistance 0~1,999Ω. 8. RCD
tester.

Current Injectors
SMC PET-100-C Secondary Current Test Set T&R 200 ADM Current Injection System
SMC,PTE-100-C AU/NZ T&R,200ADM AU
AC current and voltage outputs in 4 ranges 200V/5A, 40V/25A, 20V/50A & Single phase portable current injection system with main and auxiliary ac,
10V/100A. Additional outputs ac voltage 0~220V at 1A (4A 1min), dc voltage dc current and voltage outputs. Output ranges main voltage, 10, 35, 100
0~350V at 0.7A (2.8A 1min), dc voltage 0~250V at 0.25A, fixed 110V ac at & 240Vac & 240Vdc. Main current continuous, 1~25A, intermittent up to
0.3A. Timer 1ms~99,999s. Additional functions include measurement of 200A. Auxiliaries stabilised dc isolated and protected 1.04A @ 24V~0.11A
the phase angle between the voltage and the current output tap selected, @ 220V. Variable 300mA @ 0~130Vac. Resolution 100mV, 1mA, Phase
and the measurement of the impedance of the load connected in the current 0.10. Timing range 0~999.999 with resolution 1ms. Metering LCD backlit
output taps. true rms with a memory ammeter. Interface RS232. Protection main output
duty cycle and auxiliaries, electronic thermal and fuse. Supply requirements
Multi-Amp MS-2 High Current Test Set 1ph 115~230Vac 50/60Hz 2.3kVA max.
MUL,MS-2 AU
Designed to test overload relays, circuit breakers and earth fault trip devices. T&R CIT/LU2000 Primary Current Injection Test Set
Input 240V 50/60Hz. Output continuously adjustable in 4 ranges 120V/5A, T&R,CIT AU
24V/25A, 6V/120A & 3V/240A. Short term over current of several times the Comprises control unit and 2kA loading unit (LU). Control unit includes
rated current ranges is possible. Digital current meter has read and hold timer, current and voltage meters, and variable output transformer. External
facilities for short duration currents. Digital timer measures elapsed time loading unit output 0~2kA, duty 5min on 15min off at 6V ac, continuous
between energisation and the test device operating. 0~1kA at 3V ac. Two units weight 35 & 45kg plus 2 quad 70mm2 cable sets
each 3m long. Control unit connects to LU with supplied interface cable.
> NEW T&R PCU1-SP with CT Ratio/Polarity and NLU5000A
Loading Unit
T&R,PCU1-SP NLU5000A AU
Medium powered primary current injection system. Features 5kA maximum
output current (higher overload current for 2s). Multi-function digital timing
system. Digital true RMS memory ammeter. Solid state switching. 2000A
and 5000A load units. Three range outputs on loading units. Rugged,
compact design. Optional trolley mounting of system. Secondary injection
up to 100A. Direct reading CT ratio and polarity. May be configured to either
give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V
range or 1250A on the 9.2V range.

T&R 200A-3PH/ED 3 Phase Current Injection Tester


T&R,200A3PHEDIT AU
0~200A/phase output capacity. Power supply 4 wire 5A/phase 3ph 240/415V.
Typically 10A 5 pin 3 phase socket outlet HPM.

T&R PCU1/E 2000 A Primary Current Test Set


T&R,PCU1/E AU
Comprises control unit and 2kA loading unit. Control unit includes timer,
current and voltage meters, and variable output transformer. Current output
to 100A at 5V ac, 50A at 10V ac. Voltage output to 25A at 240V ac. External
loading unit output to 30A at 240V ac. Outputs 2kA at 0~3V, 1kA at 0~6V.
Two units: weigh 35 & 45kg plus cables.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 65
electrical POWER
Power Line Conditioner/UPS
Model Type Capacity (VA)
COM,T700UPS 700
POW,700VAUPS 700
APC,1102 1,000
EAT,9120-2KVA 2,000
SB,0610-2000A 2,000
SB,0610-3000VA UPS 3,000
CHL,2200 2,200
CHL,ACTIVE2000 2,000
CHL,ACTIVE3000
3,000
APC,SU3000
CHL,5000 5,000
SB,66-102-8 2,000
Conditioner
SB,210-26-725 2,500
SB,63-25-735 3,500
HIO,BATTERYTEST Battery
SB.625-BATT Battery Pack

> NEW
Powerware 700VA/420W Line Active UPS
POW,700VAUPS AU
Compaq On-line 700 Watt UPS
COM,T700UPS NZ
Eaton Corp Powerware 9120 2kVA Online UPS
Protection in the 700~3000Va range. Input Voltage Range: 120/140/160-
EAT,9120-2KVA NZ
276 Vac. Frequency 45~65 Hz. Plug and play tower, under monitor, or 2U
The double conversion online PW9120 with its wide input voltage is capable
rackmount. Line-interactive.
of working with mains power in most conditions without discharging batteries.
Capacity 2kVA 12min IEC 10 A 5 Aust 10A 215 x 470 x 365 mm.
Sola 625 Battery Pack
SB,625-BATT NZ
Sola 625-3000VA On-line UPS
SB,625-3000VA NZ
Output regulation is ±3%, run time at full load is 8min or 20min at half load.
125% overload capacity for 10s.
Sola Basic 3500VA 110V OP Power Conditioner
SB,63-25-735 NZ
3500VA fero resonant power conditioner. 230V input and 110Vac output.
Filters out sags, surges and transients.
APC SU3000 3kVA On-line UPS
APC,SU3000 AU
Sola 66-102-8 2kVA Electronic Power Conditioner 2kVA Run time 5min at full load. Network software included. Weight 60kg.
SB,66-102-8 AU
Chloride Powerlan 2.2kVA UPS
Input voltage 240V +15% & -25%. Efficiency 94%. Distortion 0.5%.
CHL,2200 AU
Sola 210-26-725 2.5kVA Power Conditioner Sinewave output. Dual PC interfaces. Typical run time 10min. Weight 43kg.
SB,210-26-725 AU Vigilant 7 network interfacing software included.
Input range 240V ±40% for +5% & -8% regulation. Max distortion on linear
Chloride Powerlan 5kVA UPS
loads 3%, on typical computer loads 5%. Efficiency 90%.
CHL,5000 AU
Sola 0601-2000A 2kVA On-line UPS Sinewave output. Dual PC interfaces. Typical run time 10min. Weight
SB,0610-2000A AU 120kg. Vigilant 7 network interfacing software included.
SB,0610-2000VA NZ
Chloride Active 2kVA Double Conversion UPS
Run time 10min or 25min at half load. Novell/RS232 communications
CHL,ACTIVE2000 AU
interface included providing relay contacts for mains failure and low
Double conversion sinewave output. Dual PC interfaces. Typical run time
battery, input for remote shut down, and RS232 send/receive, all via a DB9
20min. Input (nominal) 2220/230/240V ac 1ph + N. Output 220/230/240V
connector.
ac 1ph + N ±3%. Efficiency >88%. Dimensions 200w x 875d x 350hmm.
APC Pro 1000 UPS Weight 81kg. MopUPS Professional software for system monitoring and
APC,1102 NZ shutdown included. USB port & RS232 communication port for UPS
1 KVA line interactive ups with built-in filters for sags, surges and transients. monitoring and management.
Switches to battery power in 20ms in the event of a power outage.

66
electrical POWER
Power Line Conditioner/UPS
Chloride Active 3kVA UPS Hioki Battery HiTester
CHL,ACTIVE3000 AU HIO,3551BATTERYTEST AU
Double conversion sinewave output. Dual PC interfaces. Typical run time Takes on-the-spot measurements of the internal resistance, voltage
20min. Input (nominal) 2220/230/240V ac 1ph + N. Output 220/230/240V and temperature of lead-acid batteries, principally for UPS and similar
ac 1ph + N ±3%. Efficiency >90%. Dimensions 200w x 875d x 350hmm. applications, without needing to shut off the battery. Instantaneous results,
Weight 81kg. MopUPS Professional software for system monitoring and on a three-rank scale of Pass, Warning, or Fail, using a composite decision
shutdown included. USB port & RS232 communication port for UPS based on the internal resistance and the voltage. Resolution of 1µΩ,
monitoring and management. necessary for high capacity batteries (of at least 500Ah). Includes Hioki
9460 clip type temperature leads.

Power Transformers
Model Type Phases VA Output (VAC)
FER,115-2000 Power Transformer 2,000
1 115
FER,115-1000 1,000
VAR,D-283-OB Auto Transformer 3 16,000 0~470
VAR,2000 2000
0~260
VAR,3000 Variac 3,000
VAR,16000-3 20A/Ph
3 0~470 Ph-Ph
VAR,6500-3 8A/Ph

> NEW Dimmer Dot Variable AC Voltage Auto Transformer 3


Phase 23~28A
VAR,D-283-OB AU
Variac 2kVA 0~260Vac Output
VAR,2000 AU
Variac 3kVA 0~260Vac Output
Manual operated air cooled; Input 400/415V, 50Hz. Output 0~415/470V.
VAR,3000 AU/MY
23-28A. Total Weight 95kgs.
Variac 16kVa-3 3ph 20A
Ferguson 115-2000 2kVA 240/115V Transformer VAR,16000-3 AU
FER,115-2000 AU
Variac 6500-3 3ph 6.5kVA
Ferguson 115-1,000 240V 1kW Transformer VAR,6500-3 AU/NZ
FER,115-1000 AU
Variac 3ph 6.5kVA. 0~470Vac output for 415Vac input, max current 8A/ph.
240~115Vac, 1kVA stepdown transformer.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 67
electrical POWER
AC Sources/Inverters/Generators
Model Type VA Output (VAC)
ELG,501
AC Power Amp 0~270
BEH,BL1350C-2
RED,DA3179 Motor generator 12 V 400 240
PC,250I Sine Wave Inverter 12 V 250 250
PC,300I-24 Power Inverter 24 V
300
PC,300I-12 Power Inverter 12 V
240
HON,EU3000is Petrol Generator 3000
YAM,EF3000iSE Petrol Generator/Inverter Set 3000
TRA,230-115 Transformer 1000 115

Elgar 501 ac Power Source Power Conversions 250I Inverter


ELG,501 AU PC,250I AU
AC power amplifier. Operates from 240V 1ph ac. Output ranges on tapped 250W sine wave inverter. 12Vdc input.
transformer 0~65, 0~130, 0~260Vac. Output power 500VA. Alternative
Power Inverter 300W 24Vdc Output 240V
oscillators available for 10Hz~10kHz operation. Amplifier output rated over
PC,300I-24 AU
45Hz~5kHz. Two units may be connected for 1kVA output. Three units may
Sinewave inverter. Output Power continuous (peak) 300W (1kW). Frequency
be used with a single 403 oscillator to give a 3ph output at 1.5kVA.
50Hz ±1%.
Behlman BL1350C-2 1350 VA Power Amplifier 230 to 115 VAC Transformer 1 kVA
BEH,BL1350C-2 AU
TRA,230-115 NZ
AC power amplifier with oscillator. Max power output 1.35kVA. Max current
Maximum power is 1kW. USA power socket.
10A on 0~135V range, 5A on 0~270V range. Output frequency 45~500Hz.
External frequency synchronising input. Remote 0~10Vdc programming Ebbett 1,5kW DC to AC Inverter
of output frequency and voltage. Digital true rms readout of voltage and EBB,12/1500 NZ
current. Units may be stacked for higher power or 2 & 3 phase operation. 12Vdc~240Vac 50Hz sinewave inverter. Continuous rating 1,000VA.
Intermittent use 1,500VA. Surge (motor start) 2,000VA. Overload protected
Honda EU3000is Generator 240V/3kVA Inverter Output with automatic soft start. Output 230Vac ±5%. Frequency 50Hz ±0.5.
HON,EU3000IS AU
Three pin outlet socket.
3kVA /240Vac generator inverter type. Working on Petrol.
Yamaha EF3000iSE 3kVA Petrol Generator/Inverter Set
YAM,EF3KISE AU
Output ac 3kVA 2.8kW @ 240V 50Hz, max harmonic distortion 2.5% (mains
supply can exceed 5%), 12Vdc @ 14A. Sound attenuated enclosure (level
57dB(A) @ 7m) with 4 wheels. Dimensions 680w x 445d x 555hmm. Dry
weight 70kg. Engine 4 stroke, air cooled ohv, fuel tank 13L (unleaded),
duration at 25% load 20h with auto throttle on. Electric and pull start.

Rediline DA3179 12/240V dc-ac Inverter


RED,DA3179 AU/MY
Motor generator. 12Vdc to 240Vac sinewave output. Continuous rating
400W. Intermittent use 600W. Lower duty cycle 50% on, 25% off, 1.2kW,
auto starts on load. Overload protected. Weight 12kg. Overall frequency
regulation 47~53Hz.

68
DATA ACQUISITION & RECORDING
Data Loggers
Digital Digital
Analogue in dc Voltage Strain Sample Flashcard
Data Loggers in out RTD TC Comms Memory
(Ch) supply Ranges Gauge Rate (Hz) MB
(Ch) (Ch)
DE,DT605 10 13.65k
5 5 25mV~100V RS232 1 SRAM 1
DE,DT605-3 (30 unbal) 166.538k
Yes Yes
DE,DT800 12 10BaseT/ 64M
16 8 10mV~10V 100kHz 64
DE,DT800-4PRO (42 unbal) RS232 64M
Yes Yes
HIO,8421-01
16 Yes 8Mb 256
HIO,8421-51 100mV~60V No LAN
HIO,8422-51 32 No 8Mb 512
YEW,DA100-40CH 40 20mV~50V Yes RS232 0.5
FOU,DAQPRO 0~50mV Yes
8 Yes No USB 512kB 0~10kHz
FOU,DAQPRO-2 0~10V J,K

TIN,TGPR-0804 4~20mA RS232 15.9k 1s No


Comms
TIN,TGPR-0704-10VDC 1 0~10V dc No No RS232C
TIN,TGPR-0704-2.5V 0~2.5V RS232C

Memory Recorders for transient Analogue in Digital in Chart Paper Chart Speed Memory Sample
FDD Voltage Ranges RS232
& continued signals (channels) (channels) (mm) (mm/s) per ch Rate

HIO,8835 100kW
4 100
HIO,8835-01 1Megaword
16 9 Yes 100mV ~400V No 1MHz
HIO,8841 8 200 1M
HIO,8842 16 200 2M
HIO,8860 8 16 200 20 No No Var
YEW,ORM1300 16
Yes 128k
YEW,ORM1200 200 100 100mV ~500V 100kHz
YEW,ORP1200 8 3k
YEW,DL708E 100 Yes 50mV ~800V 1M Yes 10MHz

Chart
Analogue in dc Voltage Ranges Sample Rate
Hybrid & Pen Recorders Paper Chart Speed FDD TC RTD RS232
(Ch) Supply (V) (Hz)
(mm)
YEW,3057-22 2 150 10mm/s 10mV – 50
YEW,3712-31 3 250 Yes
1,200mm/min 10mV – 200 135
YEW,3712-41 4 250
YEW,3750 10
150 Yes
YEW,3750-DC 20 Yes Yes
20mV – 50 0.5 Yes
YEW,3760 30 250 1,500mm/h

YEW,DR130 20 150 Yes

70
DATA ACQUISITION & RECORDING
Data Loggers
Fourier DAQPRO 8 Channel Data Logger Datataker DT800 Data Logger with Delogger 4Pro & Transit
FOU,DAQPRO AU/NZ Case
Portable, hand held, battery operated 8 channel data logger. 16-bit DE,DT800-4PRO AU
resolution, built in graphic LCD, for setting up, graphical display of logged Universal input channels 12 balanced or 42 unbalanced analog channels. Eight
data. PC communications via USB interface. Signal inputs 0-24mA, 0- bi-directional digital channels & 8 digital input channels. Solid state multiplexer
50mV, 0-10V. Temperature input via NTC 10kOHM, 100kOHM, range - protected to ±40V. Max in/out voltage ±12V. Serial sensor channel can be
25~150OC, PT100 range -200~400OC, T/C ranges J type, -300~1500OC, used with GPS systems. Measures V, 4~20mA, strain, TC, RTD etc. Sampling
K type -250~1100OC, T type -200~400OC. Frequency input one channel rate 200Hz up to 100kHz in burst mode. Instrument has RS232, RS422, USB,
only, 20~4000Hz, sensitivity 20mV, pulse counter one input 0~65000 ethernet (10baseT) and PC card modem communications. Plugable 64Mb
counts. Memory capacity 512KB, sampling rates from 1S/Hr to 4,000S/sec. memory card stores up to 300,000 (compressed) readings per Mb. Instrument
Supplied with analysis and setting up software. stores 600,000 (compressed) readings in internal memory. Total memory
capacity 10.2Mb (compressed). Supplied with Delogger 4Pro & IP67 PE-800
portable enclosure with mounting frame.

DataTaker DT605 Data Logger


DE,DT605 NZ
Fourier DAQPRO8 Batter Operated hand held 8 Channel Data
Logger Input capacity 100V. LCD display enabling use as a measuring instrument if
FOU,DAQPRO-2 AU preprogrammed for channel parameters. Ten differential or 30 single ended
Portable, hand held, battery operated 8 channel data logger. 16-bit channels. Channels/sec 25. Digital inputs 4TTL/CMOS. Three counter channels
resolution, built in graphic LCD, for setting up, graphical display of logged up to 1MHz. Up to 120 alarms with 1 digital I/O and 3 front panel LED’s. Internal
data. PC communications via USB interface. Signal inputs 0-24mA, 0- memory up to 11,000 readings. Optional memory card to 170,000 readings.
50mV, 0-10V. Temperature input via NTC 10kOHM, 100kOHM, range - RS232C data communications port and RS485 port for networking up to 32
25~150OC, PT100 range -200~400OC, T/C ranges J type, -300~1500OC, loggers. Maths processing included. Inputs voltage 25mV~2.5Vdc & 100Vdc.
K type -250~1100OC, T type -200~400OC. Frequency input one channel Max sensitivity 2µV. Current 0.25~25mA. Current loop 4~20 mA. Resistance up
only, 20~4000Hz, sensitivity 20mV, pulse counter one input 0~65000 to 7kΩ. Thermocouples B, C, D, E, G, J, K, N, R, S and T from -250~1,800OC.
counts. Memory capacity 512KB, sampling rates from 1S/Hr to 4,000S/sec. Thermistors and RTD’s. Strain gauges. Supplied with Determinal and Delogger
Supplied with analysis and setting up software. software. Operates from internal battery, external battery or ac mains.

DataTaker 1Mb PCMCIA Card for DT Series 2 Data Taker DT605-3 Series 3 Data Logger
DE,DT605-3 AU
DE,DT-MEM1024 AU
Memory card for DataTaker DT600 series loggers. Capacity 1.024Mb. Input capacity 100V and built in SRAM Card Slot. LCD display enabling
use as a measuring instrument if pre-programmed for channel parameters.
DataTaker DT500/600 Expansion Module Ten differential or 30 single ended channels. Channels/sec 25. Digital
DE,CEM-AD AU inputs 4TTL/CMOS. Three counter channels up to 1MHz. Up to 120 alarms
Channel expansion module for DT500 & DT600 data loggers. Adds with 1 digital I/O and 3 front panel LED’s. Internal memory up to 166,530
10 differential analogue and 20 digital state inputs. Also adds 10 digital readings. Optional 1Mb memory card to 343,980 readings. RS232C data
outputs. communications port and RS485 port for networking up to 32 loggers. Maths
DataTaker DT5LTP-R One Channel Logger processing included. Inputs V 25mV~2.5Vdc & 100Vdc. Max sensitivity
DE,DT5LTP-R AU 2µV. Current 0.25~25mA. Current loop 4~20mA. Resistance up to 7kΩ.
One channel platinum resistance probe temperature logger. Range Thermocouples B, C, D, E, G, J, K, N, R, S and T from -250~1,800OC.
-50~50OC up to 0.1 resolution, -50~250OC up to 0.3 resolution. Memory Thermistors and RTD’s. Strain gauges. Supplied with Determinal and
store up to 4,048 readings. External probe. Lithium battery. Delogger software. Operates from internal battery, external battery or ac
mains.
DataTaker DT800 Data Logger
DE,DT800 AU/NZ
Universal input channels 12 balanced or 42 unbalanced analog channels.
Eight bi-directional digital channels & 8 digital input channels. Solid state
multiplexer protected to ±40V. Max in/out voltage ±12V. Serial sensor
channel can be used with GPS systems. Measures V, 4~20mA, strain, TC,
RTD etc. Sampling rate 200Hz up to 100kHz in burst mode. Instrument has
RS232, RS422, USB, Ethernet (10baseT) & PC card modem communications.
Plugable 64Mb memory card stores up to 300,000 (compressed) readings
per Mb. Instrument stores 600,000 (compressed) readings in internal
memory. Total memory capacity 10.2Mb (compressed).

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 71
DATA ACQUISITION & RECORDING
Data Loggers
Hioki 8421-01 16 Channel Data Logger with Colour Display Yokogawa 2423A Six Channel Logger
HIO,8421-01 AU YEW,2423A17 NZ
Sixteen analogue, 4 pulse input channels data logger with colour display, Portable voltage and thermometer logger. Ranges are 10, 1 & 0.1V. Type
PCMCIA card slot, LAN interface built in, TCP/IP communication supports K, E, J, T, R, S, B, L, U thermocouples. Memory stores 14,000 data points.
real time PC logging, FTP, SMTP and HTTP. Signal inputs 100mVdc, 1Vdc, Min logging interval is 10s. Large LCD display, analogue and RS232 output.
10Vdc, 60Vdc, 1~5Vdc fs. Thermocouples K,E, J, T, N, W (WRe5~26) R, Supplied with software for uploading data to CSV or TXT format.
S, B, -100~100OC, -200~500OC, -200~2,000OC, RTD Pt100 -200~800OC.
Pulse input, accumulation 50,000 counts fs, 500,000 counts fs, 5M counts
fs, 100M counts fs, 2,500M counts fs. Rotation 5,000/n (r/s) fs. Recording
> NEW Hioki 3632-20 Temperature Logger with Internal
Sensor Only
HIO,3632-20 AU
interval is selectable from 100, 200, 500ms, 1, 2, 5, 10, 20, 30s, 1, 2 &
Temperature logger (1 channel) includes 1 x RS232C & 1 x USB
5min. Max sampling rate is dependent upon type of input signal. Internal
communication base, utility software, RS232C and USB interface cables.
Memory 8Mb, 256Mb Flashcard, 9334 logger communicator software, 9642
Temperature range -20~+70ºC. Accuracy -20~-0.1ºC +/-1.0ºC. 0~35ºC +/-
LAN cable, 9641 pulse signal input cable all supplied.
0.5ºC, 35.1~70ºC +/-1.0ºC. Internal thermistor sensor, water resilience IP67.
Hioki 8421-51 16 Channel Data Logger with Colour Display Built in LCD.
HIO,8421-51 au
Sixteen Analogue, 4 pulse input channels data logger with colour display,
PCMCIA card slot, LAN interface built in, TCP/IP communication supports
real time PC logging, FTP, SMTP and HTTP. Signal inputs- 100 mVdc, 1Vdc,
10 Vdc, 60Vdc, 1-5Vdc f.s. Thermocouples K,E, J, T, N, W (WRe5-26) R,
S, B, -100~100OC, -200~500OC, -200~2000OC, RTD Pt100 -200~800OC.
Pulse input, accumulation 50,000C f.s, 500,000C f.s, 5MC f.s, 100MC f.s,
2,500MC f.s. Rotation 5,000/n (r/s) f.s. Recording interval selectable from
100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min, 2min, 5min. Max
sampling rate is dependent upon type of input signal. Internal Memory 16MW,
512MB PCMCIA FLASH card, 9334 Logger Communicator software, 9642
LAN cable, 9641 pulse signal input cable all supplied. Improved common
mode rejection- 100dB or better when 50/60Hz, 140dB or better when 50Hz,
using ch1 to ch16, interval 5s, digital filter 50Hz selected. Faster sampling
when using Pt100, improved temperature characteristics.
Hioki 3641-20 Temperature/Humidity Logger with RS-232C &
Hioki 8422-51 32 Channel Data Logger Logger USB
HIO,8422-51 AU
HIO,3641-20 AU/MY
Thirty two analogue, 4 pulse input channels data logger with colour display,
Includes 1 x RS232C & 1 x USB communication base, utility software,
PCMCIA card slot, LAN interface built in, TCP/IP communication supports
RS232C & USB interface cables. Temperature range -40~85OC, humidity
real time PC logging, FTP, SMTP and HTTP. Signal inputs: 100mV, 1, 10 &
range 0%~100%RH. Accuracy temperature -40~-0.1OC ±1, 0~35OC ±0.5,
60Vdc, 1~5Vdc fs. Thermocouples K,E, J, T, N, W (WRe5-26) R, S, B, -100
35.1~70OC ±1 & 70.1~85OC ±2. Humidity typical between ±5~±10%RH
~100OC, -200~500OC, -200~2,000OC. Pulse input, accumulation 50,000
depends on temperature and humidity range.
counts fs, 500,000 counts fs, 5M counts fs, 100M counts fs & 2,500M counts
fs. Rotation 5,000/n (r/s) fs. Recording interval is selectable from 100, 200, Hioki 3641-20-Kit of 8 Temperature & Humidity Loggers
500ms, 1, 2, 5, 10, 20, 30s, 1, 2 & 5min. Max sampling rate is dependent HIO,3641-20-KIT AU
upon type of input signal. Internal Memory 8Mb, 512Mb PCMCIA FLASH Kit of 8 x temperature and humidity loggers. Includes 1 x RS232C and 1
card, 9334 Logger Communicator software, 9642 LAN cable, 9641 pulse x USB communication base, utility software, RS232C and USB interface
signal input cable all supplied. cables. Temperature range -40OC~85OC, humidity range 0.0%RH to 100%
RH. Accuracy: Temperature -40~-0.1OC +/- 1.0OC , 0.0~35OC +/- 0.5OC,
35.1~70OC +/- 1OC, 70.1~85OC +/- 2OC. Humidity typical between +/-5 to
+/-10% depends on temperature and humidity range. 8000 data points X 2
channels, recording interval 2,5,10,15,20,30 sec,1,2,5,10,15 ,20,30,60 min.

Fourier Microlog Temp/Hum Logger Kit with Wireless Cradles


FOU,MICROLOG-KIT AU
Set of 5 temperature and humidity loggers mounted in RF transmitter
cradles, one receiver for PC. Transmission range up to 300m or RS232C
Yokogawa MV200 Twenty Channel Logger & USB interface also included if direct connection to PC for down loading
YEW,MV200 NZ
required. Temperature range -30~50OC, accuracy ±1O, 0~100%RH
Twenty channel voltage, RTD and thermocouple logger. Color LCD display
accuracy ±3%RH, 2 digit LCD, memory capacity 16,000 data points
10.4” TFT, removable PCMCIA ATA flash memory card. Supports data
between 2 channels. User defined sampling rate from 10s~2h. MicroLog
collection over ethernet networks. Supplied with RJ-45 cable and standard
Plus management control software included to control and monitor all the
software.
loggers remotely on PC within transmission range.
Yokogawa Data Logger for PC Acquisition Escort Temperature Humidity Logger Set of 10
YEW,DA100-40CH AU
ESC,HUM/T-KIT AU
PC based datalogger with dc supply. Channels 40, 50V max input 0.05%
ESC,HUM-KIT NZ
basic accuracy. Accepts RTD and TC inputs. Must be used in conjunction
Includes software and communication base for down loading of data from
with a PC includes analysis software. Scan rate 2s.
loggers to a PC. Data presented in table or graph form. Max sample rate
1min.

72
DATA ACQUISITION & RECORDING
Data Loggers
Escort Analogue Adaptor Tiny Tag One Channel 0~20mA Current Input Logger
ESC,ANALOGUE NZ TIN,TGPR-0804 AU
Analogue adaptor for dc voltage and dc current inputs. Inputs: 0~20mA, 0~2 Logger 4~20mA single channel. Readings 15,900. Re-scalable IP68 78w x
VDC, 0~10Vdc. 50d x 34hmm. Two level alarm leds. Accuracy 0.6% 0.1mA.
Escort Four Channel Temperature Logger Tiny Tag TGPR~0704~10Vdc Data Logger
ESC,4 EXT NZ TIN,TGPR-0704-10VDC AU
Range -20~60OC. Resolution 0.3OC. Accuracy 0.5OC. Stores 30,000 Single channel 0~10Vdc logger , 8 bit A to D resolution. Stores 15,900
readings. Supplied with software, interface and 3m long temperature readings. 2 alarms with red indicator LED. Reading interval from 1s~10d.
sensors. Range: 0~10Vdc, max input 14V, accuracy ±40mV, ±1% rdg, 400kΩ
impedance. Battery operated.
Escort Three Channel Low Temperature Logger
ESC,3EXT-LO/SS NZ Tiny Tag TGPR~0704~2.5Vdc Data Logger
Range -40~40ºC, accuracy 0.5ºC, resolution 0.3ºC. Supplied with 3 TIN,TGPR-0704-2.5V AU
temperature sensors and software. Single channel 0~2.5V logger, 8 bit A to D resolution. Stores 15,900
readings. 2 alarms with red indicator LED. Reading interval from 1s~10d.
Escort Internal Temperature Logger Range 0~2.5V range, max input 3.5V, accuracy ±10mV. Battery operated.
ESC,INT-LO NZ
Single channel low temperature logger. Range -40~40ºC, resolution is 0.5ºC, Testo 177-H1 Logger with Display
accuracy is 0.3ºC. Can be immersed in liquid. Stores 24,000 readings. TES,177-H1 MY
Supplied with software and serial interface for uploading data. Parameters: Humidity/Temp/Dew Point. Sensors: Humidity Sensor/
NTC(internal). No of Channels: 4 CH. Measuring Range: 0~100%RH &
Escort pH Adaptor -20~+70 celcius(internal). Memory: 48,000 readings.
ESC,PH-ADAPTOR NZ
Glass electrode type pH adaptor probe. Range 0~14pH, resolution 0.015pH. Testo 177-T4 Logger with Display
User calibration via offset and slope adjustment screws. Supplied with 10m TES,177-T4 MY
temperature compensation probe. WARNING!! Do not use the electrode in Parameters: Temperature(C/F). Sensors: Thermocouple Type-K. No of
perchlorate, silver, sulphide or any hydrofluoric solutions containing more Channels: 4 CH(external). Measuring Range: -100~+1000 celcius(external).
than 1M acid or base, or at temperatures more than 50ºC. Use at high Memory: 48,000 readings
temperatures may shorten the life of the electrode.
Escort Autoclave Logger
ESC,AUTOCLAVE NZ
Temperature logger suitable for use in autoclave sterilizers. Temperature
range is 25~150ºC, resolution: 0.5ºC, accuracy: ±0.5ºC. Rated to 150ºC
for 30min or 125ºC for indefinite. Maximum of 60min endurance for dry
heat oven @ 150ºC. Stainless steel body with 1 external sensor, stores
2000 readings in its memory. IP68 rated to 5bar. Supplied with calibration
certificate, software and serial interface for programing & uploading.

Instrumentation Amplifiers
Vishay 2100 Eight Channel Instrument Amplifier
VIS,2100 AU
Eight channel signal conditioner/amplifier system comprising 4 dual amplifiers with power supply, digital output display and rack frame. Accepts low level
signals and conditions and amplifies them to drive recorders. Bridge balancing for quarter (120 & 350Ω), half & full bridge (50~1kΩ). Quarter bridge dummy
resistors provided. Gain 100~2100. Bandwidth dc ~5kHz at 0.5dB, 13kHz at 3dB. Output ±10V @ 30mA, 50mA into 150Ω, 100 mA into 15Ω. Type 2130
digital readout can be switched to each output in turn and also to an external source. Ranges ±1,999mV & 19,999mV.

Memory Recorders
Yokogawa ORP1200 8 Channel Memory Recorders Yokogawa ORM1200 8 Channel Memory Recorders
YEW,ORP1200 AU/MY YEW,ORM1200 AU
In-built waveform display. Input ranges 100mV~500V. Max input voltage Similar to YEW,ORP1200 except it has 128K RAM per channel (ie. 512K
is 500V peak or 350V rms ac. Memory 32k per channel, may be combined when used as a 2 channel recorder) includes FDD.
for 2 channel 128k operation. Memory may be divided into 16 blocks of
Yokogawa DL708 8 Channel Recorder/Digital Scope
2k. 128k memory at 1kHz sampling (20 points of 50Hz cycle) gives 128s
YEW,DL708E MY
storage. Real time recording 10mm/hr~100mm/s. Real time recorder with
Eight channels 10M/s sampling 10 bit 8M word of memory, 1.2Gb HDD
memory trigger facility. 4 triggers including high, low, rise, fall, with and/or
(100k/s sampling continuously to disk). In-built printer, FDD, RS232, GPIB
facility. X-Y operation with up to 4 channels. Memory card facility for storing
and VGA. Input ranges 5mV/div~200V/div . 800V isolated input capability
memory dumps and setups. Memory card not included.
(using x10 probes). Input filters, FFT, color display, measurement of 26
Yokogawa ORM1300 16 Analogue Channel Memory Recorders waveform parameters. Simple and advanced trigger including a window
YEW,ORM1300 AU trigger.
Similar to YEW,ORM1200 except it has 16 analog channels rather than 8.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 73
DATA ACQUISITION & RECORDING
Memory Recorders

> NEW
Hioki 8860 8 Channel High Speed Memory Recorder
HIO,8860 AU
Hioki 8811 3 Analogue 8 Digital Channel Memory Recorders
HIO,8811 AU/MY
Four functions, memory X-T, continuous X-T, memory X-Y & continuous X-Y.
High speed memory recorder, 20MS/s sampling rate, 8 analog channels, 16 Three channel X-Y is possible. Input amplifier bandwidth 0~100kHz limited
logic channels, built in printer. 512MW or direct access memory, 60GB hard by max sampling rate of 4µs in memory mode and 100~200µs in continuous
drive built-in, PC card type II slot up to 4GB ATA flash card (optional) USB, mode. Memory size per channel 8k with 8 bit resolution. Paper 110mm
LAN interface and large colour screen. x 30m. Full scale 90mm in 10 divisions. Time axis up to 160 divisions in
memory mode giving 32ms~1,600s display. Continuous mode chart speed
1s~50min/div in 12 steps. Input floating 10mV~5V/div in 12 steps with
full scale offset. Internal trigger with level control. External trigger TTL or
contact closure. Successive transient recording possible. Multiple recorder
synchronization possible. Hioki 9306 and 9307 probes optional.
Hioki 8835 4 Channel Waveform & 16 Channel Memory
Recorder
HIO,8835 AU
Memory 12 bits x 100k per channel or 500k for a single channel. Analog
input channel ranges 10mV~50V/div, 10X div, 400Vdc, 240Vac rms max.
In-built FDD and type-III PC card slot. Fastest sampling rate 1MHz. Paper
110mm x 30m. Colour TFT display. Additional functions include waveform
parameter calculation including rms values, area value, rise and fall times.
AC mains operation.
Hioki 8835-01 4 Analogue, 16 Logic Channel Waveform
Recorder
HIO,8835-01 AU
Memory 12 bits x 1 megaword per channel or 4 megaword for a single

> NEW
Hioki 9725 Memory Viewer Software
HIO,9725 AU
channel. Analog input channel ranges 10mV~50V/div, 10X div, 400Vdc,
240Vac rms max. In-built FDD & type-III PC card slot. Fastest sampling
rate 1MHz. Paper 110mm x 30m. Colour TFT display. Additional functions
Data processing software for Hioki 8860 High Speed Memory Recorder. include waveform parameter calculation including rms values, area value,
Functions: file loading, maximum loadable data size 2GW file saving, rise and fall times. AC mains operation. Logic probes must be rented
measurement of data binary, partial saving between A/B cursors is possible. seperately.
Screen images BMP and PNG, calculation results. Display of saved
binary files, displayable channels per sheet analog 32, logic 16 channels.
Displayable sheets 16.

