Table of Contents
1. Features 4

2. Safety Instructions 5

3. Preliminary remark 7

4. Operations 8

4-1. Analyzer Overview 8

4-2. Antenna Adjustment 10

4-3. Digital Signal Quality Confirmation 13

4-4. LNB Current Measurement 14

4-5. Menu Screen 14

4-5-1. SAT SIGNAL ANALYZER 15

4-5-2. DUAL SAT MEASUREMENT 15

4-5-3. SCAN & DATA LOGGER 16

4-5-4. SPECTRUM ANALYZER 19

4-5-5. QPSK CONSTELLATION 22

4-5-6. SYSTEM CONFIGURATION 22

4-5-6-1. SYSTEM SETUP 23

4-5-6-2. SATELLITE TP LIST 26


This document contains information proprietary to Telemann.
The information in this document is not to be used or duplicated 4-5-6-3. SATELLITE FILE LIST 27
in any manner without prior approval, in writing, of Telemann.
4-5-6-4. USB PORT SETUP 27
In addition, it can be modified without prior notice.
4-5-6-5. LNB CONFIGURATION 27

4-5-6-6. SW CONFIGURATION 28

4-5-6-7. DiSEqC COMMAND LIST 28

4-6. The up/downloading the file to the PC 29

4-6-1. How to saving the measured Data and uploading the file to the PC 32

4-6-2. How to upload the Satellite file list and


Project file list from the Analyzer to the PC 33

Telemann Corporation
4-6-3. How to download the Satellite file list / LNB / Configuration
D-612, Dawoo Techno-Park, 187-7 file list / SW(Switch) Configuration file list from the PC to the Analyzer 34
Dodang-Dong, Wonmi-Gu, Bucheon-Si,
Gyeounggi-Do, R.O. Korea 5. Specifications 35
Tel : 82-32-678-8566
Fax : 82-32-678-8568 6. Warranty 38
E-Mail : info@telemannco.com
www.telemannco.com Version 1.2 (2008. 08) Warranty Card
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

6) Easy upload/download new satellite file list from PC using USB port
The user can upload/download new satellite file list from PC and transmit it to the unit using
HyperTerminal program in window system. Max. 99 satellites information (Max 2,560 TP) files

1 Features can be saved into the Analyzer.

7) Data Logger with USB port


The 1680S/S2 analyzer has the function of upload/download the measured files (max. 99files)
and transmit the scanned file from analyzer to the PC using HyperTerminal program in window
system. The printing of the files saved at the PC is available.
1) Speedy and convenient measurement by Project name mode
Just by the one time setup of the Project name mode, very convenient measurement without 8) Max. Hold (Peak level detection)
the job of mode setting of LNB, SWITCH and others upon the satellite is activated speedy. It When the 1680S/S2 detects a peak level, with the mode of CODE & LEVEL with audible tone
assists the rapid measurement for installation and maintenance at the field. and OFF without sound.

2) I/Q Constellation Diagram 9) Easy Portable & lightweight Type


Constellation displays are useful because they provide an in-service, visual means of The weight is less than 650g including the rechargeable battery packs. 128 X 64 dot matrix LCD
determining signal quality. Based on recognizable patterns, it is possible to get an idea of what screen shows measurement data clearly through both graphical and numerical form.
kind of impairment may be degrading a channel. Especially, 8PSK transmits more symbols than
QPSK to send more data information. The distance between symbols of 8PSK is closer than
QPSK and 8PSK can be influenced by interference easier than QPSK accordingly.

3) Spectrum Analyzer Safety


2 Instructions
The 1680S/S2 enables you to see the different spectrum waveforms for each satellite and see
where problems are in the receiving satellites signal. This function is very useful for the field
The following contents are for the prevention of use’s damage and
technicians to install a satellite antenna very quickly and correctly. Spectrum span is adjustable
property loss. Read them thoroughly and use the analyzer rightly.
like 120MHz, 240MHz, 600MHz and Full. The response speed of 1680S/S2 is very fast. In
addition, you can measure a signal level for the selected frequency by one or dual markers as
well as the bandwidth between the selected frequencies.
This symbol is intended to alert users of possible dangers in operating this
analyzer.
4) MER, Pre-BER, Post-BER, SNR measurement
The important measurement factors to measure digital signal of satellite are MER (Modulation
General
Error Ratio), SNR (Signal to Noise Ratio),) and Pre-BER/Post-BER (Bit Error Rate). 1680S/S2
measures MER, SNR, Pre-BER & Post-BER for digital signal very fast. The Analyzer enables
• Don’t disassemble, repair and remodel the analyzer.
you to confirm the quality of digital signal after adjusting a satellite antenna.
쮡 When repair is needed, contact to the service center.
• After being fully aware of user manual, operate and install the analyzer.
5) Blind Scan for DVB-S, DSS, DVB-S2 & TP List Scan
• Observe the ranges of power supply and measurement according to the user manual.
User can scan for all saved satellites automatically. Also, even if user doesn’t know any
• The analyzer and accessories should be installed, operated and maintained only authorized
information on the incoming satellite signal, the Analyzer can do an automatic scan of that to
personnel. Faulty installation or service may result in an accident and make invalid warranty.
identify the frequency as well as symbol rate, polarity and etc.

| 4 | | 5 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

Circumstances
• Use the analyzer in the temperature range from 5 to 50 ℃. Preliminary
Installation
3 remark
• Don’t connect any cables which are not offered by manufacturer.
쮡 It may cause fatal damage to the analyzer. 1. Check out the packing status.
• Only use the chargeable batteries, adapter and USB cable provided by manufacturer. Using 쮡 In case of damaging the packing box, contact to the dealer or service center. Keep the
unauthorized accessories could avoid warranty. damaged packing box as it is so that we can figure out the point of problem correctly.

2. Open the box and check out its contents.


쮡 The standard accessories for 1680S/1680S2 are the portable bag including the unit,
Battery Charge shoulder strap, F type connector, adapter, DIN-USB cable and user manual.

