Ventilation

Product catalogue 2019


for professionals

Including
new
Modular L
Fresh air for the residential and commercial sector
Heat reclaim ventilation and air handling applications
MODULAR L (SMART)

D-AHU MODULAR R

2
INTRO
Table
of contents
The widest ventilation range on the market 4

ERV / HRV - Heat reclaim ventilation units 9


›› Modular L Smart (ALB-RBS/LBS) NEW
›› VAM-FC/J / VKM-GB(M)


Condensing units for AHU 29

Options & accessories  42

Tools and platforms 49

Technical drawings 57

3
ARGUE CARDS

5 reasons
why Daikin’s ventilation range
is unique in the market

1 Market leading controls


& connectivity
›› Interlock of ventilation and air conditioning system
• Control ERV/HRV and air conditioning from
the same controller
• Aligns the operation mode between the systems to
save energy
›› Easy integration in the total solution
• Online control and monitoring via the Daikin Cloud Service
• Full portfolio integration in the intelligent Touch Manager,
Daikins cost-effective mini BMS
›› User-friendly controller with premium design
• Intuitive touch button control

21°C

2 Unique installation benefits


›› Integrates seamlessly in the Daikin total solution,
ensuring a single point of contact
›› Total fresh air solution with Daikin supplying both the
VAM/Modular L Smart and the electrical heater
›› Daikin AHU and condensing unit connect Plug & Play thanks to same
pipe diameters, factory mounted controls, expansion valves, etc.

4
INTRO
3 High energy efficiency Up to
›› Energy recovery of up to 92%, reducing running costs
›› Free nighttime cooling using fresh outside air 92%
›› Inverter driven centrifugal fans heat recovery
›› ErP compliant

4 Best comfort
›› Wide range of units to control fresh air and humidity
›› Wide range of optional filters to suit the application available up to ePM1 80% (F9)
›› Special paper heat exchanger recovers heat and moisture from outgoing air to
warm up and humidify incoming air to comfortable levels (VAM, VKM)

5 Top reliability
›› Most extensive testing before new units leave the factory
ErP
›› Widest support network and after sales service COMPLIANT
›› All spare parts available in Europe

COGNITIVE FUNCTION SCORES …


Did you know?

CO2 levels and ventilation rates all have significant,


independent impacts on cognitive function: + 61% + 101%
IN GREEN BUILDING IN ENHANCED
CONDITIONS GREEN BUILDING CONDITIONS

5
Widest range of DX integrated
ventilation on the market

Daikin offers a variety of solutions from small heat recovery


ventilation to large-scale air handling units for the provision of fresh
air ventilation to homes, or commercial premises.

Ventilation solutions

Daikin offers state-of-the-art ventilation solutions that can easily be integrated


into any project:
›› Unique portfolio within DX manufacturers
›› High-quality solutions complying with the highest Daikin quality standards
›› Seamless integration of all products to provide the best indoor climate
›› All Daikin products connected to a single controller for complete control of the
HVAC system.

Heat Reclaim Ventilation - Ventilation with heat recovery as standard

Our heat recovery units recover sensible heat (Modular L / Modular L Smart) and
latent heat (VAM/VKM), substantially reducing the load on the air conditioning
system up to 40%.

Ventilation with DX connection - Control over fresh air temperature

Daikin offers a range of inverter condensing units to be used in combination with


Daikin AHUs for ultimate control over the fresh air. There are 4 control possibilities
when combining AHU and Daikin outdoor units hence offering all the required
flexibility for any installation. Indoor units can be combined to the same outdoor
unit to reduce the installation costs. For false-ceiling installations where space
is a constraint, the VKM can fit perfectly to deliver fresh air at a comfortable
temperature and it has an optional humidification element.

6
INTRO
Five components of indoor air quality
Ventilation
›› Ventilation: Ensures the provision of fresh air
›› Energy recovery: Delivers energy savings by transferring heat and
Energy
moisture between airflows Humidification
recovery
›› Air processing: Delivers the right supply temperature to decrease the
indoor unit load
›› Humidification: Ensures relative indoor humidity levels are respected
›› Filtration: Separates pollen, dust and pollution odours that are harmful Air
to individuals’ health Filtration
processing

Fresh air portfolio

150 500 1,000 2,000 2,500 3,000 3,500 15,000 25,000 140,000 [m3/h]

›› High efficiency counterflow heat exchanger


›› Free-cooling operation
NEW ›› EC centrifugal fan
›› Wide range of options
Decentralised systems

D-AHU MODULAR L (SMART) ›› Smart version connects Plug & Play


to Sky Air / VRV systems
›› Compact size
›› High energy efficient paper recovering sensible and latent heat
›› EC fan motors
›› Filter clogging alarm based on pressure
VAM-FC / VAM-J

›› With DX coil for temperature control


›› Increased comfort
›› Humidifier option
VKM-GB(M)
›› High efficiency aluminium plate heat exchanger
›› Pre-configured sizes
›› Plug & Play pre-configured controls
›› With DX or water coil option
D-AHU MODULAR P

›› Rotary heat exchanger (sorption and sensible technology)


Centralised systems

›› Pre-configured sizes
›› Plug & Play pre-configured controls
›› With DX or water coil option
D-AHU MODULAR R

›› Fully customizable
›› Plug & play
›› 4 types of control
›› With DX or water coil option
D-AHU Professional

7
Direct integration into the Sky
Air or VRV control solution
› Saves up to 40% in running costs
› Unified control point for the complete air
conditioning and ventilation installation

Wide range of decentralised


ERV/HRV units to suit the
building needs

8
Energy /
Heat Reclaim Ventilation

ERV/HRV BENEFITS
Ventilation Interlocked with
air conditioning system

Premium efficiency heat recovery unit


Modular L (Smart) (ALB-(RBS/LBS)) 17
NEW
›› Heat recovery unit
›› Counter flow plate heat exchanger
›› ESP up to 600 Pa
›› Operates as stand-alone or combined with Sky Air
or VRV systems

Heat reclaim ventilation (VAM-FC/J) 22

›› Heat and moisture recovery


›› Achieve free cooling with fresh outdoor air
›› Operates as stand-alone or combined with Sky Air
or VRV systems

Heat reclaim ventilation with humidification


and air processing (VKM-GB(M)) 22

›› Heat and moisture recovery


›› Humidification and air processing (preconditioning)
of fresh air
›› Achieve free cooling with fresh outdoor air
›› Plug & Play piping and wiring connection with
Daikin VRV unit(s)

9
Benefits of
Daikin ERV/HRV systems

10
1 Market leading controls & connectivity

Interlock of the ventilation operation with the air conditioner operation

ERV/HRV BENEFITS
Interlock of the ventilation operation with functions. By incorporating a variety of centralised
the air conditioner operation greatly simplifies control equipments, the user can build a large,
overall system control. The same remote controller high grade centralised control system.
centralises air conditioning and ventilation

VRV or Sky Air indoor unit

INTERLOCKING

User-friendly wired remote contoller with premium design

White Silver Black

BRC1H519W/S/K
›› Sleek and elegant design
›› Intuitive touch button control
›› 3 color versions
›› Advanced settings and monitoring can
be easily done via your smartphone Advanced user settings Field settings
›› Flat back for easy wall installation
›› Compact to fit standard size socket boxes

One
Plug & Play - integrated ventilation Stop
Shop

›› One-stop shop for all system components,


which results in streamlined design and
business solutions.
›› Efficient project follow-up, installation and
subsequent commissioning and maintenance.
›› Ventilation easily interlocked to air conditioner
operation thanks to simplified system control.
22 + + + +

11
2 Easy and flexible installation

High Static Pressure


External static pressure (ESP) up to 600 Pa (ALB)
facilitates the use with flexible ducts of varying
lengths.

Automatic Airflow External static pr essure (Pa)


Adjustment function
Automatically selects the most appropriate fan curve to achieve the Fan characteristic
units’ nominal air flow within ±10% curves

Why?

After installation the real ducting will frequently differ from the ini-
tially calculated air flow resistance  the real air flow may be much
lower or higher than designed.

Automatic Airflow Adjustment function will adapt the unit’s fan Duct resistance
matic adjustment )
curves
speed to any ducting automatically (45 fan curves are a­ vailable on
every model (ALB/VAM)), making installation much faster.

± /min)

Wide operation range ALB VAM VKM


50°
The ERV/HRV unit can be installed practically 45°CDB 46°CDB 40°CDB
anywhere.
40°
The standard operation range (outdoor temperature)
is from -15°C to 40°CDB for VKM units, from -10ºC
(+5ºC in case of upside-down installation) to 46ºCDB 30°
for VAM units, and can be extended down if a Daikin
preheater is installed. 20°
1
Contact your local dealer for more information and restrictions
10°

0° -5°
with optional

CDB -10°
preheater

-10° CDB
preheater

preheater

-15°
optional

optional
with

with

CDB
-20°
… … …

Optional pre-heater Optional pre-heater


for VAM for Modular L Smart

12
Flexible installation
280mm
Slim Design

At just 280 mm high, the slim design of ALB02*

ERV/HRV BENEFITS
the HRV unit enables it to be mounted in narrow
ceiling cavities and irregularly shaped spaces

ERV/HRV model: AHU


ON Standard air
Flexible handling unit:
ERV/HRV

Compared to a standard air handling unit, ON


CENTRAL CONTROL
the HRV models provide much greater flexibility
INDIVIDUAL
to match the actual building use, in case of a multi- ERV/HRV
CONTROL
tenant installation. Additionally, the renovation of a OFF
building can be carried out in phases.
GREATER ERV/HRV

FLEXIBILITY ON

“Super Wiring” System


A Super Wiring system is used to enable the shared system with a centralised remote control, simply by
use of wiring between indoor units, outdoor units connecting it to the outdoor units. Thanks to a non
and the centralised remote control. This system polarity wiring system, incorrect connections become
makes it easy for the user to retrofit the existing impossible and installation time is reduced.

Indoor
unit

ALB-RBS/LBS VAM/VKM
Wired remote control Outdoor unit

Connection to field-supplied booster fan increases flexibility even more


›› Longer ducting or use of central duct possible ›› Lower cost by using the booster fan instead of
›› Overcomes actual field situation when ducting is replacing with a larger unit when the ESP is not
different from calculation matched

Example when HRV ESP is not high enough or field situation differs from calculation

No booster fan with booster fan

HRV HRV
Comfort Comfort Discomfort Comfort Comfort Comfort

13
3 High efficiency

Energy saving ventilation via heat recovery


of both heat and humidity

Daikin’s ERV/HRV solutions prevent energy being


wasted by recovering up to 92% waste heat from
Recovers up to the outgoing air instead of simply expelling the heat,

92%
offering high energy efficiency.

of wasted heat
ALB-RBS/LBS

Reduce the load on the air conditioning system by up to 40%


›› 24% by using heat recovery ventilation (in comparison with normal ventilation fans)
›› 6% by switching over to auto-ventilation mode
›› 2% by using the pre-cool, pre-heat control (reduces air conditioning load
by running the HRV unit after the air conditioning is switched on)
›› 5% by enabling the free cooling operation overnight
›› 3% by preventing over-ventilation with the optional CO2 sensor

Different operation modes of ERV/HRV units

Heat exchange mode Bypass mode


Heat exchanger element
Exhaust fan Damper (heat recovery)

EA RA EA RA

Automatic
changeover
OA SA OA SA

Air supply fan

EA: Exhaust air  RA: Return air (from room)  OA: Outdoor air  SA: Supply air (to room)

14
Heat reclaim ventilation

Nighttime free cooling


Nighttime free cooling operation is an energy saving free cooling reduces the cooling load when
function operating at night when the air conditioning air conditioning is switched on in the morning,
is switched off. By ventilating rooms containing office reducing the daily running costs.

ERV/HRV BENEFITS
equipment that increases room temperature,

The VAM and Modular L Smart can also perform nighttime free cooling in stand alone operation. The set temperature is a field setting at installation.

+ OFF OFF OFF +


Free
cooling
A/C Ventilation Only ventilation A/C Ventilation
40°C

Set T°
30°C Indoor temperature
Outdoor temperature

20°C

… 5 PM 9 AM …

Prevent energy losses from over-ventilation with CO2 sensor


Enough fresh air is needed to create an enjoyable installed which switches off the ventilation
environment, but ventilating constantly is leading to system when there is enough fresh air in the room,
energy waste. Therefore an optional CO2 sensor can be thus saving energy.

Example of CO2 sensor operation in a meeting room: CO2 level


Fixed ventilation rate
9 AM 12 PM 5 PM Ventilation amount

Decrease in air volume and more energy


saving compared to fixed ventilation rate

Increase in air
volume and
better comfort
When many people are in the room,
compared to fixed
more fresh air is brought in to maintain
ventilation rate
comfortable CO2 levels. When fewer
people are in the room, energy is saved by
bringing in less fresh air.

7 8 9 10 11 12 13 14 15 16 17 18 19 hour

Morning meeting Lunch time Meeting

Up to 75% less energy consumed for ventilation in Herten building


A two-year test at a ‘netZero Energy Building’ in Herten has revealed that a huge energy saving is
possible by using CO2 sensors in conjunction with the Daikin VAM systems.

15
4 Best Comfort
• High quality indoor air
• Whisper quiet

Optional medium and fine


dust filters available The optional filter
comply with ISO 16890

Optional filters up to ePM1 70% (F8, VAM) and ePM1


80% (F9, ALB) are available to meet your customer
request or the local legislation.

Can operate in over and underpressure


to prevent unpleasant odours
The user can select 2 fresh-up modes via the remote control for a more comfortable air environment.

1. Supply rich mode (overpressure): 2. Exhaust fresh-up (underpressure):

A higher air supply than air exhaust maintains proper A higher exhaust air than air supply decreases room
room pressure to prevent back-flow of toilet/kitchen pressure to prevent the leaking of odours or floating
odours or moisture inflow. bacteria into other rooms.

