Beruflich Dokumente
Kultur Dokumente
ASTRA V1.2
V1.2
COLLECTIVE DOWN – 10 STOPS / COLLECTIVE FULL – 6 STOPS
WITH GRAPHICAL LCD
USER’S MANUAL
FOR S/W VERSION v2.00.F 1821
1 .GENERAL DESCRIPTION 2. TERMINAL DESCRIPTION 3. CONTENTS OF PAGES 4. VIEWING ERRORS AND
DISPLAYED ON LCD ERROR CODE DESCRIPTION
1.1 MAIN FEATURES 2.1 T 3.1 GRAPHICAL DISPLAY 4.1 HOW TO VIEW THE FAULTS
1.2 TECHNICAL DATA 2.2 INPUT TERMINALS 3.1.1 ELEVATOR STATUS 4.2 HOW TO ERASE THE FAULTS
2.3 OUTPUT TERMINALS 3.1.2 MOVING DIRECTION 4.3 FAULT CODE DESCRIPTION
2.3.1 OUTPUT TERMINALS FOR AC1 AND SPEED
SPEED, AC2 SPEED AND VVVF 3.1.3 DOOR STATUS
2.3.2 OUTPUT TERMINALS FOR 3.1.4 FLOOR NUMBER
HYDRAULIC STATUS
2.3.3 INDICATOR OUTPUT
TERMINALS REGISTRATION FUNCTION
2.3.4 INDICATOR OUTPUT
TERMINALS INSPECTION OPERATION
FOR INDICATOR=DECIMAL
2.4 CALLS TERMINALS
5. AUXILIARY 7. CASE
6. FIRMWARE 8. APPENDIX A
FUNCTIONS UPGRADE DIMENSION
MENU
5.1 MENU DESCRIPTION 6.1 INSTALLING THE ASTRA 7. CASE DIMENSION 8. APPENDIX A
FIRMWARE UPGRADE SOFTWARE
6.2 INSTALLING THE ASTRA USB
DRIVER
6.2.1 DRIVER SETUP FOR
WINDOWS VISTA/WIN7
6.2.2 DRIVER SETUP FOR
WINDOWS XP
6.3 FIRMWARE UPGRADE
PROCESS
6.4 INSTALLING THE SASPTOOL
FIRMWARE APPLICATION ON THE
MOBILE
6.5 FIRMWARE UPGRADE
PROCESS
1 .GENERAL DESCRIPTION
1. GENERAL DESCRIPION
1.1 MAIN FEATURES
Pla orm Microcontroller
Type AC 1 speed – AC 2 speed - VVVF – Hydraulic
Self diagnos c Error codes describing common faults related to periphery inputs
On-board display 8-characters by 2-lines LCD alphanumeric display is used for floor, error messages and menu
Push bu ons Three push bu ons used to access different parameter and the menu
Sha informa on End of sha in the up direc on
End of sha in the down direc on
Slow down and final stop in the up direction
Slow down and final stop in the down direc on
Car posi on is saved following a power failure
Indicator signal Gray Code or
Binary Code or
Enhanced Code (when using S.&A.S. scrolling display) or
7-Segment code or
Decimal
Number of stops 10 stops collec ve down – 6 stops collec ve selec ve
(when using Gray code or Binary code or Enhanced code or 7-segment)
9 stops collec ve down only when using 7-segment nega ve
9 stops collec ve down – 5 stops collec ve selec ve using Decimal code
5 stops Down collec ve with no mul plexing stages
Door type Swinging or automa c door or half automa c door
Door controls Input for re-open, photocell and door jam switch + input to bypass closing delay
Door status Parking with door opened or door closed
Floor Stop me Variable from 0 to 9.9 seconds
Car light Automa c switch off a er delay - 0 to 25.0 seconds
Inspec on mode For installa on and maintenance purposes using slow speed (bypasses all sha informa on)
PTC Input Motor PTC input halts li operation when motor overheats
Outputs Indicator and Call outputs are short circuit protected
Terminals All terminals are individually labeled according to func on to facilitate iden fica on
2. TERMINAL DESCRIPTION
2.1 TERMINAL LAYOUT
HIGH_SPD
LOW_SPD
CLSE CAM
SDPF_DN
17VAC A
17VAC B
INSP_DN
SFTY ON
SDFS_UP
INSP_EN
EOS_DN
INSP_UP
RE_OPN
EOS_UP
DN_DIR
CDOOR
UP_DIR
LS_EO
LS_EC
OPEN
C LGT
CDRV
LGHT
STAR
GND
CLSE
PUSH BUTTONS
+ HALL
- HALL
PTC A
PTC B
+ CAR
- CAR
D/d
A/a
B/b
↓/e
C/c
↑/f
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
g
↓
↑
5
2. TERMINAL DESCRIPTION
Although this is not an output, it is listed with the outputs for convenience.
