SIPART DR24
Multi-function Unit

7/2 Description
7/2 Application
7/3 Design
7/3 Mode of operation
7/7 Basic functions
7/8 Complex functions
7/16 Serial interface

7/17 Technical data

7/19 Ordering data

7/20 SIPART DR24 input/output


modules
7/20 Overview: applications

Siemens MP 31 · 2008
© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

Application openĆloop control functions; as a singleĆloop controller or for


The SIPART DR24 multiĆfunction unit is used in process parallel operation for up to 4 independent control loops, for
engineering applications for calculation, closedĆloop and openĆ selection controls, cascade control, SPC or DDC mode
loop control. The unit can be freely configured to suit the - Program controller; up to 8 programs
application. During configuring, functions stored in memory - Boiler control with mathematical evaluation of process
(Fig. 7/1) are, through simple allocation, selected and variables (min./max. selection, correction computer etc.)
connected to one another, to the inputs and outputs, and to the
- ClosedĆloop burner control with openĆloop control functions
indicators and pushbuttons of the control and display unit.
- Thermodynamic closedĆloop process control and calculations
No programming knowledge is necessary.
(enthalpy)
The multiĆfunction unit can be connected to higher level
- ClosedĆloop furnace and zone control with programmed
automation systems, control systems or process computers
setpoint control and linearization
using analog, parallel interfaces, as well as via an addressable
busĆbased serial interface. - OpenĆloop and closedĆloop test bed control
The multiĆfunction unit can be installed in panels, desks or - ClosedĆloop control of transport systems (e. g. conveyor
cabinets. belts) with dead time element
- Surge limit control
Application examples - Transmitter for analog and digital process variables to and
- Calculator for mathematical equations, timing sequences, from the serial interface
logic operations and arithmetic operations executed in - Process monitoring (limit violations, failure alarms etc.)
parallel
- Dependent and mutually interlocking/overriding setpoint
- Programmer (clock), also in conjunction with calculations, control
openĆloop and closedĆloop controls
- Multiplexer for process variables and/or setpoints
- ClosedĆloop controller with continuous manipulated variable
- Weighted average calculation using sampled values
and/or threeĆposition step controller; inputs and outputs of

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
controller blocks freely connectable, e. g. to calculation and

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Mathematical functions Logic functions

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
AbS Absolute value And AND
Add Add dFF d flipĆflop

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
AMPL
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Differential amplifier

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
div
FUL
Divide
Function generator (3)
Eor
nAnd
nor
Exclusive OR
NAND, also inverted
NOR, also inverted

7 ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
FUP
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Function generator (2)

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LG
LinE
Log base 10
Straight line equation
or
tFF
tiME
OR
t flipĆflop
Timer

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Ln
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Log base e CoUn Counter

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MuLt Multiply, negation PUM Pulse width modulation (4)
Pot Exponentiation

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
CPt P/T correction computer (2) Switches
root Square root extraction MUP Multiplexer (2)

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SUb
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Subtract, negation ASo Analog variable selector

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SPr Splitrange (8) bSo Digital variable selector
Cnt Demultiplexer

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Time functions
Memory functions

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
AFi Adaptive filter (2)
diF Differentiate (highĆpass) AMEM Analog value memory

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
FiLt Filter (lowĆpass) dFF d flipĆflop
Ain Integrator with analog input, tracked

ÁÁÁ
Ain

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Integrator, analog input (4)
bin
tiME
dti
Timer ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Integrator, digital input (6)

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Dead time element (2)
bin
(see above)
Integrator with digital input, tracked
(see above)

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
CLoc
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Programmer (1) MAME Maximum memory

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MiME Minimum memory
Comparison functions tFF T flipĆflop

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
dEbA Response threshold
Programmer

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LiMi Limiter
MASE Max. selection CLoc Clock (see above)

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MiSE Min. selection
AMPL Differential amplifier

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
CoMP Comparator with hysteresis Functions marked (x) are complex functions that may be

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
used x times (x = 1, 2 or 3). All other functions are basic
Control functions functions that can be connected in any sequence and as

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
}
Ccn
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
PID controller with continuous output often (max. = 109) as required.

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
CSE S controller with internal or The abbreviated function names are displayed in the sevenĆ
CSi external feedback (4) segment display during parameterization and configuring.

Fig. 7/1 Basic and complex functions of the multiĆfunction unit

7/2 Siemens MP 31 · 2008


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

12

11 2
10

8 3

7 4

6 5

Fig. 7/2 SIPART DR24 multiĆfunction unit 1 PE conductor Ć contact spring


2 Slot 6
Design 3 Slot 5
4 Slot 1 (main circuit board)
The SIPART DR24 multiĆfunction unit is of modular design and 5 Slot 2
consequently easy to service and simple to reconfigure or 6 Slot 3
7 Slot 4 (SES: RS 232/RS 485, PROFIBUSĆDP)
retrofit. It consists of a standard device, to which additional 8 Earthing screw
input/output modules can be added in order to extend its range 9 TopĆhat rail (included in delivery of relay modules)
of application. These modules are inserted in slots in the rear of 10 Mains voltage selector
the instrument (Fig. 7/3). 11 Mains plug
12 Power supply unit
The standard device comprises:
Fig. 7/3 SIPART DR24 multiĆfunction unit, rear view
the front module with controls and displays
a main circuit board with CPU and terminal strips and that switching surges from the power pack are prevented

plastic moulded housing with an interface board and power


from getting into the mains supply.
The output from the power pack is sufficient to provide a 24 V
7
pack.
supply to a number of loads (active digital outputs, output
Electrical connections between the various modules are made modules) connected to earth (see Technical data).
via the interface board fixed to the housing. The main circuit
board is inserted in the rear of the unit in slot 1 and locked in
place. The main board has 10Ćpin and 14Ćpin terminal blocks to
which all inputs and outputs of the standard device are Mode of operation
connected. If the number of signals in the standard device is
insufficient for a particular application, a further five slots are The SIPART DR24 multiĆfunction unit is designed around a
available for additional option modules. modern, highlyĆintegrated CMOS microprocessor.
Electrical power for transmitters is provided by a shortĆcircuit The taskĆspecific program created by the user is stored in a nonĆ
proof L+-output (DC 24 V, 100 mA). volatile memory and is therefore protected against power failure.
The power supply unit, an electrically isolated, stabilised Analog input area
switchedĆmode power pack, is situated in a completely The standard device has 3 electronically isolated analog inputs
enclosed metal housing that is screwed to the plastic body of that can accept either standardized voltage (0/0.2 to 1 V or 0/2
the instrument. to 10 V) or current (0/4 to 20 mA) signals.
Versions available: In addition to these inputs, a module with 3 further inputs of
- 6DR2410Ć4 for AC/DC 24 V power supply identical types can be inserted into slots 5 and 6. These inputs
can also be switched between 0 to 10 V and 0/4 to 20 mA. To
- 6DR2410Ć5 for AC 230 V power supply, switchable to AC 115 V.
handle complex control applications, or to connect other input
Short dips in the power supply are bridged without affecting the signals, two additional input modules can be inserted in slots 2
instrument's functionality. All voltages generated by the power and 3. Apart from processing standardized voltage and current
pack are stabilised and shortĆcircuit proof (thermal fuse and signals, these input modules can also be used to connect Pt 100
current monitoring). resistance thermometers, thermocouples and resistance based
The input of the power pack is protected against overvoltages. sensors.
A filter ensures that mains glitches cannot reach the instrument A total of 11 analog inputs are therefore available.