Portion of fresh-up Air exhaust


HRV
operation HRV Normal Hall way
Air supply
Air exhaust ventilation fan

70%
30% Sick room
Portion of
Air supply 70% 100%
exhaust
100% operation

Relative humidity (%)


30%

eg. Office eg. Hospital

Preventing that toilet odours flow to the office No bacteria can flow from the sick room to the hall way

Low operation sound level


Continuous research by Daikin into reducing
operation sound levels has resulted in sound pressure
DBA PERCEIVED LOUDNESS SOUND
levels down to 20.5dBA (VAM150).
0 Treshold of hearing -

Daikin ERV/HRV unit


20 Extremely soft Rustling leaves

40 Very soft Quiet room


60 Moderately loud Normal conversation

80 Very loud City traffic noise

100 Extremely loud Symphonic orchestra

120 Threshold of feeling pain Jet taking off

16
Modular L Smart
Premium Efficiency Heat Recovery Unit

NEW Ventilation

MODULAR L SMART
Energy
Humidification
recovery

Air
Filtration
processing

ALB-RBS/LBS

Highlights Heat exchanger

›› Connects Plug&Play into the Sky Air and VRV ›› Premium quality counter flow plate
control network heat exchanger
›› Easy installation and commissioning ›› Up to 92% of the thermal energy recovered
›› Internal pre-filter stage (up to ePM1 50% (F7) ›› High grade aluminum allowing optimum
+ ePM1 80% (F9)) making the unit reach highest corrosion protection
indoor air quality requirements.
›› Wide air flow coverage from 150m3/h
to 3,450m3/h
›› Exceeding ERP 2018 requirements
›› Best choice when compactness is needed
(only 280 mm height up to 550 m3/h)
›› 50 mm double skin panel (120 kg/m3) for a
maximum sound and thermal insulation

EC centrifugal fan

›› Maximum ESP available 600 Pa (depending on


model sizes and airflow)
›› Inverter driven with IE4 premium efficiency motor
›› High-efficient blade profiling
›› Reduced energy consumption ErP
COMPLIANT
›› Optimized SFP (Specific Fan Power) for an
efficient unit operation

17
Premium quality to meet most
sophisticated needs

Heat exchanger
› Premium quality counterflow
plate heat exchanger
› Up to 92% of the thermal energy
recovered
› High grade aluminium that allows
best corrosion protection
› Completely joint sealing
› No screws or rivets in any part

Filters
› Easy replaceable compact filters with large
surface area, which can be removed from
bottom access
› Up to ePM1 50% (F7) + ePM1 80% (F9)
filtration efficiency
› No tools are needed to change the filters
› Fresh air filters* (ePM1 50% (F7) efficiency
as standard)
› Return filters* (ePM10 75% (M5) efficiency
as standard)

*Optional additional filter and pre-filter stage coarse 55% (G4),


ePM10 75% (M5), ePM1 50% (F7), ePM1 80% (F9)

Supply/Return fan
› Fan/motor combination with very
low noise level
› Reduced energy consumption
› Inverter driven with IE4 motor efficiency
› Infinitely variable speed
› Ultra-efficient blade profiling
› Maintenance-free ball bearings
› No screws or rivets in any part

18
MODULAR L SMART
Rectangular duct flange
The standard dimensions are:

› 250x150 (Size 2)
› 400x200 (Size 3)
› 500x300 (Size 4/5)
› 700x400 (Size 6/7)

› Optional rectangular to circular transition

Bypass damper
Unit structure
› 100% automatic bypass damper with
› External pre – painted metal sheet proportional opening for antifreeze and free
› Internal Aluzinc cooling operation
› 50 mm Double skin panel thickness
› Mineral wool insulated
› Great sound absorption and low noise Fully integratable in the DIII
› Hinged or fully removable bottom doors make the
unit easy accessible for service and maintenance network (Sky Air and VRV)
› Unit is accessible from bottom panels
› Best choice when compactness is needed (only
280 mm height for up to 550 m3/h of air flow)

19
Technical details

Control logic

› Air quality analysis with the capability of monitoring and control of the actual level of CO2 through optional sensor (accessory)
› Full automatic bypass to manage free cooling
› Filter alarm in accordance with the EU Reg 1253
› DIII-net integration through Daikin building air conditioning control systems (D-BACS)
› BMS integration through dedicated interfaces (Modbus, BACnet)

Air flow range

Modular L Smart is available in 6 sizes covering a wide range of applications such as hotels, offices, schools and light commercial
buildings

Size 3000

2300 Size 7

1500 Size 6

1200 Size 5

600 Size 4

300 Size 3

Size 2

500 1500 2500 3500


1000 2000 3000
Airflow rate (m3/h)
Max airflow calculated @100Pa of
external static pressure (ESP) From 150 up to 3450 m3/h
Nominal airflow m3/h

20
MODULAR L SMART
Return Air Fresh Air Fresh Air Return Air

Supply Air Exhaust Air Exhaust Air Supply Air

Right drain connection (ALB-RBS) Left drain connection (ALB-LBS)

Technical details

D-AHU Modular L Smart ALB-RBS/LBS 02 03 04 05 06 07


Airflow m3/h 300 600 1200 1500 2300 3000
Heat exchanger thermal efficiency1 % 90 91 90 90 92 91
External static pressure Nom. Pa 100 100 100 100 100 100
Temperature after heat exchanger1 Nom. °C 19,4 19,5 19,4 19,2 19,8 19,5
Max ESP @ nom. airflow Pa 400 450 260 270 250 210
Current Nom. A 0,52 1,17 1,91 2,48 3,76 5,39
Power input Nom. kW 0,12 0,27 0,44 0,57 0,87 1,24
SFPv2 kW/m3/s 1,24 1,49 1,28 1,32 1,32 1,46
ERP compliant ErP 2018 Compliant
Electrical supply Phase ph 1 1 1 1 1 1
Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60
Voltage V 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac
Main unit dimensions Width mm 920 1100 1600 1600 2000 2000
Height mm 280 350 415 415 500 500
Length mm 1660 1800 2000 2000 2000 2000
Rectangular duct flange Width mm 250 400 500 500 700 700
Height mm 150 200 300 300 400 400
Unit Sound Power Level (Lwa) dB 48 54 57 53 60 57
Unit Sound Pressure Level3 dBA 34 39 41 37 44 41
Weight unit kg 125 180 270 280 355 360

1. Winter design condition: Outdoor: -5°C, 90% Indoor: 22°C,50%


2. SFPv is a parameter that quantifies the fan efficiency (the lower it is the better will be). This reduces if airflow decreases.
3. According to EN3744. Surrounding, Directivity (Q) = 2, @ 1,5m distance

21
ERV
energy reclaim ventilation
Heat reclaim ventilation, air processing and humidification

Ventilation Ventilation

Energy Energy
Humidification Humidification
recovery recovery

Air Air
Filtration Filtration
processing processing

VAM-FC / VAM-J VKM-GB(M)

High efficiency Maximum flexibility

›› Energy saving ventilation via enthalpy recovery of ›› Plug & Play - integrated ventilation
both heat and humidity ›› Flexible installation
›› Reduce the load on the air conditioning system by ›› Wide range of units
up to 40% ›› High static pressure
›› Nighttime free cooling ›› Wide operation range
›› Prevent energy losses from over-ventilation with ›› Connection to field-supplied booster fan
CO2 sensor increases flexibility even more (VAM-FC/J only)
›› No drain needed (VAM-FC/J only)

High indoor air quality & whisper quiet


operation

›› Optional medium and fine dust filters (VAM-FC/J


only)
›› Can operate in over and underpressure to prevent
unpleasant odours
›› Low operation sound level

22
Energy saving ventilation via enthalpy recovery
of both heat and humidity

Daikin’s ERV solutions prevent energy being wasted Specially developed heat exchange element
by recovering up to 85% waste heat from the
Recovers up to outgoing air instead of simply expelling the heat, The heat exchange element rapidly recovers heat

85%
offering high energy efficiency. contained in latent heat (vapour).

of waste heat

Outdoor Indoor
SA
Operation of the high 30.6°C 27.4°C Temperature SA
efficiency paper. 62% RH 63% RH and humidity

VAM/VKM
are exhanged
Cross flow of air to
between the
exchange heat and RA
32°C RA layers
moisture.
70% RH 26°C
50% RH
Integrally-formed liner

RH: Relative Humidity


SA: Supply Air (to room)
RA: Return Air (from room)

High indoor comfort


Thanks to the heat and moisture exchange the hot
and humid outside air is brought to levels close to
indoor conditions saving on the air conditioning
running cost and maintaining comfort.

Can be installed Horizontal installation Vertical installation

horizontally, upside down Ceiling Ceiling

or vertically
False ceiling Access
The VAM models do not require a drain, giving hatch
greater flexibility for the installation of the units.

In case of upside down or vertical installation the Switch box


minimum outside temperature is +5°C
instead of -10°C.

Access
hatch
Maintenance cover

23
Creating a high quality environment
Maintain a comfortable indoor environment without fluctuations in room temperature.

How do the ERV units work?

In heating In cooling
Heat recovery Heat recovery
+ +
Heating Cooling 100 80
+ 100 80
60

Humidifying 60
Outdoor air
temperature
Effect of full heat exchange in summer
Effect of cooling
1
40

40 2

Indoor temperature during cooling

Effect of 20
Indoor temperature during heating humidification
3 20
2
Relative humidity (%)

Outdoor air 1 Effect of


temperature in winter
heating
Effect of full heat exchange

-5 0 5 10 15 20 25 30 35 40 -5 0 5 10 15 20 25 30 35 40

Dry bulb temperature (°CDB) Dry bulb temperature (°CDB)

In heating we bring in cold outdoor fresh air and want to avoid cold draught In cooling we bring in hot outdoor fresh air and want to prevent additional load on
and dry air. the air conditioning system and too hot indoor temperatures.

1.  Cold outside air is crossed with hot inside air. 1.  Hot outside air is crossed with cold inside air.
In the example the incoming air is heated up from 0 to 16°CDB while keeping In the example the incoming air is cooled down from 34 to 27°CDB while keeping
the same relative humidity. This is the effect of the heat and moisture exchange. the same relative humidity. This is the effect of the heat and moisture exchange.

2.  The DX coil further cools down the air to prevent hot indoor temperatures and reduce
2.  The DX coil further heats up the air to prevent cold draught. In the example the
the load on the air conditioning system.
incoming air is further heated from 16 to 34°CDB. Because the air is heated up the
relative humidity decreases. In the example the incoming air is further cooled down from 27 to 20°CDB.

3.  To counter negative effects of dry air the air passes the humidifier which adds
moisture in case needed. 3.  No humidification is needed in cooling as the air is not dried out
In the example the relative humidity rises from 22 to a comfortable 42%.

The result is incoming fresh air with the same humidity and slightly higher
The result is incoming fresh air with a slightly lower temperature for perfect comfort.
temperature for perfect comfort.

24
Humidification

Operation example: humidification & air processing (heating mode)1

VAM/VKM
Heat Exchanger
Exhaust Fan Damper Motor DX coil (Direct expansion coil)
Elements
EA Damper
(Exhaust air to outdoors)

OA
(Fresh air from outdoors)

RA
(Return air from room)

Air Supply Fan SA (Supply air to room)

Electronics Box (Control box)

Float switch Solenoid


Humidifier element: valve
Utilizing the principle of capillary action, water is
permeated throughout the humidifier element.
The heated air from the DX coil passes through the water
humidifier and absorbs the moisture. SA
AIRFLOW

Drain pan Drain

1
VKM-GM example

25
VAM-FC/VAM-J

New diamond
Energy reclaim ventilation Return air
shape heat
Supply air exchanger!
Ventilation with heat recovery as standard

›› NEW Thinnest High Efficiency Enthalpy Heat Exchanger in the


market (J-series)
›› Energy saving ventilation using indoor heating, cooling and
moisture recovery
›› Free cooling possible when outdoor temperature is below indoor
Exhaust air
temperature (eg. during nighttime)
›› Prevent energy losses from over-ventilation while improving Fresh air
indoor air quality with optional CO2 sensor
›› NEW Possibility to change ESP via wired remote control allows
optimisation of the supply air volume (J - series)
›› Can be used as stand alone or integrated in the Sky Air
or VRV system
›› Wide range of units: air flow rate from 150 up to 2,000 m³/h High efficiency filters available:
›› Shorter installation time thanks to easy adjustment of nominal air ePM10 70% (M6), ePM1 55% (F7) and ePM1 70% (F8)
flow rate, so less need for dampers compared with
traditional installation
›› No drain piping needed
›› Can operate in over- and under pressure
›› Total solution for fresh air with Daikin supply of both VAM / VKM
and electrical heaters ErP
COMPLIANT

Ventilation VAM/VAM 150FC 250FC 350J 500J 650J 800J 1000J 1500J 2000J
Power input - 50Hz Heat Nom. Ultra high/High/Low kW 0.132/0.111/ 0.161/0.079/ 0.097 /0.070 / 0.164 /0.113 / 0.247 /0.173 / 0.303 /0.212 / 0.416 /0.307 / 0.548 /0.384 / 0.833 /0.614 /
exchange
mode 0.058 0.064 0.039 0.054 0.081 0.103 0.137 0.191 0.273
Bypass mode Nom. Ultra high/High/Low kW 0.132/0.111/ 0.161/0.079/ 0.085 /0.061 / 0.148 /0.100 / 0.195 /0.131 / 0.289 /0.194 / 0.417 /0.300 / 0.525 /0.350 / 0.835 /0.600 /
0.058 0.064 0.031 0.045 0.059 0.086 0.119 0.156 0.239
Temperature Ultra high/High/Low % 77.0 (1) / 72.0 (2)/ 74.9 (1) / 69.5 (2)/
85.1 /86.7 / 80.0 /82.5 / 84.3 /86.4 / 82.5 /84.2 / 79.6 /81.8 / 83.2 /84.8 / 79.6 /81.8 /
exchange 78.3 (1) / 72.3 (2)/ 76.0 (1) / 70.0 (2)/
90.1 87.6 90.5 87.7 86.1 88.1 86.1
efficiency - 50Hz 82.8 (1) / 73.2 (2) 80.1 (1) / 72.0 (2)
Enthalpy exchange Cooling Ultra high/High/Low % 60.3 (1)/61.9 (1)/ 60.3 (1)/61.2 (1)/ 65.2 /67.9/ 59.2 /61.8 / 59.2 /63.8 / 67.7 /70.7 / 62.6 /66.4 / 68.9 /71.8 / 62.6 /66.4 /
efficiency - 50Hz 67.3 (1) 64.5 (1) 74.6 69.5 73.1 76.8 74.0 77.5 74.0
Heating Ultra high/High/Low % 66.6 (1)/67.9 (1)/ 66.6 (1)/67.4 (1)/ 75.5 /77.6 / 69.0 /72.2 / 73.1 /76.3 / 72.8 /75.3 / 68.6 /71.7 / 73.8 /76.1 / 68.6 /71.7 /
72.4 (1) 70.7 (1) 82.0 78.7 82.7 80.2 77.9 80.8 77.9
Operation mode Heat exchange mode, bypass mode, fresh-up mode
Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange
Heat exchange element Specially processed non-flammable paper
Dimensions Unit HeightxWidthxDepth mm 285x776x525 301x1,113x886 368x1,354x920 368x1,354x1,172 731x1,354x1,172
Weight Unit kg 24.0 46.5 61.5 79.0 157
Casing Material Galvanised steel plate
Fan Air flow Heat Ultra high/High/ m³/h 350 (1)/ 500 (1)/ 650 (1)/ 800 (1)/ 1,000 (1)/ 1,500 (1)/ 2,000 (1)/
exchange Low 150 /140 /105 250 /230 /155 300 (1)/ 425 (1)/ 550 (1)/ 680 (1)/ 850 (1)/ 1,275 (1)/ 1,700 (1)/
rate - mode 200 (1) 275 (1) 350 (1) 440 (1) 550 (1) 825 (1) 1,100 (1)
50Hz Bypass mode Ultra high/High/ m³/h 350 (1)/ 500 (1)/ 650 (1)/ 800 (1)/ 1,000 (1)/ 1,500 (1)/ 2,000 (1)/
Low 150 /140 /105 250 /230 /155 300 (1)/ 425 (1)/ 550 (1)/ 680 (1)/ 850 (1)/ 1,275 (1)/ 1,700 (1)/
200 (1) 275 (1) 350 (1) 440 (1) 550 (1) 825 (1) 1,100 (1)
External static Ultra high/High/Low Pa 90 /87/40 70 /63/25 90 (1)/70.0 /50.0 (1)
pressure - 50Hz
Air filter Type Multidirectional fibrous fleeces Multidirectional fibrous fleeces (G3)
Sound pressure Heat Ultra high/High/Low dBA 27.0 /26.0 28.0 /26.0 34.5 (1)/ 37.5 (1)/ 39.0 (1)/ 39.0 (1)/ 42.0 (1)/ 42.0 (1)/ 45.0 (1)/
exchange 32.0 (1)/ 35.0 (1)/ 36.0 (1)/ 36.0 (1)/ 38.5 (1)/ 39.0 (1)/ 41.5 (1)/
level - 50Hz mode /20.5 /21.0 29.0 (1) 30.5 (1) 31.0 (1) 30.5 (1) 32.5 (1) 33.5 (1) 36.0 (1)
Bypass Ultra high/High/Low dBA 27.0 /26.5 28.0 /27.0 34.5 (1)/ 38.0 (1)/ 38.0 (1)/ 40.0 (1)/ 42.5 (1)/ 42.0 (1)/ 45.0 (1)/
/20.5 /21.0 32.0 (1)/ 35.0 (1)/ 34.5 (1)/ 36.5 (1)/ 40.0 (1)/ 39.0 (1)/ 41.0 (1)/
mode 28.0 (1) 29.5 (1) 30.5 (1) 30.5 (1) 32.5 (1) 32.5 (1) 35.0 (1)
Operation range Around unit °CDB - 0°C~40°CDB, 80% RH or less
Connection duct diameter mm 100 150 200 250 2x250
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Current Maximum fuse amps (MFA) A 15.0 16.0
Specific energy Cold climate kWh/(m².a) -56.0 (5) -60.5 (5) -
consumption (SEC) Average climate kWh/(m².a) -22.1 (5) -27.0 (5) -
Warm climate kWh/(m².a) -0.100 (5) -5.30 (5) -
SEC class D / See note 5 B / See note 5 -
Maximum flow rate Flow rate m³/h 130 207 -
at 100 Pa ESP Electric power input W 129 160 -
Sound power level (Lwa) dB 40 43 51 54 58 61 62 65
Annual electricity consumption kWh/a 18.9 (5) 13.6 (5) -
Annual heating Cold climate kWh/a 41.0 (5) 40.6 (5) -
saved Average climate kWh/a 80.2 (5) 79.4 (5) -
Warm climate kWh/a 18.5 (5) 18.4 (5) -
(1)Measured according to JIS B 8628 | (2)Measured at reference flow rate according to EN13141-7 | Measured according to EN308 : 1997 | In accordance with commission regulation (EU) No 1254/2014 | In accordance with commission regulation (EU) No
1253/2014 | At reference flow rate in accordance with commission regulation (EU) No 1254/2014 | Clean the filter when the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit's energy efficiency.

