Sie sind auf Seite 1von 2

1-4

Dimmer circuit
Approx height 300

Dimmer circuit to
Approx height 3000

Dimmer circuit to Ladder access to


underside balcony
former swimming

16
pool void

13-
CLEANERS
CUPBOARD 3100 5-8

Edge of balcony
over

Dimmer circuit
Approx height 4500

8
17-2
Dimmer circuit
Approx height 3500

DRESSING To ceiling at MODULAR TIERED SEATING 52-5


5
first floor level SYSTEM CAPACITY APPROX
ROOM
7670 135 AS DRAWN

2450

Dimmer circuit
Approx height 4500
97-105 106-109

Dimmer circuit
Up to W.C.'s Approx height 3500
and Showers

6670
Apex of glazing 2500
overhead
2500
BOX OFFICE

LIFT High level glazing


93-96 Manhole access 33-38
to pool void over truss
4435
2,700

Up from Theatre Bar To underside To ceiling at


5530 2300
of beam over first floor level
Dimmer circuit Dimmer circuit
Approx height 3250 Approx height 3250

Edge of balcony
TAB TRACK 2530
SPIRAL
7,500
STAIR
7,700

2290

CLEAR STAGE AREA


SHOWN DOTTED
76-79

2
29-3

Dimmer circuit Dimmer circuit


Approx height 500 Approx height 500
Manhole access
to pool void

EDGE OF BALCONY
OVERHEAD

6.650 Edge of former


2320 swimming pool
Fire Exit 64-67
from Bar
Dimmer circuit to
underside balcony

ENTRY FROM
BRIDE LANE

BRIDE LANE

C 08/07/05 LIGHTING POINTS ADDED


B 08/04/05 SEAT NUMBERS REVISED
Revisions: A 07/03/05 FIRST ISSUED
ROBSON WARREN Architects Project: Drawing: Date: 11/07/2005

8 Northfields Prospect, Putney Bridge Rd ST. BRIDE FOUNDATION INSTITUTE ST BRIDE THEATRE Drawn by: SM
London SW18 1PE BRIDE LANE FLEET ST MAIN HALL Checked: PW
Telephone: 020-8871 9349 ROOM STUDIES Scale: 1:100
Facsimile: 020-8871 9489
LONDON EC4Y 8EQ ORIGINAL SCALE 1:100 at A3 Job No: 2201
0 1 2 3 4m
E-mail: robsonwarren@clara.co.uk FOR: THE GOVERNORS Dwg No: SK/10 Revision C
Dimmer circuit
Approx height 6650

9.003

2
9 -1
4100
To beam from
REAR Balcony level
BALCONY
Edge of Balcony

Dimmer circuit
Approx height 3600 LIGHTING / SOUND
114-121 110-113

DESK LOCATION
OVER SEATING

7300
Dimmer circuit To beam from
Approx height 6650 Hall level
7670
To ceiling from
Hall level

REFER TO MAIN
THEATRE PLAN BELOW
FOR SEATING LAYOUT

VOID OVER
THEATRE

84-92 39-47

Dimmer circuit Dimmer circuit


Approx height 4700 5530 Approx height 4700
To ceiling from
basement
Edge of Balcony
Handrail

TAB TRACK AT Riveted cast


SPIRAL 1910
HIGH LEVEL iron girders
STAIR

2540 80-83 48-51

Dimmer circuit on Dimmer circuit


Beam height 5100 Approx height 5100

DIMMER CPBD
and
AMPLIFIER RACK
68-75

56-63

Dimmer circuit Dimmer circuit


Approx height 4800 Approx height 4800
UP 2040

2790
1830
7.102
STORE
2470 BALCONY 8.480
to THEATRE

Revisions: A 08/07/05 FIRST ISSUED w LIGHTING


ROBSON WARREN Architects Project: Drawing: Date: 11/07/2005

8 Northfields Prospect, Putney Bridge Rd ST. BRIDE FOUNDATION INSTITUTE ST BRIDE THEATRE Drawn by: SM
London SW18 1PE BRIDE LANE FLEET ST MEZZANINE Checked: PW
Telephone: 020-8871 9349 ROOM STUDIES Scale: 1:100
Facsimile: 020-8871 9489
LONDON EC4Y 8EQ ORIGINAL SCALE 1:100 at A3 Job No: 2201
0 1 2 3 4m
E-mail: robsonwarren@clara.co.uk FOR: THE GOVERNORS Dwg No: SK/11 Revision A

Das könnte Ihnen auch gefallen