Sie sind auf Seite 1von 4

Design Specifications

DS-M/T 3750A
August, 1998
Model 3750A (Supersedes issue dated April, 1997)

Ar-MiteTM Low Flow Armored Flowmeter


• Wetted metal parts 316L stainless steel
• Type NEMA 4X aluminum housing, epoxy
painted
• Front panel mounting
• Optional hermetically sealed reed switch
alarm
• Interchangeable scale - without removing
the meter from the pipeline

DESCRIPTION
The Brooks® Ar-MiteTM is a reliable, low flow metal tube
flowmeter with 316L stainless steel wetted parts. The
magnetically coupled indicator provides a highly reliable
method of indication. The reed switch alarm uses a
unique two sensor design, eliminating the need for
"biased" reed switches which can affect meter
performance. This model is a practical and economical
approach to low flow rate indication for high pressure
and difficult to handle fluids.
Model M/T 3750A
SPECIFICATIONS

WARNING
Do not operate this instrument in excess of the
Materials of Construction:
specifications below. Failure to heed this warning
can result in serious personal injury and/or damage
to the equipment. Meter Tube Assembly
316L stainless steel
Scales
Length - 55mm, nominal Clean-out Plug, Float Stop
Types - Direct reading scales in engineering units for air or 316L stainless steel
water at standard conditions; millimeter reference with
air or water calibration data sheet. Housing
Epoxy painted aluminum
Connections
1/4" female NPT, horizontal inlet and outlet Float
316L stainless steel (integral magnet)
Accuracy
±5% full scale
Valve Plug or Optional Valve
Repeatability 316L stainless steel (316 SS for NRS Valves)
1% full scale
O-rings
Ratings Standard: Viton®; Optional: Buna-N, Ethlylene Proplylene,
Maximum fluid pressure: 1500 psig (103 bar) Kalrez®, Teflon® (without valve)
Optional maximum operating pressure: 4000 psig (276
bar) no valve Float Stop Spring
Maximum fluid temperature: 400°F Inconel® 625

1
Figure 1 Dimensions

Figure 2 Mounting Dimensions

2
Meter Dimensions
Refer to Figures 1 and 2

Ordering Information and Model Code


Refer to Table 1

Capacities
Flow Range
Meter Water Air*
Size gph lph scfh slpm
1 0.035-0.35 0.13-1.3 0.2-2.2 0.1-1.0
2 0.095-0.95 0.36-3.6 0.5-5 0.2-2.3
3 0.28-2.8 1-10.6 1.3-13 0.6-6.0
4 0.55-5.5 2.1-21 2.4-24 1.1-11
5 1.1-11 4.2-42 5.5-55 2.6-26
6 2.6-26 10-100 12-120 5.6-56
*Air flows are at 70°F (21.1°C) and 14.7 psia (101.3kPa)

Optional Equipment FM
Cartridge Valve or Precision NRS Valve on inlet
Integrally piped flow controller (See DS-8800, 8900) APPROVED
Special scales
Reed Switch Alarm Figure 3 Model MT 3750A with Alarm

Specifications - Reed Switch Alarm Nonincendive, FM and CSA/NRTL/C Approved, CL l, ll, lll,
High, low or dual setpoints, latched output, over full range. Div. 2, Gps A-G
NEMA 4X Enclosure Max. Voltage 30 Vdc*
Maximum Fluid Temperature: 250°F Max. Current 100 mA*
Maximum Ambient Temperature: 125°F Max. Contact rating 3 Watts* (product of current and
voltage)
Intrinsic Safety, FM and CSA/NRTL*/C Approved, CL l, ll, *maximum switch contact specifications
lll, Div. 1, Gps A-G Specifications Subject to Change Without Notice
Entity Parameters, Vmax=30V, lmax=100mA, Li=0, Ci=0
FM and CSA/NRTL/C Approved IS Barrier required or FM TRADEMARKS
and CSA/NRTL/C Approved Power Supply/Relay Ar-Mite ................ Brooks Instrument Division, Emerson Electric Co.
Isolator available from Brooks. Brooks ................. Brooks Instrument Division, Emerson Electric Co.
*Canadian Standards Association/Nationally Recognized Testing Inconel ................................................. Inco Alloys International, Inc.
Laboratory accredited by the US Occupational Safety and Health Kalrez ........................................................... DuPont Dow Elastomers
Administration (OSHA) and Canada. CSA, FM, UL, ETL are all Teflon ................................................. E.I. DuPont de Nemours & Co.
currently approved NRTL test laboratories. Viton ............................................................. DuPont Dow Elastomers