26
VKM-GB/VKM-GBM

Energy reclaim ventilation,


humidification
and air processing
Pre heating or cooling of fresh air for lower load on the air
conditioning system

›› Energy saving ventilation using indoor heating, cooling and


moisture recovery
›› Creates a high quality indoor environment by pre conditioning
incoming fresh air
›› Humidification of the incoming air results in comfortable indoor
humidity level, even during heating
›› Free cooling possible when outdoor temperature is below indoor
temperature (eg. during nighttime) VKM80-100GB(M)
›› Low energy consumption thanks to DC fan motor
›› Prevent energy losses from over-ventilation while improving
indoor air quality with optional CO2 sensor
›› Shorter installation time thanks to easy adjustment of nominal air
flow rate, so less need for dampers compared with
traditional installation
›› Specially developed heat exchange element with High Efficiency
Paper (HEP)
›› Can operate in over- and under pressure

VAM/VKM
Ventilation VKM-GB/VKM-GBM 50GB 80GB 100GB 50GBM 80GBM 100GBM
Power input - 50Hz Heat exchange Nom. Ultra high/ kW 0.270/0.230/ 0.330/0.280/ 0.410/0.365/ 0.270/0.230/ 0.330/0.280/ 0.410/0.365/
mode High/Low 0.170 0.192 0.230 0.170 0.192 0.230
Bypass mode Nom. Ultra high/ kW 0.270/0.230/ 0.330/0.280/ 0.410/0.365/ 0.270/0.230/ 0.330/0.280/ 0.410/0.365/
High/Low 0.140 0.192 0.230 0.170 0.192 0.230
Fresh air Cooling kW 4.71 / 1.91 / 3.5 7.46 / 2.96 / 5.6 9.12 / 3.52 / 7.0 4.71 / 1.91 / 3.5 7.46 / 2.96 / 5.6 9.12 / 3.52 / 7.0
conditioning load Heating kW 5.58 / 2.38 / 3.5 8.79 / 3.79 / 5.6 10.69 / 4.39 / 7.0 5.58 / 2.38 / 3.5 8.79 / 3.79 / 5.6 10.69 / 4.39 / 7.0
Temperature Ultra high/High/Low %
exchange efficiency 76/76/77.5 78/78/79 74/74/76.5 76/76/77.5 78/78/79 74/74/76.5
- 50Hz
Enthalpy exchange Cooling Ultra high/High/Low % 64/64/67 66/66/68 62/62/66 64/64/67 66/66/68 62/62/66
efficiency - 50Hz Heating Ultra high/High/Low % 67/67/69 71/71/73 65/65/69 67/67/69 71/71/73 65/65/69
Operation mode Heat exchange mode / Bypass mode / Fresh-up mode
Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange
Heat exchange element Specially processed non-flammable paper
Humidifier System - Natural evaporating type
Dimensions Unit HeightxWidthxDepth mm 387x1,764x832 387x1,764x1,214 387x1,764x832 387x1,764x1,214
Weight Unit kg 94 110 112 100 119 123
Casing Material Galvanised steel plate
Fan-Air flow rate Heat exchange mode Ultra high/High/Low m³/h 500/500/440 750/750/640 950/950/820 500/500/440 750/750/640 950/950/820
- 50Hz Bypass mode Ultra high/High/Low m³/h 500/500/440 750/750/640 950/950/820 500/500/440 750/750/640 950/950/820
Fan-External static Ultra high/High/Low Pa
210/170/140 210/160/110 150/100/70 200/150/120 205/155/105 110/70/60
pressure - 50Hz
Air filter Type Multidirectional fibrous fleeces
Sound pressure Heat exchange mode Ultra high/High/Low dBA 39/37/35 41.5/39/37 41/39/36.5 38/36/34 40/37.5/35.5 40/38/35.5
level - 50Hz Bypass mode Ultra high/High/Low dBA 40/38/35.5 41.5/39/37 41/39/36.5 39/36/34.5 41/38/36 41/39/35.5
Operation range Around unit °CDB 0°C~40°CDB, 80% RH or less
Supply air °CDB -15°C~40°CDB, 80% RH or less
Return air °CDB 0°C~40°CDB, 80% RH or less
On coil temperature Cooling/Max./Heating/Min. °CDB -15/43 -15/43
Refrigerant Control Electronic expansion valve
Type R-410A
GWP 2,087.5
Connection duct diameter mm 200 250 200 250
Piping connections Liquid OD mm 6.35
Gas OD mm 12.7
Water supply mm - 6.4
Drain PT3/4 external thread
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Current Maximum fuse amps (MFA) A 15

27
For small to large commercial spaces Daikin offers
a range of inverter condensing units for use in
conjunction with air handling units. In situations
where Daikin commercial range ventilation units
cannot satisfy the ventilation requirement due to
building constraints (large atriums, banquet halls
etc), air handling units represent the ideal solution.
Air handling units provide large fresh air volumes
(>500 m3/h) and high ESPs enabling the use of
extensive ductwork runs.

An air handler or air handling unit provides


a tailor-made solution for optimising air conditions
throughout multiple spaces. An air handling can be
customised to your building - with no installation
restrictions or design limitations - as air handling
units are based on a completely unique modular
design, so they can be sized (in increments of 1 cm)
to your exact requirements.

28
Daikin

air handling units


Ventilation

Energy
Humidification
recovery

Air
Filtration
processing

AHU

AIR HANDLING UNITS


Air handling unit applications

Why choose Daikin air handling units with a DX connection? 30

Why use VRV and ERQ condensing units for connection


to air handling units? 32

In order to maximise installation flexibility,


4 types of control systems are offered 33

VRV - for larger capacities (from 8 to 54HP) 34

ERQ - for smaller capacities (from 100 to 250 class) 35

Integration of VRV and ERQ in third party air handling units 36

Pair and multi application selection 37

29
Daikin
air handling units solutions
You will find your match

Why choose Daikin air handling units with a DX connection?

Simplifying business Complete range of possibilities

The unique total solution approach by Daikin helps Thanks to the most complete offer in the market,
businesses to propose better cross-pillar solutions, to Daikin has the solution for all types of commercial
increase their success ratio by providing unmatchable applications requiring fresh air. Daikin provides
product combinations to the end-user and to ventilation solutions based on AHU from 2,500 m3/h
simplify the life of installers by supplying high-quality up to 140,000 m3/h either with natural heat recovery
products coming from the same manufacturer. or more advanced ventilation solutions where a
Contrary to other manufacturers, Daikin does not VRV outdoor unit can be connected to the Daikin
use OEM products in its AHU with DX offer. Many AHU for ultimate climate control. The harmonized
competitors are either offering OEM DX outdoor units control between the VRV outdoor unit and the AHU
or OEM AHU which create additional problems when offer outstanding 24h/7 control of the system when
warranties or faults arise. Having a single interface connected to an iTM.
for your business makes Daikin the right choice.

One stop shop

Daikin is the only global manufacturer in the market


capable of offering a true Plug & Play solution
where Daikin AHUs manufactured by Daikin Applied
Europe and certified by Eurovent, offer off-the-shelf
compatibility with Daikin’s unique VRV outdoor unit
Advantages
range for the best performance in the market. ›› Unique manufacturer offering a complete
This unique integration of cross-pillar products under range
the same umbrella, gives the costumer both peace-of- ›› Plug & Play solution
mind and added value when promoting a total solution ›› Direct iTM compatibility
approach.

30
Daikin's

fresh air solution

High efficient EC fan Factory fitted and tested DX heat exchanger

AIR HANDLING UNITS

Efficient filtration Heat wheel for heat recovery

31
Daikin Fresh air package - overview

Why use VRV and ERQ condensing units for connection


to air handling units?
High Efficiency

Daikin heat pumps are renowned for their high while the outdoor air is too cold to be brought
energy efficiency. Integrating the AHU with a heat inside in an unconditioned state. In this case heat
recovery system is even more effective since from the offices is merely transferred to heat up
an office system can frequently be in cooling mode the cold incoming fresh air.

Outside air = 10°C

Fresh air supplied at 21°C.


The temperature difference with
the outdoor air is heated up for free
by heat recovery via A/C system

Indoor temperature 22°C,


needs cooling because of solar
radiation.
The excessive heat can be
transferred to the AHU.

Fast response to changing loads


resulting in high comfort levels Easy Design and Installation

Daikin ERQ and VRV units respond rapidly The system is easy to design and install since
to fluctuations in supply air temperature, resulting no additional water systems such as boilers,
in a steady indoor temperature and resultant high tanks and gas connections etc. are required.
comfort levels for the end user. The ultimate is This also reduces both the total system investment
the VRV range which improves comfort even more and running cost.
by offering continuous heating, also during defrost.

Daikin Fresh air package

›› Plug & Play connection between VRV/ERQ and the entire D-AHU modular range.
›› Factory fitted and welded control and expansion valve kits.

VRV IV or ERQ
condensing unit

Factory fitted and welded


fresh air package

Electronic expansion
valve Control box
(EKEXV) (EKEQ)

32
Daikin Fresh air package - Controls

In order to maximise installation flexibility,


4 types of control systems are offered

W control: Off the shelf control of air temperature (discharge Z control: Control of air temperature (suction temperature, room
temperature, suction temperature, room temperature) via any temperature) via Daikin control (no DDC controller needed)
DDC controller, easy to setup Y control: Control of refrigerant (Te/Tc) temperature via Daikin
X control: Precise control of air temperature (discharge temperature, control (no DDC controller needed)
suction temperature, room temperature) requiring
a preprogrammed DDC controller (for special applications)

1. W control (TS/TR/TROOM control): 2. X control (TS/TR/TROOM control):

Air temperature control via DDC controller Precise air temperature control via DDC controller
Room temperature is controlled as a function of the air handling Room temperature is controlled as a function of the air handling
unit suction or discharge air (customer selection). The DDC unit suction or discharge air (customer selection). The DDC
controller is translating the temperature difference between set controller is translating the temperature difference between set
point and air suction temperature (or air discharge temperature point and air suction temperature (or air discharge temperature
or room temperature) into a proportional 0-10V signal which is or room temperature) into a reference voltage (0-10V) which is
transferred to the Daikin control box (EKEQFCBA). This voltage transferred to the Daikin control box (EKEQFCBA). This reference
modulates the capacity requirements of the outdoor unit. voltage will be used as the main input value for the compressor
frequency control.
OR
OR OR
OR
AHU
AHU AHU
AHU

TEXT
EXT
TTR TEXT
EXT
TTR
R R
0-10V Control
Daikin boxbox:
control 0-10V Control
Daikin boxbox:
control
DDC
DDC + DDC
DDC +
EKEQFCBA
EKEQFCBA TE TC EKEQFCBA
EKEQFCBA
TTOA TS TTOA TETC TS
OA OA
S S
- -

TROOM TROOM
ROOM ROOM

AIR HANDLING UNITS


4. Z control (TS/TROOM control):
3. Y control (TE/TC control):
Control your AHU just like a VRV indoor unit with 100% fresh air
By fixed evaporating /condensing temperature Allows the possibility to control the AHU just like a VRV indoor
A fixed target evaporating or condensing temperature can be set unit. Meaning temperature control will be focused on return air
by the customer. In this case, room temperature is only indirectly temperature from the room into the AHU. Requires BRC1* for
controlled. A Daikin wired remote control (BRC1* - optional) have to operation. The only control that allows the combination of other
be connected for initial set-up but not required for operation. indoor units to the AHU at the same time.

AHU
TTEXT
EXT
TTRR
BRC1D*
BRC1D* Control box
BRC1E* TEXT
EXT TRR
BRC1E* EKEQFCBA + BRC1D* Control box
Control box
BRC1H* TTOA TE TC TTS
BRC1D*
BRC1E* EKEQMCBA (VRVIV)
EKEQMCBA (VRV IV) +
OA S BRC1E*
- BRC1H* EKEQDCB (ERQ)
(ERQ) TTOA TE
OA TC TS
-

TTROOM
ROOM
OR
OR
TTROOM
ROOM

TS = Supply air temperature TR = Return air temperature TOA = Outdoor air temperature TROOM = Room air temperature
TEXT = Extraction air temperature TE = Evaporating temperature TC = Condensing temperature

Option kit Features


Possibility W Off-the-shelf DDC controller that requires no pre-configuration
Possibility X EKEQFCBA Pre-configured DDC controller required
Possibility Y Using fixed evaporating temperature, no set point can be set using remote control
EKEQDCB Using Daikin infrared remote control BRC1*
Possibility Z
EKFQMCBA* Temperature control using air suction temperature or room temperature (via remote sensor)
* EKEQMCB (for ’multi’ application)

33
Daikin Fresh air package - VRV connections

- for larger capacities (from 8 to 54HP)


An advanced solution for both pair and multi application

›› Inverter controlled units


›› Heat recovery, heat pump
›› R-410A
›› Control of room temperature via Daikin control
›› Large range of expansion valve kits available
›› BRC1H519W/S/K is used to set the set point temperature
(connected to the EKEQMCBA).
›› Connectable to all VRV heat recovery and
heat pump systems

W, X, Y control for VRV IV heat pump Z control for all VRV outdoor units

Refrigerant piping
F1-F2
P1-P2

34
Daikin Fresh air package - ERQ connections

ERQ - for smaller capacities


(from 100 to 250 class)

A basic fresh air solution for pair application

›› Inverter controlled units


›› Heat pump
›› R-410A
›› Wide range of expansion valve kits available
›› Perfect for the Daikin Modular air handling unit
ERQ-AW1
The “Daikin Fresh Air Package” provides a complete Plug & Play Solution including
AHU, ERQ or VRV Condensing Unit and all unit control (EKEQ, EKEX, DDC controller)
factory mounted and configured. The easiest solution with only one point of contact.

