FLUORESCENT MPI PROCESS GUIDE

1. Prepare Equipment
A-Series
Yokes
Y1 Yoke
Wet Method Particles
Magnaglo 14A
Particle Premixes
Magnaglo 20B
D-Series Y7 Yoke Magnaglo MG-410 Magnaglo 14A Redi-Bath
Clean the part or test MD-Series Y8 Yoke Magnaglo 14AM
Oil Vehicle
area with SKC-S M-Series Coils Magnaglo Carrier II Particle Aerosols
P-series L-10 Coil Magnaglo 14AM Aerosol
Water-Bath Additives
Magnaglo AX-52 Magnaglo 14A Aqua-Glo
Magnaglo WA-2B

2. Apply Particles Magnaglo ZAF-2

FIXED BENCH YOKE OR PRODS COIL OR CABLE WRAP


1. Mount the part to be tested 1. Position yoke or prods on the 1. Position coil or cables around the
2. Select current type and output part or test area part or test area
2. Select current type and output

3. Start the particle suspension flow


4. Switch on the magnetizing current
2. Switch on the magnetizing current
5. Apply suspension to all test surfaces 3. Switch on the magnetizing current
3. Apply the magnetic particles
6. Stop the particle suspension flow 4. Apply the magnetic particles
4. Switch off the current
7. Switch off the current 5. Switch off the current

3. Inspect Black Lights


EV-5000 LED
ZB-100F
Use an ultra-violet black light to inspect the part or test area for indications

4. Demagnetize
1. Switch on the magnetizing current
2. Put the part in the demagnetizing unit
3. Draw the part through the demagnetizing unit
4. Remove the part from the demagnetizing unit
5. Switch off the current
6. Check the part for residual magnetism

Magnaflux Tel: 1-847-657-5300 Fax: 1-847-657-5388


155 Harlem Ave Email: cs@magnaflux.com
Glenview, IL 60025, USA www.magnaflux.com
07/14