HEAT TRANSFER
EQUIPMENT
Prepared by:
Group 12
Members:
Cantos, Jazer Mari M.
Catapang, Cathy Mae B.
De Castro, Lyniel Jan S.
De Castro, Nica Mariel M.
ChE-4201
Submitted to:
Introduction
The transfer of heat to and from process fluids is an essential part of most chemical processes.
Heat transfer equipment are found to be useful in a wide range of industries. They can be broadly
defined as equipment used for transfer of heat from a hot medium to cold medium. Heat exchanger
design and structure of these equipment varies a lot depending on the application where they are
used and the heat transfer media involved. The most commonly used type of heat-transfer
equipment is heat exchanger. Heat exchangers are devices used to transfer heat between two or
more fluid streams at different temperatures. Heat exchangers find widespread use in power
generation, chemical processing, electronics cooling, air-conditioning, refrigeration, and
automotive applications.
The term heat in physics, refers to the transfer of energy from one part of a substance to another,
or from one object to another, because of a difference in temperature. Heat flows from a substance
at a higher temperature to a substance at a lower temperature, provided the volume of the objects
remains constant. Heat does not flow from a lower to a higher temperature, unless another form of
energy transfer, work, is also present.
Types of Heat
If the heat energy is added to a substance, the motion of the molecules increases creating more
heat and thereby increasing the temperature, nearly all modern chemical process, heat is either:
needed to make the reaction between the substances happen, or is produced during a chemical
reaction.
1. Latent heat is the energy absorbed by or released from a substance during a phase change
from a gas to a liquid or a solid or vice versa.
2. Sensible heat is the energy required to change the temperature of a substance with no phase
change.
Heat Transfer
It refers to the process by which energy in the form of heat is exchanged between objects, or parts
of the same object, at different temperatures. Heat is generally transferred by radiation, convection,
or conduction, processes that may occur simultaneously.
1. Conduction is the only method of heat transfer in opaque solids. The mechanism of
conduction in solids is believed to be partially due to the motion of free electrons in the
solid matter.
2. Convection is where heat travels through liquids and gases.
3. Radiation consists of invisible energy waves, which are able to pass across a space. Unlike
the aforementioned methods, it does not require any material to be present between the hot
and cold surface.
Heat Exchangers
Process equipment and streams will need to be heated or cooled. One way to reduce consumption
of utilities is to exchange heat between these streams. For example, if a product stream requires
cooling, the excess heat can be used to preheat a feed stream that requires heating by using an
appropriate heat exchanger. Here the costs of an additional heating and additional cooling unit are
eliminated, and replaced by the cost of a heat exchanger.
Exchanger
all types of equipment in which heat is exchanged; but, often used specifically to denote equipment
in which heat is exchanged between two process streams.
Heaters and Coolers – process fluid is heated or cooled by a plant service stream.
Vaporizer – process stream is essentially completely vaporized
Reboiler – heat exchanger associated with a distillation column
Evaporator – used to concentrate a solution
Fired Exchanger – used for exchangers heated by combustion gases
Unfired Exchanger- prevents the corrosion of the equipment
Types of Reboilers
1. Kettle Reboilers are often used as a steam generator. Pool boiling is used in kettle
reboilers. In pool boiling, agitation occurs through bubbling and natural convection.
2. Thermosiphon Reboilers use flow boiling. In flow boiling, agitation occurs through
bubbling and forced convection at high velocities. They can be located at a height below
the column sump.
3. Stab-in reboilers are essentially the heat exchange tube bundle fitted inside a sump. In this
case, the sump behaves in a similar capacity to a kettle reboiler, and mechanism of pooling
is again pool boiling.
Types of Condenser
1. Total Condenser- all the vapor that enters is condensed as a film on the heat transfer
surface.
2. Partial Condenser- not all of the vapor that enters is condensed. This allows for vapor-
liquid separation.
Types of Heaters
1. Fired Heaters- Fired heaters are used for heating up to high temperatures. They are able
to reach these high temperatures because they generate energy by combustion of natural
gas, fuel oil, or process off-gas.
2. Electric Heaters- heat is generated by running electricity through wires of high resistance.
Heat is exchanged with fluid passed over axially through MgO insulation.
3. Steam Generators- Often, high-pressure steam is generated in boilers. As it moves
through a plant, it can be expanded in turbines to recover energy. Most plants use more
than one level of steam.
Types of Coolers
1. Air Coolers- Advantages of air coolers are that they do not require additional
infrastructure, and air is free so that the only operating cost is the electricity for the fans.
Additionally, it is easy to add extra capacity for a higher duty.