Siemens MP 31 · 2008 7/3


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

32 basic functions 109 artihm. blocks F


dA1.1...dA2.4 r
AbS, Add, AMEM, o
AMPL, And, n
ASo t
Front 0000
bSo dd1.1...dd3.4 m
module
CoMP, CoUn o
dEbA, dEF, diF d
tA1.1 u
div L 1.1...L14.9 l
 Eor e
FiLt b01.F...bh9.F
tA7.F
LG, LiMi, LinE with 3 inputs
+ 1/20 I,U Ln 1 output U
AE1 AE1A AA1.1...AA1.3 1/12 AA1
MAME, MASE
Ć 1/19 U I
MiME, MiSE
MULt
+ 1/22 nAnd, nor U
I,U
AE2 AE2A AA2.1...AA2.3 1/13 AA2
or
Ć 1/21 U I
Pot
root
+ 1/24 I,U SUb U
AE3 AE3A tFF, tiME AA3.1...AA3.3 1/14 AA3
U I
Ć 1/23
33 complex functions 33 artihm. blocks

AFi1. AFi2 5V
2/4 I,U,R Ain1...Ain4
UNI, bin1...bin4 c01.F...c33.F 24 V I
2/3
P, CPt1, CPt2 with 4 inputs bA1.1...bA1.3
2/2 T, AE4A 1/4 BA1
AE4
dti1, dti2 1 output
2/1 V
FUL1, FUL2, FUL3 bA2.1...bA2.3 1/5 2
U
FUP1, FUP2
bA3.1...bA3.3 1/6 3
Slot 2 PWM1 Ć 4/SPR1 Ć SPR8
Options
4 complex functions 4 arithm. blocks bA4.1...bA4.3 1/7 4
3/4 I,U,R
UNI, CLoc d01.F...d04.F bA05 1/8 5
3/3 P, MUP1, MUP2 with 12 inputs
AE5 T, AE5A Cnt1 14 outputs bA06 1/9 6

7 3/2

3/1
V
U 12 complex functions 4 artihm. blocks bA07 1/10 7

Slot 3 bA08 1/11 BA8


Ccn1...Ccn4 h01. F...h04. F
CSE1...CSE4 with 18 inputs
24 V CSi1...CSi4 4 outputs
3AE 6/6
5V 1AA yhold
6/5
bE01 AE6A...AE8A 5BE
BE1 1/15 6/4
AA4...AA6 4BA24V
bE02 6/3
2 1/16 bE10...bE14 +2BE
bA13...bA16 6/2
3 1/17 bE03 2BA Rel.
6/1
3AA/3BE
BE4 1/18 bE04 Slot 6
Options
3AE
5/6
1AA yhold
L+ 1/3 User 5/5
I AE9A...AE11A 5BE
program
AA7...AA9 5/4
M 1/2 memory for: 4BA 24V
bE05...bE09 5/3
+2BE
M 1/1 onPA on bA09...bA12 5/2
AdAP line 2BA Rel.
S3 5/1
M 3AA/3BE
Slot 5

oFPA
L + 24 V CLPA
hdEF off Options
N +5V FdEF line
4/2
UREF FCon SA1.1...SA16.3 RS232
PE – FPoS
APSt SAA1...SAA16 RS485 4/7

CAE4 SbE1...SbE16 PROFIBUS 4/8


CAE5 4/3
 SbA1...SbA16
Slot 4

AE Analog input Slot Terminal


6DR2410Ć4 AC/DC 24 V BE Digital input AA Analog output
6DR2410Ć5 AC 115/230 V, switchable BA Digital output SES Interface module

Fig. 7/4 SIPART DR24 multiĆfunction unit, function diagram Optional

7/4 Siemens MP 31 · 2008


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

Analog output area


Example: Add basic function
The standard device has 3 analog outputs. In addition to these
outputs, a module with 3 analog outputs and 3 digital inputs can b––.F Add n –––
be inserted into each of the slots 5 and 6. The total of 9 analog ncon ∩ .1 +
outputs generate a 0 to 20 mA or 4 to 20 mA signal. ncon ∩ .2 + .A∩
0.000 ∩ .3 +
Slots 5 and 6 can be optionally fitted with an analog output modĆ
ule (yĆhold). This module consists of a microprocessor which
outputs the manipulated variable it receives from the CPU on the A = E1 + E2 + E3
main circuit board. It also contains an alarm output St. In normal ncon Inputs not connected
mode the module is powered by the controller's power pack. It
can, however, also be powered via an external DC 20 to 30 V Fig. 7/5 Basic function block, adder; the preallocated inputs
(e. g
ā . E3 = 0.000) can be easily overwritten if required
supply, in which case the internal and external supply are
ORed.
This analog output module holds the most recent value of the
output variable should communications between the controller's
CPU and the yĆhold processor fail.

Digital I/O area Arithmetic


The standard device has 4 digital inputs (BE1 to BE4) and 8 Analog variables are processed using floatingĆpoint arithmetic
digital outputs (BA1 to BA8). If more are required, the number of within a decimal range of -1019 to +1019.
digital inputs and outputs can be increased by using additional The input and output variables of the multiĆfunction unit are input
option modules. Slots 5 and 6 at the rear of the controller are or output in the signal range 0/4 to 20 mA or 0 to 10 V,
used for this purpose. Both these slots can be used to
corresponding to 0 to 100 %. These ranges represent the
accommodate either a module with 5 digital inputs, or one with
arithmetic values 0 to 1. Arithmetical operations are performed
four DC 24 V digital outputs, or a module with two relay outputs
using these numeric values.
(≤ AC/DC 35 V, ≤ 5 A).
The digital outputs are active and generate a DC 24 V signal. • Connectable parameters
Floating outputs are available, if the relay module with two
digital outputs is used. An interface relay module can also be The linear parameters PL1 to PL40 can be adjusted with a
snapped onto a DIN rail on the rear of the controller. This resolution of 4 digits. The parameters Pd1 to Pd40 - which
additional module has either two or four relays, which are should preferably be used as time constants - can be adjusted
energized directly by the digital outputs. Each relay has a single over a very large logarithmic range. PL and Pd parameters can
be modified onĆline in process operation.
CO contact.
7
Function area • BackĆup battery RAM
The function area is located between the input and output areas. Actual values of counters, timer and memory functions can all
It contains be stored in the event of a power supply failure.
32 basic functions, that can be used as required up to 109
times, and
15 reusable complex functions.
The function area also contains variable parameters and a
number of constants and alarms that may also be connected as
necessary.
In the configuring mode, the required functions can be selected
or defined (configuring mode FdEF), connected (configuring
mode FCon) and positioned in the processing sequence Function area Basic and complex functions"
(configuring mode FPoS). Configuring mode FdEF is used to define any number of
The software connections are freely configurable. Any data function blocks in any sequence. The data sinks (inputs) can be
source can be connected to any number of data sinks. connected (FCon) to any data source (output), e. g. to outputs
Configuring is minimised by eliminating the data sources and from other blocks, to parameters or arithmetic variables. The
sinks of undefined function blocks and by removing any illogical basic functions and their abbreviated names are shown in
source/sink (e. g. analog to digital) connections. Fig. 7/1. The basic function blocks and their characteristic feaĆ
Certain parameters can be modified during operation (onĆline tures are listed on page 7/7.
parameters). The remaining dedicated parameters (e. g. The complex function blocks and their characteristic features
programmer parameters) are set offĆline in configuring mode. are listed on pages 7/8 to 7/16.

