Zones are configured within VSANs. The Logical tab displays the VSANs configured in the currently discovered fabric.
Note: zone information must always be identical for all the switches in the network fabric.
Configuring an Alias
Command Purpose
Step 2 switch(config)# fcalias name Alias_Sample vsan 3 Configures an alias name (Alias_Sample).
switch-config-fcalias#
Step 3 switch-config-fcalias# member pwwn xx:xx:xx:xx:xx:xx:xx:xx Configures alias members based on the specified port WWN type and value (pWWN xx:xx:xx:xx:xx:xx:xx:xx).
Command Purpose
switch# config t Enters configuration mode.
Step 1
switch(config)# zoneset name Zoneset1 vsan 3 Configures a zone set called Zoneset1.
Step 2 switch(config-zoneset)#
switch(config-zoneset)# member Zone1 Adds Zone1 as a member of the specified zone set (Zoneset1).
Step 3
switch(config-zoneset)# zone name Adds a zone (first-new-zone) to the specified zone set (Zoneset1).
Step 4 first-new-zone
switch(config-zoneset-zone)#
switch(config-zoneset-zone)# member fcid xxxxxxxxxx Adds a new member (FC ID xxxxxxxxxx) to the newly created zone (first-new-zone).
Step 5 switch(config-zoneset-zone)#
Changes to a zone set do not take effect to a full zone set until you activate it.
Command Purpose
switch# config t Enters configuration mode.
Step 1 switch(config)#
switch(config)# zoneset activate name Zoneset1 vsan 3 Activates the specified zone set.
storageteknologi.blogspot.com/2015/03/mds-series-switch-zoning-via-cli.html 1/3
3/26/2019 Piyush's Blog: MDS Series Switch Zoning via CLI
Step 2 switch(config)# no zoneset activate name Zoneset1 vsan 3 Deactivates the specified zone set
show zoneset vsan 1 Displays information for the configured zone set.
show zoneset vsan 2-3 Displays configured zone set information for a range of VSANs.