2. Water Coolers- Water coolers require extensive infrastructure (pipes, cooling towers,
water treatment) in order to provide water for cooling. Depending on the location, cheap
water is not always available, and it is expensive to add capacity to handle an increased
duty.
3. Refrigeration- Refrigeration is used for very low temperatures (<40C).
1. Capital costs - Large heat exchangers can perform heat transfer for even very small temperature
differences, but they come at a higher cost.
2. Operating costs - In shell and tube exchangers, small diameter tubes can be used to increase the
surface area available for heat transfer. But, small diameter also means higher pressure drop across
the tubes leading to higher operating costs.
3. Materials - Depending on the type of fluid and its corrosiveness, a suitable material has to be
chosen for construction of a heat exchanger, even if does not assure maximum heat transfer.
4. Fluid phase - Different types of exchangers are used for different phases of fluid and even phase
changes e.g. condensers, boilers, air cooled exchangers etc.
Design Procedure
(Heat Exchanger)
How to design a heat exchanger?
For sizing a heat exchanger, several thermal phenomena should be considered first:
Forced convection of both fluids: Convection is the transfer of heat between a wall and a
flowing fluid, both having different temperatures. In the case of heat exchangers, it is called
forced convection as it is caused by artificial circulation (pumps, turbines, fans...)
Conduction: This is the transfer of heat which occurs naturally through the walls, plates
and tubes. This phenomenon is based on the principle of thermal agitation without
movement of material.
Thermal radiation which could be considered as negligible
The design of a heat exchanger addresses mainly three phases:
2.Thermal design
2.a. Validation of the thermal program
Once the technological choices made, we will proceed to the design of the heat exchanger , i.e.
determining its power, size and geometry. It is first necessary to validate the data of the thermal
program, with the following 3 formulas:
First, LMDT (Logarithmic mean temperature difference) shall be calculated. The LMDT is the
logarithmic average of the temperature differences at each end of the heat exchanger:
Once LMDT and Power have been calculated, the heat exchanger calculation can be done as
per the following formula:
K: Heat Transfer Coefficient in KW/°C/m2 that is specific to each type of equipment and given by
the manufacturer.
S : Heating area in square meters.
When the heat exchanger is designed, the heat exchanger pressure drop can be calculated with
different correlations determined by the characteristics of the exchange surfaces.
Types of Heat Exchangers
Nomenclature
Process (Thermal) Design Procedure
Shell and tube heat exchanger is designed by trial and error calculations. The main steps of design following
the Kern method are summarized as follows:
Step #1. Obtain the required thermophysical properties of hot and cold fluids at the caloric temperature or
arithmetic mean temperature. Calculate these properties at the caloric temperature if the variation of
viscosity with temperature is large.
Step #2. Perform energy balance and find out the heat duty ( Q ) of the exchanger.
Step #3. Assume a reasonable value of overall heat transfer coefficient (Uo, assm).
Step #4. Decide tentative number of shell and tube passes ( p n ). Determine the LMTD and the correction
factor FT. FT normally should be greater than 0.75 for the steady operation of the exchangers. Otherwise it
is required to increase the number of passes to obtain higher FT values.
Step #5. Calculate heat transfer area (A) required:
Step #6. Select tube material, decide the tube diameter its wall thickness (in terms of
BWG or SWG) and tube length (L). Calculate the number of tubes (nt) required to provide the heat transfer
area (A):
Step #7. Decide type of shell and tube exchanger (fixed tube sheet, U-tube etc.). Select the tube pitch (PT),
determine inside shell diameter (Ds) that can accommodate the calculated number of tubes (nt). Use the
standard tube counts table for this purpose.
Step #8. Assign fluid to shell side or tube. Select the type of baffle (segmental, doughnut etc.), its size (i.e.
percentage cut, 25% baffles are widely used), spacing (B) and number. The baffle spacing is usually chosen
to be within 0.2 Ds to Ds.
Step #9. Determine the tube side film heat transfer coefficient (hi) using the suitable form of Sieder-Tate
equation in laminar and turbulent flow regimes.
Step #10. If go the next step # 11. Otherwise go to step #5, calculate heat transfer area
(A) required using Uo,cal , and repeat the calculations starting from step #5.
Step #11. Calculate % overdesign. Overdesign represents extra surface area provided beyond that required
to compensate for fouling. Typical value of 10% or less is acceptable.
A = design area of heat transfer in the exchanger; Areqd = required heat transfer area.
Step #12. Calculate the tube-side pressure drop ( PT ): (i) pressure drop in the straight section of the tube
(frictional loss) ( Pt ) and (ii) return loss ( Prt ) due to change of direction of fluid in a „multi-pass
exchanger‟. Total tube side pressure drop: PT = Pt + Prt..