> NEW
Hioki 8938 FFT Input Signal Module
HIO,8938 AU
FFT Module with anti-aliasing filter. Frequency range dc to 400kHz, sampling
rate 1MS/s. Maximum input voltage 400Vdc, 240Vrms.

Hioki 8841 8 Analogue, 16 Channel Memory Recorder


HIO,8841 AU/NZ
Memory 12 bits x 4 megawords/ch for 2 analog ch, to 1 megawords/ch for
8ch. In-built FDD, type III PCMCIA card slot (for flashcard & HDD up to
520Mb). Sampling rate of 1MHz max. Functions memory, real time record,
Hioki 8810 4 Channel Memory Recorders rms, real time/memory, X-Y memory, FFT. Trigger functions level, window
HIO,8810 AU
in, window out, voltage drop, rms level, cycle, logic pattern trigger 1,0 or
4 functions: memory X-T, continuous X-T, memory X-Y, continuous X-Y. 3
x (disregard). When using logic channels, logic probes must be rented
channel X-Y is possible. Input amplifier bandwidth 0~100 kHz limited by
seperately. Measurement range 400Vdc, 240V rms, low pass filters 5Hz,
max sampling rate of 4µs in memory mode and 100~200µs in continuous
500Hz, 5kHz or 100kHz, input coupling dc, GND, ac. Large 10.4” colour
modes. Memory size per channel 8k with 8 bit resolution. Paper 110mm
TFT display for settings and waveform display, wide thermal printer fitted.
x 30m. Full scale 90mm in 10 divisions. Time axis up to 160 divisions in
On screen help function. All settings and waveforms can be saved to media,
memory mode giving 32ms~1,600s display. Continuous mode chart speed
waveforms can be saved as binary, text or bmp files.
1s/div~50min/div in 12 steps. Input floating 10mV/div~5V/div in 12 steps
with fs offset. Internal trigger with level control. External trigger TTL or
contact closure. Successive transient recording possible. Multiple recorder
synchronization possible.

74
DATA ACQUISITION & RECORDING
Memory Recorders
Hioki 8842 16 Analogue, 16 Logic Channel Waveform Recorder Hioki 9321 Line Logic Probe
HIO,8842 AU HIO,9321 AU
Memory 12 bits x 16 megawords/ch for 2 analogue ch, to 2 megawords/ch Four channels (insulated) per probe. Detection of 60~150Vac, 170~250Vac,
for 16 ch. Analogue input channel ranges 10mV~50V per div, 10X div, 400V 20~150Vdc & 70~250Vdc in 2 ranges. Response time slope rise 1ms, fall
dc, 240V ac rms max. In-built FDD, type III PCMCIA card slot (for flashcard 3ms. Max input low range 150V rms, high range 250V rms. Max rated
& HDD up to 520Mb). Sampling rate of 1MHz max. Functions memory, real voltage to earth 250V rms. Connector cable 1.5m. Probe tip cable 1m.
time record, rms, real time/memory, X-Y memory. Trigger functions level,
window in, window out, voltage drop, rms level, cycle, logic pattern trigger
1,0 or x (disregard). When using logic channels, logic probes must be rented
seperately. Measurement range 400V dc, 240V rms, low pass filters 5Hz,
500Hz, 5kHz, or 100kHz, input coupling dc, GND, ac. Large 10.4” colour
TFT display for settings and waveform display, wide thermal printer fitted.
On screen help function. All settings and waveforms can be saved to media,
waveforms can be saved as binary, text or bmp files.

Hioki Kit of Three 9322 High Voltage True rms Interface


HIO,9322-KIT AU
Used with many memory recorders, eg. Hioki 8835. Operating modes 3. DC
mode for waveform monitor output dc to 3MHz, ac mode detection of power
surge noise 1 kHz~10MHz. Rectified true rms output of dc & ac voltages.
40Hz~100kHz response speed 200ms or less. Max voltage dc 2kV, ac 1kV
CATII, ac/dc 600V CATIII, balanced differential input 1/1,000 divider.
Hioki 520Mb PCMCIA Hard Disk for HIO,8835 & 8841
HIO,8835-HD520 AU
Hioki 9335 Wave Process Software
Data can be stored as mem file which is binary, data can be replayed on
HIO,9935 AU
recorder, txt file which is text so as data can be read using excel, bmp file so
Waveform Processor software, displays, converts to CSV, calculates and
screen dump can be saved for import to word document, single or dual FFT
prints waveforms with a PC. Review stored binary files from Hioki 8835,
binary file for playback on recorder. File can be saved as setting file, useful
8835-01, 8841 and 8842 memory recorders. Only way stored binary files
for customers who rent the memory recorder for same applications again.
can be viewed on a PC without having to re save them with memory recorder
Transfer files to a PC and reload next time recorder is rented, saves time
as Text files.
in use of recorders. Card can be plugged in to a PCMCIA Type III slot on a
Hioki 9305 Trigger Cord for Hioki Memory Recorders laptop, files can be stored or viewed.
HIO,9305 AU
Plug each end of cable 3.5mm. Trigger cord enables master slaving of the
Hioki 9555 Current Sensor
HIO,9555 AU
Hioki 8835, 8810 and 8811 memory recorders. One end connected to the
For HIO,9278 clamp on CT. Output designed for waveform recording and
trigger output socket of master recorder the other end connects to the trigger
depends on CT.
input socket of the second recorder which is the slave. Trigger pattern set up
for the master and the slave recorder set just to external trigger. Sandisk Compact Flash Card 512MB with PCMCIA Adaptor
COM,FLASH512MB AU
Hioki 4 Channel Digital Probe for use with HIO,8835
Compact Flash Card 512MB typeI with PCMCIA Adaptor.
HIO,9306 AU
Contact interface for HIO, 8811, 8835, 8835-01, 8841 & 8842 memory Hioki 9278 Universal Clamp-on CT
recorders. Threshold digital >1.4V maximum input 50V. Contact closure HIO,9278 AU
input, 2kΩ input resistance 30V allowable input. Response time 2µs. For use with HIO,9555. Range 0~200A, dc 100kHz, 20mmØ max jaw.
Hioki 9320 4 Channel Contact & Digital Logic Probe Hioki 9132 Clip-on ac Current Transducer
HIO,9320 AU HIO,9132 AU/NZ
For HIO, 8811, 8835, 8835-01, 8841 & 8842 memory recorders, 4 channels Ranges 20~1kA fs. Short term overload capability 2kA. Output 0.2Vac. For
per probe, max of 4 probes per recorder. Use in conjunction with 9321 line use with Hioki 8800 series recorders, for current waveform recording.
logic probe. Threshold digital selectable 1.4V, 2.5V & 4V. Response time
500ns max. Relay dry contact detection. Max allowable input 50Vdc.
Hioki 9018-10 500A ac Clamp-On Transducer
HIO,9018-10 AU
Selectable ranges 10~500A. Output voltage 200mVac fs per range selected.
Up to 3kHz frequency response. BNC connection.
Hioki 3270 Sensor with 150A ac/dc Clamp-On Transducer
HIO,3270-9276 AU
Frequency bandwidth dc to 1MHz, rated output 1.5V for fs of range. Clamp
20mmØ. Suitable to view waveforms with memory recorders.
Hioki 9555 Signal Conditioner with 9278 200A ac/dc Clamp-On
Transducer
HIO,9555-9278 AU
Frequency bandwidth dc to 100kHz, rated output 2V for fs of range. Clamp
20mmØ. Suitable to view waveforms with memory recorders.
Hioki 9304 Input Attenuator for 8800 Series Recorders
HIO,9304 AU/NZ
Max input 600Vdc/ac peak.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 75
DATA ACQUISITION & RECORDING
Strip Chart Recorders
Yokogawa 3057-22 2 Pen Portable Recorder Yokogawa 3750-DC 20 Channel Hybrid Recorder
YEW,3057-22 AU/NZ YEW,3750-DC AU
Twelve input ranges 10mV~50V fs, 150mm x 15m Z fold or roll chart, speeds Input ranges dc 20mV~50V, thermocouple & RTD. Scans 20 channels in 2s.
20mm/h~600mm/min. Accuracy 0.5%. Power 240/50Hz, rechargeable Operates from 10~32V external dc. RS232C interface option fitted.
NiCad battery or 12Vdc external.
Yokogawa 3760 30 Channel Recorder
Yokogawa 3712-31 3 Pen Vertical Chart Recorder YEW,3760 AU
YEW,3712-31 AU Analogue and digital printout. Ten colour with channel identification number.
Input ranges dc voltage 10mV~200V fs. Thermocouples including type T Scans in 2s. Chart speeds 1~1500mm/h. Inputs dc (20mV~50V range),
& K. Chart speed 10mm/h~20mm/s. Pen offset compensation. Memory thermocouple (R, S, B, K, E, J, T, L, U, N, W, Kp) & RTD. Memory card
card optional. reader. Memory card included with several typical set-ups.
Yokogawa 3712-41 4 Pen Vertical Chart Recorder Yokogawa DR130 Hybrid 20 Channel Recorder FDD
YEW,3712-41 AU YEW,DR130 AU
Input ranges: dc voltage 10mV~200V fs. Thermocouples including type T Includes 3.5” FDD. Input unbalanced floating 20mV~50Vdc, TC, RTD and
& K. Chart speed 10mm/h~20mm/s. Pen offset compensation. Memory contact. Accuracy 0.05%. Reads 20 channels in 2s. Recording width
card optional. 150mm. Data can be saved to 500k of internal RAM either directly or due to
alarm conditions. The saved data can be copied to a 3.5” FDD file suitable
Yokogawa 3750 10 Channel Multipoint Recorder for inclusion in standard spreadsheet programmes.
YEW,3750 AU
Ten channel hybrid recorder. Input ranges dc 20mV~20V, thermocouple, Yokogawa 512K Memory Card for Yokogawa Recorders
RTD. Scans 10 channels in 2s. AC mains operation. YEW,MEM512 AU
Memory card 512k. For YEW,3750, YEW,3760, YEW,3712-31 YEW,3712-
41 and YEW,3701-85 recorders.

Voltage Current Recorders


Tech-Rentals CT Terminations for Hioki 8710, etc Hioki 8710 3 Channel ac/dc Recorder
TR,CT-5 AU HIO,8710 AU/NZ
Termination box for 5A output current transformers. For use mainly with Intended mainly for recording ac line voltage and current. Data is recorded
HIO,8710. Comprises quantity 3 shunts 0.04Ω. Output 0.2V @ 5A. Use graphically and printed. Input voltage ranges 70~750V rms ac in 4 ranges
with DRA,TR2015’s. with optimised scale, 0.05~7.5V dc in 5 ranges. AC current ranges using
9008 and 9132 clamp-on probes 10~1000A. Uses type 9221 thermal paper
Hioki 8206 2 Channel Voltage & Current ac Chart Recorder 110mm x 30m. The recorder is suitable for voltage measurements from PAM
HIO,8206 AU
thyristor inverters but not all voltage levels with PWM inverters. Chart speed
The chart records a true rms. Equivalent reading. AC voltage channel, 3
up to 30 div/min (1div is 9mm). Response time 0.6s.
ranges 50~140V, 100~280V & 250~600V. AC current channel, 0~10, 0~20,
0~50, 0~100, 0~200 & 0~500. Chart speeds 600mm/h~20mm/h. Note the
supplied 9651 clamp-on current probe will measure max 46mmØ conductor.
Frequency range of the clamp 40Hz~1kHz.

Tape Recorders
Teac 16 Channel DAT Instrumentation Recorder
TEA,RD145T AU
Sixteen channel DAT instrumentation/data tape recorder. 4ch~20kHz, 8ch-10kHz, 16ch~5kHz, ac/dc operation. Ch 1 can be selected for analogue or 14-bit
digital. Data recorded at slow speeds can be played back at double speed. Input ranges 0.5, 2, 5 & 20Vp impedance 100kΩ unbalanced output ranges 2~5Vp
variable impedance 75Ω unbalanced. AC or 11~30V dc operation.

Plotter Printer
HP 7440A 8 Pen Plotter
HP,7440A MY
Media sizes. 210 X 297mm (ISO A4) 8.5 X 11in (ANSI A). Regular plotter paper,glossy presentation paper, fast-dry overhead transparency film. 8 fiber-tip pens,
automatic pen changing & capping. Max plotting area: Y-axis 191mm (7.5in) for A & A4 size paper, X-axis 257mm (10.1in) for A size paper. Resolution:
addressable step size: 0.025mm (0.001 in). Pen Velocity: pen up 52 cm/s (20 in/s). pen down max 40 cm/s (16 in/s), programmable 1 to 40 cm/s in 1 cm/s
increments. Acceleration: approx 1.2 g’s. Interface Options: RS-232-C/CCITT V.24 Asynchronous serial, ASCII, 60-byte buffer size.Switch selectable baud
rates: 75~9600. Switch selectable parity: odd, even, or off. HPIB: Switch selectable addresses: 0~31 (31 sets listen-only mode). Size: 308(d) x 460(w) x
125(h)mm. Weight: Plotter 4.1kg. Power supply 1.4kg.

76
PHYSICAL MEASUREMENT
Pressure & Humidity Transducers
Analog Pressure Humidity Operating Temperature
Model Type Differential NATA Vacuum
Out (Bar) (%) (°C)
ASH,1000 1,000
DRU,PTX1400-4 4
DRU,PTX1400-25 25
4~20mA
DRU,PTX1400-40 40
DRU,PTX1400-400 400
Pressure
DRU,PTX1400-600 600
FLU,PV350 42
Yes
FLU,PV350-NATA 0~1V 24 Yes
GEM,2200BGB2501A3UA 25
4~20mA
GEM,2200BGC1001A3UA 100

KUL,HEM375-5000 High temp pressure 0~100mV 345 <270

ROT,HTO45R001V Temp & humidity 0~1V 25~90 5~50


SHA,P1041-10000 0~100mV 715
SHA,P1241-500 35
SHA,P1241-5000 357
SHA,P1241-10000 0~5V 690
SHA,P3061-4D Pressure 280mBar Yes
SHA,P53363-500 34.5
TRA,8204-ID-20A 4~20mA 1 Yes
TRA,8891-4-10V 0~10V 4
TRA,8891-4-20A 4~20mA 4
VAI,HMP-135Y Temp & humidity 0~100 %
0~5V
VAI,HMP-235Y Temp & humidity 0~100 %
VEG,BAR20 1
E&H,PMC-1-3BAR 1~+3 Yes
E&H,PM-1BAR 1
E&H,PMP-4BAR 4 -25~70
Pressure 4~20mA
E&H,PMP-40BAR 40
E&H,PMP-100BAR 100
JUM,1030-0-10BAR 10
-40~85
JUM,40BAR 40

Druck PTX1400-25 25Bar Pressure Transducer 4-20mA Druck PTX 1400 600Bar/9,000 PSI Pressure Transducer
DRU,PTX1400-25 AU DRU,PTX1400-600 AU
Pressure transducer, 4~20mA output, 0~25 Bar (360psi) input. Requires Output 4~20mA. Requires 9~32Vdc, supplied with 12V plug pack.
9~28VDC, supplied with 12V, 500mA power pack.
Druck PTX1400 400Bar/6,000 PSI Pressure Transducer
DRU,PTX1400-400 AU
Output 4~20mA. Requires 9~36Vdc, supplied with 12V plug pack.
Druck PTX1400 4Bar/60PSI Pressure Transducer
DRU,PTX1400-4 AU
Output 4~20mA. Requires 9~36Vdc. Supplied with 12V plug pack. Pressure
input connector G ¼” female.
Endress & Hauser 1~3Bar Transducer
E&H,PMC-1~3BAR NZ
Pressure transducer with flush face diaphram. Accuracy: 0.5% of FS.
Minimum vacuum 10mBar. Operating temp -25~70ºC. Response time 90%
of FS in 20ms. Output: 4~20mA. Pressure connection: ½”BSP.
Endress & Hauser 1Bar Transducer
E&H,PMP-1BAR NZ
Druck 580 PSI 40Bar Pressure Transducer 4~20mA Presssure transducer with flushable diaphragm. Accuracy: 0.5% of FS.
DRU,PTX1400-40 AU Operating temp -25~70ºC. Response time is 90% of FS in 20ms. Output:
Requires 9~36Vdc, supplied with 12V plug pack. 4~20 mA. Pressure connection: ½”BSP.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 77
PHYSICAL MEASUREMENT
Distance Measurement & Surveying
Digiroll Plus Measuring Wheel & Surveying Phantom 53550 Radar Gun kph, with Case and Tuning Fork
DIG,PLUS AU PHA,53550 AU
Measuring wheel. For linear measurement and, area and volume calculation Professional doppler K band (24.150GHz) stationary radar gun. Fast action,
of construction sites and buildings, etc. pull the trigger and the speed display appears instantly. Unit is invisible to all
radar detectors. Power requirements 10.5~16.5Vdc, 13.5Vdc nominal, 1.5A
Leica Disto Pro Laser Distance Measurement max, external source, connection via 6’ coiled power cord with fused lighter
LEI,DISTOPRO AU/NZ
plug. Operating environment -20~60ºC, 90%RH @ 37ºC (non-condensing).
Typical accuracy ±1.5mm. Will average over 8 measurements for greater
Accuracy ±0.17kph. Accuracy verification tuning fork (K-Band), internal
accuracy. Built in function for height measurement and enclosed angles,etc.
90kph. Speed range 17~332kph.
Memory can be divided into groups, e.g. 200 groups with 5 measurements.
Includes PC interface and software, telescope to help find dot in daylight and
bubble level to enable horizontal measurement.
Mitutoyo 500-172 Digimatic Caliper
MIT,500-172 AU
Range 0~200mm (0~8”), resolution 0.01mm (.0005”). Absolute measurement,
LCD display. Temperature operating range 0~40OC, storage temperature -
10~60OC. Button settings ON/OFF, inch/mm. Origin, zero/ABS.

Jenoptik LEM300-GEO Laser Range Finder & Speed Gun


JEN,LEM300-GEO AU
Includes precision inclinometer and compass. Measures up to 300m
horizontal or sloping distances. Distance measurements updated at 50Hz
so accelerations can be analysed via RS232 interface. Overall accuracy
±10cm. Rechargeable batteries.
Hilti PR50 Rotating Laser Level
HIL,PR50 AU
Mitutoyo Absolute Digimatic Height Gauge Caliper For facade installations, suspended ceilings, excavations, etc. PR50 is a
MIT,570-314 AU
self leveling rotating laser. System includes tripod and 2 styles of sight, the
Digital height gauge for measurement of height of small components/parts.
first make on audible alarm when the laser is detected, and the second when
Functions, origin (absolute origin) setting, ABS (absolute) measurement,
detected the system oscillates on to provide good definition of the laser in
INC (incremental) measurement, hold. Measurement range 24”/600mm,
high ambient light conditions. Accuracy ±0.7mm in 10m horizontal, ±0.9mm
resolution 0.0005”/0.01mm, error ±0.0020”/0.05mm, display 6 digit LCD.
in 10m vertical. Laser range 30m or more with beam catcher, 150m or more
with laser detector.
Hilti PM10 Multi Directional Laser
HIL,PM10 AU
Triple laser alignment system. Instrument produces 3 visible lasers each at
90O. Supplied with contractors kit including clamps, magnetic bracket, targets
in case. Accuracy ±3mm in 10m, self-leveling from ±4O to horizontal.

Tachometers/Stroboscopes

> NEW
Monarch Palmstrobe Compact Size Portable Stroboscope
MON,PALMSTROBE AU
> NEW
Monarch PLT200-KIT Digital Contact/Non Contact Tacho
MON,PLT200-KIT AU
Compact size portable stroboscope, flash rate from 100~12,500FPM, 6 Hand held digital contact/non contact tacho kit. Ranges optical/non contact
digit alphanumeric backlit LCD. Tachometer range 5~250,000RPM (only 5~200,000 RPM, contact 0.5~20,000 RPM. Display 5 digits, 5 alpha numeric
with external sensor connected, not included). External sensor input TTL LCD. Non contact operating range 90cm, tripod mounting. Direct contact
only. Supplied with 2 x removeable rechargeable battery packs, charger tips and contact wheel supplied. Programmable for IPM, FT/M, YPM, cm/M,
and transit case. m/M, RPM, RPS, RPH and Totaliser up to 200,000. Output TTL pulse.

78
PHYSICAL MEASUREMENT
Tachometers/Stroboscopes
Monarch Phaser Strobe Battery Operated Hioki 3404 Optical/Contact Tachometer
MON,PHASER AU HIO,3404 AU/NZ
Phaser-stroboscope includes optical and magnetic pickup. Operates from Autoranging 4 digit display. Ranges in RPM mode 30~99.9, 1,000~9,999
internal re-chargable batteries or mains. Auto step mode provides slow & 1,000~9999 x 10. Ranges in RPS mode 0.5~99.99, 100~999.9 &
motion appearance for high speed repetitive events. Stores and recalls last 1,000~1,600. Analogue output 1mV/10RPM or 1mV/100RPM, accuracy 4%.
3 full settings in memory. Specifications 30~30,000f/min or 0.5~533.33f/ Tripod mounting. Internal battery or external ac operation. Contact adaptor
s. Accuracy ±0.01%. Flash rate external triggering 30~9,999.9f/min, included with cone and peripheral ring.
0.5~533.33f/s, 10,000~32,500f/min. Phase delay facility.

Endoscopes
Model Type Diameter mm Length - Metre Articulation
FIB,MTFS15-1000 1.5 1 None
MOR,MSGI-1350 1.3
8 Semi rigid
MOR,MSPI-3000 3
Fibreoptic endoscope
MAC,FB5-1400A 4.3 1.25 2 way
OLY,IF8C5-30 8 3
OLY,IF11D4-20 11 4 way
OLY,IV6C6-20-ZOOM 6 2
OLY,IV6C5-20 51 2 way
OLY,IV8C6-35 Video endoscope 6 3.5 4 way
OLY,IV8D3-20 8.4 2 4 way
OLY,IPLEX-MX 6 3 4 way
OLY,CYF-3 6 0.37 2 way
Fibrescope endoscope
SIL,PF136 9 1.32 Semi rigid
AQU,SNAKEEYE Colour video flexible cable 30 9.1 None
WHO,VIPER CAMERA KIT Option for Minispring 51 - Rotating head
WOH,MINISPRING Colour video rigid push rod 22 20 None
WOH,VIS220 26 19.5   None
Colour video flexible cable
WOH,VIS2000 51 Rotating head
30
RAD,GATORCAM-25-30
B&W videoscope and recorder
RAD,GATORCAM-25-60 25 60 None
PEA,FLEXI-CAM Colour video pipeline inspection system 15
HEI,TECHNO-6X320 6 320mm
OLY,G100-034-090 55 Borescope 10 340mm
SYK,4-30-ARTHRO 4 180mm
DYO,750 Camera and video processor

Pearpoint Flexi-Cam Pipeline Inspection System Radiodetection Gatorcam-25-60 Drain Video Inspection System
PEA,FLEXI-CAM AU/NZ RAD,GATORCAM-25-60 AU
Compact colour video 25mm colour camera with 3lux sensitivity, (light Monochrome video scope 60m x 25mmØ. Kit includes video display and
source white LED’s) on 15m of fully retracting flexi-rod. Flexi-cam navigates VCR combination and 33kHz sonde capability so the camera location can
multiple 90O bends in 32mm pipes and images are displayed on the internal be determined using the RAD,RD400PXL. Has fixtures to center the camera
colour TFT screen. Images can be recorded to an external video recorder in larger diameter pipes. Camera includes variable illumination. Length of
(not supplied). System operates from internal fully rechargeable batteries cable extended is displayed and comments can be added to the image.
which provide up to 5h of continuous use when fully charged. Hand-held
Wohler Minispring 15m x 22mm B&W Inspection Camera
portability. Fully waterproof, manually set focus camera. Inspects pipes
WOH,MINISPRING AU
25~100mm.
Semi rigid push rod 20m long with 22mm colour camera. Waterproof to 15m.
Radiodetection Gatorcam-25-30 Drain Video Inspection System Kit includes a small battery operated display with a video output. Large
RAD,GATORCAM-25-30 AU display and recorder option.
Monochrome video scope 30m x 25mmØ. Kit includes video display and
VCR combination and 33kHz sonde capability so the camera location can
be determined using the RAD,RD400PXL. Has fixtures to centre the camera
in larger diameter pipes. Camera includes variable illumination. Length of
cable extended is displayed and comments can be added to the image.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 79
PHYSICAL MEASUREMENT
Endoscopes

> NEW Wohler VIS 220 Visual Inspection System for Pipes
and Drains
WOH,VIS220
Moritex PalmScope Video Capture Device for JPEG & Movie
Clip Recorder Inspection
MOR,PALMSCOPE AU
Compact colour video pipeline inspection system, 26mm colour camera Digital Video Recorder, image capture and storage. Used in conjunction with
with bright white LED’s on 19.5m of flexible push rod with metric marking. an endoscope, borescope or videoscope the PalmScope is an alternative to a
Camera sensitivity 3 Lux, lens f=2.5mm, F=2.0, view angle 120º, waterproof VCR for onsite inspection applications. Unit records, store video sequences
to 30m water depth. Suitable for insertion in pipes and spaces from 40 to and full frame resolution jpeg images on supplied 512Mb Compact Flash
150mm diameter. The system is supplied with 2 battery packs and an AC Card. View images on built in 6.4” TFT LCD screen. Stores jpeg still images
charger/power pack, each battery pack lasts approx 1.5h. Supplied with 5.6” and or mjpeg movie clips. Signal input video NTSC or PAL, auto-selecting.
TFT display with extension cable, video output suitable for video recorder
(not supplied).

Moritex 2C Mount Adaptor


MOR,2CMOUNT AU
Wohler VIS2000 30m x 51mm Steerable Color Camera 2C mount adaptor.
WOH,VIS2000 AU
Camera Mount for Moritex Eye Piece
For inspection of ventilation ducts, chimneys, chambers and flue gas
MOR,CAM-MOUNT AU
systems, etc. Kit consists of color display with joy stick to control the camera.
Mount to allow the connection of a standard camera to a Moritex endoscope.
Flexible 30m cable on a reel, with non-waterproof, splash resistant, 51mmØ
Adaptors connect to where you would normally add a filter to a camera. Ring
colour camera with illumination. Accessories included to assist for chimney
sizes which this can adapt to include 52mm, 49mm ,46mm & 37mm. Sony
inspection: a fixture to allow the camera to be lowered down chimneys, a
Mavica (SNY,MAVICA-FD95) can be used, or check the size of the filter
guide to centre the camera inside chimney-like spaces and a holder to allow
which is used on the camera.
the camera to look up rather than down.
Wohler Viper Camera Kit for Minispring
WOH,VIPER CAMERA KIT AU
> NEW
Silverado PF136 Portable Fibrescope
SIL,PF136 AU
Optional camera with remote control movement of camera for
Portable fibrescope, 9mm diameter, 1320mm working length, gooseneck
WOH,MINISPRING. Cannot be used on its own.
semi rigid insertion tube, supplied with 90º side view adaptor mirror. Built
Aqua Snakeeye 9m x 25mm Video Inspection in battery compartment for LED light source. Viewing direction 0°, viewing
AQU,SNAKEEYE AU/MY angle 45º, Depth of view 30mm to 150mm. Side view adaptor viewing
For remote inspection work. Very light and compact. Includes a 127mm direction 90º, viewing angle 45º, depth of view 30mm to 150mm, tip diameter
TFT-LCD display & 30mmØ camera including illumination. Various adaptors 10mm.
are supplied for mounting the camera to, your hand, 457mm with 90O
articulation arm or 9.1m extension cable.
Machida FB5-1400A 4.3mmØ x 1.25m Endoscope
MAC,FB5-1400A AU
End section steerable in 2 axis, 120O. Instrument is fragile due to the narrow
diameter and lack of a thick protective sheath. Light source included.
Moritex MSGI-1350 1.35m x 8mm Semirigid Endoscope
MOR,MSGI-1350 AU
MOR,MSGS-1350 NZ
Size 8mmØ x 1.35m long. Kit includes a 90O side view adaptor, when used
diameter is then 10.1mm. Includes battery light source. View angle 27O.
Focal length 10mm~infinity. Working temperature 0~60OC. Image 13,000
pixel. Optional video camera available.
Olympus CYF-3 6mm Diameter 37cm long Fiberscope
OLY,CYF-3 au
Fibrescope 6mm diameter, 37cm long fibrescope, articulation 190 deg up
and 90 deg down. Includes CLK-4 light source. Non metal insertion tube,
synthetic rubber.

80
PHYSICAL MEASUREMENT
Endoscopes
Olympus IPLEX- MX Portable Industrial Videoscope Olympus IV8D3-20 8.4mmØ, 2m Long Videoscope
OLY,IPLEX-MX AU OLY,IV8D3-20 AU
IPLEX MX battery powered industrial videoscope, lightweight just 4.5kg out Industrial flexible videoscope, 2m long, 8.4mmØ, distal tip non removeable,
of transit case. 6mmØ, 3m length tungsten insertion tube, articulation 4 way field of view 100O, depth of field 7-122mm (fixed focal point). Angulation 4
UP/DOWN/LEFT/RIGHT 120O. Field of view 120O, depth of field 18mm way, 120O UP/DOWN, 100O RIGHT /LEFT. Heavy duty tungsten insertion
to infinity, illumination method LED. Brightness adjustment 11 step, long braid tube. Operating temperature for insertion tube in air 0~50OC, in water
exposure up to 1sec, zoom electronic linear up to 3x, built in 5.6inch TFT 10~30 OC. Liquid resistance for insertion tube - withstand machine oil, light
full colour display, image recording built in, image format JPEG, over 230 oil and 5% salt water. Supplied with IV-5 video processor unit, ILK-5 light
images with supplied CF card. Powered from either rechargable Li-ion 2X source and TV/Video VHS recorder.
battery packs (4 hours) or AC adaptor.
Olympus IV8C6-35 Videoscope 8.4mm x 3.5m Long
OLY,IV8C6-35 AU
Fitted with AT80D/FF optical adaptor, field of view 80O, direction of view
forward, depth of field 40mm to infinity. Angulation 4 way, 150O in up/down
& left/right, heavy duty tungsten insertion braid tube. Operating temperature
for insertion tube in air -10~80OC, in water 10~30OC. Liquid resistance
for insertion tube - withstand machine oil, light oil and 5% salt water.
Supplied with IV-6 video control unit, ILH-2A light source and TV/Video VHS
recorder.
Dyonics Model 750 Video Camera & Processor
DYO,750 AU
For endoscopes and borescopes with British standard eye piece. TV/Video
recorder not included.
Olympus Endoscope/Recorder TV Camera Inspection Heine Techno 6mm x 320mm T.05.26.302 Borescope
OLY,VIDEO AU
HEI,TECHNO-6X320 AU
Video camera, monitor, VCR and adaptor kit to suit Olympus endoscopes.
Direction of view 70O, with angled extension tube 120O x 120O. Battery pack
Two mount adaptor.
included, dc supply cord, battery charger and mains power pack.
Olympus IF8C5-30 8mm x 3m Long Endoscope
OLY,IF8C5-30 AU
Length 3.25m (effective 3m), 8mmØ, angulation range, 4 direction, up/down
120O, right/left 100O, light guide cable length 2m. Optical adaptor fitted
AT60DFF, field of view 60O, forward viewing, depth of field 20mm~infinity.
Outer diameter 8.4mm. Operating temperature in air -10~80OC, in water
10~30OC. Operating pressure water 1,013~1,317hPa (1~1.3atm), air
1,013hPa (1-1.3atm). Fluid resistance insertion tube withstands machine
oil, light oil. Only insertion tube can be placed in water. Supplied with eye
piece and light source.
Olympus IF11D4-20 11.3mm x 2m Length Endoscope
OLY,IF11D4-20 AU
Working length 1.7m. Large sharp images with adjustable focus regardless Olympus G100-034 090 55 Borescope
of distance. Depth of field of view 8mm~infinity, field of view 78O, direction OLY,G100-034-090 55 AU
of view forward. Easy up/ down 120O, right/left 100O angulation of bending G series rigid borescope 340 mm, 10 mmØ, direction of view 90O, field of
section which can be locked at any angle. Includes Olympus ILK-5 light view 55O. Stainless steel insertion tube, operating temperature -20~150OC.
source, halogen lamp. Operating temperature insertion tube including Includes Olympus ILK-5 cold light source, Sony CCD-IRIS colour video
optical adaptor, in air -10~80OC, in water 10~30OC. camera, AK2-10C adaptor for Sony CCD-IRIS. View via eye piece or via
video connection to TV.
Olympus IV6C6-20-ZOOM Videoscope 6mm x 2m Long
OLY,IV6C6-20-ZOOM AU
Fitted with AT120D/NF optical adaptor, field of view 120O, direction of view
forward, depth of field 5mm~infinity. Angulation 4 way, 150O up/down &
left/right, heavy duty tungsten insertion braid tube. Operating temperature
for insertion tube in air -10~80OC, in water 10~30OC. Liquid resistance for
insertion tube - withstand machine oil, light oil and 5% salt water. Supplied
with IV-6A video control unit, which has zooming and virtual scrolling
(panning) with moving images function, extended exposure time for darker
areas, built in image enhancement and freeze frame. ILH-2B light source,
Panasonic 7” LCD colour monitor mounted on extension arm all fitted to
transit case for ease of use. Video VHS recorder also included in package.

