Including
new
Modular L
Fresh air for the residential and commercial sector
Heat reclaim ventilation and air handling applications
MODULAR L (SMART)
D-AHU MODULAR R
2
INTRO
Table
of contents
The widest ventilation range on the market 4
Technical drawings 57
3
ARGUE CARDS
5 reasons
why Daikin’s ventilation range
is unique in the market
21°C
4
INTRO
3 High energy efficiency Up to
›› Energy recovery of up to 92%, reducing running costs
›› Free nighttime cooling using fresh outside air 92%
›› Inverter driven centrifugal fans heat recovery
›› ErP compliant
4 Best comfort
›› Wide range of units to control fresh air and humidity
›› Wide range of optional filters to suit the application available up to ePM1 80% (F9)
›› Special paper heat exchanger recovers heat and moisture from outgoing air to
warm up and humidify incoming air to comfortable levels (VAM, VKM)
5 Top reliability
›› Most extensive testing before new units leave the factory
ErP
›› Widest support network and after sales service COMPLIANT
›› All spare parts available in Europe
5
Widest range of DX integrated
ventilation on the market
Ventilation solutions
Our heat recovery units recover sensible heat (Modular L / Modular L Smart) and
latent heat (VAM/VKM), substantially reducing the load on the air conditioning
system up to 40%.
6
INTRO
Five components of indoor air quality
Ventilation
›› Ventilation: Ensures the provision of fresh air
›› Energy recovery: Delivers energy savings by transferring heat and
Energy
moisture between airflows Humidification
recovery
›› Air processing: Delivers the right supply temperature to decrease the
indoor unit load
›› Humidification: Ensures relative indoor humidity levels are respected
›› Filtration: Separates pollen, dust and pollution odours that are harmful Air
to individuals’ health Filtration
processing
150 500 1,000 2,000 2,500 3,000 3,500 15,000 25,000 140,000 [m3/h]
›› Pre-configured sizes
›› Plug & Play pre-configured controls
›› With DX or water coil option
D-AHU MODULAR R
›› Fully customizable
›› Plug & play
›› 4 types of control
›› With DX or water coil option
D-AHU Professional
7
Direct integration into the Sky
Air or VRV control solution
› Saves up to 40% in running costs
› Unified control point for the complete air
conditioning and ventilation installation
8
Energy /
Heat Reclaim Ventilation
ERV/HRV BENEFITS
Ventilation Interlocked with
air conditioning system
9
Benefits of
Daikin ERV/HRV systems
10
1 Market leading controls & connectivity
ERV/HRV BENEFITS
Interlock of the ventilation operation with functions. By incorporating a variety of centralised
the air conditioner operation greatly simplifies control equipments, the user can build a large,
overall system control. The same remote controller high grade centralised control system.
centralises air conditioning and ventilation
INTERLOCKING
BRC1H519W/S/K
›› Sleek and elegant design
›› Intuitive touch button control
›› 3 color versions
›› Advanced settings and monitoring can
be easily done via your smartphone Advanced user settings Field settings
›› Flat back for easy wall installation
›› Compact to fit standard size socket boxes
One
Plug & Play - integrated ventilation Stop
Shop
11
2 Easy and flexible installation
Why?
After installation the real ducting will frequently differ from the ini-
tially calculated air flow resistance the real air flow may be much
lower or higher than designed.
Automatic Airflow Adjustment function will adapt the unit’s fan Duct resistance
matic adjustment )
curves
speed to any ducting automatically (45 fan curves are a vailable on
every model (ALB/VAM)), making installation much faster.
± /min)
0° -5°
with optional
CDB -10°
preheater
-10° CDB
preheater
preheater
-15°
optional
optional
with
with
CDB
-20°
… … …
12
Flexible installation
280mm
Slim Design
ERV/HRV BENEFITS
the HRV unit enables it to be mounted in narrow
ceiling cavities and irregularly shaped spaces
FLEXIBILITY ON
Indoor
unit
ALB-RBS/LBS VAM/VKM
Wired remote control Outdoor unit
Example when HRV ESP is not high enough or field situation differs from calculation
HRV HRV
Comfort Comfort Discomfort Comfort Comfort Comfort
13
3 High efficiency
92%
offering high energy efficiency.
of wasted heat
ALB-RBS/LBS
EA RA EA RA
Automatic
changeover
OA SA OA SA
EA: Exhaust air RA: Return air (from room) OA: Outdoor air SA: Supply air (to room)
14
Heat reclaim ventilation
ERV/HRV BENEFITS
equipment that increases room temperature,
The VAM and Modular L Smart can also perform nighttime free cooling in stand alone operation. The set temperature is a field setting at installation.
Set T°
30°C Indoor temperature
Outdoor temperature
20°C
… 5 PM 9 AM …
Increase in air
volume and
better comfort
When many people are in the room,
compared to fixed
more fresh air is brought in to maintain
ventilation rate
comfortable CO2 levels. When fewer
people are in the room, energy is saved by
bringing in less fresh air.
7 8 9 10 11 12 13 14 15 16 17 18 19 hour
15
4 Best Comfort
• High quality indoor air
• Whisper quiet
A higher air supply than air exhaust maintains proper A higher exhaust air than air supply decreases room
room pressure to prevent back-flow of toilet/kitchen pressure to prevent the leaking of odours or floating
odours or moisture inflow. bacteria into other rooms.
70%
30% Sick room
Portion of
Air supply 70% 100%
exhaust
100% operation
Preventing that toilet odours flow to the office No bacteria can flow from the sick room to the hall way
16
Modular L Smart
Premium Efficiency Heat Recovery Unit
NEW Ventilation
MODULAR L SMART
Energy
Humidification
recovery
Air
Filtration
processing
ALB-RBS/LBS
›› Connects Plug&Play into the Sky Air and VRV ›› Premium quality counter flow plate
control network heat exchanger
›› Easy installation and commissioning ›› Up to 92% of the thermal energy recovered
›› Internal pre-filter stage (up to ePM1 50% (F7) ›› High grade aluminum allowing optimum
+ ePM1 80% (F9)) making the unit reach highest corrosion protection
indoor air quality requirements.
›› Wide air flow coverage from 150m3/h
to 3,450m3/h
›› Exceeding ERP 2018 requirements
›› Best choice when compactness is needed
(only 280 mm height up to 550 m3/h)
›› 50 mm double skin panel (120 kg/m3) for a
maximum sound and thermal insulation
EC centrifugal fan
17
Premium quality to meet most
sophisticated needs
Heat exchanger
› Premium quality counterflow
plate heat exchanger
› Up to 92% of the thermal energy
recovered
› High grade aluminium that allows
best corrosion protection
› Completely joint sealing
› No screws or rivets in any part
Filters
› Easy replaceable compact filters with large
surface area, which can be removed from
bottom access
› Up to ePM1 50% (F7) + ePM1 80% (F9)
filtration efficiency
› No tools are needed to change the filters
› Fresh air filters* (ePM1 50% (F7) efficiency
as standard)
› Return filters* (ePM10 75% (M5) efficiency
as standard)
Supply/Return fan
› Fan/motor combination with very
low noise level
› Reduced energy consumption
› Inverter driven with IE4 motor efficiency
› Infinitely variable speed
› Ultra-efficient blade profiling
› Maintenance-free ball bearings
› No screws or rivets in any part
18
MODULAR L SMART
Rectangular duct flange
The standard dimensions are:
› 250x150 (Size 2)
› 400x200 (Size 3)
› 500x300 (Size 4/5)
› 700x400 (Size 6/7)
Bypass damper
Unit structure
› 100% automatic bypass damper with
› External pre – painted metal sheet proportional opening for antifreeze and free
› Internal Aluzinc cooling operation
› 50 mm Double skin panel thickness
› Mineral wool insulated
› Great sound absorption and low noise Fully integratable in the DIII
› Hinged or fully removable bottom doors make the
unit easy accessible for service and maintenance network (Sky Air and VRV)
› Unit is accessible from bottom panels
› Best choice when compactness is needed (only
280 mm height for up to 550 m3/h of air flow)
19
Technical details
Control logic
› Air quality analysis with the capability of monitoring and control of the actual level of CO2 through optional sensor (accessory)
› Full automatic bypass to manage free cooling
› Filter alarm in accordance with the EU Reg 1253
› DIII-net integration through Daikin building air conditioning control systems (D-BACS)
› BMS integration through dedicated interfaces (Modbus, BACnet)
Modular L Smart is available in 6 sizes covering a wide range of applications such as hotels, offices, schools and light commercial
buildings
Size 3000
2300 Size 7
1500 Size 6
1200 Size 5
600 Size 4
300 Size 3
Size 2
20
MODULAR L SMART
Return Air Fresh Air Fresh Air Return Air
Technical details
21
ERV
energy reclaim ventilation
Heat reclaim ventilation, air processing and humidification
Ventilation Ventilation
Energy Energy
Humidification Humidification
recovery recovery
Air Air
Filtration Filtration
processing processing
›› Energy saving ventilation via enthalpy recovery of ›› Plug & Play - integrated ventilation
both heat and humidity ›› Flexible installation
›› Reduce the load on the air conditioning system by ›› Wide range of units
up to 40% ›› High static pressure
›› Nighttime free cooling ›› Wide operation range
›› Prevent energy losses from over-ventilation with ›› Connection to field-supplied booster fan
CO2 sensor increases flexibility even more (VAM-FC/J only)
›› No drain needed (VAM-FC/J only)
22
Energy saving ventilation via enthalpy recovery
of both heat and humidity
Daikin’s ERV solutions prevent energy being wasted Specially developed heat exchange element
by recovering up to 85% waste heat from the
Recovers up to outgoing air instead of simply expelling the heat, The heat exchange element rapidly recovers heat
85%
offering high energy efficiency. contained in latent heat (vapour).
of waste heat
Outdoor Indoor
SA
Operation of the high 30.6°C 27.4°C Temperature SA
efficiency paper. 62% RH 63% RH and humidity
VAM/VKM
are exhanged
Cross flow of air to
between the
exchange heat and RA
32°C RA layers
moisture.
