Sie sind auf Seite 1von 106

3.a.

3 PRICING PREAMBLES

3.a.3.1 GENERAL

1. The bidder should allow against the items or in the prices for everything contained in this Bill of Quantities
which has a monetary value.

2. Lump sums shall not be given where unit rates are applicable.

3. Unit rates and extensions shall be given in Sri Lankan Rupees (SLR) to a maximum of two places decimals.

4. The various documents collectively referred to herein as the Bills of Quantities jointly constitute the Bill of
Quantities referred to in the Conditions of Contract.

5. The method adopted in the preparation of bills of quantities shall be adopted for re-measurement of
completed works.

6. Works have been measured net as fixed in position and each measurement shall be taken to the nearest
10millimeters.

7. Items in the preamble section of this bill of quantities are deemed to qualify and to form part of every
description of measured work to which they refer including composite items.

8. The Contractor shall not use this-Bill of Quantities as a Construction programme or for the purposes of
ordering materials or arranging Sub-Contracts. The references for these activities shall be the drawings,
specifications and instructions issued by the Engineer.

9. The descriptions in the Bills of Quantities are for identification purposes only and the Contractor is referred
to the Drawings, Specifications and Schedules for complete information regarding all relevant descriptions,
quality, dimensions, capacities, design parameters and the like.

10. These pricing preambles are a standard and comprehensive set and hence may exceed the requirements
of this particular project.

11. The Quantities given in the Bill of Quantities are estimated only and are intended to give an indication of
the extent of the work to be carried out. Payment will however be made on Measure and pay basis.

12. The Quantities set out in the Bill of Quantities are provisional and cover the approximate scope of the
work, which is anticipated to be performed by the Contractor.

13. The rates and prices entered in the Bill of Quantities shall, except in so far as it is otherwise provided
under the Contract include cost of all constructional plant, supervision, materials erection and maintenance,
duties/levies together with all general risks, liabilities and obligations as set out or implied in the Contract.

14. The rate or price shall be entered against each item in the Bill of Quantities, whether quantities are stated
or not. The cost of items against which Contractor has failed to enter rate or prices shall be deemed to be
covered in other rates and prices in the Bill of Quantities.

15. The whole cost of complying with the provisions of the Contract shall be included in the items provided in
the Bill of Quantities and where no items are provided the cost shall be deemed to be distributed among the
rates and prices entered for the related items of work.

16. General directions and descriptions of work and materials are not necessarily repeated nor summarized
in the Bill of Quantities. Reference to the relevant sections of the Contract Document shall be made before
entering prices each against item in the priced Bill of Quantities.

17. Provisional sums included and so designated in the Bill of Quantities shall be expended in whole or part
at the direction and discretion of the Engineer in accordance with the stipulation made under General
Conditions of Contract and/or Particular Conditions of Contract.

18. Where the determination for payment purposes of the quantity of any item of work depends upon the
measurement of existing features or ground levels and the like, then prior to carrying out any operations
which might affect such measurement, the Contractor shall first take such levels and measurements as the
Engineer may direct and, after the Engineer has had the opportunity to check the same, they shall be
certified as agreed by both the Engineer and the Contractor. In the event that the Contractor fails to observe
the above procedure, the Engineer shall determine the quantity to be assumed for payment purposes using
the best information available to him, and his decision in the matter shall be final.

19. Tenderer should visit the site and acquaint themselves with all existing conditions, the nature and extent
of work to be done under this contract ascertaining the conditions governing access to the site, the extent of
work and accordingly include for, in their prices

20. The following abbreviations are used in the Bill of Quantities and shall carry the meanings as listed
hereunder:

Sq.ft - Square feet


cm - Centimetre
L.Ft - Linear feet
Sqrs - Squares
Mm - Millimetre
m - Liner meter
m2 - square meter
m3 - cubic meter
kg - Kilogram
t - metric ton
pr - Pair
nr - Number
hr - Hour
P.S. - Provisional sum
BOQ - Bills of Quantities
BS - British Standard

Prices also deemed to include:

1. Rate shall be comprehensive and include for the following:

a) All obligations imposed by the Contract.


b) Complying in every respect with the requirements and the consideration of the specifications and
drawings.
c) All considerations arising from the definitions incorporated into each preamble section.
d) Labour for fixing and all associated costs.
e) Materials and goods & all associated costs.
f) Fixing and or fixing materials and goods in any position, hoisting to any height.
g) Use of scaffolding, plant, equipment and tools
h) Any additional labour usually associated with measured items.
i) All necessary protection of the works, removing all casings and temporary coverings and making good and
clearing away upon completion.
2. All measurements are net and the rates shall include for laps, waste, working space and trade or
traditional allowance.

3. The pricing of materials shall take account of the following:


a) Pricing Preambles, Drawings and Specifications shall apply reciprocally between sections of the works
unless otherwise described.
b) Materials shall be of the best quality available unless otherwise described.
c) All materials shall be transported, handled, stored and fixed in accordance with the printed instructions or
recommendations of their manufacturer or suppliers.
d) Protection of completed work, all casing and temporary coverings and making good and clearing away
upon completion. Building paper, damp proof membrane, quilts and all non-rigid sheet materials shall
include cutting or forming holes and notchings and-extra labour of turning up at edges and the like.

4. Duct shall include draw wires.

5. Holes, mortices, pockets, grooves, chases and the like and items described as "built in" and "cast in" shall
include making in its fullest sense and through, around, into, over and up to the items concerned. '

6. Items described as "cut" shall include general making good similarly.

7. Where the word "allow" is used the cost of the items shall be the responsibility of the Contractor.

8.The Contractor shall obtain from all sub-contractors (where nominated or not) their requirements for all
recesses, chases, holes and the like in order that they may be built in or formed as the work proceeds. No
additional charges shall be allowed for cutting recesses, chases and holes and the like after the construction
of the works.

9. In the event of their being any discrepancies between details on drawings, descriptions in specifications
and descriptions in the bills of quantities then the rates and pricing shall be deemed to relate to the
documents order of precedence set out in the Form of Agreement.

10. The amounts set against any items of profit shall include for all costs in connection with letters of credit,
bank charges, interest charges and insurance after the materials come under the control of the Contractor.

11. The contractor should leave the whole of the works ready for immediate occupation to the satisfaction of
the Engineer including the following:
a) Cleaning and touching up the buildings both inside and out, leaving all surfaces free of cracks, blemishes or
splashes.
b) Easing, oiling and adjusting and making good of finishes to all fittings, doors, windows, ironmongery and
the like.
c) Cleaning and polishing all marbles, glasses, anodized aluminium and sanitary ware, including the removal
of all protective coverings, paint splashes and the like. Replacement of all or any chipped, cracked or broken
items.
d) Balancing of air conditioning installation where applicable
e) Removal of rubbish, debris or excess spoil from the site area and raking over and cleaning all unused parts
of the site area.

Fix Only:

The expression "fix only" used in these Bills of Quantities means that the Contractor shall provide the
following facilities:
a) Fixing shall be understood to include unloading, storing, distributing and hoisting the goods and materials.
b) Supplying full size templates, giving and "marking dimensions and taking responsibility for their accuracy.
c) Getting in, protecting, handling, distributing and placing in position and assembling as required.
d) Casing-up and protection, including clearing away protection on completion of the works including sub-
contractors' works
e) Full costs of replacement of any items, which are damaged, broken, lost or stolen after the acceptance of
the items from the supplier or Employer and until handing over the complete works.
f) Other necessary and usual facilities and documentation.

Supply Only:

The expression "Supply only" used in these Bills of Quantities means that the Contractor is provide for
everything as defined in relevant method of measurement in connection with such items .except fixing in
position. Supply only" shall further include:
a) Labour and all associated costs
b) Materials, goods and all associated costs
c) Provision of plants
d) Temporary works
e) Establishment charges, overheads and profits

3.a.3.2 SITE-PREPARATION:

3.a.3.2.1 Extent of site clearing shall be determined by the Engineer. No payment shall be made for
additional quantities unless the Engineer expressly required.

3.a.3.2.2 No trees shall be removed without consent of the Engineer.

3.a.3.3 EXCAVATION & EARTHWORKS

3.a.3.3.1 Prices also to include:

Rates for excavation shall be deemed to include for the following.


a) Excavating by whatever means are necessary including hand excavation in any kind of ground except rock
and boulder rock.
b) Leveling bottom of excavations.
c) Trimming or grading ground to produce level surfaces or surfaces to falls or slopes.
d) Compacting to bottom of excavation and to filled surfaces
e) Keeping free from water including any dewatering as necessary.
f) Any hand excavation required around existing services or the like.
g) Testing the bottom of excavations for foundations as instructed.
h) Testing compaction on filled surfaces where necessary
i) Backfilling with selected excavated material unless measured otherwise.
j) Removing surplus excavated material from the site and dumping at approved location. Contractor shall
arrange and obtain necessary permission from relevant authorities for disposal and dumping of earth.
k) Contractor shall provide' due protection to avoid any damages to temporary work, any new or old
structures during excavation.
l) Necessary Planking and strutting
m) Working space if required
n) Bulking after excavation.
o) Excavating at any height or any depth

3.a.3.3.2 The rates for excavation of trenches for services, pipes or drain pipes shall include for deepening
and widening as necessary to enable the barrels of pipes, ducts, etc., to rest on firm ground and to facilitate
jointing:

3.a.3.3.3 The rates for items of imported fillings, graded gravel fillings etc, shall include for:.

a) Leveling and compacting as required by the specification


b) Grading to slopes and falls
c) Special compacting to form vertical or battering faces
d) Forming sinking

3.a.3.3.4 Volume of excavation for pile cap shall be measured as shown in drawings, but deduction shall be
made for the volume, already excavated for pile hacking under previous contract.

3.a.3.3.5 The rate for filling with excavated material is deemed to include for using existing excavated
material at the site.

3.a.3.3.6 Excavating top soil is carried out, if the Engineer expressly required only.

3.a.3.3.7 Contractor shall provide 10 years guarantee for anti-termite treatment.

ROCK EXCAVATION

Rates for rock excavation shall be strictly as per specifications and to be priced accordingly.
Rates for rock excavation shall include for whole process as per specifications and leveling of the bottom etc.,
by using approved equipment.
The contractor shall forward the method statement and obtain prior approval from the Engineer.
Rate shall include for cart away weathered rock to waste as directed.
Useful hard rock can be used for construction work with price adjustment, or delivered to the officer in
charge.

3.a.3.4 CONCRETE WORK

3.a.3.4.1 Concrete:

(i) The rates for concrete works shall include for the following:

a) Concrete test cubes as instructed by the Engineer and testing costs


b) Rate shall include for plant for mixing, handling, hoisting, depositing, compacting, vibrating, curing and
making good after removal of formwork.
c) Forming construction joints or the like
d) Forming joints between new concrete and existing concrete unless otherwise measured separately.
e) Shuttering to sloping upper surfaces not exceeding 15 degrees from horizontal
g) All necessary keys to concrete surfaces to receive in-situ finishes
(h)All costs in connection with the construction of "kickers”
(i) Providing admixtures if required
j) The rates for blinding shall include for the following.
i) All necessary shuttering to edges or extra volume of concrete used in lieu of formwork.
ii) Forming sloping upper surfaces where required.

(ii) All concrete works shall comply with the relevant specifications, filled into formwork and well
packed around reinforcement.
(iii) Item for ground slab is deemed to include for thickening for partition walls

(iv) Concrete items are deemed to include projections, nibs, fillets and external splays

(v) Concrete in suspended slabs is deemed to include up stand curbs

(vi) Proportioning of Concrete Materials and Strength

Mix Proportions and Strengths

The mix proportions and compressive strengths are given below. The mix proportions are indicated by the
volumetric ratios of cement; fine aggregate’; coarse aggregate. The concrete to be used in any locations in
specified on the Drawings by the mix proportions followed by the nominal maximum size of coarse aggregate
in brackets.

Nominal Maximum Mean Cube Minimum Cube


Mix Proportions Size of Coarese Strength at 28 Strength at 28
Aggregate (mm) daysN/mm2 daysN/mm2
1:4:8 37.5 12 8
1:3:6 37.5 17 13
1:2:4 37.5 23 17
1:2:4 20 28 20
1:1.5:3 20 29 21
1:1.5:3 10 29 21

An additional 1o percent of cement over and above the specified mix proportion shall be used when hand
nixing is done. The water / cement ratio by weight shall not exceed 0.55.

Workability of concrete

The workability or consistency of fresh concrete shall be such that the concrete is suitable for the conditions
of handing and placing so that after compaction it surrounds and grips all reinforcements and completely fills
the form work.

The degree of workability shall depended on the nature of work and the method of placement; whether with
vibration or without vibration.

For purposes of these specifications the degree of workability shall be classified as low, medium and high and
shall normally be assessed by means of the slump test.

Generally accepted values of slump, in relation to the degree or workability and the aggregate used, are
given in table below.

Nominal max. size of


Degree of Workability Slump (mm)
aggregate (mm)
12.5 0-12
Low 20 12-25
37.5 25-50
Medium 12.5 12-25
20 25-50
37.5 50-100
12.5 25-75
High 20 50-125
37.5 100-150

Testing of Concrete for Acceptance

General

Concrete shall be tested by determining the crushing strength of 150 mm cubes at 28 days. Where so
required, an early assessment of the 28 days strength shall be made by carrying out tests at 7 days on the
assumption that 65% of the 28 days strength is achieved in 7 days.

(vii) Hand Mixing

Hand Mixing where permitted, shall be carried out on a smooth watertight platform large enough to allow
efficient turning over of the constituents of concrete before and after adding the water. Mixing platform
shall be so formed that no foreign material gets mixed up with the concrete and the mixing water does not
flow out of the mixing area.

(viii) Placing and compaction of concrete

Prior to placing of concrete all formwork and reinforcement therein shall be cleaned of all extraneous
material and dust and made fee of any standing water. It shall be ensured that all formwork is made leak
proof and that there is no loss of mixing water or grout from the concrete.

All mixed concrete shall be placed and compacted in the formwork, using approved vibrators of the internal,
external or screed types, or combinations there of depending on the type of job. Where approved, steel rods
may also be used for the purpose in addition to the vibrators. The adequacy of the compacting equipment or
the suitability of the compacting method shall be determined depending on the requirements. Use of steel
roads only for compaction shall be restored to only in small jobs and in low strength concretes.

In all cases of continuous concreting, fresh concrete shall be placed before the already laid concrete isles
than 30 minutes old and where this time gap is exceeded a construction joint shall normally be formed prior
to continuing with the concreting. All concrete shall be placed and compacted in horizontal layers normally
not exceeding 300 mm in depth except where internal vibrators are used when the depth may be increased
up to a maximum of about 450mm.

No concrete shall be dropped from a height greater than about 1.5 meters. Where chutes are used for
placing of concrete they shall be kept clean and used in a manner to prevent segregation. When concreting
has to be resumed on a surface, which has hardened, it shall be roughened, swept clean thoroughly wetted
and covered with a thin layer of cement grout or cement mortar as approved. Semi-hardened surfaces shall
be well brushed to remove all laitance, cleaned and covered with a thin layer of cement grout prior to
overlaying with fresh concrete.

(ix) Curing of Concrete

Freshly laid concrete shall be kept undisturbed and protected form the effects of sun and rain from drying
out till it hardens. Once hardened, the concrete shall continuously be cured in a moist atmosphere for a
minimum period of 7 days and for a further period if so specified.
The method of curing shall depend on the type of member to be cured. Bridge deck slabs and other slabs
shall be dept covered with burlap, jutehession or other similar water absorbing material which shall be kept
moist throughout the curing period. Such slabs may be kept covered with wet sand or even kept ponded up
with water. Sides of such slabs may have to be kept continuously sprinkled with water.

3.a.3.4.2 Formwork

(i) The rates for formwork shall include for the following:

a) All cutting and waste including raking, curved or circular cutting.


b) Setting up strutting and supporting at any height above the structure subject to any limitations imposed by
the Engineer including all props, stays, struts, wedges and bolts etc.
c) Coating of shutter oil
d) Easing; striking, removing and cleaning the surface of concrete.
e) Overlaps and passings at angles and labour at intersections
f) Shortening struts or shapes and re-strutting or re-shoring where required.
g) Rubbing down, filling and making good the surface of concrete after removal of shuttering.
h) Cutting or notching shutters or moulds to in-situ or precast concrete around projecting reinforcement.
i) Scaffolding if necessary
j) Formwork has been measured the net contact surface between concrete and formwork.
k) Formwork to beams, columns and casings deemed to include ends.

(ii) The rates for wrought shuttering/ shuttering to produce a special finish shall include for the
following.

a) Any necessary rubbing down or filling allowed by the specification to produce the finish required.
b) Cutting out and re-casting unsatisfactory work or work not fulfilling the requirement of the specification or
carrying out remedial or any other work required by the Engineer as an alternative to cutting out
substandard work.

(iii) Removal of Formwork

The formwork shall be so removed as not to caused any damaged to concrete due to shock or vibration.

Formwork shall normally be stripped in the following order;

a. Shutters to vertical faces, eg. Side of columns, beams and walls


b. Shutters forming soffits to roof and floor slabs, horizontal and inclined canopies, etc.
c. Shutters forming soffits of beams and girders.

Time of Removal

In no circumstances shall forms be struck until the concrete reaches a strength of at least twice the stress to
which the concrete may be subjected at the time of strike. Where possible, the for as long as possible, as it
would assist curing, Forms shall be eased out carefully in order to prevent the load being transferred
suddenly to the partly hardened concrete. The period that shall elapse after the concrete has been laid,
before easing and removal of centering and shuttering is undertaken shall be as given in Table below;
Period for Ordinary Portland
Part of Structure
Cement without admixtures
Sides of foundations, columns, beams and walls 24 hours

Under sides of slabs of upto 4.5 metres span 7 days

Under sides of slabs of above 4.5 metres span and 14 days


under sides of beams and arches upto 6 metres span.

Under sides of beams and arches over 6 metres span 21 days


and upto 9 metres span

In the case of other construction as an indication, only the minimum period between the completion of
concreting and the removal of frame work shall be taken as follows:-

Vertical Faces to Mass Concrete - 24 hours


Vertical Faces to Reinforced Concrete - 24 hours
Support to soffits of beams, slabs, etc. - 14 days

3.a.3.4.3 Reinforcement

(i) Reinforcement bars should comply with specifications in BS 4449: 1988 and mesh reinforcement
with BS 4483: 1985. Steel reinforcing bars considered in the design are high yield strength bars
for diameters 10, 12, 16, 20, 25; the characteristic strength should be 460 N/mm2.

(ii) Detailing is prepared on the assumption of the use of 6m bar lengths.

(iii) 6mm diameter bars shown in reinforcement details are mild steel. (fy=250 N/mm2)

(iv) The rates for bar reinforcement shall include for the following:

a) Positioning and protecting starter bars


b) Straightening (if required), cutting to length and bending reinforcement to required shape.
c) Cleaning and wire brushing
d) Supporting in position (chairs etc) during concreting (excluding links and stirrups)
e) Binding wire, ties and distance pieces.
f) Additional cutting and bonding in connection with holes, mortices, pockets, grooves, chases
and the like.
g) Bends, hooks and laps shall be measured with the quantities.
h) Preparation of bar reinforcement schedule for Engineer's approval before starting the work.

(v) The rates for mesh reinforcement shall include for the following:
a) Straight, raking, curved and circular cutting and waste, bending to profiles and laps as required
by the drawings and specifications.
b) Supporting in position during concreting (excluding special chairs), binding wires and distance
pieces.
c) Cutting, bending and notching around all obstructions.

(vi) For the purpose of measurement length of bar shall be considered as 6000mm.

(vii) Spacers for achieving Cover to Reinforcement;

Specified concrete cover to reinforcement bars should be provided using cover blocks. Chairs should be used
to support top horizontal reinforcement and to separate vertical reinforcement in walls.

3.a.3.4.4 Pre-Cast Concrete:

(i) The rates for pre-cast concrete shall include for the following:

a) Provisions of moulds
b) Forming a fair face finish in accordance with the specifications
c) Hacking or forming keys to all other surfaces
d) Lifting hooks or other devices approved by the Engineer for positioning
e) Hoisting and fixing in position to approval of the Engineer.
f) Bedding jointing in mortar as specified.
g) All necessary temporary struts or supports
h) Sills and copings etc. shall include for plain ends and angles where necessary.