3. Connect the adapter to the unit in order to charge/recharge the batteries.


• Don’t supply the power to the analyzer without setting the rechargeable battery pack. It may
쮡 1680S : Ni-MH rechargeable batteries(total 7.2V. 2100m. A size)
give a serious damage to inner circuit.
• For the model of 1680S, recharge the batteries after being discharged completely, not to
쮡 1680S2 : Li-PO rechargeable batteries(total 7.4V. 3800mA)
The basic Adapter : DC12V/500mA
shorten their life span.
• Before using adapter, check whether its power is united to the main power. Or the inner
circuit may be damaged.
• Use a car cigarette adapter with 0.75A fuse. The inner circuit may be damaged.
• Use a car charger adapter as 13.8V. Do not use the 24V DC of big truck.
• When you use a car cigarette adapter, get the car started before charging the batteries.
Very Important!
Otherwise, the batteries may not be fully recharged or the car may be discharged.

Cautions for battery charge


1) All Telemann analyzers can interrupt improper power supply in order to protect their inner circuits
from any possible damage.
Maintenance 쮡 Please turn the damaged analyzer to our A/S as the fuse should be replaced. In this case, repairing cost is
charged to buyer regardless of the warranty period.
• Unplug the unit from the wall outlet before cleaning. Don’t use liquid, wax and aerosol cleaner.
2) It is recommended to charge battery before turn off. Charging battery during operation is possible.
Use a dry cloth.
• Use a dry cloth in cleaning contacting parts. Don’t use a wet cloth.
쮡 In this case, we are not responsible for any damage that may happen.

3) For the 1680S, after discharging completely, it takes for more than 8 hours to fully recharge batteries.
쮡 The battery charging time is upon the battery status.

4) When the battery charge level becomes low and you hear the warning tone, you should recharge the
batteries. If the battery charge level becomes exceedingly low, the analyzer will automatically power off.

| 6 | | 7 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

4. Check out whether satellites and transponders are saved into the analyzer correctly.

5. Connect F type connector to the unit. ■ Bottom View


6. Connect the satellite coaxial cable between F type connector of the analyzer and the
output of LNB. Adapter port DIN-USB cable port
(Connecting to PC)

Operations ■ Keypad - Each button’s function


4 The analyzer has a 7-button keypad. By pressing designated button combinations, you can
access to all the button functions of a keypad

4-1. Analyzer Overview


The descriptions for each part and its function of 1680S/1680S2 enable users to understand
and operate the unit well.

■ Front View ■ Rear View


F-JJ connector

”F”-male base connector


Functions Buttons

1. To move the setting bar to


up/down/left/right (Arrow buttons)
128X64 dot Matrix LCD
(with backlight)

2. To change the parameter value

3. To select and save mode


(Enter button)
Keypad
4. To change the measurement mode
(Finger button)

5. To turn power on or off


(Power button)

Battery Charge Remote Mode

| 8 | | 9 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

Move a dish until the position of satellite is found. When the analyzer detects the
correct position of satellite, “SERCHAING” message is changed to “FOUND”. When
NOTE!!!
the display is changed to “FOUND”, keep moving a dish until “S” (Signal Level) and
“Q” (Signal Quality) are peaked to the maximum value. The analyzer beep the higher
audible tone closer to the maximum level and lower beep sound more estrange from
1) LCD backlight On/Off the max level.
To turn on the LCD backlight, press enter button more than 2seconds. To turn off the LCD backlight, Signal tone is generated from over 40dB ㎶of the current level, but if the current level
same method.
is lower than 20dB lower than the peak level, signal tone will not be generated.
2) LCD Contrast Level Control
To adjust the contrast level of the analyzer, turn the analyzer off. Press the power button first and press When the max level is reached, fix the dish and LNB.
the enter button. Release the power button, then the mode of CONTRAST ADJUSTMENT is displayed. (If “S” value is only displayed not show “Q”, different satellite is found)
By pressing the Left/Right button to adjust the LCD contrast level and press enter button for saving.
Or, you can adjust the LCD CONTRAST level on the mode of SYSTEM SETUP.

3) When you want to initialize the analyzer To set the parameters of satellite, transponder frequency, polarity / signal band, transponder
Turn the analyzer off. Press the power button with pressing the left arrow button. Release the power name / channel name, level unit, Project name (local frequency and LNB current adjustment),
button. Then the mode of DEFAULT OPTION SETUP is displayed. By pressing the enter button, you can use the setting bar pressing the buttons (up/down/left/right/next/enter).
make the analyzer to the factory default settings.

Satellite name Longitude

Polarity/Signal Band
4-2. Antenna Adjustment Transponder Frequency Transponder
number/Channel Name
Press and hold the power button. The first screen shows
model name, battery charge percentage.
Level Unit
22KHz pulse/DiSEqC
Project name Battery balance

As you release pressing the power button, the first screen is


changed to the second screen automatically. The satellite [ Satellite name]
name, longitude, transponder frequency, polarity / signal To change the Satellite, move the bar on the Satellite mode using the arrow buttons. Press
band, transponder number(or channel name), signal the enter button when the bar is on the mode, the underline is displayed. Use the up/down
level(dB or %), signal quality (SNR, dB or %), project name, buttons, the Satellite is changed. The longitude is automatically followed upon the Satellite.
22KHz pulse/DiSEqC, battery balance are displayed. [Longitude]
The longitude of the current satellite is displayed according to the satellite.
To change the setting value, press up or down button to
[Polarity / Signal Band]
move the setting bar to your desired setting and then, enter
The polarity and band of V/Hi, H/Hi, V/Lo, H/Lo are displayed and can be selected using the
button to select it. When the selected setting is blinking,
enter button first and the arrow buttons.
press up or down (arrow) button to change its parameter.
And press the enter button again to terminate the changing.

| 10 | | 11 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

[ Transponder Frequency] How to set DiSEqC commands


a) To change the value from GHz to MHz, press the enter button twice and vice-versa.
b) When the unit of transponder frequency is displayed as MHz, Intermediate Move the bar to the DiSEqC mode of the 22KHz or Dis and press the enter button.
Frequency(IF), which is subtracted the current local frequency from the transponder
frequency will be displayed. The range is adjusted from 950 to 2,150MHz.
c) You can change the transponder frequency and measure it freely. In this case, channel
name(or transponder number) will be displayed as “CHANGED”.
[Transponder Number / Channel Name]
Press the enter button twice, and channel name will be changed to transponder number,
Select the DiSEqC switch using the up/down buttons and
and vice versa. Transponder frequency will be changed automatically according to the press the enter button.
change of channel name (or transponder number).
[Project name 쮠쮡Local Frequency]
LNB local frequency is changeable. After placing the setting bar on the Project name, press
the enter button, then the LO [Local Frequency] is displayed. Press the enter button and
select the Local Frequency using the up/down arrow buttons. The most popular Local Move the antenna position by using the
frequencies are programmed and can be selected and saved by pressing the enter button. up/down/left/right buttons as follows.
To change the mode from the Local Frequency to the Project name, press the enter button
twice after positioning the bar on the Local Frequency. A (Drive E. fast) ; To move the antenna to the East quickly.
[Level Unit]
Press the enter button, and RF level value is displayed as dB or %(linear mode). B (Drive W. fast) ; To move the antenna to the West quickly.