70% RH 26°C
50% RH
Integrally-formed liner
or vertically
False ceiling Access
The VAM models do not require a drain, giving hatch
greater flexibility for the installation of the units.
Access
hatch
Maintenance cover
23
Creating a high quality environment
Maintain a comfortable indoor environment without fluctuations in room temperature.
In heating In cooling
Heat recovery Heat recovery
+ +
Heating Cooling 100 80
+ 100 80
60
Humidifying 60
Outdoor air
temperature
Effect of full heat exchange in summer
Effect of cooling
1
40
40 2
Effect of 20
Indoor temperature during heating humidification
3 20
2
Relative humidity (%)
-5 0 5 10 15 20 25 30 35 40 -5 0 5 10 15 20 25 30 35 40
In heating we bring in cold outdoor fresh air and want to avoid cold draught In cooling we bring in hot outdoor fresh air and want to prevent additional load on
and dry air. the air conditioning system and too hot indoor temperatures.
1. Cold outside air is crossed with hot inside air. 1. Hot outside air is crossed with cold inside air.
In the example the incoming air is heated up from 0 to 16°CDB while keeping In the example the incoming air is cooled down from 34 to 27°CDB while keeping
the same relative humidity. This is the effect of the heat and moisture exchange. the same relative humidity. This is the effect of the heat and moisture exchange.
2. The DX coil further cools down the air to prevent hot indoor temperatures and reduce
2. The DX coil further heats up the air to prevent cold draught. In the example the
the load on the air conditioning system.
incoming air is further heated from 16 to 34°CDB. Because the air is heated up the
relative humidity decreases. In the example the incoming air is further cooled down from 27 to 20°CDB.
3. To counter negative effects of dry air the air passes the humidifier which adds
moisture in case needed. 3. No humidification is needed in cooling as the air is not dried out
In the example the relative humidity rises from 22 to a comfortable 42%.
The result is incoming fresh air with the same humidity and slightly higher
The result is incoming fresh air with a slightly lower temperature for perfect comfort.
temperature for perfect comfort.
24
Humidification
VAM/VKM
Heat Exchanger
Exhaust Fan Damper Motor DX coil (Direct expansion coil)
Elements
EA Damper
(Exhaust air to outdoors)
OA
(Fresh air from outdoors)
RA
(Return air from room)
1
VKM-GM example
25
VAM-FC/VAM-J
New diamond
Energy reclaim ventilation Return air
shape heat
Supply air exchanger!
Ventilation with heat recovery as standard
Ventilation VAM/VAM 150FC 250FC 350J 500J 650J 800J 1000J 1500J 2000J
Power input - 50Hz Heat Nom. Ultra high/High/Low kW 0.132/0.111/ 0.161/0.079/ 0.097 /0.070 / 0.164 /0.113 / 0.247 /0.173 / 0.303 /0.212 / 0.416 /0.307 / 0.548 /0.384 / 0.833 /0.614 /
exchange
mode 0.058 0.064 0.039 0.054 0.081 0.103 0.137 0.191 0.273
Bypass mode Nom. Ultra high/High/Low kW 0.132/0.111/ 0.161/0.079/ 0.085 /0.061 / 0.148 /0.100 / 0.195 /0.131 / 0.289 /0.194 / 0.417 /0.300 / 0.525 /0.350 / 0.835 /0.600 /
0.058 0.064 0.031 0.045 0.059 0.086 0.119 0.156 0.239
Temperature Ultra high/High/Low % 77.0 (1) / 72.0 (2)/ 74.9 (1) / 69.5 (2)/
85.1 /86.7 / 80.0 /82.5 / 84.3 /86.4 / 82.5 /84.2 / 79.6 /81.8 / 83.2 /84.8 / 79.6 /81.8 /
exchange 78.3 (1) / 72.3 (2)/ 76.0 (1) / 70.0 (2)/
90.1 87.6 90.5 87.7 86.1 88.1 86.1
efficiency - 50Hz 82.8 (1) / 73.2 (2) 80.1 (1) / 72.0 (2)
Enthalpy exchange Cooling Ultra high/High/Low % 60.3 (1)/61.9 (1)/ 60.3 (1)/61.2 (1)/ 65.2 /67.9/ 59.2 /61.8 / 59.2 /63.8 / 67.7 /70.7 / 62.6 /66.4 / 68.9 /71.8 / 62.6 /66.4 /
efficiency - 50Hz 67.3 (1) 64.5 (1) 74.6 69.5 73.1 76.8 74.0 77.5 74.0
Heating Ultra high/High/Low % 66.6 (1)/67.9 (1)/ 66.6 (1)/67.4 (1)/ 75.5 /77.6 / 69.0 /72.2 / 73.1 /76.3 / 72.8 /75.3 / 68.6 /71.7 / 73.8 /76.1 / 68.6 /71.7 /
72.4 (1) 70.7 (1) 82.0 78.7 82.7 80.2 77.9 80.8 77.9
Operation mode Heat exchange mode, bypass mode, fresh-up mode
Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange
Heat exchange element Specially processed non-flammable paper
Dimensions Unit HeightxWidthxDepth mm 285x776x525 301x1,113x886 368x1,354x920 368x1,354x1,172 731x1,354x1,172
Weight Unit kg 24.0 46.5 61.5 79.0 157
Casing Material Galvanised steel plate
Fan Air flow Heat Ultra high/High/ m³/h 350 (1)/ 500 (1)/ 650 (1)/ 800 (1)/ 1,000 (1)/ 1,500 (1)/ 2,000 (1)/
exchange Low 150 /140 /105 250 /230 /155 300 (1)/ 425 (1)/ 550 (1)/ 680 (1)/ 850 (1)/ 1,275 (1)/ 1,700 (1)/
rate - mode 200 (1) 275 (1) 350 (1) 440 (1) 550 (1) 825 (1) 1,100 (1)
50Hz Bypass mode Ultra high/High/ m³/h 350 (1)/ 500 (1)/ 650 (1)/ 800 (1)/ 1,000 (1)/ 1,500 (1)/ 2,000 (1)/
Low 150 /140 /105 250 /230 /155 300 (1)/ 425 (1)/ 550 (1)/ 680 (1)/ 850 (1)/ 1,275 (1)/ 1,700 (1)/
200 (1) 275 (1) 350 (1) 440 (1) 550 (1) 825 (1) 1,100 (1)
External static Ultra high/High/Low Pa 90 /87/40 70 /63/25 90 (1)/70.0 /50.0 (1)
pressure - 50Hz
Air filter Type Multidirectional fibrous fleeces Multidirectional fibrous fleeces (G3)
Sound pressure Heat Ultra high/High/Low dBA 27.0 /26.0 28.0 /26.0 34.5 (1)/ 37.5 (1)/ 39.0 (1)/ 39.0 (1)/ 42.0 (1)/ 42.0 (1)/ 45.0 (1)/
exchange 32.0 (1)/ 35.0 (1)/ 36.0 (1)/ 36.0 (1)/ 38.5 (1)/ 39.0 (1)/ 41.5 (1)/
level - 50Hz mode /20.5 /21.0 29.0 (1) 30.5 (1) 31.0 (1) 30.5 (1) 32.5 (1) 33.5 (1) 36.0 (1)
Bypass Ultra high/High/Low dBA 27.0 /26.5 28.0 /27.0 34.5 (1)/ 38.0 (1)/ 38.0 (1)/ 40.0 (1)/ 42.5 (1)/ 42.0 (1)/ 45.0 (1)/
/20.5 /21.0 32.0 (1)/ 35.0 (1)/ 34.5 (1)/ 36.5 (1)/ 40.0 (1)/ 39.0 (1)/ 41.0 (1)/
mode 28.0 (1) 29.5 (1) 30.5 (1) 30.5 (1) 32.5 (1) 32.5 (1) 35.0 (1)
Operation range Around unit °CDB - 0°C~40°CDB, 80% RH or less
Connection duct diameter mm 100 150 200 250 2x250
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Current Maximum fuse amps (MFA) A 15.0 16.0
Specific energy Cold climate kWh/(m².a) -56.0 (5) -60.5 (5) -
consumption (SEC) Average climate kWh/(m².a) -22.1 (5) -27.0 (5) -
Warm climate kWh/(m².a) -0.100 (5) -5.30 (5) -
SEC class D / See note 5 B / See note 5 -
Maximum flow rate Flow rate m³/h 130 207 -
at 100 Pa ESP Electric power input W 129 160 -
Sound power level (Lwa) dB 40 43 51 54 58 61 62 65
Annual electricity consumption kWh/a 18.9 (5) 13.6 (5) -
Annual heating Cold climate kWh/a 41.0 (5) 40.6 (5) -
saved Average climate kWh/a 80.2 (5) 79.4 (5) -
Warm climate kWh/a 18.5 (5) 18.4 (5) -
(1)Measured according to JIS B 8628 | (2)Measured at reference flow rate according to EN13141-7 | Measured according to EN308 : 1997 | In accordance with commission regulation (EU) No 1254/2014 | In accordance with commission regulation (EU) No
1253/2014 | At reference flow rate in accordance with commission regulation (EU) No 1254/2014 | Clean the filter when the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit's energy efficiency.