3.a.3.5 MASONRY

3.a.3.5.1 Brick Work, Block Work and Rubble Work:

(i) The rates for block or brick walls shall include for the following:

a) Straight, raking, curved and circular rough or fair cutting, plumbing at angles, cutting and bonding at
angles, openings and intersections, building into and/or against adjacent work, wedging and pinning up to
soffits.
b) Special or concrete filled blocks at angles, door, window and openings or the like, and intersections and
load bearing wall.
c) Providing any means necessary to prevent concrete cast on hollow block work or over cavities from falling
into voids or cavities (subject to the approval of the Engineer)
d) Preparation of surface to receive any external wall finish.
e) Grouting up at back of walls built against other construction.
f) All necessary cast in wall ties at junction between block work and concrete or between brickworks and
concrete.
g) All necessary expansion, contraction joints, slips strip or the like.
h) Measures to prevent cracks at joints of different materials and at joints between new and existing work.
i) Providing pipe sleeves through walls.
j) Preparation of existing surface for proper bonding.
k) Scaffolding if necessary
l) Reinforcement to in fill RCC concrete
m) Stiffeners for all 115mm thick walls exceeding 2400mm length and up to the ceiling height.
n) Builder's work in connection with services.

(ii) The rates for block walls and brick walls shall include for the following additional Labourers.

a) Cutting or forming chases or grooves for slabs, partitions, staircases, etc.


b) Cutting grooves for water bars, flashings and the like and making good and pointing in similar mortar.
c) Building in or cutting and pinning in and making good ends of lintels, brackets, Timber, steelwork, and the
like.
d) Building in or cutting for and making good around pipes, ducting, fittings and the like

(iii) Brick walls are deemed to include walls in external ducts.

3.a.3.6 WATERPROOFING:

3.a.3.6.1 The rates for work in this section shall include for the following:

a) Remove all loose and foreign materials and clean surface to receive water proofing materials.
b) Laps, seams and narrow widths, straight, raking curved and circular cutting and all consequent wastage,
fillets, arises, angles, chases for tucking in etc., returned ends and dressed ends on flashings, dressing up over
up stands and around and into gargoyles, rainwater outlets, vent pipes and the like.
c) Any additional or special materials at construction joints, expansion joints, edges and corners etc.
d) Repairing surface cracks and filling uneven surface with approved materials.
e) Base screed, temporary screed and protection screed unless measured separately.
f) Tropical grade mastic pointing to all wall flashings.
g) Testing as per Engineer's Instructions
h) Work to be done as per standard details necessary for complete system but not measured.
i) Providing all necessary tools and any other equipment required as recommended by the manufacturer.
j) Providing product samples, finished specimen areas etc., as required by the Architect
k) Forming or chasing groves, into masonry walls, concrete walls, concrete walls and slabs rebates etc., where
necessary and turning waterproofing materials into chases and pointing as specified
l) Lining to rain water outlets, cesspools, brackets, collars and filling around pipes, railing standards and the
like
m) Cutting to line and jointing new to old asphalt
n) Obtaining manufacturer’s supervisory/consultancy services if necessary and providing and acceptable
guarantees for 10 years in the name of the employer for the product and the workmanship.
o) Submitting a detailed set of shop drawings approved by manufacturer to incorporate all construction and
expansion joints as shown in drawings, structural and services elements, other details encountered in the
areas to be waterproofed and with details against settlements between two buildings with reference to
manufacturer’s proprietary details, specials and techniques. The arrangements shown in tender drawings are
for proposes of guidance only and not construction drawings.
p) Working at any given height.
q) Application of water proofing materials to specifications and manufacturer’s recommendation and as per
approved shop drawings to cover all surfaces including angle fillets, chasings, sealing of construction joints
and expansion joints, settlements joints etc.
r) Submitting pre-shipment certificates by an acceptable international Surveyor certifying the product with
respect to :-
i. Source and country of manufacture.
ii. Country of Origin
iii. Conformity to specification
iv. Conformity to system offered
v. Conformity to the product offered.

3.a.3.7 STRUCTURAL STEEL WORK

3.a.3.7.1 The rates for metal work shall include for the following:

a) All fabrications and erections


b) Preparation of shop drawings and obtaining approval from the Engineer.
c) Angles and ends
d) Application of two coats of anti-corrosive and paint to Engineer's approval
e) Holes, notches, slots and the like
f) Fixing with appropriate non-corroding countersunk screws including holes unless otherwise described.
g) Riveted and bolted work shall include rivets, bolts and holes.
h) Approved protection to cut ends or holes in galvanized work or other applied finish.
i) Metal door frame shall include for assembling, fixing with clamps, and filling with mortar, temporary
supports and removal of base ties.
j) Floor plates, duct covers and the like shall include narrow widths laying in position and for all holes, slots
and the like making good.

3.a.3.8 NON-STRUCTURAL STEEL WORK

3.a.3.8.1 All items in structural steel work shall equally apply to "Non -Structural Steelwork"

3.a.3.8.2 The rates for steel Work shall include for the following:

a) All fabrications and fixing in positions


b) Uncovering, cleaning and polishing
c) Preparation of shop drawings and obtaining approval from the Engineer.
d) Sub frames if specified
e) Beadings and sealant as required
f) Rates for doors and windows shall include for approved high quality ironmongery with master key system
as specified.

3.a.3.9 WOODWORK

3.a.3.9.1 Woodwork shall be deemed to be fixed with non-corroding nails and screws unless otherwise
described.

3.a.3.9.2 The rates for woodwork shall include for the following:

a) Working to size and shape including short lengths, mitres and ends.
b) All joints in the running length including structural joints.
c) Cutting and fittings to steelwork, trimming around openings, notchings, boring and sinking.
d) Treating all timber by vacuum pressure impregnation with copper chrome boron (CCB) preservatives or
equivalent.

3.a.3.9.3 Sizes given are nominal unless stated "finished size"


3.a.3.9.4 Doors and Windows
Rates are deemed to include for master key system as specified.

3.a.3.9.5 Glazed doors and windows are deemed to include;

a) Panes of any size


b) All straight, raking, curved and circular cutting and all consequent wastage
c) Patterned and wired glass shall include aligning adjacent panes

3.a.3.9.6 Each door and window sash shall be fitted with the accessories indicated in the specification and
schedule and no extra payment whatsoever will be made for any standard fittings and accessories even if
such are not incorporated in the specification, schedule and detail drawings.

3.a.3.10 ROOF COVERING & ROOF PLUMBING

3.a.3.10.1 Rate for roof covering shall include for;

a) J bolts, washers, nuts and all necessary fixing accessories


b) Forming opening for ventilators/ extractions
c) Straight, raking or curved cutting
d) Forming required shape (pitched or curved)

3.a.3.10.2 Rate for eave gutter shall include for;

(a) G.I fixing brackets at 300mm intervals unless stated otherwise


(b) Gutter end caps
(c) Extra material and labour on jointing with down pipes
(d) Any special joints and connections
(e) Gutters to straight or curved on plan

3.a.3.10.3 Rate for down pipes shall include for;

(a) G.I fixing brackets at 300mm intervals unless stated otherwise


(b) Extra labour and material in connection with making bends
(c) Any special joints and connections
(d) Pipes to vertical or angle

3.a.3.11 PLUMBING & SANITARY INSTALLATION:

3.a.3.11.1 The unit prices for furnishing, laying and jointing UPVC pipes shall be deemed to include, but not
limited to the cost of excavation in trenches, covering joints in cement concrete grade 15 using 25 mm
graded aggregate where necessary, refill of the excavated trenches in compacted layers not exceeding 150
mm thick and /or chasing the pipes in walls and columns covering up and finishing and/or embedding pipes
in concrete columns and slabs and/or fixing pipes to undersides/ soffits of slabs and vertical faces of columns
and walls with brackets and/or taking the pipes through rubble masonry foundations and/or block work /
brick walls and/or concrete slabs by means of pipe sleeves of larger size embedded therein and in addition
the cost of all accessories and fittings such as sockets, bends, elbows, tees, Y junctions, end caps and cleaning
eyes, except such items as are listed hereinafter which shall be measured and paid separately.
3.a.3.11.2 The rates for pipe works shall include for the following:

a) All cutting, short lengths


b) Elbows, bends, tees, stop ends, rodding eyes, junctions, reducers inspection opening and all other similar
fittings on pipes whatever the diameter if not measured separately.
c) Pipe sleeves through walls
d) Thrust blocks as required
e) Builders work

3.a.3.11.3 The rates for pipes in trenches shall include;

a) Concrete or granular bed & surrounds to pipes and any necessary formwork as required by the
Specifications.
b) Caution tapes and tiles as specified.
c) Excavation of trenches. The rates for excavating trenches shall include for all related work described in
preambles for excavation and earth work.

3.a.3.11.4 Rates for structures such as manholes, chambers, gullies, septic tanks, soakage pits shall include
for concrete, formwork, reinforcement, brick walls, excavation including related work described in preambles
for excavation and earthwork, piping, haunching and benching and all related work as shown on detail
drawing.

3.a.3.11.5 The rates for sanitary fittings and accessories shall include for the following unless otherwise
measured separately.

a) Assembling component parts including suitable bedding compounds


b) All necessary plugging and brass screwing.
c) Joints to water services with straight or bent proprietary connection
d) Joints to waste soils or drain pipes with approved proprietary connections.
e) Cleaning off all protective wrappers and leaving ready for use.
f) Leaving taps and valves greased, clean and in full working order.
g) Builders work

3.a.3.11.6 It shall be the responsibility of the Contractor to do all the necessary co-ordination work and
obtaining of the necessary water supply/sewer connections from the relevant authorities unless otherwise
measured separately.

3.a.3.12 ELECTRICAL INSTALLATION

3.a.3.12.1 The rates in general shall include for the following:

a) All cutting, short lengths and small quantities


b) All considerations arising from the specification
c) Fixing conduits and ducts.
d) Pipe sleeves through walls
e) Assembling component parts.
f) Cleaning off protective wrappers and leaving ready for use.
g) Leaving all equipment etc, clean and in full working order.
h) Draw wires in empty conduits
i) Supply, installing, testing and commissioning of the system for power and lighting complete to working
order and to the entire satisfaction of the Engineer and the relevant authorities unless otherwise measured
separately.
j) It shall be the responsibility of the Contractor to do all the necessary co-ordination work and obtaining of
the electrical power connections from the relevant authorities unless otherwise measured separately.
k) Laying and jointing of conduits
l) Cutting, trimming, dressing, connection cables, cutting holes and chases in brick/concrete works and
connecting cable with accessories.
m) chasing in walls, columns and slabs for conduits
n) Covering up and making good the surfaces
o) Fixing conduits underside of soffits and surfaces of walls by means of brackets
p) Drilling holes of required sizes in walls and slabs for through conduits and such other items of works
necessary to be done for a complete installation.

3.a.3.12.2 Rates for cables and ducts in trenches shall include concrete or granular bed & surrounds caution
tapes, cover tiles etc, as required by the Specification.

3.a.3.12.3 Rates for mechanical and electrical equipment, plant or the like to include for all necessary
connections to power supply.

3.a.3.12.4 All materials, equipment, wiring and workmanship shall confirm to local codes and specifications,
BS standards/ latest I.E.E. regulations and complying with Ceylon Electricity Board Requirements

3.a.3.12.5 Rates for point wiring shall include for all cables, switches (1 way or 2 ways as necessary), junction
boxes, conduits, switch boxes, clips, earth cables, draw wires, wiring accessories, Screws, nails, hardware,
fixing and insulating materials, cutting holes, chases make good the same in all trades, holders, ceiling boxes,
flexible codes and other wiring accessories required up to the final fixing point wherever necessary.

3.a.3.13 FLOOR & WALL FINISHES

3.a.3.13.1 General:

The rates for all work in this section shall include for the following;

a) Preparation of surfaces for proper bonding


b) Straight, raking, curved and circular cutting and all consequent wastage.
c) All setting out temporary rules, screeds, templates and supports.
d) Curing and cleaning off/down upon completion
e) Spacers, cover guards etc. to tiling or the like
f) All labours and making good around pipes, ducting and fittings and the like
g) Brushing and cleaning off and damping down all backgrounds
h) Square and rounded edges, floor and ceiling junctions, making good to frames and the like.
i) Dubbing out as necessary to take up tolerances in the structure and cambers in floors and the like
j) All feature grooves or the like.
k) All construction joints including sealant.
l) Cutting and grinding edges of tiles/ granite as necessary.
m) Providing grooves between tiles which are not less than 2 mm using tile spacers.
n) Using tile adhesives as directed by the Engineer.

3.a.3.13.2 Floor finishes:

a) Ceramic or clay tiles are deemed to include rounded edges tiles and special tiles if required by the
Engineer.
b) Rate for floor tiling shall include for laying to pattern and design
c) Rate shall include for preparation of sample panels of different finishes for approval
d) Item is deemed to include laying tiles on curb and edges.
e) Rate shall include for forming grooves and extra labour and materials on expansion Joints.
f) Item is deemed to include curing, cleaning on completion and protection
g) Item for finishes to steps shall include for forming nosing.

3.a.3.13.3 Wall Finishes:

a) Rate for in-situ finishes shall include for;


1. Providing angle beads, end beads and wire mesh on different surfaces as directed by the
Engineer
2. Providing grooves on surfaces between different surfaces as directed by the Engineer
3. Builders works in connection with services

b) Item for plastering to walls is deemed to include door/ window reveals and returns
c) Plastering to columns associated with walls shall be measured as plastering to walls
d) Plastering to beams associated with walls shall be measured as plastering to walls
e) Item is deemed to include finishes to rebates, grooves, chamfers, external and internal splays and nibs
unless measured separately.
f) Rates shall include for all temporary rules, screeds, grounds etc., for raking out joints of new brickwork or
hacking new concrete for key. Internal and coved angles, joints between different surfaces and between new
and old plastering, arises, quirks, inter sections between curved or irregular surfaces etc., and all making
good around pipes, sanitary fittings and similar fixtures.
g) Rate for plasterwork shall include for expanded metal or the like in areas of different modes of
construction. (eg. Block work and concrete work.)
h) Leaving soffits of slab of even finish to receive ceiling finishes.
i) Rates shall include for making adequate space for drawing of all conduits of walls and partitions.
k) Fair joints, outlets, working over and around obstructions, pipes and the like into recesses and shaped
inserts, forming shallow channels, bonding agents where included with the work, dividing strips where
applicable, all extra work necessary for patterned work, are deemed to include where applicable with the
items.
l) Treads and risers are deemed to include fair edges, internal and external angles.
j) Strings and aprons are deemed to include ends, angles, ramped and wreathed covers.
k) Skirting, kerbs and edges of floors are deemed to include fair edges, rounded edges, covered junctions,
angles and the like.

Rates for plaster works shall include for;

a) Repair all plaster cracks as directed by the Engineer with application of galvanized wire mesh
where appropriate.
b) Prior to repairs to any plasterwork, the area to be re-plastered must be isolated from the rest of
the plasterwork, to prevent cracks propagating in to adjacent areas, by cutting a groove in the plaster up to
the brickwork.
c) All materials removed from buildings to be protected carefully from element until takeover by the
Employer.
3.a.3.14 PAINTING

3.a.3.14.1 All paint materials shall be best quality and shall be products of recognized manufacturer
approved by the Engineer.

3.a.3.14.2 All surfaces to be painted shall be prepared as directed and the prepared surfaces shall be
approved by the Engineer before painting.

3.a.3.14.3 The rates for painting shall include for the following:

a) Preparation of surfaces which shall include for surface filling.


b) Smoothing, knotting, stopping etc.
c) Protection of floors and fittings, removing and replacing door and window fittings if required and cleaning
upon completion and the like.
d) Sample painting in different colour and on different surfaces as required by the Engineer
e) Work on "Woodwork" shall include both soft wood and hardwood.
f) Unless of a differing specification, work shall be deemed to cover internal or external painting.
g) Work to curved surfaces.
f) Preparation of surfaces cleaning down, smoothing knotting, stopping etc.
g) removing existing paintwork from wall and timber (door window frames, sashes, architraves, skirting,
cornices etc.) surfaces cleaning and preparing the surface to receive the paint.
h) Painting in metal work is deemed to include work to attached holder bats, fastenings and the like.
i) Work to services is deemed to include work to saddles, pipe hooks, holder bats, conduit box and the like.
j) Painting door and window reveals unless otherwise measured separately.
Governance for Local Economic Development Programme

BOQ - GRAND SUMMARY SHEET

CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS


PROJECT TITLE MPCS OUTLET AND SPACE FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM
NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

PROJECT NO JAF/NLDP III/87392/002/01&02

PROJECT LOCATION PALAIVEEMANKAMAM NORTH, TELLIPALAI

DISTRICT JAFFNA

AMOUNT WITHOUT
ITEM # DESCRIPTION PRO.SUM(Rs)
PRO.SUM -(Rs)

1 PROVISIONAL SUM FOR PRELIMINARIES

2 CONSTRUCTION OF VILLAGE SECRETARIAT 50,000.00

3 CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT 15,000.00

4 RENOVATION OF MPCS BUILDING AS MPCS OUTLET 50,000.00

5 CONSTRUCTION OF TOILET FOR MPCS BUILDING 15,000.00

Sub Total 1 (Total of 2 to 5 Amount without Pro.Sum)

Discounted Amount ……% for Sub Total 1 (if any)

Sub Total 2 [(1+Pro.sums of 2 to 5+Sub Total 1) - Discount]

5% of Physical Contingencies of Sub Total 2

Bid Amount (Sub Total 2+ contingencies)

Bid Amount in Words (Excluding VAT) : SLRs. …………………………………..……………………………

………………………………………………………………………………………………………………………..

VAT Registration No (if available) …………………………………………………………………………………………………….

Signature and seal :…………………………………………………………………………………………………

Name of Bidder :……………………………………………………………………………………………………

Address :………………………………………………………………………………………………………………

Date :…………………………………………
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 01- PRELIMINARIES
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
PRELIMINARIES

All the Bidders are requested to refer "Pricing


Preamble and notes below" and works items of this
Bills of Quantities shall be priced to fulfill the
requirements there-in. Also see that no page or
items are missing prior to pricing the bill of
quantities.
The Bidder is advised to refer to the General Notes, Note
Pricing Preambles, Drawings, Specifications,
Conditions of Contract, Particular Conditions of
Contract and other relevant documents prior to pricing
the following items.
The Bidder is advised to visit the site of the proposed Note
work, as it is his responsibility to ascertain the
conditions governing access to the site, and external
working space, storage area etc.
A list of typical general items are given below. Note
However, the Bidder is requested to price only those
items that may affect this Contract.
Exsisting roads & culverts cannot take the passage of Note
heavy vehicle or such in adquiate areas to be
strenghten by the successful bidder, before make use
of such areas, roads and approches.
Any other preliminary items not listed below but Note
deemed necessary for the successful execution of
the project shall be included in the tender rates, as
no claims for extra payments for such, would be
entertained.
All temporary works shall be dismantled and cleared Note
away from the site on completion of the work.
Contractor shall provide helmets, gloves, safety masks, Note
dusk masks, eye goggles, boots etc. for the workmen.

Contractor shall provide safety boards, signs and safety Note


ribbons (plastic yellow and black stripes) to be erected
at site.
Contractor shall take special care for safety of school Note
children, staff and public during transportation of
materials and implementation of the contract.
Mechanical plant and equipment which emits excessive Note
noise, water, smoke, fumes, or obnoxious liquids, gases
etc., will not be allowed to be used on the site. If the
use of such machinery becomes necessary, the
Contractor is expected to obtain prior approval.

No work in any trade shall be carried out in such a Note


manner as to cause any nuisance to adjacent owners or
the public.
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 01- PRELIMINARIES
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
The Engineer has the final decision as and when he Note
deems it necessary for the Contractor to take
precautions, maintain or repair such plant and
equipment or order their removal from the site.
The contractor shall be responsible for any loss or Note
damage to the works, existing structures, adjoining
structures and unfixed materials.
The Contractor shall be responsible for necessary Note
lighting, watchman and other suitable measures during
construction until handing over
Contractor shall be responsible for erection, shifting Note
and maintaining of necessary protective netting,
fencing, hording, screens at site and other precautions
to the required standard and satisfaction of the
Engineer.
1.01 Provisional Sum for site office for consultant - staff Allow Pro. Sum 25,000.00
including necessary furniture, electricity, water &
sanitary facilities to the approval of Engineer.
1.02 Provisional Sum for providing and maintaining a first Allow Pro. Sum 3,000.00
aid box and regular supply of medicine, linen etc.