Siemens MP 31 · 2008 7/5


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Mode of operation

Communication with higherĆlevel systems Blocking of operator input as well as parameterization and
configuring modes
The SIPART DR24 controller can transmit and receive status
flags, process variables, parameters and configuring switch Switching over to parameterization and configuring mode can
settings via an interface module (option). be blocked using digital signals.
The following interface modules are available: The digital input BLS blocks the switchover to configuring mode.
PROFIBUS DP module However, onĆline control parameters can still be set and
adaptation, as well as normal process operation, performed.
- Transmission rate up to 1.5 Mbits/s
The digital input BLPS, on the other hand, prevents the
- Address range up to 125 instrument from being switched out of process operation mode.
(number of possible stations on the PROFIBUS is determined
The binary function bLB blocks operation of the device.
by the master interface module, the data range of the interĆ
face module, and the number of parametrized process data)
SES module RS 232/RS 485
Indicators (Fig. 7/2)
- Transmission rate 9.6 kbits/s
The SIPART DR24 multiĆfunction unit is equipped with digital and
- RS 232 as pointĆtoĆpoint connection analog indicators.
The two analog indicators consist of a red and a green vertical
- RS 485 bus up to 32 stations LED array. One or two diodes light up alternately, with the
measured value indicated by the center of the field.
The resolution of both indicators is 1.7 %. The green LED array
on the right can be configured as a digital indicator, in which
Monitoring function case digital signals are output to 10 equally spaced LEDs. Two
The multiĆfunction unit contains monitoring functions. Alarms are of the three digital indicators have 4½Ćdigit displays, and one
available as data sources and can be used to activate digital has a 3Ćdigit display. They can all be dimensioned in either
outputs, initiate function sequences or, for example, set analog engineering units or percentage.
outputs to their safety values.
13 additional LEDs are located on the front of the instrument to
display status flags, alarm conditions etc. All LEDs can be
SelfĆdiagnosis connected as required.
Comprehensive selfĆdiagnostics circuits cyclically control the
internal data transfer, or also following a powerĆon reset or
watchdog reset. Process operation (Fig. 7/2)
An error message is displayed automatically on the front module 7 freely connectable pushbuttons are provided on the front
7 when an error is detected. This message provides enough
information to identify the cause of the error and shows how it
panel, which are operatorĆaccessible by pressing the curved
foil. 7
can be rectified. All control and display elements (indicators, LEDs and input
If the analog output module is being used, the St digital output pushbuttons) on the front panel can be switched over to 4 data
on this module interrupts the High signal present during normal sources or sinks for multiple applications.
operation. Customised descriptions can be inserted on the front panel.
The rating plate can also be replaced.
Restart conditions
Depending on the actual loading on the instrument, short dips in
the power supply are bridged by the storage capability of the
power pack. During a longer power cut, the parameters and
configurations being used are saved in a nonĆvolatile, plugĆin
user program memory. The most recent mode of operation,
setpoint value and manipulated variable are also loaded
into failĆsafe memory.
If the SIPART DR24 is equipped with an analog output module
and is being supplied from a separate, failĆsafe source, the
most recent output value is maintained.

7/6 Siemens MP 31 · 2008


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

Serial number of
Basic functions arithmetic block b No. of cycle
A total of 32 basic functions can be used up to 109 b––.F Funktion name n –––
times in any sequence: b01.F to bh9.F E1 .1 A
ncon Input not yet connected E2 .2 .A
Hi; Lo; 1.00; Present for input; E3 .3
can be overwritten Inputs Outputs
Hi High level Data sinks Data sources
Lo Low level  analog value, # digital value

b––.F AbS n ––– b––.F Add n ––– b ––.F AMEM n –––


ncon ∩ .1 A ncon ∩ .1 + ncon ∩ .1
.A∩ ncon ∩ .2 + .A∩ Lo # .2 .A∩
E 0.000 ∩ .3 +
A = |E1| A = E1+E2+E3 E2 = Hi (t = 0)  A = E1 (t = 0)
E2 = Lo, A = E1
b–– .F AMPL n ––– b–– .F And n ––– b ––.F ASo n –––
ncon ∩ .1 ncon # .1 ncon ∩ .1
+
ncon ∩ .2 – .A∩ ncon # .2 & .A# ncon ∩ .2 .A∩
1.000 ∩ .3
x Hi # .3 Lo # .3
A= (E1ĆE2) E3 A = E1 E2 E3
b––.F bSo n ––– b––.F CoMP n ––– b–– .F CoUn n –––
ncon # .1 ncon ∩ .1 Lo # .1
+ m & +m
ncon # .2 .A# ncon ∩ .2 – .A# ncon # .2 CT .A∩
Lo # .3 0.010 ∩ .3 H Lo # .3 R
E2: count pulse (rising edge)
A = Hi if E1  E2+H/2 E3: reset (rising edge)
E3: hysteresis E1 = Hi: block; m = 0.001
b–– .F dEbA n ––– b––.F dFF n––– b––.F diF n –––
ncon ∩ .1 Hi # .1 D ncon ∩ .1
0.010 ∩ .2 .A∩ # .∩ C
Q
.A# 1.000 ∩ .2 x .A∩
2a ncon
Lo # .3 R 1.000 ∩ .3

E2: dead zone  a when E1 = 0 rising edge on E2: A = E1 A = E1 E2 eĆt/E3


E3 = Hi: A = Lo E2 = Vv, E3 = v; E2 E3 = Tv

b–– .F div n ––– b–– .F Eor n ––– b––.F FiLt n –––


1.000 ∩ .1 ncon # .1 ncon ∩ .1
ncon ∩ .2 E1 .A∩ ncon # .2 =1 .A# 1.000 ∩ .2 x .A∩
E2
0.001 ∩ .3 1.000 ∩ .3
A = E1/E2: also A = 1/E2
E3: limit E2 towards 0
A = (E1 E2)  (E1 E2) A = E1 E2 (1 ĆeĆt/E3)
E2 gain; E3 time constant 7
b––.F LG n ––– b––.F LiMi n ––– b––.F LinE n –––
ncon ∩ .1 ncon ∩ .1 ncon ∩ .1 A
lg .A∩ -0.050 ∩ .2 .A∩ ncon ∩ .2 .A∩
E1
1.050 ∩ .3 0000 ∩ .3
A = lg E1 E2: Min., E3: Max., E2  E3 A = E1 E2+E3
A = E1; E2  A  E3
b–– .F Ln n ––– b––.F MAME n ––– b––.F MASE n –––
ncon ∩ .1 ncon ∩ .1 ncon ∩ .1
max.
ln .A∩ Lo # .2 R .A∩ ncon ∩ .2 max. .A∩
-0.050 ∩ .3
A = ln E1 A = max. E1 (t) A = max (E1, E2, E3)
E2 = Hi: A = E1

b––.F MIME n ––– b––.F MiSE n ––– b–– .F MuLt n –––


ncon ∩ .1 ncon ∩ .1 ncon ∩ .1
min. ∩ .2 min.
Lo # .2 R .A∩ ncon .A∩ ncon ∩ .2 x .A∩
1,050 ∩ .3 1.000 ∩ .3
A = min. E1 (t) A = min (E1, E2, E3) A = E1 E2 E3
E2 = Hi: A = E1
b––.F nAnd n ––– b–– .F nor n ––– b––.F or n –––
ncon # .1 ncon # .1 ncon # .1
# .2 & .A# # .2 1 .A# ncon # .2 1 .A#
Hi Lo
# .3 Lo # .3 Lo # .3
Hi
A = E1 E2 E3, also A = E1 A = E1  E2  E3, also A = E1 A = E1  E2  E3
b–– .F Pot n ––– b–– .F root n ––– b––.F SUb n –––
1.000 ∩ .1 ncon ∩ .1 0.000 ∩ .1 +