[22KHz pulse / DiSEqC]


Low band (22KHz OFF) or High band (22KHz ON) is selectable C (Fine tune east) ; To move the antenna to the East slowly.

NOTE!!!
D (Fine tune west) ; To move the antenna to the West slowly.

LNB switch control : 22KHz Pulse or DiSEqC


F 。
(Goto ref point/i.g.: Goto 0 ) ; To move the antenna back to the
LNB signal output can be controlled by 22KHz pulse or DiSEqC. basic adjusted position.
DiSEqC is an open standard that stands for digital satellite equipment control. DiSEqC system
has been designed primarily to meet the problem of two-satellite, two-band systems easily. It
has dedicated outputs to select polarity, satellite position and frequency band. The option output 4-3. Digital Signal Quality Confirmation
can be used along with the satellite position output to select up to 4 LNBs on a multi-feed
system.
To measure the important factors of checking the digital signal of satellite, press the finger
A powerful rotator (motor) is used to move dish. The principal of a motorized system is that the
button on the Antenna Adjustment mode [4-2]. Then the value of SNR (Signal to Noise
dish moves from east to west to track the satellite positions. It utilizes a data stream passed up
the LNB co-axial cable is needed for installation. Ratio) or MER (Modulation Error Ratio), pBER (Pre-Bit Error Rate), aBER (After-Bit Error
Rate) are shown.
1680S/1680S2 enable you to move a satellite rotator control a DiSEqC antenna rotator and
adjust satellite antenna.
The analyzer has the function of the auto detection for MER, SNR and BER very fast. This
function enables you to confirm the quality of digital signal after adjusting a satellite antenna.

| 12 | | 13 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

The higher Q value shows the better signal. 4-5. Menu Screen

After checking the actual LNB current, press the finger button, and the Menu Screen shows
six menus. In order to select the desired menu, press the up/down/left /right button and
press the enter button to access the selected menu.
In any menu, you can access to the menu screen directly by pressing the finger button more
• MER : the higher value the better signal. Over 15dB is excellent signaling condition and than 2seconds.
minimum valid signal is 12dB.
• SNR: the higher value the better signal. Over 10dB is good signaling condition and
minimum valid signal is 8dB.
• Pre-BER: Before BER. Bit error rate before correcting by FEC.
• Post-BER: After BER. Bit error rate after correcting by FEC.
• BER value is marked as x.xE-x and lesser error bit of the total transmitting bit means better
signal. I.g, BER 4.0E-5 means 4X10(-5), 4bits are error on the 100,000bit. The Pre-BER
[1680S menu screen] [1680S2 menu screen]
should be more than x.xE-4.

NOTE!!!
NOTE!!!

① The symbol rate of FEC is shown at the bottom side of screen.


The Constellation mode of 8PSK and QPSK automatically changed in 1680S2.

② If you want to change the transponder frequency, you can changed


symbol rate freely as well. Symbol rate will be detected automatically and
displayed. For example, 21.xxx means that the unit is detecting the symbol rate
from 21.000 to 21.999Msps. 4-5-1. SAT SIGNAL ANALYZER
By pressing the finger button or the enter button, the below modes will be
shown. Please refer to the above explained guide on the [4-2, 4-3, 4-4]
4-4. LNB Current Measurement

To measure the actual LNB power and C/N (Carrier to


Noise Ratio), press the figure button on the Digital
Signal Quality confirmation mode [4-3], then the below
display is shown.

In case of LNB power is over than 450mA by LNB defect Satellite Antenna Adjustment Digital Signal Quality LNB Current Measurement
Confirmation
or cable short circuit, the analyzer display OVER LOAD
with beep sound. Then, remove the cable and check the cable and LNB condition. 4-5-2. DUAL SAT MEASUREMENT
By pressing the finger button or the enter button on the Main menu, the
below mode is shown.

Two satellites can be measured at the same time as shown as the


following screen.

| 14 | | 15 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

3) BLIND SCAN FROM/TO


The Satellite name, Transponder number (or To set up the Frequency range for scaning, press the enter button. Then the black bar is moved to
Channel name), Frequency, Polarity/Signal band the right side from the whole line covering.
can be changed. The changing method is first By using the left/right arrow buttons, select the mode of ten digit and hundred digit. After
move the black bar to the designated mode by selecting the digit, change the frequency by pressing the up/down arrow buttons. The frequency
using the arrow buttons and secondly, after range from 950M to 2150M is selectable. And press the enter button for saving the value.
pressing the enter button, change the value by the
up/down buttons. After changing, press the enter 4) MIN.SYMBOL RATE / MAX. SYMBOL RATE
button for completion. To set up the Symbol rate range for scaning, press the enter button. Then the black bar is moved
By pressing the finger button, you can back to the Main menu. to the right side from the whole line covering.

By using the up/down/left/right arrow buttons, select the symbol rate for changing. The symbol
4-5-3. SCAN & DATA LOGGER rate range from 1M to 45M is selectable. And press the enter button for saving the value.
By pressing the finger button or the enter button on the Main menu, the
For a quick scan, the narrow setup of symbol rate is recommended.
below mode is shown.

You can scan all active transponders of the selected satellite which was saved in the 5) MIN. SCAN LEVEL
analyzer. And the review for the scanned transponders including the frequency, symbol To set up the minimum level for scaning, press the enter button.
rate, FEC, SNR and level is available. Then the black bar is moved to the right side from the whole line
covering.
To select the mode, press the up/down arrow buttons. After pressing the enter button, By using the up/down/left/right arrow buttons, select the level
select the value by using the arrow buttons, and press the enter button for saving. ㎶
number for changing. The range from 40 to 70dB by 5dB step or NONE is selectable. And press
To back to the Main menu, press the finger button. the enter button for saving the value.