1.03 Provisional Sum for setting out of Works in Allow Pro. Sum 3,500.00
accordance with drawings and other written
information given by the Engineer.
1.04 Provisional Sum for all cost in connection with Allow Pro. Sum 5,000.00
preparing samples for testing, making arrangemnts for
testing of mataerials, goods etc., as stipulated in the
specification, obtaining test reports and submitting the
same to the Engineer.
1.05 Provisional Sum for provision of 3 sets of (hard copies Allow Pro. Sum 3,000.00
and soft copies) As-Built drawings & maintanace
manuals of all services for Enginner's approval.

1.06 Provisional Sum for providing all necessary safety Allow Pro. Sum 4,000.00
measures to workmen at site such as helmets, gloves,
safety masks, dusk masks, eye goggles, boots etc.
conforming to the latest industrial safety regulations
and as derected by the Engineer.
1.07 Provisional Sum for providing and maintaining of Allow Pro. Sum 20,000.00
Name Board (Two numbers )of Size 2/ 1.2m x 0.9 m,
as directed and approved by the engineer. Rate shall
include for erection and fixing to the earth firmly on to
the concrete base.
1.08 Allow Sum for providing a Performance Security Allow Sum
1.09 Allow Sum for Insurance of Completed works. Allow Sum
1.10 Allow Sum for Insurance against accidentsand injury Allow Sum
to Contractor's personnel as per the contract
TOTAL FOR BILL NO.01-PRELIMINARIES CARRIED
SLRs.
TO GRAND SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND
SPACE FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN
JAFFNA
BILLS OF QUANTITIES

SUMMARY OF BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT

AMOUNT
ITEM # DESCRIPTION
(SLRs.)
A Excavation and Earth Work

B Concrete Work

C Masonry Work

D Waterproofing

E Structural metal work

F Metal Works

G Ceiling Works

H Roofer and Roof Plumbing

I Floor, Wall and Ceiling Finishes

J Paintor & Decorator

K Plumbing and Sanitary Installation

L Electrical Installation

M External work

TOTAL FOR BILL NO.02 CARRIED TO GRAND SUMMARY


CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
A EXCAVATION AND EARTH WORK

Rates for excavation shall include for :


All necessary shoring, strutting, etc. and removal after
completion of work.
Stabilisation of excavated surfaces, if required.
All working space required, including for planking, strutting,
formwork etc.

Bulking after excavation and disposal of excavated material


as directed.
Backfilling with approved material to required levels and
surfaces, consolidating and ramming by an approved method
for over excavation.
Dewatering, if required.
Measurement for payment for excavation shall be for the net
contact volumes upto the concrete surface.

A.01 Allow Lump Sum for Clearing site, bushes, shrubs under Item 1.00
growth hedges and up rooting trees

A.02 Excavating to reduce level average depth of 150mm m2 172.00

A.03 Excavation for Wall and Column foundations in any material m3 10.50
except rock requiring blasting, depth not exceeding 1500mm
from the existing Ground level.

A.04 Excavation for Wall and Column foundations in Hard rock 3 7.00
m
requiring blasting, depth not exceeding 1500mm from the
existing Ground level.
A.05 Filling under floors and under Steps with Approved 3 58.00
m
imported hard earth filling including levelling, watering and
compacting in 150mm layers with 98% compaction.
(Measured compacted volume)
A.06 Anti - termite treatment which shall cover excavated m2 160.00
trenches, pits, etc. and the ground covered by floor slabs,
foundation &walls and 2m beyond the building perimeter.
Work shall be carried out by a reputed Pest control Company
approved by the Engineer. Particulars of chemicals used and
their concentration shall be forwarded to the Engineer for
approval. The Contractor shall furnish a joint guarantee
binding Specialist Sub-contractor and the Contractor as to
the effectiveness of the Anti-termite treatment for a
minimum period of 10 years after completion and cost shall
include for precautionary measures against chemicals being
infiltrated into outside area.Area Measured shall be Plinth
area of the Building.

SUB TOTAL FOR EXCAVATION AND EARTH WORK


SLRs.
CARRIED TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT

B CONCRETE WORK
Unless otherwise stated all concrete shall be of grade as per Note
Specifications
Rates for concrete shall include for construction joints, Note
expansion joints or contraction joints as necessary.
Concrete shall be measured as the net area/volume, as Note
shown on the drawings.
Rate for concrete shall include for :
supply, handling at site, depositing, compacting, vibrating,
curing and making good after removal of formwork.
preparation of surfaces, roughening/chipping to the
approval of the Engineer.
providing water stops at temporary construction joints, if Note
necessary.
Reinforcement and Formwork paid separately unless Note
specified in the Item.
Rate for formwork shall include for all necessary boarding, Note
supports, erecting, framing, cutting angles, cleaning, apply
approved foam oil, wetting before placing concrete, removal
etc.
Formwork is measured as the net contact surface Note
measurement between formwork and concrete.
All reinforcement shall be as per relevant British Standards Note
having minimum characteristic strength of 460 N/mm2 for
2
ribbed tor steel and 250 N/mm for mild steel.
Rate for reinforcement shall include for supplying, cleaning, Note
cutting, bending, fabricating, binding, placing in position,
binding wires, ties, supporting bars, spaces, chairs, wastage
etc.
1 :3 :6 (40mm) Volumed Batched Concrete
B.01 75mm thick Screed concrete under Wall & Column 2 34.00
m
foundation.
1 :2 1/2 :5 (25mm) Volumed Batched Concrete
B.02 75mm thick, mass concrete in floors and Steps in Building 2 149.00
m
and Ramp
1 :2 :4 (20mm) Volumed Batched Concrete
B.03 Reinforced concrete in Columns Foundation 3 1.00
m
B.04 Reinforced concrete in Columns 3 2.00
m
B.05 - do - Plinth Level Beams 3 1.75
m
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
Formwork

B.06 Sides of Colunms Footings 2 6.00


m
B.07 Sides of Colunms 2 26.00
m
B.08 - do - Plinth Level Beams 2 10.50
m
Permanent PVC pipe form work
B.09 Sides of Colunms, circular, Using 150mm Diameter type 400 m 15.00
PVC pipe
High yield Steel reinforcement & Mild Steel
reinforcement
B.10 In Column Footing kg 50.00
B.11 In Columns kg 252.00
B.12 In Plinth Level Beams kg 145.00
B.13 Construction of reinforced concrete (20 N/mm -20mm) 2 m 35.00
lintel of size 125 mm x 150mm. Rate to including for form
work & reinforcment ( 2 Y12 bars) in Building.
SUB TOTAL FOR CONCRETE WORK CARRIED TO
SLRs.
SUMMARY
C MASONRY WORK
Notes :
Rate shall include to,
1. All rough and fair cutting, plumbing angles, normal
straight cutting, forming rebated reveals and raking out
joints
2. for plastering.
Forming rough and fair groves, throats, mortises,
chases, rebates and holes, stops and miters.
3. Supplying & Fixing

Stone Work
Random Rubble Masonry Work
C.01 Random Rubble( 150 mm-225 mm) Masonry work in 1:5 3 15.00
m
Cement sand mortar in Wall Foundation of Building and in
Disable Ramp

Block Work
All cement and sand concrete blocks shall comply with BS
6073.
Characteristic strength of block work shall be 2.5 N/mm2
Mortar used for block work/ brick work shall be 1:5 cement
and sand mixture unless otherwise specified.

125mm Cement Block Work


C.02 125mm thick block work in 1:5 cement sand mortar for 2 135.00
m
walls in Building.

SUB TOTAL FOR MASONRY WORK CARRIED TO


SLRs.
SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT

D WATER PROOFING
Damp Proofing
D.01 Damp proof membrane to horizontal surfaces of floors out of 2 116.00
m
1000 gauge polythene.

D.02 20mm thick 1:2 cement : sand DPC and finished with two 2 6.00
m
coats of hot tar blinded with coarse sand.

SUB TOTAL FOR WATER PROOFING CARRIED TO


SUMMARY

E STRUCTURAL METAL WORK

Notes for Steel works


All steel used in the work shall comply with the relevant
British Standards & to the specifications.

All steel shall be new & each member shall be free from any
built- weld or other forms of splice for the full length
between joints shown in or indicated in the drawings unless
such splice shall have been shown in the approved drawings.

The contractor shall submit the specification for the steel


which he proposed to use and obtain prior approval from
the Engineer before commencement of ordering of steel and
fabrication.

Drawings
Before any steel work is fabricated the contractor shall
obtain the Engineer's approval of the proposed details of
fabrications. For this purpose, two copies of each drawings
shall be submitted to the Engineer not less than 14 days
before commencement of fabrication.
Inspections
All steel work shall be subjected for inspection by the
Engineer. The steel works shall not be moved from the place
of fabrication nor primed or painted until the approval of the
Engineer has been obtained for the fabrication of steel work.

Welding
No welding shall be done until approval of the prepared
surface has been obtained. All welding shall be carried out
under the supervision of qualified persons.
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT

Base plate, Sole plate, gussets plate, splice etc. have not been
measured separately but the weights of such attachments
have been included in weight of respective items indicated in
item description.

Refer drawings for fabrication and fixing details of trusses,


beams, purling etc.

Trusses , Roof Frames, Beams & Columns


Structural steel should be of grade 43 ( Yield strength 275
2)
N/mm in compliance with BS 4360

Rates to include for the cost for scaffoldings

Rate shall include for all necessary cuttings, drillings,


bolting, reverting, welding, grinding, delivering, unloading,
hoisting, erecting and fixing in position, leveling, plumbing
and getting approval of all shop drawings.

Rate shall include for preparation and painting two coats of


anticorrosive and two coats of Enamel Painting. For GI Pipes
work One coat of Zinc Primer and two coats of Enamel
Painting shall be included in Rates.

Trusses & Roof Frames


Supplying, fabricating and fixing of steel trusses with
necessary accessories. Rate to include for base plates, sole
plates, cleats, rivets, bolts, nuts and washers.

E.01 Truss type T1 of Span 6.8m (Approx weight of Truss 215 Nr 2.00
Kg) as shown in Drawing made out of Equal Anle Iron, fixed
to Column.

E.02 Truss type T2 of Span 4.5m as shown in Drawing made out Nr 4.00
of 40mm GI heavy duty pipe for bottom and top member and
internal 25mm GI heavy duty pipe in diagonally , fixed to
Column and wall as per detail drawings- Rate to include for
bolts and nuts and preparation and painting two coats of
anticorrosive.and one coat of GI primer

Roof Purlins
E.03 Supplying and fixing of High tensile steel C7520 m 75.00
(75x50x15,2mm thickness) lipped channel purlins for Roof
with all necessary accessories. Rate to include for bolts and
nuts and preparation and painting two coats of
anticorrosive.

SUB TOTAL FOR STRUCTURAL METAL WORK CARRIED


SLRs.
TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
F METAL WORKS

Aluminium Works
Notes:
All sections shall be extruded from AA 6063 aluminum alloy
and sections shall be designed to give a rebated internal and
external faces
Aluminum sections for mullions, frames, transoms, heads
and the sills and the other members should strictly comply
with the requirements laid down in the following British
Standard

B.S. 1161 of 1972 – Specification for aluminum alloy sections


for structural purposes

B.S. 1470 of 1972 (Amended in 1987) – Wrought aluminum


and aluminum alloys plate, sheet and strip

B.S. 1474 of 1972 – Wrought aluminum and aluminum alloys


for general engineering Purpose and external architectural
application bars, extruded, down tubes and sections

Powder coated Aluminium sections where ever specified


shall be film thickness of 60-80 micron,

The Contractor shall refer all relevant drawings and


specification prior to pricing and it shall be his responsibility
to complete the said works to the entire satisfaction of the
Engineer.

All dimensions shown on the drawings shall be verified by


actual site measurement before fabrication and installation.
Any cutting to enlarge the size of opening and any cement
mortar filleting behind frames required after installation
shall be executed by the contractor at his own expense.

Glass panels in windows shall be body frosted/clear float


glass of minimum thickness 5 mm unless otherwise stated.

Glass panels in doors shall be body frosted/clear float glass


of minimum thickness 6 mm unless otherwise stated.

The Contractor shall submit detailed shop drawings and


fabricated samples of typical units of each type for the
approval of the Engineer, 14 days prior to fabrication.

Rate shall include for supplying, fabrication and installation.

Rates for doors and windows shall include for all necessary
ironmongery including stainless steel hinges, locks, Handles,
Heavy Duty Door Closers etc.
Rate for windows shall include for provision of heavy duty
stainless steel friction hinges and die-cast Natural Anodized
Aluminium fasteners.
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
Rates shall include for approved weather strip,
mastic/silicon, sealant, pointing, caulking, jointing, backing,
etc., as specified.
Infilled panels for Aluminium Door sash & Partition panels
shall be colour coated Aluminium composite Panels
Rate for handrail / guardrail shall include for necessary
welding, cutting, embedding, anchoring etc., as per detail
drawings.
Rates for all metal works shall include for necessary builders
work.
Doors
F.01 Supplying, fabricating and fixing Door type D1, 1200mm x Nr 1.00
2100 mm over all size Aluminium framed, infilled panel &
glazed double sash swing Door with all necessary
accessories.
F.02 Supplying, fabricating and fixing Door type D2, 900mm x Nr 4.00
2100 mm over all size Aluminium framed, infilled panel &
glazed single sash swing Door with door closer and all
necessary accessories.
Windows
F.03 Supplying, fabricating and fixing Window type W1, 1200mm Nr 5.00
x 1200mm over all size Aluminium framed, Glazed sash
Castement window with all necessary accessories

Alumnium Partition
F.04 Glazed Aluminium Partition on suitable Aluminium framed m2 60.00
sections with Glazed & PVC coated/glading
AluminiumPanels including all necessary fittings.

Steel Works -
Half Door
F.05 Supply and fixing 1200x900mm size Steel half door with all Nr 2.00
necessary accessories. .Rate shall include one coats of
anticorrosive paint and two coat of Enamel . As per detail
drawing

Window Safty Grill


F.06 Supply and Fixing Steel Grill,as shown in drawing Consisting m2 7.50
of 16mm x6mm flat iron frame work and 12mm x 6mm flat
iron ornamental work. Rate to include one coats of
anticorrosive paint and two coat of Enamel paint to grill
work and frame work.
Hand Rail
F.07 Supply and fix Guard rail comprising of 50mm diameter GI m 6.00
top rail, 900mm high 25mm diameter GI vertical members at
450mm intervals for uprights ( balusters) fixed on Ramp
Floor and 25mm diameter horizontal members at 300 mm
spacing fixed to balusters .Rate shall include 2 coats of
anticorrosive paint and one coat of Enamel

SUB TOTAL FOR METAL WORKS CARRIED TO SUMMARY SLRs.


CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT

G CEILINGS
Cement Fibre Ceiling
G.01 Supplying and installation of 4.5mm think Cement Fibre 2 70.00
m
ceiling fixed with necessary timber frame work (50mm x
100mm joists and 50mm x 50mm bearers at 600mm c/c) of
approved quality fixed with 40mm x 12mm timber beedings
of 40mm x 40mm timber cove mouldings of approved
quality with necessary screws and nail. Rate shall include for
applying two coats of wood preservative to Timber frame
work and One primer coat two coats of Fungus Resistant
emulsion paint to ceiling and two coats of enamel paint to
beedings mouldings.

SUB TOTAL FOR CEILING CARRIED TO SUMMARY

H ROOFER AND ROOF PLUMBING


Roof Covering
Tile Roofing
H.01 Supplying and placing of Calicut pattern Tile roofing laid on m2 117.00
timber roof frame work consists of 50×100mm rafters at
450mm spacing ,50 x25mm reepers at 300mm spacing and
at both eaves side spacing interval is 150mm shown in
drawing,50×175 ridge plates, 50 x 175 Hip Rafters , 50 x 175
Valley Rafters, 100mm x 100mm Centre posts, 100mm
x200mm & 75x150mm horizontal Beams and 100x75mm
wall plate as shown in drawing . Timber shall be imported
Hard wood, Red/ Yellow balaw or equvalent approved by the
Engineer and treated well with two coats of approved quality
wood preservatives. Rate shall include for necessary screws,
nails and fittings.

H.02 Supplying and fixing of Calicut pattern Ridge tiles jointed m 12.00
and bedded in 1:1:4 cement lime and sand mortar coloured
to match tiles.

Metal Roofing
Zn/Al alloy coated steel Roofing sheet steel minimum tensile
strength should be 550 N/mm2 and profile should be
approved by the Engineer.Rate shall include for Supplying
and fixing 0.47mm thick Zn/Al alloy coated colour bonded
steel roofing ridge/Hip to match to roof covering

H.03 Supplying and fixing of 0.47mm thick Corrugated Zn/Al m2 75.00


alloy coated colour bonded with 3mm thick 3 way reinforced
double side aluminum foil bonded sheet steel roofing on
steel lipped channel with necessary screws & hooks (Steel
lipped channel paid separately.)
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT

Roof Heat Proofing


H.04 Supplying and fixing 50mm x 50mm gauge 10 GI Wire Net 2 72.00
m
to Aluminum Foil welded mesh to the purlin. Rate shall
include one coat of Anty crossive and two coat of enamel
approved colour painting

H.05 Supplying and fixing of 20mm thick, 225mm timber valance m 44.00
& Barge Fascia board using brass screws and complete with
one coat of primer and two coat of enamel approved colour
painting

H.06 Supplying and fixing of 470mm wide 0.4 mm thick Zn/Al m 16.50
alloy coated color bonded steel flashing with 120mm
turned up long and top edge tucked well into wall in cement
lime mortar.
Roof Plumbing
H.07 Supplying and fixing 0.4 mm thick Zinc aluminium alloy m 25.00
coated colour bonded box type eave gutters of size 130 x
160mm of approved pattern and colour including end caps,
running joints with including all necessary fittings.

H.08 Supplying and fixing 0.4 mm thick Zinc aluminium alloy m 18.00
coated colour bonded down pipes of size 100mm x 100mm
of approved pattern and colour with brackets and brass
screws with wooden plugs including all necessary molded
fittings

SUB TOTAL FOR ROOFER AND ROOF PLUMBING CARRIED


SLRs.
TO SUMMARY

I FLOOR, WALL & CEILING FINISHES


Rates for floor finishes shall include for temporary rules,
screeds, ground etc., all normal cutting arises, rounded
angles and the like, bedding, pointing, forming joints making
good between different surfaces, around pipes, sanitary
fittings and other fixtures and cleaning down upon
completion.
All floor and wall tiles tiles shall be of approved quality (
Lanka Tiles/ Rocell Brands) and colour. Tile samples shall be
provided for approval by the Engineer/Architect prior to
purchase of materials.
Rates for plaster work shall include for reinforcing joints
between different types of construction material (e.g. block
work/ brickwork and concrete work) with 150mm wide
galvanized steel mesh as directed by the Engineer.Rate shall
include for Reveals.
Rates for soffit finishes shall include for preparation of
surfaces, cleaning down, smoothing, knotting, stopping, etc.,
protection of floors and fittings, removing and replacing
door and window fittings, if required, and cleaning upon
completion.
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
Floor Finishes
Rendering
I.01 25mm thick, 1:2 cement sand, coloured rendering m2 153.00

Wall Finishes
External Faces
Plastering
I.02 15mm thick 1:3 cement sand plaster finished smooth with m2 25.00
approved coloured cement floating to plinths.

I.03 15mm thick 1:3 cement sand plaster finished semi rough 2 96.00
m
with to walls, Columns and Sides of Beams & Lintols in
Building

Internal Work
Plastering
I.04 15mm thick 1:3 cement sand plaster finished smooth to m2 160.00
internal faces of walls, Columns and sides of Beams,tanks &
Lintel
SUB TOTAL FOR FLOOR, WALL & CEILING FINISHES
SLRs.
CARRIED TO SUMMARY

J PAINTER & DECORATOR


Note:
Rate shall include for preparation of surfaces, cleaning down,
smoothing, knotting, stopping, patching up cracks, etc.,
protection of floors and fittings, removing and replacing
door and window fittings, if required, and cleaning upon
completion.

All emulsion/ enamel/ weathershield paint shall be of


approved make CIC or equivalent approved by Engineer
Rate to include for the cost for the scaffoldings.