E1
2.718 ∩ .2 E1 E2E3 .A∩ 0.000 ∩ .2 .A∩ ncon ∩ .2 – .A∩
ncon ∩ .3 0.000 ∩ .3 –
A = E1 E2E3 AĂ Ă
E1 ;Ă E2 :Ă defaultĂ A = E1 Ć E2 Ć E3, also A = ĆE2
for E1 < E2 : A = 0
b–– .F tFF n ––– b––.F tiME n –––
ncon T ncon
# .1 1 & T Q
# .1 C
T
Hi # .2 2 .A# Lo # .2 R t .A#
Lo R 1.000 ∩ .3
# .3
rising edge on E1 flips A rising edge on E1: impulse of duration t on A
E3 = Hi: A = Lo E3 = t; E2 = Hi; A = 0
E2 = Lo: E1 disabled retriggerable

Siemens MP 31 · 2008 7/7


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

Complex functions (functions with dedicated parameters) Filter time constant


Adaptive filters AFi1 and AFi2 tF = oFF, 1 to 9984 s

c––.F AFi1, AFi2 n –––


Autom.
E B A
ncon ∩ .1 >B
.A∩

t
tF <B

tF (onPA) A Output signal B Filter band E Input signal


Fig. 7/6 Effect of the adaptive nonĆlinear filter

The adaptive filter AFi* dampens oscillations in the input process variable - is thus suppressed without affecting the
variable, which occur repeatedly within a band B, using a detection of rapid changes. This is important in controlled
variable time constant tF. Changes outside the band are applied systems where rapid settling is required.
unfiltered to the output. If the noise level changes, the band is
automatically adapted to the new level. Noise - e.āg. from a

Dead-time elements dti1 and dti2


Output = input offset by time td:
c––.F dti1, dti2 n ––– Dead time td 1 to 9984 s
E1 A Stored values 100/td, max. 1/cycle
ncon ∩ .1 .A∩
E2
td
td
After Power on": A = 0 for t ≤ td
1.000 ∩ .2 X
E3 This dead time is multiplied with a factor in E2 and is therefore
Lo # .3
changed from outside. The dead time element can be stopped"
at any time via input 3. The profile remains during standstill".
td (onPA)
E3 = Hi  standstill".

Function generators FUP1 and FUP2


Curve calculator with 13 vertices between -10 and +110 % of
c––.F FUP1, FUP2 n ––– the input signal range:
7 ncon ∩ .1
E
A
A
.A∩
parabolic approximation
Output -199.9 to +199.9 %; magnitude per vertex can be
E parameterized.

Vertices –10, 00, 10 to 110 (oFPA)

Function generators FUL1, FUL2 and FUL3


Curve calculator with 6 vertices between 0 and 100 % of the
c––.F FUL1, FUL2, FUL3 n ––– input signal range.
E A A The output function is formed by the straight sections between
ncon ∩ .1 .A∩ the vertices.
E
The function generators can be used, for example, for
parameter control in the controller function blocks h_.F.

Vertices 00, 20, 40, 60, 80, 100 (oFPA)

Integrator with analog input Ain1 to Ain4 The analog variable on input .1 is integrated.
Tracking mode (N = Hi): the memory A of the integrator is made
b––.F Ain1 ... Ain4 n ––– to track the value of the analog variable UN with tr. Input .1 has
tin, tr LiA, LiE no effect as long N = Hi. The integrator acts as an analog value

E A memory when E.1 = 0 and N = Lo.
ncon .1 .A∩
UN
N Tracking signal
A = 1/tin İE.1dt + UNo
0.000 ∩ .2 t
UN Tracking variable

ÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
N
Lo # .3

tin 1 to 9984 s Integrating time


tin, LiA, LiE, tr (onPA)
ÁÁÁ
ÁÁÁÁÁÁ
LiA
ÁÁÁÁÁÁÁÁÁÁÁ
-199.9 to +199.9 %
}
StartĆofĆscale value memory

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁ
LiE -199.9 to +199.9 % FullĆscale value limitation
tr off, 1 to 9984 s Tracking time (ramp)

7/8 Siemens MP 31 · 2008


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

Integrator with digital inputs bin1 to bin6


Integration is enabled by the digital signals on .1 or .2.
c––.F bin1 ... bin6 n –––
Tracking mode (N = Hi): memory A of the integrator is made to
tin, tr LiA, LiE
track the value of the analog variable UN with tr. The inputs .1
ncon # .1 
+ A
.A∩ and .2 have no effect as long as N = Hi.

-
ncon # .2
UN
t The integrator acts as an analog value memory when E.1 = 0
0.000 ∩ .3 and E.2 = 0 and N = Lo.
N
Lo # .4
tin, LiA, LiE, tr (onPA) A = 1/tin İE.1dt + UNo

The integration time is progressive (100 % approx. 23 s) and


Digital input signals can be generated e. g. by pressing

ÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
constant when tin = 1 to 9984 s.
pushbuttons.
Possible applications:
ÁÁÁ
ÁÁÁÁÁÁ
LiA
ÁÁÁÁÁÁÁÁÁÁÁ
-199.9 to +199.9 %
}
StartĆofĆscale value memory

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁ
- adjustment of analog values using front panel pushbuttons LiE -199.9 to +199.9 % FullĆscale value limitation

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁ
- ramp functions. tr off, 1 to 9984 s Tracking time (ramp)

The variables N and UN enable the stored value to track exterĆ


nal variable (UN) with tr, e. g. for x-tracking, for adaptation of
wint to wext, or for adaptation of yH to ya for automatic, bumpless
switchover when using the controller.

Correction computers CPt1 and CPt2


flow based on standard state. The medium must be in a pure
state, i. e. separation must not occur. The output variable A is
c––.F CPt1, CPt2 n ––– calculated as follows:

A 
Dp x
f

P X A
1.000 ∩ .1 .A∩
E2
(E 2, E 3)
ncon ∩ .2
E3
f(E2·E3) (P E-P A) E 2  P A
∩ .3
f (E 2, E 3) 
ncon
(t E-t A) E 3  t A
tA, tE, PA, PE (oFPA)
The measuring range is standardised to the formula using the
7
parameters tA, tE, PA and PE. tA and PA can take a value
Correction computers are used to calculate the rate of flow of between 0.01 to 1.000, tE and PE between 1.000 to 99.99.
gases from the differential pressure p, correcting for fluctuations This flow correction computer corrects errors caused by
in pressure and temperature. Mass flow and volume flow based changes in the state variables of the medium (pressure,
on the operational state can be corrected, as well as volume temperature).

q
Pressure p Temperature t Differential
pressure p

kp/cm2

Transmission of
measured value

p
t
Calculation
p
Function block rE
q

Siemens MP 31 · 2008 7/9


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

Split range SPr1 to SPr8


The split range function comprises a straightĆline equitation
c––.F SPr1 ... SPr8 n ––– between the base point SPA (output value 0) and the turning
point SPE (output value 1).
E A
ncon ∩ .1 .A∩
Outside this range, the output is limited to 0 or 1. By setting the
E
two private onPA parameters SPA and SPE it is possible to imĆ
plement both rising and falling sections.