Stryker Borescope 4 mmx 180 mm Long, 27.5O View


SYK,4-30-ARTHRO AU
Supplied with Quantum 4,000 light source, 597 camera head and video
processing unit. Very high quality system.
Fibrescope MTFS15-1000 1.5mm x 1m Endoscope
FIB,MTFS15-1000 AU
Working length 1.5mmØ x 1,000mm. Includes light source. Operating
temperature -20~60OC at atmospheric pressure.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 81
PHYSICAL MEASUREMENT
Microscopes
Olympus CH2 Binocular Microscope Chroma 7310 Video Microscope
OLY,CH2 AU CHR,7310 AU
Magnification of eyepiece x 10. Magnification of objective lens X4, X10, X40, High resolution colour camera X40 & X200 magnification. Includes
X100 (oil type) to give a max magnification of 1,000. In-built light source. illumination, auto gain control, auto white balance adjustment, etc. Freeze
picture and compare function.
Proscope SCA-12770 Video Microscope Kit
PRO,SCA-12770 AU Scalar VL-7EX Video Microscope
Hand-held USB video microscope complete kit. Includes 200X, 100X, 50X, SCA,VL-7EX NZ
1~10X interchangeable lenses, C Mount adaptor, stand and carry case. Handheld video microscope. View and capture images to a PC or TV/video
Connects to a PC via USB interface. Software allows snap shot still images recorder. Supplied with a X30 lens, video to USB adaptor and windows
and real time movie files to be saved. Resolution is 640 x 480 pixels. software. Optional 14” TV/video is available.
Polaroid Microcam Microscope Camera
POL,MICROCAM AU
Instant film camera for binocular microscopes. Simple over eyepiece fitting
permits use with virtually any model.

High Speed Video


Redlake Motionmeter High Speed Digital Camera Redlake Motionscope SR500 High Speed Video
RED,MOTIONMETER AU/NZ RED,SR500 AU
Up to 1,000frames/s, selectable 50, 60, 125, 250, 500 & 1,000frame/s, Triggering facilities similar to a digital oscilloscope. 2,048 frames can be
exposure rates 1X, 2X, 3X, 4X, 5X, 10X & 20X the recording rate. Manual captured up to 500frames/s. Shutter speeds 1/60~1/5,000s. Images can be
record, trigger record, adjustable pre trigger 0~100%. Storage 4,098 frames. viewed from a frame by frame basis to real time. Monochrome image. PAL
Playback rates 1,2,3,4,5,10,15,25,30,50, 60,125,250,500 & 1000frame/s. video output. TTL trigger input. Use any standard oscilloscope to supply the
Output composite video NTSC or PAL (monochrome) also supplied with signal. C mount interface on camera. System with C mount adaptor can be
video to USB converter, flood lights and tripod. used with endoscope.
Redlake 1000 Frames/Sec Motion Scope
RED,S1000 AU
Triggering facilities similar to a digital oscilloscope. 4,096 frames can be
captured at up to 1,000frames/sec. Images can be viewed from a frame
by frame basis to real time. Shutter speeds 1/60~1/10,000s. Monochrome
image 336 x 243 x 8-bit pixels. Weight 5.5kg. PAL video output. Trigger
input TTL. Use any standard oscilloscope to supply the signal. Adaptor can
be used with endoscope.
Orion VPDC ac/dc Powered Video Recorder
ORI,VPDC AU
PAL B/G portable video recorder includes NTSC Playback on PAL TV. Two
rotary heads, helical scanning system, 1 track audio.
Orion 10VRKT 23cm TV with built in VCR
ORI,10VRKT AU
AC/dc combination 10” (23cm) colour TV and video recorder. TV channels
VHF, UHF, audio output power 1.2W max. VCR PAL B/G, 2 head. Power
240Vac, 12Vdc. Supplied with remote control.

Pressure Vacuum Gauges/Recorders


Model Type Pressure (Bar) NATA Accuracy
BRI,1000-NATA 69
BRI,10000-NATA Pressure recorder 690 Yes 0.5%
BRI,5000-NATA 345
HOB,PRES Pressure logger 1.013 1% fs
STE,1000-NATA 69
STE,10000-NATA 690
Pressure gauge Yes 0.5%
STE,5000-NATA 345
TR,PRESS-NATA 100
CEC,140BAR 140
Digital gauge & logger No ±0.1%
CEC,30BAR 30

82
PHYSICAL MEASUREMENT
Pressure Vacuum Gauges/Recorders
Tech-Rentals 4,000, 6,000 & 10,000kPa Pressure Gauges NATA Stewart Buchanan 12 5,000 PSI Gauge NATA
Calibrated STE,5000-NATA AU
TR,PRESS-NATA AU Stainless steel, accuracy ±0.5% NATA calibrated. Pressure connection
Three gauges. Accuracy ±0.5% 4,000kPa, 6,000kPa & 10,000kPa. ¼”NPT.
Bristol Babcock 1,000psi Mech Chart Recorder Stewart Buchanan 12 10,000 PSI Gauge NATA
BRI,1000-NATA AU STE,10000-NATA AU
Circular pressure chart recorder 1,000psi. 12”Ø. Accuracy ±0.5% NATA Stainless steel, accuracy ±0.5% NATA calibrated. Pressure connection
calibrated. Fitted with 2 speed spring wound chart drive giving 7d or 24h ¼”NPT.
recording. Pressure connection ¼”NPT.
XP2i Digital Gauge & Logger 140Bar
Bristol Babcock 5,000PSI Mech Chart Recorder CEC,140BAR NZ
BRI,5000-NATA AU Intrinsically safe high accuracy temperature compensated pressure data
Circular pressure chart recorder 5,000psi. Description as above logger with IANZ calibration certificate. Records up to 3,000 pressure
measurements. Recording intervals or 1s~8h. Data download and analysis
Bristol Babcock 10,000 PSI Mech Chart Recorder on any Windows equipped laptop or PC. Data can be saved directly into MS
BRI,10000-NATA AU
Excel. Internal battery powers unit up to 3m. Can be used as a reference
Circular pressure chart recorder 10,000psi. Description as above.
gauge with or without a hand pump.
Stewart Buchanan 12 1,000 PSI Gauge NATA XP2i Digital Gauge & Logger 30Bar
STE,1000-NATA AU
CEC,30BAR NZ
Stainless steel, accuracy ±0.5% NATA calibrated. Pressure connection
Description as above.
¼”NPT.

Pressure & Humidity Transducers


Endress & Hauser 4Bar Transducer Vega Bar 20 0~1Bar Transducer with Display
E&H,PMP-4BAR NZ VEG,BAR20-1 AU
Description as per E&H,PMP-1Bar Output 4~20mA. LCD display and is rated IP65. Over pressure resistant
to 10bar & -1bar. Measurement accuracy 0.5%, linearity deviation 0.085%.
Endress & Hauser 40Bar Transducer May be set to bar, psi, kpa, mpa, mmH2O, mH2O & mbar. Output can be
E&H,PMP-40BAR NZ
4~20mA or 20~4mA. Integration time 0~10s. Density factor may be entered
Description as per E&H,PMP-1BAR
for mm & m, output simulation indication module has 20 segment bar graph
Endress & Hauser 100Bar Transducer and 4 digit display which may be scaled (has factory default reset). Supply
E&H,PMP-100BAR NZ required 12~36Vdc.
Description as per E&H,PMP-1BAR
Schaevitz P53363 500 PSI, 0~5V Pressure Transducer incl
Jumo 1030 10Bar Pressure Transducer Snubber
JUM,1030-0-10BAR NZ SHA,P53363-500 AU
Output 4~20mA. Accuracy is 0.5%. Temperature range -40~85ºC, response Output 0~5V.
time 30ms.
Schaevitz P1241 500PSI Pressure Transducer
Jumo 40Bar Pressure Transducer SHA,P1241-500 AU
JUM,40BAR NZ Output 0~5 V. Port ¼”BSP (f). Operation12Vdc or mains.
Output 4~20mA. Accuracy 0.5%. Temperature range -40~85ºC, response
Fluke PV350 Vacuum/Pressure Indicator
time 30ms.
FLU,PV350 AU
Schaevitz P3061-4D 4PSI Differential Pressure Transducer Can be used with a digital multimeter (eg Metrix MX45) to act as an indicator.
SHA,P3061-4D AU Range, pressure to 600psi (4137kPa) & vacuum 0~29.22”Hg (0~76cmHg ).
100” water gauge, 4psi. LVDT type with built-in amplifier. Output 0~5Vdc. Results in either psi or kPa. Connector ½”NPT (m). Cable 2.4m provided.
Operates from 10~32Vdc or ac mains. Battery powered.
Kulite 5,000PSI High Pressure Temperature Transducer 260OC Fluke PV350 Vacuum/Pressure Indicator, NATA Certificate
KUL,HEM375-5000 AU FLU,PV350-NATA AU
Includes 10V regulated supply. Output 0.020mV/psi. Specification as above but with NATA certificate.
Trafag 8891 4Bar/58PSI, 0~10V, Pressure Transducer Schaevitz P1241 10,000PSI 0~5V Pressure Transducer incl
TRA,8891-4-10V AU Snubber
Accuracy ±0.3% FS. Overpressure 10bar (145psi). Output 0~10V. Pressure SHA,P1241-10000 AU
connection G ¼” male. Bandwidth 1kHz. Media temperature 125OC. IP65 Pressure transducer 10,000psi, includes snubber, 0~5V output.
rated. Power supply 15~30V.
Ashcroft 1,000 Bar Pressure Transducer
Trafag 8891 4Bar, 58 PSI, 4~20 mA, Pressure Transducer ASH,1000 AU
TRA,8891-4-20A AU Range 10~36Vdc supply. Output 4~20mA. Connection ¼”NPT (M).
Accuracy ±0.3% FS. Overpressure 10bar (145psi). Output 4~20mA.
Pressure connection G ¼” male. Bandwidth 1kHz. Media temperature
GEM,2200BGC001A3UA 100Bar Pressure Transducer
GEM,2200BGC1001A3UA AU
125OC. IP65 rated. Power supply 10~30V.
Can be used with a digital multimeter (eg Metrix MX45) to act as an
Trafag 8204 1Bar ,14PSI, 4~20mA, Differential Pressure indicator. Transducer could be used with a chart recorder or data logger that
Transducer can accept 4~20mA signal input. Pressure range is 100Bar (10,000KPa or
TRA,8204-1D-20A AU 1,450psi). Transducer has a 4~20mA output. Power supply and connection
Same specification as above. leads are supplied.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 83
PHYSICAL MEASUREMENT
Pressure & Humidity Transducers
Rotronic Temperature/Humidity Transducer for DataTaker Vaisala HMP 235Y 180OC Humidity Probe
DT600/605 VAI,HMP-235Y AU
ROT,HTO45R001V AU High temperature humidity and temperature transmitter. Sensor head
Humidity range 25~90%RH 10mV/%RH accuracy 3% resolution 0.6%. operates from 0~180OC. Measurement range 0~100%RH. Accuracy of
Temperature range 5~50OC, 10mV/1OC accuracy 1O, rep 0.2OC. Datataker 1%RH at 20OC. Output 0~5Vdc. Other outputs easily set including 4~20mA.
will supply around 100mA through switched supply. Response time 10s Operates from 15~30Vdc or ac mains.
humidity, 20s temperature. Duct mount model 120mm long x 25mmØ.
Vaisala HMP 135Y 160OC Humidity Probe
Supply 4.8~24Vdc draws 4mA.
VAI,HMP-135Y AU
Same specification as above but sensor head operates from 0~160OC.

Position Transducers
Houston 1850-40 Position Transducers Unimeasure P510-40 Position Transducer
HOU,1850-40 AU/NZ UNI,P510-40 AU
Linearity 0.1% travel 40” (1m). Cable tension 280g. Max velocity 132cm/s. Travel 40” (1m). Output 0~5V or 0~10V selectable. Requires 12~30Vdc
Output is a variable resistance arranged to provide both high level (V) and source.
low level (mV) outputs when powered from an external source.

Inclinometers
Wyler Clinitronic 45 Inclinometer RS-232C
WYL,CL45 AU/MY
Resolution 0.01O. Accuracy better than 30arc sec. Display inclination in all common measurements. Includes RS232 interface for remote display of
inclination and also logging. Settling time <5s.

Force Gauges
Model Type Analog Out (V) RS232 Nata Range(kg) Resolution (g)
AME,CADET-25N 2.5 12.5
MEC,AFG-1000N Force gauge 0~1
Yes 100 100
MEC,AFG-1000NALC No

Ametek Cadet 25 Digital Force Gauge Mecmesin AFG-1000NALC Digital Force Gauge
AME,CADET-25N AU MEC,AFG-1000NALC AU
RS232C interface. Range 0~25N (2.5kg), resolution 0.3N (1g), accuracy Range 0~1000N accuracy 0.1%. 5 digit back lit display. Peak data sampling
0.5% of full scale. Deflection 1mm. Display 4 digit LCD. Bi-directional rate 5kHz. 120% overload warning, display invert (reverse) function, dual
with peak hold for compression & tension. NiCd operated. 1Vdc recorder max, max tension & max compression plus current reading. Outputs:
output. analogue, RS232 & Mitutoyo. Accessories: test hook, compression plate,
130mm & 30mm extension rods, rotary coupling. Mounting tapped holes x
Mecmesin AFG-1000N Digital Force Gauge 2, M5 x 0.8 x 5.5mm deep max. Optional smart sensors can be used, such
MEC,AFG-1000N AU
as TW60 static torque wrench.
Range 0~1,000N accuracy 0.1% (1 ton) 5 digit display. Sampling rate
1kHz. Overload protection and counter. Outputs analog, RS232 & Mitutoyo. Mecmesin TW60 Torque Wrench
Accessories, test hook, 12mmØ compression plate, 30mm & 130mm MEC,TW60 AU
extension rods. Range to 60Nm, optional accessory to be used with MEC,AFG-1000NALC
Force Gauge. Smart interface, as soon as plugged into force gauge scaled
accordingly.

84
PHYSICAL MEASUREMENT
Load Cells
Model Type Range (kg) Output (V)
BAR,MTC-150 68 0~5

BAR,STC-500 230
0~2
BAR,STC-500NATA 230g
AIC,SG-AST-500 500 0~10

BAR,STC-4400 Load cell 2,000


BAR,STC-5000 2,270

BAR,STC-10000 4,536 0~5

BAR,STC-20000 9,072
BAR,STC-25000 12,000

EMC,100KG 100

EMC,200KG Tension load cell 200 Yes


EMC,1000KG 1000 Yes

STR,1590C Compression load cell 8,000

DIL,ED2000R 20,000
Crane scale RS232/485
DIL,EX2000 – 5K 5,000

AND,WEIGH-BEAMS Platform Scale 2,000

AND Mercury Platform Weighbeams for Pallet up to 2,000kg Barlo STC-4000 4,400lb/2,000kg Load Cell
AND,WEIGH-BEAMS AU BAR,STC-4400 AU
Total weight capacity 2,000kg for the 2 weigh beams. Two stainless steel Range 2,000kg compression and tension. Complete with series interface
weigh beams supplied, length 1200l x 100w x 80hmm, weight 13kg each. operating from 12Vdc or ac mains. Output 0~5Vdc. Cable to digital display
Connection cable length 5m. AD4406 display supplied, RS232 output. unit 6m. Uses ¾”UNF thread.
Transit case with handles and wheels for ease of handling.
Barlo STC-5000 5,000lb/2,270 kg Load Cell
BAR,STC-5000 AU
Range 2,270kg compression and tension. Interface operates from 12Vdc or
ac mains. Output 0~5Vdc. Display resolution 1kg.
Barlo STC-10000 10,000lbs/5,000kg Load Cell
BAR,STC-10000 AU
Range 4,536kg compression and tension. Interface operates from 12Vdc or
ac mains. Output 0~5Vdc.
Barlo STC-20000 20,000lb/10,000kg Load Cell
BAR,STC-20000 AU
Range 9,072kg compression and tension. Interface operates from 12Vdc or
ac mains. Output 0~5Vdc.
Barlo MTC-150 150lb/68kg Load Cell
BAR,MTC-150 AU
Range 68kg compression and tension. Complete with interface operating
from 12Vdc or ac mains giving 0~5Vdc output.
AIC SG-AST-500 500kg S Type Load Cell with Panel Display
AIC,SG-AST-500 AU
Tension and compression 500kg. Nominal output 2mV/V, max excitation
15Vdc, IP67 protection, safe load 125%, compensated temperature range
-10~40OC. Thread M12 x 1.75P. Supplied with 2 x detachable rod end
bearings, PM4 -SG-dc-5E load cell panel meter, power 12~48V dc, ac
adaptor supplied, output 0~10V. Panel indication in kg.
Barlo STC-500 500lb/230kg Load Cell Barlo 25,000 lb/12,000 kg Load Cell and Display
BAR,STC-500 AU BAR,STC-25000 AU
Complete with conditioning electronics. Output 0~2V. Uses ½”UNF thread. Complete with 10m cable. Includes D shackles, analog and RS232 output.
12,000kg load capacity.
Barlo STC-500 500lb/230kg Load Cell NATA Calibrated
BAR,STC-500NATA AU
Specification as above but with NATA calibration. This load cell is suitable
for tension only.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 85
PHYSICAL MEASUREMENT
Load Cells
EMC 100kg Tension Load Cell Dillion ED2000 5,000 kg Crane Scale
EMC,100KG NZ DIL,ED2000-5K AU
100kg S type tension load cell with digital indicator. Accuracy ±0.3% of Complete with shackles. Range 5,000kg. Accuracy 0.1%. Resolution 1kg.
reading. Operating temperature range -18~65ºC. Safe overload is 150% of i.e. 20kg uncertainty. Units of measure: kg, kt, mt, & lb. Proof load 200%
rated capacity. Supplied with threaded eye hooks. Analogue output. of rated load. Displays gross and net force. Continuous measurement and
peak hold.
EMC 200kg Tension Load Cell
EMC,200KG NZ
200kg S type tension load cell with digital indicator. Specification as per
EMC,100kg
EMC 1000kg Tension Load Cell
EMC,1000KG NZ
1,000kg S type tension load cell with digital indicator. Specification as per
EMC,100kg
EMC Load Cell Conditioner
EMC.L/CELL-COND NZ
Load cell conditioning unit with a recorder output. AC mains powered.
Strainstall 8,000kg Compression Load Cell
STR,1590C NZ
8,000 kg compression pedestal load cell.
Dillon ED2000 Crane Scale 20,000kg with Radio Remote
Control
DIL,ED2000R AU
UWE 5,000kg Digital Crane Scale
Complete with shackles and radio remote control unit. Range 20,000kg.
UWE,CS-5T NZ
Accuracy 0.1%, i.e. 20kg uncertainty. Units of measure kg, kt, mt, & lb.
Battery powered digital crane scale complete with hook & shackle. Load
Resolution 5kg. Proof load 200% of rated load. Displays gross and net force.
capacity 40kg~5,000kg, resolution 2, accuracy is ±10kg. Built in large LED
RS232 and RS485 data outputs. Continuous measurement and peak hold.
display, wireless remote control, and charger.

Materials Testing

> NEW
Anton Paar DMA 35N Portable Density Meter
PAA,DMA35N
Hydramotion Viscolite 700 Portable Viscometer
HYL,V700S-21 AU
Advanced portable viscometer with stainless-steel probe. Operating range
Portable density, specific gravity & concentration meter. Measuring range 0.1~10,000mPaps (cP) with integral temperature correction -40~150ºC.
0.000~1.999g/cc and 0.0~40.0ºC. Built-in pipette style pump for sample Probe tip 21mmØ, immersion length 115mm (viscosity only) or 145mm
aspiration, with port for optional syringe-filling. Display of specific gravity, (viscosity/temperature). Acetal polymer probe base for handheld or clamped
ºBrix, ºBaumé, %alcohol, proof, ºPlato, API, or %H2SO4. Rated intrinsically operation, with coiled-cable connection to meter unit with 5 digit display.
safe [ATEX] for use with batteries, petrochemicals and solvents. Data Battery powered.
storage of up to 1024 results, with recall, and infrared port for RS232
download to serial printer or PC. Wetted parts glass and PTFE. Battery
powered.

86
PHYSICAL MEASUREMENT
Scales & Balances
Model Type RS232 Range (g) Resolution (g)
AND,GR-202 Analytical balance Yes 210 or 42 0.1mg or 0.01mg
AND,FC-10K 10kg 0.02
AND,HF-300G Yes 310 0.001
AND,HP-40KA 20kg 0.5
Counting scale
MET,PB8000I 8.1kg 100mg
ISH,CCS3025 25kg 5mg
OHA,EXP4100 4,100 0.01
AND,AD4714 70 0.01
Moisture balance Yes
AND,MX50 51 0.001
AND,FG-150KB Platform scale 150kg 0.05
AND,HL400 Scale 400 0.1
AND,FS-15KA 15kg 1
Weighing Scales
MET,15KG 15kg
MET,60KG 60kg
AND,WEIGHBEAMS Platform Scale Yes 2000 0.05

A&D Mercury Platform Weighbeams for Pallet up to 2000kg A&D HF-300G Mercury 300g Counting Scales
AND,WEIGH-BEAMS AU AND,HF-300G AU
For pallet weighing. Total weight capacity 2000kg for the two weigh beams. Scales 310g, resolution 0.001, repeatability 0.001. Includes RS232 port.
Two stainless steel weigh beams supplied, length 1200mm, width 100mm, Includes counting software. Can be used as counting scales.
height approximate 80mm, weight of each beam 13kg. Connection cable
Ishida 25kg Digital Counting Scales
length 5 metres. AD4406 display supplied, RS232 output. Transit case with
ISH,CCS3025 NZ
handles and wheels for ease of handling.
Maximum capacity 25kg, resolution 5g. Features: unit weight, sample
weight and tare.
A&D Mercury MX50 Moisture Analyser
AND,MX50 AU
Maximum sample weight capacity 51g, resolution 0.001g, moisture content
accuracy over 1g, 0.1%, over 5g, 0.02%. ,Halogen lamp heater, 400W
max. Drying temperature 50~200OC. Measurement programs 20 sets,
measurement mode moisture content, wet or dry, dry content, ratio, weight.
Heating mode standard, automatic, quick, timer, manual. Display large VFD,
interface RS232C, CD-ROM software supplied. Pan sample size diameter
85mm.

A&D Mercury AD4714 Moisture Balance Scales


AND,AD4714 AU
Moisture content to 0.1%. Sample weight 5~70g. Includes timer and RS232
interface. Weight readability 0.01g. Max temperature 200ºC, heater 185W
infrared.
Ohaus EXP4100 4100g Balance and Counting Scale
OHA,EXP4100 AU
Capacity 4.1kg. Display resolution 0.01g. Multi-unit display. Repeatability
0.005g. RS232 interface.
A&D Mercury FS-15kg Weighing Scales Mettler PB8001 8kg Counting Scales
AND,FS-15KA AU
MET,PB8001 AU
High resolution 15kg scales. Display resolution 1g. AC & NiCad battery
Capacity 8.1kg with 0.1g readability. Sample size selectable 5~100. Can do
operation.
taring, percent and dynamic weighing. Powered by battery eliminator.
A&D Mercury FC-10K Counting Scales A&D Mercury HL400 Scale 400g x 0.1g
AND,FC-10K AU
AND,HL400 AU
High resolution 10kg scales with sample counting facility. Display resolution
Battery operated balance, range 400g, resolution 0.1g
1g, internal resolution 0.02g. Sample size user selectable – normally 10
pieces. Max count size up to 999,999. AC & NiCd battery operation. A&D GR-202 Mercury Dual Range Analytical Balance
AND,GR-202 AU
A&D HP-40KA 40kg Counting Scale Two-layer construction, splash-proof keyboard and front operating door-
AND,HP-40KA AU
lever. Range 210g x 0.1mg & 42g x 0.01mg. One-touch calibration and
Capacity 40kg with 0.5g resolution. Can be used to determine battery weight
automatic self-calibration outside preset temperature limits. Functions
change with charge, etc.
include multiple weighing units, counting or %, data memory, adjustable
A&D Mercury FG-150KB 150kg Scales environment setting and GLP management. Bidirectional RS232C standard.
AND,FG-150KB AU Low-voltage operation with ac adaptor.
Capacity 150kg, 0.05 resolution. Includes RS232 port. National Standards
Mettler 15kg Weighing Scales
Commission approved (NSC).
MET,15KG MY
Mettler 60kg Weighing Scales
MET,60KG MY

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 87
NON-DESTRUCTIVE TESTING
Vibration & Alignment Analysis
Frequency
Max
Model Type Application Features Range
Acceleration (G)
(Hz)
Monitoring vibration for
Logging outdoors
ARL,EL-235 Ground vibration logger pile driving and general
enclosure
construction vibration
BK,2635 Accelerometer charge amp
BK,4230 Sound level meter calibrator NATA
BK,4333 2~10,000
BK,4343 Accelerometer 10,000
2~12,000
BK,8301
BK,4370 0.2~5,4kHz 2,000
BK,4371 0.2~12.7kHz 20,000
Single axis accelerometer
PCB,300A20 Low G will operate down to DC dc~300 20

Explosion and general Logging outdoor


Blast logger and ground vibration
TEX,ATM construction vibration enclosure, tri-axial 4.5~500
logger
monitoring geophones
BLA,UMX-SM-6 Blast logger Explosion monitoring Tri-axial geophones

CSI,ULTRASPEC Balancing system & vibration analysis Balancing & spectral analysis

Vibration table (requires frequency Shake source for testing


LAB,LW-140-141
source) purposes
Includes thermal
PRU,ROT Allow for the alignment of non
Optical machinery shaft alignment growth analysis
rotating shafts
PRU,ROT-ULTRA
RIO,CP-10 Printer For use with RIO,VA-10
Hand held
RIO,VA-10
accelerometer

Vibration analyser Machinery condition monitoring Hand held & magnetic


accelerometer
RIO,VA-11
PC memory card
capability
Magnetic
RIO,VM82 Vibration meter Machinery and monitoring
accelerometer
Whole body vibration Includes whoopee
SVA,912A & SVA,SV06A Tri-axial accelerometer & analyser +/-50
measurement cushion
Shipping and packaging
TIN,SHOCKSET Single axis shock logger Logging capability
analysis
PIE,308B Accelerometer with amp 1~3kHz
Logging vibration for
Tri-axial transportation
MAD,SHOCK101 Tri-axial Bump Logger transportation i.e. trucks,
logging
containers

Pruftechnik Rotalign Ultra Laser Shaft Alighment


PRU,ROT-ULTRA AU
Laser based rotating shaft alignment system. Maximum separation between
emitter and receiver 10m. Aligns horizontal and vertical machines, aligns
coupled and uncoupled shafts equally well. Ultra modern computer design,
backlit colour display, Intel XScale 400MHz CPU, USB for peripheral devices,
PC, printer, also Bluetooth communication. Backlit keyboard, rechargeable
Li-Ion battery pack. Machine train alignment- 14 machines. Alignment
results in 3 quick steps, thermal growth computation. Rotalign Ultra Reader
software included.

88
NON-DESTRUCTIVE TESTING
Vibration & Alignment Analysis
Pruftechnik 1500mm Length Tension Chains B&K 4343 Accelerometer
PRU,AL12.116 AU BK,4343 MY
1500mm length tension chains for PRU,ROT-ULTRA. Accelerometer. Frequency range: 2~12,000Hz. Charge sensitivity 10~mV/g.
Charge sensitivity 10pc/g. Maximum shock 10000g.
Pruftechnik Rotalign Shaft Alignment
PRU,ROT AU B&K 4370 Accelerometer
Max alignment distance 10m. Aligns horizontal and vertical machines. BK,4370 AU
Graphical display of alignment condition. Resolution 1micron, angular better Frequency range 0.2Hz~5.4kHz. Voltage sensitivity 100mV/G or 8mV/ms2
than 10µRad. (approximately) into 20GΩ. Charge sensitivity 100PC/G or 10PC/ms2. Max
sinusoidal acceleration 2,000G. Max shock 2,000G. Requires 1 charge
Pruftechnik Magnetic Sliding Bracket amplifier.
PRU,MAG-BRKT AU
Designed to be used with the Rotalign. Used when shafts to be aligned B&K 4371 Accelerometer
cannot be rotated. A bracket is required for each non-rotating shaft to be BK,4371 AU/MY
aligned (ie. usually 2 will be required). Frequency range 0.2Hz~12.7kHz. Voltage sensitivity 10mV/G or 0.8mV/Ms2
(approximately) into 20GΩ. Charge sensitivity 10PC/G or 1PC/MS2. Max
Madgetech Ultrashock-EB Transportation Logger sinusoidal acceleration 6,000G. Max shock 20,000G. Requires 1 charge
MAD,ULTRASHOCK-EB AU
amplifier.
Ambient temperature, humidity, pressure and 3 axis shock acceleration
logger. Ranges: -40~180ºC, 0-95%RH, 0~30PSIA (0-200kPa), -50g~50g. B&K 8301 Accelerometer
Memory 23,831 readings per channel. Logging interval from 1 reading per BK,8301 MY
2s to 1 reading per 12h. Sampling rate 2ms. Includes RS232 interface and Accelerometer. Frequency range: 2~12000Hz. Sensitivity 10mV/g. Charge
setting up, downloading, graphing software. sensitivity 10pc/g. Maximum shock 10000g.
Madgetech Shock101-EB TR-Axial Transportation Logger B&K Vibration Impact Hammer
MAD,SHOCK101 NZ BK,8202 AU
Battery powered, stand alone 3-axis shock recorder, extended battery life of For determining frequency response functions. Individually calibrated force
up to 60 days typical. Measures and records shock as the peak acceleration transducer. Comes with 3 different tips and additional mass to enable pulse
levels over the user defined interval. Designed for documenting dynamic duration and frequency range to be determined.
environments such as moving vehicles, containers, ships, etc.
Piezotronics Accelerometer and Amplifier
Tiny Tag, Set of 6 Loggers: 3 x Shock, 2 x Temperature, PIE,308B AU
1 x Humidity Accelerometer frequency range 1Hz~3kHz ±5%, 0.7Hz~6kHz ±10%,
TIN,SHOCKSET AU voltage sensitivity 100mV/g or 10.2mV/m/s2 ±2%. Range: ±50g, ±5V
For shipping and transport testing. Includes 3 x shock loggers; these record output, resolution 0.001g, vibration max 500G, shock max 5,000G. Supplied
the max G force in the programmed period. Includes a humidity logger, with PCB482A10 ICP line power unit.
an internal temperature logger and temperature logger with external probe.
Linear Accelerometer +/-1G dc Response
Set also includes an f computer to download and view the results.
LIN,LSPC-1 AU
Svantek 912A Sound Vibration Analyser Designed for very low force levels ±1G measurement range. Operates
SVA,912A AU down to dc in frequency. Output ±5V. Linearity 0.05%, resolution 0.001%.
Type 1 sound level meter including a single axis accelerometer. Provides Shock Survivability 100g. Natural Frequency 100Hz.
standard sound measurements and vibration measurements including
Rion VM82 Vibration Meter
1/1 octave, 1/3 octave and full spectrum. Unit will store 1Mb of spectrum
RIO,VM82 NZ
analysis information for waterfall plots etc. PC interface software included.
Single axis. Measure acceleration from 0.02~200m/s2. Velocity from
Unit can make part body vibration measurements. If whole body vibration
0.1mm~1m/s rms. Displacement from 0.001~100mm. AC/dc output of 1V
measurements are to be made the SVA,SV06A accessory must be used.
full scale.
Svantek SV06A Tri-axial Accel Interface for 912A Rion VA-10 Vibration Analyser
SVA,SV06A AU
RIO,VA-10 AU/MY
Accessory kit for human whole body vibration measurement. Provides
Vibration analyser for rotating machinery. Measures acceleration, velocity
4 accelerometer inputs for the SVA,912A and a tri-axial accelerometer
and displacement. Stores 500 readings. LCD display with waveform,
‘whoopee cushion’ for whole body vibration. Can operate as an interface for
spectrum and data readout. Auto measurement function. Includes printer
a standard B & K tri-axial accelerometer.
interface.
PCB Low G Accelerometer dc to 300 Hz Rion CP-10 RS-232 Printer VA10 NL05 NL14
PCB,300A20 AU
RIO,CP-10 AU/MY
Single axis accelerometer includes charge amplifier. Range ±20g,
Printer for RIO,VA-10. Operates from optional NiCd battery pack.
frequency (±5%) dc~300Hz, (±10%) ~500Hz. Shock limit ±5kg. Operating
temperature -40~85OC. Weight 15g. Voltage sensitivity 100mV/g. Rion VA-11 Vibration Analyser
RIO,VA-11 AU/MY
B&K 2635 Charge Amplifier Includes 2 pickup types hand held (PV55) and magnetic type (PV57).
BK,2635 AU/MY
Instrument will measure acceleration, velocity and displacement. Displays
Built-in integrators for displacement and velocity. Sensitivity to 10V/PC.
rms, peak and crest factor. Uses FFT to display power and vibration
Bandpass filters. Operates also from external 6~28Vdc or ±14Vdc. Battery
spectrum. Incorporates PCMCIA card flash memory for data storage. RS-232
operated 100h life. Required with accelerometers.
interface is available. Specifications PV57 1Hz~5kHz, PV55 3Hz~20kHz
B&K 4333 Accelerometer (velocity 3kHz, displacement 500Hz). Acceleration 0.02~316mm/s2 rms.
BK,4333 MY Velocity 0.1~1,000 mm/s rms. Displacement 0.003~28.3 (EQ PP). High
Frequency range: 2~10,000Hz. Voltage sensitivity 14~24mV/g. Charge pass filter 3Hz, 10Hz & 1kHz. Low pass 1kHz, 5kHz & 20 kHz. Stores 500
sensitivity 14-20pc/g. Maximum sinusoidal acceleration 7500g. Maximum measurements.
shock 10,000g.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 89
NON-DESTRUCTIVE TESTING
Vibration & Alignment Analysis
Texcel ATM Explosion and Ground Vibration Logger ARL EL-235 Tri-axial Ground Vibration Logger
TEX,ATM AU ARL,EL-235 AU
Triaxial geophone and overpressure (airblast) microphone with logger used Portable logger with human exposure capability. Monitors ground and
to determine explosion and ground vibration characteristics. Geophone building vibration for long periods. Calculates and stores tri-axial vibration
range to ±55.6mm/s, resolution 0.014mm/s up to 6.95mm/s, 0.109mm/s stats, vector sum stats, peak particle velocity (PPV), rms particle velocity
up to 55.9mm/s. Microphone range 80-dBL~140dBL, resolution 0.049Pa and human exposure (HEF) stats. Includes PC based analysis software.
up to 122dBL (25Pa), 0.40Pa up to 140dBL (201Pa). Sample rate 20, 50, Sensor frequency response 1Hz~500Hz. Logs interval, date, time, Leq,
100, 200, 500Hz & 1kHz. Bandwidth: geophone 4.5Hz~500Hz, microphone Lmax, temperature, battery, L0.1, L1.0, L10 & L90. Event mode logs date,
2Hz~500Hz. Includes software and download cable. Internal memory 2Mb. time, max and duration (Real time mode = 1000 samples/s). Stores up to
Power internal 12V dc 7Ah batteries. Continuous operation 240h. Supplied 4,096 intervals or events. Power 70mA @ 12V.
with 90~260V 50/60Hz charger, recharge time 8h approx. Instrument with
Blastronics UMX-SM-6 Explosion Logger
16 character LCD display, built into weatherproof pelican enclosure, rated
BLA,UMX-SM-6 AU
IP65. Operating temperature range 0~70OC, display 0~50OC. Also supplied
Triaxial geophones, microphone with logger used to determine explosion
with alarm light, reset button and 2 x 15m cable, ideal for vibration sensitive
characteristics. Geophones auto-ranging to 110mm/s, resolution ±0.1.
construction projects. External dc power supply cable also supplied.
Microphone auto-ranging to 140dBL, resolution ±0.25dB. Sample rate
250, 500Hz & 1kHz. Bandwidth geophones 4.5~500Hz. Microphone
2~500Hz. Includes software and download cable. Internal memory 4Mb.
Power internal 6Vdc 2,600mAh Gel-cells, operating consumption 40mA,
sleep mode 10mA. Continuous operation 65h, with 1w programmable timer
schedule. Instrument has a display.
Labworks LW-140-141 Vibration Table
LAB,LW-140-141 AU
Capable of random and sine movement. Sine force 489N, random force
334N, shock force 1kN, max displacement 25mm, max velocity 17.8m/s,
accel bare table 110g pk, accel 45kg 55g pk, accel 2.2kg 18g pk. Max accel
resonant 150g pk, max accel peak shock 200g pk. Unit requires a signal
source and an accelerometer to measure the acceleration. Signal source
could be a function generator or random noise generator.