26
VKM-GB/VKM-GBM
VAM/VKM
Ventilation VKM-GB/VKM-GBM 50GB 80GB 100GB 50GBM 80GBM 100GBM
Power input - 50Hz Heat exchange Nom. Ultra high/ kW 0.270/0.230/ 0.330/0.280/ 0.410/0.365/ 0.270/0.230/ 0.330/0.280/ 0.410/0.365/
mode High/Low 0.170 0.192 0.230 0.170 0.192 0.230
Bypass mode Nom. Ultra high/ kW 0.270/0.230/ 0.330/0.280/ 0.410/0.365/ 0.270/0.230/ 0.330/0.280/ 0.410/0.365/
High/Low 0.140 0.192 0.230 0.170 0.192 0.230
Fresh air Cooling kW 4.71 / 1.91 / 3.5 7.46 / 2.96 / 5.6 9.12 / 3.52 / 7.0 4.71 / 1.91 / 3.5 7.46 / 2.96 / 5.6 9.12 / 3.52 / 7.0
conditioning load Heating kW 5.58 / 2.38 / 3.5 8.79 / 3.79 / 5.6 10.69 / 4.39 / 7.0 5.58 / 2.38 / 3.5 8.79 / 3.79 / 5.6 10.69 / 4.39 / 7.0
Temperature Ultra high/High/Low %
exchange efficiency 76/76/77.5 78/78/79 74/74/76.5 76/76/77.5 78/78/79 74/74/76.5
- 50Hz
Enthalpy exchange Cooling Ultra high/High/Low % 64/64/67 66/66/68 62/62/66 64/64/67 66/66/68 62/62/66
efficiency - 50Hz Heating Ultra high/High/Low % 67/67/69 71/71/73 65/65/69 67/67/69 71/71/73 65/65/69
Operation mode Heat exchange mode / Bypass mode / Fresh-up mode
Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange
Heat exchange element Specially processed non-flammable paper
Humidifier System - Natural evaporating type
Dimensions Unit HeightxWidthxDepth mm 387x1,764x832 387x1,764x1,214 387x1,764x832 387x1,764x1,214
Weight Unit kg 94 110 112 100 119 123
Casing Material Galvanised steel plate
Fan-Air flow rate Heat exchange mode Ultra high/High/Low m³/h 500/500/440 750/750/640 950/950/820 500/500/440 750/750/640 950/950/820
- 50Hz Bypass mode Ultra high/High/Low m³/h 500/500/440 750/750/640 950/950/820 500/500/440 750/750/640 950/950/820
Fan-External static Ultra high/High/Low Pa
210/170/140 210/160/110 150/100/70 200/150/120 205/155/105 110/70/60
pressure - 50Hz
Air filter Type Multidirectional fibrous fleeces
Sound pressure Heat exchange mode Ultra high/High/Low dBA 39/37/35 41.5/39/37 41/39/36.5 38/36/34 40/37.5/35.5 40/38/35.5
level - 50Hz Bypass mode Ultra high/High/Low dBA 40/38/35.5 41.5/39/37 41/39/36.5 39/36/34.5 41/38/36 41/39/35.5
Operation range Around unit °CDB 0°C~40°CDB, 80% RH or less
Supply air °CDB -15°C~40°CDB, 80% RH or less
Return air °CDB 0°C~40°CDB, 80% RH or less
On coil temperature Cooling/Max./Heating/Min. °CDB -15/43 -15/43
Refrigerant Control Electronic expansion valve
Type R-410A
GWP 2,087.5
Connection duct diameter mm 200 250 200 250
Piping connections Liquid OD mm 6.35
Gas OD mm 12.7
Water supply mm - 6.4
Drain PT3/4 external thread
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Current Maximum fuse amps (MFA) A 15
27
For small to large commercial spaces Daikin offers
a range of inverter condensing units for use in
conjunction with air handling units. In situations
where Daikin commercial range ventilation units
cannot satisfy the ventilation requirement due to
building constraints (large atriums, banquet halls
etc), air handling units represent the ideal solution.
Air handling units provide large fresh air volumes
(>500 m3/h) and high ESPs enabling the use of
extensive ductwork runs.
28
Daikin
Energy
Humidification
recovery
Air
Filtration
processing
AHU
29
Daikin
air handling units solutions
You will find your match
The unique total solution approach by Daikin helps Thanks to the most complete offer in the market,
businesses to propose better cross-pillar solutions, to Daikin has the solution for all types of commercial
increase their success ratio by providing unmatchable applications requiring fresh air. Daikin provides
product combinations to the end-user and to ventilation solutions based on AHU from 2,500 m3/h
simplify the life of installers by supplying high-quality up to 140,000 m3/h either with natural heat recovery
products coming from the same manufacturer. or more advanced ventilation solutions where a
Contrary to other manufacturers, Daikin does not VRV outdoor unit can be connected to the Daikin
use OEM products in its AHU with DX offer. Many AHU for ultimate climate control. The harmonized
competitors are either offering OEM DX outdoor units control between the VRV outdoor unit and the AHU
or OEM AHU which create additional problems when offer outstanding 24h/7 control of the system when
warranties or faults arise. Having a single interface connected to an iTM.
for your business makes Daikin the right choice.
30
Daikin's
31
Daikin Fresh air package - overview
Daikin heat pumps are renowned for their high while the outdoor air is too cold to be brought
energy efficiency. Integrating the AHU with a heat inside in an unconditioned state. In this case heat
recovery system is even more effective since from the offices is merely transferred to heat up
an office system can frequently be in cooling mode the cold incoming fresh air.
Daikin ERQ and VRV units respond rapidly The system is easy to design and install since
to fluctuations in supply air temperature, resulting no additional water systems such as boilers,
in a steady indoor temperature and resultant high tanks and gas connections etc. are required.
comfort levels for the end user. The ultimate is This also reduces both the total system investment
the VRV range which improves comfort even more and running cost.
by offering continuous heating, also during defrost.
›› Plug & Play connection between VRV/ERQ and the entire D-AHU modular range.
›› Factory fitted and welded control and expansion valve kits.
VRV IV or ERQ
condensing unit
Electronic expansion
valve Control box
(EKEXV) (EKEQ)
32
Daikin Fresh air package - Controls
W control: Off the shelf control of air temperature (discharge Z control: Control of air temperature (suction temperature, room
temperature, suction temperature, room temperature) via any temperature) via Daikin control (no DDC controller needed)
DDC controller, easy to setup Y control: Control of refrigerant (Te/Tc) temperature via Daikin
X control: Precise control of air temperature (discharge temperature, control (no DDC controller needed)
suction temperature, room temperature) requiring
a preprogrammed DDC controller (for special applications)
Air temperature control via DDC controller Precise air temperature control via DDC controller
Room temperature is controlled as a function of the air handling Room temperature is controlled as a function of the air handling
unit suction or discharge air (customer selection). The DDC unit suction or discharge air (customer selection). The DDC
controller is translating the temperature difference between set controller is translating the temperature difference between set
point and air suction temperature (or air discharge temperature point and air suction temperature (or air discharge temperature
or room temperature) into a proportional 0-10V signal which is or room temperature) into a reference voltage (0-10V) which is
transferred to the Daikin control box (EKEQFCBA). This voltage transferred to the Daikin control box (EKEQFCBA). This reference
modulates the capacity requirements of the outdoor unit. voltage will be used as the main input value for the compressor
frequency control.
OR
OR OR
OR
AHU
AHU AHU
AHU
TEXT
EXT
TTR TEXT
EXT
TTR
R R
0-10V Control
Daikin boxbox:
control 0-10V Control
Daikin boxbox:
control
DDC
DDC + DDC
DDC +
EKEQFCBA
EKEQFCBA TE TC EKEQFCBA
EKEQFCBA
TTOA TS TTOA TETC TS
OA OA
S S
- -
TROOM TROOM
ROOM ROOM
AHU
TTEXT
EXT
TTRR
BRC1D*
BRC1D* Control box
BRC1E* TEXT
EXT TRR
BRC1E* EKEQFCBA + BRC1D* Control box
Control box
BRC1H* TTOA TE TC TTS
BRC1D*
BRC1E* EKEQMCBA (VRVIV)
EKEQMCBA (VRV IV) +
OA S BRC1E*
- BRC1H* EKEQDCB (ERQ)
(ERQ) TTOA TE
OA TC TS
-
TTROOM
ROOM
OR
OR
TTROOM
ROOM
TS = Supply air temperature TR = Return air temperature TOA = Outdoor air temperature TROOM = Room air temperature
TEXT = Extraction air temperature TE = Evaporating temperature TC = Condensing temperature
33
Daikin Fresh air package - VRV connections
W, X, Y control for VRV IV heat pump Z control for all VRV outdoor units
Refrigerant piping
F1-F2
P1-P2
34
Daikin Fresh air package - ERQ connections
35
Integration with third party air handling units
Combination table
Control box Expansion valve kit
Mixed connection with
EKEQDCB EKEQFCBA EKEQMCBA EKEXV50 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 EKEXV400 EKEXV500
VRV indoor units
Z control W,X,Y control Z control - - - - - - - - - -
ERQ100 P P - - P P P P - - - - -
1-phase ERQ125 P P - - P P P P P - - - -
ERQ140 P P - - - P P P P - - - -
Not possible
ERQ125 P P - - P P P P P - - - -
3-phase ERQ200 P P - - - - P P P P P - -
ERQ250 P P - - - - - P P P P - -
VRV III - - n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 Mandatory
VRV IV H/P / Possible (not
VRV IV W-series - P (1 -> 3) n2 n2 n2 n2 n2 n2 n2 n2 n2 n2 n2 mandatory)
VRV IV S-series
VRV IV H/R - n1 - n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 Mandatory
VRV IV i-series
• P (pair application): combination depends on the capacity of the air handling unit
• n1 (multi application) - Combination of AHUs and VRV DX indoors (mandatory). To determine the exact quantity please refer to the engineering data book.
