MODEL ACMG4013-02S-443
DIMENSIONAL Φ4.0×1.3
SENSITIVITY -4463dB
DATE
PREP
CHKD
P1/9
PRODUCT SPECIFICATIONS
TYPE: Back Electret Condenser Microphone
Number: ACMG4013-02S-443
T he Microphone including all material and solder joints must be free from Lead and
other restricted substances as per customer requirement.
1. Electrical Characteristics Test Condition (Vs=2.0V RL=2.2KO Ta= 20 ℃ R. H. = 65%)
Item Symbol Test Conditions Minimum Standard Maximum Unit
Sensitivity S Pin=1Pa , f=1kHz -47 -44 -41 dB
Output Impedance Zout Pin=1Pa , f=1kHz 2.2 kΩ
Directivity Omni directional
Current consumption I Vs=2.0V, RL=2.2KO 400 μA
S/N ratio (A) S/N (A) Pin=1Pa, f=1kHz(A Curve) 58 dB
Decreasing Voltage Pin=1Pa , f=1kHz
△S -3 dB
Characteristic Vs=2.0~1.5V
Operating Voltage DC 1 2.0 10 V
Maximal Input
MISPL f=1kHz, distortion≤3% 104 dB
Sound Pressure Level
+8
+10 +5
+3 +3 +3
0
-6 -3 -3 -3 -6
-10
-20
-30
20 50 100 200 500 1000 2000 5000 10000 20000
Frequency (Hz)
Frequency(Hz) 100 200 900 1000 1200 2000 4000 5000 8000
Upper Limit(dB) 3 3 3 0 3 3 3 5 8
Lower Limit(dB) -6 -3 -3 0 -3 -3 -3 -3 -6
P2/9
3. Standard test fixtures
Vc=2.0V,RL=2.2K
Power Std.Mic.
amplifier Speaker B&K4191 Lever meter&sine Lever
Tannoy 16" wave generator recorder
B&K
2716C B&K2012 HP6L
ECM Switch
50cm
+Vs=2.0V
RL=2.2K
FET impedance Output
Converter Term1
FET
C
C1 C2
ECM
unit
Term2 Ground
P3/9
5. Mechanical Characteristics
6. Reliability Tests
To be no interference in operation after drop from 1.5 Meter height onto a concrete
Drop Test surface,each time at three direction in state of packing, The sensitivity change
within ±3dB relative to initial value.
Operating Life Subject samples to +70℃ for 1000 hours under full rated power.
The Microphone exposure at 70℃ for 200 hours, then measuring the sensitivity
High Temperature Test after depositing 2 hours of conditioning at room temperature.
The sensitivity change within ±3dB relative to initial value.
The Microphone exposure at -30℃ for 200 hours, then measuring the sensitivity
Low Temperature Test after depositing 2 hours of conditioning at room temperature.
The sensitivity change within ±3dB relative to initial value.
Condition part at +25℃ for 1 ho ur. Then expose to +70℃ with 95% relative
humidity for 240 hours. Finally allow to dry at room ambient for 4 hours before
Static Humidity
taking final measurements, The sensitivity change within ±3dB relative to initial
value.
After reflow soldering with following condition, the sensitivity of the microphone
Reflow soldering
shall not be changed more than ±1dB from spec.
P4/9
7. Microphone Material
10 Chip Capacitor 1 0201
9 Chip Capacitor 1 0201
8 FET 1 FET
7 PCB 1 FR-4
6 Case 1 Al
5 Cooper Ring 1 Gold Plated
4 Back Plate 1 ALSET/PC-CNZ
3 D/P 1 PET
2 Insulation Spacer 1 Mylar
1 Base 1 LCP
No. Name Quantity Material
P5/9
8. Packaging Specifications
1.7 8
0.5
12.0±0.2
Φ3
5.5
Φ1
Φ4.15
2 4 Φ1.5+0.1
1.75
0
Notes:
1. 10 sprocket hole pitch cumulative tolerance ± 0.2;
2.Camber in compliance with EIA 481;
3.Pocket position relative to sprocket hole measured as true
position of pocket, Not pocket hole.
P6/9
Φ 330±2.5
17.5±1
13.5±1
A Detail
3-1.9±0.2
Ф21.0±0.8
120° Ф13.0±0.2
120°
P7/9
foam board
plastic bag
10 layers
foam board
carton
P8/9
9. Regarding the soldering operation
Ambient
temperature
10-30S
Max 260℃
255℃
220℃
150℃
Max 45S
90±30S
NOTE: After the first reflow, the second reflow is tested on keeping ECM
P9/9