Gloss Measurement
Elcometer 402 Glossmeter
ELC,402 AU
Measures the gloss or specular reflection from a variety of surfaces. Range 0~199.9 gloss units per ISO 2813-1978. Measuring angles 60O & 20O. Aperture
16 x 33mm ellipse. Digital display. Statistical functions – min, max, average, standard deviation. Stores up to 4,000 readings. RS232C interface for a printer.
Operates from ac mains or internal rechargeable batteries.

Automotive
Translock Brake Tester and Light Transmittance Meters
TLI,BTM2-LTM2 AU
Kit contains a brake tester and a light tester check vehicle conformance for the NSW Road Worthy Certificate. Brake tester measures the deceleration rate of
the vehicle and the light tester measures the transmission levels of light through the windscreen.

Non-Destructive Testing

> NEW
Panametric NDT Epoch-LT Ultrasonic Flaw Detector
PAN,EPOCH-LT au
> NEW
Panametric NDT Kit of 3 Transducers, Wedges & Cal Block
PAN,TRAN-KIT au
Handheld flaw detector with fast and bright LCD mono display, update rate Kit of 3 Ultasonic transducers, comprising 1X V540SM angle beam
60Hz, automated transducer calibration. Display freeze holds waveform and transducer 13mm, 2.25MHz, 1X V541SM angle beam transducer 13mm,
soundpath data, soundpath data viewable in inch, mm or microseconds. Peak 5MHz, 1X Single crystal transducer, 0DEG, 13mm, 5MHz, 3X wedge, 1X
memory feature, RF display mode, alarms, theshold positive/negative, or 45DEG, 1X 60DEG, 1X 70 DEG. 1X 1M lemo cable, 1X 5 step calibration
minimum depth. Numeric data logger. EMAT probe compatibility (E110-SB). block, 12.5, 10.0, 7.5, 5.0, 2.5mm (1018 steel).
Standard DAC and TVG. Software options fitted- Echo-Echo and Square
wave pulser. No probes supplied or connection cables. Refer PAN,TRAN-
Phynix Ferrous/Non Ferrous Coating Thickness Tester
PHY,SURFIX FN AU
KIT.
Thickness tester with memory and statistics. Supplied with external probe,
calibration standards and carry pouch. Measurement range 0~1,500µm or
0~60mils (selectable), tolerance ±1µm +3% of reading, resolution 0.1µm.
Display back light, 4 digit alphanumeric. Min measuring 5 x 5mm, min
substrate thickness type F 0.5mm, type N 50µm. Calibration factory, zero,
foil. Data memory 80 readings max. Interface infra-red down load data to
PC utilising hyper terminal.

90
NON-DESTRUCTIVE TESTING
Non-Destructive Testing
Defelsko FNS2 Ferrous & Non Ferrous Coating Thickness
Tester
DEF,FNS2 AU
> NEW
PCWI 40kV Pulse Porosity (Holiday) Detector
PCW,P40-PULSE AU
Storage of up to 250 readings. Supplied with external probe, calibration Pulse porosity (Holiday) detector. Detects pinholes in coatings and wrapping
standards and carry pouch. Measurement range 0~1.5m or 0~60mils above 150µm on metal substrates such as pipes and tanks. Can be used
(selectable), tolerance 0~50mm ±1mm, +1% of reading, greater than 50mm on dry or wet surfaces. 0~40kV output, 4 digit LED display of voltage, alarm
±2µm, +1%, resolution 0.1mm. Backglow display, HiLo limits audible and sensitivity setting between dry and wet. Supplied with rechargeable battery,
visible alerts when measurements exceed specified limits. Continually 10h charger, red probe handle and 2m length of rubber coated cable, 60mm
displays updates average, standard deviation, min/max thickness and connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat
number of readings while measuring. Hi resolution mode for greater brass wire brush, 450mm probe extension and 80mm probe extension.
precision. Built in infra red port for down loading data.

PCWI Hi-Lighter Holiday Detector


PCW,HI-L AU/NZ
Detects pinholes in coatings and wrappings on metal substrates such as
pipes and tanks. 0~20kV, 3½ digit LCD display of voltage, variable alarm
Elektrophysik Mini-100FN Coating Thickness Meter level. Portable with rechargeable batteries, includes probe and handle,
ELE,MINI-100FN AU extension probes and a variety of brass wire brushes for both flat and curved
Measuring range 0~1500µm, tolerance ±2µm or 3% of reading. Operates surfaces such as pipes.
on both ferrous and non-ferrous substrates.
PCWI 30kV DC Porisity (Holiday) Detector
Defelsko POS100-C3 Ultrasonic Thickness Gauge PCW,DC30 AU
DEF,POS100-C3 AU DC Porosity (Holiday) detector. Detects pinholes in coatings above 150um
Measure coatings on concrete, paint and lacquer on wood, paint on plastic, on metal substrates such as pipes and tanks. 0-30kV, 3.5 digit LCD display
paint on glass, glazing on ceramic, floor coatings, etc. Range 50µ~4.5mm with battery indicator, display of voltage level. Alarm indicated on front panel,
±2µ, ±3% of reading. Calculates max, min, mean, tolerance and SD. Stores supplied with rechargeable battery, 10h charger, probe handle with neon
1,500 readings in 100 groups for statistical calcs. PC interface & software. and 2m length cable, 60mm connector for flat brushes, 7m earth cable with
Battery operated. clamp, fan brush, 250mm flat brass wire brush, 450mm probe extension.
Dry conditions.
Defelsko Positest Pull Off Adhesion Tester for Concrete &
Metal PCWI 40kV Pulse Porosity (Holiday) Detector
DEF,POSITEST AU PCW,DC30-PULSE AU
Measures the force required to pull a specified test diameter of coating away Pulse Porosity (Holiday) detector. Detects pinholes in coatingsand wrapping
from its substrate using hydraulic pressure. Pressure is displayed in both above 150um on metal substrates such as pipes and tanks. Can be used
MPa and PSI on a precision dial indicator and can be related to the strength on dry or wet surfaces. 0-40kV output, 4 digit LED display of voltage, alarm
of adhesion to the substrate. Suitable for coatings on both metal and sensitivity setting between dry and wet. Supplied with rechargeable battery,
concrete surfaces. Conforms with standards ASTM D4541 and ISO 4624. 10 hr charger, red probe handle and 2m length of rubber coated cable, 60mm
connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat
> NEW
PCWI High Voltage Pulse Crest Meter
PCW,HV-PULSE CREST AU
brass wire brush, 450mm probe extension and 80mm probe extension.
Mitutoyo S-211 Surface Roughness Gauge
Measure and indicate peak voltage. MIT,S-211 AU
Surface roughness tester comprising an LCD display and a detachable
detector/drive unit. Parameters measured in Ra, Rz, and Rmax units. Tip
radius 5mm. Data output. NiCd batteries.
Mitutoyo SJ-201P Surface Roughness Tester
MIT,SJ201-NATA AU
Comprises LCD display and a detachable detector/drive unit. Parameters
measured in Ra, Rq, Ry, Rz, Rt, Rp, R3z, Rk, Rpk, Rvk, S, Sm, Pc, mr, Mr1,
Mr2, A1, A2, Vo units. Ranges: 350, 100, 50µm & 10µm, resolution from
0.01~0.4µm. Tip radius 5mm. Data output. NiCd batteries.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 91
NON-DESTRUCTIVE TESTING
Non-Destructive Testing
Mitutoyo 293-330 Digital Micrometer Panametrics 36DL Plus Thickness Gauge
MIT,293-330 AU PAN,36DLPLUS AU
Water resistant and coolant proof (IP65) digimatic micrometer, measuring Large display (A-scan), which displays the returned waveform. Echo-
range 0~1”, 0~25mm. Resolution .00005”, 0.001mm , quantizing error echo through-paint capability. Supplied with WIN95 software and cable.
±1 count, LCD display. Temperature operating range 5~40OC, storage - Supplied probe is 11mmØ with 1~500mm operating range and -20~500OC
10~60OC. Button settings: origin, zero/ABS, inch/mm, hold. temperature operating range. Instrument has a MIL-STD-810E hazardous
area operation.
Panametrics 25DLHP Thickness Gauge
PAN,25DLHP AU
Designed for fiberglass, rubber composites and castings. Measures
standard steel, copper, etc. Does echo-echo measurements. Measures
the thickness of material under paint, etc. Built in 5,000 reading datalogger
and an RS232 port.
Krautkramer DMS Thickness Gauge
KRA,DMS AU
Complete with echo verification and logger. Includes high temperature probe
and cable. Incorporates a wave form display for accurate assessment of
material under test, measurement of thickness whilst ignoring external paint.
Probe will operate to 200OC without cooling, up to 540OC with cooling.
Measurement ranges 0.75mm~250mm (for different ranges other probes
Panametrics 26 mg Pocket Thickness Gauge are available). Resolution 0.01mm. Stores up to 80,000 readings or 1,200
PAN,26MG AU/NZ readings with full waveform information.
Range 1~500mm, fast min mode. Resolution 0.01mm. Probe operates -
Sonatest Thickness Gauge
20~150OC.
SON,T-GAGE-IV+ AU/MY
Panametrics NDT 37DL-Plus Ultrasonic Thickness Gauge Range 0.63~500mm, resolution 0.01mm, high speed scanning mode,
PAN,37DL-PLUS AU selectable backlight, alarm mode, differential mode, RS232C output,
Thickness gauge with large display (A-scan), which will display the returned data send using hyper terminal. Supplied with high temperature probe,
waveform. It has echo-echo through-paint capability. Supplied with WIN37DL temperature range 0~340ºC.
PLUS software and cable. The supplied probe is 11 mm diameter with a
1~500 mm operating range and a -20~500OC temperature operating range.
The instrument has a MIL-STD-810E hazardous area operation.

Concrete Testing Equipment


ELE Type EL35-2020 Concrete Cover Meter Protimeter SM Moisture Meter
ELE,EL35-2020 AU/NZ PRO,SM AU
Non-destructive measurement of concrete thickness above steel Moisture meter for survey work. Very good for determining wet points. Can
reinforcement rods. Measures rod diameter. Depth range 360mm for rod be used on both concrete and timber. Subsequent accurate measurements
diameters 6~40mm & 200mm depth for rod up to 6mmØ. Small search can then be made.
head 80H x 50mmØ. Provides a high resolution capability when mapping
Proceq LR Concrete Test Hammer
out reinforcement structures. Range 100mm with 6mm bar to 120mm with
PRO,LR AU
40mm bar. Battery operated.
Concrete hardness tester (Schmidt hammer). Supplied with in-built
Profometer-4 Rebar Locator mechanical chart recorder. Impact energy 0.735Nm, 0.075kgm. For concrete
PRO,PROFO-4 MY thickness less than 100mm.
Rebar locator.
Protimeter CMIII Concrete Moisture Meter
Steinkamp BP7 Ultrasonic Concrete Tester PRO,CMIII AU
STE,BP7 AU Measures concrete moisture content using 2 methods. Firstly using
Measures the time a signal takes to propagate through a material. Used for impedance as a direct instant method. Secondly an accurate method
concrete refractory bricks, tile (fired and unfired), outcropping rocks, tunnel requiring placing a box on the concrete and measuring the humidity
walls, frozen ground, electrolytic carbon, plastics, adhesion, cast iron and generated by the concrete.
wood etc. Technique relies on the fact that the pulse velocity relates to the
materials tensile strength. Instrument can be used to determine % steel in
concrete, variations in the moisture content, measurements of crack depth,
voids, etc.

92
NON-DESTRUCTIVE TESTING
Concrete Testing Equipment
Protimeter Moisture Measurement System Hilti PS20 Rebar, Copper Pipe & Electrical Cable Locator
PRO,MMS-PLUS AU HIL,PS20 AU
Moisture meter for detection of moisture in non conductive solid materials Localise and position of reinforcement, (rebars) copper, aluminium pipes
such as wood and masonry. Two measurement modes, search for qualitaive and unshielded live electric cables. Depth range for detection of rebars
measurements and measure mode for precise and locaised moisture 0~100mm, for copper & aluminium pipes 60mm, rebar diameter 8~36mm,
content. Supplied with pin type probes, deep wall probes, hygrometer probe depth detection accuracy 10~30mm ±2mm, above 30-60mm ± 2mm ±10%
and extention cord,for RH, ambient temperature or dew point temperature. depth, above 60~80mm ±5mm ±10% depth, based on 12mm rebars.
Hygrostick probe supplied for surface temperature measurement. Logging Detection of copper & aluminium pipes based on 10~30mmØ, only detection
software and RS232 computer interface supplied. with depth of 0~60mm, no depth reading, same for live electric cables,
cannot detect live cables in metal conduit or shielded cables.
Proceq 2000-ND Digi Schmidt Test Hammer
PRO,2000-ND AU
Concrete hardness tester (Schmidt hammer). Supplied complete with inbuilt
graphical LCD for setting up and graphical display of results,up to 500 results
can be stored. RS232 interface and software supplied for down loading.
Impact energy 2.207Nm. Engineering units of results in N/mm2, MPa, psi,
kg/cm2. For concrete thickness greater than 100mm.

Hilti Ferroscan Concrete Reo Scanner


HIL,FERROSCAN AU
Reinforced concrete imaging system. Displays depth of concrete coverage,
location of reinforcement rods and anchor setting points. Fast, simple
operation. Depth mode allows reinforcement rods at different depths to
be viewed. Printer interface and PC interface and software allow images
to be printed and/or stored for further use. Depth coverage up to 180mm.
Reinforcement rod diameter measurement range 6~36mm. Area covered
Olsen FTG Concrete Thickness Gauge in a single measurement run 600 x 600mm; 42 image memory allows total
OLS,FTG AU
15m2 coverage without downloading.
Concrete thickness gauge utilising the impact Echo test method. Can
measure concrete thickness in two ranges: 6 to 60cm and up to 1.8m.
This concrete thickness gauge is a battery operated handheld system for
measuring the flaws and thickness of concrete slabs, pavements, walls and
other plate-like structures from one side. Up to 300 readings can be stored
in the field before the memory is full. RS232 interface and transfer software
supplied.

Hardness Testers
Krautkramer DynaPocket Rebound Hardness Tester Proceq Equotip Hardness Tester
KRA,DYNAPOCKET AU PRO,EQUOTIP AU
Based on the Leeb’s method HL, utilising a 3mm tungsten carbide ball. Test probe on a flexible lead. Probe type D is standard catering for most
Other hardness scales can be selected, HS Shore, HB Brinell, HRB Rockwell materials. Measurement ranges steels 80~650HB, 80~940HV, 20~68HRC,
B, HRC Rockwell C, HV Vickers and N/mm2 tensile strength. Choice of 9 aluminium castings 20~160HB, cast iron 90~380HB, brass 40~170HB &
material groups can be selected, they are St Low-alloy/unalloyed steel and copper wrought alloys 43~315HB. Test hardness must not exceed 940HV.
cast steel, ASt Tool steel, SSt Corrosion resistant steel, GCI Gray cast iron, Battery operated.
NCI Nodular graphite cast iron, AL Aluminium cast alloys, brS Brass, brZ
Bareiss HPE FM02177 Shore A Hardness Tester
Bronze, Cu Wrought copper alloys.
BAR,HPE-FM02177 AU
Durometer tester for general rubber, elastomer, soft plastic, tires, rubber
rolls & rubber hoses. Surface min 35mmØ, material thickness of 6mm are
necessary for a hardness test according to the standards. Hardness tests
can be conducted in a vertical, horizontal positions and on places which are
difficult to reach. Test time setable from 0~30s. Reading exactness of ±0.5
Shore and according to set down standards deviation of ±1 Shore.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 93
GENERAL INDUSTRIAL EQUIPMENT
Industrial Calibrators
Analog Pressure Vacuum Current Current
Model Type Battery RS232 Accuracy %
Out (Bar) (Bar) mA Source mA
AMB,CAL-20MPA Pressure pneumatic 200 0.5 fs
AME,HL2700N Dead weight tester hydraulic 225 0.05 reading
AME,PPCE-NATA* Pressure hydraulic 700 0.04 reading 50
BEA,BIC200 Industrial incl. Pressure 1 100 50
DRU,DPI603-10-NATA* 10
DRU,DPI603-20 20
0.85 0.075 fs 55
DRU,DPI603-2NATA* 2
Pressure pneumatic
DRU,DPI603-20NATA* 20 Yes
55
DRU,DPI610-20NATA* Yes Yes 0.025 fs 24
Yes
DRU,DPI610-160 160 0.025 fs 24
DRU,UPS-3 0.01 24
Current loop
DRU,UPS-IS 0.25 55
FLU,725
FLU,725-NATA* Industrial 110 22
FLU,743B
Yes
FLU,744 Industrial (hart)
FLU,700S/W-DPC-
S/ware for Fluke 743B & 744
TRACK
GRA,W6-NATA* Water bath 0.1
HAL,KAL84 Very low pressure 10 Yes Linearity ±0.5%
DRU,DBC150TC 0.3°C
HAR,9100-A 0.5°C
HAR,9105-NATA* Dry well temperature 0.1
HAR,9107-NATA* Yes 0.1°C
HAR,9141-NATA* 0.5
JOF,LPC-NATA* Pressure Yes 10 0.8 Yes 0.1 fs 200m
SER,NOVA-1 Dry well temperature 0.1°C
SI,PC6-2-NATA* 2 0.85
SI,PC6-20-NATA* Pressure pneumatic 20
YES 1.0 Yes Yes 0.025 fs 50 50
SI,PC6-40-NATA* 40
SP,PC6-1000-NATA*
HAR,9150 Thermocouple furnance No Yes ±0.5°C
HAR,9170-R-NATA* Metrology well calibrator Yes ±0.01°C
±0.5°C~200°C,
Temperature surface probe
HAR,3125-NATA* Yes ±1%~400°C
calibrator
JOF,1200SE Temperature calibrator 150~200°C
HAR,7102-NATA*
Temperature micro bath Yes ±0.25°C
HAR,7103-NATA*
FLU,718 Yes
SI,PC6-PRO 350 350
Pressure calibrator
DRU,DPI610-2-NATA* 2 -1 Yes 0.025°C ±55 0~24
DRU,DPI610-400-NATA* 400 Yes 0.025°C ±55 0~24
SI,HTP1 1,000
Pressure pump
SI,TPI-40 40 -1
* Nata Calibrated

94
GENERAL INDUSTRIAL EQUIPMENT
Industrial Calibrators
Freq Loop
Freq Resist RTD/ Temp Voltage Voltage
Model Type Source Power
kHz Measuremt TC Source °C Max V Source V
kHz V
AME,PPCE-NATA* Pressure hydraulic 30
BEA,BIC200 Industrial incl. Pressure 48 200Ω 100
DRU,DPI603-10-NATA*
DRU,DPI603-20
50
DRU,DPI603-2NATA*
DRU,DPI603-20NATA* Pressure pneumatic 24
DRU,DPI610-20NATA*
DUR,DPI610-20IS
DRU,DPI610-160 24 10
DRU,UPS-3
Current loop
DRU,UPS-IS
FLU,701-NATA* 500
FLU,725
Industrial 50 5
FLU,725-NATA* 24 11kΩ Yes 300 11
FLU,743B
500
FLU,744 Industrial (hart)
FLU,700S/W-DPC-
S/ware for Fluke 743B & 744
TRACK
GRA,W6-NATA* Water bath 0~150
HAL,KLA84 Very low pressure
DRU,DBC150TC -45 (below amb) ~ 150
HAR,9100A 40~300
HAR,9105-NATA* 40~650
Dry well temperature
HAR,9107-NATA* -45~140
HAR,9141-NATA* 40~650
SER,NOVA-1 200~1,000
SI,PC6-2-NATA
SI,PC6-20-NATA* Pressure pneumatic
24 24 10
SI,PC6-40-NATA*
SP,PC6-1000-NATA* Pressure Hydraulic
HAR,9150 Thermal couple furnance 150~1,200
HAR,9170-R-NATA* Metrology well calibrator -45~140
Temperature surface probe
HAR,3125-NATA* 35~400
calibrator
JOF,1200SE Temperature calibrator 150~1,200
HAR,7102-NATA* -5~125
Temperature micro bath
HAR,7103-NATA* -30~125
FLU,718
SI,PC6-PRO 350
Pressure calibrator
DRU,DPI610-2-NATA* +50 10,24
DRU,DPI610-400-NATA* +50 10,24
SI,HTP1
Pressure pump
SI,TPI-40
* Nata Calibrated

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 95
GENERAL INDUSTRIAL EQUIPMENT
Industrial Calibrators
Fluke 5500A Multi Product Calibrator with NATA Calibrated Fluke 743 Calibrator
FLU,5500A-NATA AU FLU,743B AU/MY
Calibrator sources direct voltage & current, alternating voltage and current, Includes RS232 interface. DC voltage measurement 0.025%, 300V max,
with multiple waveforms and harmonics, 2 simultaneous voltage outputs source 0.01%, 15V max. DC current measurement 0.025%, 110mA max,
or voltage & current. Simulates power with phase control, resistance, source 0.01%, 22mA max. Resistance measurement 0.05%, 11kΩ max,
capacitance, thermocouples and RTDs. Selectable ranges include the source 0.01%, 11kΩ max. Frequency measurement 0.5%, +5, 40~500Hz,
following outputs Vdc from 0~1.02kV, Vac from 1mV~1.02kV with output from source 1 count 20Hz~5kHz. ‘K’ thermocouple measurement 0.3ºC, source
10Hz~500kHz. AC current from 0.01µA~11A with output from 10Hz~10kHz. 0.3OC Pt100. RTDs measurement 0.3ºC, source 0.1ºC. Measures and
DC current from 0~11A. Resistance values from short circuit to 330MΩ. simulates 4~20mA, t/c E, N, J, K, T, B, R, S, & C, 2, 3 & 4 wire RTDs,
Capacitance values from 330pF~1,100µF. Temperature t/c B, C, E, J, K, L, frequency, test limit switches. Can use scaling factors for measurement &
N, R, S, T, U, RTD Pt385 100Ω, Pt3926 100Ω, Pt3916 100Ω, Pt385 200Ω, source. Built in calculator. Autostep function. Allows user entered values.
Pt385 500Ω, Pt385 1kΩ, Ni120 120Ω & Cu427 10Ω. Operates as a 8k point data logger. Note PC software only supports 15
tags.
Fluke 725 Process Calibrator
FLU,725 NZ Fluke 744 DOC Calibrator with Hart
DC voltage measurement 0.025%, 300V max, source 0.02%, 11V max. FLU,744 AU/NZ/MY
DC current measurement 0.025%, 110mA max, source 0.01%, 22 mA Documenting process calibrator which includes HART communication
max. Resistance measurement 0.05%, 11kΩ max, source 0.01%, 11kΩ protocols for communicating with and setting up smart transmitters. RS232
max. Frequency measurement 5 counts 1Hz~50kHz, source 1 count interface. DC voltage measurement 0.025%, 300V max, source 0.01%, 15V
20Hz~5kHz. ‘K’ thermocouple measurement 0.3ºC, source 0.3ºC. Pt100 max. DC current measurement 0.025%, 110mA max, source 0.01% 22mA
RTD measurement 0.5ºC, source 0.2ºC. Measures and simulates 4~20mA, max. Resistance measurement 0.05%, 11kΩ max, source 0.01% 11kΩ max.
t/c E, N, J, K, T, B, R, S, & C, 2, 3 & 4 wire RTDs and frequency. Operates Frequency measurement 0.5%, +5, 40~500Hz, source 1 count 20~5kHz. ‘K’
from drycell batteries. thermocouple measurement 0.3ºC, source 0.3ºC Pt100. RTDs measurement
0.3ºC, source 0.1ºC. Measures and simulates 4~20 mA, t/c E, N, J, K, T, B,
Fluke 725 Process Calibrator NATA Calibrated R, S & C, 2, 3 & 4 wire RTDs, frequency, test limit switches. Uses scaling
FLU,725-NATA AU
factors for measurement & source. Built in calculator. Autostep function.
Specification as above but with NATA calibration.
Allows user entered values. Operates as an 8k point data logger. Note PC
software only supports 15 tags.

96
GENERAL INDUSTRIAL EQUIPMENT
Industrial Calibrators
Fluke 700 Pxx Series Pressure Modules
FLU,700PXX
Assortment of Pxx series pressure modules for the Fluke 741/744 process
NZ > NEW Hart 3125 Surface Probe Calibrator 35~400ºC NATA
Certification
HAR,3125-NATA AU
calibrators. Temperature range 35~400ºC. Display accuracy ±0.5~200ºC, ±1~400ºC.
Stability ±0.2~300ºC, ±0.3~400ºC. Resolution 0.01º. Heating time
Druck DBC150TC Dry Well Calibrator Calibrator 25~400ºC 22min. Cooling time 400~100ºC 65min. Temperature surface
DRU,DBC150TC AU
plate 3.8ӯ accessible.
Temperature range -45(below ambient)~150ºC. Accuracy 0.3ºC, resolution
0.01ºC, stability 0.03ºC. Well standard insert supplied 145mm deep, 5, 6.6
& 9.8mmØ. Heating time 14min 20~120ºC, cooling time 22min 25~-20ºC.
Calibrator also measures sensor outputs, it can measure 5 types of RTD
& 11 types of thermocouple. Supports 2, 3, 4 wire RTD and provides cold
junction compensation for thermocouples.

Hart 9141 Dry Block Temperature Calibrator 50~650ºC


HAR,9141-NATA AU
Range 50~650ºC, basic accuracy 0.5% (holes > ¼” 2ºC). Insert hole sizes
1/16”, 1/8”, 3/16”, ¼”, 3/8” & ½”. Includes PC software and interface cable.
Heating time 1min to 650ºC. Cooling 25min from 650ºC~100ºC. Well depth
4.875”. Stabilization time 7min.
Hart 9150 Furnace 150-1200ºC
HAR,9150 AU
Temperature range 150~1200ºC. Stability ±0.5ºC, display accuracy of ±5ºC
across entire range. Display resolution 0.1º~999.9ºC, 1º above 1,000ºC.
Well diameter 1.25”, well depth 5.5”, insert type A. 1/16”, ¼”, ⅜”, 3/16”, ⅛”,
Hart 9105 Dry Block Temperature Calibrator -25~140ºC NATA ½”. Heating time 35min to 1,200ºC, cooling time 140min.
HAR,9105-NATA AU
HAR,9105 MY
Range -25~140ºC, accuracy 0.1, resolution 0.01, stability 0.02. RS232
interface for ramp and soak programming. Well dimensions 150mm deep,
19, 5, 3 & (2x) 6mmØ. Heats and cools in less than 10min. NATA certified.
Hart 9107 Dry Block Temperature Calibrator -45~140ºC NATA
HAR,9107-NATA AU
Range -45~140ºC, accuracy 0.1, resolution 0.01, stability 0.02. RS232
interface for ramp and soak programming. Well dimensions 150mm deep,
19, 5, 3 & (2x) 6mmØ. Heats and cools in less than 10min. NATA certified.

> NEW Hart 9170-R Metrology Well Calibrator with Built-in


Reference & NATA Certification
HAR,9170-R-NATA AU
Temperature range -45~140ºC with bult in reference thermometry. Reference
input accepts (not supplied) 100, 25 and 10ohm PRT’s. Display accuracy +/-
Jofra 1200SE Precision Temperature Calibrator
0.1ºC, stability +/-0.005ºC full range, resolution 0.001ºC. Well depth 6.3”,
JOF,1200SE MY
insert type A 1/4, 3/16, 1/4, 1/8, 1/4, 3/8”. Large LCD, numeric keypad and
Lightweight, portable for lab and general use. Simple single step zero setting.
on screen menus. Heating time 32min 23~140ºC, 45 minutes -45~140ºC,
Temperature range 300~1200ºC. Excellent performance characteristics.
cooling time 44min 23~-45ºC, 19min 140~23ºC. Supplied with RS232C
Accuracy +2ºC. Stability +0.5ºC. Display in ºC or ºF to 0.1 resolution. Fast
interface and CD-ROM software.
cooling and heating. User-selectable slope rates for controlled thermo switch
testing. Self diagnostics includes semi-auto Switch Test & Hysteresis Test.
Grant W6 Temperature Bath NATA Certified
GRA,W6-NATA AU
Water/oil bath calibrator for calibrating temperature probes. Ranges water
ambient 100ºC; silicon oil ambient; 150ºC. Requires 3L oil (not supplied).
Digital temperature controller and display. Stability 0.004ºC. Uniformity
0.01ºC. Display resolution 0.1ºC. Tank size 300w x 150d x 150hmm.

Hart 9100-A Dry Block Temperature Calibrator 30~300OC


HAR,9100-A NZ
Stability is 0.2ºC @ 50OC & 0.3ºC @ 300ºC. Accuracy for 35~200ºC ±0.5
for 200~300ºC ±1, for well holes greater than ¼” ±2ºC.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 97
GENERAL INDUSTRIAL EQUIPMENT
Industrial Calibrators

> NEW
Hart 7102 Temperature Micro Bath -5~125ºC
HAR,7102-NATA AU
> NEW
Jofra C650 Calibrator
JOF,C650 MY
Range -5~125ºC. Tank diameter 1.9”, 5.5” deep, volume 0.75L, includes A fast, timesaving, and reliable true temperature calibrator designed for on-
tank lid. Accuracy ±0.25ºC, stability ±0.015ºC at -5OC, ±0.03ºC @ 121ºC, site use. Produces temperatures between 33~650°C. Display resolution
resolution ±0.01ºC. Heating time 25~100OC 30min, cooling time 25~0ºC ±0.1°C, accuracy ±0.9°, stability 0.1°C. Well depth 120mm x 28Ømm.
30min. RS232C interface and CD-ROM sofware supplied. Comes with a multi-hole insert of ⅜”,¼”, 3/16” & ⅛”Ø holes. Light weight
and portable.

> NEW
Hart 7103-NATA Micro Bath -30~125ºC NATA Certification
HAR,7103-NATA NZ
Temperature range -30~125ºC. Tank 2.5”Ø, 5.5” deep, volume 1L, includes Jofra LPC Pressure Calibrator NATA Calibrated
tank lid. Accuracy ±0.25ºC, stability ±0.03ºC @ 25ºC, ±0.05ºC @ 125ºC, JOF,LPC-NATA AU
resolution ±0.01ºC. Heating time 25~100ºC 35min, cooling time 25~-20ºC Range to 10bar (145psi). Display 4½ digit, can display in bar, psi, mercury &
45min. RS232C interface and CD-ROM software supplied. H2Og. Analogue output 2Vdc. Includes adaptors ¼”BSP to various BSP &
NPT. Measures pressure and vacuum. Battery operated.
Druck DPI603 2Bar Pressure Calibrator NATA Calibrated
DRU,DPI603-2NATA AU
Accuracy 0.075% fs includes pump for vacuum and pressure. Pumps to
20bar pressure & -850mbar vacuum. Measurements can be made to 2bar
positive pressure & -1bar vacuum. Unit has a 24V energising voltage.
Monitors loop current to 55mAdc loop voltage to 50V. Sealed to IP65.
Rechargeable battery operated. Displays in 24 different units. Interface
1
/8”BSP.
SI PC6-2-NATA Pressure Calibrator & Pump -1~2Bar 0.025%
Accuracy
SI,PC6-2-NATA AU
Druck UPS-IS Current Loop Calibrator SI,PC6-2 MY
DRU,UPS-IS AU
Range -1~2bar. Measures voltage 0~100mV (1µV resolution), 0~5V (0.1mV
Intrinsically safe 4~20mA source and measurement. Provides 24V loop
resolution) & 0~50V (1mV resolution) & current 0~50mA (1µA resolution) all
power. Accuracy 0.25%. Input and output resolution 10µA.
at 0.025% accuracy. Will sources 0~10V (0.2mV resolution) & 0~50mA (1µA
Beamex BIC200 Instrument Calibrator resolution) also at 0.025% accuracy. Voltage output regulated 10V ±0.1%,
BEA,BIC200 AU/MY current 30mA and unregulated supply 24V ±10% current 50mA. Pressure
For both electronic and pneumatic instruments. Output ranges settable to switch status. Complete with a full range of pressure connection adaptors.
119.9% of range 0~10V, 1~5V, 4~20mA, 0~20mA, 10~50mA & 0~50mA. Record logging capability 444 and RS232 interface download to spread
Output source for current ranges 24 & 48V. Input ranges to 4½ digit display sheet files. Battery operation 10h or mains operation via charger.
100mV, 1, 10 & 100V, 100mA, 4~20mA, 200Ω. Pressure measurement
SI PC6 Pressure Calibrator & Pump 20 Bar 0.025% Accuracy
ranges 0~1bar & 0.2~1bar. Operates from internal NiCd batteries or external
SI,PC6-20-NATA AU
ac.
Basic accuracy 0.025%. Range output pressure to 20Bar, output vacuum
Halstrup KAL84 0-1kPa Portable Pressure Calibrator to -1Bar. NATA certified Instrument. Measures voltage 0~100mV (1µV
HAL,KAL84 AU resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) and current
Portable battery operated 0-1.000kPa (0-10mbar) low pressure calibrator. 0~50mA (1µA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV
Linearity ±0.5% ±1 digit, hysteresis 0.1%, medium - air and all non resolution) & 0~50mA (1µA resolution) also at 0.025% accuracy. Voltage
aggressive gases, pressure connections 6.5mm hose NW5, interior tubing output regulated 10V ±0.1% current 30mA and unregulated supply 24V
5mmØ. Analogue output 0-1V, display 41/2 digit, power supply via mains ±10% current 50mA. Pressure switch status. Battery operation 10h or mains
adaptor 100-240Vac & NiCd re chargable battery pack. operation via charger. Complete with a full range of pressure connection
adaptors.
SI PC6-40-NATA Pressure Calibrator & Pump NATA Certified
SI,PC6-40-NATA AU
Basic accuracy 0.025%. Range is 40bar. Measures voltage 0~100mV (1µV
resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) & current
0~50mA (1µA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV
resolution) & 0~50mA (1µA resolution) also at 0.025% accuracy. Voltage
output regulated 10V ±0.1% current 30mA and unregulated supply 24V
±10% current 50mA. Pressure switch status. Complete with a full range
of pressure connection adaptors. Record logging capability 444 and RS232
interface download to spread sheet files. Battery operation 10h or mains
operation via charger.

