Digital Satellite
SD & HD Broadcasting Signal Measuring
Meter With Spectrum
1680S / 1680S2
USER MANUAL
Table of Contents
1. Features 4
2. Safety Instructions 5
3. Preliminary remark 7
4. Operations 8
4-5-6-6. SW CONFIGURATION 28
4-6-1. How to saving the measured Data and uploading the file to the PC 32
Telemann Corporation
4-6-3. How to download the Satellite file list / LNB / Configuration
D-612, Dawoo Techno-Park, 187-7 file list / SW(Switch) Configuration file list from the PC to the Analyzer 34
Dodang-Dong, Wonmi-Gu, Bucheon-Si,
Gyeounggi-Do, R.O. Korea 5. Specifications 35
Tel : 82-32-678-8566
Fax : 82-32-678-8568 6. Warranty 38
E-Mail : info@telemannco.com
www.telemannco.com Version 1.2 (2008. 08) Warranty Card
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
6) Easy upload/download new satellite file list from PC using USB port
The user can upload/download new satellite file list from PC and transmit it to the unit using
HyperTerminal program in window system. Max. 99 satellites information (Max 2,560 TP) files
| 4 | | 5 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
Circumstances
• Use the analyzer in the temperature range from 5 to 50 ℃. Preliminary
Installation
3 remark
• Don’t connect any cables which are not offered by manufacturer.
쮡 It may cause fatal damage to the analyzer. 1. Check out the packing status.
• Only use the chargeable batteries, adapter and USB cable provided by manufacturer. Using 쮡 In case of damaging the packing box, contact to the dealer or service center. Keep the
unauthorized accessories could avoid warranty. damaged packing box as it is so that we can figure out the point of problem correctly.
3) For the 1680S, after discharging completely, it takes for more than 8 hours to fully recharge batteries.
쮡 The battery charging time is upon the battery status.
4) When the battery charge level becomes low and you hear the warning tone, you should recharge the
batteries. If the battery charge level becomes exceedingly low, the analyzer will automatically power off.
| 6 | | 7 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
4. Check out whether satellites and transponders are saved into the analyzer correctly.
| 8 | | 9 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
Move a dish until the position of satellite is found. When the analyzer detects the
correct position of satellite, “SERCHAING” message is changed to “FOUND”. When
NOTE!!!
the display is changed to “FOUND”, keep moving a dish until “S” (Signal Level) and
“Q” (Signal Quality) are peaked to the maximum value. The analyzer beep the higher
audible tone closer to the maximum level and lower beep sound more estrange from
1) LCD backlight On/Off the max level.
To turn on the LCD backlight, press enter button more than 2seconds. To turn off the LCD backlight, Signal tone is generated from over 40dB ㎶of the current level, but if the current level
same method.
is lower than 20dB lower than the peak level, signal tone will not be generated.
2) LCD Contrast Level Control
To adjust the contrast level of the analyzer, turn the analyzer off. Press the power button first and press When the max level is reached, fix the dish and LNB.
the enter button. Release the power button, then the mode of CONTRAST ADJUSTMENT is displayed. (If “S” value is only displayed not show “Q”, different satellite is found)
By pressing the Left/Right button to adjust the LCD contrast level and press enter button for saving.
Or, you can adjust the LCD CONTRAST level on the mode of SYSTEM SETUP.
3) When you want to initialize the analyzer To set the parameters of satellite, transponder frequency, polarity / signal band, transponder
Turn the analyzer off. Press the power button with pressing the left arrow button. Release the power name / channel name, level unit, Project name (local frequency and LNB current adjustment),
button. Then the mode of DEFAULT OPTION SETUP is displayed. By pressing the enter button, you can use the setting bar pressing the buttons (up/down/left/right/next/enter).
make the analyzer to the factory default settings.
Polarity/Signal Band
4-2. Antenna Adjustment Transponder Frequency Transponder
number/Channel Name
Press and hold the power button. The first screen shows
model name, battery charge percentage.