• n2 (multi application) - Combination of AHUs and VRV DX indoors (not mandatory). To determine the exact quantity please refer to the engineering data book.
• Control box EKEQFA can be connected to some types of VRV IV outdoor units (with a maximum of 3 boxes per unit). Do not combine EKEQFA control boxes with VRV DX indoor units, RA indoor units or hydroboxes
Capacity table
Cooling Heating
Allowed heat exchanger Allowed heat exchanger Allowed heat exchanger Allowed heat exchanger
EKEXV Class capacity (kW) volume (dm3) EKEXV Class capacity (kW) volume (dm3)
Minimum Standard Maximum Minimum Maximum Minimum Standard Maximum Minimum Maximum
50 5.0 5.6 6.2 1.33 1.65 50 5.6 6.3 7.0 1.33 1.65
63 6.3 7.1 7.8 1.66 2.08 63 7.1 8.0 8.8 1.66 2.08
80 7.9 9.0 9.9 2.09 2.64 80 8.9 10.0 11.1 2.09 2.64
100 10.0 11.2 12.3 2.65 3.30 100 11.2 12.5 13.8 2.65 3.30
125 12.4 14.0 15.4 3.31 4.12 125 13.9 16.0 17.3 3.31 4.12
140 15.5 16.0 17.6 4.13 4.62 140 17.4 18.0 19.8 4.13 4.62
200 17.7 22.4 24.6 4.63 6.60 200 19.9 25.0 27.7 4.63 6.60
250 24.7 28.0 30.8 6.61 8.25 250 27.8 31.5 34.7 6.61 8.25
400 35.4 45.0 49.5 9.26 13.2 400 39.8 50.0 55.0 9.26 13.2
500 49.6 56.0 61.6 13.2 16.5 500 55.1 63.0 69.3 13.2 16.5
Saturated evaporating temperature: 6°C Saturated condensing temperature: 46°C
Air temperature: 27°C DB / 19°C WB Air temperature: 20°C DB
(1) The temperature of the air entering the coil in heating mode can be reduced to -5°CDB. Contact your local dealer for more information. (2) 45% Relative humidity.
The combination of EKEQFCBA and ERQ is in pair application. The EKEQFCBA can be connected to some type of VRV IV outdoor units with a maximum of 3 control boxes. The combination with DX indoor units,
hydroboxes, RA outdoor units, ... is not allowed. Refer to the combination table drawing of the outdoor unit for details.
36
Selection
An AHU with double flow, heat recovery and 100% fresh air is to In this particular case, the control will work with precise air
be installed in Europe where the outdoor sizing temperature is 35 temperature control. Only W or X control allow this. Since the
ºCDB and the target supply air temperature for fresh air is 25 ºCDB. consultant wants to use an “off-the-shelf” DDC module, the
Load calculations point to a required capacity of 45kW. EKEQFCBA box with W control allows easy set-up due to pre-set
By checking on the EKEXV capacity table, for cooling operation, factory values.
40kW falls within the 400 class valve. Since 40kW is not the nominal
capacity, a class adjustment has to be done. 40/45=0,89 and
0,89x400=356. So the capacity class of the expansion valve kit is
356.
For this AHU, a VRV IV heat pump model with continuous heating is
going to be used (RYYQ-T series). For a capacity of 40kW at 35 ºCDB,
an outdoor of 14HP (RYYQ14T) is selected. The capacity class of the
14 HP outdoor unit is 350.
An AHU with double flow, heat recovery and 100% fresh air is to
be installed in Europe where the outdoor sizing temperature is For this system where a AHU is connected with indoor units, it is
35 ºCDB and the target supply air temperature for fresh air is 25 mandatory to use a heat recovery unit. By consulting the engi-
ºCDB. On top of this, for this building, 5 round-flow cassette units neering databook for REYQ-T, the total required capacity of 42,5
FXFQ50A will also be connected to this OU. kW requires a 16HP model REYQ16T. Which will deliver 45kW at the
Load calculations point to a required capacity of 20kW for the AHU design temperature of 35 ºCDB. This unit has a capacity class of 400.
and 22,5 kW for the indoor untis. Total connection ratio of the system is 428/400=107% hence it falls
By checking on the EKEXV capacity table, for cooling operation, within the range 50-110%.
20kW falls within the 200 class valve. Since 22,4 kW is the nominal
capacity, a class adjustment has to be done. 20/22,4=0,89 and Step 3: Control box selection
0,89x200=178. So the capacity class of the expansion valve kit is
178. Total capacity class of the indoor unit system is 178+250=428 In this particular case, the only available control is Z control and the
combination of AHU and VRV DX indoor units requires EKEQMCBA
control box.
37
Air handling application
F1/F2
EKEQFCBA EKEKXV*
Digital signal
to steer EEV Treturn
Only for
commissioning OR
Tsupply
outdoor
38
Air handling application
Pair application layout #2: Example for Y control with EKEQFCBA box
F1/F2
EKEQFCBA EKEKXV*
Digital signal
to steer EEV Treturn
Only for
commissioning
Tsupply
outdoor
39
Air handling application
F1/F2
Mandatory
EKEQMCBA EKEKXV*
Digital signal to steer EEV
OR
ROOM
KRCS01-1B
n control boxes
Input signal from sensors
OR
40
Air handling application
Multi application layout #2: Example for Z control with EKEQMCBA box and VRV indoor units
F1/F2
Mandatory
EKEQMCBA EKEKXV*
Digital signal to steer EEV
OR
ROOM
KRCS01-1B
RULES: Σ EKEXV CC: 0-60% Σ IU CC: 50-110% (2 circuits) and another control
DX
outdoor
41
Options & accessories
Options &
accessories
FILTERS
CONTROLS
42
User-friendly wired remote contoller with premium design
DIRECT INTEGRATION
WITH DAIKIN VENTILATION PRODUCTS
43
Heat Recovery Ventilation - Modular L (Smart)
BRC301B61
• • • • • • •
Individual control systems
DCM601A51
intelligent Touch Controller • • • • • • •
systems
DCS302C51
Central remote control • • • • • • •
DCS301B51
Unified ON/OFF control • • • • • • •
DST301B51
Schedule timer • • • • • • •
DCM601A51
• • • • • • •
Management System
& Standard protocol
Modbus interface
DMS502A51
BACnet Interface • • • • • • •
DMS504B51
LonWorks Interface • • • • • • •
Coarse 55% (G4) ALF02G4A ALF03G4A ALF05G4A ALF07G4A
Rail
Mechanical
accessories
Separate plenum
BRYMA200 BRYMA200 BRYMA200 BRYMA200
CO2 sensor (preliminary) (preliminary) (preliminary) (preliminary)
BRYMA65
Adapter PCB for third party heater BRP4A50 BRP4A50 BRP4A50A (4)
44
Energy reclaim ventilation - VAM Energy reclaim ventilation VKM Air handling unit applications
VAM VAM VAM VAM VAM VAM VKM VKM VKM EKEQ EKEQ EKEQ
500J 650J 800J 1000J 1500J 2000J 50GB (M) 80GB (M) 100GB (M) FCBA (1) DCB (1) MCBA (1)
• • • • • •
• • • • • • • • • • • •
• • • • • • • • • • • •
• • • • • • • • • • • •
• • • • • • • • • • • •
• • • • • • • • • • • •
• • • • • • • • •
• • • • • • • • •
• • • • • • • • •
• • • • • • • • • • • •
• • • • • • • • • • • •
• • • • • • • • •
• • • • • • • • •
KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) BRP4A50A (4) BRP4A50A (4) BRP4A50A (4)
KRP1C4 (5) KRP1C4 (3/5) KRP1C4 (5) KRP1C4 (5) KRP1C4 (3/5) KRP1C4 (3/5) BRP4A50A (4) BRP4A50A (4) BRP4A50A (4)
BRP4A50A (4) BRP4A50A (3/4) BRP4A50A (4) BRP4A50A (4) BRP4A50A (3/4) BRP4A50A (3/4) BRP4A50A (4) BRP4A50A (4) BRP4A50A (4)
KRCS01-1
EKMP65VAM EKMPVAM
45
ALD-HEFB
Electrical heater for Modular L Smart (ALD) 02HEFB 03HEFB 05HEFB 07HEFB
Capacity kW 1,5 3 7,5 15
Connectable Modular L Smart size 02 03 04, 05 06, 07
Supply voltage 230V,1ph 400V,3ph
Output current (maximum) (A) 6,6 13,1 10,9 21,7
15k ohms at -20 °C 16k ohms at -20 °C 17k ohms at -20 °C 18k ohms at -20 °C
Temperature sensor
10k ohms at +10 °C 10k ohms at +10 °C 10k ohms at +10 °C 10k ohms at +10 °C
46
VH
47
We’re here to help you!