SPA, SPE (onPA)

A A
100 %
100 %

SPA < SPE ⇒ rising SPA > SPE ⇒ falling

E E
SPA SPE 100 % SPE SPA 100 %

PulseĆwidth modulator
The pulseĆmodulator converts an analog signal into a pulseĆ
c––.F PUM1 ... PUM4 n ––– widthĆmodulated binary signal.
E A
A Private parameters (onPA)
ncon ∩ .1 .A# tM Period
tAE Minimum on time
t Example:
7 tAE, tM (onPA)
Input value:
Period:
0.3
4s
⇒ On time 1.2 s
Pause time 2.8 s

MeasuringĆpoint selector MUP1, MUP2 (multiplexer)


The multiplexer enables up to 8 analog inputs to be switched
Serial number of
No. in cycle through to a single output. This switching operation is controlled
arithmetic block
by the signal on the cycle input d0*.09 (switch over in a closed
d0_.F MUP1, MUP2 n ––– ring). Each switching signal is indicated by a Hi signal on a
separate output. These signals can, for example, be connected
ncon ∩ .01 to the programmer's inputs to select a particular program. In
0.000 ∩ .02 addition, the current position can be displayed by connecting
0.000 ∩ .03 .1A ∩
the d0*.10 output to the digital display dd3.
0.000 ∩ .04
.05 The StP parameter (number of switching steps) is used to select
0.000 ∩
StP1
.2A # the maximum number of measuring points (2 to 8). The factory
0.000 ∩ .06
2
# setting is 8.
0.000 ∩ .07 .3A
3
0.000 ∩ .08 .4A #
4
.5A #
5
1 .6A #
6
ncon # .09 .7A #
7
8 .8A #
8
StP .9A #.

Reset D
Lo # .10 .10(A)∩
A

StP (oFPA)

7/10 Siemens MP 31 · 2008


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

Demultiplexer Cnt1
The demultiplexer is primarily used for switching over the disĆ
Serial number of play and control elements (multiple controller, max. 49).
arithmetic block No. in cycle
d_ .F Cnt.1 n ––– It can be defined once. The demultiplexer is used to output the
counter value in binary code according to the following table.
Enabling is carried out controlled by the edge at the clock input
d*.1 (switching over in closed ring, limited by private parameter
StP1 StP).
.1A#
2
.2A# The counter can be set to position 1 by a High signal via the
3
1 .3A# Reset input d*.2. The postion can be displayed by connecting
ncon # .1 4 .4A# the output to display dd3.
4
StP

Reset
StP 1A 2A 3A 4A 5A 6A
.5A#
Lo # .2
.6A# 1 1 0 0 0 0 0
D
2 0 1 0 0 1 0
A
.7A∩ 3 0 0 1 0 0 1
4 0 0 0 1 1 1

StP 2, 3, 4 (oFPA)

ÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁ
Controller blocks Ccn1 to Ccn4, CSi1 to CSi4 and CSE1 to CSE4 h0*.08 : H Control signal for switching operating

ÁÁÁÁÁ
ÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Four of the controller blocks listed below can be used in each

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁ
instrument, independent of the type of controller.
mode of controller
H = Lo: y = ya (automatic mode)
H = Hi: y = yH (manual mode)

ÁÁÁÁ
ÁÁÁÁÁÁÁ
Á
Á ÁÁÁÁÁÁÁÁÁÁÁÁ
Input signal conditioning takes place outside the controller

}
block. The controllers have inputs for the control deviation. h0*.09 +y Digital inputs for incremental adjustment

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ h0*10 : -y


of manipulated variables (tracking or
7
ÁÁÁÁ
ÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Inputs manual mode)

}
h0*11 : +yBL

ÁÁÁÁÁÁ
Á ÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
h0*.01 : Av Enable adaptation input Digital inputs for directionĆdependent
direction dependent
h0*.02 : x Resulting controlled variable for adaptation h0*12 : -yBL blocking of manipulated variables

ÁÁÁÁ
ÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁ
h0*.03 : yz
ÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
}
Disturbance variable feedforward to h0*13 : SG1 Controlled variable inputs for

ÁÁÁÁÁÁ
Á ÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
manipulated variable ya h0*14 : SG2 p
parameterized control of control

}
h0*.04 : xdp parameters KP, Tn and d Tv.

ÁÁÁÁ
ÁÁÁ
Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁ Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
h0*15 : SG3
h0*.05 : xdI control deviation inputs
p h0*16 : N Digital input for manual or tracking mode

ÁÁÁÁÁÁ
h0*.06 : xdD
ÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ h0*17 : YN Analog input for manual manipulated

ÁÁÁÁÁÁ
Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
The controlled variable or another process variable
variable can be differentiated instead of the

ÁÁÁÁÁÁ
Á ÁÁÁÁÁÁÁÁÁÁÁÁ deviation xd (dynamic disturbance variable

ÁÁÁÁ
ÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁ
feedforward)
h0*.07 : P Control signal for changing structure

ÁÁÁÁÁÁ
Á ÁÁÁÁÁÁÁÁÁÁÁÁ
Parameters
P = Lo: PI, PlD cP Proportional gain

ÁÁÁÁÁÁ
Á ÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
P = Hi: P, PD
tn Reset time

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
P = Lo  PID (z): tv Derivative action time
vv Derivative action gain
ya=yz+xwP·KP+ywI +xwI ·KP(1+1/ jω Tn )+ xwD ·KP · jω Tv / (1+jω Tv/Vv)

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
AH Response threshold
Yo Working point

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
P = Hi  PD (z):
YA Manipulated variable limitation, minimum
ya = yz + xwP · KP + y0 + x wD · KP · jω Tv / (1 + jω Tv/Vv ) YE Manipulated variable limitation, maximum

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ tY Actuating time

ÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
with Yo = AUto: Working point automatically adjusted in
tA Minimum pulse length
manual mode so that Yo = YH in each case

ÁÁÁÁÁÁÁÁÁÁÁÁ
with Yo ≠ AUto: Working point fixed at Yo tE Minimum pulse interval

Siemens MP 31 · 2008 7/11


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

K controller (with continuous output) Ccn 1 to Ccn4

h0_.F Ccn1, Ccn2, Ccn3, Ccn4 n –––

Lo # .01 Av
y
∩ .02 x
0.000 Adaptation .1A#
AL

+
AH –
YA, YE

yz
0.000 ∩ .03 + 1
Kp

ncon ∩ .04 xdP Kp xd


+

Tv,VV,Kp

∩ .05 xdD YA .2A∩


0.000 +

+ - .3A∩
Tn, Kp Y
YBL YH

0.000 ∩ .06 xdl YN

PI
P +
Yo

Yo HN
P
7 Lo # .07
H
Lo # .08 tY
+y
Lo # .09
y tY
Lo # .10
+ -
YBL
Lo ∩ .11 +YBL

Lo ∩ .12 -YBL

SG1 N
1.000 ∩ .13 x kp
cP
1.000 ∩ .14 SG2
x
tn Tn

1.000 ∩ .15 SG3


x Tv
tv
cP, tn, tv adjustable parameters
# .16 N
Lo kp, Tn, Tv effective parameters
∩ .17 YN
0.000

cP,tn,tv,vv,AH,Yo,YA,YE,ty (onPA)