1) SCAN LIST 6) START SCANING


To select the scan list, press the enter button. Then the black After finishing setup the above procedure of 1) ~5), the scanning is available.
bar is moved to the right side from the whole line covering. Press the enter button, the [SELECT SCAN LIST] mode is shown.
By using the up/down/left/right arrow buttons, select the TP
On the [START SCANNING] mode, by pressing the enter button, DATA/FILE NAME can be printed.
LIST or BLIND. And press the enter button for saving the value.
To move, press the left/right arrow buttons. To select A~Z, 1~9 in sequence, press the up/down
buttons. To delete the selected value, press the button until the black bar after number 9 is shown
NOTE!!!
and move the bar to left/right. After input the value of DATA, FILE NAME, press the enter button.
What is the Blind Scan? Then the BLIND SCAN is automatically started. And press the enter button for saving the value.
Even in the condition that you don’t know which satellite is being currently
received, you can simply get all information for the satellite such as frequency, In case of fail the SCAN, [EMPTY SCAN LIST] is shown. Then press the finger button to back to
symbol rate, level, SNR, FEC using the blind scan function.
the higher mode.

2) TARGET LNB
To select the LNB, press the enter button. Then the black bar is moved to the right side from the 7) REVIEW SCAN LIST
whole line covering. Press the enter button, the [SELECT SCAN LIST] mode is shown.
By using the up/down/left/right arrow buttons, select the mode of 1st / 2nd / ALL. On the ALL mode, In case of no scanned list, [EMPTY SCAN LIST] is shown. Then press the finger button to back to
press the arrow button one more, then the modes of 1st / 2nd is shown. And press the enter button the higher mode.
for saving the value.

| 16 | | 17 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

8) START DATA LOGGER 4-5-4. SPECTRUM ANALYZER


To put the DATA, FILE NAME, TIME (year, month, date, hour, This function enables you to check the frequency distribution curve and to
minute) in, press the enter button, the [START SCANNING] mode figure out which point has a problem on the receiving satellites signal.
is shown. By pressing the finger button or the enter button, the below mode is
The standard of PASS/FAIL used in the DATA LOGGER is displayed.
adjusted at the SYSTEM SETUP mode.
(A) (B) (C)
DATA/FILE NAME can be printed. To move, press the left/right arrow buttons. To select A~Z, 1~9
in sequence, press the up/down buttons. To delete the selected value, press the button until the
black bar after number 9 is shown and move the bar to left/right. After input the value of DATA,
FILE NAME, press the enter button. Then the TIME, DATE can be printed. By pressing the enter
button, DATA LOGGER mode is automatically shown.

In case of no SCAN file, [SIGNAL NOT FOUND] and [EMPTY SCAN LIST] is shown. Then press the Move a black bar to (A) or (B) or (C) position by using arrow buttons.
finger button to back to the higher mode.
(A) When a black bar is located on (A) position
9) REVIEW FILE a) Spectrum span adjustment
To watch the saved file, press the enter button. Then the [REVIEW FILE] is shown. By pressing the enter button, the underline is shown.
By pressing the finger button or the enter button, the mode is back to the higher mode.
The spectrum span adjustment is available by using the down arrow buttons.
10) UPLOAD ONE FILE FULL 쮡 600M 쮡 240M 쮡 120M
By pressing the up arrow button, the below span is available.
쮡 쮡 쮡
To select one file to upload to a PC, press the enter button. The [UPLOAD FILE] is shown.
By pressing the finger button or the enter button, the mode is back to the higher mode. 120M 240M 600M FULL
Press the enter button, the selected span is saved.
11) UPLOAD ALL FILE
To upload all files to PC at one time, press the enter button. The [UPLOAD ALL FILE] is shown. b) fast Spectrum sweep mode
When the “ Press ? Key to confirm” is displayed, press the enter button. Then all the file is Press the enter button twice quickly, the below spectrum screen is shown.
uploaded to the PC. The fast spectrum sweep mode helps the install an antenna with the quick feedback upon the
antenna positioning. (sweep speed: 300ms)

NOTE!!! Press the enter button, the selected span is saved.

For the more details, refer to the [4-6 The up/downloading the file to a PC] On the standard level setup mode, by pressing the left/right
arrow buttons, the screen display unit is changed to
12) DELETE ONE FILE 5dB/2dB.
To select and delete one file, press the enter button. The [DELETE FILE] is shown. By pressing the
enter button, the file is deleted. (B) When a black bar is located on (B) position
After pressing the enter button, the underline is shown, by using the up/down buttons, the standard level
13) DELETE ALL FILE : ㎶
value is changed. (Level range; 15~110dB )
To delete all files at one time, press the enter button. The [DELETE ALL FILE] is shown. When the Press the enter button, the adjusted level value is saved.
“Press ? Key to confirm” is displayed, press the enter button. Then all the file is deleted.

| 18 | | 19 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

C) When a black bar is located on (C) position By changing the span at the mode marked single cursor or double cursor, the Local frequency is
The following modes (i~ vii) are changed by pressing the up/down buttons. became the center of cursors location or between two cursors.

i) V/LO mode (To setup the Spectrum group by switching LNB switch)
v) A B : A TO B = xxx.xMHz (Frequency band between A and B marker)
After pressing the enter button, the underline is shown. By
At the (B marker and its signal level) mode, (no pressing the enter
using the up/down buttons, the spectrums waveform by LNB
button), press the up arrow button, the below picture mode is
switching such as V/LO, H/LO, H/HI, V/HI.
displayed. Press the enter button, the underline is shown.
By pressing the enter button, the setup is completed. It is shown the Frequency distance between A marker and B
The channels spectrum waveform contained in the adjusted marker.
group is shown. It is displayed as A TO B = xxx.x MHz.