98
GENERAL INDUSTRIAL EQUIPMENT
Industrial Calibrators
SI PC6-PRO 350Bar Pressure Calibrator & HTP1 Hydraulic Druck DPI603 Pressure Calibrator 20Bar NATA Certified
Pump DRU,DPI603-20NA AU
SI,PC6-PRO 350 MY Includes pump for vacuum and pressure can display in 24 different units.
Range 0~350Bar. Measures 0~100mV (1µV resolution), 0~5V (0.1mV Interface ⅛”bsp. Accuracy 0.075%fs. Pumps 20bar pressure & -850mbar
resolution), 0~50V (1mV resolution) & current 0~50mA (1µA resolution) all vacuum. Measurements can be made to 20bar positive pressure & -1bar
@ 0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA (1µA vacuum. Unit has a 24V energising voltage. Monitor loop current to
resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1% current ±55mAdc @ ±0.075% reading & 0.005%fs. Monitor loop voltage to 50V @
30mA & unregulated supply 24V ±10% current 50mA. Pressure switch ±0.15% of reading & .02%fs. Unit is sealed to IP65. Battery life per charge
status. Pressure media oil, water & non corrosive gases. Battery operation is approx 40h (no 24V load)
10h or mains operation via charger. Complete with a full range of pressure Ambit Calibration Kit 20MPa
connection adaptors. AMB,CAL-20MPA AU
20MPa gauge with hydraulic hand pump, accuracy 0.5%fs.
SI PC6 700Bar Pressure Calibrator & HTP1 Hydraulic Pump
NATA Calibrated Druck DPI610HC 160Bar Pressure Calibrator
SI,PC6-700-NATA AU DRU,DPI610-160 AU
SI,PC6-700 MY Hydraulic pressure calibrator including pump and current voltage standard.
Range 0~700Bar. Measures 0~100mV (1µV resolution), 0~5V (0.1mV Pressure range 160bar ±0.025%fs. Voltage input ±50Vdc, ±0.05% reading
resolution), 0~50V (1mV resolution) & current 0~50mA (1µA resolution) all & ±0.004%fs. Current input ±55mA, ±0.05% reading & ±0.004%fs.
@ 0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA (1uA Temperature 10~40OC, ±1 (ambient) switch open/closed. Voltage output
resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1% current 10Vdc, ±0.1% or 24V ±5%. Current output 0~24mA, ±0.05% reading &
30mA & unregulated supply 24V ±10% current 50 mA. Pressure switch ±0.01%fs. Datalogger stores up to 10,000 values. mA ramp configurable.
status. Pressure media oil, water & non corrosive gases. Battery operation Pressure port G 1/8“(f). Pump includes screw adjustment.
10h or mains operation via charger. Complete with a full range of pressure
connection adaptors.
SI PC6 Pressure Calibrator & Pump 1000 Bar
> NEW Druck DPI610~20~NATA 20Bar Pressure Calibrator
NATA Certification
DRU,DPI610-20-NATA AU
SI,PC6-1000-NATA Pneumatic pressure calibrator including pump and current voltage standard.
Range is 1,000Bar. Nata calibrated Instrument. Measures Voltage 0~100mV Pressure range -1~20bar ±0.025%fs. Voltage input ±50Vdc, ±0.05%rdg,
(1µV resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) & ±0.004%fs. Current input ±55mA, ±0.05%, rdg ±0.004%fs. Temperature
current 0~50mA (1µA resoultion) @ 0.025% accuracy. Sources 0~10V -10~40°C ±1°C (ambient) switch open/closed. Voltage output 10Vdc ±0.1%
(0.2mV resolution) & 0~50mA (1µA resolution) @ 0.025% accuracy. or 24V ±5%. Current output 0~24mA ±0.05% rdg ±0.01%fs. Data logger
Voltage output regulated 10V ±0.1% current 30mA and unregulated supply stores upto 10,000 values. mA ramp configurable. Pressure port G ⅛f,
24V ±10% current 50mA. Pressure switch status. Pressure media oil and includes flexible hose kit. Pump includes screw adjustment.
water (unit can measure non corrosive gases but not pump them). Battery
operation 10h or mains operation via charger. Complete with a full range of
pressure connection adaptors.
SI Pressure HTP1 Pressure Pump
SI,HTP1 NZ
Hand operated hydraulic pressure pump, capable of 700bar. Quick priming
and pressure generation. High pressure/priming selector. Fine adjustment
control. Pressure release valve. Supplied with integral IANZ calibrated
digital gauge. Uses paraffin oil as the working fluid.
SI Pressure TP1-40 Pressure Pump
SI,TP1-40 NZ
Fully portable hand operated dual source of pneumatic pressure and vacuum.
Generates up to 40bar pressure or 96% vacuum. Adjustable stroke to
provide over pressure protection. Supplied with thread adaptors. Reference
gauge is required, see optional Fluke Pressure modules FLU,700Pxx.
Druck DPI603 Pressure Calibrator 10Bar NATA Certified
> NEW
Druck DPI610~20IS Pressure Calibrator
DRU,DPI610-20IS MY
DRU,DPI603-10-NATA AU
Ranges -1~20bar. Accuracy 0.025% fs all ranges. Integral combined
Displays in 24 different units. Interface ⅛”bsp. Accuracy 0.075%fs, includes pressure/vacuum pump. Dual readout: input & output. 4~20mA loop
pump for vacuum and pressure. Pumps to 20bar pressure & -850mbar test: auto step and ramp. RS232 interface and fully documenting version.
vacuum. Measurements can be made to 20bar positive pressure & -1bar Remote pressure sensors. Intrinsically safe version.
vacuum. Unit has a 24V energising voltage. Monitors loop current to
55mA dc @ ±0.075% reading & 0.005%fs. Monitors loop voltage to 50V @
±0.15% of reading & 0.02%fs. Unit sealed to IP65. Battery life per charge
is approx 40h (no 24V load).
Druck DPI603 Pressure Calibrator 20Bar
DRU,DPI603-20 AU/MY
Accuracy 0.075%fs. Pumps up to 20bar pressure & -850mbar vacuum.
Measures up to 20bar pressure & -1bar vacuum. In-built 24V energising
voltage. Monitors loop current to 55mA. Loop voltage to 50V. Interface
⅛”bsp. Battery operated.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 99
GENERAL INDUSTRIAL EQUIPMENT
Industrial Calibrators
Druck DPI610-2-NATA 2 Bar Pressure Calibrator
DRU,DPI610-2-NATA AU
Pneumatic pressure calibrator including pump and current voltage standard.
> NEW
Druck Loop Calibrator
DRU,UPS-3 AU
Pressure range -1~2bar, ±0.025%fs. Voltage input ±50Vdc, ±0.05%rdg, Measure and source 0~24mA, accuracy 0.01% of reading, dual mA and %
±0.004%fs. Current input ±55mA, ±0.05%rdg, ±0.004%fs. Temperature - readout, linear or flow. Step, span check, valve check, ramp. Measurement
10~40°C, ±1 (ambient) switch open/closed. Voltage output 10Vdc, ±0.1% or and continuity 60Vdc. HART compatible internal 235Ω loop resistor, menu
24V ±5%. Current output 0~24mA ±0.05% rdg ±0.01%fs. Data logger stores selectable. Large graphic LCD.
up to 10,000 values. mA ramp configurable. Pressure port G 1/8” (f), includes
flexible hose kit. Pump includes screw adjustment.

Ametek PPCE 700 Bar Pressure Calibrator


Druck DPI610-400-NATA 400 Bar Pressure Calibrator AME,PPCE-NATA AU/MY
DRU,DPI610-400-NATA AU High pressure calibrator with pump 700bar (10,000psi). Digital display with
DRU,DPI610-400 MY 5 digit resolution. Accuracy over 70bar ±0.07. Accuracy below 70bar ±0.35.
Hydraulic pressure calibrator including pump and current voltage standard. Current and voltage measurement ranges 4~20mA, 0~50mA & 0~30V.
Pressure range 0~400bar ±0.025%fs. Voltage input 50Vdc, ±0.05%rdg,
±0.004%fs. Current input 55mA, ±0.05%rdg, ±0.004%fs. Temperature Ametek Hydralyte HL2700N Dead Weight Tester
-10~40ºC ±1ºC (ambient) switch open/closed. Voltage output 10Vdc ±0.1% AME,HL2700N AU/MY
or 24V ±5%. Current output 0~24mA, ±0.05% rdg, ±0.01%fs. Data logger Dual range interchangeable piston:-100~4,500kPa, 0.5kPa increments,
stores up to 10,000 values. mA ramp configurable. Pressure port G 1/8” (f), 500~22,500kPa, 1kPa increments. Accuracy 0.05% of reading. Includes
includes flexible hose kit. Pump includes screw adjustment. special calculator for high accuracy pressure calculations and also
conversion of units.

Ultrasonic Baths
Soniclean 1000HT Ultrasonic Cleaning Bath Soniclean 2000HT Ultrasonic Cleaning Bath
SON,1000HT AU SON,2000HT AU
Tank size 495w x 295d x 150h mm includes heater and timer. Tank size 495w x 295d x 299h mm includes heater and timer.

100
GENERAL INDUSTRIAL EQUIPMENT
Environmental Test Chambers/Ovens
Model Type Temperature°C Humidity %RH Size (litres)
AES,LH-6 -20~94 20~98 150
ACS,CH160C Temperature & humidity chamber -70~180 20~95 178
ACS,CH340C -75-180 10-98 336
LAB,OTWMD18 30~200 66
Laboratory oven
MEM,ULE400 30~200 53
TEN,TJR Temperature chamber -80~200 33.6

> NEW
Angelantoni CH340 Environmental Temperature Chamber
ACS,CH340C AU
ACS Trolley for CH160C Environmental Chamber
ACS,TROLLEY AU
ACS Winkratos Software for CH160C Temperature & Humidity
Temperature range -75~180ºC, humidity range from 10~98% RH in the
Chamber
range of 10~80ºC, dew point range 2~94ºC for continuous tests. Relative
ACS,WINKRATOS AU
humidity accuracy ±1%~±3%. Capacity 336lt. Internal 600w x 800d x 700h
Software for remote control of ACS,CH160C temperature and humidity
mm. External dimensions 850w x 1725d x 1516h mm. Control by uPLC &
chamber. Remote programming and control of chamber plus report
graphical control panel on the door. Program temp & RH cycles and control
generation. Includes Compaq Armada E500 Pentium III 500MHz notebook
all chamber functions and alarms. Entry port, door with inspection window,
computer & RS232C interface cable.
internal lighting, 1 shelf, RS232C interface. Electrical rated power 5.7kW,
maximum used power 9kW. Voltage 400 +6%, -10%, 50Hz, 3ph. Noise Memmert ULE400 Laboratory Oven
63dBA , weight 750kg approximately including transit case. MEM,ULE400 AU
Range 30~220OC. Capacity 53L, internal 400w x 400d x 330h mm. Two
shelves. Electronic temperature control with max deviation of 0.8~4OC.
Labec OTWMD18 Laboratory Oven
LAB,OTWMD18 AU
Fan forced laboratory oven, ambient to 200OC. Capacity 66L, digital
temperature controller.
Tenney TJR Environmental Temperature Chamber
TEN,TJR AU
Range -80~200OC. Workspace 400w x 280h x 300d mm. In transit case
1350w x 720d x 1050h mm. Operates in case with lid off. Programmable
controller 24 step display resolution 1OC. Heating rates 25~100OC, 15min
or 25~200OC, 55min. Cooling rates 25~-40OC, 20min or 25~-80OC, 65min.
Access port 50mmØ.

ACS CH106C Temperature & Humidity Environmental Chamber


ACS,CH160C AU
Temperature range -70~180ºC, humidity range from 20~95%RH in the range
of 10~80ºC, dew point range 5~79ºC for continous tests. Realtive humidity
accuracy ±1%~±3%. Useful capacity 178L, internal 560w x 564d x 560h
mm. External dimensions 760w x 1115d x 1370h mm. Control by micro
PLC and control panel placed on the door (4 lines alphanumeric display and
keyboard). PLC programs Temp & RH cycles and to control all chamber
functions and alarms. Entry port 80Ømm, door with 230 x 230mm window,
internal lighting, 1 shelf, RS232C interface. Dissipation at -55ºC,100W.
Electrical power 4.5kW (average 3.3kW). Voltage; 230V +6%, -10%, 50Hz,
1ph. Noise 60dBA measured at 1m from the front in a non reverberating
room. Weight; 390kg (excluding transit case).

AES LH-6 Temperature Humidity Chamber


AES,LH-6 NZ
Internal dimensions 610w x 510d x 480h mm. External dimensions 1170w x
840d x 790h mm. Operating range temperature -20~94OC, ±0.5 at sensor.
Humidity 20~98%RH ±2% at sensor. Includes self contained humidity system,
200 x 200mm window, access port, microprocessor controller and high/low safety
shut down.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 101
TEMPERATURE & HUMIDITY MEASUREMENT
Temperature/Humidity/Barometric Recorders
Kane-May KM1242 5 Channel Indicator & Recorder Micromech MM-01 Thermohygrograph
KM,KM1242 AU MIC,MM01 AU
Five channel temperature indicator and recorder. Range -100~1300OC, Recording ranges -10~50OC & 0~100%RH. Specify 7d or 24h charts.
resolution 0.1. Uses type K thermocouples. Gives average, max and min
Hobo Pressure Logger
for period recorded. Operates from NiCd batteries or ac adaptor.
HOB,PRES AU
Hanna HI98704, 4 Channel Thermocouple Printer Range 0.5~16psia. Safe operating temp range -39~75OC. Size 46w x 148d
HAN,HI98704 AU x 15hmm & 255g. Stores 1,800 measurements, 42 preset intervals. Data
Four channel thermocouple input temperature display and printer. Accepts can be exported to spreadsheet. Logs in meters, feet, mbar and Hg. Battery
all common thermocouple types including K & T. life 2y.
Haenni KRK Thermohygrograph Dickson PR500 Pressure Logger
HAE,KRK501 MY DIC,PR500 NZ
Temperature -10~50ºC. Humidity 0~100%. Accuracy, thermograph ±1%fs, Records pressure in water and gas lines. Compact size is perfect for tight
hygrograph: ±4%fs. locations. Water resistant stainless steel case for use for outdoor applications.
Pressure range is 0~500PSI, accuracy is ±1% of full scale. Stores 7936 data
points. Programming and data recovery done by TechRentals.

Temperature Meters/IR Thermometers


Temperature Type Type J, T, E, N,
Model Type Output Ratio
Range ºC K R, S
ANA,AN2406 Precision RTD thermometer -20~200 Serial & analogue RTD RTD
FLU,52-2 Digital thermometer IR cxommunication port Yes
FLU,54 Logging with IR interface
FLU,54-2 RS232 Yes
Dual channel digital logging thermometer -250~1,767 2 Ch
FLU,54Flukeview IR interface & software
FLU,54-2Flukeview Logging with IR interface USB
Photo temperature Infrared thermometer with
FLU,576 -30~900 USB or 1mV/ºC 60:1 No
built in camera
FLU,80PK3 Type K surface probe Probe
FLU,80TK Type K transducer Analog out Yes
HAR,1521-NATA Precision thermometer NATA -200~420 RS232
No
MIC,M90H IR thermometer, high temperature range 600~3,000
180:1 No
MIC,M90Z IR thermometer, narrow field of view -50~1,000 Analog out & RS232
RAY,MX4+ IR thermometer laser sighted 60:1
IR thermometer laser sighted plus digital -30~900 1 Ch
RAY,MX6 Analog & USB 60:1
camera
Infrared thermometer with humidity probe and
TES,845 -35~950 USB 75:1 Yes
thermocouple probe

> NEW Fluke 576 Photo Temp Infrared Thermometer with


Built-in Camera
> NEW
Fluke 52-2 Digital Thermometer
FLU,52-2 MY
FLU,576 AU/MY
Relative time clock on MIN, MAX, and AVG provides a time reference
Range -30~900ºC. Minimum measurement 19mmØ, laser class II, 3 point
events. Electronic Offset function allows compensation of thermocouple
spot. Includes adjustable emissivity from 0.1~1 by 0.01. Target size 1/60 of
errors to maximize overall accuracy . Measures J, K, T, & E-types of t/c.
distance. Max, min, dif and av displayed on backlit lcd with bar graph. Data
Readout in ºC, ºF, or Kelvin (K). Battery life: typical 1000h. Battery door
output USB or 1mV/ºC, windows software and cable included. Accuracy
allows easy replacement without breaking the calibration seal. Large backlit
±0.75% of reading or ±1ºC which ever is greater. Response time 250ms.
dual display shows any combination of T1, T2, T1-T2 plus MIN, MAX, or
Display resolution 0.1ºC. Continuous measure mode.
AVG. Additional t/c type R, S, & N (a total of 7 types). Recall function allows
logged data to be reviewed on the display. IR communication port allows
data to be exported to optional FlukeView Forms® Temperature PC software
for further analysis and graphing. Data Logs up to 500 points of data with
user adjustable recording interval.

102
TEMPERATUIRE & HUMIDITY MEASUREMENT
Temperature Meters/IR Thermometers

> NEW Testo 845 IR Thermometer With Humidity Probe and


T/C Probe
TES,845 AU
Raytek MX4+ Infrared Thermometer
RAY,MX4+
Range -30~900OC. Size of measurement target is indicated by lasers.
AU/NZ

Range -35~950ºC with built in humidity probe, range 0~100%RH. Instrument includes Type K t/c for additional temperature measurement
Switchable distance ratio far field 75:1 16mm, distance 1200mm, close to set emissivity. Target size 1/60 of distance. Built in emissivity table,
focus 1mm, distance 70mm. Laser class II, 4 point spot/cross far field, 2 audible/visible high low alarm. Max, min, dif and ave display. RS-232 and
point/1point close focus. Includes adjustable emissivity from 0.1~1, max, analog output, windows software and cable included. Accuracy ±1%, ±1OC.
min, displayed on backlit LCD . Data output USB windows software and Response time 250m/s. Display resolution 0.1OC. Continuous measure
cable included. Accuracy ±0.75% of reading 100~950ºC. Display resolution mode.
0.1ºC. Continuous measure mode. Plug in T/C probe supplied.

Fluke 54 Dual Input TC with Logging Raytek MX6 Photo Temp Infrared Thermometer, Built in Camera
FLU,54 AU RAY,MX6 AU/NZ
Digital thermometer with data logging. Takes most t/c inputs. Accuracy Range -30~900ºC with built in digital camera. Min measurement 19mmØ,
±0.05% +0.3OC. Logging 500 points with date and time stamp. Records laser class II, 16 point circle spot. Includes adjustable emissivity from 0.1~1.0
min, max or avg. Logged data can be reviewed on meter or downloaded via x 0.01. Target size 1/60 of distance. Max, min, dif and av display with backlit
IR port (see FLU,54FLUKEVIEW). lcd with bar graph. Data output USB or 1mV/ºC, windows software and
cable included. Accuracy ±0.75% of reading or ±1ºC which ever is greater.
Fluke 54-2 Dual Input TC Response time 250m/s. Display resolution 0.1ºC. Continuous measure
FLU,54-2 AU mode. Digital camera and flash built in.
D series 2, dual input digital thermometer with data logging. Takes J, K, T,
E, R, S, N T C inputs. Accuracy ±0.05%+0.3OC. 500 point logging with date
and time stamp. Records min, max or avg. Logged data can be reviewed
on meter or downloaded via IR port (see FLU,54FLUKEVIEW : Fluke 54 with
IR/RS232 cable & Flukeview software or FLU,54-2FLUKEVIEW : Fluke 54-2
with IR/RS232 cable & Flukeview software).
Fluke 54 Dual Input TC with Flukeview Logging Software
FLU,54FLUKEVIEW AU
Specification as above. Logged data can be reviewed on meter or
downloaded via IR port using cable and Flukeview software included.
Fluke 54-2 Dual Input TC with Flukeview Logging Software
FLU,54-2FLUKEVIEW AU
Series 2, dual input digital thermometer with data logging. Will take most TC
inputs. Accuracy ±0.05% +0.3ºC. 500 point logging with date & time stamp.
Also records min, max or avg. Logged data can be reviewed on meter Micron M90H Infrared Thermometer
or downloaded via IR port RS232 interface, (using cable and Flukeview MIC,M90H AU
software included). Range 600~3,000OC. Focusing 500mm to infinity. Field of view for
measurement 1:180 (1/3O). Resolution 1OC. Accuracy 0.4% of reading.
Hart 1521 NATA Precision Handheld Thermometer Recorder output 1mV/OC. RS232C interface. Battery operated.
HAR,1521-NATA AU
Accuracy 0.025ºC. Includes 5614 probe ¼”Ø x 12” long. Calibrated in the Mikron M90Z-B Infrared Thermometer
-183~500ºC range. Probe operating range -200~420ºC (cable and transition MIC,M90Z AU
to 150ºC max). Features through lens sighting and sharp focusing. Temperature displayed
in view finder. Data hold, peak valley and average functions. Temperature
Analogic Precision RTD Thermometer range -50~1,000OC. Accuracy 1%, 1OC. Field of view for measurement
ANA,AN2406 NZ 1:180. Rechargeable NiCd batteries give 8h life.
Range -20~200ºC accuracy is ±0.1, resolution is 0.01. Supplied with a
calibrated probe of 150mm x 6mmØ. Serial and analogue outputs. AC or
battery operation.
CHY 505 Portable Digital Reference RTD Thermometer
CHY,505 NZ
Portable digital reference rtd thermometer. Range is -25~250ºC, resolution
is 0.1, accuracy including probe ±0.05% of reading 0.3ºC. Supplied with
PT385 RTD probe (length 150mm x 3mmØ) and IANZ endorsed calibration
certificate.

Fluke 80TK Thermocouple Module


FLU,80TK AU
Use with DVM’s and recorders. Accepts K thermocouples. Temperature
range -50~1,000OC. Output 1mV/OC. Type 80KP-1 probe included.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 103
TEMPERATURE & HUMIDITY MEASUREMENT

Thermal Imaging Cameras


Marconi Argus2 Black & White Thermal Camera
MAR,ARGUS2 AU
Gives live thermal image, quick and clear image. Good for fast assessment.
> NEW
Flir InfraCAM thermal Imaging Camera
FLI,INFRACAM au
Applications include general industrial work, electrical work, surveillance Simple to use battery operated real time thermal imaging camera. In-built
work and termite inspection. Displays temperature in the centre of image. 3.5” colour LCD, detector resolution 120 x 120. Ranges, spectral 7.5~13µm,
If the image needs to be recorded you can use the NOG,USBVIDEO or temperature -10~350ºC, accuracy ±2 or ±2% of reading. Imaging frame rate
the Cannon MV400i and use the analog video in (The ARGUS2 video out 9Hz, video output via USB interface, stores 50 images. Down load to PC via
is an NTSC signal). The accuracy of the temperature measurement is USB. Operating range -15~50ºC. Supplied with Quickview s/w and digital
±2OC or ±2% and the range is 0~500OC ±2 or ±2%. Ambient temperature camera. Fixed spot on LCD, maximum 3 spots via software.
measurement is ±2OC or ±5%. Display indicates a temperature difference
of 0.1OC. Uses the 0.8~14µm thermal range. Dust and water proof to IP67.
Battery life is 120min per battery (4 supplied).
ISI 525 Snapshot Thermal Camera
ISI,IR777 AU/NZ
Uncooled thermal imaging system with a 4” high resolution TFT LCD display
which captures and stores an image to a PCMCIA card. A cursor on the
display can be driven to any point on the image and a temperature at that
point read out. Measurement range is 0~350OC. PAL video output. In-built
PCMCIA card stores 72 images.
External Battery Pack for ISI,IR777 Thermal Imaging Camera Flir Systems E45 ThermaCam Thermal Imaging Camera
ISI,BATTPACK-EXT AU FLI,E45 AU
Optional sealed lead acid battery pack for ISI,IR777 Thermal Imaging In-built 2.5” colour LCD, detector resolution 160 x 120. Ranges, spectral
Camera. Battery capacity 10Ah, includes carry case for battery with shoulder 7.5~13µm, temperature -20~250OC, accuracy ±2 or ±2% of reading.
strap, smartcharger and special connector with 2m of connection cable. Imaging frame rate 50Hz, video output standard RCA composite video,
stores 200 images, image run or freeze. Download to PC via USB. Operating
range -15~45OC. Supplied with download software and Panasonic digital
camera. Single moveable spot for temperature measurement. Built in tripod
mounting, 1/4”-20.

104
TEMPERATUIRE & HUMIDITY MEASUREMENT
Thermal Imaging Cameras
SAT S160 Real Time Thermal Imaging camera SAT Tripod Fitting Adaptor For SAT S160 Camera
SAT,S160 AU/NZ SAT,TRIPOD-FIT au
With 2.5” colour LCD, detector resolution 160 X 120. Ranges, spectral Tripod fixture clamps around the SAT,S160 thermal imaging camera and
8~14µm, temperature -20~250OC ±2 or ±2%. Imaging frame rate 50Hz, then allows this camera to be mounted on a tripod.
video output PAL, image storage 500 pictures, image run or freeze. Image
download to PC via USB. Ambient operating range -15~50OC. Supplied with
download software and Panasonic DMC-FZZA digital camera.

Humidity & Moisture Meters


Model Type Features
PAN,PM880 Industrial Moisture Analyser Intrinsically safe
PAN,MMS35 Moisture meter for air & nat gas Moisture content under pressure
PRO,SM* Concrete & timber moisture meter Two pin inspection mode & RF mode
PRO,CMIII* Concrete moisture meter Gel conductivity & standard surface humidity test

*See Concrete Testing Equipment

Panametrics MMS35 Air/Natgas Moisture Analyser


> NEW
GE Panametrics PM880 Industrial Moisture Analyser
PAN,PM880 AU
PAN,MMS35 AU
Intrinsically safe for compressed air systems and hydrocarbons such as
Intrinsically safe moisture analyser for compressed air systems, non- natural gas. Displays dew point & ppm moisture by volume. Pressure
corrosive gases & hydrocarbons such as natural gas (IS certification to set as a constant. Data logging with RS232 port for download. Operating
ATEX and CSA). Displays dew point, moisture concentration, pressure & temperature range -110~70OC. Pressure range 5µHg~5,000psig. Accuracy
temperature. Dew point calibrated measurement range -80~20°C with data 60~-60OC ±2, -66~-110OC ±3. Repeatability: 60~-60OC ±0.5, -66~-110OC
to -110°C. Pressure range 7~69bar limited by sensor, gauge and safety- ±1. Response time <5s for 63% step change. Gas flow range from static to
valve (operating range from 5µHg). Temperature range -30~70°C. Gas flow 10,000cm/s velocity @ 1atm.
operating range from static to 10,000 cm/sec velocity. Supplied with compact
sample system with gauge, safety-valve, sampling valves and fittings (¼”
Swagelok). Data logging of up to 100K moisture points, with infrared port
and software for download. Battery powered only (15-24h operation) with
second battery and charger (note charger is not IS).

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 105
SECURITY EQUIPMENT
Security Equipment
Detec DH50 Hand-held Metal Detector AVE Serial to Video Converter Including Video Mixer
DET,DH-50 AU AVE,VSIPLUS AU
Simple to operate, no adjustment needed. Audible alarm. Mixes serial data (text) with video signal, so that a picture includes this text.
Use with a GPS (eg GA,ETREX) to add a location reference to a video or
used with cash register RS232 output to record transactions on a security
camera picture.
Elbex 1-Camera VCR Surveillance System
ELB,CCTV2 AU
Single camera time lapse video recorder. Uses pin hole camera and 24h time
lapse VHS VCR. VCR can accept an alarm input from a motion detector, etc
and this will provide a time stamp and trigger a period of real time recording.
Camera lens 8.5mm giving 70O field of view. Video monitor included.
Poptron CCD RF Camera and Receiver IR Lighting
POP,RF-CCD AU
Video surveillance camera with radio frequency link. Transmits video &
audio from a camera 30m~100m depending upon conditions (900~930MHz
Detec DH50 Hand-held Metal Detector Kit of 4 carrier). Standard video & audio output. Infrared illuminator included - range
DET,DH-50-KIT4 AU
1.5m.
Kit of 4 x hand held security metal detector. Simple to operate - no adjustment
needed. Audible alarm. Optalign RF Transmitter Detector System
OPT,BUG AU
Radio transmission detector system useful for ‘bug’ detection and nearby
transmission interception. Comprises 3 principal units R10 FM interceptor
which auto tunes to a near field transmitter - range 120m typical for 5W
VHF/UHF. In-built speaker and deviation indicator. Frequency range
30MHz~2GHz. R20 AM interceptor with headphone output. Frequency
range 500kHz~2.5GHz. Signal strength bar graph. Scout 40 frequency
counter for off air frequency indication of near field transmissions. In-built
logging permits a walk through surveillance of an area. Accessory antennas
are included to optimise reception. An optional PC package permits long
term surveillance - see separate model.
Optalign Optalog Scanning Software
Garrett CS5000 Walk Through Metal Detector OPT,OPTOLOG AU
GAR,CS5000 AU PC interface and software for OPT,BUG Scout 40 frequency counter.
Detects all metals. Requires assembly on-site & set-up. Adjustable
Pacom 8 mm Colour Camera, Auto Iris, 6~15mm Lens
sensitivity.
CAM,COL-AUTO AU
Colour surveillance camera 8mm CCD auto Iris 6~15mm lens.
4 Camera Surveillance Digital Stand-Alone Record System
CAM,DVMR-4C AU
4 day/night colour cameras with stand-alone digital video multiplex recorder,
complete system with 15” colour LCD screen, 20m connection cables, power
supplies and video to USB coverter for down loading of data to PC.

Garrett Superscanner Hand-held Metal Detector


GAR,SUPERSCANN AU
For security applications.
Swise Surveillance Digital Camera
SWI,COLOR AU
Captures up to 700 images. Includes motion detector, only takes images of
changes. Can be connected to a modem to dial and transmit the images.
Contact input which activates dialing so it could be connected to a DataTaker
for dial out alarms. Includes software and cable to download the images
to a PC directly or via a modem. Will not operate until powered. When
finished, will not operate after power down. System can be configured and
downloaded by TR Services (please request quotations). System draws
120mA @ 12V, operates for 3d on 10Ahr 6V batteries, or for 6d on 8 alkaline
D cells or 9d on 2 lantern batteries.

106
SECURITY EQUIPMENT
Metal Detectors
Pulse Technology AQ-1B Underwater Metal Detector
PUL,AQ-1B AU
Suitable for above ground use also. Hand-held, battery operated, complete
with high sensitivity 15” search coil, compact 8” coil, and small ferrite probe.
Supplied with a bone conduction phone for underwater use and headphones
for above ground use. Complete with charger.
Minelab SD2000 Gold Prospecting Metal Detector
MIN,SD2000 AU
Designed primarily for gold prospecting. Kit includes 2 search heads, battery
and 240V and in-car battery chargers. Incorporates multi-period sensing
(mps), allowing the unit to operate in highly mineralized soils (it will detect
nuggets at 2~4 times the depth of a typical metal detector). Battery life

>>Did you know…. 16h.


Cscope CS550 General Purpose Metal Detector
CSC,CS550
Simple to use and light weight. Ideal for locating rings, etc. Works well in
AU

We have over locating metal underground services.


Excaliber 1000 Under Water Metal Detector
10,000 items of EXA,1000 AU

specialised MIN,EX-1000 MY
Search coil 10”. Use effectively in or out of the water. Features 2 operating

technical modes all metal and discriminate. In discriminate mode, ignores most
ferrous objects and still detects the valuable non-ferrous objects such as

equipment in our gold and silver. Rechargeable battery pack separated from the electronics
cylinder allows easy access for recharging.

inventory, so
we’re bound to
have a solution to
Retail Traffic Flow Counters
virtually any test
and measurement Traffic Pro People Counter Event Logger
TRA,RETAILPACK AU

problem. Counts the number of people passing a particular point. Used to check the
success of in-store promotions, counting people entering sections of a store,
etc. The unit operates from internal batteries and will store one years worth
of data at a 1h sample rate.
To see our full
range visit our
websites and
don’t forget
to register for
new product
releases too.

www.techrentals.com.au
www.techrentals.co.nz
www.techrentals.com.my

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 107
>>Did you know….
TR Corporation
has 30 locations
across the Asia
Pacific region,
so its never been
easier to rent
your test and
measurement
needs from us.