Level Unit
22KHz pulse/DiSEqC
Project name Battery balance
| 10 | | 11 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
NOTE!!!
D (Fine tune west) ; To move the antenna to the West slowly.
| 12 | | 13 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
The higher Q value shows the better signal. 4-5. Menu Screen
After checking the actual LNB current, press the finger button, and the Menu Screen shows
six menus. In order to select the desired menu, press the up/down/left /right button and
press the enter button to access the selected menu.
In any menu, you can access to the menu screen directly by pressing the finger button more
• MER : the higher value the better signal. Over 15dB is excellent signaling condition and than 2seconds.
minimum valid signal is 12dB.
• SNR: the higher value the better signal. Over 10dB is good signaling condition and
minimum valid signal is 8dB.
• Pre-BER: Before BER. Bit error rate before correcting by FEC.
• Post-BER: After BER. Bit error rate after correcting by FEC.
• BER value is marked as x.xE-x and lesser error bit of the total transmitting bit means better
signal. I.g, BER 4.0E-5 means 4X10(-5), 4bits are error on the 100,000bit. The Pre-BER
[1680S menu screen] [1680S2 menu screen]
should be more than x.xE-4.
NOTE!!!
NOTE!!!
In case of LNB power is over than 450mA by LNB defect Satellite Antenna Adjustment Digital Signal Quality LNB Current Measurement
Confirmation
or cable short circuit, the analyzer display OVER LOAD
with beep sound. Then, remove the cable and check the cable and LNB condition. 4-5-2. DUAL SAT MEASUREMENT
By pressing the finger button or the enter button on the Main menu, the
below mode is shown.
| 14 | | 15 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
By using the up/down/left/right arrow buttons, select the symbol rate for changing. The symbol
4-5-3. SCAN & DATA LOGGER rate range from 1M to 45M is selectable. And press the enter button for saving the value.
By pressing the finger button or the enter button on the Main menu, the
For a quick scan, the narrow setup of symbol rate is recommended.
below mode is shown.
You can scan all active transponders of the selected satellite which was saved in the 5) MIN. SCAN LEVEL
analyzer. And the review for the scanned transponders including the frequency, symbol To set up the minimum level for scaning, press the enter button.
rate, FEC, SNR and level is available. Then the black bar is moved to the right side from the whole line
covering.
To select the mode, press the up/down arrow buttons. After pressing the enter button, By using the up/down/left/right arrow buttons, select the level
select the value by using the arrow buttons, and press the enter button for saving. ㎶
number for changing. The range from 40 to 70dB by 5dB step or NONE is selectable. And press
To back to the Main menu, press the finger button. the enter button for saving the value.
2) TARGET LNB
To select the LNB, press the enter button. Then the black bar is moved to the right side from the 7) REVIEW SCAN LIST
whole line covering. Press the enter button, the [SELECT SCAN LIST] mode is shown.
By using the up/down/left/right arrow buttons, select the mode of 1st / 2nd / ALL. On the ALL mode, In case of no scanned list, [EMPTY SCAN LIST] is shown. Then press the finger button to back to
press the arrow button one more, then the modes of 1st / 2nd is shown. And press the enter button the higher mode.
for saving the value.
| 16 | | 17 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
In case of no SCAN file, [SIGNAL NOT FOUND] and [EMPTY SCAN LIST] is shown. Then press the Move a black bar to (A) or (B) or (C) position by using arrow buttons.
finger button to back to the higher mode.
(A) When a black bar is located on (A) position
9) REVIEW FILE a) Spectrum span adjustment
To watch the saved file, press the enter button. Then the [REVIEW FILE] is shown. By pressing the enter button, the underline is shown.
By pressing the finger button or the enter button, the mode is back to the higher mode.
The spectrum span adjustment is available by using the down arrow buttons.
10) UPLOAD ONE FILE FULL 쮡 600M 쮡 240M 쮡 120M
By pressing the up arrow button, the below span is available.
쮡 쮡 쮡
To select one file to upload to a PC, press the enter button. The [UPLOAD FILE] is shown.
