Sie sind auf Seite 1von 2

DL2/3A

Li/MNO2
Lithium/Manganese Dioxide Battery

Specifications

Classification: Lithium
Chemical System: Manganese Dioxide/Li/Organic Electrolyte
Designation: ANSI-5018LC, IEC-CR17345
φ 17.0 mm
16.0
Nominal Voltage: 3V
Typical Voltage: 3.2-3.3V
9.6 mm 1.0 mm
MAX MIN Nominal Internal 0.25 ohm @ 1 kHz
Impedance:
(+) Typical Weight: 17g
Typical Volume: 7.18 cm3 (cubic centimeters)

34.0 mm
Operating Temp: -20°C to 75°C (-4°F to 167°F
MAX Capacity: 1550 mAh
Self Discharge: 1.4% per year
(–)

Dimensions shown are IEC/ANSI standards

Duracell 2/3A Typical Performance

35mm Point &


Shoot Camera
1.2A, 3 sec on 7sec off,
to 1.7V @ 20°C

35mm SLR Photo


1.8A, 3 sec on 7sec off,
to 2.0V @ 20°C

ANSI Photo
0.9A, 3 sec on 27sec off,
to 1.55V @ 20°C
500 1000 1500 2000 2500

Pulse Cycles
Delivered Energy vs. Power Drain 1.8 Amp 3 sec on/ 7 sec off
@ Various Cutoff Voltage-Room Temperature @ Various Temperatures
2.7
2.2 -10°C
2
1.8 2.5 RT
4
Battery Voltage (V)

2.3
Energy (Wh)

2.1
2
1.9

1.7

1 1.5
0.2 0.5 1 2 4 0 100 200 300 400 500 600 700 800 900 1000
Power (W) Pulses

Information and contents in this data sheet are for reference purposes only. They do not constitute any warranty and representation
is subject to change without notice. For most current information and further details, please contact Duracell.

Page 1 of 2 DOCUMENT #: LM-A


DL2/3A

Li/MNO2
Lithium/Manganese Dioxide Battery

1.2 Amp, 3 sec on/ 7 sec off Continuous Discharge


@ Various Temperatures RT to 1.55 Volts
2.7 4
-10°C 10 mA
50 mA
-20°C
100 mA
2.5 RT 250 mA
500 mA
750 mA
3
Battery Voltage (V)

2.3 1000 mA

Voltage (V)
2.1

1.9

1.7

1.5 1
0 200 400 600 800 1000 1200 1400 1600 0.1 1 10 100 1000
Pulses Service (Hours)

0.9 Amp, 3 sec on/27 sec off


@ Various Temperatures
2.7
-10°C

-20°C
2.5
RT
Battery Voltage (V)

2.3

2.1

1.9

1.7

1.5
0 500 1000 1500 2000 2500
Pulses

BATTERIES
Berkshire Corporate Park
Bethel, CT 06801 U.S.A.
Telephone: Toll free 1.800.544.5454
Internet: www.duracell.com
*Delivered capacity is dependent on the applied load, intermittent usage, operating temperature and cut off voltage. Please
refer to the charts and discharge data for examples of energy/service life that the battery will provide for various conditions.

Information and contents in this data sheet are for reference purposes only. They do not constitute any warranty and representation
is subject to change without notice. For most current information and further details, please contact Duracell.

Page 2 of 2 DOCUMENT #: LM-A