Outputs:
h0*.1A: Digital output signal Adaptation in progress"
h0*.2A: Controller manipulated variable output signal (automatic mode)
h0*.3A: Manipulated variable output signal (manual, tracking or automatic mode)

7/12 Siemens MP 31 · 2008


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

S controller (with threeĆposition step controller and internal positional feedback) CSi1 to CSi4.
A positional feedback is not required with this controller, as the time response of the actuating motor is simulated by an integrator in
the controller.

h0_.F CSi1, CSi2, CSi3, CSi4 n –––

Lo # .01 Av
YR
0.000 ∩ .02 x
Adaptation .1A#
AL

+
AH –
YA, YE

yz
0.000 + 1
∩ .03 Kp
Kp xd
ncon ∩ .04 xdP
+

Tv,VV,Kp

0.000 ∩ .05 xdD


+

Tn, Kp

0.000 ∩ .06 xdl

7
H
Lo # .08 ty, tA, tE

Lo +y & +y


# .09 >100 .2A#
y <0 y
Lo # .10 &
.3A#

+YBL
Lo # .11
-YBL
Lo # .12
∩ .13 SG1
1.000 x kp
cP
1.000 ∩ .14 SG2
tn x Tn

1.000 ∩ .15 SG3


x Tv
tv
ncon ∩ .16 YR
cP, tn, tv adjustable parameters
kp, Tn, Tv effective parameters

cP,tn,tv,vv,AH,ty,tA,tE (onPA)

Outputs:
h0*.2A: +y
h0*.3A: -y } positional increments for the actuator
h0*.16: YR position feedback (for display only)

Siemens MP 31 · 2008 7/13


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

S controller (with threeĆposition step controller and external positional feedback) CSE1 to CSE4

h0_.F CSE1,CSE2,CSE3,CSE4 n –––

Lo # .01 Av
YR
0.000 ∩ .02 x
Adaption
AL
.1A#

+
AH – YA, YE

yz
0.000 ∩ .03 Kp
+ 1

Kp xd
ncon ∩ .04 xdP
+
Tv,VV,Kp

0.000
∩ .05 xdD
+

Tn, Kp

0.000
∩ .06 xdl

PI
P +
Yo

Yo
P
7 Lo # .07
H
Y

Lo # .08 ty, tA, tE

+y + & +y


Lo # .09 >100 .2A#
y <0 & y
Lo # .10 –
.3A#
YR .4A∩
+YBL xds
Lo # .11
-YBL N
Lo # .12
∩ .13 SG1
1.000 x kp
cP
1.000 ∩ .14 SG2
tn x Tn

1.000 ∩ .15 SG3


x Tv
tv
YR
ncon ∩ .16
N cP, tn, tv adjustable parameters
Lo # .17
kp, Tn, Tv effective parameters
YN
0.000 ∩ .18

cP,tn,tv,vv,AH,Yo,YA,YE,ty,tA,tE (onPA)

Outputs:
h0*.2A: +y
h0*.3A: -y } positional increments for the actuator
h0*.4A: xds control deviation of positional control loop
h0*.16: YR position feedback

7/14 Siemens MP 31 · 2008


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

Programmers Parameters
The programmer enables 2 analog outputs and 8 digital outputs CLFo : Clock format: h/min or min/s
to be assigned a common time basis with a maximum of 40 time CLCY: Number of cycles
intervals. These 40 intervals can be divided among up to 8

ÁÁÁÁÁÁÁÁÁ
CLSb : Acceleration factor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁ
independent programs, each of which is assigned an
appropriate number of time intervals.

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Time
The time intervals for the programs are entered in the selected Acceleration

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
format in either h/min or min/s. The values of analog outputs factor 1 week 1 day 1 hr 1 min
360 28 min 4 min 10 s -

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
and/or the status of digital outputs are then allocated to each
time interval. The specified programs can be executed once, 168 60 min - - -

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
more than once, and also cyclically. The clock can also be 120 84 min 12 min 30 s 0.5 s
speeded up for testing purposes. 60 168 min 24 min 1 min 1s

The clock is controlled via the Start, Stop, Reset and HighĆspeed
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
24 7h 1h 2.5 min 2.5 s

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
12 14 h 2h 5 min 5s
inputs. The program to be executed is selected using the d0*.05 6 28 h 4h 10 min 10 s

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
to d0*.12 inputs, and started by setting Start = Hi. The timing 3 56 h 8h 20 min 20 s
sequence can be monitored via the time from start", time in
interval", interval" and stop clock" outputs.
CLPr : Number of intervals/program
CLti : Length of interval
CLA1, 2 : Analog output value 1 or 2
CLb1 to
CLb8 : Digital status Hi or Lo in respective interval

Interval no.
1st program 2nd program

Serial no. of
arithmetic block No. in cycle Interval start/
d0_.F CLoc.1 n ––– end points

Start Time from start


ncon # .01 .1A ∩
Lo # .02
Stop & Time in interval
.2A ∩
1st program 2nd program ... etc.
Reset Interval
Lo # .03 < .3A ∩ t = 0 of 1st interval
HighĆspeed Stop clock
Lo # .04 .4A #

ÁÁÁ
ÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁ
Select via SES
Lo # .05 A1
" Pr.2
# ∩

ÁÁÁ
ÁÁÁ
Á ÁÁ ÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁ
Lo .06 .5A
" 3 Meaning of interval indicator
Lo # .07
A2 InterĆ
" 4 ∩

ÁÁÁ
ÁÁÁ
Á ÁÁ
ÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁ
Lo # .08 .6A
" 5 val CLA.. CLb.. with CLA with CLb
Lo # .09

ÁÁÁ
ÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁ
" 6 b1
Lo # .10 .7A # 00.1 80 % - Start 1st interv. (t=0) -
Lo " 7 b2

ÁÁÁ
ÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁ
# .11 .8A # 01.1 60 % Hi End 1st interval 1st interval
Lo Select Pr. 8 b3
# .12 .9A # 02.1 20 % Lo 1st progr. End 2nd interval 2nd interval

ÁÁÁ
ÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁ
b4
.10.(A)# 03.1 20 % Lo End 3rd interval 3rd interval
b5
.11.(A)# 04.1 ↓ 50 % Hi End 4th interval 4th interval

ÁÁÁ
ÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁ
b6
.12.(A)# 00.2 20 % - Start 1st interv. (t=0)
(t 0) -
b7

ÁÁÁ
ÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁ
.13.(A)# 01.2 80 % Hi End 1st interval 1st interval
b8 .14.(A)# 02.2 60 % Lo 2nd progr. End 2nd interval 2nd interval
↑↑
CLFo,CLCY,CLSb,CLPr,CLti Interval no. Program no.
CLA1,2 CLb1...8 (CLPA) in display dd3