By pressing the finger button or the enter button, the mode is back to the higher mode. 120M 240M 600M FULL
Press the enter button, the selected span is saved.
11) UPLOAD ALL FILE
To upload all files to PC at one time, press the enter button. The [UPLOAD ALL FILE] is shown. b) fast Spectrum sweep mode
When the “ Press ? Key to confirm” is displayed, press the enter button. Then all the file is Press the enter button twice quickly, the below spectrum screen is shown.
uploaded to the PC. The fast spectrum sweep mode helps the install an antenna with the quick feedback upon the
antenna positioning. (sweep speed: 300ms)
For the more details, refer to the [4-6 The up/downloading the file to a PC] On the standard level setup mode, by pressing the left/right
arrow buttons, the screen display unit is changed to
12) DELETE ONE FILE 5dB/2dB.
To select and delete one file, press the enter button. The [DELETE FILE] is shown. By pressing the
enter button, the file is deleted. (B) When a black bar is located on (B) position
After pressing the enter button, the underline is shown, by using the up/down buttons, the standard level
13) DELETE ALL FILE : ㎶
value is changed. (Level range; 15~110dB )
To delete all files at one time, press the enter button. The [DELETE ALL FILE] is shown. When the Press the enter button, the adjusted level value is saved.
“Press ? Key to confirm” is displayed, press the enter button. Then all the file is deleted.
| 18 | | 19 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
C) When a black bar is located on (C) position By changing the span at the mode marked single cursor or double cursor, the Local frequency is
The following modes (i~ vii) are changed by pressing the up/down buttons. became the center of cursors location or between two cursors.
i) V/LO mode (To setup the Spectrum group by switching LNB switch)
v) A B : A TO B = xxx.xMHz (Frequency band between A and B marker)
After pressing the enter button, the underline is shown. By
At the (B marker and its signal level) mode, (no pressing the enter
using the up/down buttons, the spectrums waveform by LNB
button), press the up arrow button, the below picture mode is
switching such as V/LO, H/LO, H/HI, V/HI.
displayed. Press the enter button, the underline is shown.
By pressing the enter button, the setup is completed. It is shown the Frequency distance between A marker and B
The channels spectrum waveform contained in the adjusted marker.
group is shown. It is displayed as A TO B = xxx.x MHz.
ii) (Single Marker) Pressing the left/light button, A cursor vertical line is moved left/light. By pressing the up/down
At the right below mode (V/LO), (no pressing the enter button), button, B cursor vertical line is moved left/light.
press the up arrow button, the Single Marker mode is displayed. By pressing the enter button, the setup is completed.
Press the enter button, the underline is shown. By pressing the
up/down/left/right buttons, the correspondence level is shown vi) or (Spectrum Sweep)
as the signal marker (vertical line) is moving between left and At the (Frequency band between A and B marker) mode, (no
right. pressing the enter button), press the up arrow button, the below
By pressing the enter button, the setup is completed. picture mode is displayed. Press the enter button, the underline
is shown.
iii) A B : A = xxxx.x:xx.xdB (A marker and its signal level)
The peak level and its frequency are displayed as PEAK
쮡 쮠
At the Single Marker mode, (no pressing the enter button), press
the up arrow button, the below picture mode is displayed. Press xxxx.x:xx.xdB means spectrum sweeps from the left to the right and means spectrum
the enter button, the underline is shown. sweeps from the right to the left.
There is display of frequency and signal level as A. Pressing the up/down/left/light button, the direction of spectrum sweep is changed.
Pressing the left/light button, A cursor vertical line is moved
By pressing the enter button, the setup is completed.
left/light. By pressing the up/down button, B cursor vertical line
is moved left/light.
vii) (Rotator Control)
By pressing the enter button, the setup is completed.
At the (Spectrum Sweep) mode, (no pressing the enter button),
press the up arrow button, the below picture mode is displayed.
iv) A B : B=xxxx.x:xx.xdB(B marker and its signal level)
Press the enter button, the underline is shown.
