Sie sind auf Seite 1von 11

STRUCTURAL DESIGN CALCULATIONS

6.0 x 8.1 CAR PARKING SHADES - PROMER QATAR

STRUCTURAL DESIGN CALCULATIONS

25-Oct-09 0
Date Revision Description Calc. by Checkd. By Appd. By

REVISION HISTORY
AL JAIDAH AND SONS
TENTS AND UMBRELLA TRADING CO
INDUSTRIAL LINE -18 DOOR -54 QATAR

PROJECT : 6.0 x 8.1 CAR PARKING SHADES - PROMER QATAR

Checking of Fabric Sunshade

*** COMMERCIAL 95 PRE KNITTED SHADE CLOTH ***

3100
20
0

0.43
COMMERCIAL 95 PRE
KNITTED SHADE CLOTH

Y = C + SAG

S2 + C2 = Y2

S2 + C2 = ( C + 0.2 ) 2

S2 + C2 = C2 + 0.4 C + 0.04

S = ( 0.4 C + 0.04 )

X = C ln (( S + Y ) / C )

1.55 =C ln {( ( 0.4 C + 0.04 )) + ( C + 0.2 )} / C

BY TRIAL AND ERROR

TRY C = L2 / ( 8 * SAG )

C = 3.12 / ( 8 * 0.2 ) = 6m

1.55 =6 ln {( ( 0.4 * 6 + 0.04 )) + ( 6 + 0.2 )} / 6

1.55 » 1.54 OK

S = ( 0.4 * 6 + 0.04 )

S = 1.56

Y = 6 + 0.2

= 6.2

FABRIC TENSILE FORCE PER LINEAR METER

T = 0.43 * 6.2

= 2.66 kN/m

TENSILE STRENGTH OF FABRIC ( PRE CONTRAINT 1202S )

635 daN / 5 cm

6350 N / 50mm » 127 kN/m > 2.66 kN/m OK


AL JAIDAH AND SONS
TENTS AND UMBRELLA TRADING CO
INDUSTRIAL LINE -18 DOOR -54 QATAR

PROJECT : 6.0 x 8.1 CAR PARKING SHADES - PROMER QATAR

*** 20mm DIA WIRE ROPE ***

8100
50
0

2.66

Y = C + SAG

S2 + C2 = Y2

S2 + C2 = ( C + 0.5 ) 2

S2 + C2 = C2 + 1.0 C + 0.25

S = ( 1.0 C + 0.25 )

X = C ln (( S + Y ) / C )

4.05 =C ln {( ( 1.0 C + 0.25 )) + ( C + 0.5 )} / C

BY TRIAL AND ERROR

TRY C = L2 / ( 8 * SAG )

C = 8.12 / ( 8 * 0.5 ) = 16.4 m

4.05 = 16.4 ln {( ( 1.0 *16.4 + 0.25 )) + ( 16.4 + 0.5 )} / 16.4

4.05 » 4.03 OK

S = ( 1.0 * 20.2 + 0.25 )

S = 4.08

Y = 16.4 + 0.5

= 16.9

WIRE ROPE TENSILE FORCE

T = 2.66 * 16.9

= 44.95 Kn

TENSILE STRENGTH OF 20mm dia WIRE ROPE

= 216 kN > 44.95 kN OK


AL JAIDAH AND SONS
TENTS AND UMBRELLA TRADING CO
INDUSTRIAL LINE -18 DOOR -54 QATAR

PROJECT : 6.0 x 8.1 CAR PARKING SHADES - PROMER QATAR


AL JAIDAH AND SONS
TENTS AND UMBRELLA TRADING CO
INDUSTRIAL LINE -18 DOOR -54 QATAR

PROJECT : 6.0 x 8.1 CAR PARKING SHADES - PROMER QATAR

DESIGN REFERENCE

BS 5950 part 1: 2000 Structural use of Steel (Code of Practice for Design - Rolled and Welded Section)

BS 8110 part 1: 1997 Structural use of Concrete

CP3 chapter V : Loading, Part 2 : Wind loads

DESIGN CONSIDERATION

Compressive Strength, fc 30 N/mm2

Steel Yield Strength, fy 420 N/mm2

Soil Bearing Capacity 100 kPa ( Assumed; subject for soil investigation report )

Unit weight of concrete 24 kN/m3

Grade of Steel as per BS 5950 part 1 : 2000 S275

Grade 8.8 Bolt


8.1m 8.1m
Loading Consideration

DEAD LOAD

m
6
SHADENET + FRAMING = 0.05 kN/m2

WIND LOAD

Basic Wind Speed, V = 45 m/s

Height of Structure = 3.2 m

Topographical Factor, S1 = 1.0

( Ground roughness, Bldg size, Height = 0.68 ( table 3 of CP3 Chap V part 2)
above ground , country with many
windbreak, ), S2

Statistical Factor, S3 = 1.0

Design Wind Speed, Vs = VS1S2S3


= 45 * 1 * 0.68 * 1
= 30.6 m/s

Dynamic Pressure, q = 0.613 * 30.62 * 10-3


= 0.57 kN/m2

For a duopitch canopy roofs with maximum roof angle of 14.5°

Considering overall coefficient = + 0.4


= - 1.2

Reduction factor for free standing multibay canopy roofs (on second bay)
on Maximum ( + ) = 0.87
On Minimum ( - ) = 0.64
Canopy Wind Pressure, = 0.57*0.4*0.87 = 0.19 kN/m2
= 0.57*1.2*0.64 = 0.43 kN/m2
Member Section
Rafter Pipe = 4.0 mm x 2.5" dia pipe
AL JAIDAH AND SONS
TENTS AND UMBRELLA TRADING CO
INDUSTRIAL LINE -18 DOOR -54 QATAR