For automatic or ½ automatic door only.
For swinging door.
For Gray or Binary or Enhanced code indicator. INDICATR = GRAY, GRAY 1, BINARY or ENHANCED.
For Seven segment code indicator. INDICATR = 7SEGMENT or 7SEGMNT- or 7SEGMNT1
For maximum 8 stops Lift.
6
2. TERMINAL DESCRIPTION
For Seven segment code indicator with basements: INDICATR =7SEGMNT- and SPARE OP not set to 7Sd –ve
For maximum 9 stops Lift.
7
3. CONTENTS OF PAGES
DISPLAYED ON LCD
8
3. CONTENTS OF PAGES
DISPLAYED ON LCD
NORMAL NORM
MOVING NORM
INSPECTION INSP
FAULT FLT
EVACUATION EVAC
HOMING HTRP
LANDING LAND
UP
DOWN
The moving Speed of the elevator will be represented by the scrolling speed of the direction arrows.
9
3. CONTENTS OF PAGES
DISPLAYED ON LCD
10
4. VIEWING FAULTS AND
FAULTS CODE DESCRIPTION
Not implemented
For swinging or ½ automatic door.
Waits for a call to resume operation.
For automatic door
When the cause of the fault is diagnosed and fixed, the elevator will automatically resume operation
To recover from this error, access ENTER MAINT. Refer to sections 5.1
When DZ magnetic switch is installed. Refer to section 5.1
11
5. AUXILIARY
FUNCTIONS
MENU
12
5. AUXILIARY
FUNCTIONS
MENU
AUT DOOR OPR. The Auto door is considered jammed a er this Auto/Half Dis, 1 to 99sec 20sec
delay Auto door
BASEMENT Sets the count of basements N/A 0 to 9 0
DOOR TYP Selects the type of the elevator door. Select ½ N/A SWINGING/ SWINGING
automa c door if there is an electric cam to AUTO /
lock the door in addi on to the automa c door ½ AUTO
drive.
PERM CLS When this feature is enabled, the door closing Automatic DISABLED/ ENABLED DISABLED
signal is permanently engaged during travel door
(required for specific types of door drives)
13
5. AUXILIARY
FUNCTIONS
MENU
What you see on DescripƟon and Comments Visibility Range Default Value
the display Condition
RE-OPEN IP Sets the logic of the re-opn input
N/A NO/NC NC
DOOR ZONE When enabled, SDFS DN input is re-assigned as N/A DIS/ENA DIS
DZ for automa c door only. DZ should be ac ve
on every floor stop to allow door opening
COLLECTV Selects between collec ve selective, down N/A FULL / DOWN / DOWN 5 / DOWN
collec ve , down 5 (no mul plexing stages: C0-- FULL 4
>C4: CC0-->CC4/C5-->C9: DC0-->DC4) and Full
4(no mul plexing stages: C0-->C3: CC0--
>CC3/C4-->C6: UC0--> UC2/ C7-->C9: DC1--
>DC3)
Sets the SLOW spare output func on when drive AC1SPEED GONG/½A CAM/FAN/
is set to “AC1SPEED” drive OPEN/CLOSE/LIGHT/
HI SPEED/UP O/P
DN O_P/Insp mod
SLOW O/P
FAN
14
5. AUXILIARY
FUNCTIONS
MENU
15
6. FIRMWARE
UPGRADE
6. FIRMWARE UPGRADE
6.1 INSTALLING THE ASTRA FIRMWARE UPGRADE SOFTWARE
In order to upgrade firmware on site, a CD will be provided by S. &A.S.Ltd & the below steps shall be
followed:
1. Run file “SAS_Patch.exe” located in “SAS_PTool\SAS_PTool” folder.
2. Setup the application located in “SAS _PTool\SAS_PTool \SAS_PTool_Setup” folder
3. SAS_PTool will appear in the programs list. Send it to Desktop as shortcut.
The “SAS DEV” device will appear in Other Devices, right-click it and choose Update Driver Software.