External Faces

J.01 Prepare & apply one alkaline resisting primer coat and two m2 96.00
coats of weather shield emulsion of approved colour and
quality to semi-rough rendered surfaces of walls, Columns
and Sides of Lintols. (Rate shall include for reveals)

Internal Faces
Walls
J.02 Prepare and apply one primer coat and two coats of Fungus m2 160.00
Resistant emulsion of approved colour and quality to smooth
plastered surfaces to internal faces of walls,Columns, sides
of Lintel and column faces. (Rate shall include for reveals)

SUB TOTAL FOR PAINTER & DECORATOR CARRIED TO


SLRs.
SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT

K PLUMBING AND SANITARY INSTALLATION

Unplasticized polyvinyl chloride (uPVC) pipes shall be used Note


in the plumbing installation and they must confirm in every
respect to the requirements of the SLS 147 of 1989 & 1972
or BS 4514.

All fittings and pipe specials used in the plumbing Note


installation shall be suitable and compatible with all respects
to the pipe line to which fittings and specials are fixed.

All sanitary fittings & fixtures shall be American Standards or Note


equivalent.

Rates for plumbing work shall include for:-

(a) Complying with the relevant Sri Lankan, British


or any other standard as given under the
specifications and with the regulations of the Local
Authority and or any other relevant authorities.
(b) Cutting and waste of pipes etc., and joining
pipes.
(c) All specials such as elbows, bends, tees,
junctions, plugs, reducers and similar pipe fittings
except for valves which will be measured
separately.
(d) Connecting pipes to sanitary fixtures and
appliances.
(e) Casing to brick walls etc. and making good all works
disturbed.
(f) Necessary screws, nails sockets, connection
back nuts standard pipe fixing or supporting clips,
saddles, brackets, holder bats, straps etc.
(g) Connecting different types of pipes.
(h) Testing and disinfection after completion.
(i) Submitting shop drawings where necessary.
(j) Excavation, backfilling, disposal of surplus soil Note

Rates for sanitary fittings shall include for:-


(a) Fittings such as taps, waste water outlet,
internal overflows etc. and supporting brackets,
incidental materials for fixing.
(b) Assembling, jointing together fixing components
parts, and jointing to pipes including necessary
coupling and for leaving perfectly clean and in
perfect working order on completion.
(c) Jointing and connecting pipes to sanitary fittings.
(d) Testing and commissioning of the installation.
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
(e) Making good the work disturbed.
(f) Submitting samples for the approval of the
Engineer.
(g) Protecting the works. Note

Rates for drainage work shall include for :-


(a) Laying of pipes to falls.
(b) Excavation, backfilling, disposal of surplus soil
(c) All pipe specials such as bends, junctions,
elbows, tees, "Y" junctions, reducers, inspection openings, stop ends, etc.
(d) Connection to sides of manholes etc.
(e) Providing sleeves etc., when pipes pass through
walls, foundations etc.
(f) Giving notices, obtaining permits, paying fees,
fixing, testing and commissioning etc. Note

Water Supply, Wastewater & Drainage Connection

Type 1000 Pipes for Cold Water Supply


K.01 20mm dia. m 8.00

K.02 25mm dia. m 20.00

K.03 40mm dia. m 25.00

K.04 50mm dia. m 55.00

Valves for Water Supply Lines


Supplying and fixing of approved quality Brass stop valves
/Ball Valves including all necessary fixtures.Valves shall be
of Pegler or equivalent Brands.

K.05 25 mm diameter valve Nr 2.00

K.06 40 mm diameter valve Nr 2.00

K.07 50 mm diameter valve Nr 1.00

K.08 Supplying and fixing Electric Water Pump and Construction Nr 1.00
of Pump Room as per Drawing. Pump with motor of 1.5 HP
(Jinasena or equvalent), 1 1/2" x 1 1/4" , single phase on
cement concrete bed 600 x 450 x 150mm in 1:2:4 (20mm)
mix with 04 Nos 3/8" x 6" rag bolt & nuts, rendered in
cement mortar 1:2 including foot valve & starter switch
complete in working order.

K.09 Supplying and installation of 1000 litre capacity plastishell Nr 1.00


overhead water tank with Steel Framework and 6m high
Steel Tower as per Drawings.
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT

Type 600 uPVC pipe for Waste Water Lines

K.10 50 mm diameter m 10.00

K.11 63 mm diameter m 12.00

Valves for Waste Water Outlet


Supplying and fixing of approved quality Brass stop valves
including all necessary fixtures.Valves shall be of Pegler or
equivalent Brands.

K.12 50 mm diameter valve Nr 1.00

Waste Water Catch Pits


K.13 Supplying all material and construct water sealed catch pits Nr 1.00
(Average size 300 x 300 x 400 mm internally). Rate included
for excavation & backfilling, screed concreting, formwork,
reinforcement @ 150 c/c, 75mm thick concrete base &
125mm block walls, internal plastering, precast concrete
cover slab with lifting handles, etc.

Waste Water Manholes


K.14 Supplying all material and construct Intercepter manholes Nr 1.00
(Average size 450 x 450 x 600 mm internally). Rate included
for excavation & backfilling, screed concreting, formwork,
reinforcement @ 150 c/c, 150mm thick concrete base &
walls, benching, internal plastering, precast concrete cover
slab with lifting handles, etc.

SUB TOTAL FOR PLUMBING AND SANITARY


SLRs.
INSTALLATION CARRIED TO SUMMARY

L ELECTRICAL INSTALLATION
Rates in Bill of Quantities shall include all necessary
materials (Cables, conduits, PVC sunk box, bulbs, switches
etc.) and labour required to complete the electrical
installation to good working order.
Testing and commissioning of all the systems & electrical
installation is to be carried out and inspection report ( 02
sets) submitted according to the requirements of the power
supply by a Chartered Electrical Engineer.Rate shall be
include for Testing,commissionung and report submission.

Rate Shall include for submission of shop drawings and


submission of draft layouts, conduit layouts etc.for
Consultant's approval before commencing the installation
(03 sets)with Designing of Distribution board, Consumer
unit and line diagram designing by a Chartered Electrical
Engineer.
Rate Shall include for submission of As-built drawings on
completion of the contract (03 sets)
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
Electrical Items (MCB,RCCB etc.) should be of
European/Japanese origin or to the BS or equivalent and
items without an accredited agent in Sri Lanka shall not be
accepted. Guarantee cards(Fans etc.) should be provided
from accredited agent before installation.

All the quantities given here are approximated values and


Quantities may change with the actual installation at the site.

All types of fittings, materials, painting and finishes shall be


approved by the Engineer prior to installation.
All panel boards and consumer units should have wire
numbering and a laminated circuit diagram should be pasted
on the inside surface of the door.

Electrical Coduits, which are laid along Earth should be


securely protected by PVC conduits. Earth shall be backfilled
properly.

Electrical Coduits, which are laid along internal Roads should


be securely protected by PVC conduits. Cut road shall be
filled with mass concrete and making good to roads.

Single phase Consumer units

L.01 Supply and installation of wall mounted switch gear cubicle Nr 1.00
made
01 No.out of 2-pole
40A, polycarbonate
MCB 6kAenclosure to the approval of the
01 Nos. 40A 2-pole RCCB, 30mA sensitivity
7 - 9 No. 6-32A, 1-pole MCB 6kA
Earth Bar
All internal connections.
Equipment to be to the BS and European/Japanese make
L.02 Supply and Installation of service bracket 5'-0" long 2 1/2" x Nr 1.00
2 1/2" x 1/4" angle iron.

L.03 Provisional Sum for obtaining main power supply Allow Pro. Sum 20,000.00
connection from the Ceylon Electricity Board 6 including all
the correspondence and co-ordination work, builders work.
Etc.

L.04 Supply & installation of 32A single phase wiring to pump Nr 1.00
house . Rate to include for MCB, complete with pilot lamp to
working order as per electrical specification.

Cables
L.05 Provisional Sum for Suppling and Installation of Main Allow Pro. Sum 30,000.00
Cables from Energy Meter to MDB and MDB to Cosumer
Units
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
Fans
L.06 Supply & installation of 1400mm sweep ceiling fan Nr 5.00
(European/Japanese make), complete with regulator, fan
hook, extension rod & attachment - Guarantee cards should
be provided from accredited agent. Rate to include for wiring
(including supply of all material, earth wire & switch) of the
above ceiling fans using approved type 1 mm2,
Cu/PVC/PVC cable & 2.5 mm2 earth wire drawn through
securely fixed concealed PVC conduits

Socket Outlets
L.07 Supply & installation of 15A shuttered switched single Nr 4.00
socket outlet to comply with BS 1363 . Rate to include for
Wiring (including supply of all material required ) of 15A
socket outlets using approved type 2.5mm2 Cu/PVC/PVC,
2C cable & 2.5mm2 earth cable drawn through securely fixed
concealed PVC conduit

L.08 Supply & installation of 5A shuttered switched socket Nr 5.00


outlet to comply with BS 1363.Rate to include for Wring
(including supply of 2.5 mm2 earth wire & all other material
required ) of above socket outlet using approved type
1.0mm2 Cu/PVC/PVC cable drawn through securely fixed
concealed PVC conduits

Light Fitting
Samples should be provided prior to the installtion for
electrical engineer's approval. Guarantee cards should be
provided for CFL bulbs.

L.09 Supply and installation of Pendent Type Lamp Fittings. Rate Nr 5.00
to include the cost of 24W CFL Spiral bulbs (warm white)
lamp.Rate to include for Wiring (including supply of all
materials) of the above light points using approved type PVC
insulated PVC sheathed 1 mm2 copper cable and 1mm2
Cu/PVC earth drawn through securely fixed concealed PVC
conduit

L.10 Supply and installation of Wall Mounted/ Bracket Lamp Nr 6.00


Fittings. Rate to include the cost of 20W approved type
bulbs. Rate to include for Wiring (including supply of all
materials) of the above light points using approved type PVC
insulated PVC sheathed 1 mm2 copper cable and 1mm2
Cu/PVC earth drawn through securely fixed concealed PVC
conduit
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES
BILL NO 02- CONSTRUCTION OF VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT

Main Earthing System


Supply and Installation of all required materials and cables
and connection to respective equipment to provide complete
system.
L.11 Supply and Installation of an earth electrode of minimum Nr 1.00
16mm dia. solid copper rod of length 1.2m or more with a
clamp connection to earth conductor. Earth resistance shall
be less than 10 Ohms tested on a dry day. An earth pit of size
300mm x 300mm x 200mm is to be prepared and covered
by concrete plate to protect the earth electrode.

SUB TOTAL FOR ELECTRICAL INSTALLATION CARRIED


SLRs.
TO SUMMARY
M EXTERNAL WORKS
Steel Gate
M.01 Supplying, fabricating and fixing of Gates of sized 4000mm nr 1.00
(wide) x 1650mm ( height) with made out of heavy duty
75x 50mm Hollow GI Box section and 25mm diameter G.I
pipes as shown in Drawings. . Rate to include for 2 Nos 300
x 300mm RCC pillars for 2.0 m height in 1:2:4 (3/4")
concrete 4Y12 reinforced and R6 at 150mm crs stirrups rate
include for Excavation base concrete footing R/F with Y10 @
200mm c/c both way and 16mm thick 1:4 plastering, 3 Nos
pintol and stirrups locking device barrel bolt etc. and 2 coats
of anticorrosive paint and 2 coats of enamel paint and 2
coats of painting to pillers as directed.
Chainlink Mesh Fence
M.02 Supplying and fixing of 1.80 m high (above Ground) gauge 8 m 88.00
PVC coated chainlink mesh on the fence posts. Rate to
include for 3 Nos, top.middle and bottom line wires,
stretcher bars and bolting bracket arrangement with cleats,
washers etcf including Casting, transport & erection of
intermediate (at 2.4 m intervals) , corner, end and strainer
RCC fence posts ( 100mm x 100mm at top & 150mm x
150mm at bottom ,Reinforced with 4 no R6 Mild steel with
High tensile wire stirrups spaced at 225mm . Rate to include
for excavation of pits and erection of fence posts along
boundary line with lower end buried in ground and
surround with grade 10 concrete .

SUB TOTAL FOR EXTERNAL WORKS CARRIED TO


SLRs
SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND
SPACE FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION
IN JAFFNA
BILLS OF QUANTITIES

SUMMARY OF BILL NO 03- CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT

AMOUNT
ITEM # DESCRIPTION
(SLRs.)
A Excavation and Earth Work

B Concrete Work

C Masonry Work

D Waterproofing

E Metal Works

F Roofer and Roof Plumbing

G Floor, Wall and Ceiling Finishes

H Paintor & Decorator

I Plumbing and Sanitary Installation

J Electrical Installation

TOTAL FOR BILL NO.03 CARRIED TO GRAND SUMMARY


CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 03- CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
A EXCAVATION AND EARTH WORK

Rates for excavation shall include for :


All necessary shoring, strutting, etc. and removal after completion
of work.
Stabilisation of excavated surfaces, if required.
All working space required, including for planking, strutting,
formwork etc.

Bulking after excavation and disposal of excavated material as


directed.
Backfilling with approved material to required levels and
surfaces, consolidating and ramming by an approved method for
over excavation.
Dewatering, if required.
Measurement for payment for excavation shall be for the net
contact volumes upto the concrete surface.

A.01 Allow Lump Sum for Clearing site, bushes, shrubs under growth Item 1.00
hedges and up rooting trees

A.02 Excavating to reduce level average depth of 150mm 2 12.00


m
A.03 Excavation for Wall and Column foundations in any material 3 2.50
m
except rock requiring blasting, depth not exceeding 1500mm
from the existing Ground level.
A.04 Filling under floors and under Steps with Approved imported 3 2.50
m
hard earth filling including levelling, watering and compacting in
150mm layers with 98% compaction. (Measured compacted
volume)

SUB TOTAL FOR EXCAVATION AND EARTH WORK CARRIED


SLRs.
TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 03- CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
B CONCRETE WORK
Unless otherwise stated all concrete shall be of grade as per Note
Specifications
Rates for concrete shall include for construction joints, expansion Note
joints or contraction joints as necessary.
Concrete shall be measured as the net area/volume, as shown on Note
the drawings.
Rate for concrete shall include for :
supply, handling at site, depositing, compacting, vibrating, curing
and making good after removal of formwork.
preparation of surfaces, roughening/chipping to the approval of
the Engineer.
providing water stops at temporary construction joints, if Note
necessary.
Reinforcement and Formwork paid separately unless specified in Note
the Item.
Rate for formwork shall include for all necessary boarding, Note
supports, erecting, framing, cutting angles, cleaning, apply
approved foam oil, wetting before placing concrete, removal etc.

Formwork is measured as the net contact surface measurement Note


between formwork and concrete.
All reinforcement shall be as per relevant British Standards Note
having minimum characteristic strength of 460 N/mm2 for
2
ribbed tor steel and 250 N/mm for mild steel.
Rate for reinforcement shall include for supplying, cleaning, Note
cutting, bending, fabricating, binding, placing in position, binding
wires, ties, supporting bars, spaces, chairs, wastage etc.

1 :3 :6 (40mm) Volumed Batched Concrete


B.01 75mm thick Screed concrete under Wall & Column foundation. m2 4.50

1 :2 1/2 :5 (25mm) Volumed Batched Concrete


B.02 75mm thick, mass concrete in floors and Steps in Building and 2 2.25
m
Ramp
B.03 Construction of reinforced concrete (20 N/mm2 -20mm) lintel of m 12.50
size 100 mm x 150mm. Rate to including for form work &
reinforcment ( 2 Y12 bars) in Building.

SUB TOTAL FOR CONCRETE WORK CARRIED TO SUMMARY SLRs.


CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 03- CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT

C MASONRY WORK
Notes :
Rate shall include to,
1. All rough and fair cutting, plumbing angles, normal straight
cutting, forming rebated reveals and raking out joints for
plastering.
2. Forming rough and fair groves, throats, mortises,
chases, rebates and holes, stops and miters.
3. Supplying & Fixing

Stone Work
Random Rubble Masonry Work
C.01 Random Rubble( 150 mm-225 mm) Masonry work in 1:5 Cement m3 4.00
sand mortar in Wall Foundation of Building and in Disable Ramp

Block Work
All cement and sand concrete blocks shall comply with BS 6073.

Characteristic strength of block work shall be 2.5 N/mm2


Mortar used for block work/ brick work shall be 1:5 cement and
sand mixture unless otherwise specified.

100mm Cement Block Work


C.02 100mm thick block work in 1:5 cement sand mortar for walls in m2 32.00
Building.

SUB TOTAL FOR MASONRY WORK CARRIED TO SUMMARY SLRs.


CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 03- CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
D WATER PROOFING

Damp Proofing
D.01 20mm thick 1:2 cement : sand DPC and finished with two coats of 2 4.50
m
hot tar blinded with coarse sand.
SUB TOTAL FOR WATER PROOFING CARRIED TO SUMMARY

E METAL WORKS
Aluminium Works
Notes:
All sections shall be extruded from AA 6063 aluminum alloy and
sections shall be designed to give a rebated internal and external
faces
Aluminum sections for mullions, frames, transoms, heads and the
sills and the other members should strictly comply with the
requirements laid down in the following British Standard

B.S. 1161 of 1972 – Specification for aluminum alloy sections for


structural purposes
B.S. 1470 of 1972 (Amended in 1987) – Wrought aluminum and
aluminum alloys plate, sheet and strip
B.S. 1474 of 1972 – Wrought aluminum and aluminum alloys for
general engineering Purpose and external architectural
application bars, extruded, down tubes and sections

Powder coated Aluminium sections where ever specified shall be


film thickness of 60-80 micron,
The Contractor shall refer all relevant drawings and specification
prior to pricing and it shall be his responsibility to complete the
said works to the entire satisfaction of the Engineer.

All dimensions shown on the drawings shall be verified by actual


site measurement before fabrication and installation. Any cutting
to enlarge the size of opening and any cement mortar filleting
behind frames required after installation shall be executed by the
contractor at his own expense.
Glass panels in windows shall be body frosted/clear float glass of
minimum thickness 5 mm unless otherwise stated.

Glass panels in doors shall be body frosted/clear float glass of


minimum thickness 6 mm unless otherwise stated.
The Contractor shall submit detailed shop drawings and
fabricated samples of typical units of each type for the approval
of the Engineer, 14 days prior to fabrication.
Rate shall include for supplying, fabrication and installation.

Rate for windows shall include for provision of heavy duty


stainless steel friction hinges and die-cast Natural Anodized
Aluminium fasteners.
Rates shall include for approved weather strip, mastic/silicon,
sealant, pointing, caulking, jointing, backing, etc., as specified.
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 03- CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
Infilled panels for Aluminium Door sash & Partition panels shall
be colour coated Aluminium composite Panels
Rate for handrail / guardrail shall include for necessary welding,
cutting, embedding, anchoring etc., as per detail drawings.

Rates for all metal works shall include for necessary builders
work.

Doors

E.01 Supplying, fabricating and fixing Door type D1, 1050mm x 2100 Nr 1.00
mm over all size Aluminium framed, gladding panel single sash
swing Door with handle and all necessary accessories.

E.02 Supplying, fabricating and fixing Door type D2, 750mm x 2100 Nr 1.00
mm over all size Aluminium framed, gladding panel single sash
swing Door with all necessary accessories.

SUB TOTAL FOR METAL WORKS CARRIED TO SUMMARY SLRs.


CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 03- CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
F ROOFER AND ROOF PLUMBING

Roof Covering

Metal Roofing
Zn/Al alloy coated steel Roofing sheet steel minimum tensile
strength should be 550 N/mm2 and profile should be approved by
the Engineer.Rate shall include for Supplying and fixing 0.47mm
thick Zn/Al alloy coated colour bonded steel roofing ridge/Hip to
match to roof covering
Wood preservative should be applied to timber frame work
F.01 Supplying and fixing of 0.47mm thick Corrugated Zn/Al alloy m2 15.00
coated colour bonded with 3mm thick 3 way reinforced double
side aluminum foil bonded sheet steel roofing laid on timber roof
frame work 100m x 50mm rafters max c/c 900mm and 50mm
x50mm beares max 1000 mm c/c for Toilet as shown in
Drawing rate shall include with timber frame work.Solignam to
be applied to all timber frames

F.02 Supplying and fixing of 20mm thick, 225mm timber valance & m 16.00
Barge Fascia board approved quality timber planks, using brass
screws and complete with one coat of primer and two coat of
enamel painting

SUB TOTAL FOR ROOFER AND ROOF PLUMBING CARRIED TO


SLRs.
SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 03- CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
G FLOOR, WALL & CEILING FINISHES

Rates for floor finishes shall include for temporary rules, screeds,
ground etc., all normal cutting arises, rounded angles and the like,
bedding, pointing, forming joints making good between different
surfaces, around pipes, sanitary fittings and other fixtures and
cleaning down upon completion.

