Sie sind auf Seite 1von 1

1. All the dimensions are in mm unless specified otherwise.

2. All thicknesses indicated are the minimum required after forming / machining. Vendor shall be
responsible for detail design and providing adequate thickness.
3. Weights indicated for estimation purpose only. Vendor shall calculate and confirm the final values.
Foundation Load Data shall be determined and furnished by Vendor on the General Arrangement
Drawing. For Design Purpose, minimum load of 40 kg / m for each cage ladder and minimum load 200 kg
/ m2 for platform with grating and handrailing shall be considered in the design till the details are furnished
by CONTRACTOR.
4. Bolt Holes shall straddle main axes
5. Nozzle Projection indicated is from outside surface of Shell / Roof) to flange gasket seating face.
Nozzle Projections from centerline of Tank (for shell nozzles) / top of shell to flange gasket seating face
rounded off to next 10 mm shall be indicated by Vendor in the General Arrangement Drawing
6. (a) Flange dimensions and facing shall be in accordance with ASME B 16.5.
(b) Surface finish of gasket contact surface for nozzle flanges other than manway flange shall be 3.2 to
6.3 micrometer Ra.
(c) Surface finish of gasket contact surface of man way and man way cover shall be as per API 650
7. All Removable Internals shall pass through Manhole.
8. Reinforcement pads shall
b􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈
􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈of Pad with Vessel in its operating position.
9. 􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈􀁈other than LWN Nozzle) shall be provided with 2 stiffeners 􀁈 30
W x 6 thk @ 90 deg. apart.
10. MDMT shall be reconfirmed by EPC CONTRACTOR.
11. Tank shall be hydrotested as per the requirements specified in paragraph 7.3.6 of API 650
12. Basic Speed at 10 m Elevation = 43 m/s (3 second gust). Exposure Category =C; Importance Factor
=1.15.
13. Site Specific design parameters for seismic desig