Sie sind auf Seite 1von 1

AHMED GLASS INDUSTRIES Pvt Ltd

Date : 21-10-2018
OPERATION DURABILITY TEST

DURABILITY TEST TSF-5309G STANDARDS


+80
TEMPERATURE LIFTING LOAD STOP LOWERING LOAD STOP REMARK
±2 °C
REAR SEAT W/R 1000 2-5 Sec 0.5- 1 Sec 30 Sec 2-5 Sec 0.5-1 Sec 30 Sec

Sample No # 2 Testing Data

Cycle Time 70 Sec

Set
Test Start 4:00:00 PM Temperatur 80 °C
Time 20-Oct e
11:44:00
Test End
AM
time
21-Oct

Instrument
Vacuum
Total cycle 1000 Used For
Cabinet
temprature

Design new circuit by using PLC and


programmed it as per standard.

Sample No # 2

PROCEDURE OF CHANNEL ASSMBLY.


PICTURE

Assembled By Using liquid Soap

AGI Observation
Observe Part Picture

OK
Process Sample Found OK. No shifting OF Channel & Filler observed after completing 1000 cycles.
Result Motor and lifting arm found ok..

Prepared By Checked By Approved By

Kashan Zia M.Taha Khan Sohail Saquib