Sie sind auf Seite 1von 9

Perhitungan

1. Perhitungan daya thermal pada RGTT200K dengan 1 kompresor yang diaplikasikan


pada ChemCAD secara manual

Dik :
ṁ Helium : 120 Kg/s
Kcal
Cp Helium : 1,2425
Kg.℃

 Reaktor
Q = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
𝑠
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙 × ( 950 − 629,91)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 199683,1531 𝑠
│ 1000 𝐾𝑗/𝑠 = 199,6831 𝑀𝑊
 Turbin
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙𝑠 × ( 850,01 − 630,14 )℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 137162,4695 𝑠
│ 1000 𝐾𝑗/𝑠 = 137,1624 𝑀𝑊
 Kompresor
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
𝑠
= 120 𝑠 × 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙 × ( 123,89 − 29,97 )℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 58590,52685 𝑠
│ 1000 𝐾𝑗/𝑠 = 58,5905 𝑀𝑊
 IHX
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
𝑠
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙 × ( 950 − 850,01)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 62377,20166 │ = 62,3772 𝑀𝑊
𝑠 1000 𝐾𝑗/𝑠
 Recuperator
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙𝑠 × ( 629,91 − 123,89)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 315672,6831 𝑠
│ 1000 𝐾𝑗/𝑠 = 315,6726 𝑀𝑊
 Precooler
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙𝑠 × ( 124 − 29,97 )℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 58659,14863 𝑠
│ 1000 𝐾𝑗/𝑠 = 58,6591 𝑀𝑊

𝑊𝑡𝑢𝑟𝑏𝑖𝑛 − 𝑊𝐾𝑜𝑚𝑝𝑟𝑒𝑠𝑜𝑟
 Effisiensi Thermal = 𝑄𝑅𝑒𝑎𝑘𝑡𝑜𝑟
× 100%
137,1624 − 58,5905
= × 100%
199,6831

= 39,44 %

Perbandingan hasil perhitungan daya termal yang ada di jurnal dan secara
manual

Daya termal
(MW)
199,68
62,37
137,16
315,67
58,65
58,59
2. Perhitungan daya thermal pada RGTT200K dengan 2 kompresor yang diaplikasikan
pada ChemCAD secara manual

Dik :
ṁ Helium : 120 Kg/s
Kcal
Cp Helium : 1,2425
Kg.℃

 Reaktor
Q = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
𝑠
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙 × ( 950 − 628,10)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 200812,2934 │ = 200 𝑀𝑊
𝑠 1000 𝐾𝑗/𝑠

 Turbin
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 × 1,2425 │ 𝐾𝑐𝑎𝑙𝑠 × ( 850,01 − 628,91)℃
𝑠 𝐾𝑔.℃ 1
𝑠
𝐾𝑗 1 𝑀𝑊
= 137929,7858 𝑠
│ 1000 𝐾𝑗/𝑠 = 137,9297 𝑀𝑊
 IHX
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
𝑠
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙 × ( 950 − 850,01)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 62377,20166 𝑠
│ 𝐾𝑗 = 62,3772 𝑀𝑊
1000
𝑠
 Recuperator
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙𝑠 × ( 628,10 − 73,36)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 346065,8951 │ 𝐾𝑗 = 346 𝑀𝑊
𝑠 1000
𝑠

 Precooler
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 × 1,2425 │ 𝐾𝑐𝑎𝑙𝑠 × ( 74 − 29,80)℃
𝑠 𝐾𝑔.℃ 1
𝑠
𝐾𝑗 1 𝑀𝑊
= 27573,48048 𝑠
│ 𝐾𝑗 = 27,5734 𝑀𝑊
1000
𝑠