Visit our websites


for contact
details.

www.techrentals.com.au
www.techrentals.co.nz
www.techrentals.com.my
ENVIRONMENTAL
FLOW METERS
FLOW METERS - LIQUID

Model Type Features Max Flow Temp °C Pipe Ø mm Major Application

Data logging
PAN,PT868 RS232C Liquids, Energy flow
Ultrasonic 4~20mA Low gas/solids content
Transit time ~12m/s -20~150 50~2,000
Pipes (clamp-on)
Non-contact Data Logging Note: NATA versions available
PAN,PT878 IR interface
Large LCD
PAN,C-LP-40NM -40~120 12~50 Small diameter pipes
Transducer set,
PAN,C-PT-10HB -20~210 50~2,000 Wide temperature range
PT868/878
PAN,OKS -200~400 80~600 Very wide temperature range
PAN,2CHRT-1-1 Temperature sensors, -20~130
Clamp-on
PAN,2CHRT-1-2 PT868/878 -20~260
Software PT868 &
PAN,SOFTWARE Storage, Recall, Download
PAN,MMS35
Ultrasonic Dual frequency Liquids, Slurries
POL,HYDRA-SX30 Doppler Data logging 10m/s -40~122 12~5,000 High gas/solids content
Non-contact RS232C, 4~20 mA Pipes
Log rate 5s –1 week
UNI,6526B-21
Flow/Depth/Temp
Liquids, Slurries
Ultrasonic
~5m/s -0~60 Open Channel
Doppler Log rate 5s –1 week
Logging System
UNI,6526B-21LCD Flow/Depth/Temp
LCD display

Stainless fan
Propeller flow counter with Water Current Measurements
HYS,OSSB1 Adjustable depth 5m/s
field-computer Hydrology
storage & download

Telescopic handle
5cm min Rivers & streams
GLO,FP101 Propeller flow counter Velocity averaging 4.5m/s
depth Irrigation channels
Digital counter

Global FP101 Digital Water Velocity Meter Panametrics Software for PAN,PT868 & PAN,MMS35
GLO,FP101 AU PAN,SOFTWARE AU
Portable flow probe - current meter for water velocity measurements in Software for PAN,PT868 flowmeter and PAN,MMS35 moisture analyser.
streams, channels and partially filled pipes. Propeller sensor in 50mmØ Allows storage, recall and download of instrument setup routines. Versions
housing, fitted to telescopic handle [1.8m] with gauging marks to 900mm available to match instrument firmware revisions.
depth. Digital LCD flowmeter display for instantaneous liquid velocity and
average, maximum, stopwatch or clock. Minimum depth about 50mm. Panametrics PT868 Flowmeter NATA Certification
Range 0.1~4.5m/s ±0.05. PAN,PT868-NATA AU
Specification as for PT868 above but NATA certification.

Panametrics 12~50mm Transducers


PAN,C-LP-40NM AU/MY
Transducer pair for PAN,PT868/878 transit-time flowmeter to suit pipe
12~50mmØ. Complete with CF-LP-50M mounting bracket. Temperature
range -40~120OC.

Panametrics -20~210OC Transducers


PAN,C-PT-10HB AU
High temperature transducer pair for PAN,PT868/878 transit-time flowmeter.
Operates on pipe sizes 50mm~2mØ. Working temperature range -
20~210OC.

Panametrics -200~400OC Transducers


Panametrics PT868 Ultrasonic Flowmeter PAN,OKS AU
PAN,PT868 AU/NZ Very high temperature, wide range transducer pair for PAN,PT868/878 transit-
Portable non-contact liquid flowmeter using transit-time principle. Includes time flowmeter. Temperature range -200~400OC, for pipe 80mm~600mmØ.
transducers for pipe diameters 50mm~2m and temperatures -20~150OC Uses special clamp system supplied. Appropriate protection and safe-
[additional transducers available] with clamping fixture. Flow velocity range handling equipment is required for fitting and operation at very high or low
0.03~12.2m/s. Accuracy typically 1%. Data logging capacity. Analog [current temperatures.
loop] and RS232C outputs, and analog inputs compatible with temperature
transmitters for energy-flow calculations. Totalised flow and trend analysis.
Rechargeable NiCd operation for 8~10h or operation from ac mains or
external dc 10~28V supply.

110
FLOW METERS
Flow Meters - LIQUID
Panametrics PT878 Ultrasonic Flowmeter Panametrics 2-CH RTD TX for PT868/878 Energy Calcs
PAN,PT878 AU/MY PAN,2CHRT-1-1 AU
Portable non-contact liquid flowmeter using transit-time principle. Includes Two channel 4~20mA RTD transmitter, range -20~130OC for energy rate
transducers for pipe 50mm~2mØ & temperatures -20~150OC (various and consumption measurements with PAN,PT868 or PAN,PT878 ultrasonic
alternative transducers available) with clamping fixture. Flow velocity range flowmeters. Provides supply and return temperatures for flowing liquid.
0.03~12.2m/s. Accuracy typically 1%. Data logging for over 10K data Panametrics cable and connector supplied. Fitted with pair of clamp-on
points. Analog inputs compatible with temperature transmitters for energy- Pt100 RTDs and cables. Powered from flowmeter.
flow calculations. Outputs analog 4~20mA, digital (pulse or frequency) and
Panametrics 2-CH TX for PT868/878 Energy Calcs
printer/computer (Infrared port). Large LCD display for velocity, volumetric
PAN,2CHRT-1-2 AU
and energy flow rate, totalised flow and trend data in alphanumeric and
Two channel 4~20mA RTD transmitter, range -20~260OC for energy rate
graphical formats. Rechargeable NiMH batteries and ac power supply/
and consumption measurements with PAN,PT868 or PAN,PT878 ultrasonic
charger.
flowmeters. Provides supply and return temperatures for flowing liquid.
Panametrics cable and connector supplied. Fitted with pair of clamp-on
Pt100 RTDs and cables. Powered from flowmeter.

GE Panametrics PT878 Flowmeter with NATA Certification


PAN,PT878-NATA AU
Specification as above but with NATA certification.
Polysonics Hydra SX30 Dual Frequency Doppler Liquid
Flowmeter Unidata Open Channel Liquid Flow Logger with LCD module
POL,HYDRA-SX30 AU
UNI,6526B-21LCD AU
Ultrasonic non-contact flowmeter. Velocity range 0.06~10m/s, accuracy
Open channel flow logger with field LCD display module and 10 m cable
±1%. Pipe size range 12mm~5mØ. Data logging for 90,000 points, with PC
(2m depth rating). Measurement and logging of flow-velocity (by Doppler),
software and interface cable for download via RS232C interface. Transducer
depth (by pressure) and temperature. Programmable for flow-channel
temperature range; -40~122OC. Analog output 4~20mA. Battery operated,
profile (laptop PC required for in-situ programming via RS232C). Operating
12h continuous use [8h recharge].
temperature range 0~60OC. Velocity 21~5,000 mm/sec +/-2%; depth
0~2,000 mm +/-2%. Temperature: -17~60OC +/-0.1; log-interval 5 sec~1
week; memory 120k. Programmable output to control devices such as water
samplers. Detects and measures reverse flows. Charger and batteries
supplied. Workhead dimensions 290 x 70 x 25mm.

Hydrological Services Universal Current Meter OSS-B1


HYS,OSSB1 AU
Water current meter for measurement of flow velocity in rivers, streams,
channels and open water. Robust streamlined stainless body fitted with high
precision 100mmØ fan [flow range 0.025~5m/s]. Set of stainless wading rods
for depths to 3m. Rechargeable “Hydromate” ruggedised field computer with
IP65 case. Storage of fan calibration formulae for direct readout of volume-
flow. Touch screen entry for set up, input, storage and download. Supplied
with PC download software and cable.

Unidata Open Channel Liquid Flow Logger


UNI,6526B-21 AU
Open channel flow logger, programmed in-situ for flow-channel profile
(laptop PC required). Measurement of flow-velocity (by Doppler), depth (by
pressure) and temperature. Includes 10m cable. Memory 120k, RS232
interface. Log rate 5 sec~1 week. Operating temperature range 0~60OC.
Velocity 21~5,000mm/sec +/-2% (resolution 1); depth 0~2,000mm +/-2%
(resolution 2). Temperature: -17~60OC (resolution 0.1). Programmable
output to control devices such as water samplers. Detects and measures
reverse flows. Charger and batteries supplied. Workhead size 290 x 70 x
25mm.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 111
FLOW METERS
FLOW METERS - gas
Temp Pipe Ø Major
Model Type Features Max Flow
°C mm Application
4 ~ 20mA output Air under pressure
SPI,VFM5000-50 Vortex 600m3/h Supplied DN50
Flow, Pressure, Temperature Saturated steam
~200ACFM
HOF,2000 & HOF,38 Turbine flowmeter Totalising recorder outputs 38mm or 50mm turbine Gases
(50mm)
Mass-flow thermal “Dial-A-Gas” for 10 gases
SIE,S100-5 5slpm ¼” (at meter) Low – flow gases
sensor RS232C, Analog outputs
Thermal mass-flow Cold tap fittings, RS232C
KUR,2443-24 12,000sfpm -40~200 50mm~ Gases
insertion meter Logging, 4 ~ 20mA output
Insertion Hot-tap rig ~150mm
PVL,CLIMA3 40m/s -20~80 Compressed air
micro-turbine RS232, Pressure transducer (450mm without hot-tap)
Mass-flow thermal Temp measurement Clean air flow
TSI,4143-6 0.01~20slpm In-line 9.5mm
sensor RS232C, Mains/battery Use as calibrator
0~50
Mass-flow thermal Temp measurement Clean air flow
TSI,4040-6 ~300slpm In-line 22mm ISO
sensor RS232C, Mains/battery Use as calibrator

ClimaAir 3 Flow Meter for Compressed Air & Gases Portable Mass Flowmeter & Calibrator 0.01~20 SLPM
PVL,CLIMA3 AU TSI,4143-6 AU
Portable gas flowmeter for compressed air and other applications. Fitted Thermal mass flowmeter or field calibrator for operation in the range
with “Combisensor” insertion probe for simultaneous measurement of flow, 0.01~20SLPM (standard litres/min). LCD display for flow, temperature and
pressure and temperature. Measuring ranges flow 0.06~40m/s, pressure pressure . For flow measurements on clean air, or for calibration checks on
to 15Bar, temperature to -20~80ºC. Supplied with valve and adaptor-kit for personal sampling pumps. Accuracy ±2%/0.005SLPM [whichever is greater]
hot-tapped pipes approx 25~150mm ID, and fitting-kit for pipes to 450mm. for air or oxygen (±3%/0.010SLPM for nitrogen or air-mixtures). Operating
Flow computer functions include flow correction, volume-calculation, and pressure range 50-199kPa absolute [approx 95kPa gauge]. With HEPA filter,
data logging for about 15,000 values. With RS232 interface and cable, and adaptors and tubing. RS232C/analog connector with cables supplied. AC
software for data download. Rechargeable with AC adaptor. adaptor or battery operation.
Hoffer 2000 Gas Flow Meter Indicator
HOF,2000 AU
Flow indicator/totalizer for use with flow transducers. Digital display with
recorder outputs 0~10V, 4~20mA. RS232C interface. Operates from ac
mains. Display of metric units with optional conversion factor.
Hoffer 38mm Gas Flow Turbine/Transducer
HOF,38 AU
38mm MS flared gas flow turbine/transducer for use with HOF,2000.
Volumetric flow rate range 1.75~120 actual cfm - gas type, pressure and
temperature correction may be used for mass flow units such as SCFM,
kg/min or L/s. Supplied with 38mm Table E Flanges. Approach pipe length
Sierra Series 100 Gas Mass-flowmeter 0~5l/min 380mm, exit pipe length 190mm.
SIE,S100-5 AU
Kurz 2443 Air Velocity Meter
Smart-Trak mass flowmeter. Digital display of mass flow rate for gases
KUR,2443-24 AU
in the range 0~5l/min. Dial-A-Gas set up for direct readout of flow for 10
Portable air velocity meter and flow-computer. Velocity range 0~12,000sf/min
different common gases without adjustment or recalibration. Analog and
(60m/s) at pressures to approx 10bar (probe rated to 20bar). Temperature
serial RS232 ports, with software and cable provided for connection to PC.
range -40~200OC with compensation. User selected English or metric units
Portable configuration with case, battery, ac power supply and flexible gas
for velocity or mass-flow. Thermal sensor probe 9.5mmØ & 330mm long
connection set.
with sensor-shield, with compression fitting and nylon ferrules for probe
Portable Mass Flowmeter & Calibrator 0~300 SLPM removal or position adjustment in tapped pipe. Suitable for use in ducts or
TSI,4040-6 AU pipes, min pipe 50Ømm. Calibrated for air, and suitable for use with other
Thermal mass flowmeter or field calibrator for operation in the range non-hazardous gases. Recording of up to 1,500 data sets with time and
0~300SLPM (standard litres/min). LCD display for flow, temperature and date. Two analog 4~20mA outputs, and RS232C serial port for configuration
pressure . Suitable for flow measurements on clean air, or for calibration upload and data download. Rechargeable NiMH batteries.
checks on personal sampling pumps. Accuracy ±2%/0.05SLPM [whichever
is greater] for air or oxygen [±3%/0.10SLPM for nitrogen or air-mixtures].
Operating pressure range 50-199kPa absolute [approx 95kPa gauge]. With
HEPA filter, adaptor and tubing. RS232C/analog connector with cables
supplied. AC adaptor or battery operation.

112
AIR CONDITIONING & AIR QUALITY - HVAC & IAQ
Air Flow Measurement/Air Quality

Model Air Velocity Flow Max


Type Pressure Functions Notes
m/s l/s Temp OC
SHO,CFM88-3 12~944
Balometer
TSI,8373 Logging
TSI,8370 15~1,000 60
TSI,8371
0.13~41 Hood
Accubalance modular air ±3735Pa diff
TSI,8375 depending on 11~1,000 Logging Pitot
balancing tool 135 kPa abs
probe Velocity Matrix
125 Pa
~14
AIR,EDM2500 500 Pa Recorder output
~28
2,500 Pa
DRU,DPI705
0~20 kPa Analog output
HAL,EMA150 Manometer (electronic)

SHO,ADM-860 ~50 0.025~14,700Pa With Velgrid


Logging
TSI,8704 1.25~78.5 -1245~3735Pa
RS232C

AIR,DM2 ±200kPa Recorder output

Pressure:
199.9Pa
DPM,TT370S 1.2~100 Without Pitot tube
Manometer (digital) 1999Pa
7.0kPa
Pressure:
99.9Pa
DPM,TT570CL 10~100 10~100
999Pa
7.0kPa

TSI,8704 Extendable Pitot Tube


1.27~78.5 -1245~3735Pa
Differential Micro-
TSI,8705 Pitot Tube
manometer
Logging
RS232C Static Tip
TSI,8710 10~100 3735Pa Pitot Tube
Velocity Matrix
TSI,8345 0.15~30
93
TSI,8355 Anemometer (hot wire) 0.15~50

TSI,8384 0.1~50 60
Logging
TSI,8324 80 Max, Min & Articulated telescopic extension
Sweep
Anemometer
AIR,AV2 0.25~30 NATA version available
(vane, 100 mm)
70 Analog output
AIR,AV6 Logging
RS232C
Anemometer
SCH,MINI-2 0.3~40
(vane, 22 mm)
Results
TES,450 Anemometer 0.4~40 130 averaging Telescopic probe
(vane, 16mm) Min/Max display
Logging
TES,445 0.4~60 140 Micro-vane probe
Ma, Min & Mean
AIR,UA6 0~50 Low flow turbulence
Logging
Anemometer (ultrasonic) 70 Low flow turbulence
AIR,UA30 0~30 RS232C
Reads to 0.001 m/s
HOB,PRES Pressure logger 75 500~110,000Pa
Logging Flow – computer
KUR,2443-24 Air Velocity Meter 0~60 200 10*/20bar
With pipe-fittings*

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 113
AIR CONDITIONING & AIR QUALITY - HVAC & IAQ
Air Flow Measurement/Air Quality

Model Temp CO CO2 NO


Type RH% Dust & Aerosol Notes
O
C ppm ppm ppm
0.001~100mg/m3 Logging
TSI,8520
Particle measurement 0.1~10µ TSI,8520-1 Outdoor enclosure
ABA,301 0.3~5µ
Ultra fine particle 0.01 ~ 5x105 particles/cm3 Logging
TSI,8525
measurement 0.02~1µ
Multifunction air quality Logging, Wet bulb
TSI,8386A 60 5~95
meter Dew point, Differential pressure
TSI,8551 Indoor air quality monitor Logging
50 5~95 500 5,000
TSI,8554 (multi-function) RS232C/Software
Multifunction air quality
YES,205-5 50 5~95 200 10,000 300 Logging
logger
TES,645-1
Humidity & dewpoint meter 120 2~98 Robust stainless probe
TES,645-2
WBGT index, RH + Dewpoint
CAS,MICROTHERM Area heat stress monitor * * *Air temp to 60º, Wet temp to 40º
Globe temp to 120º

Portable Smoke Generating Machine


CSS,COLT4
Portable smoke generator with variable smoke emission rate. Suitable for
AU > NEW
TSI 8710 DP-CALC Differential Micro-Manometer
TSI,8710 AU
air flow visualisation, HVAC ductwork leak-testing, fire training and general Micro-manometer for static or differential pressure, velocity, volumetric
work. Pump-free operation with smoke fluid supplied from consumable flow, atmospheric pressure and temperature. With statistical analysis,
aerosol cans or refillable containers [pump supplied for pressurisation]. density correction, K factor and automatic actual/standard flow calculation.
Manual or continuous operation and off-power facility. Maximum output 31 Differential pressure range ±3735Pa. Velocity display to 78m/s (range
cubic meters/min at 1.5m visibility. Operation for 18min from one can at depends on probe). Supplied with static tip, Pitot tube, velocity matrix and
maximum capacity. temperature probe. Datalogging (1,000 point) with RS232C interface and
software. Rechargeable cells or AC adaptor.

> NEW
TSI 8705 DP-CALC Differential Micro-Manometer
TSI,8705 AU
Differential micro-manometer measuring differential pressure, velocity,
Airflow EDM2500 Electronic Manometer 0~2500 Pa average, volumetric flow, maximum and minimum. With static pressure
AIR,EDM2500 AU/NZ calculations, density correction and K factor. Pressure range -1245~3735Pa.
Pressure ranges 125, 500 & 2,500Pa. Air velocity measurement using pitot- Velocity range 1.27~78.5m/s. Supplied with 200~980mm telescopic pitot
static tube with ranges 14 & 28m/s. Supplied complete with pitot static tube, tube. Datalogging (1000 point) with RS232C interface and software. Battery
balancing valve, and tubing. Fitted with 1mA fsd recorder output. Battery powered.
operated.
Airflow DM2 Medium Pressure Manometer
AIR,DM2 NZ
Handheld medium pressure digital manometer. Suitable for positive,
negative and differential pressure measuements. Displays readings in mBar,
kPa & psi. Ranges are ±2,000mBar, 200kPa & 29.99psi. Resolution is 1 or
0.1mBar & 0.1 or 0.01kPa. Accuracy on all ranges is 0.5% of reading. Serial
interface for uploading stored results. Maximum stored readings during
logging is 700. Analogue output of ±1V at 0.5mV per mBar.

114
AIR CONDITIONING & AIR QUALITY - HVAC & IAQ
Air Flow Measurement/Air Quality
TSI 8704 DPCALC Micro Manometer TSI 8371 Accubalance Balometer
TSI,8704 AU TSI,8371 NZ
Measures differential pressure, velocity, average, volumetric flow, max & min. Airflow hood 610 x 610mm. Measures air volume flowing through registers,
With static pressure calculations, density correction and K factor. Pressure diffusers, and grilles. Range is 15~1,000l/s, accuracy is ±5%. Temperature
range -1245~3735Pa. Velocity range 1.25~78.5m/s. Extendable pitot tube range is 0~60ºC. Sample and hold function displays reading of one sample.
20~980mm. Datalogging 500 point with RS232C interface and software. Automatic conversion between actual and standard flows when user initially
inputs temperature and barometric pressure, variable time constant modes
DPM TT370S Digital Manometer available for a steady display when measuring fluctuating flows, K factor
DPM,TT370S NZ
function enables flexibility for measuring a variety of diffusers, back-lit display
Digital micromanometer with an extendable pitot tube kit. DP ranges are
is easy to read in poor lighting conditions.
199.9Pa, 1,999Pa & 7kPa. Velocity range with pitot kit is 1.2~100m/s. DP
accuracy is 1% of reading +2 counts. Recorder output of 1mV per count. TSI 8373 Balometer With Logging
TSI,8373 AU
DPM TT570CL Digital Manometer NATA Certification Flow range 15~1,000L/s (50~3,500m3/hr); accuracy ±5% [to ±2.4L/s].
DPM,TT570CL-NATA NZ
Operating temperature range 0~60OC. Includes 5 hood kit & hard case.
Digital micromanometer with an extendable pitot tube kit. DP ranges are
Hoods provided 610 x 610mm (standard), 610 x 1,220mm, 305 x 1,220mm,
199.9Pa, 1,999Pa & 7kPa. Velocity range with pitot kit is 1.2~100m/s.
305 x 1,525mm & 915 x 915mm.
DP accuracy is 1% of reading +2 counts. Built-in data logger holds 1,400
readings. TSI 8375 Accubalance Modular Air Balancing
TSI,8375 (NZ)
Druck DP1705 Manometer 0~20 kPa Balometer with detachable micromanometer for air balancing applications.
DRU,DPI705 AU
610 x 610mm air capture hood for measurements in the range 42~4,250m3/
Handheld digital manometer range 0~20kPa, accuracy 0.2 %. Displays all
h with automatic compensation for barometric pressure and air temperature,
common engineering units.
450mm pitot probe (range 0.13~41m/s), 16-point velocity matrix probe
Shortridge ADM-860 Electronic Manometer (0.13~13m/s) and static pressure probes (differential pressure range
SHO,ADM-860 AU/MY ±3,735Pa with safe limit 37kPa, absolute pressure range 47~135kPa).
Electronic micro manometer for air balance and similar applications. Accuracy typically 2% for pressure, 3% for flow. Large, multi-line backlit
Measures differential pressure, air velocity and temperature. Differential LCD display for single or statistical readings with min, max and average of
pressure range 0.0025~1,500mm wg. Velocity range 7.5~3,000m/min up to 1,000 values of each measured parameter. Manual result storage or
(750m/min with velgrid). Memory 100 point with sum and average. automatic data logging up to 1,000 time/date stamped readings. RS232 port
Accessories include pitot tube and 16 point velgrid for face velocity work for data transfer to PC or serial printer, with cable and “LogDat” download
including exhaust hoods, clean room outlets, and large filters or coils. software. Rechargeable with approx 12h operation, or ac adaptor.
Airflow 36 Pitot Tube Shortridge CFM88-3 Electronic Balometer
AIR,PITOT-36 AU SHO,CFM88-3 AU
Pitot tube (36”) for use with manometers and micro manometers. Measures supply and exhaust flow in cfm and l/sec. Ranges 25~2500cfm
supply and 25~1500cfm exhaust. Compensated for air density and back
Kurz 2443 Air Velocity Meter pressure. Hood sizes 600 x 600mm, 600 x 1,200mm & 300 x 1,200mm.
KUR,2443-24 AU
Portable air velocity meter and flow-computer. Working velocity range Airflow AV2 100mmØ Anemometer with Volume display
0~12,000 sf/m (60m/s) at pressures to approx 10bar (probe rated to 20bar). AIR,AV2 AU/NZ
Temperature range -40~200OC with compensation. Selectable English Vane anemometer with 900mm (35”) telescopic probe extension. Velocity
or metric units for velocity or mass-flow. Thermal sensor probe 9.5mmØ measurement range 0.25~30m/s (50~6,000ft/min). Averaging mode
x 330mm long with sensor-shield. Compression fitting and nylon ferrules available. Volume display based on duct or other area. Head operating
for probe removal or position adjustment in tapped pipe. Suitable for use range -10~70OC (lower limit of -30CC for short periods). Output 0~1V.
in ducts or pipes, min pipe 50mmØ approx. Calibrated for air and suitable
for use with other non-hazardous gases. Recording of up to 1,500 data sets
with time and date. Two analog 4~20mA outputs, and RS232C serial port for
configuration upload and data download. Rechargeable NiMH batteries.

Airflow AV2 100mmØ Anemometer NATA Certification


AIR,AV2-NATA AU
Specification as above but with NATA certification.
Airflow AV6 100mmØ Anemometer with Volume
AIR,AV6 NZ
Vane anemometer 100mmØ with articulating extension handle. Measures
TSI 8370 Accubalance Balometer velocity, volume flow and temperature. Vane head operating range is -
TSI,8370 MY
10~70ºC, -30 possible for short periods. Accuracy is ±1% of reading +1
Balometer including 5-hood kit and hard case. Flow range 15~1,000 litres/
digit. Resolution is 0.01 m/sec. Velocity range is 0.25~30m/s. RS-232C
sec (50 to 3,500m3/hr) accuracy +/-5%, reading +/- 2.4 l/s (8.5m3/hr).
interface for data logging & real time data retrieval. Stores up to 99 readings
Operating temp range 0-60OC. Weight (610 x 610mm hood) 3.4 kg hood
of velocity & temperature. Analogue output of 0~1v.
provided 610 x610mm (standard), 610 x 1220mm, 305 x 1220mm, 305 x
1525mm and 915 x 915mm. Schilknecht Mini Air 2 Vane Anemometer
SCH,MINI-2 AU
Probe 22mmØ. Range 0.3~40m/s. Min, max & time averaging functions
with 0~1V analog output.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 115
AIR CONDITIONING & AIR QUALITY - HVAC & IAQ
Air Flow Measurement/Air Quality

> NEW
Testo 445 Vane Anemometer with 16mm vane
TES,445 AU
> NEW TSI 8324 VelociCalc 100mm Vane Anemometer with
Volume Display
TSI,8324 AU
Micro-vane probe. Simultaneous digital display of air velocity and Vane anemometer with 100mm head, supplied with handle and 900 mm
temperature, with continuous-update, max, min & mean functions. Volume- articulated telescopic extension. Velocity measurement range 0.25~30 m/
flow option with entry of duct dimensions .Telescope mounted metal probe, s ±1%; temperature measurement range 0~80ºC ±0.5 ºC. Volume display
vane 16mmØ. Operating range 0.4~60 m/sec, accuracy ±0.2m/s, ±1%mv range 0~4.36x106m3/h with input for circular or rectangular duct dimensions.
up to 40m/sec. Temperature range -30~140ºC for short-term measurements. Variable time-constant; sample statistics average, max and min; and “sweep”
Selectable site-locations, and 3,000 point internal memory for manual saving mode for extended continuous sampling. Internal memory for single point
or automatic data logging. Battery powered. measurements or time-based data logging, for up to 2849 samples and 1000
test IDs, with serial interface, cable and software for data download. Direct
data acquisition [polling] from PC terminal modes. Battery powered with
auto-power-off, and optional AC adaptor.

TSI 8386A VelociCalc Air Conditioning Efficiency Meter


Testo 450 Vane Anemometer with 16mm Vane TSI,8386A AU
TES,450 AU Portable efficiency measurement system for HVAC and related work, with
Anemometer with micro-vane probe. Digital display of air velocity and hot wire anemometer, static and differential pressure, temperature and
temperature. Telescope mounted metal probe, diameter 16mm. Operating humidity measurement with heat flow efficiency calculation. Velocity (hot
range 0.4~40m/s ±0.2 and to 60m/s ±unspec. Temperature range - wire) 0~50m/s, accuracy ±3.0%. Temperature -10~60OC, accuracy ±0.3.
30~140OC for short-term measurements. Battery powered. Wet bulb temperature 5~60OC. Relative humidity 0~95%RH, accuracy ±3%.
Dewpoint -15~49OC. Static/differential pressure -1,245~3,735Pa, accuracy
TSI 8345 Hot Wire Anemometer ±1%. Probe length 100cm, tip diameter 7mm, base diameter 10mm.
TSI,8345 AU Includes data logging and printing. Battery operated.
Thermal anemometer range 0.15~30m/s; accuracy ±3%; volumetric Airflow UA30 High Resolution Ultrasonic Anemometer 0~30m/s
flow display; averaging capability up to 255 readings. Probe operating AIR,UA30 AU/NZ
temperature range -17.8~93.3OC. Probe 98mm long x 6mmØ at tip. Digital Precision anemometer range 0~30m/s, accuracy better than 1% of reading,
display. RS232C printer interface. Battery or mains operation. resolution 0.001m/s, non-directional. Temperature range 0~70OC, accuracy
1OC, resolution 0.1OC. Flow turbulence range 0~99%. Capable of measuring
very low air velocities. Includes articulating telescopic rod 0.4~1.1m. Logs up
to 99 readings of velocity, temperature and turbulence, intervals 1s~99min.
RS232C interface. Operates for 20h on alkaline batteries.

TSI 8355 Hot Wire Anemometer


TSI,8355 MY
Range 0.15~50m/s. Probe will operate over a temp range of -17.8~93.3ºC.
Digital display with averaging capability o up to 255 reading. Temperature
measurement range -17.8~+93.3 C RS 232 printer interface. Battery & AC
operation.
TSI 8384 Hot Wire Anemometer Airflow Ultrasonic Anemometer 0~50m/s
TSI,8384 NZ AIR,UA6 AU
Handheld hot wire anemometer. Velocity range is 0.1~50m/sec, accuracy Range 0~50m/s, accuracy better than 1% of reading, resolution 0.01m/s,
is ±3% of reading or ±0.015m/s whichever is greater. Resolution is 0.01 non-directional. Temperature range 0~70OC, accuracy 1OC, resolution
m/s. Probe temperature range is -10~60ºC and 0~80%RH. Stores 1,394 0.1OC. Flow turbulence range 0~99%. Capable of measuring very low air
samples of velocity, volumetric flow-rate and temperature with time and date velocities. Includes articulating telescopic rod 0.4~1.1m. Logs up to 99
stamping. Data can uploaded to a PC or printed. Supplied with 10mmØ x readings of velocity, temperature & turbulence, intervals 5s~99min. RS232C
1m telescopic probe. interface. Operates for 20h on alkaline batteries.

116
AIR CONDITIONING & AIR QUALITY - HVAC & IAQ
Air Flow Measurement/Air Quality

> NEW
Testo 635-2 Humidity, Temperature & Dewpoint Meter
TES,635-2 AU
TSI Q-Trak plus Indoor Air Quality Monitor with Logging
TSI,8554 AU/NZ
Indoor air quality (IAQ) monitor for temperature and humidity measurements,
Portable humidity meter fitted with robust stainless probe with sintered filter- CO and CO2 concentrations. Humidity range 0~95%, temperature range
cap for general or duct measurements to 120ºC, and fast-action K-type 0~50OC. Electrochemical cell for CO 0~500ppm. NDIR cell for CO2
surface temperature probe. Displays relative humidity, absolute humidity, 0~5000ppm. Data logging for 48,671 data points with interval adjustable
dew point, degree of humidity, enthalpy, temperature, and differential 1s~1h. Fitted with RS232 interface, and software included for download,
temperature (dewpoint~surface). Operating range 2~98%RH (±2%). Air storage and reporting. Battery or mains operation with ac adaptor.
temperature -20~120ºC (±0.2/0.5). Surface temperature -60~300ºC (±0.1).
Internal memory for 10,000 values with USB interface, cable and software
for download and presentation. Battery operated.

YES 205-5 Indoor Air Quality Monitor with Logging


YES,205-5 AU
5 channels for temperature, humidity, CO2, CO & NO. Temperature range
0~50OC, resolution 0.1, accuracy ±0.5. Humidity 5~95 %RH, accuracy
±2%. CO2 0~10,000 ppm, resolution 0.5ppm. CO 0~200 ppm, resolution
0.5ppm. NO 0~300 ppm, resolution 0.5ppm. Logging of CO and NO allows
checking of indoor air for contamination by vehicle emissions from nearby
carparks, loading docks etc. Includes interface and software. Mains/battery
Testo 635 Humidity & Dewpoint Meter operation.
TES,635 NZ/MY Casella Microtherm WBGT Area Heat Stress Monitor
Temperature, humidity and dew point meter. Probe temperature range is CAS,MICROTHERM AU
-20~70ºC. Humidity range is 0~100%RH resolution: 0.1%, accuracy is ±2%. Portable area heat stress WBGT monitor with real-time graphical display.
Dew point range is -50~40ºC. Measures heat stress potential [WBGT index] according to ISO7243. PRTD
Testo 645 Humidity & Dewpoint Meter sensors with internal calibration-reference for wet-bulb, dry-bulb and globe
TES,645-1 AU temperatures. Large LCD display for numerical or graphical indication of
Portable humidity meter fitted with robust stainless probe for ambient work or temperatures and processed values for WBGT [indoor/outdoor plus TWA],
duct measurements to 120OC. Displays relative humidity, absolute humidity, relative humidity and dewpoint. Simple keypad/menu setup. Data logging
dew point, degree of humidity, enthalpy and temperature. Operating range for up to 32 separate runs and 49,100 records, with interval 30s~1h. RS232C
2~98%RH [±2%], -20~120OC [±0.4/0.5]. Battery operated. port with included PC software for download and reporting or realtime
display. Low water-level warning, and settable audible/visible WBGT alarm.
Abacus Hand-held Airborne Particle Counter Handheld, free-standing or tripod-mount. Battery operated.
ABA,301 AU
Portable particle measuring system typically used in clean room applications. TSI 8520 DustTrak Airborne Particle Monitor
4 x fixed size channels 0.3, 0.5, 1.0 & 5.0micron. Count data automatically TSI,8520 AU/NZ
stored in a 500 sample memory which can be downloaded to a PC. Portable aerosol monitor. Laser photometer with 90O scattering detection,
Selectable sample time. Includes zero count filter for checking backgrounds. Range: 0.001~100mg/m3 [Calibrated for A1 test dust, ISO 121203-1],
When used with included software will check clean rooms to ISO 14644 and resolution: 1% of reading or 0.001; particle size range: 0.1~10µm. Internal
BS5295 requirements. Battery operated. pump flow rate 1.4~2.4L/min (1.7 nominal). Data logging 30,000 data points
(21d @ 1min), log interval: 1s~1h. RS232C interface and software included.
Vaisala WAA151 Wind Speed/Direction Transducer Battery operated.
VAI,WAA151 AU
Range 0.4~75m/s. Current output with selectable ranges including 4~20mA TSI 8520-1 Environmental Enclosure for DustTrak
& 0~20mA. Requires indicator module such as DE,DT600 datalogger for TSI,8520-1 AU
indication of windspeed and direction. Weatherproof outdoor housing for TSI,8520 aerosol monitor. Rugged case
with tripod mount, fitted with sample inlet and water trap. Includes extended-
TSI 8551 Indoor Air Quality Monitor with Logging life battery pack and charger/adaptor.
TSI,8551 AU
Measures temperature, humidity, CO & CO2 concentrations. Humidity TSI 8525 P-Trak Ultrafine Particle Counter
5~95%RH, CO 0~500ppm, CO2 0~5,000 ppm. Internal logging up to 63,000 TSI,8525 AU
data points; interval adjustable 1s~1h; RS232C interface and software Range 0.01~5 x 105 particles/cm3. Particle size range 0.02 to greater than
included. Battery or mains operation. 1micron. Includes PC software and cable. Suitable for detection of ultrafine
particles associated with pollutants. Battery powered [8h operation using
alkaline batteries].