Step #13. Calculate shell side pressure drop ( PS ): (i) pressure drop for flow across the tube bundle
(frictional loss) ( Ps ) and (ii) return loss ( Prs ) due to change of direction of fluid. Total shell side pressure
drop: PS = P s + P rs (1.9) If the tube-side pressure drop exceeds the allowable pressure drop for the
process system, decrease the number of tube passes or increase number of tubes per pass. Go back to step
#6 and repeat the calculations steps. If the shell-side pressure drop exceeds the allowable pressure drop, go
back to step #7 and repeat the calculations steps.
Step #15. Upon fulfillment of pressure drop criteria, go mechanical design.
Evaporator
Single effect evaporator calculations are pretty straight forward. The latent heat of condensation
of the steam is transferred through the heating surface to vaporize water from a boiling solution.
Therefore, two enthalpy balance equations are required to in order to calculate the rate of solvent
vaporization and the rate of required input heat.
Generally, it is possible to solve the energy and the material balance equations analytically by a
sequential approach. The following assumptions are made to develop the mass and energy balance
equations: -
From the enthalpy data of the solutions, steam and condensate, the rate of heat input or the rate of
steam flow can be calculated.
Calculate the tube-side and shell-side pressure drop using the method discussed during design of
shell & tube exchanger from specified values of the tube length, diameter and the tube layout. If
the pressure drop value is more than the corresponding allowable pressure drop, further
adjustments in the heat exchanger configuration will be required.
Typically, multiple effect evaporator calculations require a trial-and-error approach as many of the
necessary properties depend on unknown intermediate temperatures. Often the heat transfer areas
in all effects are considered to be equal. Use of equal size evaporator in all effects, reduces the cost
of equipment significantly. In a typical evaporator problem, you are provided with the supply
pressure and temperature of steam, the operating pressure of the final effect, the feed and
concentrations. The designer is often required to have trial estimates of overall heat transfer
coefficients. The overall strategy is to estimate intermediate temperatures. The energy and material
balance equations are solved sequentially to determine the heat transferred in each effect and the
heat transfer area. If the areas are not equal, the calculation is repeated to revise the intermediate
temperatures and the procedure is repeated till the heat transfer area in all effects are equal.
Condenser
Condenser design
The design of condenser is similar to a typical shell and tube exchangers. A condenser must have
a vent for removal of non-condensable gas. The non-condensable gas decreases the heat transfer
rate. Condenser usually use a wider baffle spacing of B D s (ID of shell) as the allowable pressure
drop in shell side vapor is usually less. Vertical cut-segmental baffles are generally used in
condensers for side-to-side vapor flow and not for top to bottom. An opening at the bottom of the
baffles is provided to allow draining of condensate.
Mean temperature difference
The condensation occurs almost at a fixed temperature (isothermally) at constant pressure for a
pure saturated vapor compound. The logarithmic mean temperature difference can be used for
condenser design.
Calculation of heat transfer co-efficient during condensation
Calculation of tube side heat transfer co-efficient (hi): The calculation of heat transfer co-efficient
for the cold fluid (coolant) can be performed similarly as discussed in design of shell and tube heat
exchanger (heat transfer without phase change). Here it is assumed that the coolant flows the in
tube side and the condensing saturated vapor flows in the shell side. If the condensation occurs in
the tube.
Miscellaneous Rules of Thumb
1. For fixed tubesheet design of shell and tube heat exchangers don’t allow too high a temperature
difference between tubeside and shellside without providing a shellside expansion joint. The
author has seen 70°F (one company) and 100°F (another company) used as this limit. An easy way
to calculate the maximum stress is as follows:
a. Assume the tubes are at tubeside bulk temperature and the shell is at shellside bulk
temperature.
b. Calculate the elongation of tubes, if unhampered, and shell, if unhampered, starting at
70°F and using the respective coefficients of expansion.
c. If the tubes would have grown more or less than the shell, the difference will set up stress
in both members, one in tension and the other in compression.
d. Assume the deformation (strain) in each member is inversely proportional to its cross-
sectional area. In other words, the fraction of the total strain in inched inch of length will
be proportionally more for the member (tubes or shell) having the smallest cross section.
e. For each member, multiply its strain by Young’s modulus (Modulus of Elasticity) in
consistent units to get stress. Strain is dimensionless so Young’s modulus in lb/in’ will
yield stress in Ib/in’.
f. Compare this with the maximum allowable stress for the material used.
g. The tensile and compressive modules for steel are essentially the same.