PROJECT : 6.0 x 8.1 CAR PARKING SHADES - PROMER QATAR

DESIGN OF CANOPY ROOF


Total surface area = 6 * 3.1 + (2+8.1)/2 * 3.1*2
= 49.91 m2

since the wind pressure coefficient on roof varies by zone total wind pressure reduce by 15% consider a 15% reduction of the total pressure on roof

Downward force due to wind and weight of canopy roof ( case 1 ) 8.1m
= 49.91 * 0.19 * 85% + 49.91 * 0.05
= 10.55 kN

1
3.
Upward force due to wind ( case 2 )

m
6
3.1
2.0m
= 49.91 * 0.43
= 21.46 * 85%
= -18.24 kN

X = ( 3.052 + 32 )1/2 0.78m


= 4.27 m
6m

L = ( 0.78 + 4.27 )
2 2 1/2

= 4.34 m

tan Ø = 0.78 / 4.27


= 10.3°

RAFTER PIPE
Section property of 2.5" mm dia pipe 4.0 mm thick

Area = 0.785 * ( 63.52 -55.52 )


= 747 mm2
radius of gyration = ( 63.52 + 55.52 )0.5 / 4
= 21 mm

Considering case 1, force equally resisted by rafter pipe member ( compression )


= (10.55 / 4) / sin 10.3
= 14.75 kN

Considering case 2, force equally resisted by rafter pipe member ( tension )


= (18.24 / 4) / sin 10.3
= 25.5 kN

Slenderness ratio = 4340 / 30


= 206
From table 24 a, BS 5950
Compressive Strength, rc = 40 N/mm2

Compression Resistance = 747 * 40 * 10-3


= 29.88 kN > 14.75 kN OK

Tension Resistance = 747 * 275 * 10-3


= 205 kN > 25.5 kN OK
AL JAIDAH AND SONS
TENTS AND UMBRELLA TRADING CO
INDUSTRIAL LINE -18 DOOR -54 QATAR

PROJECT : 6.0 x 8.1 CAR PARKING SHADES - PROMER QATAR


AL JAIDAH AND SONS
TENTS AND UMBRELLA TRADING CO
INDUSTRIAL LINE -18 DOOR -54 QATAR

PROJECT : 6.0 x 8.1 CAR PARKING SHADES - PROMER QATAR

BASE CONNECTION
350 mm x 350 mm x 20 mm thk base plate with 4 nos of M25 Grade 8.8 Anchor Bolt with embedment length of 600 mm

Bolts subjected to tension due to Moment

50.89 * 106 = 2 * T * 220* 10-3

T = 115.6 kN

T = 15.37 / 4
= 3.84 kN

total = 119.4 kN

Using 25 mm dia Grade 8.8 bolt

Capacity = 0.75 * p * 252/4 * 450 * 10-3


= 165.5 kN > 119.4 kN OK

Embedment length = 119.4 * 103 / ( p * 25 * 0.5 *√30 )


= 555 mm < 600 mm OK

Plate bending moment = 119.4 * 2 * 0.04


= 9.55 kNm

Section Modulus Required = 9.55 * 106 / 275


= 34734 mm3 » 34.7 cm3

considering base plate

section modulus, Sx = 350 * 202 / 6


= 23333 mm3
= 23.3 cm3 < 34.73 cm3 not OK

Section property (section A - A) with 12 mm gusset plate


N. A. ( x ) = 126 mm 12

Sec. Moment of area, Ix = 9606151 mm4


x
150
Section Modulus, Sx = 405867mm3
= 40.5 cm3 > 34.73 cm3 OK
18
Welding Capacity of 10mm fillet weld
350
Capacity per 1mm = 10 * 0.7 * 220
SECTION A-A
= 1540 N/mm

350
40 270 40
40

4 nos. 25mm dia


grade 8.8 bolt
10mm weld
350 x 350 x 20mm thk
STEEL PLATE
270
350

6.6" dia x 11mm thk


CHS COLUMN

12mm thk
40

STIFFENER PLATE
AL JAIDAH AND SONS
TENTS AND UMBRELLA TRADING CO
INDUSTRIAL LINE -18 DOOR -54 QATAR

PROJECT : 6.0 x 8.1 CAR PARKING SHADES - PROMER QATAR

Considering 1.6m x 1.6m x 1200mm thick Concrete Footing

Weight of Footing = 1.6 * 1.6 * 1.2 * 25


1600
= 56.25 kN

1600

1200

1600 5.27 kN 5.27 kN

* Case 1 Due to Downward Load 6m


Moment = 5.27 * 6
= 31.62 kNm
Soil Bearing Pressure Check
Maximum Pressure = ( 76.8+ 5.27) / (1.6 * 1.6) + 6 * 31.62 / (1.6 * 1.62)
= 78.38 kN/m2 < 100 OK

* Case 2 Due to Upward Load


Stability Check of Footing
9.12 kN 9.12 kN
Overturning Moment = 9.12 * 6
= 54.72 kNm
Resisting Moment = ( 76.8 - 9.12 )* 0.8 6m
= 54.15 kNm
due to passive pressure = 3*18*0.9*1.6*.9/2*.9/3
= 10.49 kNm
F.S. Overturning = (54.14+10.49) / 54.17
= 1.18 > 1 OK

Reinforcement for 1200mm thk base for cracking


Minimum each face, As = 0.13 * 250
= 325 mm2
Provided T12 @ 150 ( 757 mm2 )