Sie sind auf Seite 1von 1

T12-04-125

T10-23-150 T12-03-150 T10-23-150


T12-25-125 T12-25-125
250
750 550 550
T10-30-150

38
T10-28-150
2000

375
200 T10-29-150

A
T12-18-125 326
T12-16-150 300

T10-10-150 T12-15-150
DETAIL "A" ( PARAPET WALL )
T12-17-125 ( SCALE 1:25 )

1250
T10-21-125
T10-22
150 T10-23-150
T12-24-125 GENERAL NOTES

150
T12-25-125 1. ALL DIMENSIONS ARE IN MILLIMETRES & ALL LEVELS ARE IN METERS ABOVE MEAN SEA
LEVEL (MSL).

2. ALL BARS MARKED "T" SHALL BE HIGH YIELD DEFORMED BARS (TYPE 2) OF YIELD
C STRENGTH NOT LESS THAN 460 N/mm2 AND "R" SHALL BE HOT ROLLED MILD STEEL OF

200
YIELD STRENGTH NOT LESS THAN 250 N/mm2.

2000 3. REINFORCEMENT BARS SHALL BE BENT ACCORDANCE WITH STANDARD


450 SPECIFICATIONS.
450
750 4. LAP LENGTH = 50xØ mm (WHERE Ø IS THE BAR SIZE IN mm).

550 550 5. CONCRETE COVER TO REINFORCEMENT FOR


750 ROOF SLAB /WALL = 45mm
T12-25-125 T12-25-125 FOR BASEMENT = 45mm

R/F DETAILS FOR TYPICAL WING WALL SECTION (C-C) CONCRETE GRADE
T10-23-150 ( SCALE 1:15 )
T10-23-150 a. ALL STRUCTURAL CONCRETE = GRADE 30(19) UNLESS OTHERWISE STATED.

SPECIAL NOTES
C A. LENGTH OF WING WALL "L" TO BE DECIDED TO SUIT SITE CONDITION AS DIRECTED BY
THE ENGINEER.

B. PRECAST CONCRETE GUARD STONES SHALL BE FIXED AT 2500mm C/C OR AS DIRECTED


R/F DETAILS FOR BOTTOM SLAB BY THE ENGINEER.
( SCALE 1:50 ) C. TYPE OF CATCH PIT / CASCADE TO BE DECIDED TO SUIT SITE CONDITIONS AS DIRECTED
BY THE ENGINEER.

D. RUBBLE PITCHING / TURFING SHALL BE USED TO PROTECT. THE EMBANKMENTS AT


HEAD WALL / WING WALL OF THE CULVERT STRUCTURES AS INSTRUCTED BY THE
ENGINEER.

E. INVERT LEVEL OF BOX CULVERT SHALL BE 150mm BELOW EXISTING STEAM BED LEVEL.

F. TOP SLAB THICKNESS IS CONSTANT THROUGHOUT THE BRIDGE.

G. THIS DRAWING TO BE READ IN CONJUNCTION WITH RELEVANT DRAWINGS AND


STANDARD.

DRAWING TITLE : CONTRACTOR ENGINEER


PROJECT:
EMPLOYER: ENGINEER: CONTRACTOR: DETAILS OF SINGLE CELL BOX CULVERT NAME DESIGNATION SIG. NAME DESIGNATION SIG.
REHABILITATION AND IMPROVEMENT ON [NEW CONSTRUCTION] CHECKED &
SURVEYED BY H.A.S.ABEWIKRAMA Surveyor
MINISTRY OF MEGAPOLIS & WESTERN RESOURCES DEVELOPMENT PULOLY-KODIKAMAM KACHCHAI ROAD CHAINAGE:- 0+022 REVIEWED BY
DEVELOPMENT CONSULTANTS PVT LTD. (AB31) PROJECT REV. DATE SIGN. DESCRIPTION DRAWN BY D.HARSHANA Draughtsman CERTIFIED BY
STRATEGIC CITIES DEVELOPMENT PROJECT 55 - 2/1, MAGA ENGINEERING PVT LTD.
4th. FLOOR , SETHSIRIPAYA-STAGE I , GALLE ROAD , CONSTRUCTION ENGINEERS CH 00+000 - CH 14+300 R 0 2019.02.02
CHECKED BY K.L.S.N.FERNANDO C.M. APPROVED BY
200,NAWALA ROAD, R1 2019.03.26 Chainage Shifted
BATTARAMULLA , COLOMBO 3,
NARAHENPITA, SUBMITTED BY S.A.A.JAYASIRI P.M. DATE
SRI LANKA . SRI LANKA.
Tele. - 0112887320 - 2 , FAX. 0112868188 COLMBO 05. CONTRACT NO : SCDP/WB/WK/JF/01
DATE 2019.03.26 SCALE: AS SHOWN DWG. NO: JF/01/SCB/03