Online and offline
http://literature.daikinpromoshop.eu
Benefits
We care icons
Seasonal efficiency, smart use of energy Econo mode
Seasonal efficiency gives a more realistic indication on how This function decreases the power consumption so that other
efficient air conditioners operate over an entire heating or cooling applicances that need large power consumption can be used.
season. This function is also energy saving.
Auto-cleaning filter Movement sensor
The filter automatically cleans itself. Simplicity of upkeep means The sensor detects whether someone is in the room. When
optimum energy efficiency and maximum comfort without the the room is empty, the unit switches to economy mode after
need for expensive or time-consuming maintenance. 20 minutes and restarts when a person enters the room.
Inverter technology
Inverter compressors continuously adjust compressor speed to
actual demand. Fewer power-consuming starts and stops result
in decreased energy consumption (up to 30%) and more stable
Home leave operation
During absence, the indoor temperature can be maintained at
a certain level.
A big step setting the
temperatures.
2 area intelligent eye
Air flow is sent to a zone other than where the person is located
at that moment. Detection is done in 2 directions: left and right. If
no people are detected, the unit will automatically switch over to
the energy-efficient setting.
Fan only
The air conditioner can be used as fan, blowing air without
cooling or heating. new heat pump standard General catalogue
3 area intelligent eye Free cooling
Air flow is sent to a zone other than where the person is located By exploiting the low external air temperatures to cool the water,
at that moment. Detection is done in 3 directions : left, front and
2018
free cooling reduces the load on the compressors and decreases
3 right. If no people are detected, the unit will automatically switch considerably the annual operating costs during the cold season.
over to the energy-efficient setting and eventually switch off.
Floor & presence sensor
Energy saving during operation standby The presence sensor directs the air away from any person
Current consumption is reduced by about 80 % when operating detected in the room, when the air flow control is on. The floor
on standby. sensor detects the average floor temperature and ensures an even
temperature distribution between ceiling and floor.
GENERAL C ATA L O G U E 2 0 1 8
Comfort
Comfort mode Draught prevention
The unit automatically changes the angle of the air discharge louvre When starting to warm up or when the thermostat is off, the air
depending on the mode. In cooling operation the air will be directed discharge direction is set horizontally and the fan to low speed, to
rather upwards to avoid cold draught, while in heating operation the prevent draught. After warming up, air discharge and fan speed
air will be directed rather downwards to avoid cold feet. are set as desired.
Powerful mode Auto cooling-heating changeover
If the temperature in the room is too high/low, it can be cooled Automatically selects cooling or heating mode to achieve
down/heated quickly by selecting the ‘powerful mode’. After the the set temperature (heat pump types only).
powerful mode is turned off, the unit returns to the preset mode.
IS
Increased comfort function that follows a specific temperature eliminates the risk of bacteria and legionella. Rest assured that
fluctuation rhythm. your hot water is fresh and safe Seasonal efficiency and operation range down to -25°C.
Air flow Easy to install - The floor standing unit only has a 60 cm2
footprint and you can choose for white or silver-grey colour. HE M HE M
3-D Air flow
IN T
IN T
IS
IS
Ceiling soiling prevention This function combines Vertical and Horizontal auto-swing to
S I ON
S I ON
A special function prevents air blowing out too long in horizontal circulate a stream of cool/warm air right to the corners of even
position, to prevent ceiling stains. large spaces. Easy to control - Fully digital, the Daikin Altherma 3 can be
JO
JO
48
Tools and
platforms
Literature overview 50
Supporting tools, software and apps 52
49
Commercial market - literature overview
for professional network
Solution
guides:
Reference
books:
features and
207 116 examples,
specs of VRV IV
technical
VRV IV heat recovery, heat pump, replacement
Keep looking
you’ll never find me Main benefits, background
206 application examples
and specs of VRV IV 209
PE
RELIABLE,
Infrastructure
technology Clear installer benefits cooling solution
for installers
of VRV replacement infrastructure cooling
technology
214 140
The quick and quality way of upgrading R-22 and R-407C systems
Product
Real time clock
Modbus
Specifications / Functions
Specifications
Dimensions (HxWxD)
Display size (HxW)
BRC1E52A / BRC1E52B
3.120x120x19 mm40
43.2x68.85 mm
User friendly
remote control 52A/B remote control Interface controls and applications
with contemporary
LCD
Type Full dot (160x255)
Colour
Cover for operation part
Max. wiring length
Fresh white
No
500m
RTD
design
Connectable indoor units All VRV® and Sky Air® indoor units
› Easy to use: all main functions directly accessible › Set up to 3 independent schedules, so the user can
easily change the schedule himself throughout the
Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor) › Easy commissioning: intuitive interface for advanced year (e.g. summer, winter, mid-season)
menu settings
› Real time clock with auto update to daylight saving
FSC › Optimise your air conditioning system by activating a time
series of energy saving functions (temperature range
ECPEN15 - 306 180 · 11/14 limit, setback function, off timer, …) › Supports multiple languages Integration of Daikin portfolio in BMS system via Modbus
308
The present publication is drawn up by way of information only and does not constitute an offer binding upon
306
Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its › Keep track of your energy consumption with the › Possibility to individually restrict menu functions › Indoor unit control › Retail applications
content and the products and services presented therein. Specifications are subject to change without prior notice.
kWh indication showing an indicative electricity via 0~10 volt, dry contact › Hotel applications
Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from
or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V. consumption › When a power failure occurs all settings remain stored or resistance contact › IT applications
The present publication supersedes ECPEN12-306. Printed on non-chlorinated paper. up to 48 hours thanks to the built-in backup power › Heating interlock
› Alarm signal
ErP1
THE BEST OUR BIM
PART
NER VISIT
TION new
Minimum running costs, FOR GREE
N APPLICA
ON
Modular L
liant ING SUITE
Get ahead of competition maximum flexibility. comp BUILD AIKIN.E
U/BIM
Fresh air for the residential and commercial sector
50
Tools and platforms
216
100
Sustainable design
with Daikin HVAC-R systems
Reference
catalogue
Daikin commercial Hotel Solutions
and industrial Hotel solutions
Clear building owner/investor
references for hotel owners
benefits why to choose Daikin
Heating - air conditioning - hot water - ventilation - refrigeration - control
for a hotel
218
213
Intelligent Touch
Intelligent Touch Manager intelligent
Tablet Controller and Daikin Cloud Service
with cloud connection
Manager
302 303
Mini Building Management System Your business at your fingertips
215
ESP
FBQ-D, FXSQ-A
individual Sky Air unit. Ideal for VRV unit. Ideal for quotations
quotations
Designed to be concealed in walls Optimum comfort guaranteed no matter the
Home leave
Home leave length of ductwork or type of grilles
operation
operation › Ideal for installation in offices, hotels and residential › Discretely concealed in the wall, leaving only the
› Top efficiency in the market › Medium external static pressure up to 150Pa facilitates
applications suction and discharge grilles visible
› Automatic air flow adjustment function measures the using flexible ducts of varying lengths
› Its low height enables the unit to fit perfectly beneath › Requires very little installation space as the depth is
air volume and static pressure and adjusts it towards › Reduced energy consumption thanks to specially
a window only 200mm
Powerful mode the nominal air flow, whatever the length of duct, developed DC fan motor
Powerful mode › High ESP allows flexible installation
making installation easier and guaranteeing comfort. › Flexible installation, as the air suction direction can be
Moreover, the ESP can be changed via the wired altered from rear to bottom suction
remote control to optimize the supply air volume › Standard built-in drain pump increases flexibility and
Multi tenant
Multi tenant (FXSQ) › Slimmest unit in class, only 245mm installation speed
(FXNQ-A)
› Discretely concealed in the ceiling: only the suction › No optional adapter needed for DIII-connection, link
and discharge grilles are visible your unit into the wider building management system
› Low sound level
Technical documentation:
All latest Daikin catalogues are available in
a convenient library on the internet:
www.daikineurope.com/support-and-manuals/catalogues
51
Supporting www.daikineurope.com/
support-and-manuals/
›› Web & cloudbased access to your projects from ›› No need to do local installation
anywhere, at any time… ›› No tool updates required
›› Platform (Windows, Mac, …) and hardware (always latest version available)
(laptop, desktop, tablet) independent ›› Possibility to copy / share projects
›› Re-engineered GUI for maximum easy of use
Main functions
Detailed properties
Clear wiring overview, easy to make control groups Clear overview of control groups and central controls
52
Other selection software
VRV Pro Ventilation Xpress
Enables VRV air conditioning systems to be Selection tool for ventilation devices (VAM, VKM). The
engineered in a precise and economical way, taking selection is based on given supply/extract airflows
into account the complex piping rules. Moreover, it (including fresh up and given ESP of supply/extract
ensures optimum operating cycles and maximum ducting):
energy efficiency. ›› Determines size of electrical heaters
›› Accurate heat load calculation ›› Visualisation of psychrometric chart
›› Precise selection based on peak loads ›› Visualisation of selected configuration
›› Energy consumption indication ›› Required field settings mentioned in the report
53
Plug-ins and third-party software tools
Building Information Modelling www.daikin.eu/
(BIM) support
bim
›› BIM improves efficiency of design and build phase
›› Daikin is among the first
to supply a full library of BIM objects
for its VRV products
VRV CAD 2D
http://www.