16
6. FIRMWARE
UPGRADE
17
6. FIRMWARE
UPGRADE
The Driver SETUP procedure will be done only once For Windows vista/Win7.
So, the driver of any new SAS Device connected to the PC USB port will be installed automatically.
The driver of the new SAS Device connected to the PC USB port will be installed automatically.
Click Open to choose the *.sas file that will be used to upgrade the firmware.
A Footnote will appear showing the file name, the software version and its date:
Click upgrade.
19
6. FIRMWARE
UPGRADE
Once the upgrade is complete, the footnote “Firmware upgraded successfully” will appear:
Then the SAS device firmware upgraded successfully, and the SAS device will automatically run the new
firmware.
20
6. FIRMWARE
UPGRADE
1. Search for the application “SASPTool” on Google play store and install it, or follow the link below:
https://play.google.com/store/search?q=SASPTool.
FIRMWARE UPGRADE PROCESS
2. Run “SAS_PTool” application from the mobile.
The below window appears showing all *.sas files already saved
21
6. FIRMWARE
UPGRADE
The following window will appear showing that a SAS Device is now connected:
A POPUP window will appear showing the file name, its description and its date:
7.. Click
Clil ck Y
Yes
es
22
6. FIRMWARE
UPGRADE
Once the download is completed, the message “Firmware downloaded successfully” will appear:
If you desire to delete any sas file from the mobile list, press and hold on the filename until a POPUP window
appears showing multiple choices and then click on Remove from list:
23
7. CASE
DIMENSION
7. CASE DIMENSION
8.9 mm
184.1 mm
P4 P6 P7
P8
4.0 mm
24
8. APPENDIX A
8. APPENDIX A
This appendix contains all wiring diagrams relevant to assembling the board in a panel.
25
1 2 3 4 5 6
R S T
(22V) (22V)
2 1
AC + PP
1
P
5 Amps
+
AC -
0 17 3300UF 50V 3300UF 50V
BRIDGE
A A
2
(60V) GND
L1 0 0 2 1
AC +
P3
L2 2 1 380 60
TRANSFORMER AC -
BRIDGE END OF TRAVEL UP
L3
0 Ch Cu
2 Amps BRAKE 4 3 6 5 END OF TRAVEL DOWN
17 CL Cd
R N SPEED GOVERNOR
4 3 6 5 (PARACHUTE)
SWINGING DOOR
AUTO. DOOR
10
Rd
1
21
21
21
P3 GND
Cd Cu Cl
22
22
22
P
A1
A1
A1
A1
Rlight Cu Cd Cl Ch
C GND C
10
GND
A2
A2
A2
A2
GND
CAR LIGHT UP DIRECTION DOWN DIRECTION SLOW SPEED HIGH SPEED
RELAY CONTACTOR CONTACTOR CONTACTOR CONTACTOR
Cl Ch
ASTRA V1.2 BOARD
2
6
U2
V2
W2
U1
V1
W1
S.&A.S. Ltd.
Jieh Chouf
Lebanon
MH support@sascontrollers.com
ASTRA WIRING DIAG: SUPPLY & OUTPUTS
D
ASYNCHRONOUS MOTOR DC Contactors D
Scale Sheet
-
1 of 9
1 2 3 4 5 6
26
1 2 3 4 5 6
A 5CM A
5CM
30CM SWINGING DOOR AUTOMATIC DOOR
15CM
P P3
OVERWEIGHT
P P P3
SWITCH
OVERWEIGHT
P
SWITCH
DOORJAM
21
21
SWITCH
B B
MICROSWITCH
Cc Co
CAR STEP
OFF=INSPECTION
22