All floor and wall tiles tiles shall be of approved quality ( Lanka
Tiles/ Rocell Brands) and colour. Tile samples shall be provided
for approval by the Engineer/Architect prior to purchase of
materials.
Rates for plaster work shall include for reinforcing joints between
different types of construction material (e.g. block work/
brickwork and concrete work) with 150mm wide galvanized steel
mesh as directed by the Engineer.Rate shall include for Reveals.

Rates for soffit finishes shall include for preparation of surfaces,


cleaning down, smoothing, knotting, stopping, etc., protection of
floors and fittings, removing and replacing door and window
fittings, if required, and cleaning upon completion.

Floor Finishes
Rendering
G.01 20mm thick 1:3 cement sand rendering including neat coloured m2 2.50
cement floating to Floors of Building.
Tiling to Floors
G.02 Supply and Laying of 300 x 300mm Anti slip Ceramic tiles of 2 6.00
m
approved quality and colour, fixed with straight joints in both
ways including all angles corners and including 1:3 cement sand
bedding and pointed in matching colour in Toilet and Bathroom
floors
Wall Finishes
External Faces
Plastering
G.03 15mm thick 1:3 cement sand plaster finished smooth with 2 5.50
m
approved coloured cement floating to plinths.
G.04 15mm thick 1:3 cement sand plaster finished semi rough with to 2 35.00
m
walls, Columns and Sides of Beams & Lintols in Building

Internal Work
Plastering
G.05 15mm thick 1:3 cement sand plaster finished smooth to internal 2 15.00
m
faces of walls, Columns and sides of Beams,tanks & Lintel

Wall Tiling
G.06 Supply & laid 200 x 300mm Glazed Ceramic Wall Tiles of m2 16.50
approved quality and colour for Walls fixed with straight joints in
both ways including all angles corners including 1:3 cement sand
bedding and pointed in matching colour.

SUB TOTAL FOR FLOOR, WALL & CEILING FINISHES CARRIED


SLRs.
TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 03- CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
H PAINTER & DECORATOR
Note:
Rate shall include for preparation of surfaces, cleaning down,
smoothing, knotting, stopping, patching up cracks, etc., protection
of floors and fittings, removing and replacing door and window
fittings, if required, and cleaning upon completion.

All emulsion/ enamel/ weathershield paint shall be of approved


make CIC or equivalent approved by Engineer
Rate to include for the cost for the scaffoldings.

External Faces

H.01 Prepare & apply one alkaline resisting primer coat and two coats m2 35.00
of weather shield emulsion of approved colour and quality to
semi-rough rendered surfaces of walls and Sides of Lintols. (Rate
shall include for reveals)

Internal Faces
Walls
H.02 Prepare and apply one primer coat and two coats of Fungus 2 16.50
m
Resistant emulsion of approved colour and quality to smooth
plastered surfaces to internal faces of walls and sides of Lintel .
(Rate shall include for reveals)
SUB TOTAL FOR PAINTER & DECORATOR CARRIED TO
SLRs.
SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 03- CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
I PLUMBING AND SANITARY INSTALLATION

Unplasticized polyvinyl chloride (uPVC) pipes shall be used in the Note


plumbing installation and they must confirm in every respect to
the requirements of the SLS 147 of 1989 & 1972 or BS 4514.

All fittings and pipe specials used in the plumbing installation Note
shall be suitable and compatible with all respects to the pipe line
to which fittings and specials are fixed.

All sanitary fittings & fixtures shall be American Standards or Note


equivalent.

Rates for plumbing work shall include for:-

(a) Complying with the relevant Sri Lankan, British


or any other standard as given under the
specifications and with the regulations of the Local
Authority and or any other relevant authorities.
(b) Cutting and waste of pipes etc., and joining
pipes.
(c) All specials such as elbows, bends, tees,
junctions, plugs, reducers and similar pipe fittings
except for valves which will be measured
separately.
(d) Connecting pipes to sanitary fixtures and
appliances.
(e) Casing to brick walls etc. and making good all works
disturbed.
(f) Necessary screws, nails sockets, connection
back nuts standard pipe fixing or supporting clips,
saddles, brackets, holder bats, straps etc.
(g) Connecting different types of pipes.
(h) Testing and disinfection after completion.
(i) Submitting shop drawings where necessary.
(j) Excavation, backfilling, disposal of surplus soil Note

Rates for sanitary fittings shall include for:-


(a) Fittings such as taps, waste water outlet,
internal overflows etc. and supporting brackets,
incidental materials for fixing.
(b) Assembling, jointing together fixing components
parts, and jointing to pipes including necessary
coupling and for leaving perfectly clean and in
perfect working order on completion.
(c) Jointing and connecting pipes to sanitary fittings.
(d) Testing and commissioning of the installation.
(e) Making good the work disturbed.
(f) Submitting samples for the approval of the
Engineer.
(g) Protecting the works. Note
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 03- CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
Rates for drainage work shall include for :-
(a) Laying of pipes to falls.
(b) Excavation, backfilling, disposal of surplus soil
(c) All pipe specials such as bends, junctions,
elbows, tees, "Y" junctions, reducers, inspection openings, stop ends, etc.
(d) Connection to sides of manholes etc.
(e) Providing sleeves etc., when pipes pass through
walls, foundations etc.
(f) Giving notices, obtaining permits, paying fees,
fixing, testing and commissioning etc. Note

Sanitary Fixtures
I.01 Supply and installation of floor mounted ceramic water closet Nr 2.00
with 100 mm trap and 6 litre (Dual Flush) capacity low level
ceramic cistern conforming to BS 1125 with plastic syphon, 15
mm angle valve with wall plate, flexible hose connection and all
fixtures and fittings necessary for the completion of water closet
installation. Rate shall include for Bidet shower.Closet shall be of
American Stanadard or equivalent.

I.02 Supply & Installation of Pesdestal type wash basin conforming to Nr 2.00
SLS 377 including bottle trap with 40 mm waste outlet, 15 mm
angle valve with wall plate, 15 mm pillar tap, chrome plated
exposed piping and all fixtures and fittings necessary for the
completion of wash basin installation.Wash Basin shall be of
American Stanadard or equivalent.

I.03 Provisional Sum for Supply and fixing of complete set of Allow Pro. Sum 15,000.00
horizontal and vertical grab-rails in disabled toilet with all
required accessories.
I.04 Supply and installation of Stainless Steel soap dish Nr 2.00
I.05 Supply Installation of mirror of size 750x 600 x6 mm with Nr 2.00
bevelled edges and fixed to the wall with chromium plated studs

I.06 Supplying and fixing of chromium plated 25mm bib tap, chinese Nr 2.00
or indian.(Rate shall include for forcet socket)

I.07 Supply and installation of 150x150 mm Stainless Steel floor gully Nr 2.00
with cover for Toilets .
Water Supply, Wastewater & Drainage Connection
Type 1000 Pipes for Cold Water Supply
I.08 20mm dia. m 4.00
I.09 25mm dia. m 6.00
Valves for Water Supply Lines
Supplying and fixing of approved quality Brass stop valves /Ball
Valves including all necessary fixtures.Valves shall be of Pegler or
equivalent Brands.

I.10 25 mm diameter valve Nr 2.00


Sewerage Disposal System
Type 600 uPVC pipe for Waste Water Lines
I.11 110 mm diameter m 12.00
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 03- CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
Sewer Manholes
I.12 Supplying all material and construct Sewer manholes (Average Nr 1.00
size 450 x 450 x 600 mm internally). Rate included for excavation
& backfilling, screed concreting, formwork, reinforcement @ 150
c/c, 150mm thick concrete base & walls, benching, internal
plastering, precast concrete cover slab with lifting handles, etc.

Septic Tank cum soakage pit


I.13 Supplying all material and construct septic tank cum soakage pits Nr 1.00
in grade 30(20mm) concrete, internal size of Septic Tank
(chamber-1) is 1500 x 900 mm ,1500 mm average depth,100 mm
thick base, 125 mm thick walls and 75 mm thick top slab and
Soakage Pit ( chamber-2) is 900 x 900 mm, 1500 mm average
depth , 125 mm thick walls and 75 mm thick top slab.. Rate
included for excavation in hard rock,, backfilling, formwork,
reinforcement (125kg/m³), concreting, covers slabs with lifting
handles, all necessary pipe work inside the pit, etc.Septic tank
itnernal walls should be plastering with cement floating .Details
as per drawings

SUB TOTAL FOR PLUMBING AND SANITARY INSTALLATION


SLRs.
CARRIED TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 03- CONSTRUCTION OF TOILET FOR VILLAGE SECRETARIAT
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
J ELECTRICAL INSTALLATION
Rates in Bill of Quantities shall include all necessary materials
(Cables, conduits, PVC sunk box, bulbs, switches etc.) and labour
required to complete the electrical installation to good working
order.
Testing and commissioning of all the systems & electrical
installation is to be carried out and inspection report ( 02 sets)
submitted according to the requirements of the power supply by
a Chartered Electrical Engineer.Rate shall be include for
Testing,commissionung and report submission.
Rate Shall include for submission of shop drawings and
submission of draft layouts, conduit layouts etc.for Consultant's
approval before commencing the installation (03 sets)with
Designing of Distribution board, Consumer unit and line diagram
designing by a Chartered Electrical Engineer.

Rate Shall include for submission of As-built drawings on


completion of the contract (03 sets)
Electrical Items (MCB,RCCB etc.) should be of European/Japanese
origin or to the BS or equivalent and items without an accredited
agent in Sri Lanka shall not be accepted. Guarantee cards(Fans
etc.) should be provided from accredited agent before installation.

All the quantities given here are approximated values and


Quantities may change with the actual installation at the site.
All types of fittings, materials, painting and finishes shall be
approved by the Engineer prior to installation.
All panel boards and consumer units should have wire numbering
and a laminated circuit diagram should be pasted on the inside
surface of the door.
Electrical Coduits, which are laid along Earth should be securely
protected by PVC conduits. Earth shall be backfilled properly.

Electrical Coduits, which are laid along internal Roads should be


securely protected by PVC conduits. Cut road shall be filled with
mass concrete and making good to roads.
Light Fitting
Samples should be provided prior to the installtion for electrical
engineer's approval. Guarantee cards should be provided for CFL
bulbs.
J.01 Supply and installation of Pendent Type Lamp Fittings. Rate to Nr 2.00
include the cost of 24W CFL Spiral bulbs (warm white) lamp.Rate
to include for Wiring (including supply of all materials) of the
above light points using approved type PVC insulated PVC
sheathed 1 mm2 copper cable and 1mm2 Cu/PVC earth drawn
through securely fixed concealed PVC conduit
J.02 Supply and installation of Wall Mounted/ Bracket Lamp Fittings. Nr 1.00
Rate to include the cost of 20W approved type bulbs. Rate to
include for Wiring (including supply of all materials) of the above
light points using approved type PVC insulated PVC sheathed 1
mm2 copper cable and 1mm2 Cu/PVC earth drawn through
securely fixed concealed PVC conduit
SUB TOTAL FOR ELECTRICAL INSTALLATION CARRIED TO
SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA

BILLS OF QUANTITIES

SUMMARY OF BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET

ITEM # DESCRIPTION AMOUNT (SLRs.)

A SITE CLEARING & DEMOLITION

B EXCAVATION AND EARTH WORK

C CONCRETE WORK

D MASONRY WORK

E WATER PROOFING

F STRUCTURAL METAL WORK

G METAL WORKS

H CEILINGS WORKS

I ROOFER AND ROOF PLUMBING

J FLOOR, WALL & CEILING FINISHES

K PAINTER & DECORATOR

L PLUMPING WORK

M ELECTRICAL INSTALLATION

N EXTERNAL WORKS

TOTAL FOR BILL NO.04 CARRIED TO GRAND SUMMARY


CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
A SITE CLEARING & DEMOLITION

A.01 Allow Lump Sum for Clearing site, bushes, shrubs under growth Item 1.00
hedges and up rooting trees

A.02 Demolition of existing Concrete Block Masonary Wall including m2 14.20


plastering and clearing debris away from premises.

A.03 Removal of calicut pattern tile roof including Ridge/Hip tiles, from m2 110.00
single storeyed buildings and stacked in ground as directed.

A.04 Removal of roof damaged reepers from single storeyed buildings Lm 500.00
and stacked in ground as directed.

A.05 Removal of existing damage floor concrete as directed.and debris m2 265.00


cart away from site

A.06 Allow lump sum for Removal of existing damaged timber frame Item 1.00
works Doors & windows as directed and making good to wall . No
of frames-17

SUB TOTAL FOR SITE CLEARING & DEMOLITION CARRIED TO


SLRs.
SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
B EXCAVATION AND EARTH WORK
Rates for excavation shall include for :
All necessary shoring, strutting, etc. and removal after completion
of work.
Stabilisation of excavated surfaces, if required.
All working space required, including for planking, strutting,
formwork etc.
Bulking after excavation and disposal of excavated material as
directed.
Backfilling with approved material to required levels and surfaces,
consolidating and ramming by an approved method for over
excavation.
Dewatering, if required.
Measurement for payment for excavation shall be for the net
contact volumes upto the concrete surface.
B.01 Excavation for Wall and Column foundations in any material m3 10.00
except rock requiring blasting, depth not exceeding 1500mm from
the existing Ground level.
B.02 Filling under floors and under Steps with Approved imported hard m3 12.00
earth filling including levelling, watering and compacting in
150mm layers with 98% compaction. (Measured compacted
volume)
B.03 Anti - termite treatment which shall cover excavated trenches, pits, m2 335.00
etc. and the ground covered by floor slabs, foundation &walls and
2m beyond the building perimeter. Work shall be carried out by a
reputed Pest control Company approved by the Engineer.
Particulars of chemicals used and their concentration shall be
forwarded to the Engineer for approval. The Contractor shall
furnish a joint guarantee binding Specialist Sub-contractor and the
Contractor as to the effectiveness of the Anti-termite treatment for
a minimum period of 10 years after completion and cost shall
include for precautionary measures against chemicals being
infiltrated into outside area.Area Measured shalle be Plinth area of
the Building.

SUB TOTAL FOR EXCAVATION AND EARTH WORK CARRIED


SLRs
TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
C CONCRETE WORK
Unless otherwise stated all concrete shall be of grade as per Note
Specifications
Rates for concrete shall include for construction joints, expansion Note
joints or contraction joints as necessary.
Concrete shall be measured as the net area/volume, as shown on Note
the drawings.
Rate for concrete shall include for :
supply, handling at site, depositing, compacting, vibrating, curing
and making good after removal of formwork.
preparation of surfaces, roughening/chipping to the approval of
the Engineer.
providing water stops at temporary construction joints, if Note
necessary.
Reinforcement and Formwork paid separately unless specified in Note
the Item.
Rate for formwork shall include for all necessary boarding, Note
supports, erecting, framing, cutting angles, cleaning, apply
approved foam oil, wetting before placing concrete, removal etc.

Formwork is measured as the net contact surface measurement Note


between formwork and concrete.
All reinforcement shall be as per relevant British Standards having Note
minimum characteristic strength of 460 N/mm2 for ribbed tor
steel and 250 N/mm2 for mild steel.
Rate for reinforcement shall include for supplying, cleaning, Note
cutting, bending, fabricating, binding, placing in position, binding
wires, ties, supporting bars, spaces, chairs, wastage etc.

1 :3 :6 (40mm) Volumed Batched Concrete


C.01 75mm thick Screed concrete under Wall & Column foundation. m2 17.00
1 :2 1/2 :5 (25mm) Volumed Batched Concrete
C.02 75mm thick, mass concrete in floors and Steps in Building and m2 275.00
Ramp
1 :2 :4 (20mm) Volumed Batched Concrete
C.03 Reinforced concrete in Columns Foundation m3 0.75
C.04 Reinforced concrete in Columns m3 1.25
Formwork
C.05 Sides of Colunms m 5.50

Permanent PVC pipe form work


C.06 Sides of Colunms, circular, Using 150mm Diameter type 400 PVC m 6.00
pipe
High yield Steel reinforcement & Mild Steel reinforcement
C.07 In Column Footing kg 18.00
C.08 In Columns kg 70.00
C.09 2 m 20.00
Construction of reinforced concrete (20 N/mm -20mm) lintel of
size 125 mm x 150mm. Rate to including for form work &
reinforcement ( 2 Y12 bars & 6mm ms stirrups) in Building.
C.10 Construction of reinforced concrete (20 N/mm2 -20mm) lintel of m 5.50
size 125 mm x 200mm. Rate to including for form work &
reinforcement ( 4 Y12 bars & 6mm S strup) in Building.

SUB TOTAL FOR CONCRETE WORK CARRIED TO SUMMARY SLRs.


CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
D MASONRY WORK
Notes :
Rate shall include to,
1. All rough and fair cutting, plumbing angles, normal straight
cutting, forming rebated reveals and raking out joints for
plastering.
2. Forming rough and fair groves, throats, mortises,
chases, rebates and holes, stops and miters.
3. Supplying & Fixing

Stone Work
Random Rubble Masonry Work
D.01 Random Rubble( 150 mm-225 mm) Masonry work in 1:5 Cement m3 9.50
sand mortar in Wall Foundation of Building and in Disable Ramp
Block Work
All cement and sand concrete blocks shall comply with BS 6073.

Characteristic strength of block work shall be 2.5 N/mm2


Mortar used for block work/ brick work shall be 1:5 cement and
sand mixture unless otherwise specified.

125mm Cement Block Work


D.02 450x450mm size Column in 100mm thick block work in 1:5 cement m3 2.00
sand mortar for Building.
D.03 125mm thick block work in 1:5 cement sand mortar for walls in m2 80.00
Building.

SUB TOTAL FOR MASONRY WORK CARRIED TO SUMMARY SLRs.


E WATER PROOFING
Damp Proofing
E.01 Damp proof membrane to horizontal surfaces of floors out of 1000 m2 275.00
gauge polythene.
E.02 20mm thick 1:2 cement : sand DPC and finished with two coats of m2 21.00
hot tar blinded with coarse sand.

SUB TOTAL FOR WATER PROOFING CARRIED TO SUMMARY SLRs


CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
F STRUCTURAL METAL WORK
Notes for Steel works
All steel used in the work shall comply with the relevant British
Standards & to the specifications.

All steel shall be new & each member shall be free from any built-
weld or other forms of splice for the full length between joints
shown in or indicated in the drawings unless such splice shall have
been shown in the approved drawings.

The contractor shall submit the specification for the steel which he
proposed to use and obtain prior approval from the Engineer
before commencement of ordering of steel and fabrication.

Welding
No welding shall be done until approval of the prepared surface has
been obtained. All welding shall be carried out under the
supervision of qualified persons.

Brackets for Valance Board


F.01 Supplying, fabricating and fixing of 500mm long brackets made out Nr 14.00
of 25x 6 mm thick MS flat iron bent to shape and welded to steel
purlins at eaves at centres not exceeding 2 m for fixing valanace
and at facia side at centres not exceeding 1 m for fixing barge board
with 2 Nos of 6mm dia holes for fixing valance/barge boards with
necessary accessories.

Roof Purlins
F.02 Supplying and fixing of High tensile steel C10020 (100x50x15,2mm m 34.00
thickness) lipped channel purlins for Roof with all necessary
accessories. Rate to include for bolts and nuts and preparation and
painting two coats of anticorrosive.

SUB TOTAL FOR STRUCTURAL METAL WORK CARRIED TO


SLRs.
SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
G METAL WORKS
Wood work
G.01 Allow lump sum for Repairing and refixing existing damaged Item 1.00
windows frame work (4 Nr) as directed .Rate to include for One
Primer Coat and Two Coats of Enamel paint including preparation
of surface.

G.02 Allow lump sum for Removal of window frames and replaced Item 1.00
damaged timbers and steel Repairing and refixing windows frame
work (2 Nr) as directed .Rate to include for One Primer Coat and
Two Coats of Enamel paint including preparation of surface.

G.03 Allow lump sum for Repairing existing damaged Door frame work Item 1.00
(4 Nr) as directed .Rate to include for One Primer Coat and Two
Coats of Enamel paint including preparation of surface.

