Beruflich Dokumente
Kultur Dokumente
DOC-131 DOC-131
Motor
TER2
U V W
Earth Plate
MB
Part Wiring
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2
Page 3/29
FOD Start-up Routine
Overseas Support Team Date Mar. 2009
Safety
Part Wiring
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2
Page 4/29
FOD Start-up Routine
Overseas Support Team Date Mar. 2009
1.4 Governor
1.4.1 Governor Connection
GRS(Over Speed Switch) : 1 & 2 Pin
GSS(Governor Slack Switch) : 4 & 5 Pin
OBS(Oil Buffer Switch) : 7 & 8 Pin
Bottom of controller is
positioned at 300mm height
from top floor level.
Junction box
Part Wiring
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2
Page 6/29
FOD Start-up Routine
Overseas Support Team Date Mar. 2009
Junction box
500
500
Part Wiring
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2
Page 7/29
FOD Start-up Routine
Overseas Support Team Date Mar. 2009
5200~5600mm
Plastic anchor
5200~5600mm
Plastic anchor
Rubber band
(For fixing cables)
700~1000mm
Junction Box
500mm
Plastic anchor
500mm
Cable Hanger
Cable Hanger
Part Wiring
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2
Page 8/29
FOD Start-up Routine
Overseas Support Team Date Mar. 2009
A B C
EVV Cable
Connect plugs (Y1,
Y2, Y3, & Y4) to caps
of DOM-160 PCB
Junction Box
Car side
Controller side
Safety
Part Wiring
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2
Page 11/29
FOD Start-up Routine
Overseas Support Team Date Mar. 2009
GTC
Electric Outlet
Rubber Band
Door switch
Within 400~500mm
Part Wiring
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2
Page 13/29
FOD Start-up Routine
Overseas Support Team Date Mar. 2009
1 of DHG-162
Top floor (1 floor with 1 of DHG-162)
- Install Junction Box at 300mm higher
from the level of the floor
1 of DHG-162
Bottom floor (2 floor with 1 of DHG-162)
- Install Junction Box at 3500mm higher
from the level of lower floor
Part Wiring
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2
Page 14/29
FOD Start-up Routine
Overseas Support Team Date Mar. 2009
HI1
HI2
HVF
HP HDC
HUC
HD
HC2
HU
HC1
HF2
HA
HF1
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4
Electric outlet
Electric outlet
Controller
EVV 2C
COVV 3C
GTC
GSS Car side
Controller
GRS-04
GRS-05 GTC
GSS C'WT side
Safety Box
Safety
Part Wiring
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2
Page 21/29
FOD Start-up Routine
Overseas Support Team Date Mar. 2009
b. Assemble the RPD magnet and install them at the landing sill of all floors.
Part Wiring
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2
Page 22/29
FOD Start-up Routine
Overseas Support Team Date Mar. 2009
d. As referring above ‘c’ assemble the RPD sensor before car panel assembling. Its vertical
allowable error is ±1mm
f. In case of non –stop service floor, Adjust the distance from RPD sensor to RPD magnet
to be 15mm±7 mm.
1.8.4 Connect Light & P.F Light to LIG & PLG housing of CONN PCB in Apparatus Box
1.8.5 Connect Car Door Switch to CDS housing of CONN PCB in Apparatus Box
TERM2-10
b. MSB
P48V 13-10
13-04
13-05
J2-06
Y1-03
Part Wiring
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2
Page 28/29
FOD Start-up Routine
Overseas Support Team Date Mar. 2009
1.8.8 Connect CPI to CPI housing of CONN PCB in Apparatus Box in case CPI is located
outside OPB
1.8.9 Connect Emergency Exit Switch to EES housing of CONN PCB in Apparatus Box
1.8.10 Connect Safety Catch Switch to SCS housing of CONN PCB in Apparatus Box
1.8.11 Connect Wall Socket Light to WS housing of CONN PCB in Apparatus Box
Part Wiring
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2
Page 29/29
FOD Start-up Routine
Overseas Support Team Date Mar. 2009
1.8.13 Connect Safety Edge Shoe to SES housing of CONN PCB in Apparatus Box
Disconnect JP7 (jumper) on CONN PCB in case of 2 Safety Edge Shoe.