Ventilation ERQ 100AV1 125AV1 140AV1


Capacity range HP 4 5 6
Cooling capacity Nom. kW 11.2 14.0 15.5
Heating capacity Nom. kW 12.5 16.0 18.0
Power input Cooling Nom. kW 2.81 3.51 4.53
Heating Nom. kW 2.74 3.86 4.57
EER 3.99 3.42
COP 4.56 4.15 3.94
Dimensions Unit HeightxWidthxDepth mm 1,345x900x320
Weight Unit kg 120
Casing Material Painted galvanized steel plate
Fan-Air flow rate Cooling Nom. m³/min 106
Heating Nom. m³/min 102 105
Sound power level Cooling Nom. dBA 66 67 69
Sound pressure Cooling Nom. dBA 50 51 53
level Heating Nom. dBA 52 53 55

AIR HANDLING UNITS


Operation range Cooling Min./Max. °CDB -5/46
Heating Min./Max. °CWB -20/15.5
On coil temperature Heating/Min./Cooling/Max. °CDB 10/35
Refrigerant Type R-410A
Charge kg 4.0
TCO₂eq 8.4
GWP 2,087.5
Control Expansion valve (electronic type)
Piping connections Liquid OD mm 9.52
Gas OD mm 15.9 19.1
Drain OD mm 26x3
Power supply Phase/Frequency/Voltage Hz/V 1N~/50/220-240
Current Maximum fuse amps (MFA) A 32.0
Ventilation ERQ 125AW1 200AW1 250AW1
Capacity range HP 5 8 10
Cooling capacity Nom. kW 14.0 22.4 28.0
Heating capacity Nom. kW 16.0 25.0 31.5
Power input Cooling Nom. kW 3.52 5.22 7.42
Heating Nom. kW 4.00 5.56 7.70
EER 3.98 4.29 3.77
COP 4.00 4.50 4.09
Dimensions Unit HeightxWidthxDepth mm 1,680x635x765 1,680x930x765
Weight Unit kg 159 187 240
Casing Material Painted galvanized steel plate
Fan-Air flow rate Cooling Nom. m³/min 95 171 185
Heating Nom. m³/min 95 171 185
Sound power level Nom. dBA 72 78
Sound pressure level Nom. dBA 54 57 58
Operation range Cooling Min./Max. °CDB -5/43
Heating Min./Max. °CWB -20/15
On coil temperature Heating/Min./Cooling/Max. °CDB 10/35
Refrigerant Type R-410A
Charge kg 6.2 7.7 8.4
TCO₂eq 12.9 16.1 17.5
GWP 2,087.5
Control Electronic expansion valve
Piping connections Liquid OD mm 9.52
Gas OD mm 15.9 19.1 22.2
Power supply Phase/Frequency/Voltage Hz/V 3N~/50/400
Current Maximum fuse amps (MFA) A 16 25

35
Integration with third party air handling units

Integration of ERQ and VRV in third party air handling units


a wide range of expansion valve kits and control boxes

Combination table
Control box Expansion valve kit
Mixed connection with
EKEQDCB EKEQFCBA EKEQMCBA EKEXV50 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 EKEXV400 EKEXV500
VRV indoor units
Z control W,X,Y control Z control - - - - - - - - - -
ERQ100 P P - - P P P P - - - - -
1-phase ERQ125 P P - - P P P P P - - - -
ERQ140 P P - - - P P P P - - - -
Not possible
ERQ125 P P - - P P P P P - - - -
3-phase ERQ200 P P - - - - P P P P P - -
ERQ250 P P - - - - - P P P P - -
VRV III - - n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 Mandatory
VRV IV H/P / Possible (not
VRV IV W-series - P (1 -> 3) n2 n2 n2 n2 n2 n2 n2 n2 n2 n2 n2 mandatory)
VRV IV S-series
VRV IV H/R - n1 - n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 Mandatory
VRV IV i-series
• P (pair application): combination depends on the capacity of the air handling unit
• n1 (multi application) - Combination of AHUs and VRV DX indoors (mandatory). To determine the exact quantity please refer to the engineering data book.
• n2 (multi application) - Combination of AHUs and VRV DX indoors (not mandatory). To determine the exact quantity please refer to the engineering data book.
• Control box EKEQFA can be connected to some types of VRV IV outdoor units (with a maximum of 3 boxes per unit). Do not combine EKEQFA control boxes with VRV DX indoor units, RA indoor units or hydroboxes

Capacity table

Cooling Heating
Allowed heat exchanger Allowed heat exchanger Allowed heat exchanger Allowed heat exchanger
EKEXV Class capacity (kW) volume (dm3) EKEXV Class capacity (kW) volume (dm3)
Minimum Standard Maximum Minimum Maximum Minimum Standard Maximum Minimum Maximum
50 5.0 5.6 6.2 1.33 1.65 50 5.6 6.3 7.0 1.33 1.65
63 6.3 7.1 7.8 1.66 2.08 63 7.1 8.0 8.8 1.66 2.08
80 7.9 9.0 9.9 2.09 2.64 80 8.9 10.0 11.1 2.09 2.64
100 10.0 11.2 12.3 2.65 3.30 100 11.2 12.5 13.8 2.65 3.30
125 12.4 14.0 15.4 3.31 4.12 125 13.9 16.0 17.3 3.31 4.12
140 15.5 16.0 17.6 4.13 4.62 140 17.4 18.0 19.8 4.13 4.62
200 17.7 22.4 24.6 4.63 6.60 200 19.9 25.0 27.7 4.63 6.60
250 24.7 28.0 30.8 6.61 8.25 250 27.8 31.5 34.7 6.61 8.25
400 35.4 45.0 49.5 9.26 13.2 400 39.8 50.0 55.0 9.26 13.2
500 49.6 56.0 61.6 13.2 16.5 500 55.1 63.0 69.3 13.2 16.5
Saturated evaporating temperature: 6°C Saturated condensing temperature: 46°C
Air temperature: 27°C DB / 19°C WB Air temperature: 20°C DB

EKEXV - Expansion valve kit for air handling applications

Ventilation EKEXV 50 63 80 100 125 140 200 250 400 500


Dimensions Unit mm 401x215x78
Weight Unit kg 2.9
Sound pressure level Nom. dBA 45
Operation range On coil Heating Min. °CDB 10 (1)
temperature Cooling Max. °CDB 35 (2)
Refrigerant Type / GWP R-410A / 2.087,5
Piping connections Liquid OD mm 6.35 9.52 12.7 15.9

(1) The temperature of the air entering the coil in heating mode can be reduced to -5°CDB. Contact your local dealer for more information. (2) 45% Relative humidity.

EKEQ - Control box for air handling applications

Ventilation EKEQ FCBA DCB MCBA


Application See note Pair Multi
Outdoor unit ERQ / VRV ERQ VRV
Dimensions Unit mm 132x400x200
Weight Unit kg 3.9 3.6
Power supply Phase/Frequency/Voltage Hz/V 1~/50/230

The combination of EKEQFCBA and ERQ is in pair application. The EKEQFCBA can be connected to some type of VRV IV outdoor units with a maximum of 3 control boxes. The combination with DX indoor units,
hydroboxes, RA outdoor units, ... is not allowed. Refer to the combination table drawing of the outdoor unit for details.

36
Selection

Pair application selection


›› the outdoor unit is connected to ONE COIL (with single circuit
or maximum 3 interlaced circuits) using up to 3 control boxes
›› indoor unit combination is not allowed
›› only works with X, W, Y control

Step 1: Required AHU capacity Step 3: Control box selection

An AHU with double flow, heat recovery and 100% fresh air is to In this particular case, the control will work with precise air
be installed in Europe where the outdoor sizing temperature is 35 temperature control. Only W or X control allow this. Since the
ºCDB and the target supply air temperature for fresh air is 25 ºCDB. consultant wants to use an “off-the-shelf” DDC module, the
Load calculations point to a required capacity of 45kW. EKEQFCBA box with W control allows easy set-up due to pre-set
By checking on the EKEXV capacity table, for cooling operation, factory values.
40kW falls within the 400 class valve. Since 40kW is not the nominal
capacity, a class adjustment has to be done. 40/45=0,89 and
0,89x400=356. So the capacity class of the expansion valve kit is
356.

Step 2: Outdoor unit selection

For this AHU, a VRV IV heat pump model with continuous heating is
going to be used (RYYQ-T series). For a capacity of 40kW at 35 ºCDB,
an outdoor of 14HP (RYYQ14T) is selected. The capacity class of the
14 HP outdoor unit is 350.

Total connection ratio of the system is 356/350=102% hence it falls


within the range 90-110%.

AIR HANDLING UNITS


Multi application selection
›› the outdoor unit can be connected to MULTIPLE COILS
(and their control boxes)
›› indoor units are also connectable but not mandatory
›› only works with Z control

Step 1: Required AHU capacity Step 2: Outdoor unit selection

An AHU with double flow, heat recovery and 100% fresh air is to
be installed in Europe where the outdoor sizing temperature is For this system where a AHU is connected with indoor units, it is
35 ºCDB and the target supply air temperature for fresh air is 25 mandatory to use a heat recovery unit. By consulting the engi-
ºCDB. On top of this, for this building, 5 round-flow cassette units neering databook for REYQ-T, the total required capacity of 42,5
FXFQ50A will also be connected to this OU. kW requires a 16HP model REYQ16T. Which will deliver 45kW at the
Load calculations point to a required capacity of 20kW for the AHU design temperature of 35 ºCDB. This unit has a capacity class of 400.
and 22,5 kW for the indoor untis. Total connection ratio of the system is 428/400=107% hence it falls
By checking on the EKEXV capacity table, for cooling operation, within the range 50-110%.
20kW falls within the 200 class valve. Since 22,4 kW is the nominal
capacity, a class adjustment has to be done. 20/22,4=0,89 and Step 3: Control box selection
0,89x200=178. So the capacity class of the expansion valve kit is
178. Total capacity class of the indoor unit system is 178+250=428 In this particular case, the only available control is Z control and the
combination of AHU and VRV DX indoor units requires EKEQMCBA
control box.

37
Air handling application

Pair application examples


Pair application layout #1: Example for W or X control with EKEQFCBA box

F1/F2

EKEQFCBA EKEKXV*
Digital signal
to steer EEV Treturn

Only for
commissioning OR

Tsupply

0-10 V signal Temperature sensor reading


From DDC to EKEQFCBA input to DDC

Outdoor unit compatibility More than 3 control boxes


RYYQ8T > RYYQ54T connected to same outdoor
DX coil

RXYQ8T > RXYQ54T


RWEYQ8T9 > RWEYQ30T9
ERQ100 > ERQ250 1
(1) Only available in 1 to 1 combination
Two control boxes connected
to Outdoor 1 to circuits 1
Connection restrictions and 2 of coil A. Control box 3
DX coil

Connection Ratio VRV: between 90-110% connected to outdoor 2 and


circuit 3 of coil A.
Connection Ratio ERQ: between 50-110%
CR= Σ IU CC = Σ (CF x EKEXV CC)1-3
Σ OU CC Σ OU CC

CF is the correction factor


CC is the capacity class Two control boxes on coil A
DX coil

(2 circuits) and another control


box on coil B (1 circuit).
Both connected to same
DX coil

outdoor

38
Air handling application

Pair application layout #2: Example for Y control with EKEQFCBA box

F1/F2

EKEQFCBA EKEKXV*
Digital signal
to steer EEV Treturn

Only for
commissioning

Tsupply

AIR HANDLING UNITS


Input signal from sensors

Outdoor unit compatibility More than 3 control boxes


RYYQ8T > RYYQ54T connected to same outdoor
DX coil

RXYQ8T > RXYQ54T


RWEYQ8T9 > RWEYQ30T9
ERQ100 > ERQ250 1
(1) Only available in 1 to 1 combination
Two control boxes connected
to Outdoor 1 to circuits 1
Connection restrictions and 2 of coil A. Control box 3
DX coil

Connection Ratio between 90-110% connected to outdoor 2 and


OK circuit 3 of coil A.
Connection Ratio ERQ: between 50-110%
CR= Σ IU CC = Σ (CF x EKEXV CC)1-3
Σ OU CC Σ OU CC

CF is the correction factor


CC is the capacity class Two control boxes on coil A
DX coil

(2 circuits) and another control


OK box on coil B (1 circuit).
Both connected to same
DX coil

outdoor

39
Air handling application

Multi application examples


Multi application layout #1: Example for Z control with EKEQMCBA box and no VRV indoor units

F1/F2
Mandatory

EKEQMCBA EKEKXV*
Digital signal to steer EEV

OR

ROOM

KRCS01-1B

n control boxes
Input signal from sensors
OR

Outdoor unit compatibility More than 3 control boxes


RYYQ8T > RYYQ54T connected to same outdoor
OK
DX coil

RXYQ8T > RXYQ54T


RWEYQ8T9 > RWEYQ30T9
EKEQMCBA control box Two control boxes connected
ERQ100 > ERQ250 1 to Outdoor 1 to circuits 1
EKEQDCB control box and 2 of coil A. Control box 3
DX coil

connected to outdoor 2 and


(1) Only available in 1 to 1 combination
OK circuit 3 of coil A.
Connection restrictions
Connection Ratio between 90-110%
Connection Ratio ERQ: between 50-110%
Two control boxes on coil A
CR= Σ IU CC = Σ (CF x EKEXV CC)1-n
DX coil

(2 circuits) and another control


Σ OU CC Σ OU CC
OK box on coil B (1 circuit).
Both connected to same
DX coil

CF is the correction factor


CC is the capacity class
outdoor

40
Air handling application

Multi application layout #2: Example for Z control with EKEQMCBA box and VRV indoor units

F1/F2
Mandatory

EKEQMCBA EKEKXV*
Digital signal to steer EEV

OR

ROOM

KRCS01-1B

AIR HANDLING UNITS


n control boxes

Input signal from sensors


OR

Outdoor unit compatibility More than 3 control boxes


Not mandatory to have VRV DX indoors: connected to same outdoor
OK
DX coil

RYYQ8T > RYYQ54T


RXYQ8T > RXYQ54T
RWEYQ8T9 > RWEYQ30T9 Two control boxes connected
Mandatory to have VRV DX indoors: to Outdoor 1 to circuits 1
REYQ8T > REYQ54T and 2 of coil A. Control box 3
DX coil

connected to outdoor 2 and


Connection restrictions OK circuit 3 of coil A.
Connection Ratio between 50-110%
CR= Σ IU CC = Σ (CF x EKEXV CC)1-n
Σ OU CC Σ OU CC
Two control boxes on coil A
coil
DXcoil

RULES: Σ EKEXV CC: 0-60%  Σ IU CC: 50-110% (2 circuits) and another control
DX

OK box on coil B (1 circuit).


CF is the correction factor
Both connected to same
coil
coil

CC is the capacity class


DXDX

outdoor

41
Options & accessories

Options &
accessories

FILTERS

VH ELECTRICAL HEATER FOR VAM

CONTROLS

42
User-friendly wired remote contoller with premium design

White Silver Black

OPTIONS & ACCESSORIES


BRC1H519W/S/K
›› Sleek and elegant design
›› Intuitive touch button control
›› 3 color versions
›› Advanced settings and monitoring can
be easily done via your smartphone Advanced user settings Field settings
›› Flat back for easy wall installation
›› Compact to fit standard size socket boxes

DIRECT INTEGRATION
WITH DAIKIN VENTILATION PRODUCTS

43
Heat Recovery Ventilation - Modular L (Smart)

ALB02LBS/RBS ALB03LBS/RBS ALB04,05LBS/ ALB06,07LBS/ VAM VAM VAM


RBS RBS 150FC 250FC 350J

BRC301B61
• • • • • • •
Individual control systems

VAM wired remote control


Madoka
BRC1H519W (Glossy white) / BRC1H519S (Silver Metallic) /
BRC1H519K (Black matte) • • • • • • •
User-friendly wired remote controller with premium design
BRC1E53A/B/C
Wired remote control with full-text
interface and back-light
• • • • • • •
BRC1D52
Standard wired remote control with weekly timer • • • • • • •
DCC601A51
intelligent Tablet Controller • • • • • • •
Centralised control

DCM601A51
intelligent Touch Controller • • • • • • •
systems

DCS302C51
Central remote control • • • • • • •
DCS301B51
Unified ON/OFF control • • • • • • •
DST301B51
Schedule timer • • • • • • •
DCM601A51
• • • • • • •
Management System
& Standard protocol

intelligent Touch Manager


EKMBDXA
• • • • • • •
interface
Building

Modbus interface
DMS502A51
BACnet Interface • • • • • • •
DMS504B51
LonWorks Interface • • • • • • •
Coarse 55% (G4) ALF02G4A ALF03G4A ALF05G4A ALF07G4A

ePM10 75% (M5) ALF02M5A ALF03M5A ALF05M5A ALF07M5A

ePM10 70% (M6) EKAFVJ50F6

ePM1 50% (F7) ALF02F7A ALF03F7A ALF05F7A ALF07F7A


Filters

ePM1 55% (F7) EKAFVJ50F7

ePM1 70% (F8) EKAFVJ50F8

ePM1 80% (F9) ALF02F9A ALF03F9A ALF05F9A ALF07F9A

High efficiency filter

Replacement air filter

Rail
Mechanical
accessories

ALA02RLA ALA03RLA ALA05RLA ALA07RLA

Rectangular to round duct transition ALA02RCA ALA03RC ALA05RCA ALA07RCA

Separate plenum
BRYMA200 BRYMA200 BRYMA200 BRYMA200
CO2 sensor (preliminary) (preliminary) (preliminary) (preliminary)
BRYMA65

