General Notes:

The design of this drawing is copyright protected & remains the property of
Timocraft Consulting. The project notes are to be read in conjunction with all
relevant technical specifications.

All work is to be carried out strictly in accordance with the National Building
Regulations, Building Standards Act 103 of 1977, "good building practices"
and the relevant Municipal Regulations.

100 100 Quality of all materials & workmanship to comply with the relevant S.A.B.S.
4,740 4,740 650 and B.S.S. specification standards. The trade contractor shall provide
220 220 finished mock-ups and samples as noted or required by the contract
documents for approval by the architects prior to fabrication.
4,300 650

M
This drawing is not to be scaled, figured dimensions to be used at all times.
Unless noted otherwise, all dimensions are given in millimetres.

M
Contractor is responsible for the correct setting out of the buildings, all
external & all internal walls with particular reference to boundaries, building
W1 W1 lines, etc. No part of the structure, including roof & rainwater goods, is to
encroach upon any servitude area or cadastrial boundary.

220
Contractors are to locate and identify, if any, existing services on site, and to
protect these from damage throughout the duration of the works.

Refer to the relevant consultants drawings for co-ordination of work. The

East Elevation work of all disciplines shall be carefully co-ordinated with the overall
aesthetic appearance of the building.

scale 1:100 All relevant details, levels & dimensions to be checked on site prior to
commencement of work. Any queries are to be forwarded timeously to the
architects.

Discrepancies existing between the drawings of the various trades shall be


brought to the immediate attention of the project manager and the
20.5m2
5,540

5,540
architects.

5,240

4,800
Grano Architects drawings & details show design intent and are meant to be

GENERATOR ROOM indicative of the profiles and detailing required for the work.

W2
Architects decision on the contractors interpretation shall be final and
binding.

Build-in, only approved d.p.c.'s, whether or not these are shown on


drawings, to all external walls at each floor, beam or parapet level & to all
windows, doors, grilles or other opening in external walls. Stepped brickgrip
dpc to all external cavity walls with weepholes at max 900c/c if not stated
differently. Dpc to be min 150mm above n.g.l.

Any queries arising from all the above must be reported to the architects for
clarification before any work is put in hand. Airbricks to local authority
requirements, if not stated otherwise.
D1

220
300

300
North Elevation

735

735
scale 1:100
M

M
100 100
4,740 1,470 1,745 2,175

AS BUILT DRAWINGS

Roof Plan Floor Plan 0


REV. DESCRIPTION DATE

scale 1:100 scale 1:100

South Elevation
scale 1:100

Name Elevation Qnty

W1 2 Name Elevation Qnty


registered architects, development planners, urban designers & projects managers
1,235

6 EBONY STREET, FORTGALE, MTHATHA 5099


PHONE 047 531 0334 FAX 086 665 2052 EMAIL:timocraftconsulting@gmail.com
187E BURGER STREET, PIETERMARITZBURG 3201

West Elevation
PHONE 033 342 9075 FAX 086 665 2052 EMAIL:timocraftconsulting@gmail.com

1,540
scale 1:100 CLIENT:

D1 1
2,100

Supporting beams Roof by specialist


Roof apex +2.700
1,020

W2 1 roof apex level


WPL +2.100
5° u/s of wall plate
1,620 LL +1.800
1,800 u/s of lintel
GENERATOR ROOM
Plastered
PROJECT:

Window Schedule Door Schedule Top of concrete +/-0.000 KATKOP SAPS


dpc grano dpc Top of Concrete Slab
CSC
scale 1:100 scale 1:100 NGL -0.150
DRAWING:
FLOOR PLAN, ROOF PLAN, SECTIONS,
Conc. foundation ELEVATIONS & SCHEDULES
DRAWN: DATE: STAGE NO.

3
A. PHIRI OCT 2013
CHECKED: SCALE:

Sectional View (M-M)


I SHONE (Pr.Arch) AS SHOWN
PROJECT DRAWING REV NO.
NO. NO.

scale 1:100 2014-10 A1004 -


GSPublisherEngine 0.0.100.100