At the (A marker and its signal level) mode, (no pressing the
In spectrum mode, you can control a rotator to the
enter button), press the up arrow button, the below picture
East/West/original position.
mode is displayed. Press the enter button, the underline is
shown. By pressing left/light button, the rotator is moved to East/West slowly. By pressing up/down
There is display of frequency and signal level as B. button, the rotator is moved to East/West quickly. By pressing the finger button, the rotator is
Pressing the left/light button, A cursor vertical line is moved left/light. By pressing the up/down back to the original position.
button, B cursor vertical line is moved left/light.
By pressing the enter button, the setup is completed.
By pressing the enter button, the setup is completed.
| 20 | | 21 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
Specially DVB-S2 (HD) has the more symbol (8PSK) than SD level QPSK and it has more
interference influence. In this case, this mode shows the clue of the matter for finding
ⓑ LNB
By pressing the enter button, the programmed LNB lists are
correct point.
displayed. The user can select the desired LNB by using the
up/down button. Press the enter button for saving. The
maximum 70 LNBs are available.
4-5-6. SYSTEM CONFIGURATION
Press the enter button on the [SYSTEM CONFIGURATION] mode, the
below sub-menu are displayed.
ⓒ SW
It shows the programmed switch list by pressing the enter
button. Select the desired switch using the up/down buttons
and press the enter button for saving.
[MEMU]
The maximum 30 SWs are available.
4-5-6-1) SYSTEM SETUP
4-5-6-2) SATELLITE TP LIST
4-5-6-3) SATELLITE FILE LIST
4-5-6-4) USB PORT SETUP NOTE!!!
4-5-6-5) LNB CONFIGURATION
Please refer to the instruction of how to make update the project file list and on the
4-5-6-6) SW CONFIGURATION mode of [4-6. The up/downloading the file to a PC]
4-5-6-7) DiSEqC COMMAND LIST Please contact to the service center if there is required of adding the new file than the
programmed LNB and SWITCH in the analyzer.
| 22 | | 23 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
ⓔ LEVEL UNIT
After pressing the enter button and using the up/down/left/right buttons, Level unit is
㎶
selectable among dB , dBm or dBmV. (Default: dB ). ㎶ ⓛ LCD CONTRAST
By pressing the enter button, the value is saved. Press the enter button and adjust the LCD contrast level [1~9]
by using the up/down/left/right buttons. (Default: 7)
ⓕ MEASURE B/W-MHz
After pressing the enter button and select the digital level ⓜ BEEP SOUND
measurement bandwidth by using the left/right buttons. The Press the enter button and select the signal sound by using the up/down/left/right buttons.
bandwidth AUTO/3.0~26.0MHz are selectable. In case of -. CODE: If the searching Satellite, FEC and SR are correctly found, the analyzer sounds a high
AUTO, the analyzer measures the digital average power tone.
automatically upon the signal bandwidth. (Default: 3MHz). -. LEVEL: If the searching satellite is found, the analyzer sounds a tone. The responding speed
By pressing the enter button, the value is saved. is faster than the CODE mode.
-. OFF: No sound makes even the search is completed.
ⓖ CABLE-LOSS The default is CODE.
Cable Loss feature is to automatically compensate the measuring errors occurred when the
measuring cable has some loss or when you do measuring by connecting an impedance ⓝ BER RANGE
matching device to the input terminal. Press the enter button and select BER measure range [1.0E-6
Press the enter button and select the number by using left/right buttons. or 1.0E-8] by using the up/down/left/right buttons. 1.0E-6 is
The +0.0~+12.0 in 1GHz and 2 GHz can be selected. recommended for a quick measurement.
| 24 | | 25 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
ⓢ USER NAME To mark the S, the mode of LNB EDITABLE should be saved as YES on the SYSTEM
ⓚ
SETUP mode. Please refer to the mode of “ LNB EDITABLE” on the 4-5-6-1)
Press the enter button and put-in and save the user name. Press the left/right buttons to move SYSTEM SETUP.
the cursor and select the alphabet or number value by the up/down buttons. Maximum 16
letters are available. Press the enter button to save the value. 2) Then the satellite marked S will be ignored on the measurement or saving mode.