Electrical heater ALD02HEFB ALD03HEFB ALD05HEFB ALD07HEFB VH1B VH2B VH3B

Silencer (900mm depth) ALS0290A ALS0390A ALS0590A ALS0790A

Wiring adapter for external monitoring/control


Electrical accessories

KRP2A51 KRP2A51 KRP2A51 (2)


(controls 1 entire system)
Adapter PCB for humidifier KRP50-2 KRP50-2 KRP1C4 (5)

Adapter PCB for third party heater BRP4A50 BRP4A50 BRP4A50A (4)

External wired temperature sensor

Adapter PCB Mounting plate


Notes
(1) Do not connect the system to DIII-net devices LONWorks interface, BACnet interface, …; (intelligent Touch Manager, EKMBDXA are allowed)
(2) Installation box KRP1BA101 needed
(3) Adapter PCB mounting plate needed, applicable model can be found in the table above
(4) 3rd party heater and 3rd party humidifier cannot be combined
(5) Installation box KRP50-2A90 needed
(6) Contains 1 plenum and can be used for half side of the unit (up to 4 plenums can be used on 1 unit)
(7) Available only with optional plenum

44
Energy reclaim ventilation - VAM Energy reclaim ventilation VKM Air handling unit applications

VAM VAM VAM VAM VAM VAM VKM VKM VKM EKEQ EKEQ EKEQ
500J 650J 800J 1000J 1500J 2000J 50GB (M) 80GB (M) 100GB (M) FCBA (1) DCB (1) MCBA (1)

• • • • • •
• • • • • • • • • • • •

• • • • • • • • • • • •
• • • • • • • • • • • •
• • • • • • • • • • • •
• • • • • • • • • • • •
• • • • • • • • •
• • • • • • • • •
• • • • • • • • •
• • • • • • • • • • • •
• • • • • • • • • • • •
• • • • • • • • •
• • • • • • • • •

EKAFVJ50F6 EKAFVJ65F6 EKAFVJ100F6 EKAFVJ100F6 EKAFVJ100F6 x2 EKAFVJ100F6 x2

EKAFVJ50F7 EKAFVJ65F7 EKAFVJ100F7 EKAFVJ100F7 EKAFVJ100F7 x2 EKAFVJ100F7 x2

EKAFVJ50F8 EKAFVJ65F8 EKAFVJ100F8 EKAFVJ100F8 EKAFVJ100F8 x2 EKAFVJ100F8 x2

KAF242H80M KAF242H100M KAF242H100M

OPTIONS & ACCESSORIES


KAF241H80M KAF241H100M KAF241H100M

EKPLEN200 (6) EKPLEN200 (6)

BRYMA65 BRYMA65 BRYMA100 BRYMA100 BRYMA200 BRYMA200 BRYMA65 BRYMA100 BRYMA200

VH3B VH4B / VH4/AB VH4B / VH4/AB VH4B / VH4/AB VH5B(7) VH5B(7)

KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) BRP4A50A (4) BRP4A50A (4) BRP4A50A (4)

KRP1C4 (5) KRP1C4 (3/5) KRP1C4 (5) KRP1C4 (5) KRP1C4 (3/5) KRP1C4 (3/5) BRP4A50A (4) BRP4A50A (4) BRP4A50A (4)

BRP4A50A (4) BRP4A50A (3/4) BRP4A50A (4) BRP4A50A (4) BRP4A50A (3/4) BRP4A50A (3/4) BRP4A50A (4) BRP4A50A (4) BRP4A50A (4)

KRCS01-1

EKMP65VAM EKMPVAM

45
ALD-HEFB

Electrical heater for


Modular L smart
›› Total solution for fresh air with Daikin supply of both Modular L
Smart and electrical heaters
›› Increase comfort in low outdoor temperature thanks to the
heated outdoor air
›› Integrated electrical heater concept
(no additional accessories required)
›› Standard dual flow and temperature sensor
›› Heater only consumes what is required to pre-heat to the desired
minimum fresh air temperature; thus saving energy

Electrical heater for Modular L Smart (ALD) 02HEFB 03HEFB 05HEFB 07HEFB
Capacity kW 1,5 3 7,5 15
Connectable Modular L Smart size 02 03 04, 05 06, 07
Supply voltage 230V,1ph 400V,3ph
Output current (maximum) (A) 6,6 13,1 10,9 21,7

15k ohms at -20 °C 16k ohms at -20 °C 17k ohms at -20 °C 18k ohms at -20 °C
Temperature sensor
10k ohms at +10 °C 10k ohms at +10 °C 10k ohms at +10 °C 10k ohms at +10 °C

Temperature control range - 20 °C to 10 °C

Control fuse Mini Circuit Breaker 6 A

"Yellow = Airflow fault


LED indicators
Red = Heat ON”

Mounting holes Depends on duct size


Maximum ambient adjacent to terminal box 30°C (during operation)
Auto high temp. cutout 75°C Pre-set
Man. reset high temp.cutout 120°C Pre-set
Width (mm) 470 620 720 920
Depth (mm) 370 370 370 370
Height (mm) 193 243 343 443

46
VH

Electrical heater for VAM


›› Total solution for fresh air with Daikin supply of both VAM
and electrical heaters
›› Increased comfort in low outdoor temperature thanks
to the heated outdoor air
›› Integrated electrical heater concept (no additional accessories
required)
›› Standard dual flow and temperature sensor
›› Flexible setting with adjustable setpoint
›› Increased safety with 2 cut-outs: manual & automatic
›› BMS integration thanks to:
- Volt free relay for error indication
- 0-10VDC input for setpoint control
ʯʯ Heateronlyconsumeswhatisrequiredtopre-heattothedesired
minimum fresh air temperature; thus saving energy

VH 1B 2B 3B 4B 4/AB 5B(1) OPTIONS & ACCESSORIES


Capacity kW 1 1.5 2.5 2.5
Duct diameter mm 100 150 200 250 300
Connectable VAM VAM150FC VAM250FC VAM350,500J VAM650J, VAM800J, VAM1000J VAM1500J, VAM2000J
ELECTRICAL HEATER FOR VAM VH (VH)
Supply voltage 220/250V ac 50/60 Hz. +/-10%
Output current (maximum) 19A at 40°C (ambient)
Temperature sensor 5k ohms at 25°C (table 502 1T)
Temperature control range 0 to 40°C / (0-10V 0-100%)
Control fuse 20 x 5mm 250mA
LED indicators Power ON - Yellow
Heater ON - Red (solid or flashing, indicating pulsed control)
Airflow fault - Red
Mounting holes 98mm x 181mm centres 5 mm ø holes
Maximum ambient adjacent to terminal box 35°C (during operation)
Auto high temp. cutout 100°C Pre-set
Man. reset high temp. cutout 125°C Pre-set
Run relay 1A 120V AC or 1A 24V DC
BMS setpoint input 0-10VDC
(1) Available only with the optional plenum

47
We’re here to help you!
Online and offline

http://literature.daikinpromoshop.eu

Benefits
We care icons
Seasonal efficiency, smart use of energy Econo mode
Seasonal efficiency gives a more realistic indication on how This function decreases the power consumption so that other
efficient air conditioners operate over an entire heating or cooling applicances that need large power consumption can be used.
season. This function is also energy saving.
Auto-cleaning filter Movement sensor
The filter automatically cleans itself. Simplicity of upkeep means The sensor detects whether someone is in the room. When
optimum energy efficiency and maximum comfort without the the room is empty, the unit switches to economy mode after
need for expensive or time-consuming maintenance. 20 minutes and restarts when a person enters the room.
Inverter technology
Inverter compressors continuously adjust compressor speed to
actual demand. Fewer power-consuming starts and stops result
in decreased energy consumption (up to 30%) and more stable
Home leave operation
During absence, the indoor temperature can be maintained at
a certain level.
A big step setting the
temperatures.
2 area intelligent eye
Air flow is sent to a zone other than where the person is located
at that moment. Detection is done in 2 directions: left and right. If
no people are detected, the unit will automatically switch over to
the energy-efficient setting.
Fan only
The air conditioner can be used as fan, blowing air without
cooling or heating. new heat pump standard General catalogue
3 area intelligent eye Free cooling
Air flow is sent to a zone other than where the person is located By exploiting the low external air temperatures to cool the water,
at that moment. Detection is done in 3 directions : left, front and

2018
free cooling reduces the load on the compressors and decreases
3 right. If no people are detected, the unit will automatically switch considerably the annual operating costs during the cold season.
over to the energy-efficient setting and eventually switch off.
Floor & presence sensor
Energy saving during operation standby The presence sensor directs the air away from any person
Current consumption is reduced by about 80 % when operating detected in the room, when the air flow control is on. The floor
on standby. sensor detects the average floor temperature and ensures an even
temperature distribution between ceiling and floor.
GENERAL C ATA L O G U E 2 0 1 8

Night set mode Solar panel


Saves energy, by preventing overcooling or overheating during Take advantage of solar power. Easily connect your hot water
night time. storage to solar collectors on your roof.

Comfort
Comfort mode Draught prevention
The unit automatically changes the angle of the air discharge louvre When starting to warm up or when the thermostat is off, the air
depending on the mode. In cooling operation the air will be directed discharge direction is set horizontally and the fan to low speed, to
rather upwards to avoid cold draught, while in heating operation the prevent draught. After warming up, air discharge and fan speed
air will be directed rather downwards to avoid cold feet. are set as desired.
Powerful mode Auto cooling-heating changeover
If the temperature in the room is too high/low, it can be cooled Automatically selects cooling or heating mode to achieve
down/heated quickly by selecting the ‘powerful mode’. After the the set temperature (heat pump types only).
powerful mode is turned off, the unit returns to the preset mode.

Impossible to hear Indoor unit silent operation


Practically inaudible: the unit runs so quietly, you will almost To ensure a quiet environment for studying or sleeping the user
forget it is there. can lower the operation sound of the indoor unit by 3 dB(A) via
remote control.
Night quiet mode (cooling only)
Whisper quiet Lowers the operation sound of the outdoor unit automatically
Daikin units are whisper quiet. (with sound levels as low as 19dBA) at night.
Installer has to make special setting on outdoor unit or wired

Outdoor unit silent operation


remote controller, depending on model.
The new generation Daikin Altherma 3
To ensure a quiet environment for the neighbourhood the user Radiant heat
can lower the operation sound of the outdoor unit by 3 dB(A) via
remote control.
The front panel of the indoor unit radiates additional heat to add
to your comfort on cold days HE M
IN T

IS

High performance - The 3rd Generation of Daikin Altherma is


S I ON

Fresh hot water


Comfortable sleeping mode The structure of thermal store ensures optimal water hygiene and taking you beyond the imaginable with its performance: A+++
JO

Increased comfort function that follows a specific temperature eliminates the risk of bacteria and legionella. Rest assured that
fluctuation rhythm. your hot water is fresh and safe Seasonal efficiency and operation range down to -25°C.

Air flow Easy to install - The floor standing unit only has a 60 cm2
footprint and you can choose for white or silver-grey colour. HE M HE M
3-D Air flow
IN T
IN T

IS
IS

Ceiling soiling prevention This function combines Vertical and Horizontal auto-swing to
S I ON
S I ON

A special function prevents air blowing out too long in horizontal circulate a stream of cool/warm air right to the corners of even
position, to prevent ceiling stains. large spaces. Easy to control - Fully digital, the Daikin Altherma 3 can be
JO
JO

Vertical auto swing Horizontal auto swing


controlled from everywhere with an app or a home control system.
Possibility to select automatic vertical moving of the air discharge Possibility to select automatic horizontal moving of the air
louvre, for uniform air flow and temperature distribution. discharge louvre, for uniform air flow and temperature distribution.

Auto fan speed


Fan speed steps
For more information: www.daikin.eu
Automatically selects the necessary fan speed to reach or maintain
the set temperature. Allows to select up to the given number of fan speed.
Daikin Europe N.V. participates in the Eurovent Certified
Performance programme for Liquid Chilling Packages and
Individual flap control Fireplace logic Hydronic Heat Pumps, Fan Coil Units and Variable Refrigerant
Flexible installation thanks to the possibility of easily closing When installed close to a heating device (e.g. fireplace or oven) Flow systems. Check ongoing validity of certificate:
one flap via the wired remote controller, to suit any new room and the set temperature is reached, the fan keeps on running to www.eurovent-certification.com
configuration. Optional closure kits are available as well. have an even temperature throughout the whole house
ECPEN18-500A
Coanda effect - cooling Grid eye sensor The present publication is drawn up by way of information only and does not constitute an offer binding upon
The Coanda effect optimises the airflow in cooling mode. By using The grid eye sensor determines the current room temperature and Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No
specially designed flaps, a more focused airflow allows a better distributes air evenly throughout the room before switching to an express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its
temperature distribution throughout the whole room. airflow pattern that directs warm or cool air to areas that need it. content and the products and services presented therein. Specifications are subject to change without prior notice.
Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from
Coanda effect - heating or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.
The Coanda effect optimises the airflow in heating mode. By using Printed on non-chlorinated paper. Prepared by Schaubroeck
specially designed flaps, a more focused airflow allows a better
temperature distribution throughout the whole room.

133651_ECPEN_500A_v02.indd 1 28/02/18 07:42

48
Tools and
platforms

Literature overview 50
Supporting tools, software and apps 52

TOOLS & PLATFORMS

49
Commercial market - literature overview
for professional network
Solution
guides:

Reference
books:

Product VRV IV range Keep looking


i
VRV IV i-series Sky Air Water-to-air
profiles: VRV IV
Detailed VRV IV you’ll never find me Main benefits, A-series heat pump
standards and application examples Our mission Water-to-air
360° efficiency Achieve
the lowest Main benefits heat pump Detailed info on
technologies and specs of VRV IV environmental
using water as a heat source

impact and specs VRV IV W-series,


benefits. Main i-series product range application
VRV IV heat pumps for indoor installation

features and
207 116 examples,
specs of VRV IV
technical
VRV IV heat recovery, heat pump, replacement

product range VRV IV S-series system design


and water cooled
Introducing the new Sky Air A-series with
ultra-efficient Bluevolution R-32 technology Scale up your expectations

Keep looking
you’ll never find me Main benefits, background
206 application examples
and specs of VRV IV 209

Compact VRV IV heat pumps


for residential and light commercial applications
S-series product range
208

Focus Replacement Infrastructure cooling


topics: Technology ON
TINUOUS O Clear installer benefits
C

PE
RELIABLE,

Replacement why to choose Daikin for


RATION

Infrastructure
technology Clear installer benefits cooling solution
for installers
of VRV replacement infrastructure cooling
technology

› For server rooms, telecom shelters, laboratories, IT applications

214 140
The quick and quality way of upgrading R-22 and R-407C systems

Product
Real time clock

Real time clock with auto update to daylight saving


time

Supports multiple languages


Possibility to individually restrict menu
functions/buttons

› Restrict some of all functions on the remote


control to void misuse in e.g. hotels, shops, offices
Wired Remote Control Split, Sky Air, VRV, Chillers,
Refrigeration, Daikin Altherma
RTD modbus interface
flyers: Detailed info on BRC1E- Detailed info on RTD
Other features
› English, German, French, Spanish, Italian,
Portuguese, Greek, Dutch, Russian, Turkish › Built-in back-up power. When a power failure occurs,
and Polishr (BRC1E52A) all settings remain stored up to 48 hours

› English, German, Czech, Croation, Hungarian, › Backlight display


Romanian, Slovenian, Bulgarian, Slovak, Serbian,
Albanian (BRC1E52B)