ii) (Single Marker) Pressing the left/light button, A cursor vertical line is moved left/light. By pressing the up/down
At the right below mode (V/LO), (no pressing the enter button), button, B cursor vertical line is moved left/light.
press the up arrow button, the Single Marker mode is displayed. By pressing the enter button, the setup is completed.
Press the enter button, the underline is shown. By pressing the
up/down/left/right buttons, the correspondence level is shown vi) or (Spectrum Sweep)
as the signal marker (vertical line) is moving between left and At the (Frequency band between A and B marker) mode, (no
right. pressing the enter button), press the up arrow button, the below
By pressing the enter button, the setup is completed. picture mode is displayed. Press the enter button, the underline
is shown.
iii) A B : A = xxxx.x:xx.xdB (A marker and its signal level)
The peak level and its frequency are displayed as PEAK
쮡 쮠
At the Single Marker mode, (no pressing the enter button), press
the up arrow button, the below picture mode is displayed. Press xxxx.x:xx.xdB means spectrum sweeps from the left to the right and means spectrum
the enter button, the underline is shown. sweeps from the right to the left.
There is display of frequency and signal level as A. Pressing the up/down/left/light button, the direction of spectrum sweep is changed.
Pressing the left/light button, A cursor vertical line is moved
By pressing the enter button, the setup is completed.
left/light. By pressing the up/down button, B cursor vertical line
is moved left/light.
vii) (Rotator Control)
By pressing the enter button, the setup is completed.
At the (Spectrum Sweep) mode, (no pressing the enter button),
press the up arrow button, the below picture mode is displayed.
iv) A B : B=xxxx.x:xx.xdB(B marker and its signal level)
Press the enter button, the underline is shown.
At the (A marker and its signal level) mode, (no pressing the
In spectrum mode, you can control a rotator to the
enter button), press the up arrow button, the below picture
East/West/original position.
mode is displayed. Press the enter button, the underline is
shown. By pressing left/light button, the rotator is moved to East/West slowly. By pressing up/down
There is display of frequency and signal level as B. button, the rotator is moved to East/West quickly. By pressing the finger button, the rotator is
Pressing the left/light button, A cursor vertical line is moved left/light. By pressing the up/down back to the original position.
button, B cursor vertical line is moved left/light.
By pressing the enter button, the setup is completed.
By pressing the enter button, the setup is completed.

| 20 | | 21 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

4-5-5. QPSK CONSTELLATION 4-5-6-1) SYSTEM SETUP


The constellation display is the digital equivalent of a vectorscope display, showing in- Press the enter button on the [SYSTEM SETUP] mode, the below sub-menu are
phase (I) and quadrature (Q) components of the QAM signal. A symbol is the smallest displayed.
piece of information transmitted in a given modulation system. The constellation diagram
makes detailed diagnosis of digital signals simple. ⓐ PROJ
By pressing the enter button, it shows the project list.
Constellation displays are useful because they provide an in-service, visual means of
The user can select the desired satellite which is preprogrammed in the analyzer by moving the
determining signal quality. Based on recognizable patterns, it is possible to get an idea of
black bar as pressing the up/down button and save by pressing enter button.
what kind of impairment may be degrading a channel.
If the user want to change the project name, press the enter button twice quickly, then the name
can be changed by using the up/down and light/left buttons. Press the enter button for saving.

The LNB and SWITCH values are set up according to the


satellites, without the adjustment of satellite, LNB, DISEQC,
the measurement is simply activated.
The maximum 56pcs of project are programmed.

Specially DVB-S2 (HD) has the more symbol (8PSK) than SD level QPSK and it has more
interference influence. In this case, this mode shows the clue of the matter for finding
ⓑ LNB
By pressing the enter button, the programmed LNB lists are
correct point.
displayed. The user can select the desired LNB by using the
up/down button. Press the enter button for saving. The
maximum 70 LNBs are available.
4-5-6. SYSTEM CONFIGURATION
Press the enter button on the [SYSTEM CONFIGURATION] mode, the
below sub-menu are displayed.
ⓒ SW
It shows the programmed switch list by pressing the enter
button. Select the desired switch using the up/down buttons
and press the enter button for saving.
[MEMU]
The maximum 30 SWs are available.
4-5-6-1) SYSTEM SETUP
4-5-6-2) SATELLITE TP LIST
4-5-6-3) SATELLITE FILE LIST
4-5-6-4) USB PORT SETUP NOTE!!!
4-5-6-5) LNB CONFIGURATION
Please refer to the instruction of how to make update the project file list and on the
4-5-6-6) SW CONFIGURATION mode of [4-6. The up/downloading the file to a PC]
4-5-6-7) DiSEqC COMMAND LIST Please contact to the service center if there is required of adding the new file than the
programmed LNB and SWITCH in the analyzer.

| 22 | | 23 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

ⓓ LNB SETUP TIME ⓚ LNB EDITABLE


This mode is needed when you use a dual or universal LNB or DiSEqC switch in the dual LNB Press the enter button and select the YES/NO for edition on the SATELLITE TP LIST or
measurement mode or Scan measurement mode. SATELLITE FILE LIST by up/down/left/right buttons. The Default is set as No due to protect the
The analyzer’s default setup time is 200ms. However, when the actual response time is slower DATA loss by mistake.
than 200ms, the meter may not work correctly. In this case, please adjust the delay of setup
time properly. NOTE!!!
By pressing the enter button, 200/600/1000/1400ms can be selected by the up/down buttons.
Please refer to the manual [4-5-6-2, 4-5-6-3]

ⓔ LEVEL UNIT
After pressing the enter button and using the up/down/left/right buttons, Level unit is

selectable among dB , dBm or dBmV. (Default: dB ). ㎶ ⓛ LCD CONTRAST
By pressing the enter button, the value is saved. Press the enter button and adjust the LCD contrast level [1~9]
by using the up/down/left/right buttons. (Default: 7)
ⓕ MEASURE B/W-MHz
After pressing the enter button and select the digital level ⓜ BEEP SOUND
measurement bandwidth by using the left/right buttons. The Press the enter button and select the signal sound by using the up/down/left/right buttons.
bandwidth AUTO/3.0~26.0MHz are selectable. In case of -. CODE: If the searching Satellite, FEC and SR are correctly found, the analyzer sounds a high
AUTO, the analyzer measures the digital average power tone.
automatically upon the signal bandwidth. (Default: 3MHz). -. LEVEL: If the searching satellite is found, the analyzer sounds a tone. The responding speed
By pressing the enter button, the value is saved. is faster than the CODE mode.
-. OFF: No sound makes even the search is completed.
ⓖ CABLE-LOSS The default is CODE.
Cable Loss feature is to automatically compensate the measuring errors occurred when the
measuring cable has some loss or when you do measuring by connecting an impedance ⓝ BER RANGE
matching device to the input terminal. Press the enter button and select BER measure range [1.0E-6
Press the enter button and select the number by using left/right buttons. or 1.0E-8] by using the up/down/left/right buttons. 1.0E-6 is
The +0.0~+12.0 in 1GHz and 2 GHz can be selected. recommended for a quick measurement.