22
5CM
ON=NORMAL
5CM 5CM
(REVISION)
PHOTOCELL
END OF OPENING
END OF CLOSING
3
3
FIRST STOP FIRST STOP FIRST STOP
CLOSE WITHOUT
A1
Cd Cu Cc
A1
A1
PP PP PP Co Cc
DELAY
MAGNETIC SWITCHES
MAGNETIC SWITCHES
MAGNETIC SWITCHES
MONOSTABLE
A2
EMERGENCY
Rd
A2
A2
BISTABLE
BISTABLE
REOPEN
STOP
+t
1
S
GND
N
DZ *
GND
C C
PTC PTC UP DN UP DN UP DN UP DN UP DN UP DN ON UP INSP EN CLSE ** OPN CAM/ CDOOR OPN CLSE EO EC CDOOR OPN CAM/
a b SDFS SDFS EOS EOS SDFS SDFS EOS EOS SDFS SDFS EOS EOS SFTY INSP DN INSP RE CLSE RE LS LS CLSE
Scale Sheet
2 of 9
-
1 2 3 4 5 6
27
1 2 3 4 5 6
R S T
(22V)
(22V) PP
1
2 1
AC +
5 Amps P
+
AC - 3300UF 50V 3300UF 50V
A BRIDGE A
0 17 GND
2
L1 0 0 (0Vac) 2 1
(60V)
AC + (110Vac)
P3
L2 2 1 380 60 AC -
0
Ch Cu
2 Amps 4 3 6 5
(110Vac) BRAKE END OF TRAVEL DOWN
17 110
CL Cd
4 3 6 5
SPEED GOVERNOR
R N
(PARACHUTE)
AUTO. DOOR
100nF 250V
10
SWINGING DOOR
100ohm 1/2W
1
Rd LOCK CONTACTS
Cd Cu
3
2
2
Rlight
1
21
21
21
0Vac Cd Cu Cl
(110Vac)
22
22
22
P
100nF 250V 100nF 250V 100nF 250V 100nF 250V 100nF 250V
A1
A1
A1
A1
100ohm 1/2W
100ohm 1/2W
100ohm 1/2W
100ohm 1/2W
100ohm 1/2W
GND Rlight
C Cu Cd Cl Ch C
10
A2
A2
A2
A2
0Vac 0Vac
CAR LIGHT UP DIRECTION DOWN DIRECTION SLOW SPEED HIGH SPEED
RELAY CONTACTOR CONTACTOR CONTACTOR CONTACTOR
17V 17V P GND CLGT LIGHT UP DN LOW HI CDRV
+22V (-)
1
Cl Ch
ASTRA V1.2 BOARD
2
6
U2
V2
W2
U1
V1
W1
S.&A.S. Ltd.
Jieh Chouf
Lebanon
MH support@sascontrollers.com
ASTRA WIRING DIAG: SUPPLY & OUTPUTS
D AC Contactors D
ASYNCHRONOUS MOTOR
Size FCSM No. DWG No. Rev
B - BA120W3_Supply_ContAC.Sch 1
Scale Sheet
- 3 of 9
1 2 3 4 5 6
28
1 2 3 4 5 6
A A
5CM
30CM
SWINGING DOOR AUTOMATIC DOOR
5CM P
15CM
OVERWEIGHT
P P 110VAC 110VAC
SWITCH
END OF CLOSING
OVERWEIGHT
P
DOORJAM
SWITCH
21
21
B B
SWITCH
Cc Co
OFF=INSPECTION
CLOSE WITHOUT
MICROSWITCH
22
22
ON=NORMAL
CAR STEP
5CM 5CM 5CM
(REVISION)
DELAY
PHOTOCELL
FIRST STOP FIRST STOP FIRST STOP
END OF OPENING
PP PP PP
A1
A1
A1
MAGNETIC SWITCHES
MAGNETIC SWITCHES
Cc Co Cc
MAGNETIC SWITCHES
100ohm 1/2W
100ohm 1/2W
3
MONOSTABLE
Rd
3
BISTABLE
BISTABLE
Cd Cu
EMERGENCY
A2
A2
A2
REOPEN
1
STOP
S
+t
4
DZ *
N
(0VAC)
C (0VAC) C
PTC PTC UP DN UP DN UP DN UP DN UP DN UP DN ON UP INSP EN CLSE ** OPN CAM/ CDOOR OPN CLSE EO EC CDOOR OPN CAM/
a b SDFS SDFS EOS EOS SDFS SDFS EOS EOS SDFS SDFS EOS EOS SFTY INSP DN INSP RE CLSE RE LS LS CLSE
Scale Sheet
4 of 9
-
1 2 3 4 5 6
29
1 2 3 4 5 6
P
A A
UniScroll
OR
P
UniLCD
B B
P P
A B C D COM
2 4
A
G
3 1
C C
COLLECTV="DOWN" ASTRA WIRING DIAG: CALLS / FLOOR INFORMATION - Down Collective- 10 stops
D D
Scale Sheet
5 of 9
-
1 2 3 4 5 6
30
1 2 3 4 5 6
P
A A
UniScroll
OR
P
UniLCD
B B
P P
A B C D COM
2 4
A
G
3 1
C C
S.&A.S. Ltd.