Modbus
Specifications / Functions
Specifications
Dimensions (HxWxD)
Display size (HxW)
BRC1E52A / BRC1E52B
3.120x120x19 mm40
43.2x68.85 mm
User friendly
remote control 52A/B remote control Interface controls and applications
with contemporary
LCD
Type Full dot (160x255)
Colour
Cover for operation part
Max. wiring length
Fresh white
No
500m
RTD
design
Connectable indoor units All VRV® and Sky Air® indoor units

Functions BRC1E52A / BRC1E52B


Set sensor behavior —
Temperature range limit —
Energy saving
functions
Setback function
Set point auto reset
—
— BRC1E52A/B
Off timer —
Multilingual display English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, Polishr English, German, Czech, Croation, Hungarian, Romanian, Slovenian, Bulgarian, Slovak, Serbian, Albanian
Help menu —
Room temperature display —
Display
Clock (time display) Real time clock with auto update to daylight saving time
Backlight —
Contrast adjustment —
Weekly schedule timer 3
Timer
Holiday function —
Key lock —
Access control Restrict menus Each menu individually
Restrict buttons Each button individually (ON/OFF, operation mode selector, temperature adjustment, fan speed / air flow direction)
Memory Built-in back-up power When a power failure occurs, all settings remain stored up to 48 hours

› Easy to use: all main functions directly accessible › Set up to 3 independent schedules, so the user can
easily change the schedule himself throughout the
Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor) › Easy commissioning: intuitive interface for advanced year (e.g. summer, winter, mid-season)
menu settings
› Real time clock with auto update to daylight saving
FSC › Optimise your air conditioning system by activating a time
series of energy saving functions (temperature range
ECPEN15 - 306 180 · 11/14 limit, setback function, off timer, …) › Supports multiple languages Integration of Daikin portfolio in BMS system via Modbus

308
The present publication is drawn up by way of information only and does not constitute an offer binding upon

306
Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its › Keep track of your energy consumption with the › Possibility to individually restrict menu functions › Indoor unit control › Retail applications
content and the products and services presented therein. Specifications are subject to change without prior notice.
kWh indication showing an indicative electricity via 0~10 volt, dry contact › Hotel applications
Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from
or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V. consumption › When a power failure occurs all settings remain stored or resistance contact › IT applications
The present publication supersedes ECPEN12-306. Printed on non-chlorinated paper. up to 48 hours thanks to the built-in backup power › Heating interlock
› Alarm signal

Product Sky Air Catalogue VRV Catalogue Ventilation Catalogue


catalogues: Sky Air
Detailed technical
VRV
Detailed technical
Ventilation
Detailed info on
Product catalogue 2017
for professionals
information & benefits Product catalogue 2018
for professionals
information & benefits of Product catalogue 2018
for professionals
Ventilation products
on Sky Air/Ventilation/ the VRV total solution
Biddle Air Curtain/Control
systems/AHU
R-32
IS AN
INDUSTRY
REVO
LUTIO
BE PART N.
OF IT. Including

ErP1
THE BEST OUR BIM
PART
NER VISIT
TION new
Minimum running costs, FOR GREE
N APPLICA
ON
Modular L
liant ING SUITE
Get ahead of competition maximum flexibility. comp BUILD AIKIN.E
U/BIM
Fresh air for the residential and commercial sector

100 200 203


Fast installation, top reliability, 202 SUPP
ORT WWW.D

Heat reclaim ventilation and air handling applications


perfect comfort.

50
Tools and platforms

for your customers


Commercial Solutions Green Building Solutions
Daikin offers solutions for Green building
Clear building owner/investor
benefits why to choose Daikin
Commercial solutions
solutions
for small to large applications
commercial applications
for a green building, with
emphasis on BREEAM
365-days climate comfort for every business

216
100
Sustainable design
with Daikin HVAC-R systems

Reference
catalogue
Daikin commercial Hotel Solutions
and industrial Hotel solutions
Clear building owner/investor
references for hotel owners
benefits why to choose Daikin
Heating - air conditioning - hot water - ventilation - refrigeration - control
for a hotel
218
213

Intelligent Touch Manager Tablet


DCC601A51
Detailed benefits of Detailed benefits of DCC601A51
Control systems

Intelligent Touch
Intelligent Touch Manager intelligent
Tablet Controller and Daikin Cloud Service
with cloud connection
Manager

302 303
Mini Building Management System Your business at your fingertips

SPLIT, SKY AIR, VRV, CHILLERS Replacement technology


Clear building owner/investor
benefits of replacement
The phase-out period for
R-22 is over.
Act now!
technology

Avoid loss of business and replace your air conditioning


system now!

215

Sky Air product leaflets VRV product leaflets


Concealed
Single page leaflet with the Single page leaflet with the
floor standing
unit main benefits and technical Concealed
ceiling unit
with medium
main benefits and technical
specifications of each specifications of each individual
FNQ-A, FXNQ-A

ESP
FBQ-D, FXSQ-A

individual Sky Air unit. Ideal for VRV unit. Ideal for quotations
quotations
Designed to be concealed in walls Optimum comfort guaranteed no matter the
Home leave
Home leave length of ductwork or type of grilles
operation
operation › Ideal for installation in offices, hotels and residential › Discretely concealed in the wall, leaving only the
› Top efficiency in the market › Medium external static pressure up to 150Pa facilitates
applications suction and discharge grilles visible
› Automatic air flow adjustment function measures the using flexible ducts of varying lengths
› Its low height enables the unit to fit perfectly beneath › Requires very little installation space as the depth is
air volume and static pressure and adjusts it towards › Reduced energy consumption thanks to specially
a window only 200mm
Powerful mode the nominal air flow, whatever the length of duct, developed DC fan motor
Powerful mode › High ESP allows flexible installation
making installation easier and guaranteeing comfort. › Flexible installation, as the air suction direction can be
Moreover, the ESP can be changed via the wired altered from rear to bottom suction
remote control to optimize the supply air volume › Standard built-in drain pump increases flexibility and
Multi tenant
Multi tenant (FXSQ) › Slimmest unit in class, only 245mm installation speed
(FXNQ-A)
› Discretely concealed in the ceiling: only the suction › No optional adapter needed for DIII-connection, link
and discharge grilles are visible your unit into the wider building management system
› Low sound level

TOOLS & PLATFORMS

Technical documentation:
All latest Daikin catalogues are available in
a convenient library on the internet:
www.daikineurope.com/support-and-manuals/catalogues

51
Supporting www.daikineurope.com/
support-and-manuals/

tools, software and apps software-downloads

New web based Xpress selection software


Making selection easy, anytime, anywhere

›› Web & cloudbased access to your projects from ›› No need to do local installation
anywhere, at any time… ›› No tool updates required
›› Platform (Windows, Mac, …) and hardware (always latest version available)
(laptop, desktop, tablet) independent ›› Possibility to copy / share projects
›› Re-engineered GUI for maximum easy of use

Easy selection, anytime, anywhere

Main functions

Toolbox Working area

Detailed properties

Import / Export / Delete indoors

Easy editing of piping Intuitive interface

Clear wiring overview, easy to make control groups Clear overview of control groups and central controls

52
Other selection software
VRV Pro Ventilation Xpress

Enables VRV air conditioning systems to be Selection tool for ventilation devices (VAM, VKM). The
engineered in a precise and economical way, taking selection is based on given supply/extract airflows
into account the complex piping rules. Moreover, it (including fresh up and given ESP of supply/extract
ensures optimum operating cycles and maximum ducting):
energy efficiency. ›› Determines size of electrical heaters
›› Accurate heat load calculation ›› Visualisation of psychrometric chart
›› Precise selection based on peak loads ›› Visualisation of selected configuration
›› Energy consumption indication ›› Required field settings mentioned in the report

Webbased ASTRA selection NEW WAGO selection tool NEW


for air handling units
The WAGO Selection Tool is specifically designed to
A powerful tool to select the right Air Handling Units select the optimal WAGO I/O system for your needs.
for your needs.
›› 3D interface ›› Easy selection of WAGO materials
›› quick selection procedures ›› Material list creation
›› new print-out possibilities and report shapes ›› Time saving
• Includes wiring schemes
• Contains commissioning/preset data for TOOLS & PLATFORMS

53
Plug-ins and third-party software tools
Building Information Modelling www.daikin.eu/
(BIM) support
bim
›› BIM improves efficiency of design and build phase
›› Daikin is among the first
to supply a full library of BIM objects
for its VRV products

VRV CAD 2D
http://www.
›› Displays VRV pipe design on a Autocad 2D
floorplan daikineurope.
›› Improves project management com/autocad/
›› Accurately calculates the pipe dimensions and
refnets index.jsp
›› Determines the outdoor unit size
›› Validates VRV pipe rules
›› Accounts for the extra refrigerant charge,
including a max room concentration check

Energy simulation and design aid tools

Seasonal simulator

›› The Seasonal Simulator is an innovative software


tool that calculates and compares potential
seasonal efficiency ratings.
›› This user-friendly tool compares various Daikin
systems, annual power consumption, CO2
emissions, and much more, to present an accurate
ROI calculation in a matter of minutes.

Psychrometrics diagram NEW

›› The Psychrometrics Diagram Viewer demonstrates


the changing properties of moist air.
›› With this tool, users can choose two points with
specific conditions, plot them on the diagram and
select actions to change the conditions, i.e. heat,
cool and mix air.

54
Service tools
Error code app

Quickly know the meaning of fault codes, for each


product family and the potential cause

D-Checker

D-checker is a software application used to record


and monitor operation data of Daikin applied, split,
Multi-split, Sky-air units, Daikin Altherma LT, ground
source heat pump, Hybrid, ZEAS, Conveni-pack &
R410A Booster unit

Bluetooth adaptor NEW

Monitoring of Split, Sky Air and VRV data via any


bluetooth device Diagnosis of the Bluetooth system possible:
›› No need to access the outdoor unit
• Connects with D-Checker software (for laptops)
• Connects with monitoring app (for tablets or
smartphones) Computer with Bluetooth

VRV Service-Checker

›› Connected via F1/F2 bus to check multiple


systems at the same time
›› Connection of external pressure sensors possible

Online support Internet


Find our solution for different applications:
NEW Business portal
Supermarket Technical
Restaurant
›› Experience our new extranet that
thinks with you at my.daikin.eu Hotel Store & Bank Industry
shop
›› Find information in seconds
Sport &
via a powerful search Home Office Leisure
›› Customise the options so you
see only info relevant for you
›› Access via mobile device or desktop

my.daikin.eu
ON ›› Get more commercial details on our flagship
THE products via our dedicated minisites
R OA D
AT ›› See our references
CUSTOME
RS
TOOLS & PLATFORMS

HOTEL PORTA FIRA


AT THE OFFICE

www.daikineurope.com/references

55
56
Technical
drawings

ALB-RBS / LBS 58
VAM-J/FC 64
VKM-GB(M)

TECHNICAL DRAWINGS

57
VIEW ALL ALB-LBS DRAWINGS
ON MY.DAIKIN.EU
Detailed technical drawings

ALB02RBS/LBS

CONDENSATE
OUTLET 1/4”G

TOP VIEW BOTTOM VIEW

ELECTRIC
SWITCH BOX

ALB03RBS/LBS

CONDENSATE BOTTOM VIEW


OUTLET 1/4”G

TOP VIEW

ELECTRIC
SWITCH
BOX

58
VIEW ALL ALB-RBS DRAWINGS
ON MY.DAIKIN.EU
Detailed technical drawings

ALB04RBS/LBS

CONDENSATE
OUTLET 1/4”G

TOP VIEW

BOTTOM VIEW

ELECTRIC
SWITCH
BOX

ALB05RBS/LBS

CONDENSATE
OUTLET 1/4”G

TOP VIEW
BOTTOM VIEW

ELECTRIC
SWITCH
TECHNICAL DRAWINGS

BOX

59
VIEW ALL ALB-LBS DRAWINGS
ON MY.DAIKIN.EU
Detailed technical drawings

ALB06RBS/LBS

CONDENSATE
OUTLET 1/4”G

TOP VIEW

BOTTOM VIEW

ELECTRIC
SWITCH BOX

ALB07RBS/LBS

CONDENSATE
OUTLET 1/4”G

TOP VIEW

BOTTOM VIEW

ELECTRIC
SWITCH
BOX

60
VIEW ALL ALB-RBS DRAWINGS
ON MY.DAIKIN.EU
Detailed technical drawings

ALB02RBS/LBS

The diagram shows the available external pressure for the duct
system given an airflow.
SFPv = Specific Fan Power (W/m3/s)
The SFPv curves are referring to the complete unit. Moreover, it
includes power to both supply and extract fan divided by either
the supply or extract volume whichever is the greater.

Nominal working point

ALB03RBS/LBS

The diagram shows the available external pressure for the duct
system given an airflow.
SFPv = Specific Fan Power (W/m3/s)
The SFPv curves are referring to the complete unit. Moreover, it
includes power to both supply and extract fan divided by either
the supply or extract volume whichever is the greater.
TECHNICAL DRAWINGS

Nominal working point

61
VIEW ALL ALB-LBS DRAWINGS
ON MY.DAIKIN.EU
Detailed technical drawings

ALB04RBS/LBS

The diagram shows the available external pressure for the duct
system given an airflow.
SFPv = Specific Fan Power (W/m3/s)
The SFPv curves are referring to the complete unit. Moreover, it
includes power to both supply and extract fan divided by either
the supply or extract volume whichever is the greater.

Nominal working point

ALB05RBS/LBS

The diagram shows the available external pressure for the duct
system given an airflow.
SFPv = Specific Fan Power (W/m3/s)
The SFPv curves are referring to the complete unit. Moreover, it
includes power to both supply and extract fan divided by either
the supply or extract volume whichever is the greater.

Nominal working point

62
VIEW ALL ALB-RBS DRAWINGS
ON MY.DAIKIN.EU
Detailed technical drawings

ALB06RBS/LBS

The diagram shows the available external pressure for the duct
system given an airflow.
SFPv = Specific Fan Power (W/m3/s)
The SFPv curves are referring to the complete unit. Moreover, it
includes power to both supply and extract fan divided by either
the supply or extract volume whichever is the greater.

Nominal working point

ALB07RBS/LBS

The diagram shows the available external pressure for the duct
system given an airflow.
SFPv = Specific Fan Power (W/m3/s)
The SFPv curves are referring to the complete unit. Moreover, it
includes power to both supply and extract fan divided by either
the supply or extract volume whichever is the greater.
TECHNICAL DRAWINGS

Nominal working point

63
VIEW ALL VAM-FC TECHNICAL VIEW ALL VAM-J TECHNICAL
DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM150FC
VAM150FA
Maintenance space for the heat exchange elements, the air filters and fans
Switch box

Ceiling hook
Inspection hole 4-14x40 oval hole
285 Ø 450

269 Supply air fan

120~250
600
Maintenance over 104 120.3
149

20
67

SA OA
Supply air to room 124 164

124
Fresh air from outdoors

288
509

560
(Outdoor air)
288

164
RA EA
Return air from room Exhaust air to outdoors
8 Sealing Sealing
8

120 104 718

20
149
Damper plate
Exhaust air fan
(Maintenance cover) Exhaust spacer
(Switch box)
145 760 145

Ø200
Ø97
Heat exchange elements Air filters

NOTE
1 Be sure to provide the inspection hole (450x450 mm) to inspect the air filters, the exchange elements and fans.

3TW27874-1

VAM250FC
VAM250FA
Maintenance space for the heat exchange elements, the air filters and fans
Switch box

Ceiling hook
Inspection hole
285 Ø 450 4-14x40 oval hole

269 Supply air fan


120~250
600

149 Maintenance over


104 120.3
20
67

SA
OA
Supply air to room
124 164

124

Fresh air from outdoors


288
509

560
288

(Outdoor air)
164

RA EA
Return air from room Exhaust air to outdoors
8
Sealing Sealing
8

120 104 718


20

149
Damper plate
Exhaust air fan
(Maintenance cover)
(Switch box)
145 760 145
Ø200
Ø97

Heat exchange elements Air filters

NOTE
1 Be sure to provide the inspection hole (450x450 mm) to inspect the air filters, the exchange elements and fans.