ⓗ LEVEL(%) REF ⓞ LEVEL LIMIT


Press the enter button and adjust the level value 60dB ㎶~90dB㎶ by up/down/left/right Press the enter button and select the reference level for PASS/FAIL in Data Logger by using
buttons. the up/down/left/right buttons. The range is 50~80dB ㎶, 1dB step or NONE. (Default:
The RF level reference as 100% is adjusted. (Default: 80dB㎶) 77dBuV)

ⓘ SIG. QUALITY ⓟ QUALITY LIMIT


Press the enter button and select SNR/MER by up/down/left/right buttons. (Default: MER) Press the enter button and adjust the digital quality reference [5~19dB or NONE ] for

PASS/FAIL according to the above mode [ SIG. QUALITY] in Data Logger by using the
ⓙ AUTO TIMEOUT up/down/left/right buttons.
Press the enter button and make turn off the analyzer automatically when it has remained
inactive for a certain period of time [5/10/30 minutes or CONTI] to save battery life. (Default:
5Minutes)

| 24 | | 25 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

ⓠ PRE-BER LIMIT 4-5-6-3) SATELLITE FILE LIST


Press the enter button and adjust the Pre-BER reference [1.0E-2~6] limit value for PASS/FAIL in To check all satellites which are saved in the analyzer.
Data Logger. Press the left/right buttons to select the number and set the value by the up/down
buttons.(Default: 1.5E-4) 1) To make the skip mode of selected satellite, press the
enter button after moving the black bar on the SKP
ⓡ COMPANY NAME column.
Press the enter button and put-in and save the company name. Press the left/right buttons to
move the cursor and select the alphabet or number value by the up/down buttons. Maximum 16
letters are available. Press the enter button to save the value. NOTE!!!

ⓢ USER NAME To mark the S, the mode of LNB EDITABLE should be saved as YES on the SYSTEM

SETUP mode. Please refer to the mode of “ LNB EDITABLE” on the 4-5-6-1)
Press the enter button and put-in and save the user name. Press the left/right buttons to move SYSTEM SETUP.
the cursor and select the alphabet or number value by the up/down buttons. Maximum 16
letters are available. Press the enter button to save the value. 2) Then the satellite marked S will be ignored on the measurement or saving mode.
On the Default of USER NAME, the overwriting is available. Press the finger button to back to the superior menu.

4-5-6-2) SATELLITE TP LIST 4-5-6-4) USB PORT SETUP


To check the transponder number, transponder frequency, polarity, channel name, To upload/download the preprogrammed satellite file list
polarity, symbol rate, FEC for all satellites which are saved in the analyzer. with the computer using USB cable, it is required to
match the communication parameters such as BAUD
1) Move the black bar on the satellite name, press the
RATE, DATA BIT, PARITY BIT, and STOP BIT for both the
enter button. The mode is changed to “Select SAT”.
analyzer and the computer (PC or Laptop).
Use the up/down/left/right buttons to change a
satellite. NOTE!!!

2) To check the symbol rate and FEC, press the right arrow button. For more details, please refer to the following manual [The up/ downloading the file
to the PC].
3) To make the skip mode of selected frequency, press the enter button after moving the
black bar on the SKP column. Press the finger button to back to the superior menu.

NOTE!!! 4-5-6-5) LNB CONFIGURATION


Press the enter button to go to the sub-menu.


To mark the S, the mode of LNB EDITABLE should be saved as YES on the SYSTEM Move the bar to the NAME mode and press the enter
SETUP mode. Please refer to the mode of [“ LNB EDITABLE” on the 4-5-6-1)
button, then the [SELECT LNB TYPE] mode is shown.
SYSTEM SETUP].

4) After the above process, the frequency marked S will be ignored on the measurement ① NAME : To select the desired LNB by pressing the enter button.
or saving mode. ② SW TYPE : To select the desired switch type by pressing the enter button.
Press the finger button to back to the superior menu. ③ LNB CONTROL : It shows the LNB control signal.
④ POLARITY : It shows the sort of LNB signal (RHCP/LHCP, Vert/Hori, Non-Pola)
| 26 | | 27 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

NOTE!!!
4-6. The up/ downloading the file to the PC
For the mode of [LNB CONTROL] and [POLARITY], manual change is not available as
it may commit the measurement error.
[Step 1 : Software Requirements]
To upload the Satellite file list or the measurement data files which was saved in the analyzer
Press the enter button to go to the sub-menu.
to the PC (Personal Computer), or update the files such as satellite list, LNB configure file or
Press the finger button to back to the superior menu. SW (Switch) configure file in the PC and download it to the analyzer, the below stipulated
software are need
① CP2102 USB to UART Bridge Controller driver
4-5-6-6) SW CONFIGURATION
To select the setup menus and change all related parameters.
② Hyper Terminal Software.

Please refer to the follow guide for CP2102 USB to UART Bridge Controller Driver and Hyper
Press the enter button to go to the sub-menu.
Terminal Software.
Move the bar to the NAME mode and press the enter
button, then the [SELECT SW TYPE] mode is shown.
[Step 2: Connect DIN-USB cable between the analyzer and the PC]
The DIN-USB cable is presented with the analyzer.

① NAME : Selectable the desired switch type. Please take the following procedure.
② CONTROL SIGNAL: It shows the Switch control signal. 1) Turn on the PC.
③ NUMBER OF PORT: It shows the Set switch port from 1 thru 8. 2) Connect the DIN-USB cable between the analyzer and the PC.
④ PORT 1~8 : It shows the config parameters for the selected switch port. 3) Turn on the Analyzer.
4) If the O/S (operation software) of the PC is the later version since then WINDOW2000/XP,
NOTE!!! the PC automatically searches the software of CP2102 USB to UART Bridge Controller and
installs it. Then please take the procedure from step 3.
For the mode of [CONTROL SIGNAL], [NUMBER OF PORT] and [PORT 1~8] manual
5) If the automatic installation is failed or the O/S of the PC is the prior version than
change is not available as it may commit the measurement error.
WINDOW98/SE, please install the driver manually as stipulated on the Step 2.
Press the finger button to back to the superior menu.
[Step 3: Install Driver]
1) Connect to the www.telemannco.com

4-5-6-7) DiSEqC COMMAND LIST
To check the DiSEqC commands and it can be changed for measurement condition. 2) Click the [DOWNLOAD] [Software].
3) Click the [CP2102 USB to UART Bridge Controller drivers for Windows]
Press the enter button to go to the sub-menu. 4) Download the suitable for your PC O/S system and install it.
In case of not working the DiSEqC switch, check whether the instruction word is rightly
adjusted. [Step 4: Checking for Comport]

1) Click the [My computer] [Properties (G)]
2) Click the [Device Manager] 쮡
Check the “+”symbol at the COM / LPT port.
3) If there is mode of [CP2102 USB to UART Bridge Controller], the installation is completed
well.