 Intercooler
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 × 1,2425 │ 𝐾𝑐𝑎𝑙𝑠 × ( 74,61 − 29,00)℃
𝑠 𝐾𝑔.℃ 1
𝑠
1 𝑀𝑊
= 28453,08698│ 𝐾𝑗 = 28,4530 𝑀𝑊
1000
𝑠
 Kompresor HPC
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 × 1,2425 │ 𝐾𝑐𝑎𝑙𝑠 × ( 73,36 − 29,00)℃
𝑠 𝐾𝑔.℃ 1
𝑠
𝐾𝑗 1 𝑀𝑊
= 27673,29398 𝑠
│ 𝐾𝑗 = 27,6732 𝑀𝑊
1000
𝑠
 Kompresor LPC
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙𝑠 × ( 74,61 − 29,80 )℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 27954,01946 𝑠
│ 𝐾𝑗 = 27,9540 𝑀𝑊
1000
𝑠

𝑊𝑡𝑢𝑟𝑏𝑖𝑛 − 𝑊𝐾𝑜𝑚𝑝𝑟𝑒𝑠𝑜𝑟
 Effisiensi Thermal = × 100%
𝑄𝑅𝑒𝑎𝑘𝑡𝑜𝑟
137,9297 − ( 27,6732 + 27,9540)
= × 100%
200

= 41,15 %
Perbandingan hasil perhitungan daya termal yang diaplikasikan pada ChemCAD
dengan yang diaplikasikan pada Hysys

Daya termal (MW)


200
62,37
137,92
346
27,57
27,95
28,45
27,67

3. Perhitungan daya thermal pada RGTT200K dengan 1 kompresor yang diaplikasikan


pada Hysys secara manual

Dik :
ṁ Helium : 120 Kg/s
Kcal
Cp Helium : 1,2425
Kg.℃

 Reaktor
Q = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙𝑠 × ( 950 − 629,9)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 199689,3914 𝑠
│ 1000 𝐾𝑗/𝑠 = 199,68 𝑀𝑊
 Turbin
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙𝑠 × ( 850 − 630 )℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 137243,568 𝑠
│ 1000 𝐾𝑗/𝑠 = 137,24 𝑀𝑊
 Recuperator
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
𝑠
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙 × ( 629,9 − 123,9 )℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 315660,2064 𝑠
│ 𝐾𝑗 = 315,66 𝑀𝑊
1000
𝑠
 Precooler
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
𝑠
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙 × ( 124 − 29,97)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 58659,14863 𝑠
│ 𝐾𝑗 = 58,65 𝑀𝑊
1000
𝑠
 Kompresor
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 × 1,2425 │ 𝐾𝑐𝑎𝑙𝑠 × ( 123,9 − 29,97 )℃
𝑠 𝐾𝑔.℃ 1
𝑠
𝐾𝑗 1 𝑀𝑊
= 58596,76519 │ 𝐾𝑗 = 58,59 𝑀𝑊
𝑠 1000
𝑠

 IHX
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 × 1,2425 │ 𝐾𝑐𝑎𝑙𝑠 × ( 950 − 850 )℃
𝑠 𝐾𝑔.℃ 1
𝑠
𝐾𝑗 1 𝑀𝑊
= 62383,44 𝑠
│ 𝐾𝑗 = 62,38 𝑀𝑊
1000
𝑠

𝑊𝑡𝑢𝑟𝑏𝑖𝑛 − 𝑊𝐾𝑜𝑚𝑝𝑟𝑒𝑠𝑜𝑟
 Effisiensi Thermal = × 100%
𝑄𝑅𝑒𝑎𝑘𝑡𝑜𝑟
137,24 − 58,59
= × 100%
199,68

= 39,38 %

Perbandingan hasil perhitungan daya termal yang diaplikasikan di ChemCAD


dengan perhitungan daya termal yang diaplikasikan di Hysys pada 1 Kompresor

Daya termal
(MW)
199,68
62,38
137,24
315,66
58,65
58,59

4. Perhitungan daya thermal pada RGTT200K dengan 2 kompresor yang diaplikasikan


pada Hysys secara manual

Dik :
ṁ Helium : 120 Kg/s
Kcal
Cp Helium : 1,2425 Kg.℃

 Reaktor
Q = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙𝑠 × ( 950 − 628,1)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 200812,2934 𝑠
│ 𝐾𝑗 = 200,81 𝑀𝑊
1000
𝑠