INDICATR="ENHANCED" or Jieh Chouf
"7SEGMENT" Lebanon
support@sascontrollers.com
ASTRA WIRING DIAG: CALLS / FLOOR INFORMATION - Full Collective- 6 stops
COLLECTV="FULL"
D D
Scale Sheet
6 of 9
-
1 2 3 4 5 6
31
1 2 3 4 5 6
A A
P
P
B B
COM
2 4
A
G
- 3 1
C C
S.&A.S. Ltd.
INDICATR= "7SEGMENT-" Jieh Chouf
Lebanon
support@sascontrollers.com
COLLECTV="DOWN" ASTRA WIRING DIAG: CALLS / FLOOR INFORMATION - Down Collective- 9 stops
7Seg indicator with basements
D D
Scale Sheet
7 of 9
-
1 2 3 4 5 6
32
1 2 3 4 5 6
A A
P
UniScroll
OR
P
UniLCD
B B
P P
A B C D COM
2 4
A
G
3 1
C C
S.&A.S. Ltd.
INDICATR="ENHANCED" or Jieh Chouf
"7SEGMENT" Lebanon
support@sascontrollers.com
ASTRA WIRING DIAG: CALLS / FLOOR INFORMATION - Down Collective- 5 stops
COLLECTV="DOWN 5" No multiplexing mode
D D
Scale Sheet
8 of 9
-
1 2 3 4 5 6
33
1 2 3 4 5 6
P
A A
UniScroll
OR
P
UniLCD
B B
P P
A B C D COM
2 4
A
G
3 1
C C
S.&A.S. Ltd.
INDICATR="ENHANCED" or Jieh Chouf
"7SEGMENT" Lebanon
support@sascontrollers.com
ASTRA WIRING DIAG: CALLS / FLOOR INFORMATION - Full Collective- 4 stops
COLLECTV="FULL 4"
D D
Scale Sheet
- 9 of 9
1 2 3 4 5 6
34
WHICH ELEVATO
OR CONTROLLER IS RIGH
HT FOR Y
YOU?
MicroZed v3
3.3a MicroZed v3.5a
MicroZed-A
A v3.1 MicroZed-AR
M v3.1 ASTR
RA v1.2
AC 1 speed
AC 2 speed
H
Hydraulic
VVVF F(1m/s speed)
VVVF((1.6m/s speed) — — —
VVVF(>=2m/s speed) — — — —
Magne etic Switches for
Shaftt Information
Incremmental encoder
— — — —
for dirrect approach
Sim
mplex mode
Grroup mode — — —
Dowwn Collective — —
Fulll Collective — —
Pseuudo-collective — — —
Maximum Number of
10 10 10 32 48
Stops
Serial Calls — — — —
Swiinging door
Auto omatic door
Half automatic door
Gray CCode Indicator
35
MicroZed v3
3.3a MicroZed v3.5a
MicroZed-A
A v3.1 MicroZed-AR v3.1
1 ASTR
RA v1.2
Binnary Code
In
ndicator
Enha anced Code
In
ndicator
Deccimal code
— —
In
ndicator
DC Contactors — — —
AC/DC Contactors — —
Real Time Clock — — —
Spare Outputs 1 1 2 2 8
Reserrvation Input — — —
Fulllload Input — — —
Ove erload Input — — —
Evacu uation Input — — —
Fireme en switch and
— — —
operation
Final Limit Switch
— — —
Input
In
ntegrated
— —
Evvacuation
Inspecttion Command
— —
via CCOP option
Access Control — — —
CarCalll Cancellation — — —
Double Door
— — —
E
Entrance
36
MicroZed v3
3.3a MicroZed v3.5a
MicroZed-A
A v3.1 MicroZed-AR v3.1
1 ASTR
RA v1.2
Graphical Display — —
24-Cha arx2-lines LCD
— — —
alphanumeric display
Diaggnostic Tool — — —
Englissh language
Frencch language — — —
Arabbic language — — —
Swedish language — — —
Fa
aults Log 9 9 9 15 15
Evvents log — — — —
Deskto op Application
for moonitoring and — — —
control
U
USB port
RSS485 port — — —
Firmwware Upgrade
on site
37