Beruflich Dokumente
Kultur Dokumente
365C and 385C Excavators and 365C MHPU and 385C MHPU Mobile Hydraulic
Power Units Machine Electronic Control System
Media Number -RENR8067-04 Publication Date -01/12/2010
Calibration
(1) Monitoring system display
(4) OK key
Note: See Troubleshooting, Systems Operation, Testing and Adjusting, RENR8068 for more
information concerning the monitoring system.
Note: When "PASSWORD" screen appears, use the right key (3) and the left key (2) in order
to scroll through the characters. When the desired character is highlighted, press the OK key
(4) . Enter the password for service FFF2 in order to continue to the "SERVICE" screen.
Note: You can also perform the calibrations with the Cat ET.
The following is a list of calibrations that can be performed with the monitoring system.
Control Valves:
All Valves
Boom Valve
Stick Valve
Bucket Valves
Right Travel Valve
Left Travel Valve
Attachment Valve
Power Shift Pressure Valve
Check Valve:
All Calibrations
Left Lever (Forward and Back)
Left Lever (Left and Right)
Right Lever (Forward and Back)
Right Lever (Left and Right)
Left Travel Pedal
Right Travel Pedal
Modulation For Left Thumb wheel
Modulation For Right Thumb wheel
Left Attachment Pedal
Right Attachment Pedal
Engine Speed
Fan Speed
All Valves
Perform the following steps in order to calibrate all valves:
1. Main Menu
2. Service
4. Calibrations
5. Control Valves
6. "ALL VALVE"
When a blue number is displayed, perform the operation that corresponds with the step in
table 1 for the number that is displayed.
Table 1
Step Operation
1 Press the "OK" key in order to go to the next step.
2 Raise the boom and the stick to the maximum position. Then press the "OK" key.
3 Set the lever for hydraulic oil to the UNLOCK position.
4 Press the OK key in order to go to the next step.
5 Hold the left lever in the BACK position.
6 Hold the left lever in the BACK position.
7 Press the "OK" key in order to go to the next step.
8 Hold the left lever in the BACK position.
9 Hold the left lever in the BACK position.
10 Hold the left lever in the BACK position.
11 Sustain the left lever BACK.
12 Release all levers and release all pedals.
13 Press the OK key in order to go to the next step.
14 End of the calibration.
Boom Valve
Perform the following steps In order to calibrate the boom valve:
1. Main Menu
2. Service
4. Calibrations
5. Control Valves
6. "BOOM VALVE"
When a blue number is displayed, perform the operation that corresponds with the step in
table 2 for the number that is displayed.
Table 2
Step Operation
2 Raise the boom and the stick to the maximum position. Then press the "OK" key.
Stick Valve
Perform the following steps in order to calibrate the stick valve:
1. Main Menu
2. Service
4. Calibrations
5. Control Valves
6. "STICK VALVE"
When a blue number is displayed perform the operation that corresponds with the step in
table 3 for the number that is displayed.
Table 3
Step Operation
2 Raise the boom and the stick to the maximum position. Then press the "OK" key.
Bucket Valve
Perform the following steps in order to calibrate the bucket valve:
1. Main Menu
2. Service
4. Calibrations
5. Control Valves
6. "BUCKET VALVE"
When a blue number is displayed, perform the operation that corresponds with the step in
table 4 for the number that is displayed.
Table 4
Step Operation
2 Raise the boom and the stick to the maximum position. Then press the "OK" key.
1. Main Menu
2. Service
4. Calibrations
5. Control Valves
When a blue number is displayed perform the operation that corresponds with the step in
table 5 for the number that is displayed.
Table 5
Step Operation
2 Raise the boom and the stick to the maximum position. Then press the "OK" key.
1. Main Menu
2. Service
4. Calibrations
5. Control Valves
When a blue number is displayed, perform the operation that corresponds with the step in
table 6 for the number that is displayed.
Table 6
Step Operation
2 Raise the boom and the stick to the maximum position. Then press the "OK" key.
Attachment Valve
Perform the following steps in order to calibrate the attachment valve:
1. Main Menu
2. Service
4. Calibrations
5. Control Valves
6. "ATCH VALVE"
When a blue number is displayed, perform the operation that corresponds with the step in
table 7 for the number that is displayed.
Table 7
Step Operation
2 Raise the boom and the stick to the maximum position. Then press the "OK" key.
1. Main Menu
2. Service
When a blue number is displayed, perform the operation that corresponds with the step in
table 8 for the number that is displayed.
Note: The Engine Speed Dial must be at Position 10 in order to successfully complete the
calibration.