 IHX
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
𝑠
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙 × ( 950 − 850)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 62383,44 𝑠
│ 𝐾𝑗 = 62,38 𝑀𝑊
1000
𝑠
 Turbin
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 × 1,2425 │ 𝐾𝑐𝑎𝑙𝑠 × (850 − 628 )℃
𝑠 𝐾𝑔.℃ 1
𝑠
𝐾𝑗 1 𝑀𝑊
= 138491,2368 𝑠
│ 𝐾𝑗 = 138,49 𝑀𝑊
1000
𝑠
 Recuperator
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙𝑠 × ( 628,1 − 73,36)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 346065,8951 │ 𝐾𝑗 = 346,06 𝑀𝑊
𝑠 1000
𝑠
 Precooler
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
𝑠
= 120 𝑠 × 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙 × ( 74 − 29,80)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 27573,48048 𝑠
│ 𝐾𝑗 = 27,57 𝑀𝑊
1000
𝑠

 Intercooler
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
= 120 × 1,2425 │ 𝐾𝑐𝑎𝑙𝑠 × ( 74,63 − 29 )℃
𝑠 𝐾𝑔.℃ 1
𝑠
𝐾𝑗 1 𝑀𝑊
= 28465,56367 𝑠
│ 𝐾𝑗 = 28,46 𝑀𝑊
1000
𝑠
 HPC
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
𝑠
= 120 𝑠 × 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙 × ( 73,36 − 29)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 27673,29398 𝑠
│ 𝐾𝑗 = 27,67 𝑀𝑊
1000
𝑠
 LPC
W = ṁ x Cp x( T2 – T1 )
𝐾𝑗
𝐾𝑔 𝐾𝑐𝑎𝑙 4,184
𝑠
= 120 𝑠
× 1,2425 𝐾𝑔.℃
│ 𝐾𝑐𝑎𝑙 × ( 74,63 − 29,80)℃
1
𝑠
𝐾𝑗 1 𝑀𝑊
= 27966,49615 𝑠
│ 𝐾𝑗 = 27,96 𝑀𝑊
1000
𝑠

𝑊𝑡𝑢𝑟𝑏𝑖𝑛 − 𝑊𝐾𝑜𝑚𝑝𝑟𝑒𝑠𝑜𝑟
 Effisiensi Thermal = 𝑄𝑅𝑒𝑎𝑘𝑡𝑜𝑟
× 100%
138,49 − ( 27,67 + 27,96)
= × 100%
200,81

= 41,26%

Perbandingan hasil perhitungan daya termal yang diaplikasikan pada ChemCAD


dengan yang diaplikasikan pada Hysys pada 2 Kompresor

Daya termal (MW)


200,81
62,38
138,49
346,06
27,57
27,96
29
27,67

Perbandingan hasil perhitungan distribusi daya dan efisiensi pada sistem konversi energi
RGTT200K dengan 1 dan 2 kompresor pada aplikasi ChemCAD
Perbandingan hasil perhitungan distribusi daya dan efisiensi pada sistem konversi energi
RGTT200K dengan 1 dan 2 kompresor pada aplikasi Hysys

Komponen Utama 1 Kompresor 2 Kompresor


Sistem Konversi Energi RGTT200K
Daya Reaktor (MW) 199,68 200,81
Daya pada IHX (MW) 62,38 62.38
Daya pada Turbin gas (MW) 137,24 138,49
Daya pada Rekuperator (MW) 315,66 346,06
Daya pada Precooler (MW) 58,65 27,57
Daya pada Kompresor Tunggal (MW) 58,59 -
Daya pada Kompresor LPC (MW) - 27,96
Daya pada Kompresor HPC (MW) - 27,67
Daya pada Intercooler (MW) - 28,46
Efisiensi termal 39,38 % 41,26%

Das könnte Ihnen auch gefallen