›› Displays VRV pipe design on a Autocad 2D
floorplan daikineurope.
›› Improves project management com/autocad/
›› Accurately calculates the pipe dimensions and
refnets index.jsp
›› Determines the outdoor unit size
›› Validates VRV pipe rules
›› Accounts for the extra refrigerant charge,
including a max room concentration check
Seasonal simulator
54
Service tools
Error code app
D-Checker
VRV Service-Checker
my.daikin.eu
ON ›› Get more commercial details on our flagship
THE products via our dedicated minisites
R OA D
AT ›› See our references
CUSTOME
RS
TOOLS & PLATFORMS
www.daikineurope.com/references
55
56
Technical
drawings
ALB-RBS / LBS 58
VAM-J/FC 64
VKM-GB(M)
TECHNICAL DRAWINGS
57
VIEW ALL ALB-LBS DRAWINGS
ON MY.DAIKIN.EU
Detailed technical drawings
ALB02RBS/LBS
CONDENSATE
OUTLET 1/4”G
ELECTRIC
SWITCH BOX
ALB03RBS/LBS
TOP VIEW
ELECTRIC
SWITCH
BOX
58
VIEW ALL ALB-RBS DRAWINGS
ON MY.DAIKIN.EU
Detailed technical drawings
ALB04RBS/LBS
CONDENSATE
OUTLET 1/4”G
TOP VIEW
BOTTOM VIEW
ELECTRIC
SWITCH
BOX
ALB05RBS/LBS
CONDENSATE
OUTLET 1/4”G
TOP VIEW
BOTTOM VIEW
ELECTRIC
SWITCH
TECHNICAL DRAWINGS
BOX
59
VIEW ALL ALB-LBS DRAWINGS
ON MY.DAIKIN.EU
Detailed technical drawings
ALB06RBS/LBS
CONDENSATE
OUTLET 1/4”G
TOP VIEW
BOTTOM VIEW
ELECTRIC
SWITCH BOX
ALB07RBS/LBS
CONDENSATE
OUTLET 1/4”G
TOP VIEW
BOTTOM VIEW
ELECTRIC
SWITCH
BOX
60
VIEW ALL ALB-RBS DRAWINGS
ON MY.DAIKIN.EU
Detailed technical drawings
ALB02RBS/LBS
The diagram shows the available external pressure for the duct
system given an airflow.
SFPv = Specific Fan Power (W/m3/s)
The SFPv curves are referring to the complete unit. Moreover, it
includes power to both supply and extract fan divided by either
the supply or extract volume whichever is the greater.
ALB03RBS/LBS
The diagram shows the available external pressure for the duct
system given an airflow.
SFPv = Specific Fan Power (W/m3/s)
The SFPv curves are referring to the complete unit. Moreover, it
includes power to both supply and extract fan divided by either
the supply or extract volume whichever is the greater.
TECHNICAL DRAWINGS
61
VIEW ALL ALB-LBS DRAWINGS
ON MY.DAIKIN.EU
Detailed technical drawings
ALB04RBS/LBS
The diagram shows the available external pressure for the duct
system given an airflow.
SFPv = Specific Fan Power (W/m3/s)
The SFPv curves are referring to the complete unit. Moreover, it
includes power to both supply and extract fan divided by either
the supply or extract volume whichever is the greater.
ALB05RBS/LBS
The diagram shows the available external pressure for the duct
system given an airflow.
SFPv = Specific Fan Power (W/m3/s)
The SFPv curves are referring to the complete unit. Moreover, it
includes power to both supply and extract fan divided by either
the supply or extract volume whichever is the greater.
62
VIEW ALL ALB-RBS DRAWINGS
ON MY.DAIKIN.EU
Detailed technical drawings
ALB06RBS/LBS
The diagram shows the available external pressure for the duct
system given an airflow.
SFPv = Specific Fan Power (W/m3/s)
The SFPv curves are referring to the complete unit. Moreover, it
includes power to both supply and extract fan divided by either
the supply or extract volume whichever is the greater.
ALB07RBS/LBS
The diagram shows the available external pressure for the duct
system given an airflow.
SFPv = Specific Fan Power (W/m3/s)
The SFPv curves are referring to the complete unit. Moreover, it
includes power to both supply and extract fan divided by either
the supply or extract volume whichever is the greater.
TECHNICAL DRAWINGS
63
VIEW ALL VAM-FC TECHNICAL VIEW ALL VAM-J TECHNICAL
DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VAM150FC
VAM150FA
Maintenance space for the heat exchange elements, the air filters and fans
Switch box
Ceiling hook
Inspection hole 4-14x40 oval hole
285 Ø 450
120~250
600
Maintenance over 104 120.3
149
20
67
SA OA
Supply air to room 124 164
124
Fresh air from outdoors
288
509
560
(Outdoor air)
288
164
RA EA
Return air from room Exhaust air to outdoors
8 Sealing Sealing
8
20
149
Damper plate
Exhaust air fan
(Maintenance cover) Exhaust spacer
(Switch box)
145 760 145
Ø200
Ø97
Heat exchange elements Air filters
NOTE
1 Be sure to provide the inspection hole (450x450 mm) to inspect the air filters, the exchange elements and fans.
3TW27874-1
VAM250FC
VAM250FA
Maintenance space for the heat exchange elements, the air filters and fans
Switch box
Ceiling hook
Inspection hole
285 Ø 450 4-14x40 oval hole
SA
OA
Supply air to room
124 164
124
560
288
(Outdoor air)
164
RA EA
Return air from room Exhaust air to outdoors
8
Sealing Sealing
8
149
Damper plate
Exhaust air fan
(Maintenance cover)
(Switch box)
145 760 145
Ø200
Ø97
NOTE
1 Be sure to provide the inspection hole (450x450 mm) to inspect the air filters, the exchange elements and fans.
3TW27884-1
64
VIEW ALL VAM-J TECHNICAL VIEW ALL VAM-FC TECHNICAL
DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VAM350-500J
VAM350-500J
Ceiling hook
4 - 12 x 40mm oblong hole Damper panel
305
304.8 Exhaust air fan
10 284.8 10 1045 112.3
112
112.3
122 Sealing material
22
6
Sealing material
RA
Return air from room
EA
291.6
292
137
126.8
Exhaust air to outdoors
417
126.2
126
Exhaust air Room air 162.8
173
899.4
891.4
834
899
866
891
162.8
173
SA
125.4
125
Sealing material
417
126.8
137
Supply air to room
290.8
291
Supply air
OA
Supply air fan
Fresh outdoor air
Outdoor air Sealing material
191.4
190
22
112.3
122 112.3
122
200 - 300
Sealing material
≥675
Sealing material
475
Inspection hole
Maintenance space for the air filters, heat exchangers and fans
Switch box
900
Heat exchanger
84
78 1101
1113 84
78
6 6
Switch box
Ø 213
Ø 197
VAM650J
VAM650J
Ceiling hook
368 Exhaust air fan 4 - 12 x 40mm oblong hole Damper panel
1266
154
22
211
941
920
949
211
493
162
220
Sealing material
272
SA
Supply air to room
OA
Supply air
Fresh outdoor air Supply air fan
186
Sealing material
22
Outdoor air
154
154 Sealing material
200 - 300
≥ 700
Sealing material
500
Inspection hole
Maintenance space for the air filters, heat exchangers and fans
Switch box
1100
Heat exchanger
83 1354 83
Switch box
Ø262
Ø245
TECHNICAL DRAWINGS
VAM800-1000J
VAM800-1000J
Ceiling hook
368 4 - 12 x 40mm oblong hole Damper panel
Exhaust air fan 1266
154 154
Sealing material
22
6
Sealing material
RA
399
Exhaust air to outdoors
239
(606)
212 Room air
1204
1197
1172
(628)
Sealing material
207
162 SA
389
Supply air to room
OA Supply air
212
Fresh outdoor air Sealing material
192
22
154 154
Sealing material
200-300
≥850
Sealing material
Inspection hole
Maintenance space for the air filters, heat exchangers and fans 650
Switch box
1100
Heat exchanger
83 1354 83
Sealing material
Ø262
Ø245
3D112817C
VAM1500-2000J
VAM1500-2000J
731
Ceiling hook Damper panel
(2x) Exhaust air fan
4 - 14 x 40mm oblong hole
1266 (4x) Option EKPLEN200
384 150 Sealing material 150 345
20
(577)
Room air
1219
1172
1198
(599)
Exhaust air
218
SA
348
(2x)
345 150
Sealing material Sealing material 150 384
200 - 300
≥850
Maintenance space for the air filters, heat exchangers and fans
Switch box
1100
Heat exchanger
130 261 1354 261 130
26
Sealing material
Option KRP2A51
Mounting
Ø330
Ø350
405
621
Option BRP4A50A
(10)
24
66
VAM150FC
VIEW ALL VAM-J TECHNICAL VIEW ALL VAM-FC TECHNICAL
DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VAM150FC
250 20m
200
15m
External static pressure [Pa]
150 Ultra-high
10m
100
High
Low 5m
50
Ø 100
Pipe length
0
0 50 100 150 200 250
Air flow rate [m³/h]