Press the finger button to back to the superior menu.

| 28 | | 29 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

[Step 5: Communication Configuration]


Before uploading/downloading the satellite list or uploading the stored file(s),
the communication parameters of your computer should be the same as those of the meter.

1. Connect the analyzer to the computer using USB cable.

2. Turn the computer on, and go to the HyperTerminal. Select [Start] 쮡 [Programs]쮡

[Accessories ] [Communications] 쮡 [HyperTerminal]. A large window will appear,
titled [New Connection] - [HyperTerminal]. A small window is titled Connection
Description and displays New Connection. Enter any appropriate name for the new
connection file and select any icon. File name can be descriptive, such as Test, low1,
TAB2, or ROOM3. Select OK. The HyperTerminal working window will now display the file
name in the title bar, followed by HyperTerminal. A small window will appear requesting
area code, phone number, etc. Skip all entry fields except Connect using. Select COM port
which is matched with your operating system. If you don’t know which COM port is
suitable for your system, click on [My Computer] 쮡 쮡
[Properties] 쮡
[Hardware]
[Device Manager] 쮡 [Ports]. You can see which port is for CP210x USB to UART Bridge
Controller.

Click OK and COM Port Properties window will open.

NOTE!!!

HyperTerminal Software 3. Turn the analyzer on by pressing the POWER button, and go to SYSTEM CONFIGURATION
If you are using Windows 98/98SE/ME/2000/XP, HyperTerminal software is one of
basic programs. To start HyperTerminal go to the [Start Menu] 쮡
[Programs] 쮡 mode by pressing the FINGER button more than 2sec. Use the UP and DOWN button to
[Accessories]쮡 [Communications] 쮡 [HyperTerminal] (Windows 95/98 may show scroll to USB PORT SETUP. Press the ENTER button to enter it.
Hypertrm .exe).

| 30 | | 31 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

5. In HyperTerminal, click on [Transfer] 쮡 [Capture Text] . A dialog box appears where


you can enter a filename and choose the folder where it will be saved. HyperTerminal
uses ‘CAPTURE.TXT’ as a default filename - The user can change it to other file name.
Press ‘Start’ when the adjustment is finished.
The required communication configuration is as follows;
6. If you want to upload the one file to the PC, select the [UPLOAD ONE FILE]. If you want
• Baud rate : The baud or bit rate The baud or bit rate establishes the speed of to upload the all files at a time, select the [UPLOAD ALL FILE].
communications between the analyzer and another device.
Baud values available are 9600, 19200, 38400, 57600. (19200 is recommended) 7. The transmission is started and the LED of remote mode on the analyzer is blinking.
• Data Bit: Data bits available are 7 and 8. (default: 8)
• Parity Bit: Parity bits available are NONE, ZERO, ODD, EVEN. (default: NONE) 8. On the Hyper Terminal screen, if the “END OF FILE”, “END OF TX” are shown, the
• Stop Bit: Stop bits available are 1 and 2. (default: 1) transmission is completed.

9. In order to saving the file to the PC, on the Hyper Terminal screen, click the [Transfer]
NOTE!!!
쮡 [Capture Text] 쮡 [Stop]. Then the “END OF FILE” is displayed on the PC monitor
The communication parameters of the computer should be the same as those of the and the saving is completed.
analyzer.

4-6-2. How to upload the Satellite file list and Project file list from
4. In HyperTerminal, click on [File] 쮡 쮡 쮡
[Properties] [Setting] [ASCII]. the Analyzer to the PC
Adjust the [line delay] upon your PC telephone operation environment.
Click the [Confirm]. 1. In HyperTerminal, click on [Transfer] 쮡 [Capture Text] . A dialog box appears where
you can enter a filename and choose the folder where it will be saved. HyperTerminal
uses ‘CAPTURE.TXT’ as a default filename - The user can change it to other file name.
Press ‘Start’ when the adjustment is finished.
4-6-1. How to saving the measured Data and uploading the file to the PC
2. If you want to upload the satellite file list to the PC, select the [UPLOAD SAT LIST] on
1. On the Main menu, select the menu [SCAN & DATA LOGGER]
the menu of [USB PORT SETUP] of the analyzer. Select the [UPLOAD PROJECT] if you
want to upload the project file list.
2. On the [SCAN LIST], select the list which is to be saved.
On the [TARGET LNB], select the LNB which is to be saved.
3. The transmission is started and the LED of remote mode on the analyzer is blinking.

3. Select the [START DATA LOGGER].


4. On the Hyper Terminal screen, if the “END OF LIST” is shown for the uploading of
The mode of File name, Date and Time is displayed
satellite file list and “END OF PROJECT” is displayed for the uploading of the project file
Input the file name, date and time, press the enter button.
list, the transmission is completed.
The Data saving is started.

5. In order to saving the file to the PC, on the Hyper Terminal screen, click the [Transfer]
4.After the finishing the data saving, [END OF SCANNING] is shown and the beep sounds. As
same method, maximum 99pcs can be saved.
쮡 [Capture Text] 쮡 [Stop]. Then the “END OF LIST” “END OF PROJECT” are displayed
respectively on the PC monitor, and the saving is completed.

| 32 | | 33 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

NOTE!!!

The file list which is shown on the Hyper Terminal screen is just shown as the
transmission screen. Thus it is mandatory to take a list saving as stipulated as above.