Table 8
Step Operation
1 Connect the pressure gauge. Then press the "OK" key in order to go to the next step.
Press the right key or the left key in order to increase or decrease the current value. Tune
2 the pressure to the target. When you finish adjusting then press the "OK" key to go to the
next step.
3 Go to step 2.
1. Main Menu
2. Service
4. Calibrations
5. Check Valves
6. "BLCV"
When a blue number is displayed, perform the operation that corresponds with the step in
table 9 for the number that is displayed.
Table 9
Step Operation
2 Raise the boom and the stick to the maximum position. Then press the "OK" key.
1. Main Menu
2. Service
4. Calibrations
5. Check Valves
6. "SLCV"
When a blue number is displayed, perform the operation that corresponds with the step in
table 10 for the number that is displayed.
Table 10
Step Operation
All Calibrations
Perform the following steps in order to calibrate all calibrations:
1. Main Menu
2. Service
4. Calibration
6. "ALL"
When a blue number is displayed, perform the operation that corresponds with the step in
table 11 for the number that is displayed.
Table 11
Step Operation
3 Move the controls to both stops. Then, Press the "OK" key.
4 Press the "OK" key in order to go to the next step.
1. Main Menu
2. Service
4. Calibration
When a blue number is displayed, perform the operation that corresponds with the step in
table 12 for the number that is displayed.
Table 12
Step Operation
3 Move the controls to both stops. Then, Press the "OK" key.
1. Main Menu
2. Service
4. Calibration
When a blue number is displayed, perform the operation that corresponds with the step in
table 13 for the number that is displayed.
Table 13
Step Operation
3 Move the controls to both stops. Then, Press the "OK" key.
1. Main Menu
2. Service
4. Calibration
When a blue number is displayed, perform the operation that corresponds with the step in
table 14 for the number that is displayed.
Table 14
Step Operation
3 Move the controls to both stops. Then, Press the "OK" key.
1. Main Menu
2. Service
4. Calibration
When a blue number is displayed, perform the operation that corresponds with the step in
table 15 for the number that is displayed.
Table 15
Step Operation
1. Main Menu
2. Service
4. Calibration
When a blue number is displayed perform the operation that corresponds with the step in
table 16 for the number that is displayed.
Table 16
Step Operation
3 Move the controls to both stops. Then, Press the "OK" key.
2. Service
4. Calibration
When a blue number is displayed, perform the operation that corresponds with the step in
table 17 for the number that is displayed.
Table 17
Step Operation
3 Move the controls to both stops. Then, Press the "OK" key.
1. Main Menu
2. Service
4. Calibration
Table 18
Step Operation
3 Move the controls to both stops. Then, Press the "OK" key.
1. Main Menu
2. Service
4. Calibration
6. "MOD R THUMBWHEEL"
When a blue number is displayed, perform the operation that corresponds with the step in
table 19 for the number that is displayed.
Table 19
Step Operation
3 Move the controls to both stops. Then, Press the "OK" key.
1. Main Menu
2. Service
4. Calibration
When a blue number is displayed, perform the operation that corresponds with the step in
table 20 for the number that is displayed.
Table 20
Step Operation
3 Move the controls to both stops. Then, Press the "OK" key.
1. Main Menu
2. Service
4. Calibration
When a blue number is displayed, perform the operation that corresponds with the step in
table 21 for the number that is displayed.
Table 21
Step Operation
3 Move the controls to both stops. Then, Press the "OK" key.
Engine Speed
Perform the following steps in order to calibrate the engine speed:
1. Main Menu
2. Service
4. Calibration
5. "ENGINE SPEED"
When a blue number is displayed, perform the operation that corresponds with the step in
table 22 for the number that is displayed.
Table 22
Step Operation
3 -
4 -
5 -
6 -
7 -
8 -
9 -
10 -
Fan Speed
Perform the following steps in order to calibrate the fan speed:
1. Main Menu
2. Service
4. Calibration
5. "FAN SPEED"
When a blue number is displayed, perform the operation that corresponds with the step in
table 23 for the number that is displayed.
Table 23
Step Operation
Connect the speed sensor to the fan. Then press the "OK" key in order to go to the next
1
step.
Press the right key or the left key in order to increase or decrease the current value. Tune
2 the fan speed to the target. When you finish adjusting the fan speed then press the "OK"
key.
3 Go to step 2.
Copyright 1993 - 2014 Caterpillar Inc. Thu Mar 06 2014 23:28:49 GMT+0800 (China Standard Time)
All Rights Reserved.
Private Network For SIS Licensees.