Notes
1. The fan speeds are valid for ·230·V, ·50·Hz power supply.
4D100379
TECHNICAL DRAWINGS
67
VIEW ALL VAM-FC TECHNICAL VIEW ALL VAM-J TECHNICAL
VAM250FC DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VAM250FC
250
200
Ultra-high
External static pressure [Pa]
Ø 150
150
Pipe length
High
100 40m
Low 30m
50 20m
10m
0
0 50 100 150 200 250 300
Air flow rate [m³/h]
Notes
1. The fan speeds are valid for ·230·V, ·50·Hz power supply.
4D100380
VAM350J
VAM350J
250
Ultra-high speed
200
External static pressure [Pa]
External static pressure [Pa]
300
250
150 250
200
200
100 150
150
100 UH15
100
50
50
50 UH8
Ø200 UH1
0 Duct lenght 0
450
150150 100 150 200 250 300 350 400 450 150 200 250 300 350 400
200 200
150 150
100 100
H15
50 50
H1 H8 L1
($" L15
0 0
150 200 250 300 350 400 450 ()"
L8
100 150 200 250 300 350 400 450
Legend
Notes L1 = Low speed lower limit
1. The fan curves are determined with ·1/3· of the ESP on the outdoor side L8 = Low speed factory setting
(·EA & OA·), and ·2/3· of the ESP on the indoor side (·RA & SA·). L15 = Low speed upper limit
EA= Exhaust air H1 = High speed lower limit
Ultra-high speed H8 = High speed factory setting
OA= Outdoor air
High speed H15 = High speed upper limit
RA = Room air
Low speed UH1 = Ultra-high speed lower limit
SA = Supply air
UH8 = Ultra-high speed factory setting
2. Measured according to ·JIS B 8628 - 2003·
UH15 = Ultra-high speed upper limit
3D113493
68
VIEW ALL VAM-J TECHNICAL VIEW ALL VAM-FC TECHNICAL
DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VAM500J
VAM500J
250
200m
External static pressure [Pa] UH15
Ultra-high speed
200
150 200
H8 120m
UH1
L15 150
100
80m 100
H1
UH15
L8 50
UH8
50
40m UH1
0
L1 250 300 350 400 450 500 550 600
Ø200
0 Duct length
150 200 250 300 350 400 450 500 550 600
Air flow rate [m³/h]
Air flow rate [m³/h]
External static pressure [Pa]
150 150
100 100
50 50
H15
L15
H1 0 L1
0 H8 L8
200 250 300 350 400 450 500 550 600 150 200 250 300 350 400 450 500
VAM650J
VAM650J
250
External static pressure [Pa]
H15
150 160m
H8 200
UH1
L15 120m 150
100
H1
L8
800m 100 UH15
50
40m 50 UH8
L1 Ø250 UH1
0 Duct Length 0
250 350 450 550 650 750 350 450 550 650 750
Air flow rate [m³/h] Air flow rate [m³/h]
High speed Low speed
250 200
External static pressure [Pa]
External static pressure [Pa]
200
150
150
100
100
50
50 H15 L15
0 H1 H8 0 L1
L8
250 350 450 550 650 750 250 350 450 550 650 750
Air flow rate [m³/h] Air flow rate [m³/h]
Legend
Notes L1= Low speed lower limit
1. The fan curves are determined with 1/3 of the ESP on the L8= Low speed factory setting
TECHNICAL DRAWINGS
outdoor side (EA & OA), and 2/3 of the ESP on the indoor side (RA & SA). Ultra-high speed L15= Low speed upper limit
EA = Exhaust air H1= High speed lower limit
OA = Outdoor air High speed H8= High speed factory setting
RA = Room air H15= High speed upper limit
SA = Supply air UH1= Ultra-high speed lower limit
2. Measured according to JIS B 8628 - 2003 Low speed UH8= Ultra-high speed factory setting
UH15= Ultra-high speed upper limit
3D113495A
69
VIEW ALL VAM-FC TECHNICAL VIEW ALL VAM-J TECHNICAL
DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VAM800J
VAM800J
300
UH15 Ultra-high speed
250 350
H15 180m
External static pressure[PA]
300
250 200
200
150
150
100
100 H15
50 50
L15
0 H1 H8 0 L1
L8
400 500 600 700 800 900 300 400 500 600 700 800 900
Air flow rate [m3/h] Air flow rate [m3/h]
Legend
Notes L1= Low speed lower limit
L8= Low speed factory setting
1. The fan curves are determined with ·1/3· of the ESP on the outdoor side L15= Low speed upper limit
(·EA & OA·), and ·2/3· of the ESP on the indoor side (·RA & SA·). H1= High speed lower limit
EA = Exhaust air Ultra-high speed
H8= High speed factory setting
OA = Outdoor air H15= High speed upper limit
RA= Room air High speed
UH1= Ultra-high speed lower limit
SA = Supply air UH8= Ultra-high speed factory setting
2. Measured according to ·JIS B 8628 - 2003· Low speed
UH15= Ultra-high speed upper limit
3D112837
VAM1000J
300 Ultra-high speed
150m
UH15
350
250
UH8 120m 300
200 H15
External static
pressure [Pa]
250
UH1 90m
H8
External static
pressure [Pa]
150 200
L15
H1 150
100 UH15
L8 100
50 30m 50 UH8
L1 Ø250
Duct lenght 0 UH1
0
400 500 600 700 800 900 1000 1100 600 700 800 900 1000 1100
Air flow rate [m3/h] Air flow rate [m3/h]
200
200
150
150
100
100
H15
50
50 L15
0 L1
0 H1 H8
400 500 600 700 L8 800 900
500 600 700 800 900 1000
Air flow rate [m3/h] Air flow rate [m3/h]
Notes Legend
1.The fan curves are determined with ·1/3· of the ESP on the outdoor side (·EA & OA·), L1 = Low speed lower limit
and ·2/3· of the ESP on the indoor side (·RA & SA). LB = Low speed factory setting
L15 = Low speed upper limit
EA= Exhaust air Ultra-high speed H1 = High speed lower limit
OA = Outdoor air High speed H8 = High speed factory setting
RA= Room air Low speed H15 = High speed upper limit
SA= Supply air UH1 = Ultra-high speed lower limit
UH8 = Ultra-high speed factory setting
2. Measured according to ·JIS B 8628 - 2003· UH15 = Ultra-high speed upper limit
3D112832
70
VIEW ALL VAM-J TECHNICAL VIEW ALL VAM-FC TECHNICAL
DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VAM1500J
VAM1500J
300
UH15
External static pressure [Pa]
250
Ultra-high speed
350
H15
200 180m
250
200
200
150
150
100
100 H15
50 L15
50
H1 H8
0 0
L1 L8
700 900 1100 1300 1500 1700 700 900 1100 1300 1500
Air flow rate [m³/h]
Air flow rate [m³/h]
Legend
L1 = Low speed lower limit
Notes
1. The fan curves are determined with ·1/3· of the ESP on the outdoor side (·EA & OA·),and ·2/3· of the ESP on the indoor side (·RA & SA·). L8 = Low speed factory setting
EA = Exhaust air L15 = Low speed upper limit
OA = Outdoor air H1 = High speed lower limit
RA = Room air H8 = High speed factory setting
SA = Supply air H15 = High speed upper limit
2 .Measured according to ·JIS B 8628 - 2003· Ultra-high speed UH1 = Ultra-high speed lower limit
High speed
Low speed UH8 = Ultra-high speed factory setting
UH15 = Ultra-high speed upper limit 3D112838
VAM2000J
VAM2000J
300
150m
UH15
250
120m
Ultra-high speed
350
UH8
External static pressure [Pa]
External static pressure [Pa]
H15
200 300
UH1 90m
250
H8
150
L15 200
H1 60m
150
100
L8 UH15
100
30m
50
L1 50 UH8
2xØ250
Duct length 0 UH1
0 1200 1400 1600 1800 2000 2200
800 1000 1200 1400 1600 1800 2000 2200
Air flow rate [m³/h] Air flow rate [m³/h]
High speed Low speed
300 250
External static pressure [Pa]
External static pressure [Pa]
250
200
200
150
150
100
100
H15
50
50
L15
H1 H8 L1
0 0
L8
1000 1200 1400 1600 1800 2000 800 1000 1200 1400 1600 1800
Notes
Legend
L1 = Low speed lower limit
1. The fan curves aredetermined with ·1/3· of the ESP on the outdoor side (·EA & OA·), and ·2/3· of the ESP on the indoor side (·RA &SA·). L8 = Low speed factory setting
EA=Exhaust air L15 = Low speed upper limit
OA=Outdoor air
TECHNICAL DRAWINGS
71
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VKM50GB
VKM50GB
EA Heat insulated
(Exhaust air to outdoors) Branch duct (locally procured)
(locally procured)
Round shape hood
(locally procured)
OA
(Fresh air to outdoors)
Control box
OA
(Fresh air to outdoors)
EA
(Exhaust air to outdoors)
Suspention bolt
Sloping downwards at (locally procured) SA
Inspection hatch RA
a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)
NOTES
1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easily be
inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation.(Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
5. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
6. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
7. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
8. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up,
or the air filter is very dirty.
3D083014
72
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VKM50GBM
VKM50GBM
Heat insulated
EA (locally procured)
(Exhaust air to outdoors) Branch duct
Round shape hood (locally procured)
(locally procured)
OA
(Fresh air to outdoors)
Control box
OA
(Fresh air to outdoors)
EA
(Exhaust air to outdoors)
□ 450 - 600 Suspention bolt
(locally procured)
Sloping downwards at Inspection hatch RA SA
a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)
NOTES
1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easily be
inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Use city water or clean water.