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 117
AIR CONDITIONING & AIR QUALITY - HVAC & IAQ
Air Conditioning Balancing Instruments
> NEW
Testo 560-2 Electronic Manifold for Refrigeration Testing
TES,560-2 AU
Tour & Anderson CBI Balancing Meter
TA,CBI
Digital pressure balancing instrument with LCD display. For cooling water
AU

Three-way valve bank, for commissioning, maintenance and repair valve balancing in air conditioning plants and similar applications. Firmware
of refrigeration systems. Stainless-steel block for use with common revision 3A. Includes facility for entry of Kv value to allow balancing of all
pressure media including CFC, FC, N, CO2 and ammonia; with stored hydronic valve types. Differential pressure range -0.5~20.5m water gauge
data (including saturation properties) on 36 refrigerants. Measurement of at a total pressure of less than 200m. Resolution 0.001m. Flow resolution
vacuum (0~200hPa), pressure (0-50bar), ambient [case] temperature for 0.001L/s. Battery operated.
compensation (-10~50ºC) and system temperature (-100~400ºC instrument
range; supplied with pipe-wrap probe 0~120ºC). Calculations for absolute/
relative pressure, vacuum drying-efficiency, system cooling/heating capacity,
leakage testing, superheating or sub-cooling values. Data storage, or
interval-logging up to 100,000 readings, with serial interface and software
for download, analysis and documentation. Battery or AC adaptor powered.

Leakage Detectors
Haloteck Refrigerant Gas Leak Detector GasCheck 3000 Portable General-purpose Leak Detector
HAL,78000 AU ION,GASCHECK3000 AU
For use by refrigeration engineers. Rapid response 0.2s, audio output, Micro thermal-conductivity sensor for high-sensitivity detection of gases
zero warm up time. Single control, battery operated, sensor tip insensitive with a thermal conductivity different to that of air, including helium, carbon
to draughts. Sensitivity better than 3g/y R12, 25g/y R134A. Responds to dioxide, refrigerants, sulphur hexafluoride, natural gas, etc in 5 groups.
halogenated hydrocarbons and many fire extinguishant gases, [also sulphur Direct reading of leak rate in ml/sec with audio and visible signals. Detection
hexafluoride SF6]. Battery life 30h. Duty cycle continuous. Probe length limit for helium 2E-5ml/s. Battery powered.
240mm. Weight 280g.
Bacarach Leakator 10 Combustible Gas Leak Detector
BAC,LEAK10 AU
Flexible probe with solid-state sensor for rapid area checks and pinpointing
of large or small leaks. Sensitive to combustible vapours including common
solvents, and gases including natural gas. Adjustable sensitivity with
detection limit approximately 20ppm [methane]. Indication by ultra-bright
LEDs and audible speaker. Battery powered.

Weather Stations

> NEW
Environdata WeatherOne Wind Speed & Direction Logger
ENV,DL20WSD AU
Environdata WeatherMaster 2000 Weather Station
ENV,WM20
Measures air temperature -15~50OC ±0.2, relative humidity 10~90%RH
AU

Logging system for wind speed and direction. Tripod-mounted cross-arm ±5%, rainfall 0.2mm resolution. Wind speed starting threshold 1kph. Wind
stand with 3-cup windspeed sensor range 0-75m/s and independent vane direction resolution 6O ±3%. One spare input channel. Capable of storing
direction sensor. Sealed dual-channel logger with memory for 35,000 up to 3mths of data. Includes RS232 interface and software for download.
readings with time and date, fitted with backup battery, rechargeable sealed Mounts on star-picket. Solar-rechargeable batteries.
main battery and solar panel for in-field recharge. Power supply for charging
or operation from mains supply. “EasiAccess” software on CD for office or
field connection via RS232C compatible computer (not included), for set-
up, download and real-time operation, with functions for tabular or graphical
display.

118
OCCUPATIONAL HEALTH & SAFETY
Light & UV Measurement
Hioki Lux HiTester Digital Illuminance Meter Minolta CL-200 Chroma Meter for illuminance & Colour
HIO,3423 AU/MY/NZ Measurement
HIO,3423-NATA NZ MIN,CL200 AU
Manual switching and autoranging. LCD display with 3½ digits (“1999”) for Konica Minolta model CL-200 portable colour meter. LCD display for
five measuring ranges to 20/200/2000lx in 1-count steps, 20,000lx in 10- illuminance, tristimulus values, chromaticity, correlated colour temperature
count steps and 200,000lx in 100-count steps with accuracy ±4%. Response and colour difference. Illuminance range 0.1~99,990lx ±2%. Colour accuracy
time in autorange mode 5sec (2sec in manual range mode). Autozero, hold ±0.002 [xy] or ±20°K [Tcp]. Fitted with RS232C interface. Battery powered,
and backlight function with delay for taking readings in low light. Input for or AC adapter.
ac power adaptor, connecting-cable to allow separation of sensor unit and
meter, and 200mVdc analog output with cable. Battery powered.

Topcon BM-9 Luminance Meter


TOP,BM-9-2 AU
Portable luminance meter with digital display. Field-of-view 5O, measurement
acceptance angle 2O, with 10mm min spot diameter. Measuring distance
Extech Digital Light Meter Nata 0.35m to infinity. Silicon photodiode sensor with automatic or manual range
EXT,407026 NZ selection. Measurement range 0.01~199,900cd/m2 ±4% of reading. Built-in
NATA calibrated portable digital light meter. Ranges; 2,000, 20,000 & 50,000 RS232C interface and analogue output. Battery powered.
lux. Accuracy is ±4%. Displays in foot candles or lux for tungsten, daylight, Topcon IM-2D Digital Luxmeter
fluorescent, sodium or mercury lamps. Data logging of measured values, TOP,IM-2D AU
Min/Max & Average, software and serial interface for uploading results. Digital illuminance meter. Measuring range from 0.1~19,999lx. Accuracy
Minolta T-1 Lux Meter ±5%, +1 digit. Autoranging with silicon sensor. Battery operated.
MIN,T-1 NZ
Topcon IM-2D Lux Meter NATA Certification
Microprocessor controlled digital light meter. Measuring time can be TOP,IM-2D-NATA AU
adjusted for accurate readings of both continuous and flickering light Digital illuminance meter with NATA certification. Measuring range from
sources. Illuminance deviation between sources can also be determined, 0.1~19,999lx. Accuracy 5%, ±1 digit. Autoranging with silicon sensor.
or integrated illuminance over a period of time can be calculated. Range is Battery operated.
0.01~99,900lx. Accuracy is ±2%.
ILI 1400ABC Radiometer for UV Measurements
ILI,1400ABC AU
International Light model 1400 radiometer with backlit LCD display, autozero
and autoranging. Continuous reading with hold function, or integrated “dose”
measurement up to 24h. Smart detectors with storage of units and detector-
calibration data. Analogue recorder output. Mains adaptor or battery power.
Supplied with three sensors: UV actinic hazard (UVC with B & A components
matched to OSHA requirements), range 2.50e-7 to 2.50e-3 W/cm2 eff. UVB
+ A (total “solar” radiation), range 1.16e-7 to 4.07e-1 W/cm2. UVB, range
1.54e-6 to 1.54e-2 W/cm2.

Topcon IM-5 Lux Meter NATA Certification


TOP,IM-5-NATA AU
Digital wide-range illuminance meter with NATA certification. Measuring
range 0.01~199,000lx. Accuracy ±2% +1 digit. Autoranging with silicon
sensor. Analog output and RS232 interface. Battery operated.

Sound Signal Analysis


HP35660A 100kHz Dual Channel Spectrum Analyser
HP,35660A AU
401 line resolution. Displays frequency response, power spectrum, linear spectrum, coherence, cross spectrum, power spectral density, and time. Signal
sources: fixed sine, random noise, chirp. Built-in disk drive. HPIB plotter interface. Bandwidth is 102.4kHz for single channel measurements and 51.2kHz
for dual channel measurements.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 119
OCCUPATIONAL HEALTH & SAFETY
Noise & Sound Analysers
Model Description Type/Class Features RS232C Major Applications
BK,4443 Noise dosemeter (2) Built-in set up routines, 53,000 values OH&S

BK,2237A 40 data records, ac output


BK,2237A-NATA NATA certificate, ac output Yes OH&S
RIO,NL-04 2 ac & dc outputs General

RIO,NL05 Recorder outputs


QUE,2400 ac & dc outputs General
BK,2239A-NATA NATA certificate, ac output Yes
OH&S
RIO,NL-11FP Octave filter,printer
Sound level meter General
RIO,NL14 1/1 octave filter, ac & dc outputs Yes
RIO,NL14-NATA 1/1, 1/3 octave filter, NATA certificate
RIO,NL31 1 1/1, 1/3 octave filter
NATA certificate, Data logging OH&S
RIO,NL-32RTA-NATA Realtime frequency analysis General
(1/1, 1/3 octave), “Flashcard” Analysis
Enhanced sound level meter firmware
BK,2238E-NATA Data logging, Frequency analysis Yes
NATA certificate
BK,7815 Software n/a Compatible with BK4443, 2239A, 2238E-NATA n/a Advanced applications

ARL,EL-215 2,048 data sets, Weatherproof


2 7,500 data sets, Display
ARL,EL-315
Weatherproof
Environmental noise
7,500 data sets, Display Yes Long term outdoor logging
ARL,EL-316 logger
Weatherproof
1
25MB memory, Weatherproof
BK,2238NMT-KIT
With sound level meter
Audio Analysis Includes PDA, real time analysis, FFT, signal General Analysis
IVI,IE35-2P 1
System generation, reverb, “seat-to-seat”, PC download Engineering, Audiovisual

> NEW
ARL EL-316 Environmental Noise Logger Type 1
ARL,EL-316 AU
> NEW
Ivie IE-35 Type 1 Audio Analysis Systems
IVI,IE35-2P AU
Environmental noise logger with display for field-reading of summary results. Audio Analyser with Dell Axim X51v PDA. Fitted with half-inch free-field
Portable, self-contained and weatherproof. Type 1 performance, continuous Type 1 microphone and pre-amplifier. Functions include SPL (sound level),
90dB dynamic range, fast response, frequency weightings A and C. Monitors Real-time analysis, “seat-to-seat” variation for audio setup, reverberation
environmental noise continuously for up to 3 weeks, calculates and stores measurement, “strip-chart” recording on display, voltage and oscilloscope
over 7500 sets of Ln indices. PC required to set up system and download displays and signal generation. Supplied with field-calibrator, microphone
data using software supplied. Set up also possible from front-panel. extension cable, spare battery and software for data-download to PC. SPL
facilities include time and frequency weightings - fast, slow, peak or impulse
and A, C or Flat. FFT based Real Time Analysis includes 1/1, 1/3, or 1/6
octave bands with a maximum resolution of about 1/24 octave. Additional
functions include spectrum subtraction, averaging, Noise Critera or Reduction
contours and reverberation-decay to ISO-20 and ISO-30. Signal-generation
includes sine, square, triangle and white or pink noise.

120
OCCUPATIONAL HEALTH & SAFETY
Noise & Sound Analysers
B&K Noise Monitoring Terminal with model 2238F SLM B&K 2239A Type 1 Sound Level Meter NATA Certification
BK,2238NMT-KIT au BK,2239A-NATA AU
Noise logging system with B&K model 2238F Class 1 Sound Level Meter Type 1 (class 1) integrating sound level meter with backlit LCD display, NATA
equipped with internal software for Basic SLM and Logging. Portable, certification. Simultaneous rms (A,C) & peak (C) detection with independent
wheeled weatherproof case. Standard SLM operation for fast, slow and frequency weightings. Measuring range 30~140dB. Time weightings fast,
impulse time weighings and A, C or linear frequency weightings RMS. Linear slow and impulse. Parameters Leq, MaxP, MaxL, MinL, Peak, SPL and
or C frequency weightings for peak detection. Internal memory 2MB total Inst. Memory for 40 data records with realtime clock. Serial port for data
for logging up to 12 parameters including auxiliary signals. Fitted with serial download. Calibrator included. Operates with 4 x AA alkaline batteries.
RS232 interface, and provided with BKlink software for download of logged
data to PC. Supplied with field calibrator, charger and 12V, 18Ah battery, for
Rion NL14 Type 1 Sound Level Meter/Analyser
RIO,NL14 AU/MY
operation for up to 14d logging at 15min intervals.
Precision integrating sound level meter meeting IEC type 1 standard. Fitted
with NX-04 single octave filter module range 31.5~16kHz in 10 bands.
Supplied with NC73 calibrator. Weightings A, C, & flat. Measurement range
with A weighting 25~130dBA. Measurement functions Lp (SPL), Lmax, Leq,
Lae, Lx. Time weightings fast, slow, impulse, 10ms, peak hold. Leq time
from 10s~100h. In-built memory for up to 9,000 readings (LP). Outputs 1V
ac rms, 3.5V dc, RS232C interface. Continuous operation on batteries for
12h. AC adaptor included.
Rion NL14 SLM with 1/3 & 1/1 Octave Filter NATA Certification
RIO,NL14-NATA AU
Precision integrating sound level meter to IEC type 1 (class 1) specification,
with NATA certification. Supplied with 1/1 & 1/3 octave filter module NX-05,
B&K 4443 Noise Dose Meter with Logging and calibrator NC73. Frequency range 20~12,500Hz with weightings A, C, &
BK,4443 AU/NZ
flat. Measurement range (A) 25~130dB. Measurement functions Lp (SPL),
Fitted with remote microphone, for OH&S surveys. Logging of 1 or 2
Lmax, Leq, Lae, Lx. Time weightings fast, slow, impulse, 10ms, peak hold.
parameters from a range of 6, with variable interval. 4 built-in and 3 user-
Leq time from 10s~100h. In-built memory for up to 9,000 readings (Lp).
defined setup routines, 5 selectable statistical levels Lx. Storage of up to
Outputs 1V ac rms, 3.5V dc fs, RS232C interface. Alkaline batteries 12h
53,000 values over 16 measurement periods, and download [or setup] via
operation or ac adaptor.
PC using software provided. Supplied complete with field calibrator. Battery
powered. Rion NL-31 Type 1 SLM with 1/1 & 1/3 Octave Filter
RIO,NL31 NZ
B&K 2237A Type 2 Integrating Sound Level Meter Complies with standards, IEC60651: 1979 Type 1, IEC60804: 1985 Type 1,
BK,2237A AU
IEC/CDV: 61672-1 Class 1. Simultaneous measurement of: sound level (Lp),
Measures RMS and peak simultaneously. Linearly weighted analogue output
equivalent continuous sound presure level (Leq), sound exposure level (LE),
for sound recording, 0~0.5V ac (rms). Measurement range 30~140dB.
Maximum (Lmax) & Minimum (Lmin), percentile sound pressure level (LN),
Time weightings fast, slow & impulse. Independent frequency weightings
5 selectable settings. Measurement ranges are: A weighting: 28~138dB,
A [for RMS readings SPL, MaxL, MinL, Leq, Inst] and C [for peak readings
C weighting: 33~138dB, flat: 38~138dB, peak sound level: 141dB. Time
Peak and MaxP]. Real time clock for time and date stamp. Records 40
weightings are: fast, slow, impulse (impulse is selectable only for auxiliary
measurements for download to PC. Calibrator included. Battery operated.
processing functions). Ranges 100dB dynamic, frequency 20~12,500Hz
Quest 2400 Type 2 Sound Sound Level Meter (including microphone). Timer function for automatic measurement over
QUE,2400 NZ extended periods. Supplied with NX-21SA 1/1 and 1/3 octave filter card.
Type 2 sound level meter with LCD display for sound pressure level (SPL) or
maximum level (MAX). Frequency weightings A & C, time weightings Fast
Rion NL-32 SLM with RTA & NATA Certification
RIO,NL-32RTA-NATA AU
and Slow. Ranges 30~140dBA and 40~140dBC with overload indication. AC
RIO,NL-32 NZ
& dc outputs. Battery powered.
Precision integrating sound level meter to IEC type 1 (class 1) specification,
Rion NL-04 Sound Level Meter with NATA calibration. Fitted with internal Compact Flash Card reader
RIO,NL-04 MY and supplied with NC-74 field calibrator. Frequency range 20~20,000Hz
Meets IEC type 2. Five measurement functions: Lp(SPL), Leq, LAE, Lmax & with weightings A, C, and flat. Time weightings fast, slow and impulse.
Lx(L5,L10,L50,L90,L95). 6 automatic measurements & data store. Built-in Measurement range (A) 28~138 dB. Broadband measurement functions
RS232C interface for computer communication. 70dB dynamic range (digital Lp (SPL), Leq, Lmax/min, Lae, Lx, and selectable auxiliary functions with
display), 27~130dB (A) measuring range. Wide range of time settings for manual or auto storage [logging]. Measurement time (Leq) from 10 seconds
Leq, LAE, Lmax & Lx;10s,1,5,10, 15, 30min,1, 8, 24h & manual time setting to 200 hours. Inbuilt memory for up to 100 data sets, or to limit of fitted CF
(up to 99h 59min 59s). RMS: fast, slow,10ms. 4 digit LCD display, 0.1dB card using manual or auto storage. AC or dc outputs, RS232C interface and
resolution, updated every second, plus 60dB analog display display 1dB cable CC-93 for serial printer. Supplied with NX-22RT card for real time 1/1
resolution showing the instantaneous value. Memory battery back-up. AC & and 1/3 octave analysis and display, for measurement functions Lp, Leq,
DC signal o/p for level expanding system by optional filters, memory card & LE, Lmax and display of AP (all-pass) AP(A) and 1/1 or 1/3 octave values
others. as selected, with manual data storage only to NX-22RT card. Download of
card-data to PC requires flashcard reader. Alkaline batteries (24h operation)
Rion NL-05 Type 2 Sound Level Meter or AC adaptor.
RIO,NL-05 AU
Sound level meter to IEC 651/1979 & IEC 804/1985 type 2 requirements.
Measures Lp, Lmax, Leq, Lae. Response types A, C, and flat. Fast and
slow time weightings. Complete with calibrator. Internal memory and print-
out for Leq data (printer CP-10 optional, also prints other parameters),
RS232C interface. Recorder outputs 1V ac rms & 3.5V dc. Operates from
batteries or ac adaptor.
Rion NL-11FP Sound Level Meter System
RIO,NL-11FP MY
Sound level meter complete with type NX-01A octave filter, CP-01 printer, &
calibrator. Measures Leq, Le (Lax), Spl and time. Weighting filters A, C, and
flat. Detector reads fast, slow, impulse, and peak (IEC 651). Measurement
range 29 ~140 dB rms.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 121
OCCUPATIONAL HEALTH & SAFETY
Noise & Sound Analysers
B&K 2238E Type 1 Integrating SLM Enhanced Software & ARL EL-315 Environmental Noise Logger
Logging ARL,EL-315 AU/NZ/MY
BK,2238E-NATA AU Environmental noise logger with display for field-reading of summary results.
Type 1 (class 1) Integrating sound level meter with additional functions Portable, self-contained and weatherproof. Continuous 90dB dynamic range,
including enhanced software, frequency analysis and data logging. Standard frequency weightings A and C. Monitors environmental noise continuously
routines include functions for workplace measurements and general sound- for up to 3 weeks, calculates and stores over 7500 sets of Ln indices. PC
level checks; enhanced software (firmware) offers additional measurements required to set up system and download data using software supplied. Set
and statistics for assessment of environmental noise problems; frequency up also possible from front-panel.
analysis automates measurements in the 9 single octave bands and 29 1/3
octave bands. Supplied with field calibrator. Compatible with BK,7815 Noise
Explorer Environmental software for download, data analysis and display.
B&K 7815 Environmental Software - Noise Explorer
BK,7815 AU
Software package for downloading and reporting of noise data measured
with B&K meters. Compatible with sound level meters (2239, 2238) and
noise dosemeters (4443). Offers data transfer, formatting of data for export,
display and print in tabular or graphical form, file management and calculation
of sound power or sound reduction index from intensity measurements.
ARL EL-215 Environmental Noise Logger
ARL,EL-215 AU
Environmental noise logger. Portable, self-contained and weatherproof.
Monitors environmental noise continuously for up to 3 weeks. Calculates
and stores 2048 sets of measured data. Continuous 90dB dynamic range. A
and C frequency weightings. Logs date, time, Leq, Lmax, L1, L5, L10, L50,
L90, L95, L99, Lmin, temperature and battery (plus additional sensor). Scan
interval 1 min~1 hour. RS232C interface. PC required for initial setup and
results download.

OH&S & Environmental - General


TSI SidePak SP730 Personal Sampling Pump Severn Model Tortus II Floor Slip Tester
TSI,SP730 AU SEV,TORTUSII AU
Personal sampling pump with internal digital flowmeter. Flow range Floor friction tester. Measures and records the dynamic coefficient of
to 3,000ml/min with internal low-flow bypass for precise control and friction. Applications in assessing floor safety, evaluating cleaning methods
measurement at low and high rates. Keypad programming with lockout and maintenance procedures, accident investigation, etc. Meets the draft
option. Multimode operation for manual control and preset programs with requirements of international, Australian and New Zealand standards.
intermittent sampling. Supplied with “TrakPro” data analysis software and
USB interface. Battery powered, 2,700mAH rechargable NiMH gives up to
18.5h at 1L/min. Intrinsically safe.

Lion Breath Alcohol Analyser


LIO,SD-400P AU
Portable breath alcohol analyser with attached printer. Uses disposable
mouthpieces. Approved by most law-enforcement agencies.

122
GAS ANALYSIS
Gas Analysis & Monitoring
Efficiency Temp °C
Model O2 CO CO2 NO NO2 SO2 H2S CH4 Notes Type
Calculations Max
Industrial
TES,325-1 Y Y Y* Y Domestic & light 600 Combustion efficiency
Oil & gas burners
TES,300M Y Y Y* Y Y Domestic 1,200 Combustion efficiency
TES,325M Y Y Industrial 500
Flue Gas Analyser
TES,335 Y Y Y Y Y Y Industrial 1,000
Domestic Combustion
TES,350 Y Y Y* Y Y Y Y 1,200
Industrial Flue Gas analysis
Power generation
TES,350XL Y Y Y Y Y Y Y General 1,000 Combustion efficiency

Domestic, Industrial Combustion


LAN,SERIES2-6 Y Y Y* Y Y Y Y Y 1,000
Power generation Flue Gas analysis
O2 by Zirconia sensor
NOV,1637-5CGA Y Y ~600 Flue gas analysis
CO2 by NDIR
Flue gas and general
Dual range
ISC,MDU420 Y ~1,000 analysis
NDIR methane analyser
Methane
*Calculated

LEL C O
Model O2 H2S Other Notes Applications
(combustion) ppm
50 ppm (CH4) to Full confined space kit
ISC,ITX-STD Personal monitoring
100% LEL Logging & download
30% 1,000 1,000 Confined space entry
ISC,TMX412 Full confined space kit
ISC,MG140 100%
Personal monitoring
AIM,4650 25% 1,500 500 Logging
General purpose
from 1 Zirconia & NDIR sensors
NOV,1637-5 CO2~100 % Scientific
ppm Wide range
Food packaging
NDIR sensor General purpose
ISC,MDU420 CH4~100 %
Logging & download Landfill methane
O3 Mains or battery
AER,500L Portable Logging Ozone Monitor
0~0.500ppm Logging & download
Indoor air quality
Formaldehyde emissions “Sick Building” syndrome
Formaldehyde
PPM,FORM400 from resins, furniture, textiles,
0.05~10.00 ppm
etc
LIO,SD-400P Alcohol Approved design Breath – alcohol
Detects, screens and measures VOC contaminants. Sensitive to Environmental & OH&S
RAE,MR200 Photoionisation detector
Benzene, Ammonia, Gasoline vapour and many more. General
Environmental & OH&S
Portable leak detector for combustion gases. Detects methane Visual & audible leak
BAC,LEAK10 Heating, Ventilation & Aircon
to ~ 20 ppm indication
(“HVAC”)

Portable leak detector using thermal conductivity. General purpose


ION,GASCHECK3000 Visual & audible signal
Wide range of gases including helium. High sensitivity

Carbon Monoxide Car Parks


APT,ODA6000CP Portable Gas Monitor
Nitrogen Dioxide Loading Areas

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 123
GAS ANALYSIS
Gas Analysis & Monitoring

> NEW
Testo 335 Combustion Gas Analyser
TES,335 au
> NEW
Testo 325M Combustion Gas Analyser
TES,325M AU
Portable industrial flue gas analyser. Determines temperature (to ~1000 Portable flue gas analyser for tuning, maintenance and service adjustments
deg C), draught/pressure (±40hPa), oxygen (21%), carbon monoxide of oil and gas burners. Determines temperature (to ~500ºC), draught/
(10,000ppm) and nitric oxide NO (3000ppm) concentrations. Calculates pressure, oxygen (21%) and carbon monoxide (4000ppm) concentrations.
carbon dioxide concentration, efficiency and flue gas loss. Threshold- Calculates carbon dioxide concentration and gross/net efficiency. Supplied
protection of sensors, with 5X autodilution of CO to 50,000ppm. Separate as kit with probe, cordless printer and power supply for mains operation.
sensor-socket with mini-probe for ambient temperature, and connection Operation 230Vac (with power supply) or alkaline batteries (AA also required
points for compatible differential-pressure devices. Built-in condensate- by printer).
trap with warning and auto-switch-off. Internal memory [100 folders X 10
locations X 200 datasets each] for storage of measurement-protocols and
data for printout. Supplied as kit with 335mm probe, cone and shield-plate,
cordless printer and power supply. Rechargeable or AC operation (alkaline
batteries used by printer).

124
GAS ANALYSIS
Gas Analysis & Monitoring
Testo 325-1 Combustion Gas Analyser Testo 350XL Portable Flue Gas Analyser
TES,325-1 AU TES,350XL AU
Portable flue gas analyser for measurements and adjustments of oil and Portable flue gas analyser. Measures O2, CO, CO2 (measured by NDIR),
gas burners. Determines temperature (to 600OC), draught/pressure, oxygen NO, NO2, and SO2 concentrations plus draught, temperature, excess air,
(21%) and carbon monoxide (2,000ppm) concentrations. Calculates CO2 and gross/net efficiency values. Ranges: O2 0~25% vol, CO2 0~50% vol, CO
concentration and gross/net efficiency. Supplied as kit with probe, cordless with H2compensation 0~10,000 ppm with measuring-range extension and
printer and power supply for mains operation. Operation 230V ac (with selectable dilution factor, NO 0~3,000 ppm, NO2 0~500 ppm, SO2 0~5,000
power supply) or alkaline batteries (AA, also required by printer). ppm, draught 50 hPa, temperature -40~+1,000OC. Includes switch-off and
rinse function for CO cell and fresh air rinse for longer term measurements.
Testo 300M Combustion Gas Analyser Internal memory for 250,000 readings, with RS232C interface and software
TES,300M AU/NZ/MY
provided. Operation from mains or rechargeable battery.
Flue gas analyser for combustion efficiency measurement. Temperature
range -40~1200OC ±0.5 (<100) ±0.5% (>100) with gas probe operation to
1,000OC max. Draught/pressure range 80mBar, ±0.03 . Gases measured: O2
0~21%, ±0.2%; CO2 [calculated] 0~CO2 max %vol ±0.2%; CO 0~8,000ppm,
±20 (<400), 5% (<2,000) & 10%; NO 0~3,000ppm ±5 (<100), 5% (<2,000) &
10%. Calculated gross/net efficiency 0~120%, 0.1% resolution.
TSI CaCalc CA-6215 Combustion Analyser
TSI,CA6215 NZ
Portable combustion analyser for tuning burners for max efficiency.
Measures O2, CO, NO & NOx, flue gas temperature & draft pressure.
Calculates efficiency, excess air, %CO2 and emission rates. Emission gas
concentrations use the adjustable O2 reference. Stores up to 350 samples
for 35 sites and 75 systems and stored data includes fuel parameters, time
and date stamping. Has RS232 interface for uploading of stored data or unit
can be supplied with optional printer for instant hard copy output.
Lancom Series II Combustion Gas Analyser Testo 350 Combustion Gas Analyser
LAN,SERIES2-6 AU TES,350 AU
Lightweight portable flue gas analyser with data logging. Measures O 25%, Measures O2, CO, CO2, NO, NO2, and SO2 concentrations. Calculates CO2
CO 2,000/4,0000ppm, SO2 2,000ppm, NO 1,000ppm, NO2 100ppm & H2S concentration and indicates draught, temperature, excess air, and gross/
200ppm. Calculates CO2 efficiency, excess air and loss. Probe temperature net efficiency values. Ranges: O2 0~21% vol, CO with H2 compensation
600OC continuous, 1,000OC intermittent. Fitted with sleep & wake facility 0~10,000ppm, NO 0~3,000ppm, NO2 0~500ppm, SO2 0~5,000ppm, draught
for semi continuous monitoring. With serial port and software. Internal ( 50hPa), temperature -40~1,200OC. Complete with printer and RS232C
rechargable battery and mains power supply. interface. Battery and ac mains operation.
AIM 650 Four-Gas Monitor with Internal Logging Novatech O2 & CO2 Combustion Gas Analyser
AIM,4650 AU NOV,1637-5CGA AU
Four gas toxic/combustible confined space or personal monitor with data Oxygen and carbon dioxide analyser for flue gas/combustion gas
logging and internal recall. Measures combustibles (CH4 equivalent) 0~100% applications. Special version of model 1637-5, with steel transfer tubing,
LEL, O 0~100%, CO 0~1,500ppm & H2S 0~500ppm. Alkaline batteries for closed IR cell (sapphire windows) and ruggedised internal flow path. Fitted
12~18h operation. with filtration system for moisture protection. 240V, 50Hz.
Bacarach Leakator 10 Combustible Gas Leak Detector Portable Logging Ozone Monitor
BAC,LEAK10 AU AER,500L AU
Portable leak detector for combustible gases. Flexible probe with solid-state Portable ozone monitor fitted with low concentration-range detection
sensor for rapid area checks and pinpointing of large or small leaks. Sensitive head. Operating range 0.000 to 0.500 ppm ozone with display in ppm or
to combustible vapours including common solvents, and gases including mg/m3. Gas sensitive semiconductor [GSS] sensor for accurate low-level
natural gas. Adjustable sensitivity with detection limit approximately 20ppm measurements, T90 response approximately 100 sec. Operation from mains
[methane]. Indication by ultra-bright LEDs and audible speaker. Battery power supply or battery pack (4 hours operation). Internal data logging for
powered. 8000 points with software and cable for download to PC, or data logging
direct to PC. Application for indoor air quality measurements.
PPM 400 Portable Formaldehyde Meter
PPM,FORM400 AU
Portable Formaldehyde meter for measuring airborne formaldehyde in the
workplace. Electrochemical sensor, with internal pump for rapid response.
Operating range 0.05~10ppm with readout on 4 digit LCD display. Kit
includes field calibration standard. Operates from 9V alkaline battery.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 125
GAS ANALYSIS
Gas Analysis & Monitoring
ISC MG140 4-gas Personal Monitor for CH44 , O2, CO & H2S ISC ITX 4-Gas Monitor Confined Space & Logging
ISC,MG140 AU ISC,ITX-STD AU
Four gas personal monitor for combustible gases (% LEL), oxygen (% O2), Multi-gas monitor with confined-space kit and logging option. Configured
carbon monoxide (ppm CO) and hydrogen sulphide (ppm H2S). International for 4 gases: combustible 50ppm~100%LEL, oxygen 0~30%, CO 0~999ppm
approvals UL & CSA - class 1, groups A, B, C & D. Audible [90dB] and visual & H2S 0~999ppm. Intrinsically safe: Ex ia d I/IIC T4[Australia]. Confined
alarms. Supplied with case and belt-loop, calibration cup and battery charger. space kit includes motorised pump, tubing, calibration cup and regulator.
Run time 8-10h on full charge. Logging option by time or event, up to 300h survey data at 1min intervals,
with datalink/software for download. Includes training video, Li-ion battery
pack with charger, and backup alkaline-battery pack.

ISC Gas Monitor for CH4, O2, CO & H2S


ISC,TMX412 AU/NZ
Four gas monitor complete with confined space entry kit. Detects 4 gases
flammable (CH4), oxygen (O2), carbon monoxide (CO) and hydrogen sulphide
(H2S). Measures % LEL flammable, % O2, ppm CO & H2S. Intrinsically safe
EEx ia T4 rated (Australian Approved). Confined space entry kit includes
sampling pump, tubing, filters and carry case. Designed to test confined
spaces from a safe area prior to entry. Supplied in carry case complete with
training video and battery charger. Other sensor options available at extra
cost. Battery pack run time 8h (18h with lithium batteries).

126
GAS ANALYSIS
Gas Analysis & Monitoring
GasCheck 3000 Portable General-purpose Leak Detector
ION,GASCHECK3000 AU
Portable leak detector. Micro thermal-conductivity sensor for high-sensitivity
detection of gases with a thermal conductivity different to that of air, including
helium, carbon dioxide, refrigerants, sulphur hexafluoride, natural gas, etc in
five groups. Direct reading of leak rate in ml/s with audio and visible signals.
Detection limit for helium 2E-5ml/s. Battery powered.
RAE Systems Minirae 2000 Portable PID
RAE,MR2000 AU
Portable handheld VOC (Volatile Organic Compound) monitor with data
logging. 3-D PID sensor (Photo-Ionisation Detector) fitted with 10.6eV lamp.
Ranges 0~999ppm (resolution 0.1) or 100~10,000ppm (resolution 1) VOC
expressed as isobutylene. Built-in correction factors for 102 compounds
from a total standard library of 250. Integrated pump for local or remote
(30m) sampling, with stall protection against liquid ingress. Downloadable
data logging for 1,500 points with time, data and header. Intrinsically safe.
Up to 10h operation with rechargeable (NiMH) or alkaline batteries.