G.04 Supply and Fixing Ledge & braced Battened Door double sashes in Nr 9.50
approved Timber with all necessary fittings , sash fixed to the
frame using approved quality butt hinges including all iron monger.
Rate to include for One Primer Coat and Two Coats of
Varnish/enamel including preparation of surface.
G.05 Supply and Fixing Ledge & braced Battened Window double sashes Nr 8.00
in approved Timber with all necessary fittings , sash fixed to the
frame using approved quality butt hinges including all iron monger.
Rate to include for One Primer Coat and Two Coats of
Varnish/enamel including preparation of surface.
Steel Works
G.06 Supply and Fixing 1950mm X 2850mm over all size Hexagonal Nr 6.00
aluminum Netting and Zinc Aluminum wall glading, Consisting of
40mm GI pipe frame work and 12mm X 6mm flat iron internal
frame . Rate to include withone coat of GI prime coating ,1 coats of
anticorrosive paint and two coat of Enamel paint to GI and iron
frame /Gladding work and frame work. as per detail drawing

G.07 Supply and Fixing 1950mm X 3450mmover all size Hexagonal Nr 8.00
aluminum Netting and Zinc Aluminum wall glading, Consisting of
40mm GI pipe frame work and 12mm X 6mm flat iron internal
frame . Rate to include withone coat of GI coating ,1 coats of
anticorrosive paint and two coat of Enamel paint to GI and iron
frame /Gladding work and frame work. as per detail drawing

Roller Shutter Door


G.08 Supplying, fabricating and fixing mechanically operated Aluminium Nr 1.00
Roller Door RS2, 2400mm x 2100mm over all size comprising
louvered effect surface, 40mm minimum visible thickness,
including all necessary fittings

SUB TOTAL FOR METAL WORKS CARRIED TO SUMMARY SLRs.

H CEILINGS
Cement Fibre Ceiling
H.01 Supplying and installation of 4.5mm think Cement Fibre ceiling m2 47.00
fixed with necessary timber frame work (50mm x 100mm joists
and 50mm x 50mm bearers at 600mm c/c) of approved quality
fixed with 40mm x 12mm timber beedings of 40mm x 40mm
timber cove mouldings of approved quality with necessary screws
and nail. Rate shall include for applying two coats of wood
preservative to Timber frame work and One primer coat two coats
of Fungus Resistant emulsion paint to ceiling and two coats of
enamel paint to beedings mouldings.

SUB TOTAL FOR CEILING CARRIED TO SUMMARY SLRs


CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
I ROOFER AND ROOF PLUMBING
Roof Covering
Tile Roofing
I.01 Supplying and placing of Calicut pattern Tile on existing timber Nr 500.00
roof frame work
I.02 Removing g and re-arrange of existing Calicut pattern Tile on m2 150.00
existing timber roof frame work
I.03 Allow Sum for Repairing existing Roof trusses and timber beam Item 1.00
I.04 Fixing of Exiisting Calicut pattern Ridge/hip tiles jointed and m 36.00
bedded in 1:1:4 cement lime and sand mortar coloured to match
tiles.
I.05 Supplying and fixing of Calicut pattern Ridge/hip tiles jointed and m 19.00
bedded in 1:1:4 cement lime and sand mortar coloured to match
tiles.
I.06 Supplying and fixing of 20mm thick, 225mm valance & Barge m 85.00
Fascia board in approved timber using brass screws and complete
with one coat of primer and two coat of enamel painting.Rate
include for preparing existing rafters and making level to fix
valance board
Metal Roofing
Zn/Al alloy coated steel Roofing sheet steel minimum tensile
strength should be 550 N/mm2 and profile should be approved by
I.07 the Engineer
Supplying and fixing of 0.47mm thick Corrugated Zn/Al alloy m2 28.00
coated colour bonded with 3mm thick 3 way reinforced double side
aluminum foil bonded sheet steel roofing on steel lipped channel
with necessary screws & hooks (Steel lipped channel paid
separately.)
I.08 Supplying and fixing of 300mm high Zinc aluminium alloy coated m 15.00
colour bonded valance/barge board.
Roof Plumbing
I.09 Supplying and fixing 0.4 mm thick Zinc aluminium alloy coated m 87.00
colour bonded box type eave gutters of size 130 x 160mm of
approved pattern and colour including end caps, running joints
with including all necessary fittings.
I.10 Supplying and fixing 0.4 mm thick Zinc aluminium alloy coated m 79.00
colour bonded down pipes of size 100mm x 100mm of approved
pattern and colour with brackets and brass screws with wooden
plugs including all necessary molded fittings

SUB TOTAL FOR ROOFER AND ROOF PLUMBING WORKS


SLRs.
CARRIED TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
J FLOOR, WALL & CEILING FINISHES
Floor Finishes
Rates for floor finishes shall include for temporary rules, screeds,
ground etc., all normal cutting arises, rounded angles and the like,
bedding, pointing, forming joints making good between different
surfaces, around pipes, sanitary fittings and other fixtures and
cleaning down upon completion.
All floor and wall tiles tiles shall be of approved quality ( Lanka
Tiles/ Rocell Brands) and colour. Tile samples shall be provided for
approval by the Engineer/Architect prior to purchase of materials.

Rates for plaster work shall include for reinforcing joints between
different types of construction material (e.g. block work/
brickwork and concrete work) with 150mm wide galvanized steel
mesh as directed by the Engineer.Rate shall include for Reveals.

Rates for soffit finishes shall include for preparation of surfaces,


cleaning down, smoothing, knotting, stopping, etc., protection of
floors and fittings, removing and replacing door and window
fittings, if required, and cleaning upon completion.

Rendering
J.01 20mm thick 1:3 cement sand rendering including neat coloured m2 285.00
cement floating to Floors of Building.
Wall Finishes
External Faces
Plastering
J.02 15mm thick 1:3 cement sand plaster finished smooth with m2 12.00
approved coloured cement floating to plinths.
J.03 15mm thick 1:3 cement sand plaster finished semi rough with to m2 10.00
walls, Columns and Sides of Beams
Internal Work
Plastering
J.04 15mm thick 1:3 cement sand plaster finished smooth to internal m2 170.00
faces of walls, Columns and sides of Beams, & Lintel

SUB TOTAL FOR FLOOR, WALL & CEILING FINISHES WORKS


SLRs.
CARRIED TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
K PAINTER & DECORATOR
Note:
Rate shall include for preparation of surfaces, cleaning down,
smoothing, knotting, stopping, patching up cracks, etc., protection
of floors and fittings, removing and replacing door and window
fittings, if required, and cleaning upon completion.
All emulsion/ enamel/ weathershield paint shall be of approved
make CIC or equivalent approved by Engineer
Rate to include for the cost for the scaffoldings.
External Faces
K.01 Prepare plinth surfaces and making good & apply two coats floor m2 85.00
paint in approved colour and quality to surfaces of Plinth & Stage
K.02 Prepare surface & making good and apply two coats of weather m2 262.00
shield emulsion of approved colour and quality to semi-rough
rendered surfaces of walls, Columns . (Rate shall include for
reveals)
Internal Faces
Walls
K.03 Prepare surface & making good and apply two coats of Fungus m2 365.00
Resistant emulsion of approved colour and quality to smooth
plastered surfaces to internal faces of walls,Columns, sides of
Lintel and column faces. (Rate shall include for reveals)

K.04 Prepare and apply one primer coat and two coats of Fungus m2 170.00
Resistant emulsion of approved colour and quality to smooth
plastered surfaces to internal faces of walls,Columns, sides of
Lintel and column faces. (Rate shall include for reveals)
Soffits
K.05 Prepare and apply one primer coat of approved variety and apply m2 12.00
two coats of emulsion of approved colour and quality to smooth
rendered surfaces of soffit.

SUB TOTAL FOR FLOOR, WALL & CEILING FINISHES WORKS


SLRs.
CARRIED TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
L PLUMBING AND SANITARY INSTALLATION
Unplasticized polyvinyl chloride (uPVC) pipes shall be used in the Note
plumbing installation and they must confirm in every respect to the
requirements of the SLS 147 of 1989 & 1972 or BS 4514.

All fittings and pipe specials used in the plumbing installation shall Note
be suitable and compatible with all respects to the pipe line to
which fittings and specials are fixed.
All sanitary fittings & fixtures shall be American Standards or Note
equivalent.
Rates for plumbing work shall include for:-
(a) Complying with the relevant Sri Lankan, British
or any other standard as given under the
specifications and with the regulations of the Local
Authority and or any other relevant authorities.
(b) Cutting and waste of pipes etc., and joining
pipes.
(c) All specials such as elbows, bends, tees,
junctions, plugs, reducers and similar pipe fittings
except for valves which will be measured
separately.
(d) Connecting pipes to sanitary fixtures and
appliances.
(e) Casing to brick walls etc. and making good all works disturbed.

(f) Necessary screws, nails sockets, connection


back nuts standard pipe fixing or supporting clips,
saddles, brackets, holder bats, straps etc.
(g) Connecting different types of pipes.
(h) Testing and disinfection after completion.
(i) Submitting shop drawings where necessary.
(j) Excavation, backfilling, disposal of surplus soil Note
Rates for sanitary fittings shall include for:-
(a) Fittings such as taps, waste water outlet,
internal overflows etc. and supporting brackets,
incidental materials for fixing.
(b) Assembling, jointing together fixing components
parts, and jointing to pipes including necessary
coupling and for leaving perfectly clean and in
perfect working order on completion.
(c) Jointing and connecting pipes to sanitary fittings.
(d) Testing and commissioning of the installation.
(e) Making good the work disturbed.
(f) Submitting samples for the approval of the
Engineer.
(g) Protecting the works. Note
Rates for drainage work shall include for :-
(a) Laying of pipes to falls.
(b) Excavation, backfilling, disposal of surplus soil
(c) All pipe specials such as bends, junctions,
elbows, tees, "Y" junctions, reducers, inspection openings, stop ends, etc.
(d) Connection to sides of manholes etc.
(e) Providing sleeves etc., when pipes pass through
walls, foundations etc.
(f) Giving notices, obtaining permits, paying fees,
fixing, testing and commissioning etc. Note
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
Water Supply, Wastewater & Drainage Connection

Type 1000 Pipes for Cold Water Supply


L.01 20mm dia. m 15.00
L.02 25mm dia. m 45.00
L.03 40mm dia. m 42.00
L.04 50mm dia. m 72.00

Valves for Water Supply Lines


Supplying and fixing of approved quality Brass stop valves /Ball
Valves including all necessary fixtures.Valves shall be of Pegler or
equivalent Brands.

L.05 25 mm diameter valve Nr 5.00


L.06 40 mm diameter valve Nr 2.00
L.07 50 mm diameter valve Nr 2.00
L.08 Supplying and fixing Electric Water Pump and Construction of Nr 1.00
Pump Room as per Drawing. Pump with motor of 1.5 HP (Jinasena
or equvalent), 1 1/2" x 1 1/4" , single phase on cement concrete
bed 600 x 450 x 150mm in 1:2:4 (20mm) mix with 04 Nos 3/8" x 6"
rag bolt & nuts, rendered in cement mortar 1:2 including foot valve
& starter switch complete in working order.
L.09 Supplying and installation of 1000 litre capacity plastishell Nr 1.00
overhead water tank with Steel Framework and 6m high Steel
Tower .as per Drawings.

Type 600 uPVC pipe for Waste Water Lines


L.10 50 mm diameter m 12.00
L.11 63 mm diameter m 40.00

Valves for Waste Water Outlet


Supplying and fixing of approved quality Brass stop valves
including all necessary fixtures.Valves shall be of Pegler or
equivalent Brands.
L.12 50 mm diameter valve Nr 2.00
Waste Water Catch Pits
L.13 Supplying all material and construct water sealed catch pits Nr 2.00
(Average size 300 x 300 x 400 mm internally). Rate included for
excavation & backfilling, screed concreting, formwork,
reinforcement @ 150 c/c, 75mm thick concrete base & 125mm
block walls, internal plastering, precast concrete cover slab with
lifting handles, etc.
Waste Water Manholes
L.14 Supplying all material and construct Intercepter manholes Nr 2.00
(Average size 450 x 450 x 600 mm internally). Rate included for
excavation & backfilling, screed concreting, formwork,
reinforcement @ 150 c/c, 150mm thick concrete base & walls,
benching, internal plastering, precast concrete cover slab with
lifting handles, etc.

SUB TOTAL FOR PLUMBING AND SANITARY INSTALLATION


SLRs.
CARRIED TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
M ELECTRICAL INSTALLATION
Rates in Bill of Quantities shall include all necessary materials
(Cables, conduits, PVC sunk box, bulbs, switches etc.) and labour
required to complete the electrical installation to good working
order.
Testing and commissioning of all the systems & electrical
installation is to be carried out and inspection report ( 02 sets)
submitted according to the requirements of the power supply by a
Chartered Electrical Engineer.Rate shall be include for
Testing,commissionung and report submission.
Rate Shall include for submission of shop drawings and submission
of draft layouts, conduit layouts etc.for Consultant's approval
before commencing the installation (03 sets)with Designing of
Distribution board, Consumer unit and line diagram designing a
Chartered Electrical Engineer.
Rate Shall include for submission of As-built drawings on
completion of the contract (03 sets)
Electrical Items (MCB,RCCB etc.) should be of European/Japanese
origin or to the BS or equivalent and items without an accredited
agent in Sri Lanka shall not be accepted. Guarantee cards(Fans etc.)
should be provided from accredited agent before installation.
All the quantities given here are approximated values and
Quantities may change with the actual installation at the site.
All types of fittings, materials, painting and finishes shall be
approved by the Engineer prior to installation.
All panel boards and consumer units should have wire numbering
and a laminated circuit diagram should be pasted on the inside
surface of the door.
Electrical Coduits, which are laid along Earth should be securely
protected by PVC conduits. Earth shall be backfilled properly.
Electrical Coduits, which are laid along internal Roads should be
securely protected by PVC conduits. Cut road shall be filled with
mass concrete and making good to roads.

Single phase Consumer units


M.01 Supply and installation of wall mounted switch gear cubicle made Nr 2.00
out of polycarbonate enclosure to the approval of the engineer .
Additional space to be provided inside the distribution board
enclosure to install two additional breakers (of capacity with
existing max. outgoing breaker) if necessary.

01 No. 40A, 2-pole MCB 6kA


01 Nos. 40A 2-pole RCCB, 30mA sensitivity
5 - 7 No. 6-32A, 1-pole MCB 6kA
Earth Bar
All internal connections.
Equipment to be to the BS and European/Japanese make

M.02 Provisional Sum for obtaining main power supply connection Allow Pro. Sum 20,000.00
from the Ceylon Electricity Board 6 including all the
correspondence and co-ordination work, builders work. Etc.
M.03 Supply and Installation of service bracket 5'-0" long 2 1/2" x 2 1/2" Nr 1.00
x 1/4" angle iron.
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
M.04 Supply & installation of 32A single phase wiring to pump house . Nr 1.00
Rate to include for MCB, complete with pilot lamp to working order
as per electrical specification.
Cables
M.05 Provisional Sum for Suppling and Installation of Main Cables from Allow Pro. Sum 30,000.00
Energy Meter to MDB and SDB to Cosumer Units
Fans
M.06 Supply & installation of 1400mm sweep ceiling fan Nr 7.00
(European/Japanese make), complete with regulator, fan hook,
extension rod & attachment - Guarantee cards should be provided
from accredited agent. Rate to include for wiring (including supply
of all material, earth wire & switch) of the above ceiling fans using
approved type 1 mm2, Cu/PVC/PVC cable & 2.5 mm2 earth wire
drawn through securely fixed concealed PVC conduits
Socket Outlets
M.07 Supply & installation of 15A shuttered switched single socket Nr 2.00
outlet to comply with BS 1363 . Rate to include for Wiring
(including supply of all material required ) of 15A socket outlets
using approved type 2.5mm2 Cu/PVC/PVC, 2C cable & 2.5mm2
earth cable drawn through securely fixed concealed PVC conduit

M.08 Supply & installation of 5A shuttered switched socket outlet to Nr 6.00


comply with BS 1363.Rate to include for Wring (including supply of
2.5 mm2 earth wire & all other material required ) of above socket
outlet using approved type 1.0mm2 Cu/PVC/PVC cable drawn
through securely fixed concealed PVC conduits
Light Fitting
Samples should be provided prior to the installtion for electrical
engineer's approval. Guarantee cards should be provided for CFL
bulbs.

M.09 Supply and installation of Pendent Type Lamp Fittings. Rate to Nr 23.00
include the cost of 24W CFL Spiral bulbs (warm white) lamp.Rate
to include for Wiring (including supply of all materials) of the
above light points using approved type PVC insulated PVC sheathed
1 mm2 copper cable and 1mm2 Cu/PVC earth drawn through
securely fixed concealed PVC conduit
M.10 Supply and installation of Wall Mounted seat lamp/ Bracket Lamp Nr 9.00
Fittings. Rate to include the cost of 20W approved type bulbs. Rate
to include for Wiring (including supply of all materials) of the
above light points using approved type PVC insulated PVC sheathed
1 mm2 copper cable and 1mm2 Cu/PVC earth drawn through
securely fixed concealed PVC conduit
Main Earthing System
Supply and Installation of all required materials and cables and
connection to respective equipment to provide complete system.
M.11 Supply and Installation of an earth electrode of minimum 16mm Nr 1.00
dia. solid copper rod of length 1.2m or more with a clamp
connection to earth conductor. Earth resistance shall be less than
10 Ohms tested on a dry day. An earth pit of size 300mm x 300mm
x 200mm is to be prepared and covered by concrete plate to
protect the earth electrode.

SUB TOTAL FOR FLOOR, WALL & CEILING FINISHES WORKS


SLRs.
CARRIED TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 04- RENOVATION OF MPCS BUILDING AS MPCS OUTLET
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
N EXTERNAL WORKS
Steel Gate
N.01 Supplying, fabricating and fixing of Gates of sized 4000mm (wide) nr 1.00
x 1650mm ( height) with made out of heavy duty 75x 50mm
Hollow GI Box section and 25mm diameter G.I pipes as shown in
Drawings. . Rate to include for 2 Nos 300 x 300mm RCC pillars for
2.0 m height in 1:2:4 (3/4") concrete 4Y12 reinforced and R6 at
150mm crs stirrups rate include for Excavation base concrete
footing R/F with Y10 @ 200mm c/c both way and 16mm thick 1:4
plastering, 3 Nos pintol and stirrups locking device barrel bolt etc.
and 2 coats of anticorrosive paint and 2 coats of enamel paint and
2 coats of painting to pillers as directed.

Chainlink Mesh Fence


N.02 Supplying and fixing of 1.80 m high (above Ground) gauge 8 PVC m 160.00
coated chainlink mesh on the fence posts. Rate to include for 3 Nos,
top.middle and bottom line wires, stretcher bars and bolting
bracket arrangement with cleats, washers etcf including Casting,
transport & erection of intermediate (at 2.4 m intervals) , corner,
end and strainer RCC fence posts ( 100mm x 100mm at top &
150mm x 150mm at bottom ,Reinforced with 4 no R6 Mild steel
with High tensile wire stirrups spaced at 225mm . Rate to include
for excavation of pits and erection of fence posts along boundary
line with lower end buried in ground and surround with grade 10
concrete .

SUB TOTAL FOR EXTERNAL WORKS CARRIED TO SUMMARY SLRs


CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND
SPACE FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN
JAFFNA
BILLS OF QUANTITIES

SUMMARY OF BILL NO 05- CONSTRUCTION OF TOILET FOR MPCS BUILDING

ITEM # DESCRIPTION AMOUNT (SLRs.)


A Excavation and Earth Work

B Concrete Work

C Masonry Work

D Waterproofing

E Metal Works

F Roofer and Roof Plumbing

G Floor, Wall and Ceiling Finishes

H Paintor & Decorator

I Plumbing and Sanitary Installation

J Electrical Installation

TOTAL FOR BILL NO.05 CARRIED TO GRAND SUMMARY


CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 05- CONSTRUCTION OF TOILET FOR MPCS BUILDING
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
A EXCAVATION AND EARTH WORK
Rates for excavation shall include for :
All necessary shoring, strutting, etc. and removal after
completion of work.
Stabilisation of excavated surfaces, if required.
All working space required, including for planking,
strutting, formwork etc.

Bulking after excavation and disposal of excavated material


as directed.
Backfilling with approved material to required levels and
surfaces, consolidating and ramming by an approved
method for over excavation.
Dewatering, if required.
Measurement for payment for excavation shall be for the
net contact volumes upto the concrete surface.