Include water supply piping with strainer, a water supply shut-off valve, and a drain valve (both locally procured) somewhere along the water supply piping that can be reached from the
inspection.
5. It is impossible to connect the water supply piping directly to public piping. Use a cistern tank (of the approved type), if you need to get your water supply from public piping.
6. Make sure the supply water 0.02MPa to 0.49MPa (0.2 kg/cm2 to 5 kg/cm2 )
7. Make sure the supply water is between 5°C and 40°C in temperature.
8. Insulate the water supply piping to prevent condensation from forming.
9. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
10. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
11. Install in a location where the air around the unit or taken into the humidifier will not drop below 0°C.
12. Do not use a bent cap or a round hoodas the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
13. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
14. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the
air filter is very dirty.
15. Feed clean water. If the supply water is hard water, use a water softener because of short life.
Life of humidifying element is about 3 years (4,000 hours), under the supply water conditions of hardness: 150 mg/L. (Life of humidifying element is about 1 years (1500 hours), under the
supply water conditions of hardness: 400 mg/L.)
TECHNICAL DRAWINGS
3D083011
73
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VKM80GB
VKM80GB
Heat insulated
EA Branch duct (locally procured)
(Exhaust air to outdoors)
(locally procured)
Round shape hood
(locally procured)
OA Silencer
(Fresh air to outdoors)
(locally procured)
Control box Flexible duct Air discharge grille
OA
(Fresh air to outdoors)
EA
(Exhaust air to outdoors)
□ 450 - 600 Suspention bolt
(locally procured)
Sloping downwards at Inspection hatch RA SA
a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)
NOTES
1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easily be
inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
5. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
6. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
7. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
8. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the
air filter is very dirty.
3D083015
74
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VKM80GBM
VKM80GBM
Heat insulated
EA Branch duct (locally procured)
(Exhaust air to outdoors)
(locally procured)
Round shape hood
(locally procured)
OA
(Fresh air to outdoors) Silencer
(locally procured)
Control box Flexible duct Air discharge grille
OA
(Fresh air to outdoors)
EA
(Exhaust air to outdoors) Suspention bolt
□ 450 - 600 (locally procured)
Sloping downwards at Inspection hatch RA SA
a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)
NOTES
1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easilybe
inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Use city water or clean water.
Include water supply piping with strainer, a water supply shut-off valve, and a drain valve (both locally procured) somewhere along the water supply piping that can be reached from the
inspection
5. It is impossible to connect the water supply piping directly to public piping. Use a cistern tank (of the approved type), if you need to get your water supply from public piping.
6. Make sure the supply water 0.02MPa to 0.49MPa (0.2 kg/cm2 to 5 kg/cm2 )
7. Make sure the supply water is between 5°C and 40°C in temperature.
8. Insulate the water supply piping to prevent condensation from forming.
9. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
10. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
11. Install in a location where the air around the unit or taken into the umidifier will not drop below 0°C.
12. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
13. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
14. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case,where humidity is 80% more, or the exit of drain socket is choked up, or the
air filter is very dirty.
15. Feed clean water. If the supply water is hard water, use a water softener because of short life.
Life of humidifying element is about 3 years (4,000 hours), under the supply water conditions of hardness: 150 mg/L. (Life of humidifying element is about 1 years (1500 hours), under the
supply water conditions of hardness: 400 mg/L.)
TECHNICAL DRAWINGS
3D083012
75
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VKM100GB
VKM100GB
Heat insulated
EA Branch duct (locally procured)
(Exhaust air to outdoors)
(locally procured)
Round shape hood
(locally procured)
OA Silencer
(Fresh air to outdoors)
(locally procured)
Control box Flexible duct Air discharge grille
OA
(Fresh air to outdoors)
EA
(Exhaust air to outdoors)
□ 450 - 600 Suspention bolt
Sloping downwards at Inspection hatch (locally procured) RA SA
a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)
NOTES
1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easily be
inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
5. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
6. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
7. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
8. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the
air filter is very dirty.
3D083016
76
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VKM100GBM
VKM100GBM
Heat insulator
EA Branch duct (locally procured)
(Exhaust air to outdoors)
(locally procured)
Round shape hood
(Locally procured)
OA Silencer
(Fresh air from outdoors)
(locally procured)
Control box Flexible duct Air discharge grille
OA
(Fresh air from outdoors)
EA
(Exhaust air to outdoors) Suspension bolt
□ 450 • 600
Sloping downwards at a Inspection hatch (locally procured) RA SA
gradient of the 1/100 (Return air from room) (Return air to room)
(locally procured)
NOTES
1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters, heat exchange elements, fans and humidifier
elements can easily be inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water. Also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Use city water or clean water.
Include water supply piping with strainer, a water supply shut-off valve, and a drain valve (both locally procured) somewhere along the water supply piping that can be reached from the
inspection.
5. It is impossible to connect the water supply piping directly to public piping. Use a cistern tank (of the approved type), if you need to get your water supply from public piping.
6. Make sure the supply water 0.02MPa to 0.49MPa (0.2 kg/cm2 to 5 kg/cm2 )
7. Make sure the supply water is between 5°C and 40°C in temperature.
8. Insulate the water supply piping to prevent condensation from forming.
9. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
10. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
11. Install in a location where the air around the unit or taken into the humidifier will not drop below 0°C.
12. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
13. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
14. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the
air filter is very dirty.
15. Feed clean water. If the supply water is hard water, use a water softener because of short life.
Life of humidifying element is about 3 years (4,000 hours), under the supply water conditions of hardness: 150 mg/L. (Life of humidifying element is about 1 years (1500 hours), under the
supply water conditions of hardness: 400 mg/L.)
TECHNICAL DRAWINGS
3D083013
77
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VKM50GB
VKM50GB
–––––– 50Hz, 220V-240V Exchange
efficiency
Operating air flow rate range (%)
Temp
eratu
re ex
chan
ge eff
Enth icienc Operating air flow rate range Operating air flow rate range Operating air flow rate range
alpy y
exch
ange
efficie
Enth ncy (
alpy heati
exch ng)
ange
effic ø200
ienc
y (co
oling Pipe
)
length
External static pressure (Pa)
Ultra High
High
Low
Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h]
Low High Ultra High
VKM50GBM
VKM50GBM
–––––– 50Hz, 220V-240V Exchange
efficiency
Operating air flow rate range (%)
Temp VKM50GBM
erature
excha
nge e
Enth fficien
alpy cy
exch
ange
effic
ienc
Enth y (he
alpy
exch
ating
) Operating air flow rate range Operating air flow rate range Operating air flow rate range
ange
efficie ø200
ncy (
cooli Pipe
ng)
External static pressure (Pa)
length
External static pressure (Pa)
Ultra High
High
Low
Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h]
Low High Ultra High
78
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VKM80GB
VKM80GB
–––––– 50Hz, 220V-240V Exchange
efficiency
Operating air flow rate range (%) Operating air flow rate range Operating air flow rate range Operating air flow rate range
Tem
pera
ture
exch
ange
Enth efficie
alpy ncy
exch
ange
effic
Enth ienc
alpy y (he
exch ating
effic
ienc
y (co
oling
)
Ultra High
High ø250
Pipe
length
Low
Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h]
Low High Ultra High
VKM80GBM
VKM80GBM
–––––– 50Hz, 220V-240V
Exchange
Operating air flow efficiency
Operating air flow rate range Operating air flow rate range Operating air flow rate range
rate range (%)
VKM80GBM
Tempe
rature e
xchang
Enth e efficie
alpy ncy
exch
ang
e ef
Enth ficie
External static pressure (Pa)
alpy ncy
exch (hea
External static pressure (Pa)
ange ting)
effic
ienc
y (co
oling
)
Low
Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h]
Low High Ultra High
79
VIEW ALL VKM-GB(M) TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VKM100GB
VKM100GB
–––––– 50Hz, 220V-240V
Exchange
efficiency
Operating air flow rate range (%)
Operating air flow rate range Operating air flow rate range Operating air flow rate range
Tem
pera
Ent ture
halp exc
y ex han
cha ge e
nge fficie
effic ncy
ienc
Ent y (h
eatin
External static pressure (Pa)
hal g)
py
exc
han
ge
effi
High
Low
VKM100GBM
VKM100GBM
–––––– 50Hz, 220V-240V Exchange efficiency
(%)
Operating air flow rate range Operating air flow rate range Operating air flow rate range
VKM100GBM
Tem
pera
ture
En exc
tha han
lpy ge e
exc fficie
han ncy
External static pressure (Pa)
ge
effi
En cie
tha ncy
lpy (he
exc atin
han
External static pressure (Pa)
g)
ge
effi
cie
ncy ø200
(co
olin Pipe
g)
length
Ultra High
High
Low
Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h]
Low High Ultra High
80
Notes
81
TECHNICAL DRAWINGS
Notes
82
83
Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Publisher)
The present publication is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has
compiled the content of this publication to the best of its knowledge. No express
or implied warranty is given for the completeness, accuracy, reliability or fitness
for particular purpose of its content and the products and services presented
ECPEN19-20312/18 therein. Specifications are subject to change without prior notice. Daikin Europe
N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest
sense, arising from or related to the use and/or interpretation of this publication.
All content is copyrighted by Daikin Europe N.V.