Siemens MP 31 · 2008 7/15


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Description

Serial interface bumpless changeover towards (SA(E).3 is to be made between


Input and output functions of the serial interface this data source and another.
Freely connectable inputs and outputs (SAE, SbE and SAA, SbA A cyclical watchĆdog function can be used to monitor traffic on
respectively) and dedicated readĆonly inputs and outputs (AI, DI the interface. A monitoring period can be specified using the
and AO, DO respectively) of the multiĆfunction unit can be read/ parameter Cbt; when the elapsed time between two telegrams
written by the SES. Parameters and configuring data can also exceeds this period, the digital input SbE1 is set to Lo. If
be read/written. required, this could be used to trigger changeovers within the
multiĆfunction unit.
The data sinks SA(E).1 (tracking variable) and SA(E).2 (tracking
control signal) are used to track the data source SA.3 if a

Data sink Data sources

Read SES Read/Write

UN
*) ncon ∩ SA1.1
SA1.3∩
Lo #SA1.2
N . SA(E)
.. serial
.
∩ S16.1
UN . analogĆ
*) ncon input
.
S16.3∩
N
Lo # S16.2
SAA
serial 0.000 ∩ SAA1
analog ..
.
output ∩ SA16
0.000 SbE1# SbE
.. serial
.
digital
Lo #SbA1 SbF6# input
..
SbA .
serial Lo #Sb16
digital
output
AE 1 n
7 ..
.
AE11 n
bE 1 #
..
.
bE14 #
nAA1.3
.
..
nAA4.3
nAA5
.
..

nAA9
#bA1.3
.
..

#bA4.3
#bA5
.
..
#bA16

onPA
Parameter FCon
oFPA
Configur. FPoS
CLPA CAE4
hdEF CAE5
bdr, Lrc, LEt, Prt, Snr, Cbt (oFPA)
SES = YES or no (hdEF)
*) Default setting: 0.000
Data sink and data sources are not displayed in FCon if SES = no in hdEF

7/16 Siemens MP 31 · 2008


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Technical data

Technical data Power supply


General data
Rated voltage Switchable
Mounting position Any AC 230 V AC 115 V AC/DC 24 V
Climatic classes Operating AC 187 AC 93 AC 20 DC 20
- Storage: 1K2 according to voltage range to 276 V to 138 V to 28 V to 35 V 4)
DIN IEC 721 Part 3Ć1 -25 to +75 °C
- Transport: 2K2 according to Frequency
DIN IEC 721 Part 3Ć2 -25 to +75 °C range 48 to 63 Hz -
- Operation: 3K3 according to Peak voltages
DIN IEC 721 Part 3Ć3 0 to +50 °C not periodic to
VDE 160
Degree of protection to
EN 60 529 1.3 ms ≤ 780 V ≤ 390 V ≤ 70 V
Front module IP 64 10 μs ≤ 1500 V ≤ 1500 V ≤ 500 VĂă
Housing IP 30
External
Connections IP 20
current Iext5) 450 mA

Controller design Power


consumption
Electrical safety Active power/
- to DIN EN 61 010 Part 1 apparent
power 6)
- Protection class I
Stand. contr.
- Safety separation between supply connection and field signals
- without
- Clearances and creepage paths for surge class III and pollution options,
level 2 , unless stated otherwise without IExt 8 W/17 VA 8 W/13 VA 8 W/11 VA 8W
EC Certificate of Conformity no. 691.001
- with
CE marking conformity concerning options,
- EMC Guideline 89/336/EWG and without IExt 13 W/25 VA 13 W/20 VA 13 W/18 VA 13 W
- NS Guideline 73/23/EWG - with
Emitted interference, immunity to interference to EN 61 326, NAMUR options,
NE21 8/98 with IExt 26 W/45 VA 26 W/36 VA 28 W/35 VA 28 W

Weight, standard device


without options Approx. 1.2 kg
Colour
238 130 3)
Front module frame RAL 7037 278
Front surface RAL 7035
Material
Housing and front frame Polycarbonate, reinforced with
7
fiber glass
Relay
Front foil Polyester module
6DR2804Ć8A/B
Power supply connection
AC 115/230 V 3Ćpin earthed plug IEC 320/V
AC/DC 24 V Special 2Ćpin plug
Process signal connections Multiple screw terminal blocks,
cannot be confused when connecting, 223
for conductor crossĆsection 1.5 mm2 435 1)
(AWG 14)
Protective earth connection Earth screw
Panel cutĆouts
A rail can be mounted on the rear panel of the power supply. The rail is with studs without studs
included in the delivery of the coupling relay mode.

No. of CutĆout
devices width b

2 140 +1
1) Space required for removal of main circuit board. 3 212 +1
4 284 +1
2) Observe permitted ambient temperature when stacking without : :
intermediate spacing. : :
3) Arelay module containing 2 or 4 relay contacts (6DR2804Ć8A/Ć8B) : :
can be snapped onto the rear of the multiĆfunction unit, in which 10 716 +1
case the mounting depth increases by 130 mm.
4) Includes harmonic content.
5) Derived from L+, BA and AA.
6) Capacitive. Fig. 7/7 SIPART DR24 multiĆfunction unit and panel cutĆouts, dimensions

Siemens MP 31 · 2008 7/17


© Siemens AG 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Technical data

Technical data (continued) • A/D conversion


Method Successive approximation with
Power supply (continued)
> 120 measurements per input
Permitted and averaging over 20 or 16.67 ms
voltage Resolution 11 bit ≡ 0.06 %
dips1) Zero error ≤ 0.2 % of the measuring span
Stand. contr. Gain error ≤ 0.2 % of the measuring span
- without Linearity error ≤ 0.2 % of the measuring span
options, Effect of temperature
without IExt ≤ 90 ms ≤ 70 ms ≤ 55 ms ≤ 30 ms Zero ≤ 0.05 %/10 K
- with options, Gain ≤ 0.1 %/10 K
without IExt ≤ 80 ms ≤ 60 ms ≤ 50 ms ≤ 25 ms
- with options, • Parameters
with IExt ≤ 50 ms ≤ 35 ms ≤ 35 ms ≤ 20 ms
Adjusting
Test voltages Rate tA 2/3 (moreĆless)
(1 min) Precision
- primary - Time parameters ≤ ± 0.05 ğ troughout the complete temĆ
secondary AC 1.5 kV AC 500 V perature range
- primary - All others Absolute, depending on resolution
prot. cond. AC 1.5 kV AC 500 V
• Display technology
- secondary -
prot. cond. DC 700 V DC 700 V Digital dd1, dd2 displays 4½ digit, 7Ćsegment LEDs
Colour dd1 Green
Inputs and outputs, display technology dd2 Red
Digit height 7 mm
• Analog inputs AE1, AE2, AE3 and AE6 to AE11 Display range Adjustable startĆfull scale
(input module 6DR2800Ć8A) Numeric range -1999 to 19999
Decimal point Variable
Input signal range Refresh rate 1 to 100 cycles/display
Voltage 0/199.6 to 998 mV or 0/2 to 10 V Resolution 1 digit, but not better than
Current 0/4 to 20 mA A/D converter
Input impedance Display error Corresponding to A/D converter
Differential (voltage) 200 k and analog inputs
Differential (current) 49.9  ± 0.1 % Digital dd3 display 3Ćdigit, 7Ćsegment LEDs
CommonĆmode > 500 k Colour Yellow
CommonĆmode voltage 0 to 10 V Digit height 7 mm
Filter time constant 50 ms Display range Adjustable startĆfull scale
Effect of temperature Numeric range -199 to 999
Zero 0.05 %/10 K Decimal point Variable
Gain 0.1 %/10 K Refresh rate 1 to 100 cycle/display, variable
7 • Analog outputs AA1 to AA3
Resolution 1 digit, but not better than
A/D converter
Display error Corresponding to A/D converter
Rated signal range 0/4 to 20 mA and analog inputs
Operating range 0 to 20.5 mA or 3.6 to 20.5 mA Analog dA1, dA2 displays
Load voltage -1 to +18 V Colour dA1 Red
Max. inductive load ≤ 0.1 H dA2 Green
NoĆload voltage ≤ 26 V Display range LED array with 30 LEDs
Time constant 300 ms Signal range -199.9 to 199.9 %, variable
Overflow < -0.85 % of display range;
Residual ripple 900 Hz ≤ 0.2 % 1st LED flashes
Resolution ≤ 0.1 % > 100.85 % of display range;
Zero error ≤ 0.3 % of measuring span 30th LED flashes
Gain error ≤ 0.3 % of measuring span Resolution 1.7 % by alternate lighting of
Linearity error ≤ 0.05 % of measuring span 1 or 2 LEDs, the centre point of the
illuminated LEDs acting as a pointer
Load dependence ≤ 0.1 %
Refresh rate Cyclic
Effect of temperature
Zero ≤ 0.1 %/10 K
Gain ≤ 0.1 %/10 K