A.01 Allow Lump Sum for Clearing site, bushes, shrubs under Item 1.00
growth hedges and up rooting trees
A.02 Excavating to reduce level average depth of 150mm m2 12.00

A.03 Excavation for Wall and Column foundations in any m3 2.50


material except rock requiring blasting, depth not
exceeding 1500mm from the existing Ground level.
A.04 Filling under floors and under Steps with Approved m3 2.50
imported hard earth filling including levelling, watering
and compacting in 150mm layers with 98% compaction.
(Measured compacted volume)

SUB TOTAL FOR EXCAVATION AND EARTH WORK


SLRs.
CARRIED TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 05- CONSTRUCTION OF TOILET FOR MPCS BUILDING
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
B CONCRETE WORK
Unless otherwise stated all concrete shall be of grade as per Note
Specifications
Rates for concrete shall include for construction joints, Note
expansion joints or contraction joints as necessary.
Concrete shall be measured as the net area/volume, as Note
shown on the drawings.
Rate for concrete shall include for :
supply, handling at site, depositing, compacting, vibrating,
curing and making good after removal of formwork.
preparation of surfaces, roughening/chipping to the
approval of the Engineer.
providing water stops at temporary construction joints, if Note
necessary.
Reinforcement and Formwork paid separately unless Note
specified in the Item.
Rate for formwork shall include for all necessary boarding, Note
supports, erecting, framing, cutting angles, cleaning, apply
approved foam oil, wetting before placing concrete,
removal etc.
Formwork is measured as the net contact surface Note
measurement between formwork and concrete.
All reinforcement shall be as per relevant British Standards Note
having minimum characteristic strength of 460 N/mm2 for
ribbed tor steel and 250 N/mm2 for mild steel.
Rate for reinforcement shall include for supplying, cleaning, Note
cutting, bending, fabricating, binding, placing in position,
binding wires, ties, supporting bars, spaces, chairs, wastage
etc.

1 :3 :6 (40mm) Volumed Batched Concrete


B.01 75mm thick Screed concrete under Wall & Column m2 4.50
foundation.
1 :2 1/2 :5 (25mm) Volumed Batched Concrete
B.02 75mm thick, mass concrete in floors and Steps in Building m2 2.25
and Ramp
B.03 Construction of reinforced concrete (20 N/mm2 -20mm) m 12.50
lintel of size 100 mm x 150mm. Rate to including for form
work & reinforcment ( 2 Y12 bars) in Building.

SUB TOTAL FOR CONCRETE WORK CARRIED TO


SLRs.
SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 05- CONSTRUCTION OF TOILET FOR MPCS BUILDING
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
C MASONRY WORK
Notes :
Rate shall include to,
1. All rough and fair cutting, plumbing angles, normal
straight cutting, forming rebated reveals and raking out
joints
2. for plastering.
Forming rough and fair groves, throats, mortises,
chases, rebates and holes, stops and miters.
3. Supplying & Fixing

Stone Work
Random Rubble Masonry Work
C.01 Random Rubble( 150 mm-225 mm) Masonry work in 1:5 m3 4.00
Cement sand mortar in Wall Foundation of Building and in
Disable Ramp

Block Work
All cement and sand concrete blocks shall comply with BS
6073.
Characteristic strength of block work shall be 2.5 N/mm2
Mortar used for block work/ brick work shall be 1:5 cement
and sand mixture unless otherwise specified.

100mm Cement Block Work


C.02 100mm thick block work in 1:5 cement sand mortar for m2 32.00
walls in Building.

SUB TOTAL FOR MASONRY WORK CARRIED TO


SLRs.
SUMMARY
D WATER PROOFING
Damp Proofing
D.01 20mm thick 1:2 cement : sand DPC and finished with two m2 4.50
coats of hot tar blinded with coarse sand.
SUB TOTAL FOR WATER PROOFING CARRIED TO
SLRs.
SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 05- CONSTRUCTION OF TOILET FOR MPCS BUILDING
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
E METAL WORKS

Aluminium Works
Notes:
All sections shall be extruded from AA 6063 aluminum alloy
and sections shall be designed to give a rebated internal
and external faces
Aluminum sections for mullions, frames, transoms, heads
and the sills and the other members should strictly comply
with the requirements laid down in the following British
Standard

B.S. 1161 of 1972 – Specification for aluminum alloy


sections for structural purposes

B.S. 1470 of 1972 (Amended in 1987) – Wrought aluminum


and aluminum alloys plate, sheet and strip

B.S. 1474 of 1972 – Wrought aluminum and aluminum


alloys for general engineering Purpose and external
architectural application bars, extruded, down tubes and
sections

Powder coated Aluminium sections where ever specified


shall be film thickness of 60-80 micron,

The Contractor shall refer all relevant drawings and


specification prior to pricing and it shall be his
responsibility to complete the said works to the entire
satisfaction of the Engineer.

All dimensions shown on the drawings shall be verified by


actual site measurement before fabrication and installation.
Any cutting to enlarge the size of opening and any cement
mortar filleting behind frames required after installation
shall be executed by the contractor at his own expense.

Glass panels in windows shall be body frosted/clear float


glass of minimum thickness 5 mm unless otherwise stated.

Glass panels in doors shall be body frosted/clear float glass


of minimum thickness 6 mm unless otherwise stated.

The Contractor shall submit detailed shop drawings and


fabricated samples of typical units of each type for the
approval of the Engineer, 14 days prior to fabrication.
Rate shall include for supplying, fabrication and
installation.
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 05- CONSTRUCTION OF TOILET FOR MPCS BUILDING
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
Rate for windows shall include for provision of heavy duty
stainless steel friction hinges and die-cast Natural Anodized
Aluminium fasteners.
Rates shall include for approved weather strip,
mastic/silicon, sealant, pointing, caulking, jointing, backing,
etc., as specified.

Infilled panels for Aluminium Door sash & Partition panels


shall be colour coated Aluminium composite Panels

Rate for handrail / guardrail shall include for necessary


welding, cutting, embedding, anchoring etc., as per detail
drawings.
Rates for all metal works shall include for necessary
builders work.

Doors

E.01 Supplying, fabricating and fixing Door type D1, 1050mm x Nr 1.00
2100 mm over all size Aluminium framed, gladding panel
single sash swing Door with all necessary accessories.

E.02 Supplying, fabricating and fixing Door type D2, 750mm x Nr 1.00
2100 mm over all size Aluminium framed, gladding panel
single sash swing Door with all necessary accessories.

SUB TOTAL FOR METAL WORKS CARRIED TO


SLRs.
SUMMARY
F ROOFER AND ROOF PLUMBING

Roof Covering

Metal Roofing
Zn/Al alloy coated steel Roofing sheet steel minimum
tensile strength should be 550 N/mm2 and profile should be
approved by the Engineer.Rate shall include for Supplying
and fixing 0.47mm thick Zn/Al alloy coated colour bonded
steel roofing ridge/Hip to match to roof covering

Wood preservative should be applied to timber frame work

F.01 Supplying and fixing of 0.47mm thick Corrugated Zn/Al m2 15.00


alloy coated colour bonded with 3mm thick 3 way
reinforced double side aluminum foil bonded sheet steel
roofing laid on timber roof frame work 100m x 50mm
rafters max c/c 900mm and 50mm x50mm beares max
1000 mm c/c for Toilet as shown in Drawing rate shall
include with timber frame work.Solignam to be applied to
all timber frames

F.02 Supplying and fixing of 20mm thick, 225mm timber valance m 16.00
& Barge Fascia board using brass screws and complete with
one coat of primer and two coat of enamel approved colour
painting
SUB TOTAL FOR ROOFER AND ROOF PLUMBING
SLRs.
CARRIED TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 05- CONSTRUCTION OF TOILET FOR MPCS BUILDING
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
G FLOOR, WALL & CEILING FINISHES
Rates for floor finishes shall include for temporary rules,
screeds, ground etc., all normal cutting arises, rounded
angles and the like, bedding, pointing, forming joints
making good between different surfaces, around pipes,
sanitary fittings and other fixtures and cleaning down upon
completion.
All floor and wall tiles tiles shall be of approved quality (
Lanka Tiles/ Rocell Brands) and colour. Tile samples shall
be provided for approval by the Engineer/Architect prior to
purchase of materials.

Rates for plaster work shall include for reinforcing joints


between different types of construction material (e.g. block
work/ brickwork and concrete work) with 150mm wide
galvanized steel mesh as directed by the Engineer.Rate
shall include for Reveals.
Rates for soffit finishes shall include for preparation of
surfaces, cleaning down, smoothing, knotting, stopping, etc.,
protection of floors and fittings, removing and replacing
door and window fittings, if required, and cleaning upon
completion.
Floor Finishes
Rendering
G.01 20mm thick 1:3 cement sand rendering including neat m2 2.50
coloured cement floating to Floors of Building.
Tiling to Floors
G.02 Supply and Laying of 300 x 300mm Anti slip Ceramic tiles of m2 6.00
approved quality and colour, fixed with straight joints in
both ways including all angles corners and including 1:3
cement sand bedding and pointed in matching colour in
Toilet and Bathroom floors

Wall Finishes
External Faces
Plastering
G.03 15mm thick 1:3 cement sand plaster finished smooth with m2 5.50
approved coloured cement floating to plinths.
G.04 15mm thick 1:3 cement sand plaster finished semi rough m2 35.00
with to walls, Columns and Sides of Beams & Lintols in
Building
Internal Work
Plastering
G.05 15mm thick 1:3 cement sand plaster finished smooth to m2 15.00
internal faces of walls, Columns and sides of Beams,tanks &
Lintel
Wall Tiling
G.06 Supply & laid 200 x 300mm Glazed Ceramic Wall Tiles of m2 16.50
approved quality and colour for Walls fixed with straight
joints in both ways including all angles corners including
1:3 cement sand bedding and pointed in matching colour.
SUB TOTAL FOR FLOOR, WALL & CEILING FINISHES
SLRs.
CARRIED TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 05- CONSTRUCTION OF TOILET FOR MPCS BUILDING
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
H PAINTER & DECORATOR
Note:
Rate shall include for preparation of surfaces, cleaning
down, smoothing, knotting, stopping, patching up cracks,
etc., protection of floors and fittings, removing and
replacing door and window fittings, if required, and
cleaning upon completion.

All emulsion/ enamel/ weathershield paint shall be of


approved make CIC or equivalent approved by Engineer
Rate to include for the cost for the scaffoldings.

External Faces

H.01 Prepare & apply one alkaline resisting primer coat and two m2 35.00
coats of weather shield emulsion of approved colour and
quality to semi-rough rendered surfaces of walls and Sides
of Lintols. (Rate shall include for reveals)

Internal Faces
Walls
H.02 Prepare and apply one primer coat and two coats of Fungus m2 16.50
Resistant emulsion of approved colour and quality to
smooth plastered surfaces to internal faces of walls and
sides of Lintel . (Rate shall include for reveals)
SUB TOTAL FOR PAINTER & DECORATOR CARRIED TO
SLRs.
SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 05- CONSTRUCTION OF TOILET FOR MPCS BUILDING
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
I PLUMBING AND SANITARY INSTALLATION

Unplasticized polyvinyl chloride (uPVC) pipes shall be used Note


in the plumbing installation and they must confirm in every
respect to the requirements of the SLS 147 of 1989 & 1972
or BS 4514.

All fittings and pipe specials used in the plumbing Note


installation shall be suitable and compatible with all
respects to the pipe line to which fittings and specials are
fixed.

All sanitary fittings & fixtures shall be American Standards Note


or equivalent.

Rates for plumbing work shall include for:-

(a) Complying with the relevant Sri Lankan, British


or any other standard as given under the
specifications and with the regulations of the Local
Authority and or any other relevant authorities.
(b) Cutting and waste of pipes etc., and joining
pipes.
(c) All specials such as elbows, bends, tees,
junctions, plugs, reducers and similar pipe fittings
except for valves which will be measured
separately.
(d) Connecting pipes to sanitary fixtures and
appliances.
(e) Casing to brick walls etc. and making good all works
disturbed.
(f) Necessary screws, nails sockets, connection
back nuts standard pipe fixing or supporting clips,
saddles, brackets, holder bats, straps etc.
(g) Connecting different types of pipes.
(h) Testing and disinfection after completion.
(i) Submitting shop drawings where necessary.
(j) Excavation, backfilling, disposal of surplus soil Note

Rates for sanitary fittings shall include for:-


(a) Fittings such as taps, waste water outlet,
internal overflows etc. and supporting brackets,
incidental materials for fixing.
(b) Assembling, jointing together fixing components
parts, and jointing to pipes including necessary
coupling and for leaving perfectly clean and in
perfect working order on completion.
(c) Jointing and connecting pipes to sanitary fittings.
(d) Testing and commissioning of the installation.
(e) Making good the work disturbed.
(f) Submitting samples for the approval of the
Engineer.
(g) Protecting the works. Note
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 05- CONSTRUCTION OF TOILET FOR MPCS BUILDING
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
Rates for drainage work shall include for :-
(a) Laying of pipes to falls.
(b) Excavation, backfilling, disposal of surplus soil
(c) All pipe specials such as bends, junctions,
elbows, tees, "Y" junctions, reducers, inspection openings, stop ends, etc.
(d) Connection to sides of manholes etc.
(e) Providing sleeves etc., when pipes pass through
walls, foundations etc.
(f) Giving notices, obtaining permits, paying fees,
fixing, testing and commissioning etc. Note

Sanitary Fixtures
I.01 Supply and installation of floor mounted ceramic water Nr 2.00
closet with 100 mm trap and 6 litre (Dual Flush) capacity
low level ceramic cistern conforming to BS 1125 with
plastic syphon, 15 mm angle valve with wall plate, flexible
hose connection and all fixtures and fittings necessary for
the completion of water closet installation. Rate shall
include for Bidet shower.Closet shall be of American
Stanadard or equivalent.

I.02 Supply & Installation of Pesdestal type wash basin Nr 2.00


conforming to SLS 377 including bottle trap with 40 mm
waste outlet, 15 mm angle valve with wall plate, 15 mm
pillar tap, chrome plated exposed piping and all fixtures and
fittings necessary for the completion of wash basin
installation.Wash Basin shall be of American Stanadard or
equivalent.

I.03 Provisional Sum for Supply and fixing of complete set of Allow Pro. Sum 15,000.00
horizontal and vertical grab-rails in disabled toilet with all
I.04 required accessories.
Supply and installation of Stainless Steel soap dish Nr 2.00
I.05 Supply Installation of mirror of size 750x 600 x6 mm with Nr 2.00
bevelled edges and fixed to the wall with chromium plated
studs
I.06 Supplying and fixing of chromium plated 25mm bib tap, Nr 2.00
chinese or indian.(Rate shall include for forcet socket)
I.07 Supply and installation of 150x150 mm Stainless Steel floor Nr 2.00
gully with cover for Toilets .

Water Supply, Wastewater & Drainage Connection

Type 1000 Pipes for Cold Water Supply


I.08 20mm dia. m 4.00
I.09 25mm dia. m 6.00

Valves for Water Supply Lines


Supplying and fixing of approved quality Brass stop valves
/Ball Valves including all necessary fixtures.Valves shall be
of Pegler or equivalent Brands.

I.10 25 mm diameter valve Nr 2.00

Sewerage Disposal System


Type 600 uPVC pipe for Waste Water Lines
I.11 110 mm diameter m 12.00
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 05- CONSTRUCTION OF TOILET FOR MPCS BUILDING
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
Sewer Manholes
I.12 Supplying all material and construct Sewer interceptor Nr 1.00
manholes (Average size 450 x 450 x 600 mm internally).
Rate included for excavation & backfilling, screed
concreting, formwork, reinforcement @ 150 c/c, 150mm
thick concrete base & walls, benching, internal plastering,
precast concrete cover slab with lifting handles, etc.

Septic Tank
I.13 Supplying all material and construct septic tank in grade Nr 1.00
30(20mm) concrete, internal size of chamber-1 is 1500 x
900 mm and chamber-2 is 900 x 900 mm, 1500 mm average
depth , 100 mm thick base 125 mm thick walls and 75 mm
thick top slab. Rate included for excavation in hard rock,
backfilling, form work, reinforcement (125kg/m³),
concreting,Finishing cover slabs with lifting handles, all
necessary pipe work inside the tank etc. cement plastering
with cement floating to internal all surfaces ,as per detail
drawing
Soakage Pit
I.14 Supplying all material and construct soakage pits in grade Nr 2.00
30(20mm) concrete, internal size 1800mm Diameter ,
average depth 2500 mm, with 125mm thick block walls and
75 mm thick top slab. Rate included for excavation in hard
rock, backfilling, formwork, reinforcement (125kg/m³),
concreting, covers slabs with lifting handles, all necessary
pipe work inside the pit, etc.
SUB TOTAL FOR PLUMBING AND SANITARY
SLRs.
INSTALLATION CARRIED TO SUMMARY
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 05- CONSTRUCTION OF TOILET FOR MPCS BUILDING
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
J ELECTRICAL INSTALLATION
Rates in Bill of Quantities shall include all necessary
materials (Cables, conduits, PVC sunk box, bulbs, switches
etc.) and labour required to complete the electrical
installation to good working order.
Testing and commissioning of all the systems & electrical
installation is to be carried out and inspection report ( 02
sets) submitted according to the requirements of the power
supply by a Chartered Electrical Engineer.Rate shall be
include for Testing,commissionung and report submission.

Rate Shall include for submission of shop drawings and


submission of draft layouts, conduit layouts etc.for
Consultant's approval before commencing the installation
(03 sets)with Designing of Distribution board, Consumer
unit and line diagram designing by a Chartered Electrical
Engineer.
Rate Shall include for submission of As-built drawings on
completion of the contract (03 sets)
Electrical Items (MCB,RCCB etc.) should be of
European/Japanese origin or to the BS or equivalent and
items without an accredited agent in Sri Lanka shall not be
accepted. Guarantee cards(Fans etc.) should be provided
from accredited agent before installation.

All the quantities given here are approximated values and


Quantities may change with the actual installation at the
site.
All types of fittings, materials, painting and finishes shall be
approved by the Engineer prior to installation.
All panel boards and consumer units should have wire
numbering and a laminated circuit diagram should be
pasted on the inside surface of the door.

Electrical Coduits, which are laid along Earth should be


securely protected by PVC conduits. Earth shall be
backfilled properly.

Electrical Coduits, which are laid along internal Roads


should be securely protected by PVC conduits. Cut road
shall be filled with mass concrete and making good to
roads.
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE
FOR COMMUNITY INTERCATION FOR PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
BILLS OF QUANTITIES
BILL NO 05- CONSTRUCTION OF TOILET FOR MPCS BUILDING
ITEM # DESCRIPTION UNIT QTY RATE AMOUNT
Light Fitting
Samples should be provided prior to the installtion for
electrical engineer's approval. Guarantee cards should be
provided for CFL bulbs.

J.01 Supply and installation of Pendent Type Lamp Fittings. Rate Nr 2.00
to include the cost of 24W CFL Spiral bulbs (warm white)
lamp.Rate to include for Wiring (including supply of all
materials) of the above light points using approved type
PVC insulated PVC sheathed 1 mm2 copper cable and
1mm2 Cu/PVC earth drawn through securely fixed
concealed PVC conduit
J.02 Supply and installation of Wall Mounted/ Bracket Lamp Nr 1.00
Fittings. Rate to include the cost of 20W approved type
bulbs. Rate to include for Wiring (including supply of all
materials) of the above light points using approved type
PVC insulated PVC sheathed 1 mm2 copper cable and
1mm2 Cu/PVC earth drawn through securely fixed
concealed PVC conduit
SUB TOTAL FOR ELECTRICAL INSTALLATION CARRIED
SLRs.
TO SUMMARY
PROJECT:
CONSTRUCTION OF VILLAGE SECRETARIAT AND RENOVATION OF MPCS
BUILDING AS MPCS OUTLET AND SPACE FOR COMMUNITY INTERACTION FOR
PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
CLIENT:
DIVISIONAL SECRETARY -TELLIPALAI AND
MPCS-TELLIPALAI
FUNDING:

UNITED NATIONS DEVELOPMENT PROGRAMME


CONSULTANTS:

RESOURCES DEVELOPMENT CONSULTANTS (PVT) LTD.


PROJECT:
CONSTRUCTION OF VILLAGE SECRETARIAT FOR PALAIVEEMANKAMAM
NORTH AT TELLIPALAI DS DIVISION IN JAFFNA
CLIENT:
DIVISIONAL SECRETARY -TELLIPALAI

FUNDING:

UNITED NATIONS DEVELOPMENT PROGRAMME


CONSULTANTS:

RESOURCES DEVELOPMENT CONSULTANTS (PVT) LTD.