5 Specifications
4-6-3. How to download the Satellite file list / LNB Configuration file
list / SW(Switch) Configuration file list from the PC to the
Analyzer
1) DIGITAL SAT MEASUREMENT
1. In HyperTerminal, click on [Transfer (T)] 쮡
[Transfer Text file (T)] . A dialog box • Frequency Range : 950MHz~2,150MHz
appears where you can enter a filename and choose the folder where it will be saved. • Frequency Resolution : 0.1MHz
Select the file that you want to save and click “Open”. • Level Measurement Range : 20 ㏈㎶ ㏈㎶
(-40 )~110 ㏈㎶(+50㏈㎶)
• Level Measurement Resolution : 0.1㏈
2. Select [USB PORT SETUP] and [DOWNLOAD LIST] in a sequence on the analyzer menu. • Level Measurement Bandwidth : 3~20MHz or AUTO
± ㏈
• Level Measurement Accuracy : 2.0 (5~50°C)
3. The transmission is started and the LED of remote mode on the analyzer is blinking. • LOCK Range : 25 ㏈㎶ ㏈㎶ ㏈㎶ ㏈㎶)
(-35 ) ~ 110 (+50
• DVB-S QPSK
-. Symbol Rate : 1~45Msps
-. FEC : 1/2, 2/3, 3/4, 5/6, 6/7, 7/8
• DVB-S2
1) QPSK
-. Symbol Rate : 1~36Msps
-. FEC : 1/4, 1/3, 2/5, 3/5, 1/2, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10
2) 8PSK
-. Symbol Rate : 1-30Msps
-. FEC: 3/5, 2/3, 3/4, 5/6, 8/9, 9/10
• DSS QPSK
-. Symbol Rate : 20Msps
-. FEC : 3/4, 5/6, 6/7
• SNR Range
-. QPSK : 2~16 ㏈, 8PSK : 3~20㏈
• BER Range : PRE-BER : 2XE-2~2XE-8 / POST-BER : 2XE-4~2XE-9
• Spectrum Inversion : Auto
• Scan Mode
-. List Scan in programmed lists : Max. 84 TP
-. Blind Scan(DVB / DSS / DVB-S2):Scanning for SR, FEC, Frequency, Level, SNR
• I/Q Constellation Diagram : QPSK, 8PSK

| 34 | | 35 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

2) ANALOG SAT MEASUREMENT -. Output Current : Max. 450mA


• Frequency Range 950MHz~2,150MHz -. Auto Circuitry Protection(OVERLOAD): Max.500mA
• Frequency Resolution : 0.1MHz
• ㏈㎶ ㏈㎷
Level Measurement Range : 20 (-40 )~110 ㏈㎶(+50㏈㎷) 7) POWR SUPPLY
• ㏈
Level Measurement Resolution : 0.1 • Rechargeable Battery(Built-In) :
• Level Measurement Bandwidth : 3~20MHz or AUTO • • 1680S2: Li-Po 3800mA, 7.4V
• ± ㏈
Level Measurement Accuracy : 2.0 (5~50°C) • • 1680S: Ni-MH 2100mA, 7.2V
• ㏈ ㏈㎶ ㏈㎷ ㏈m
Level Units : ( , , ) or % • Battery Balance Status Indicator
• Continuous Operating Time in Full Charging (over 8hours)
3) SPECTRUM MODE • • 1680S2:
• Level Range : 40 ㏈㎶ ㏈㎶
~ 110 -. Approx. 3.5hr. (based on 100mA LNB supply)
• Measurement Range : 20 ㏈㎶ ㏈㎶~ 110 -. Approx. 7hr. (without LNB supply)
• Span : 120MHz, 240MHz, 600MHz ,FULL • • 1680S:
• Single / Dual Marker for Level or BW Measurement -. Approx. 2.5hr. (based on 100mA LNB supply)
• Peak Level Indication : Auto -. Approx. 5hr. (without LNB supply)
• Sweep Reverse -. Operating time depends on LNB current / LCD Backlight
• Sweep Rate : 900 ㎳ / 600 ㎳ / 300 ㎳ • Main Adapter : DC 12V/500mA
• Rotator Control in Spectrum Mode
8) Unit Dimension
4) USER CONFIG FOR LNB/SW/ROTATOR • Size : 94mm W X 47mm D X 190mm H
• Project File : Max. 56 • Weight : 650g(including battery pack)
• LNB Config File : Max. 70 • Graphic LCD : 128X64 dot matrix
• SW Config File : Max. 30
• SW Control : 22KHz, DiSEqC 1.0/1.1/1.2, Dish Legacy 9) Circumstance
• Sat. File : Max. 99(Max. 84TP per Sat File) • Usable Temperature : 5~50°C
• Rotator Control
• Adjustable LNB & DiSEqC with spectrum measurement 10) Standard Accessories
• User Manual in English
5) USB PORT • F connector
• Downloading / Uploading with PC : Config Files • Portable Bag with shoulder trap
• Downloading / Uploading / Printing with PC: Max. 99Logger Files • DIN-USB cable

6) OTHERS 11) Optional Accessories


• Beep Sound • Car Charger Cable
• Dual Measurement Mode
• Auto Timeout
• LCD Backlight NOTE!!!
• LNB Supply
±
-. Output Voltage( 1V) : 13V for V/R, 18V for H/L
Specification to be changed without a prior notice to customers.

| 36 | | 37 |
Digital Satellite SD & HD Broadcasting Signal Measuring Meter With Spectrum 1680S / 1680S2

Warranty Card
6 Warranty
Thanks for taking the time to fill out your warranty card. Please fill in the
requested information below and your new product will be properly registered.

We warrant all products against defects in material and workmanship under normal use and
provides for one year from the date of purchase by the first buyer. Please note that this does
not include consumable items such as batteries. Warranty Card
Our liability is limited to the cost of repair and/or replacement of the product under warranty.
■Product : Digital Satellite Meter 1680S / 1680S2
In order to keep this warranty effective, the product must be handled and used as prescribed in
the operating manuals accompanying this warranty. ■Serial No. :
The warranty does not cover any damage caused by improper storage, improper installation,
■Date of Purchase(MM/DD/YY) : / /

unauthorized modification, accident, misuse, abuse, inadequate maintenance or negligence. It ■Buyer Name :
is also invalidated if unauthorized person carry out any alterations or repair.
Address :
In the event that you should require service assistance, please contact the dealer from where
Phone Number :
the product was initially purchased.
■Dealer Name :
If this is not possible, for example if you moved home, please contact us. Please have your full
model number and serial number, date and place, purchase and a brief description of the Address :
fault/query ready when contacting our service team.
Phone Number :

If the product is outside the warranty period, you should contact the dealer for a chargeable ■Fault description:
repair.

If the product is covered by an extended warranty, you should contact the dealer from whom
this extended warranty was purchased(usually the same dealer from which the product was
originally purchased).
Telemann Corporation
D-612, Dawoo Techno-Park, 187-7
Dodang-Dong, Wonmi-Gu, Bucheon-Si,
Gyeounggi-Do, R.O. Korea
Tel : 82-32-678-8566
Fax : 82-32-678-8568
E-Mail : info@telemannco.com
www.telemannco.com

| 38 |

Das könnte Ihnen auch gefallen