3TW27884-1

64
VIEW ALL VAM-J TECHNICAL VIEW ALL VAM-FC TECHNICAL
DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM350-500J
VAM350-500J

Ceiling hook
4 - 12 x 40mm oblong hole Damper panel
305
304.8 Exhaust air fan
10 284.8 10 1045 112.3
112
112.3
122 Sealing material

22

6
Sealing material
RA
Return air from room
EA

291.6
292
137
126.8
Exhaust air to outdoors

417
126.2
126
Exhaust air Room air 162.8
173

899.4

891.4
834
899

866

891
162.8
173
SA

125.4
125
Sealing material

417
126.8
137
Supply air to room

290.8
291
Supply air
OA
Supply air fan
Fresh outdoor air
Outdoor air Sealing material

191.4
190
22
112.3
122 112.3
122

200 - 300
Sealing material

≥675
Sealing material

475
Inspection hole

Maintenance space for the air filters, heat exchangers and fans
Switch box
900

Heat exchanger
84
78 1101
1113 84
78
6 6

Switch box
Ø 213
Ø 197

Maintenance cover Air filter


Notes :
1. To allow for the inspection of the air filters, heat exchangers, and fans, be sure to provide the inspection hole. 3D112815B

VAM650J
VAM650J

Ceiling hook
368 Exhaust air fan 4 - 12 x 40mm oblong hole Damper panel
1266
154
22

154 Sealing material


Sealing material
RA
EA
Return air from room
Exhaust air to outdoors
272
222

Room air 162


Exhaust air
(491)

211
941
920
949

211
493

162
220

Sealing material
272

SA
Supply air to room
OA
Supply air
Fresh outdoor air Supply air fan
186

Sealing material
22

Outdoor air
154
154 Sealing material
200 - 300
≥ 700

Sealing material
500

Inspection hole

Maintenance space for the air filters, heat exchangers and fans
Switch box
1100

Heat exchanger
83 1354 83

Switch box
Ø262
Ø245

TECHNICAL DRAWINGS

Maintenance cover Air filter


Notes
1.To allow for the inspection of the air filters, heat exchangers, and fans, be sure to provide the inspection hole.
3D112816B
65
VIEW ALL VAM-FC TECHNICAL VIEW ALL VAM-J TECHNICAL
DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM800-1000J
VAM800-1000J
Ceiling hook
368 4 - 12 x 40mm oblong hole Damper panel
Exhaust air fan 1266
154 154
Sealing material

22

6
Sealing material
RA

EA Return air from room


162

399
Exhaust air to outdoors

239

(606)
212 Room air

1204

1197
1172
(628)
Sealing material

207
162 SA

389
Supply air to room
OA Supply air
212
Fresh outdoor air Sealing material

Outdoor air Supply air fan

192
22
154 154
Sealing material

200-300
≥850
Sealing material
Inspection hole

Maintenance space for the air filters, heat exchangers and fans 650

Switch box
1100

Heat exchanger
83 1354 83

Sealing material
Ø262
Ø245

Maintenance cover Switch box


Air filter
Notes
1.To perform maintenance on the air filter, it is required to provide a service access panel.

3D112817C

VAM1500-2000J
VAM1500-2000J

731
Ceiling hook Damper panel
(2x) Exhaust air fan
4 - 14 x 40mm oblong hole
1266 (4x) Option EKPLEN200
384 150 Sealing material 150 345
20

Sealing material Sealing material


RA
EA
380 (4x)

Return air from room


395

Exhaust air to outdoors


250

(577)

Room air
1219

1172
1198
(599)

Exhaust air
218

SA
348

OA Supply air to room


Fresh outdoor air
Supply air
Outdoor air
198

Supply air fan


20

(2x)
345 150
Sealing material Sealing material 150 384
200 - 300
≥850

Sealing material Inspection hole


650

Maintenance space for the air filters, heat exchangers and fans
Switch box
1100

Heat exchanger
130 261 1354 261 130
26

Sealing material

Option KRP2A51
Mounting
Ø330
Ø350
405
621

plate Switch box

Option BRP4A50A
(10)
24

Maintenance cover Air filter


Notes:
1. To allow for the inspection of the air filters, heat exchangers, and fans, be sure to provide the inspection hole.
3D112818B

66
VAM150FC
VIEW ALL VAM-J TECHNICAL VIEW ALL VAM-FC TECHNICAL
DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM150FC

250 20m

200
15m
External static pressure [Pa]

150 Ultra-high

10m

100
High

Low 5m
50
Ø 100
Pipe length

0
0 50 100 150 200 250
Air flow rate [m³/h]

Notes
1. The fan speeds are valid for ·230·V, ·50·Hz power supply.

4D100379

TECHNICAL DRAWINGS

67
VIEW ALL VAM-FC TECHNICAL VIEW ALL VAM-J TECHNICAL
VAM250FC DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM250FC

250

200

Ultra-high
External static pressure [Pa]

Ø 150
150
Pipe length

High
100 40m

Low 30m

50 20m

10m

0
0 50 100 150 200 250 300
Air flow rate [m³/h]

Notes
1. The fan speeds are valid for ·230·V, ·50·Hz power supply.

4D100380

VAM350J
VAM350J

250

Ultra-high speed
200
External static pressure [Pa]
External static pressure [Pa]

300
250
150 250
200
200
100 150
150

100 UH15
100
50
50
50 UH8
Ø200 UH1
0 Duct lenght 0
450
150150 100 150 200 250 300 350 400 450 150 200 250 300 350 400

Air flow rate [m3/h]


Air flow rate [m3/h]
External static pressure [Pa]

High speed Low speed


External static pressure [Pa]

200 200

150 150

100 100
H15
50 50

H1 H8 L1
($" L15
0 0
150 200 250 300 350 400 450 ()"
L8
100 150 200 250 300 350 400 450

Air flow rate [m3/h] Air flow rate [m3/h]

Legend
Notes L1 = Low speed lower limit
1. The fan curves are determined with ·1/3· of the ESP on the outdoor side L8 = Low speed factory setting
(·EA & OA·), and ·2/3· of the ESP on the indoor side (·RA & SA·). L15 = Low speed upper limit
EA= Exhaust air H1 = High speed lower limit
Ultra-high speed H8 = High speed factory setting
OA= Outdoor air
High speed H15 = High speed upper limit
RA = Room air
Low speed UH1 = Ultra-high speed lower limit
SA = Supply air
UH8 = Ultra-high speed factory setting
2. Measured according to ·JIS B 8628 - 2003·
UH15 = Ultra-high speed upper limit

3D113493

68
VIEW ALL VAM-J TECHNICAL VIEW ALL VAM-FC TECHNICAL
DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VAM500J
VAM500J
250
200m
External static pressure [Pa] UH15
Ultra-high speed
200

External static pressure [Pa]


UH8 160m
250
H15

150 200
H8 120m
UH1
L15 150

100
80m 100
H1
UH15
L8 50
UH8
50
40m UH1
0
L1 250 300 350 400 450 500 550 600
Ø200
0 Duct length
150 200 250 300 350 400 450 500 550 600
Air flow rate [m³/h]
Air flow rate [m³/h]
External static pressure [Pa]

High speed Low speed

External static pressure [Pa]


200 200

150 150

100 100

50 50
H15
L15
H1 0 L1
0 H8 L8
200 250 300 350 400 450 500 550 600 150 200 250 300 350 400 450 500

Air flow rate [m³/h] Air flow rate [m³/h]


Legend

Notes L1= Low speed lower limit


1. The fan curves are determined with ·1/3· of the ESP on the outdoor side L8= Low speed factory setting
(·EA & OA·), and ·2/3· of the ESP on the indoor side (·RA & SA·). L15= Low speed upper limit
EA= Exhaust air H1= High speed lower limit
OA = Outdoor air H8= High speed factory setting
Ultra-high speed
RA = Room air H15= High speed upper limit
High speed UH1=Ultra-high speed lower limit
SA = Supply
2. Measured according to ·JIS B 8628 - 2003· Low speed UH8= Ultra-high speed factory setting
UH15= Ultra-high speed upper limit
3D113494

VAM650J
VAM650J
250
External static pressure [Pa]

200 UH15 Ultra-high speed


UH8 200m
250
External static pressure [Pa]

H15
150 160m
H8 200
UH1
L15 120m 150
100
H1
L8
800m 100 UH15
50
40m 50 UH8
L1 Ø250 UH1
0 Duct Length 0
250 350 450 550 650 750 350 450 550 650 750
Air flow rate [m³/h] Air flow rate [m³/h]
High speed Low speed
250 200
External static pressure [Pa]
External static pressure [Pa]

200
150
150
100
100
50
50 H15 L15
0 H1 H8 0 L1
L8
250 350 450 550 650 750 250 350 450 550 650 750
Air flow rate [m³/h] Air flow rate [m³/h]
Legend
Notes L1= Low speed lower limit
1. The fan curves are determined with 1/3 of the ESP on the L8= Low speed factory setting
TECHNICAL DRAWINGS

outdoor side (EA & OA), and 2/3 of the ESP on the indoor side (RA & SA). Ultra-high speed L15= Low speed upper limit
EA = Exhaust air H1= High speed lower limit
OA = Outdoor air High speed H8= High speed factory setting
RA = Room air H15= High speed upper limit
SA = Supply air UH1= Ultra-high speed lower limit
2. Measured according to JIS B 8628 - 2003 Low speed UH8= Ultra-high speed factory setting
UH15= Ultra-high speed upper limit
3D113495A

69
VIEW ALL VAM-FC TECHNICAL VIEW ALL VAM-J TECHNICAL
DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM800J

VAM800J
300
UH15 Ultra-high speed
250 350
H15 180m
External static pressure[PA]

300

External static pressure[PA]


200
UH8 150m
250
150 L15 120m
H8 200
UH1 90m UH15
100 150
H1
L8 60m 100
50
L1
30m 50 UH8
Ø250
UH1
0 Duct length
0
300 400 500 600 700 800 900 400 500 600 700 800 900
Air flow rate [m3/h] Air flow rate [m3/h]

High speed Low speed


300 250

External static pressure[PA]


External static pressure[PA]

250 200
200
150
150
100
100 H15

50 50
L15
0 H1 H8 0 L1
L8
400 500 600 700 800 900 300 400 500 600 700 800 900
Air flow rate [m3/h] Air flow rate [m3/h]

Legend
Notes L1= Low speed lower limit
L8= Low speed factory setting
1. The fan curves are determined with ·1/3· of the ESP on the outdoor side L15= Low speed upper limit
(·EA & OA·), and ·2/3· of the ESP on the indoor side (·RA & SA·). H1= High speed lower limit
EA = Exhaust air Ultra-high speed
H8= High speed factory setting
OA = Outdoor air H15= High speed upper limit
RA= Room air High speed
UH1= Ultra-high speed lower limit
SA = Supply air UH8= Ultra-high speed factory setting
2. Measured according to ·JIS B 8628 - 2003· Low speed
UH15= Ultra-high speed upper limit
3D112837

VAM1000J
300 Ultra-high speed
150m
UH15
350
250
UH8 120m 300
200 H15
External static
pressure [Pa]

250
UH1 90m
H8
External static
pressure [Pa]

150 200
L15
H1 150
100 UH15
L8 100
50 30m 50 UH8
L1 Ø250
Duct lenght 0 UH1
0
400 500 600 700 800 900 1000 1100 600 700 800 900 1000 1100
Air flow rate [m3/h] Air flow rate [m3/h]

High speed High speed


300 250
250
External static pressure [Pa]

External static pressure [Pa]

200
200
150
150
100
100
H15
50
50 L15
0 L1
0 H1 H8
400 500 600 700 L8 800 900
500 600 700 800 900 1000
Air flow rate [m3/h] Air flow rate [m3/h]

Notes Legend
1.The fan curves are determined with ·1/3· of the ESP on the outdoor side (·EA & OA·), L1 = Low speed lower limit
and ·2/3· of the ESP on the indoor side (·RA & SA). LB = Low speed factory setting
L15 = Low speed upper limit
EA= Exhaust air Ultra-high speed H1 = High speed lower limit
OA = Outdoor air High speed H8 = High speed factory setting
RA= Room air Low speed H15 = High speed upper limit
SA= Supply air UH1 = Ultra-high speed lower limit
UH8 = Ultra-high speed factory setting
2. Measured according to ·JIS B 8628 - 2003· UH15 = Ultra-high speed upper limit
3D112832
70
VIEW ALL VAM-J TECHNICAL VIEW ALL VAM-FC TECHNICAL
DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM1500J
VAM1500J
300

UH15
External static pressure [Pa]

250
Ultra-high speed
350
H15
200 180m

External static pressure [Pa]


UH8 300
150m
150 250
H8 L15 120m
UH1 200
100 90m
UH15
H1 150
L8 60m
50
100
30m
L1 2xØ250
0 Duct length 50 UH8
700 900 1100 1300 1500 1700
0
UH1
Air flow rate [m³/h] 700 900 1100 1300 1500 1700

Air flow rate [m³/h]


High speed Low speed
300 250

External static pressure [Pa]


External static pressure [Pa]

250
200

200
150
150

100
100 H15

50 L15
50

H1 H8
0 0
L1 L8
700 900 1100 1300 1500 1700 700 900 1100 1300 1500
Air flow rate [m³/h]
Air flow rate [m³/h]

Legend
L1 = Low speed lower limit
Notes
1. The fan curves are determined with ·1/3· of the ESP on the outdoor side (·EA & OA·),and ·2/3· of the ESP on the indoor side (·RA & SA·). L8 = Low speed factory setting
EA = Exhaust air L15 = Low speed upper limit
OA = Outdoor air H1 = High speed lower limit
RA = Room air H8 = High speed factory setting
SA = Supply air H15 = High speed upper limit
2 .Measured according to ·JIS B 8628 - 2003· Ultra-high speed UH1 = Ultra-high speed lower limit
High speed
Low speed UH8 = Ultra-high speed factory setting
UH15 = Ultra-high speed upper limit 3D112838

VAM2000J
VAM2000J
300
150m
UH15
250
120m
Ultra-high speed
350
UH8
External static pressure [Pa]
External static pressure [Pa]

H15
200 300
UH1 90m
250
H8
150
L15 200
H1 60m
150
100
L8 UH15
100
30m
50
L1 50 UH8
2xØ250
Duct length 0 UH1
0 1200 1400 1600 1800 2000 2200
800 1000 1200 1400 1600 1800 2000 2200
Air flow rate [m³/h] Air flow rate [m³/h]
High speed Low speed
300 250
External static pressure [Pa]
External static pressure [Pa]

250
200

200
150

150
100
100
H15
50
50
L15
H1 H8 L1
0 0
L8
1000 1200 1400 1600 1800 2000 800 1000 1200 1400 1600 1800

Air flow rate [m³/h] Air flow rate [m³/h]

Notes
Legend
L1 = Low speed lower limit
1. The fan curves aredetermined with ·1/3· of the ESP on the outdoor side (·EA & OA·), and ·2/3· of the ESP on the indoor side (·RA &SA·). L8 = Low speed factory setting
EA=Exhaust air L15 = Low speed upper limit
OA=Outdoor air
TECHNICAL DRAWINGS

H1 = High speed lower limit


RA=Room air
H8 = High speed factory setting
SA=Supply air
H15 = High speed upper limit
2. Measured according to ·JIS B 8628 - 2003·
UH1 = Ultra-high speed lower limit
Ultra-high speed UH8 = Ultra-high speed factory setting
UH15 = Ultra-high speed upper limit
High speed
Low speed
3D112839

71
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VKM50GB
VKM50GB

Air discharge grille


(locally procured)
Air suction grille
(locally procured)
Heat insulator
(locally procured)

EA Heat insulated
(Exhaust air to outdoors) Branch duct (locally procured)
(locally procured)
Round shape hood
(locally procured)
OA
(Fresh air to outdoors)
Control box