LIST OF DRAWINGS

1. SITE LAYOUT - UNDP/JAF/VEEM/VILLE/LAY/001


2. KEY PLAN - UNDP/JAF/VEEM/VILLE/AR/001
3. DETAIL OF DOORS & WINDOWS - UNDP/JAF/VEEM/VILLE/AR/002
4. LAYOUT & DETAIL OF WALL FOUNDATION - UNDP/JAF/VEEM/VILLE/SD/001
5. LAYOUT & DETAIL OF COLUMN AND COLUMN FOUNDATION - UNDP/JAF/VEEM/VILLE/SD/002
6. LAYOUT & DETAIL OF LINTEL - UNDP/JAF/VEEM/VILLE/SD/003
7. DETAIL OF TRUSS LAYOUT - UNDP/JAF/VEEM/VILLE/SD/004
8. DETAIL OF ROOF TRUSS - UNDP/JAF/VEEM/VILLE/SD/005
9. DETAIL OF ROOF FRAME - UNDP/JAF/VEEM/VILLE/SD/006
10. DETAIL OF TOILET - UNDP/JAF/VEEM/VILLE/SD/007
11. DETAIL OF SOAKAGE PIT cum SEPTIC TANK - UNDP/JAF/VEEM/VILLE/PLU/001
12. DETAIL OF WATER TANK - UNDP/JAF/VEEM/VILLE/PLU/002
13. DETAIL OF ELECTRICAL FLOOR LAYOUT - UNDP/JAF/VEEM/VILLE/ELE/001
14.DETAIL OF FENCE & GATE - UNDP/JAF/VEEM/VILLE/EXT/001
15.DETAIL OF PUMP ROOM - UNDP/JAF/VEEM/VILLE/EXT/002
WELL
N

W E

2.8M
2.2 M 11.1M

1.4M PROPOSED TOILET

1.6M 3.1M

2.85M
1.1M 3.1M
1.2M
PROPOSED SEPTIC TANK
AND SOAKAGE PIT
11.4M
0.83M

PROPOSED BUILDING

FROM KANKESANTHURAI ROAD 1.35M

LANE TO PRIVATE LAND

8M
10.325 M
10.6M

9.1M

Notes TO KDDUVAN-MYLIDDY ROAD


1. All dimensions in meter (m)

DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
Ridge Plate
Tile Roof
Rafter

Purline

Steel truss
Zn/Al coated metal sheet

40mm GI Heavy duty Pipe

Ceiling
600mm Curved sheet
3000
900mm high 2650
wall

900
+450
+300

+0.00

FRONT ELEVATION SECTION ON X-X

X
3400 3400 3400

W1 W1 W1
D
125mm th Wall
Al partition Al partition

+ 450 + 450
3400 125mm th Wall
Office room -3 Office room -2

+ 450
D2 ST D2

C
Al partition Hall Al partition NOS
D2 D2
D1 GLAZED AND PANELLED ALUMINUM DOOR 1200 x 2100 01
TO TOILET

Office room -4
Al partition Al partition
Office room -1 D2 GLAZED AND PANELLED ALUMINUM DOOR 900 x 2100 04
3400
+ 450 + 450
W1 FULLY GLAZED ALUMINUM WINDOW 1200 x 1200 05

SG STEEL HALF DOOR 1200 x 900 02


125mm th Wall D1
B
W1 W1
+ 450

+300
SG- Iron half gate Open
+300
Varendha

4500

150mm dia
PVC R/F
column
SG- Iron half gate
A

1 2 3 4

X PLAN

DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
1200 900

FLOAT
GLASS FLOAT
GLASS

2100 2100
ALUMINUM ALUMINUM
PANEL PANEL

ALUMINUM ALUMINUM
1050 FRAME FRAME

FFL FFL

D1 D2
Glazed & Panelled Aluminum Door Glazed & Panelled Aluminum Door

1200

FLOAT
GLASS
1200
ALUMINUM
SASH 16 1200
1200 150

2100 ALUMINUM
FRAME 1200
1200 900

25
100
900 125

FFL IRON GRILL DETAIL DETAIL STEEL HALF DOOR

W1
Fully Glazed Aluminum Window

DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
1. Structural Concrete Grade
20(20) N/mm
2. Minimum Concrete cover
Thickness 20mm
3. All dimensions in mm
D
4. For elevation refer Architectural
WF 1 WF 1 Drawing
WF 1

WF 1
WF 1

150
C

VARES

300
WF 1 WF 1
400

75
B
WF 1 WF 1 WF 1
450

WF 2 WF 2

VARES

WF 2
400
1 2 3 4

75

300

DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
1. Structural Concrete Grade
20(20) N/mm
225
2. Minimum Concrete cover
225
Thickness 20mm
3. All dimensions in mm
4. For elevation refer Architectural
Drawing

F1 C1 F1 C1

1000

200

75

F1 C1 F1 C1
750

750

F1 C1 F1 C1

600
F2 C2 F2 C2 F2 C2 F2 C2

750 600
1 2 3 4

150

75

DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
1. Structural Concrete Grade
20(20) N/mm
2. Minimum Concrete cover
Thickness 20mm
3. All dimensions in mm
D
4. For elevation refer Architectural
Drawing

C 125 2Y10

R6@150mm C/C

150

DETAILS OF LINTEL

1 2 3 4

DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
D

T1 T1

T2 T2 T2 T2
A

1 2 3 4

DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
NOTES:
(1) REFER ARCHITECTURAL DRAWING FOR COLUMN HEIGHT.
(2) ALL STRUCTURAL STEEL SHOULD BE GRADE 43 (YIELD STRENGTH
225 275N/MM2) IN COMPLINE WITH BS 4360.
4 Nos 100 LONG 12 DIA. RAG BOLT (3) STRENGTH OF THE BOLTS USED FOR CONNECTION
AS OF BS 5950 ARE GIVEN BELOW.

225
GRADE 8.8-HIGH STRENGTH STEEL- YIELD STRESS - 627N/MM2
10mm thick MS Stiffness plate GRADE 4.6-MILD STRENGTH STEEL- YIELD STRESS - 235N/MM2
(4) ALL EXPOSED STEEL COMPONENTS SHOULD BE PROJECTED WITH
TWO COATS OF APPROVED ANTICOROSSIVE PAINT.
Plan at Pin support (5) ALL WELDS SHOULD BE FILLET WELDS OF 6mm LEG LENGTH
HAVING STRENGTH OF 215N/mm SPECIFIED IN TABLE 36 OF BS 5950
225 WITH RESPECT TO COVERD ELECTRODE TYPE E43 COMPLYING WITH
10mm thick
BS 639.
MS Base plate

350
16 Dia 300mm Long Grade 4.6 200x200x8 MS PLATES (6) MINIMUM FILLET WELDING LENGTH (h) TO BE 100mm BOTH SIDE

225
8mm thick Rag Bolts UNLESS SHOWN OTHERWISE.
Mild steel
sole plate (7) ALL STEEL MEMBER SECTION ARE ANGLE IRON
4 Nos 100 LONG 12 DIA. RAG BOLT
225 X 225 RCC Column

Plan at Roller support


Detail at Supports
RCC COLUMN / WALL

Detail F
DETAIL-M
100 x 50 x 14 x 2mm thick
high steel lipped channel purlin

R
E
5
197
2/50X50X6 mm

P- 75x150 Timber Purlin


P R- 50x150 Timber Ridge plate
75X75X6 mm Purlin Cleat
2/50X50X6 mm

D 1733 50X50X6 mm

50X50X6 mm
Purlin connection

2/50X50X6 mm

100.00
A
C
2165 1347
6800
DETAILS OF TRUSS T1

DETAIL-M 40mm GI Heavy duty Pipe


25mm GI Heavy duty Pipe
DETAIL-F

1200
63mm GI Pipe
350

625

250
500
4025 375
365
DETAILS OF TRUSS T2 40mm GI Pipe
DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
12000

100X50 Rafters @ 450 CC

50X25mm Reapers @ 300 CC

50X25mm Reapers @ 300 CC B


B

75X150 mm Purline

1 2 3 4
"C" 7520 Purlin
ROOF PLAN
DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
0.47mm thk Zinc Alum Coated Steel Sheet Roof
50x50 Repers
100x50 Repers

450

2400
450
2050
600 Mirror with frame

1300
700

750

480

Min 300mm

FRONT ELEVATION SECTION ON X-X

700mm Long Hinged support Rail


1200 1800

FG FG
100
325

20mm Bib Tap DPC


Male toilet
2100

300 350
GL
600mmLong H/Hand rail
+300
+300 Female /Disable toilet
450
+150 +300
Al framed, gladding panel Door

PLAN FOUNDATION SECTION

DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
100 100
125 125

150 1. Structural Concrete Grade


75
20(20) N/mm
100 75 2. Minimum Concrete cover
100 25
Thickness 20mm
150 3. All dimensions in mm
100 4. For elevation refer Architectural
225 1370
Drawing

100

125 1500 125 125

125

900
900

125

DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
1500 50x50x6mm Angle Iron @ 200mm spacing

C
D 63x63x6mm Angle Iron

1000l water tank 20mm medium duty 1500


GI Pipe for hand rail

A B
900

50x50x6mm Angle Iron

40x40x6mm Angle Iron

16mm Dia MS bar 450mm spacing

50x50x6mm Angle Iron

5200

400x400x10mm MS Plate

125mm long 10mm dia high strength


450 Bolt & Nut

250

300 150
B B C
A
2500 2500

750

DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
+ 450

+ 450

Hall

Office room -4 Water proof Wall Bracket Lamp


+ 450 + 450
Wall Bracket Lamp

Pendent Lamp(CFL Lamp)

(5A) Socket Outlet

(13A) Socket Outlet

+300 DB

Fan

Switch
Open
Varendha

ELECTRICAL FLOOR PLAN

DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
100
1. Structural Concrete Grade
20(20) N/mm
2. Minimum Concrete cover
Thickness 20mm
3. All dimensions in mm
4. For elevation refer Architectural
75
Drawing

1800

300
GL

GL
250

2400 2400
150

DETAILS OF PVC MESH FENCE

2000 2000

1650
1275

500

100

4000

DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
1. Structural Concrete Grade
20(20) N/mm
2. Minimum Concrete cover
Thickness 20mm
75.000 3. All dimensions in mm
4. For elevation refer Architectural
Drawing

1200.000

1300

FRONT ELEVATION SECTION ON X-X

1200 300.000

100.000

150.000
1400

PUMP ROOM
375.000

75.000

450.000

FOUNDATION DETAILS
X

PLAN

DRAWING TITLE
UNITED NATIONS CONSTRUCTION OF VILLAGE SECRETARIAT FOR DRAWN
DEVELOPMENT PROGRAMME PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CHECKED
RESOURCES DEVELOPMENT
PROJECT REF. No:JAF/NLDP III/87392/002-01
DIVISION IN JAFFNA CONSULTANTS (PVT) LTD, DATE
No: 55-2/1, Galle Road, SCALE
Colombo - 03
DRAWING NO REV. NO
PROJECT:
RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND SPACE FOR
COMMUNITY INTERACTION FOR PALAIVEEMANKAMAM NORTH AT
TELLIPALAI DS DIVISION IN JAFFNA

CLIENT:
MPCS -TELLIPALAI

FUNDING:

UNITED NATIONS DEVELOPMENT PROGRAMME


CONSULTANTS:

RESOURCES DEVELOPMENT CONSULTANTS (PVT) LTD.


LIST OF DRAWINGS

1. SITE LAYOUT - UNDP/JAF/PVEE/MPCS/LAY/001


2. KEY PLAN - UNDP/JAF/PVEE/MPCS/AR/001
3. KEY PLAN - UNDP/JAF/PVEE/MPCS/AR/001
4. DETAIL OF DOORS & WINDOWS - UNDP/JAF/PVEE/MPCS/AR/002
5. DETAIL OF TOILET - UNDP/JAF/PVEE/MPCS/SD/007
6. DETAIL OF SOAKAGE PIT & SEPTIC TANK - UNDP/JAF/PVEE/MPCS/PLU/001
7. DETAIL OF ELECTRICAL FLOOR LAYOUT - UNDP/JAF/PVEE/MPCS/ELE/001
8. DETAIL OF FENCE & GATE - UNDP/JAF/PVEE/MPCS/EXT/001
N

W E
Proposed Conc Post
PVC Mesh Fence
S

Proposed Conc Post


PVC Mesh Fence

Proposed Soakage 26.3


pit 1800 dia 6.9
1.2
4.8
Proposed
Septic Tank 2.4

2.2 3.1
Proposed Toilets

3.0 7.2 4.8

NEW ROAD
EXISTING -TO BE RENOVATED BUILDING

4.0
13.0

Proposed Conc Post


Proposed Conc Post PVC Mesh Fence
PVC Mesh Fence

Proposed Shed
ProposedGate

18.7
ROAD
9.6

Notes
1. All dimensions in meter (m)

DRAWING TITLE
UNITED NATIONS DRAWN
DEVELOPMENT PROGRAMME RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND
CHECKED
SPACE FOR COMMUNITY INTERACTION FOR RESOURCES DEVELOPMENT
PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CONSULTANTS (PVT) LTD, DATE
PROJECT REF. No: JAF/NLDP III/87392/002-02
DIVISION IN JAFFNA No: 55-2/1, Galle Road, SCALE
Colombo - 03 DRAWING NO REV. NO
Stage

SECTION-B-B

B A
4600 2300 2300 2300 2300 2300 2300 2400 2300 4750

W1 W1 W3 W3 W3 W3 W3 W3 W3 W3 W1 W1

T .B
Non Asbestos under ceiling

MPCS STORE
MPCS SALES
OUTLET
7450
Stage 600mm high from main floor Proposed column Proposed column

COMMUNITY INTERACTION

2725 Proposed New


Proposed New
2725 125mm tk wall up
125mm tk wall
T .B to bottom of beam
up to bottom
of truss

300

W2 W2 W2 D2 W2 W2 D2 W2

Proposed New

SECTION A-A W1 Proposed New 125mm


tk wall, 2250mm high D1
125mm tk wall
D1
W1

W1 RD

3000

NOS
D1 FULLY PANELED TIMBER DOOR 1300 x 2400 02

D2 FULLY PANELED TIMBER DOOR 1100 x 2200 03

W1 FULLY PANELED TIMBER WINDOW 1150 x 1250 07


B A
W2 FULLY PANELED TIMBER WINDOW 1950 x 3450 06

W3 FULLY PANELED TIMBER WINDOW 1950 x 2850 08

RD ROLLER SHUTTER 2400 x 2100 01

DRAWING TITLE
UNITED NATIONS DRAWN
DEVELOPMENT PROGRAMME RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND
CHECKED
SPACE FOR COMMUNITY INTERACTION FOR RESOURCES DEVELOPMENT
PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CONSULTANTS (PVT) LTD, DATE
PROJECT REF. No: JAF/NLDP III/87392/002-02
DIVISION IN JAFFNA No: 55-2/1, Galle Road, SCALE
Colombo - 03 DRAWING NO REV. NO
DRAWING TITLE
UNITED NATIONS DRAWN
DEVELOPMENT PROGRAMME RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND
CHECKED
SPACE FOR COMMUNITY INTERACTION FOR RESOURCES DEVELOPMENT
PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CONSULTANTS (PVT) LTD, DATE
PROJECT REF. No: JAF/NLDP III/87392/002-02
DIVISION IN JAFFNA No: 55-2/1, Galle Road, SCALE
Colombo - 03 DRAWING NO REV. NO
1950 1950

Hexagonal netting AL 600 12mm x6mm flat iron internal frame 600 12mm x6mm flat iron internal frame

Zinc AL wall glading 1210 1210

40mm GI pipe frame


40mm GI pipe frame 1640
1040 600
1550
950
FFL
W3 W2
GI and Zinc Al Window GI and Zinc Al Window

1100 1150 1300

TIMBER
PLANKS
TIMBER
SASH
1250 TIMBER
PLANKS

TIMBER

2200
FRAME
2400
TIMBER
PANEL
TIMBER
TIMBER FRAME
FRAME

FFL

D1
D2 W1 Ledged & Braced Battened Door
Timber Panelled Door Fully Timber panel Window

DRAWING TITLE
UNITED NATIONS DRAWN
DEVELOPMENT PROGRAMME RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND
CHECKED
SPACE FOR COMMUNITY INTERACTION FOR RESOURCES DEVELOPMENT
PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CONSULTANTS (PVT) LTD, DATE
PROJECT REF. No: JAF/NLDP III/87392/002-02
DIVISION IN JAFFNA No: 55-2/1, Galle Road, SCALE
Colombo - 03 DRAWING NO REV. NO
0.47mm thk Zinc Alum Coated Steel Sheet Roof
50x50 Reapers
100x50 Rafter

450

2400
450
2100
600 Mirror with frame

1300
700

750

480

Min 300mm

FRONT ELEVATION SECTION ON X-X

700mm Long Hinged support Rail


1. Structural Concrete Grade
1200 1800
20(20) N/mm
2. Minimum Concrete cover
FG FG Thickness 20mm
100 3. All dimensions in mm
325
4. For elevation refer Architectural
Drawing
20mm Bib Tap DPC
Male toilet
2100

300 350
GL
600mmLong H/Hand rail
+300
+300 Female /Disable toilet
450
+150 +300
Al framed, gladding panel Door
Lean conc 75mm tk

PLAN FOUNDATION SECTION

DRAWING TITLE
UNITED NATIONS DRAWN
DEVELOPMENT PROGRAMME RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND
CHECKED
SPACE FOR COMMUNITY INTERACTION FOR RESOURCES DEVELOPMENT
PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CONSULTANTS (PVT) LTD, DATE
PROJECT REF. No: JAF/NLDP III/87392/002-02
DIVISION IN JAFFNA No: 55-2/1, Galle Road, SCALE
Colombo - 03 DRAWING NO REV. NO
100 100
125 125

188
75

100 75
100 25 100
100
150
100 300
225 1370

dia 1800

100

125 1500 125 125

125
50
50
100 100

900 175
900

125
1800 125

2500

1. Structural Concrete Grade 150


20(20) N/mm
2. Minimum Concrete cover 200
Thickness 20mm
3. All dimensions in mm
4. For elevation refer Architectural
Drawing

DRAWING TITLE
UNITED NATIONS DRAWN
DEVELOPMENT PROGRAMME RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND
CHECKED
SPACE FOR COMMUNITY INTERACTION FOR RESOURCES DEVELOPMENT
PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CONSULTANTS (PVT) LTD, DATE
PROJECT REF. No: JAF/NLDP III/87392/002-02
DIVISION IN JAFFNA No: 55-2/1, Galle Road, SCALE
Colombo - 03 DRAWING NO REV. NO
W1 W1 W3 W3 W3 W3 W3 W3 W3 W3 W1 W1

W2 W2 W2 D2 W2 W2 D2 W2

W1 W1
D1 D1

6 way DB

10 way DB
W1
RD

Wall Seat Bracket Lamp

Pendent Lamp(CFL Lamp)

(5A) Socket Outlet

(15A) Socket Outlet

MDB

32Amp 4Pole Isolator

Fan

Switch

DRAWING TITLE
UNITED NATIONS DRAWN
DEVELOPMENT PROGRAMME RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND
CHECKED
SPACE FOR COMMUNITY INTERACTION FOR RESOURCES DEVELOPMENT
PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CONSULTANTS (PVT) LTD, DATE
PROJECT REF. No: JAF/NLDP III/87392/002-02
DIVISION IN JAFFNA No: 55-2/1, Galle Road, SCALE
Colombo - 03 DRAWING NO REV. NO
100

1. Structural Concrete Grade


20(20) N/mm
2. Minimum Concrete cover
75 Thickness 20mm
3. All dimensions in mm
4. For elevation refer Architectural
1800
Drawing

300
GL
GL

250

150
2400 2400

DETAILS OF PVC MESH FENCE

2000 2000

1650
1275

500

100

4000

DRAWING TITLE
UNITED NATIONS DRAWN
DEVELOPMENT PROGRAMME RENOVATION OF MPCS BUILDING AS MPCS OUTLET AND
CHECKED
SPACE FOR COMMUNITY INTERACTION FOR RESOURCES DEVELOPMENT
PALAIVEEMANKAMAM NORTH AT TELLIPALAI DS CONSULTANTS (PVT) LTD, DATE
PROJECT REF. No: JAF/NLDP III/87392/002-02
DIVISION IN JAFFNA No: 55-2/1, Galle Road, SCALE
Colombo - 03 DRAWING NO REV. NO

Das könnte Ihnen auch gefallen