Figure 4 Typical Alarm Circuit

3
Table 1 Ordering Information and Model Code
MODEL ARMORED PURGE METER
3750A 55 MM
| CODE METER SIZE
| 1 SIZE 1
| 2 SIZE 2
| 3 SIZE 3
| 4 SIZE 4
| 5 SIZE 5
| 6 SIZE 6
| | CODE MATERIALS OF CONSTRUCTION
| | A 316L STN. STL. - VITON O-RINGS
| | B 316L STN. STL. - TEFLON O-RINGS (NO VALVE UNITS ONLY)
| | C 316L STN. STL. - BUNA O-RINGS
| | D 316L STN. STL. - KALREZ O-RINGS
| | E 316L STN. STL. - EPM O-RINGS
| | F 316L STN. STL. - ALL WELDED, MUST BE NO VALVE UNIT (VALVE CODE A) AND HIGH PRESSURE (OPTION CODE M)
| | | CODE VALVE/CONTROLLER CONFIGURATION
| | | A NO VALVE OR CONTROLLER
| | | B LOW CARTRIDGE VALVE ON INLET TYPICAL FOR SIZES 1 & 2 (SEE NOTE 1)
| | | C MEDIUM CARTRIDGE VALVE ON INLET TYPICAL FOR SIZES 3 & 4 (SEE NOTE 1)
| | | D HIGH CARTRIDGE VALVE ON INLET TYPICAL FOR SIZES 5 & 6 (SEE NOTE 1)
| | | E MOUNTED TO 8802/8902 STN. STL. FLOW CONTROLLER W/ TEFLON DIAPHRAGM
| | | F MOUNTED TO 8805 STN. STL. FLOW CONTROLLER W/ TEFLON DIAPHRAGM
| | | G MOUNTED TO 8802/8902 BRASS FLOW CONTROLLER W/ TEFLON DIAPHRAGM
| | | H SIZE 1 NRS VALVE ON INLET
| | | J SIZE 2 NRS VALVE ON INLET
| | | K SIZE 3 NRS VALVE ON INLET
| | | L SIZE 4 NRS VALVE ON INLET TYPICAL FOR SIZES 1 & 2 (SEE NOTE 1)
| | | M SIZE 5 NRS VALVE ON INLET TYPICAL FOR SIZE 3 (SEE NOTE 1)
| | | N SIZE 6 NRS VALVE ON INLET TYPICAL FOR SIZES 4, 5 & 6 (SEE NOTE 1)
| | | P VALVE CAVITY ON INLET (NO VALVE ASSEMBLY OR PLUG)
| | | Q MOUNTED TO 8802/8902 STN. STL. FLOW CONTROLLER W/ BUNA-N DIAPHRAGM
| | | R MOUNTED TO 8805 STN. STL. FLOW CONTROLLER W/ BUNA-N DIAPHRAGM
| | | S MOUNTED TO 8802/8902 BRASS FLOW CONTROLLER W/ BUNA-N DIAPHRAGM
| | | | CODE SCALE INSCRIPTION
| | | | B MILLIMETER
| | | | C % OF MAXIMUM FLOW - AIR @ STP
| | | | D % OF MAXIMUM FLOW - WATER
| | | | E 0 - 100 , LINEAR
| | | | F SCFH AIR @ STP
| | | | G GPH WATER
| | | | H SLPM AIR @ STP
| | | | J LPH WATER
| | | | K SPECIAL INSCRIPTION , UNCALIBRATED
| | | | L SPECIAL GAS INSCRIPTION , CALIBRATED
| | | | M SPECIAL WATER INSCRIPTION , CALIBRATED
| | | | N SPECIAL OIL INSCRIPTION , CALIBRATED
| | | | | CODE CONNECTION ORIENTATION
| | | | | 1 INLET & OUTLET - BACK
| | | | | | CODE ELECTRICAL OUTPUT
| | | | | | A NONE (INDICATOR ONLY)
| | | | | | B REED SWITCH ALARM, METER MOUNTED ENCLOSURE
| | | | | | | CODE CONNECTION TYPE
| | | | | | | 1 1/4" FEMALE NPT, INTEGRAL
| | | | | | | 2 1/4" MALE COMPRESSION
| | | | | | | | CODE ACCESSORIES
| | | | | | | | A NONE
| | | | | | | | B FLUSH PANEL MOUNTING BEZEL (NOT AVAIL. W/ALARM)
| | | | | | | | C NO BROOKS IDENTIFICATION
| | | | | | | | D DEGREASE FOR OXYGEN SERVICE PER J834Z169AAA
| | | | | | | | E SPECIAL CLEANING PER J834Z172AAA
| | | | | | | | F PER NACE SPEC. MR-01-75
| | | | | | | | G CALIBRATE FOR NIST TRACEABILITY
| | | | | | | | H 115V RELAY, 1 CHANNEL
| | | | | | | | J 220V RELAY, 1 CHANNEL
| | | | | | | | K 115V RELAY, 2 CHANNEL
| | | | | | | | L 220V RELAY, 2 CHANNEL
| | | | | | | | M HIGH PRESSURE (4000 PSIG), MUST BE NO VALVE UNIT (CODE A)
| | | | | | | | |
3750A 1 A B F 1 A 1 A TYPICAL MODEL CODE

NOTE 1: VALVE SELECTION IS BASED ON AIR AT 10 PSIG INLET. SEE DS-BLIV OR DS-8503 FOR ADDITIONAL INFORMATION.

ISO 9001
QUALITY SYSTEM
Certificate of Conformity
The Quality System at Brooks Instrument
conforms to the quality standards set
forth in ISO 9001.

Das könnte Ihnen auch gefallen