More than 600


Flexible duct Air discharge grille
Inspection Inspection (locally procured) (locally procured)
Maintenance space for the heat exchanger hatch hatch
elements the air filters and fans

360 (in case of □ 450 inspection hatch)


140 (in case of □ 600 inspection hatch)

Refrigerant piping (Gas pipe)


(Ø 12.7 flare connection)
A gradient of
more than 1/30 Refrigerant piping (Liquid pipe)
(Ø 6.4 flare connection)
Ø 200
Nominal diameter
(locally procured)

OA
(Fresh air to outdoors)
EA
(Exhaust air to outdoors)
Suspention bolt
Sloping downwards at (locally procured) SA
Inspection hatch RA
a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)

NOTES
1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easily be
inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation.(Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
5. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
6. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
7. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
8. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up,
or the air filter is very dirty.
3D083014

72
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VKM50GBM
VKM50GBM

Air discharge grille


(locally procured)
Air suction grille
(locally procured)
Heat insulator
(locally procured)

Heat insulated
EA (locally procured)
(Exhaust air to outdoors) Branch duct
Round shape hood (locally procured)
(locally procured)
OA
(Fresh air to outdoors)
Control box

More than 600


Flexible duct Air discharge grille
Inspection Inspection (locally procured) (locally procured)
Maintenance space for the heat exchanger hatch hatch
elements the air filters, fans and humidifier

360 (in case of □ 450 inspection hatch)


140 (in case of □ 600 inspection hatch)
Water supply shut-off valve
Cistern tank (locally procured)
Drain valve
(locally procured) Refrigerant piping (Gas pipe)
A gradient of (Ø 12.7 flare connection)
more than 1/30 Strainer Refrigerant piping (Liquid pipe)
(locally procured) (Ø 6.4 flare connection)
Ø 200
Nominal diameter
(locally procured)

OA
(Fresh air to outdoors)
EA
(Exhaust air to outdoors)
□ 450 - 600 Suspention bolt
(locally procured)
Sloping downwards at Inspection hatch RA SA
a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)

NOTES
1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easily be
inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Use city water or clean water.
Include water supply piping with strainer, a water supply shut-off valve, and a drain valve (both locally procured) somewhere along the water supply piping that can be reached from the
inspection.
5. It is impossible to connect the water supply piping directly to public piping. Use a cistern tank (of the approved type), if you need to get your water supply from public piping.
6. Make sure the supply water 0.02MPa to 0.49MPa (0.2 kg/cm2 to 5 kg/cm2 )
7. Make sure the supply water is between 5°C and 40°C in temperature.
8. Insulate the water supply piping to prevent condensation from forming.
9. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
10. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
11. Install in a location where the air around the unit or taken into the humidifier will not drop below 0°C.
12. Do not use a bent cap or a round hoodas the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
13. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
14. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the
air filter is very dirty.
15. Feed clean water. If the supply water is hard water, use a water softener because of short life.
Life of humidifying element is about 3 years (4,000 hours), under the supply water conditions of hardness: 150 mg/L. (Life of humidifying element is about 1 years (1500 hours), under the
supply water conditions of hardness: 400 mg/L.)
TECHNICAL DRAWINGS

3D083011

73
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VKM80GB
VKM80GB

Air suction grille Air discharge grille


Heat insulator (locally procured) (locally procured)
(locally procured)

Heat insulated
EA Branch duct (locally procured)
(Exhaust air to outdoors)
(locally procured)
Round shape hood
(locally procured)
OA Silencer
(Fresh air to outdoors)
(locally procured)
Control box Flexible duct Air discharge grille

More than 600


(locally procured) (locally procured)
Inspection Inspection
Maintenance space for the heat exchanger hatch hatch
elements the air filters and fans

360 (in case of □ 450 inspection hatch)


140 (in case of □ 600 inspection hatch)

Refrigerant piping (Gas pipe)


A gradient of (Ø 12.7 flare connection)
Ø 250 more than 1/30 Refrigerant piping (Liquid pipe)
Nominal diameter (Ø 6.4 flare connection)
(locally procured)

OA
(Fresh air to outdoors)
EA
(Exhaust air to outdoors)
□ 450 - 600 Suspention bolt
(locally procured)
Sloping downwards at Inspection hatch RA SA
a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)

NOTES
1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easily be
inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
5. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
6. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
7. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
8. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the
air filter is very dirty.

3D083015

74
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VKM80GBM
VKM80GBM

Air suction grille Air discharge grille


Heat insulator (locally procured) (locally procured)
(locally procured)

Heat insulated
EA Branch duct (locally procured)
(Exhaust air to outdoors)
(locally procured)
Round shape hood
(locally procured)
OA
(Fresh air to outdoors) Silencer
(locally procured)
Control box Flexible duct Air discharge grille

More than 600


(locally procured) (locally procured)
Inspection Inspection
Maintenance space for the heat exchanger hatch hatch
elements the air filters, fans and humidifier

360 (in case of □ 450 inspection hatch)


140 (in case of □ 600 inspection hatch)
Water supply shut-off valve
Cistern tank (locally procured)
Drain valve
(locally procured) Refrigerant piping (Gas pipe)
(Ø 12.7 flare connection)
A gradient of
more than 1/30 Strainer Refrigerant piping (Liquid pipe)
(locally procured) (Ø 6.4 flare connection)
Ø 250
Nominal diameter
(locally procured)

OA
(Fresh air to outdoors)
EA
(Exhaust air to outdoors) Suspention bolt
□ 450 - 600 (locally procured)
Sloping downwards at Inspection hatch RA SA
a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)

NOTES
1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easilybe
inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Use city water or clean water.
Include water supply piping with strainer, a water supply shut-off valve, and a drain valve (both locally procured) somewhere along the water supply piping that can be reached from the
inspection
5. It is impossible to connect the water supply piping directly to public piping. Use a cistern tank (of the approved type), if you need to get your water supply from public piping.
6. Make sure the supply water 0.02MPa to 0.49MPa (0.2 kg/cm2 to 5 kg/cm2 )
7. Make sure the supply water is between 5°C and 40°C in temperature.
8. Insulate the water supply piping to prevent condensation from forming.
9. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
10. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
11. Install in a location where the air around the unit or taken into the umidifier will not drop below 0°C.
12. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
13. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
14. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case,where humidity is 80% more, or the exit of drain socket is choked up, or the
air filter is very dirty.
15. Feed clean water. If the supply water is hard water, use a water softener because of short life.
Life of humidifying element is about 3 years (4,000 hours), under the supply water conditions of hardness: 150 mg/L. (Life of humidifying element is about 1 years (1500 hours), under the
supply water conditions of hardness: 400 mg/L.)
TECHNICAL DRAWINGS

3D083012

75
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VKM100GB
VKM100GB

Air suction grille Air discharge grille


Heat insulator (locally procured) (locally procured)
(locally procured)

Heat insulated
EA Branch duct (locally procured)
(Exhaust air to outdoors)
(locally procured)
Round shape hood
(locally procured)
OA Silencer
(Fresh air to outdoors)
(locally procured)
Control box Flexible duct Air discharge grille

More than 600


(locally procured) (locally procured)
Inspection Inspection
Maintenance space for the heat exchanger hatch hatch
elements the air filters and fans

360 (in case of □ 450 inspection hatch)


140 (in case of □ 600 inspection hatch)

Refrigerant piping (Gas pipe)


A gradient of (Ø 12.7 flare connection)
more than 1/30 Refrigerant piping (Liquid pipe)
(Ø 6.4 flare connection)
Ø 250
Nominal diameter
(locally procured)

OA
(Fresh air to outdoors)
EA
(Exhaust air to outdoors)
□ 450 - 600 Suspention bolt
Sloping downwards at Inspection hatch (locally procured) RA SA
a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)

NOTES

1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easily be
inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
5. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
6. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
7. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
8. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the
air filter is very dirty.

3D083016

76
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VKM100GBM
VKM100GBM

Air suction grille Air discharge grille


Heat insulator (locally procured) (locally procured)
(locally procured)

Heat insulator
EA Branch duct (locally procured)
(Exhaust air to outdoors)
(locally procured)
Round shape hood
(Locally procured)
OA Silencer
(Fresh air from outdoors)
(locally procured)
Control box Flexible duct Air discharge grille

More than 600


(locally procured) (locally procured)
Inspection Inspection
Maintenance space for the heat exchanger hatch hatch
elements the air fans and

360 (in case of □ 450 inspection hatch)


140 (in case of □ 600 inspection hatch)
Water supply shut-off valve
Cistern tank (locally procured) Drain valve
(locally procured) Refrigerant piping (Gas pipe)
A gradient of (Ø 12.7 connection)
more than 1/30 Strainer Refrigerant piping (Liquid pipe)
(accessory) (Ø 6.4 connection)
Ø 250
Nominal diameter
(locally procured)

OA
(Fresh air from outdoors)
EA
(Exhaust air to outdoors) Suspension bolt
□ 450 • 600
Sloping downwards at a Inspection hatch (locally procured) RA SA
gradient of the 1/100 (Return air from room) (Return air to room)
(locally procured)

NOTES

1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters, heat exchange elements, fans and humidifier
elements can easily be inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water. Also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Use city water or clean water.
Include water supply piping with strainer, a water supply shut-off valve, and a drain valve (both locally procured) somewhere along the water supply piping that can be reached from the
inspection.
5. It is impossible to connect the water supply piping directly to public piping. Use a cistern tank (of the approved type), if you need to get your water supply from public piping.
6. Make sure the supply water 0.02MPa to 0.49MPa (0.2 kg/cm2 to 5 kg/cm2 )
7. Make sure the supply water is between 5°C and 40°C in temperature.
8. Insulate the water supply piping to prevent condensation from forming.
9. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
10. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
11. Install in a location where the air around the unit or taken into the humidifier will not drop below 0°C.
12. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
13. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
14. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the
air filter is very dirty.
15. Feed clean water. If the supply water is hard water, use a water softener because of short life.
Life of humidifying element is about 3 years (4,000 hours), under the supply water conditions of hardness: 150 mg/L. (Life of humidifying element is about 1 years (1500 hours), under the
supply water conditions of hardness: 400 mg/L.)
TECHNICAL DRAWINGS

3D083013

77
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VKM50GB
VKM50GB
–––––– 50Hz, 220V-240V Exchange
efficiency
Operating air flow rate range (%)

Temp
eratu
re ex
chan
ge eff
Enth icienc Operating air flow rate range Operating air flow rate range Operating air flow rate range
alpy y
exch
ange
efficie
Enth ncy (
alpy heati
exch ng)
ange
effic ø200
ienc
y (co
oling Pipe
)
length
External static pressure (Pa)

Ultra High

External static pressure (Pa)

High

Low

Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h]
Low High Ultra High

[Reading of Performance Characteristics]

1) For example: 19(29)- -07 2) Rated point: ●


Mode no. : 19(29) 3) The characteristic of each tap becomes a setup of the
First code: (Supply ┌ 2 Exhaust ┌ 3 )
Second code no. : 07
┘ ┘ characteristic of the same code number.
3D082904

VKM50GBM
VKM50GBM
–––––– 50Hz, 220V-240V Exchange
efficiency
Operating air flow rate range (%)

Temp VKM50GBM
erature
excha
nge e
Enth fficien
alpy cy
exch
ange
effic
ienc
Enth y (he
alpy
exch
ating
) Operating air flow rate range Operating air flow rate range Operating air flow rate range
ange
efficie ø200
ncy (
cooli Pipe
ng)
External static pressure (Pa)

length
External static pressure (Pa)

Ultra High

High

Low

Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h]
Low High Ultra High

[Reading of Performance Characteristics]

1) For example: 19(29)- -07


Mode no. : 19(29) 2) Rated point: ●
First code: (Supply ┌ 2 Exhaust ┌ 3 ) 3) The characteristic of each tap becomes a setup of the
Second code no. : 07
┘ ┘ characteristic of the same code number. 3D082901

78
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VKM80GB
VKM80GB
–––––– 50Hz, 220V-240V Exchange
efficiency
Operating air flow rate range (%) Operating air flow rate range Operating air flow rate range Operating air flow rate range

Tem
pera
ture
exch
ange
Enth efficie
alpy ncy
exch
ange
effic
Enth ienc
alpy y (he
exch ating

External static pressure (Pa)


ange )
External static pressure (Pa)

effic
ienc
y (co
oling
)

Ultra High

High ø250
Pipe
length

Low

Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h]
Low High Ultra High

[Reading of Performance Characteristics]

1) For example: 19(29)- -07


Mode no. : 19(29) 2) Rated point: ●
First code: (Supply ┌ 2 Exhaust ┌ 3 ) 3) The characteristic of each tap becomes a setup of the
Second code no. : 07
┘ ┘ characteristic of the same code number. 3D082905

VKM80GBM
VKM80GBM
–––––– 50Hz, 220V-240V
Exchange
Operating air flow efficiency
Operating air flow rate range Operating air flow rate range Operating air flow rate range
rate range (%)

VKM80GBM

Tempe
rature e
xchang
Enth e efficie
alpy ncy
exch
ang
e ef
Enth ficie
External static pressure (Pa)

alpy ncy
exch (hea
External static pressure (Pa)

ange ting)
effic
ienc
y (co
oling
)

Ultra High ø250


Pipe
length
High

Low

Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h]
Low High Ultra High

[Reading of Performance Characteristics]


TECHNICAL DRAWINGS

1) For example: 19(29)- -07


Mode no. : 19(29) 2) Rated point: ●
First code: (Supply ┌ 2 Exhaust ┌ 3 ) 3) The characteristic of each tap becomes a setup of the
Second code no. : 07
┘ ┘ characteristic of the same code number. 3D082902

79
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VKM100GB
VKM100GB
–––––– 50Hz, 220V-240V
Exchange
efficiency
Operating air flow rate range (%)

Operating air flow rate range Operating air flow rate range Operating air flow rate range
Tem
pera
Ent ture
halp exc
y ex han
cha ge e
nge fficie
effic ncy
ienc
Ent y (h
eatin
External static pressure (Pa)

hal g)
py
exc
han
ge
effi

External static pressure (Pa)


cien ø250
cy (
coo Pipe
ling
)
length
Ultra High

High

Low

Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h]


Air flow rate[m³/h]
Low High Ultra High

[Reading of Performance Characteristics]

1) For example: 19(29)- -07


Mode no. : 19(29) 2) Rated point: ●
First code: (Supply ┌ 2 Exhaust ┌ 3 ) 3) The characteristic of each tap becomes a setup of the 3D082906
Second code no. : 07
┘ ┘ characteristic of the same code number.

VKM100GBM
VKM100GBM
–––––– 50Hz, 220V-240V Exchange efficiency
(%)

Operating air flow rate


range

Operating air flow rate range Operating air flow rate range Operating air flow rate range
VKM100GBM
Tem
pera
ture
En exc
tha han
lpy ge e
exc fficie
han ncy
External static pressure (Pa)

ge
effi
En cie
tha ncy
lpy (he
exc atin
han
External static pressure (Pa)

g)
ge
effi
cie
ncy ø200
(co
olin Pipe
g)
length
Ultra High

High

Low

Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h]
Low High Ultra High

[Reading of Performance Characteristics]

1) For example: 19(29)- -07


Mode no. : 19(29) 2) Rated point: ●
First code: (Supply ┌ 2 Exhaust ┌ 3 ) 3) The characteristic of each tap becomes a setup of the
Second code no. : 07
┘ ┘ characteristic of the same code number. 3D082903

80
Notes

81
TECHNICAL DRAWINGS
Notes

82
83
Daikin Europe N.V.  Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Publisher)

The present publication is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has
compiled the content of this publication to the best of its knowledge. No express
or implied warranty is given for the completeness, accuracy, reliability or fitness
for particular purpose of its content and the products and services presented
ECPEN19-20312/18 therein. Specifications are subject to change without prior notice. Daikin Europe
N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest
sense, arising from or related to the use and/or interpretation of this publication.
All content is copyrighted by Daikin Europe N.V.

Printed on non-chlorinated paper.