>>Did you know….


You can obtain
quotes online,
quickly and
easily, with our
personalised Novatech O2 and CO2 Analyser/Transmitter
quoting system? NOV,1637-5
Oxygen and carbon dioxide analyser for packaging atmosphere, general
AU

industrial and research use. Oxygen sensor reading 1ppm to 100% with
1% accuracy. NDIR carbon dioxide analysis 0~100% ±3% of full scale. 2
Visit our websites, x 4~20mA outputs, 1 common & 3 selectable alarm relays. Gas connection
1/8 Swagelok. Flow rate with internal pump 100~500cc/min. AC operation.
browse the ISC MDU420 Logging Methane Monitor
catalogue and ISC,MDU420
Dual-range methane monitor with non-dispersive infrared sensor. Low range
AU

select the 0~100% LEL, and auto-range 0~100% methane by volume. Internal pump
for ambient air or stream sampling. Datalogging included, with software and

products you are cable for download. Supplied with 450mm stainless steel probe for flue gas
analysis. Rechargeable, with alkaline-battery pack as backup.

interested in – it > NEW


Odalog NO2 & CO Area Monitor for vehicle-parks & IAQ
couldn’t be easier. APT,ODA6000CP
Portable multi-gas monitor for area air-quality measurement, logging
AU

or personal monitoring in car-parks, loading areas and related zones.


Configured for carbon monoxide (from petrol vehicles) and nitrogen
www.techrentals.com.au dioxide (from diesel vehicles). Ranges CO 0~500ppm (to 1ppm) and NO2
0~50ppm (to 0.1ppm). Dust and water sealed to IP66, and rated intrinsically
www.techrentals.co.nz safe for general or mines use. Logging memory 500K readings. Integral
infrared communications interface, with software and IrDA USB adaptor for
www.techrentals.com.my configuration and download. Rechargeable, approximately 7 days operation
on full charge.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 127
GENERAL ENVIRONMENTAL
Electrochemistry, Water Quality

> NEW
Anton Paar DMA 35N Portable Density Meter
PAA,DMA35N au
TPS WP-88 Turbidity & Temperature Meter with 8m Cable
TPS,WP88
Portable hand-held turbidity and temperature meter for field or laboratory
AU

Portable density, specific gravity & concentration meter. Measuring range use. Sensor probe diameter 45mm, with 8m cable. Turbidity ranging 0.1~
0.000~1.999 g/cc and 0.0~40.0ºC. Built-in pipette style pump for sample 200/2000NTU ±1NTU with autoselection. Temperature compensation and
aspiration, with port for optional syringe-filling. Display of specific gravity, sensor range 0~ 60ºC ±0.1ºC. Case water resistant to IP67, connectors to
ºBrix, ºBaumé, %alcohol, proof, ºPlato, API, or %H2SO4. Rated intrinsically IP65, with detachable cable and sensor. Menu driven, with alphanumeric
safe [ATEX] for use with batteries, petrochemicals and solvents. Data storage display. Auto storage of time, date and results of last calibration for GLP.
of up to 1024 results, with recall, and infrared port for RS232 download to RS232C interface, and memory for 150 readings of data, time and date,
serial printer or PC. Wetted parts glass and PTFE. Battery powered. for Notepad results collection, or for AutoLog results collection with logging
intervals between 1min and 24h. Rechargeable NiMH battery gives up to
50h operation. Supplied with download-software, charger and calibration
solutions.

> NEW
TPS WP-80 pH and Temperature Meter
TPS,WP-80 au
Portable hand-held meter for pH, mV and temperature. Supplied with
combination pH electrode and separate temperature sensor on 1m cables.
Operating ranges 0.00~14.00pH and -10.0~120.0ºC [automatic sensor TPS WP-82 Dissolved Oxygen Meter
recognition with auto pH correction 0~100ºC]. Case water resistant to IP67, TPS,WP82 AU
connectors to IP65. Menu driven, with alphanumeric display. Auto storage Portable hand-held dissolved oxygen and temperature meter. Operating
of time and date of last calibration for GLP. Memory for 2400 readings of ranges 0~20ppm, 0~240% saturation, 0~45% gaseous and ppm with salinity
data, time and date, for Notepad results collection, or for AutoLog with correction. temperature range -10~120OC. Case water resistant to IP67,
logging intervals between 1 sec and 90 hr. Fitted with RS232C interface connectors to IP65, with 3m detachable cable and ED1 electrode. Menu
and supplied with download-software, charger and solutions. Rechargeable driven, with alphanumeric display. Auto storage of time and date of last
NiMH battery gives up to 50 hr operation. calibration for GLP. RS232C interface, and memory for 150 readings of
data, time and date, for Notepad results collection, or for AutoLog results
collection with logging intervals between 1min & 24h. Rechargeable NiMH
battery gives up to 75h operation. Supplied with download-software, charger
and solutions.

TPS LC80A Portable pH Meter


TPS,LC80A AU
Battery operated with LCD display. Automatic temperature compensation,
and analogue recorder output. Complete with combination electrode/
temperature probe with a max temperature of 60OC. Display has ranges:
0~14Ph, 0~199mV, & -10~199OC.
TPS Redox Electrode
TPS,REDOX AU
Silver/chloride Redox electrode for use with TPS LC80A Ph meter. Supplied
with 2 bottles of Zobell solution for calibration. 1:1 dilution gives approx.
231mV.

128
GENERAL ENVIRONMENTAL
Electrochemistry, Water Quality
TPS WP-84 Conductivity Salinity Temperature Meter Hydrolab Quanta Multiprobe Water Quality Meter
TPS,WP-84 AU HYD,QT-MP-A AU
Portable hand-held meter for conductivity, TDS (Total Dissolved Solids) and Multi-parameter water quality analyser with 15m cable. Meter unit rated to
temperature. Automatic range selection with 5 ranges. Case water resistant NEMA6 (waterproof), with simultaneous parameter display, realtime manual
to IP67, connectors to IP65. Menu driven, with alphanumeric display for full- storage of 100 frames of data and SDI interface. Transmitter probe with
text prompting. Storage of time and date of last calibration for GLP. Memory sample circulator, fitted with sensors for temperature, specific conductance/
for 150 readings of data, time and date, for Notepad results collection, or salinity, dissolved oxygen, pH, ORP and turbidity. Operates on 3 x C size
for AutoLog results collection with logging intervals between 1min & 24h. batteries.
Rechargeable NiMH battery gives up to 75h operation. Supplied with sensor
(k=1), charger and solutions.

TPS Water Quality Meter


TPS,90FL-T AU
YSI 55D Dissolved Oxygen Meter
Field meter and logger for water quality measurements. Configured with
YSI,55D NZ
independent probes for pH, conductivity/salinity[TDS]/temperature, dissolved
Measures dissolved oxygen in mg/L or percent saturation. Range is 0~20mg/
oxygen[DO] and turbidity. Cables 5m with probe holder and safety harness.
L, resolution is 0.01mg/L, accuracy is 0.3mg/L. Provides simultaneous
LCD display readout with simultaneous display of all measurements.
readings of O2 & OC. Dissolved O2 readings are automatically compensated
Manual, “notepad” storage or automated data logging for up to 1,808 sets
for temperature. Offering push-button calibration with a built-in calibration
of readings by time and date. RS232C interface, with WinTPS software
chamber, direct salinity, and altitude compensation. Supplied with 3m cable
included. Supplied with rechargeable battery, and clip-lead for operation
to probe.
from a 12V source such as a car-battery.
YSI 550A Dissolved Oxygen Meter with 12ft Cable
YSI,550A NZ
Handheld microprocessor based dissolved oxygen meter for use in fresh
water, sea water or polluted water. Range 0~50mg/l resolution is 0.01 or
0.1. Air saturation range is 0~500% resolution is 0.1 or 1 air saturation.
Temperature range is -5°C~45°C resolution is 0.1. Features: Self-diagnostics
on power up. Compensation for altitude, salinity & temperature, waterproof
to IP-67, push-button calibration, built-in calibration cha mber. Over 2,000h
(alkaline) battery life at 25°C. Supplied with 4m probe lead.
YSI 63 pH Salinity and Conductivity Meter
YSI,63-10 NZ
Measures temperature, pH, conductivity, and salinity. Ranges are: 0~14pH,
resolution 0.01, conductivity is 0~200mS/cm over 4 ranges, salinity is
0~80 ppt, resolution 0.1, temperature is -5~75OC, resolution 0.1. Stores
50 readings with ID, user-selected scale or autoranging for conductivity. Hanna Portable Turbidity Meter with Case & Kit
Supplied with a 15m cable to probe. HAN,HI93703C AU
Microprocessor-based, portable turbidity meter operating in the range 0~
Horiba U-20 Multi-function Water Quality Meter 50FTU x 0.01FTU or 50~1,000FTU x 1FTU(NTU). Long-life IR LED source
HOR,U-20XD1 AU
peaking at 890 nm for reduced colour-interference. Compliant with ISO7027
Multi-parameter water quality monitor with 30m cable. Waterproof Meter
requirements. Unique GLP feature allows automatic storage and recall
unit rated to IP67 with LCD display, analog output and RS232C interface for
of last calibration value with time and date. Supplied in carry-case with
data download using software supplied. Detachable probe, 47mmØ with
measuring cuvettes, and maintenance kit. Battery operation.
stainless steel cover suitable for use in 50mm wells, with sensors for pH/
ORP, dissolved oxygen, conductivity/salinity/TDS/seawater specific gravity,
temperature, turbidity and depth. Data logging up to 1m @ 15min intervals.
Alkaline battery operation.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 129
GENERAL ENVIRONMENTAL
Electrochemistry, Water Quality
Analite NEP160-1 Turbidity Meter Spectronic Helios Epsilon Spectrophotometer Visible
ANA,NEP160 NZ SUV,EPSILON1 AU
Portable turbidity meter suitable for potable or waste water measurements Single beam visible spectrophotometer, 325~1,000nm with 8nm bandwidth,
depending on the probe type. Supplied with either NEP280 100~20,000NTU operating in the range -0.1~2.5A. Wide view-angle LCD display and
waste water retro-scatter probe on a 5m cable or NEP260 0~3,000NTU sealed membrane keypad with push button auto-zero. Sealed optics,
potable water probe with 25m cable. Display resolution for the NEP280 with wavelength slew >4500nm/min. Operational modes absorbance,
probe is 10NTU, NEP260 probe is 1NTU. Repeatability is ±2% +1 digit on transmission, concentration and factor. Supplied with standard cellholder
all ranges. Data logging up to 100 time & date stamped readings with sample for 10mm square cells. RS232C port for computer and parallel interface
intervals from 1s~90min. Analogue output with a range of 0~2V fs on any for printer.
range. RS232C interface which can output readings on request or at preset
intervals from 1~99s or min.
DKK TOA Model RC-24P Portable Residual Chlorine Meter
DKK,RC-24P-DP AU
Portable, direct-reading residual chlorine meter for water analysis. Range
0~2mg/L [ppm]. Reagent-free measurement with electrode, 3m cable, float
and sample container for in-situ or grab-sampling. Compatible with direct
chlorination, hypochlorite or dichloroisocyanurate dosing. Calibration data
stored in electrode with correlation with DPD methods. Waterproof to IP67.
ISO validation functions, storage of 300 measurements and RS232 printer
output. Battery operated.

Van Essen Depth/Temperature Groundwater Logger 30M


VAN,TD30 AU
Groundwater depth and temperature logger for operation to 30m. Independent
probe 22mmØ x 125mm long with internal memory for 2 x 24,000 measurements,
battery-life 8~10y. Reader for set-up and download of data using standard
computer. Supplied with “Baro Diver” - ambient/surface logger for atmospheric
pressure correction.

Aquafluor Handheld Fluorimeter for Rhodamine WT &


Fluorescein
TUR,AQF-RF AU
Dual-channel handheld field fluorimeter. Configured for water-tracing by detection
of rhodamine WT and fluorescein dyes, detection limit ~0.4ppb. RWT channel
excitation 540nm, emission >570nm; Fluorescein channel excitation 475nm,
emission 515nm. Internal data logging for 1000 data points, with download.
Battery operated.

Isco 6700 Series Water Sampler with Bubbler Flow Module


ISK,6700-730 AU
Advanced water sampler for fully programmed collection. Samples can
be collected in 1, 2, 8, or 24 glass or plastic sample containers based on
time, flow, and/or parameter set points. Fitted with NEMA 4X,6 (IP67) sealed
controller featuring an exclusive, built-in pump, flash memory for easy
programming changes, and a plug-in module port for connection of a flow
meter module or parameter measurement module to enhance monitoring
capabilities. Provided with bubbler flow module. Sample bottles available.
Run from rechargeable 12V sealed batteries.

130
GENERAL ENVIRONMENTAL
Spectroscopy
Shimadzu UV-Mini 1240 Spectrophotometer UV-Visible X-Rite SP60 Portable Sphere Colour Spectrophotometer
SHI,UV-1240 AU XRI,SP60 AU
Single beam scanning UV-visible spectrophotometer, 190~1,100nm with Portable spectrophotometer for surface colour measurements. Diffuse
5nm bandwidth. Large LCD display for on-screen viewing of results, 8O [d/8] optical geometry with fixed 8mm aperture. Tungsten source
calibration curves and spectra. Standard applications include photometric for illuminant types C, D50, D65, D75, A, F2, F7, F11 & F12. Standard
measurement, spectrum scanning and quantitation. IC data card system for observers 2 & 10O. Blue-enhanced photodiode detectors with spectral
storage of raw data, methods and results, with optional program packs for range 400~700nm. Measures opacity and colour by chromatic, apparent
additional applications. Interface ports for printer or computer. 220~240V, or tristimulus calculation, with simultaneous included and excluded specular
50/60Hz. component, and spectrum at 10nm intervals. Storage of up to 2,000 samples
with results download to serial printer or computer. Operation from internal
rechargeable battery or ac adaptor.

Spectronic Helios Epsilon Spectrophotometer Visible


SUV,EPSILON1 AU
Single beam visible spectrophotometer, 325~1,000nm with 8nm bandwidth,
operating in the range -0.1~2.5A. Wide view-angle LCD display and
sealed membrane keypad with push button auto-zero. Sealed optics,
with wavelength slew >4500nm/min. Operational modes absorbance,
transmission, concentration and factor. Supplied with standard cellholder
for 10mm square cells. RS232C port for computer and parallel interface
for printer.

Materials Testing

> NEW
Anton Paar DMA 35N Portable Density Meter
PAA,DMA35N au
Hydramotion Viscolite 700 Portable Viscometer
HYL,V700S-21
Advanced portable viscometer with stainless-steel probe. Operating range
AU

Portable density, specific gravity & concentration meter. Measuring range 0.1~10,000mPaps (cps) with integral temperature correction -40~150ºC.
0.000~1.999g/cc and 0.0~40.0ºC. Built-in pipette style pump for sample Probe tip 21mmØ, immersion length 115mm (viscosity only) or 145mm
aspiration, with port for optional syringe-filling. Display of specific gravity, (viscosity/temperature). Acetal polymer probe base for handheld or clamped
ºBrix, ºBaumé, %alcohol, proof, ºPlato, API, or %H2SO4. Rated intrinsically operation, with coiled-cable connection to meter unit with 5 digit display.
safe [ATEX] for use with batteries, petrochemicals and solvents. Data storage Battery powered.
of up to 1024 results, with recall, and infrared port for RS232 download to
serial printer or PC. Wetted parts glass and PTFE. Battery powered.

AUSTRALIA NEW ZEALAND MALAYSIA


1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 131
>>Did you know….
You can register
online to receive
advance notice
of new products,
promotions and
technical news?

Visit our website


and register
today.

www.techrentals.com.au
www.techrentals.co.nz
www.techrentals.com.my
CALIBRATION
CALIBRATION
Calibration services. Online. Ontime. Everytime.

TR Corporation services also include calibration. These services


are delivered through TECHRENTALS and VMS.
Our laboratories are staffed by experienced technical engineers
and technical officers to provide internationally recognised calibration
services. Utilising state-of-the-art specialised instrumentation, each
is NATA accredited, with ISO quality systems in place for traceability
and control.

Industries supported:
• Aviation
• Defence
• Electrical
• Electronic
• Biomedical
• Mechaical
• Telecommunications

Why deal with us:


Our services: • Experienced,
qualified staff
• Calibration • NATA accreditation
• Repairs • ISO Quality control
• Sales • 22 convenient
• Total asset locations
management • Online services
(Australia only)
• Mobile calibration
facilities • One stop shop
facility for all your
calibration needs

Talk to your
TECHRENTALS
consultant
about how we
can help solve
your calibration
problems

134
GENERAL INDEX
A Charge Amplifier 88-89 Power Quality 48-54, 56 High Voltage Insulation Dielectrics
AC See Electrical Chart Recorder 76, 82-83 Protection Relay Test 57 Test Set 42
Accelerometer 88-89 Circuit Breaker Analyser 58 VLF Test 59 Hi-Pot Tester 46, 59
Acoustic Spectrum Analysis 119 Circuit Tracer 36 Electrical Power Quality Holiday Detector 91
Adhesion Tester 91 Clean Room Monitor 117 Demand Analyser 51-54, 56 Hot Wire Anemometer 113-114, 116
Air Cleaver - Fibre Optic 35 Harmonics 48-49, 51, 56 Humidity
Compressor Output 112 Coating Thickness 90-92 Power Factor 48-49, 51, 53-54, 63 Chamber 101
Flow 112-117 Coil & Winding Test 41, 46 Power Quality Analyser 48-50, 53-56 Concrete 92
Quality 113-115, 117 Combustion Gas Analysis 123-126 Voltage Current Recorder 76 High Temp Probe 77, 83-84
Air Conditioning Communications Test Set 21 Electrical Power Sources Indoor Air 113-114, 117
Coolant Flow 110, 112 Compressed Air Flow 112 Current Injectors 65 Logging 70, 72-73
Electronic Manifold 118 Compressor Output Generator 68 Natural Gas 105
Measurement 113-114 Flow 105 Line Conditioners 66 Recorders 102
Valve Balancing 118 Quality 105 UPS 66-67 Thermohygrograph 102
Air Quality Concrete Testing Electrical Testers 63 Transducer 77, 83-84
Monitoring 113-115, 117, 126 Adhesion 91 Electrical Transducers 60, 62 Weather 118
Particles 113-114, 117 Cover Meter 92 Electrochemistry 128 HVAC & IAQ 112-117
Temperature & Humidity 113-114, 117 Moisture Meter 92-93 Electrometer 5 Hybrid Recorders 76
Air Velocity Meter 112, 115 Reo Depth 92-93 Electrostatic Charge Measurement 6 Hydraulic Pressure 91, 94-95, 99-100
Alcohol Breath Analyser 122 Test Hammer 92-93 EMC/EMI Test Equipment 21
I
Alignment 88-89 Ultrasonic Tester 91-92 Endoscopes 79-81
Illuminance Meter 119
Ammeter 60, 62 Conductivity & Salinity 129 Environmental Chambers/Oven 100-101
Inclinometer 84
Amplifier Instrumentation 73 Confined Space Entry 123, 126 Environmental Noise 120, 122
Indoor Air Quality 113-114, 117
Anemometer 113-115, 116 Counting Scales 87 Ethernet Analyser 29-30
Infrared Camera 104-105
Angle Measurement 63 Crane Scales 86
F Infrared Thermometer 102-103
Antenna & Cable Test 18-19 Current
Fibre Optic Microscope 35 Injection Test Set 65
Antennas 19-20, 37 Clamp 46, 53-54, 57, 60-65, 75
Fibre Optics 33-34 Instrumentation Amplifier 73, 76
Appliance Tester 46-47 DC Source 7
Fusion Splicer 35 Insulation Tester 41-45, 59, 65
Area Heat Stress 113-114, 117 Injection 65
LAN Cable Test 32 Intrinsically Safe
Audio Analyser 26 Input Logger 70, 73
OTDR 34 Current Loop Calibrator 94-95, 98
Autoclave Logger 70, 73 Loop 94-95, 96-98
PMD 35 Digital Multimeter 6
Automotive Testing 90 Meter 48-49, 56, 60, 62-63, 110-111
Power Meter/Light Source 33-35 Gas Monitor 126
Primary Injection 65
B Field Strength Meter Moisture Analyser 105
Probe 4, 61-62
Balances 85, 87 Gauss 40 Noise Dose Meter 120-121
Secondary Injection 65
Balancing Machinery 118 RF 19-20 Photo-Ionisation Detector (PID) 123, 127
Sensor 75
Balancing Machinery Analyser 88 Field Strength Meters & Antennas 19-20 Inverter 68
Shunt 60, 63
Balometer 113-114, 115 Filters 26 Ionisation Tester 59
Transducer 53, 60, 63, 75
Barometric 102 Flash Card 75 ISDN 28, 31
Transformer (CT) 48-49, 51, 56, 60
Barometric Recorder 102 Flaw Detector 90
L
Bath D Floor Slip Tester 122
Laboratory Oven 101
Constant Temperature 94-95, 97 Data Communications Flow Meters 110-112
LAN
Ultrasonic 100 Cable Test 32 Compressed Air 110, 112
Analyser 29-31
Bit Error Rate (BERT) 28 Etherscope 29 Doppler 110-112
Cable Certification 32
Blast Logger 90 Fibre Optics 33 Gas 110, 112
Cable Tester 32
Body Vibration Measurement 88-89 LAN Analyser 29 Liquid 110-112
Laser
Bore Hole Depth 130 Protocol analyser 31 Non-Intrusive 110-112
Distance & Speed 78
Bore Hole Water Quality 129 Protocol Analyser 28, 30-31 Open Channel 110-112
Level 78
Borescope 79, 81 WAN analyser 31 Transit Time 110, 112
LCR Meter 9
Brake Tester 90 WAN Analyser 29, 31 Ultrasonic 110-112
Leak Detector
Bridge LCR 9 Data Logger 70-73, 83 Flue Gas Analysis 123-125
Gas Pipe 37, 118, 125, 127
DC High Voltage 4, 59 Flue Inspection 79-80
C Microwave Oven 19-20
DC Power Supplies 7 Fluorimeter 130
Cable Refrigerant 118
Decade Resistance Box 9 Force Gauge 84
Fault Locator 36-37 Water 37
Demand Analyser 48-49, 51, 56 Formaldehyde Meter 123, 125
LAN Test 32 Light Measurement 119
Density Meter 86, 128, 131 Frequency Counter 12
Locator 32, 36-37 Light Meter 119
Depth Logger 130 Frequency Response Analysers 10
Tester 32, 36-37 Linear Position Transducer 84
Dewpoint 105, 113-114, 117 Frequency Transducer 60, 63
Tracer 36-37 Load Cell 85-86
Digital Camera 106 Function Generator 8
Cable Locator 36 Logger 70
Digital Storage Oscilloscope 2 Fusion Splicer 35
Cable Tester 36 Accessories 71
Dimension Measurement 78
Cable TV 27 G Autoclave 70, 73
Dissolved Oxygen 128-129
Calibrator Gamma Radiation 19-20 Data 70-73, 83
Distance Measurement 78
Current 94-97 Gas Environmental Noise 120, 122
Distortion Analyser/Generator 26
Current Loop 94-96, 98 Alcohol 122 Explosion 90
Dose Meter (Noise) 120-121
Dry Block Temperature 94-95, 97-98 Carbon Dioxide (CO2) 117, 124-127 Flow 110-111
Dust Measurement 113-114, 117
Electrical 9 Carbon Monoxide (CO) 117, 123-127 Ground Vibration 90
Hydraulic 94-95, 99-100 E Flammable (LEL) 125-126 Humidity 70, 72-73
Industrial 94-95 E1/E3 Tester 28-31 Formaldehyde 123, 125 Oven 70
Loop 94-95 Earth Leakage 41- 45, 48-49, 59-60, 62, 65 Hydrogen Sulphide (H2S) 125-126 Pressure 102
Pneumatic Instruments 94-95, 98 Earth Tester 46 Methane (CH4) 123, 125-127 Shipping & Transport 89
Pressure 94-95, 98-100 Electric Motor Test 46 Nitric Oxide (NO) 117, 123-126 Temperature 70-73
Process 94-96 Electrical 40 Nitrogen Dioxide (NO2) 123-127 Logic Analyser 10
Resistance 94-96 Electrical Cable Test 41-45, 59 Oxygen (O2) 123, 126-127 Logic Programmer 10
Temperature 94-95, 97-98 High Voltage 59, 65 Ozone (O3) 125 Low Frequency
Voltage 94-96, 98-99 Surge Generator 36 Refrigerant 118 Frequency Response Analysers 10
Caliper 78 TDR 36 Sulphur Dioxide (SO2) 123 Signal Generator 26
Camera VLF 59 VOC 123, 127 Luminance Meter 119
Digital 106 Electrical Installation & Test Gas Analysis & Lux Meter 119
Endoscope 79, 81 Appliance Tester 46-47 Monitoring 123, 125-127
M
High Speed 82 Earth Leakage (RCD) Gauss/Tesla Meter 40
Machinery
Pipe Inspection 79-81 41-46, 48-49, 60, 62, 65 Generator (AC) 68
Balancing 88
Surveillance 106 High Voltage Test (Hi-Pot) 46, 59 Glossmeter 90
Vibration 88-89
Thermal Imaging 104-105 Insulation Test 40-45, 59 GPIB Interface 4
Magnetic Field Meter 40
Video 82 Phase Rotation 63 Ground Vibration 90
Manometer 114-115
Carbon Dioxide (CO2) Resistance Test 41-45, 46 Groundwater 130
Materials Testing 86, 128, 131
113-114, 117, 124-127 Soil/Ground Resistance 41, 45-46
H Memory Recorder 73-75
Carbon Monoxide (CO) Electrical Power Generation
Hardness Tester 93 Metal Detector 106-107
113-114, 117, 124-126 & Transmission
Harmonics (Power) 48-50, 56 Methane Monitor 123, 127
Cat 5, 5E, 6 32 Current Injection 65
Heat Stress 113-114, 117 Micro-Ohm Meter 41-43
CCTV Surveillance 106 High Voltage Test (Hi-Pot) 59
AUSTRALIA NEW ZEALAND MALAYSIA
1800 632 652 0800 832 473 603 5632 1135
www.techrentals.com.au www.techrentals.co.nz www.techrentals.com.my 135
GENERAL INDEX
Microscope 82 Transducer 77, 83 Sound 120 Vane Anemometer 113-115
Microwave Leakage Detector 19-20 Probe Dose Meter 120-121 Variacs 67
Microwave Oven Survey Meter 19-20 Current 4, 48-51, 57, 61-62 Logger 120-122 VCR 82, 106
Modified Atmosphere Digital 75 Measurement 120 Vibration
Packaging Test 123, 127 Frame Relay 31 Signal Analysis 119 Accelerometer 88-89
Modulation Meter 20 High Voltage 4 Sound Level Meter 88-89, 120-122 Analyser 88-89
Moisture Line Logic 75 Vibration 88-89 Blast Logging 90
Concrete 92-93 Static Detector 6 Spectrophotometer 130-131 Impact Hammer 89
Timber 92 Process Calibrator 96-98 Spectroscopy 131 Logging 89-90
Moisture Balance 87 Programmer Spectrum Analyser Table 88, 90
Multimeter 5-6 EPROM, EEPROM 10 Acoustic 119 Transport Testing 89
Protection Relay Test 57 Optical 35 Whole Body 88
N
Protocol Analyser 28, 30-31 RF 10, 14-15, 17 Video
Natural Gas 105
Pulse Crest Meter 91 Speed Measurement 78 Endoscope 81
Network Analyser
Pulse Generator 9 Splicer - Fibre Optic 35 High Speed 82
Antenna & Cable Test 18-19
Pulse Porosity Detector 91 SS7 28 Microscope 82
LAN/WAN 29
Pump 94-95, 98-100 Startup Current 48-49, 51-54 Pipeline Inspection 79-81
Power 48-49
Static Detector Probe 6 Video Camera
RF 13, 18, 26 R
Static Discharge Generator 21 Digital 106
Telecommunications 28 Radar Speed Gun 78
Step Transformer 21 VHS 82, 106
Noise & Sound 120 Radiation Monitor 19-20
STM1 ... STM65 28, 31 Video Security 106
Noise Dose Meter 120-121 Radiometer 119
Strip Chart Recorder 76 Viscometer 86, 131
Noise Logger 120, 122 Random Noise Generator 26
Stroboscopes 78-79 VLF MV Cable Test 59
Non-Destructive Testing RCD Test 41, 45
Surface Roughness 91 Volatile Organic Compounds
(NDT) 88, 90-92 Recorders 70
Surge Generator 36 (VOC) 123, 127
Non-Storage Oscilloscope 3 Barometric 102
Surge Transient Generator Voltage Calibrator 94-95
Chart 76, 82-83
O EMC/EMI Test 21 Voltage Transducer 60, 62
Hybrid 76
Occupational Health & Safety 119, 122 Survey Equipment 78 Voltmeter 6, 22
Memory 73-75
Air Quality 113-114, 117 Sweep Generator 13
Pressure 82, 83 W
Appliance Testing 46-47
Tape 76 T Walk Through Metal Detector 106
Confined Space Entry 123, 125-126
Temperature Humidity 72 Tachometers 78-79 WAN Analysers 29-31
Floor Slip Tester 122
Rectifier 7 Tape Recorders 76 Water
Formaldehyde 123, 125
Refrigerant Leak Detection 118 TDR 36-37 Analysis 130
Heat Stress 113-114, 117
Relative Humidity 102 Telecommunications Conductivity 129
Lighting 119
Also See Humidity BERT 28 Depth 110-111, 129-130
Noise & Sound 120
Relay Test 57, 65 CDMA 23 Flow 110-111
Ozone 123, 125
Resistance Communications Analyser 28 Leakage Detection 37
Radiation 19-20
Calibration 94-95 Fibre Optics 33-34 pH 128-129
Toxic Gas 123, 125, 127
Decade 9 GSM 28 Quality 128-129
UV Exposure 119
Ground/Soil 45-46 ISDN 28 Sampling 130
Vibration 88
Micro-Ohm 41-43 PDH 28 Water/Oil Bath Temp Calibrator 94-95, 97
Oil Insulation Tester 41, 46
Static 41, 46 POTS 28 Waveform Generator 8
Optical Networking
Tester 41-46 SDH 28 WBGT 113-114, 117
DWDM 35
Retail Traffic Flow Counter 107 Signalling Analyser 28 Weather 118
Optical Spectrum Analysis 35
RF & Microwave System Tools 28 Wind Speed & Direction 117-118
Oscilloscopes
Accessories 26 WAN analyser 31 Workplace Safety
Digital Storage 2-3
Amplifier 13 W-CDMA 23 See Occupational Health & Safety
Non Storage 3
Antenna/SWR 18-19 Temperature
Portable 2-3 X
Antennas 18-20 IR Thermometer 102-103
Probes 4 X.21, X.24 30-31
Attenuator 25-26 Logging 72-73, 130
OTDR 34 X-Ray Measurement 19-20
Communications Test Set 21 Recorders 102
Oven 101
EMC/EMI Test 14, 17, 20-21 Thermocouple 102-103
Oven Logger 70
Field Strength Meters 19-20 Thermometer 102-103
Oxygen & CO2 Analyser 123, 125, 127
Frequency Counter 12 Tension 85
Oxygen (O2) 123, 125, 127
Function Generator 8 Thermal Imaging Camera 104-105
Ozone (O3) 123
Modulation Meter 20 Thermocouple 102-103
Ozone Monitor 123
Network Analyser 13, 18-19 Thermohygrograph 102
P Power Meter 22-23 Time Domain Reflector
Particle Counter 113-114, 117 Power Sensors 24 TDR 36-37
PAT 46, 47 Radiation Monitor 19-20 Token Ring Analyser 30
PCM Test Equipment 28 Sensor 22, 24 Torque Wrench 84
PDH Analyser 28 Signal Generator 13, 20 Total Dissolved Solids (TDS) 129
People Counter 107 Spectrum Analyser 10, 14, 17 Toxic Gas Monitor 123, 125, 127
Petrol Generator 68 Sweep Generator 13 Transducers
pH Measurement 128 Voltmeter 22 Current 53, 60, 63
Phase Angle 63 Rogowski Coil 48-49, 53 Electrical 60, 62
Phase Rotation Meter 63 Rotating Balancing 89 Frequency 60-63
Phase Sequence Meter 63 Rotating Laser Level 78 Humidity 77, 83-84
Photo-Ionisation Detector (PID) 123, 127 Roughness 91 Instrument Transformer 60, 62
Pinhole Detector 91 Router Test System 31 Position 84
Pipe Locators 36 RTD Calibrator 94-95 Pressure 77, 82-83
Pipeline Inspection 79 Temperature 77, 83-84
S
Pitot Tube 115 Voltage 60, 62-63
Salinity & Conductivity 129
Plotter Printer 76 Transformer Oil Test 46
Scales 85-87
Polarisation Mode Dispersion (PMD) 35 Transient Burst 21
Scopemeter 2-3
Portable Appliance Tester 46, 47 Transport
Security
Position Transducer 84 Inclinometers 84
Bug Detector 106
POTS 28 Turbidity 128-130
Metal Detector 106
Power See Electrical TV Test Equipment 27
Surveillance 106
Power Analyser 48-49, 51-56, 63
Shaft Alignment 88-89 U
Power Demand
Shaker Table 88, 90 Ultrafine Particle Counter 113-114, 117
Analyser 48-49, 51-54, 56
Signal Generator Ultrasonic Bath 100
Power Disturbance 48-49, 51, 56
Low Frequency 26 Uninterruptable Power Supplies
Power Line Conditioner 66
RF 13 - UPS 66-67
Power Supplies - DC 7
Signalling Analyser 28 UV Exposure 119
Pressure
Smoke Generating Machine 114
Calibrator 94-95, 97-100 V
Sniffer 30
Circular Chart Recorder 82-83 V24, V35 31
Soil Resistivity 41, 46
Indicator/Gauge 77, 82-83 Valve Balancing (Air Conditioning) 118
Sonde 37

136
YOUR TRUSTED PARTNER IN TECHNOLOGY
OFFERING INNOVATIVE SOLUTIONS THROUGH
OUR LEADING BRANDS:
AUSTRALIA
1800 632 652
www.techrentals.com.au

NEW ZEALAND
0800 832 473
www.techrentals.co.nz

MALAYSIA
603 5632 1135
www.techrentals.com.my

YOUR TRUSTED PARTNER IN TECHNOLOGY.


OFFERING INNOVATIVE SOLUTIONS THROUGH OUR
LEADING BRANDS:

Das könnte Ihnen auch gefallen