• Transmitter supply L+
Rated voltage 20 to 26 V
OnĆload current ≤ 100 mA, shortĆcircuit proof
ShortĆcircuit current ≤ 200 mA pulsed

• Digital inputs BE1 to BE4


Signal status 0 ≤ 4.5 V or open
Signal status 1 ≥ 13 V
Static destruction limit ± 35 V
Input impedance ≥ 27 k

• Digital outputs BA1 to BA8 (connected via WiredĆOR diodes)


Signal status 0 ≤ 1.5 V
Signal status 1 19 to 26 V
OnĆload current ≤ 50 mA
ShortĆcircuit current ≤ 80 mA pulsed

1) Load voltage of analog outputs thereby reduced to 13 V, L+ reduced


• Cycle time > 60 ms, user program dependent
to + 15 V and voltage on digital outputs drops to + 14 V.

7/18 Siemens MP 31 · 2008


© Siemens AG 2010, Edition March 2010

SIPART DR24 MultiĆfunction Unit


6DR2410-.
Ordering data

Ordering data
Documentation
Order No.
SIPART DR24 multi-function unit manual
SIPART DR24 multi-function unit - German www.siemens.com/sipartdr
72 x 144, - English www.siemens.com/sipartdr
basic unit with Mounting and instatallation instructions, www.siemens.com/sipartdr
- 3 analog inputs German/English
- 3 analog outputs
- 4 digital inputs Additional Instructions can be downloaded from Internet
- 8 digital outputs (www.siemens.com/sipartdr)
- user program memory
SIPART DR
PROFIBUS interface / Instructions
• for AC/DC 24 V power supply 6DR2410-4
(Description of the communication via PROFIBUS DP
• for switchable AC 230/115 V supply 6DR2410-5 with the controller SIPART DR19/20/21/22/24)
- German
- English
Input/output modules See Catalog Section 8
SIPART DR24
Analog signal module Serial SIPART 6DR24 Bus interface / Instructions
- for current input 0/4 to 20 mA or voltage (Description of the communication via RS 232, RS 485 or
inputs 0/0.2 to 1 V or 0/2 to 10 V PROFIBUS DP with the controller SIPART DR24)
(6DR2800Ć8J) - German
- English
- for resistance based sensor (R module)
(6DR2800Ć8R)
- for TC/RTD/R/mV signals, programmable
(UNI module) (6DR2800Ć8V)
- Reference junction terminal for TC, interĆ
nal (to be used in conjunction with UNI
module (6DR2805Ć8A)
- Measuring range connector for
I = 20 mA and U = 10 V
(to be used in conjunction with UNI moĆ Scope of supply
dule) (6DR2805Ć8J) The scope of supply of a DR24 multiĆfunction unit includes:
- with 3 analog outputs 0/4 to 20 mA and 1 multiĆfunction unit as ordered
3 binary inputs (6DR2802Ć8B) 1 power supply connector 115/230 V or a special connector for
- with 3 analog inputs 0/4 to 20 mA or 24 V AC/DC supply
0/0.2 to 1 V or 0/2 to 10 V (6DR2800Ć8A) 2 clamping elements, pluggable
- yĆhold module (6DR2802Ć8A) 1 CD-ROM with complete documentation

Switching signal module


- with 5 digital inputs (6DR2801Ć8C) Available ex-stores
7
- with 4 digital outputs and two digital Items marked are available exĆstores.
inputs (6DR2801Ć8E)
- with 2 relay outputs (6DR2801Ć8D)
Input/output modules and accessories
Coupling relay module The input/output modules are described in Catalog Section 8.
- With 4 relays (AC 250 V) (6DR2804Ć8A) Section 9 of the catalog contains details about software for parameterizing
- With 2 relays (AC 250 V) (6DR2804Ć8B) the multiĆfunction unit from a PC, interfacing to systems and the necessary
accessories (connectors, line drivers, etc.).
Interface modules
- For serial communications via RS 232
or RS 485 (6DR2803Ć8C)
- PROFIBUSĆDP module (6DR2803Ć8P)

Siemens MP 31 · 2008 7/19


© Siemens AG 2010

SIPART DR24 Input/Output Modules


6DR2410-.
Overview: applications

Analog signal modules SIPART DR24 Description


see Section 8,
8
Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Page
U/I module 6DR2800Ć8J AI4 AI5 - - - 8/3
3 x U/I module 6DR2800Ć8A - - - AI9/10/11 AI6/7/8 8/4
R module 6DR2800Ć8R AI4 AI5 - - - 8/5
Pt 100 module 6DR2800Ć8P (AI4)* (AI5)* - - - 8/6
TC module 6DR2800Ć8T (AI4)* (AI5)* - - - 8/7
UNI module 6DR2800Ć8V AI4 AI5 - - - 8/8
(TC/RTD/R/U/I)
yĆhold module 6DR2802Ć8A - - AO7 AO4 8/10
3AO/3DI 6DR2802Ć8B - - - AO7/8/9 AO4/5/6 8/11
module DI5/6/7 DI10/11/12

NEW
*) Use the UNI module 6DR2800Ć8V.

Switching signal modules SIPART DR24 Description


see Section 8,
8
Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Page
5 DI 6DR2801Ć8C - - - DI5/6/7/8/9 DI 8/12
10/11/12/13/14
2 relays 6DR2801Ć8D - - - DO9/10 DO13/14 8/13
4DO/2DI 6DR2801Ć8E - - - DO9/10/11/12 DO13/14/15/16 8/14
DI5/6 DI10/11
7
Interface module SIPART DR24 Description
see Section 8,
8
Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Page
SES module 6DR2803Ć8C 8/15
RS 232/SIPART bus - - Yes - -
RS 485 - - Yes - -
PROFIBUSĆDP module - - Yes - - 8/16
6DR2803Ć8P

NEW

Coupling relay module SIPART DR24 Description


can be installed on rear: see Section 8,
Page
with 4 relays 6DR2804Ć8A Yes 8/17
with 2 relays 6DR2804Ć8B Yes 8/17

Depending on the application, the follow- Description


ing can be used in conjunction with the see Section 8,
UNI module 6DR2800-8V: Page
Reference junction terminal 6DR2805Ć8A 8/8
Measuring range connector 6DR2805Ć8J 8/8