On the Default of USER NAME, the overwriting is available. Press the finger button to back to the superior menu.
2) To check the symbol rate and FEC, press the right arrow button. For more details, please refer to the following manual [The up/ downloading the file
to the PC].
3) To make the skip mode of selected frequency, press the enter button after moving the
black bar on the SKP column. Press the finger button to back to the superior menu.
ⓚ
To mark the S, the mode of LNB EDITABLE should be saved as YES on the SYSTEM Move the bar to the NAME mode and press the enter
SETUP mode. Please refer to the mode of [“ LNB EDITABLE” on the 4-5-6-1)
button, then the [SELECT LNB TYPE] mode is shown.
SYSTEM SETUP].
4) After the above process, the frequency marked S will be ignored on the measurement ① NAME : To select the desired LNB by pressing the enter button.
or saving mode. ② SW TYPE : To select the desired switch type by pressing the enter button.
Press the finger button to back to the superior menu. ③ LNB CONTROL : It shows the LNB control signal.
④ POLARITY : It shows the sort of LNB signal (RHCP/LHCP, Vert/Hori, Non-Pola)
| 26 | | 27 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
NOTE!!!
4-6. The up/ downloading the file to the PC
For the mode of [LNB CONTROL] and [POLARITY], manual change is not available as
it may commit the measurement error.
[Step 1 : Software Requirements]
To upload the Satellite file list or the measurement data files which was saved in the analyzer
Press the enter button to go to the sub-menu.
to the PC (Personal Computer), or update the files such as satellite list, LNB configure file or
Press the finger button to back to the superior menu. SW (Switch) configure file in the PC and download it to the analyzer, the below stipulated
software are need
① CP2102 USB to UART Bridge Controller driver
4-5-6-6) SW CONFIGURATION
To select the setup menus and change all related parameters.
② Hyper Terminal Software.
Please refer to the follow guide for CP2102 USB to UART Bridge Controller Driver and Hyper
Press the enter button to go to the sub-menu.
Terminal Software.
Move the bar to the NAME mode and press the enter
button, then the [SELECT SW TYPE] mode is shown.
[Step 2: Connect DIN-USB cable between the analyzer and the PC]
The DIN-USB cable is presented with the analyzer.
① NAME : Selectable the desired switch type. Please take the following procedure.
② CONTROL SIGNAL: It shows the Switch control signal. 1) Turn on the PC.
③ NUMBER OF PORT: It shows the Set switch port from 1 thru 8. 2) Connect the DIN-USB cable between the analyzer and the PC.
④ PORT 1~8 : It shows the config parameters for the selected switch port. 3) Turn on the Analyzer.
4) If the O/S (operation software) of the PC is the later version since then WINDOW2000/XP,
NOTE!!! the PC automatically searches the software of CP2102 USB to UART Bridge Controller and
installs it. Then please take the procedure from step 3.
For the mode of [CONTROL SIGNAL], [NUMBER OF PORT] and [PORT 1~8] manual
5) If the automatic installation is failed or the O/S of the PC is the prior version than
change is not available as it may commit the measurement error.
WINDOW98/SE, please install the driver manually as stipulated on the Step 2.
Press the finger button to back to the superior menu.
[Step 3: Install Driver]
1) Connect to the www.telemannco.com
쮡
4-5-6-7) DiSEqC COMMAND LIST
To check the DiSEqC commands and it can be changed for measurement condition. 2) Click the [DOWNLOAD] [Software].
3) Click the [CP2102 USB to UART Bridge Controller drivers for Windows]
Press the enter button to go to the sub-menu. 4) Download the suitable for your PC O/S system and install it.
In case of not working the DiSEqC switch, check whether the instruction word is rightly
adjusted. [Step 4: Checking for Comport]
쮡
1) Click the [My computer] [Properties (G)]
2) Click the [Device Manager] 쮡
Check the “+”symbol at the COM / LPT port.
3) If there is mode of [CP2102 USB to UART Bridge Controller], the installation is completed
well.
| 28 | | 29 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
2. Turn the computer on, and go to the HyperTerminal. Select [Start] 쮡 [Programs]쮡
쮡
[Accessories ] [Communications] 쮡 [HyperTerminal]. A large window will appear,
titled [New Connection] - [HyperTerminal]. A small window is titled Connection
Description and displays New Connection. Enter any appropriate name for the new
connection file and select any icon. File name can be descriptive, such as Test, low1,
TAB2, or ROOM3. Select OK. The HyperTerminal working window will now display the file
name in the title bar, followed by HyperTerminal. A small window will appear requesting
area code, phone number, etc. Skip all entry fields except Connect using. Select COM port
which is matched with your operating system. If you don’t know which COM port is
suitable for your system, click on [My Computer] 쮡 쮡
[Properties] 쮡
[Hardware]
[Device Manager] 쮡 [Ports]. You can see which port is for CP210x USB to UART Bridge
Controller.
NOTE!!!
HyperTerminal Software 3. Turn the analyzer on by pressing the POWER button, and go to SYSTEM CONFIGURATION
If you are using Windows 98/98SE/ME/2000/XP, HyperTerminal software is one of
basic programs. To start HyperTerminal go to the [Start Menu] 쮡
[Programs] 쮡 mode by pressing the FINGER button more than 2sec. Use the UP and DOWN button to
[Accessories]쮡 [Communications] 쮡 [HyperTerminal] (Windows 95/98 may show scroll to USB PORT SETUP. Press the ENTER button to enter it.
Hypertrm .exe).
| 30 | | 31 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
9. In order to saving the file to the PC, on the Hyper Terminal screen, click the [Transfer]
NOTE!!!
쮡 [Capture Text] 쮡 [Stop]. Then the “END OF FILE” is displayed on the PC monitor
The communication parameters of the computer should be the same as those of the and the saving is completed.
analyzer.
4-6-2. How to upload the Satellite file list and Project file list from
4. In HyperTerminal, click on [File] 쮡 쮡 쮡
[Properties] [Setting] [ASCII]. the Analyzer to the PC
Adjust the [line delay] upon your PC telephone operation environment.
Click the [Confirm]. 1. In HyperTerminal, click on [Transfer] 쮡 [Capture Text] . A dialog box appears where
you can enter a filename and choose the folder where it will be saved. HyperTerminal
uses ‘CAPTURE.TXT’ as a default filename - The user can change it to other file name.
Press ‘Start’ when the adjustment is finished.
4-6-1. How to saving the measured Data and uploading the file to the PC
2. If you want to upload the satellite file list to the PC, select the [UPLOAD SAT LIST] on
1. On the Main menu, select the menu [SCAN & DATA LOGGER]
the menu of [USB PORT SETUP] of the analyzer. Select the [UPLOAD PROJECT] if you
want to upload the project file list.
2. On the [SCAN LIST], select the list which is to be saved.
On the [TARGET LNB], select the LNB which is to be saved.
3. The transmission is started and the LED of remote mode on the analyzer is blinking.
5. In order to saving the file to the PC, on the Hyper Terminal screen, click the [Transfer]
4.After the finishing the data saving, [END OF SCANNING] is shown and the beep sounds. As
same method, maximum 99pcs can be saved.
쮡 [Capture Text] 쮡 [Stop]. Then the “END OF LIST” “END OF PROJECT” are displayed
respectively on the PC monitor, and the saving is completed.
| 32 | | 33 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
NOTE!!!
The file list which is shown on the Hyper Terminal screen is just shown as the
transmission screen. Thus it is mandatory to take a list saving as stipulated as above.
5 Specifications
4-6-3. How to download the Satellite file list / LNB Configuration file
list / SW(Switch) Configuration file list from the PC to the
Analyzer
1) DIGITAL SAT MEASUREMENT
1. In HyperTerminal, click on [Transfer (T)] 쮡
[Transfer Text file (T)] . A dialog box • Frequency Range : 950MHz~2,150MHz
appears where you can enter a filename and choose the folder where it will be saved. • Frequency Resolution : 0.1MHz
Select the file that you want to save and click “Open”. • Level Measurement Range : 20 ㏈㎶ ㏈㎶
(-40 )~110 ㏈㎶(+50㏈㎶)
• Level Measurement Resolution : 0.1㏈
2. Select [USB PORT SETUP] and [DOWNLOAD LIST] in a sequence on the analyzer menu. • Level Measurement Bandwidth : 3~20MHz or AUTO
± ㏈
• Level Measurement Accuracy : 2.0 (5~50°C)
3. The transmission is started and the LED of remote mode on the analyzer is blinking. • LOCK Range : 25 ㏈㎶ ㏈㎶ ㏈㎶ ㏈㎶)
(-35 ) ~ 110 (+50
• DVB-S QPSK
-. Symbol Rate : 1~45Msps
-. FEC : 1/2, 2/3, 3/4, 5/6, 6/7, 7/8
• DVB-S2
1) QPSK
-. Symbol Rate : 1~36Msps
-. FEC : 1/4, 1/3, 2/5, 3/5, 1/2, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10
2) 8PSK
-. Symbol Rate : 1-30Msps
-. FEC: 3/5, 2/3, 3/4, 5/6, 8/9, 9/10
• DSS QPSK
-. Symbol Rate : 20Msps
-. FEC : 3/4, 5/6, 6/7
• SNR Range
-. QPSK : 2~16 ㏈, 8PSK : 3~20㏈
• BER Range : PRE-BER : 2XE-2~2XE-8 / POST-BER : 2XE-4~2XE-9
• Spectrum Inversion : Auto
• Scan Mode
-. List Scan in programmed lists : Max. 84 TP
-. Blind Scan(DVB / DSS / DVB-S2):Scanning for SR, FEC, Frequency, Level, SNR
• I/Q Constellation Diagram : QPSK, 8PSK
| 34 | | 35 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
| 36 | | 37 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2
Warranty Card
6 Warranty
Thanks for taking the time to fill out your warranty card. Please fill in the
requested information below and your new product will be properly registered.
We warrant all products against defects in material and workmanship under normal use and
provides for one year from the date of purchase by the first buyer. Please note that this does
not include consumable items such as batteries. Warranty Card
Our liability is limited to the cost of repair and/or replacement of the product under warranty.
■Product : Digital Satellite Meter 1680S / 1680S2
In order to keep this warranty effective, the product must be handled and used as prescribed in
the operating manuals accompanying this warranty. ■Serial No. :
The warranty does not cover any damage caused by improper storage, improper installation,
■Date of Purchase(MM/DD/YY) : / /
unauthorized modification, accident, misuse, abuse, inadequate maintenance or negligence. It ■Buyer Name :
is also invalidated if unauthorized person carry out any alterations or repair.
Address :
In the event that you should require service assistance, please contact the dealer from where
Phone Number :
the product was initially purchased.
■Dealer Name :
If this is not possible, for example if you moved home, please contact us. Please have your full
model number and serial number, date and place, purchase and a brief description of the Address :
fault/query ready when contacting our service team.
Phone Number :
If the product is outside the warranty period, you should contact the dealer for a chargeable ■Fault description:
repair.
If the product is covered by an extended warranty, you should contact the dealer from whom
this extended warranty was purchased(usually the same dealer from which the product was
originally purchased).
Telemann Corporation
D-612, Dawoo Techno-Park, 187-7
Dodang-Dong, Wonmi-Gu, Bucheon-Si,
Gyeounggi-Do, R.O. Korea
Tel : 82-32-678-8566
Fax : 82-32-678-8568
E-Mail : info@telemannco.com
www.telemannco.com
| 38 |