WIRING DIAGRAM #1

STEPS IN CONNECTING ONE BULB CONTROLLED IN TWO LOCATION USING TWO THREE WAY SWITCHES

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W B

3. CONNECT THE T1 OF S3W A TO THE T1 OF S3W B

4. CONNECT THE T3 OF S3W A TO THE T3 OF S3W B

5. CONNECT THE TC OF S3W A TO THE L2

6. CHECK THE COUTINUTY OF THE CIRCUIT

7. TEST THE CIRCUIT

8. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #2
STEPS IN CONNECTING TWO BULBS CONTROLLED IN TWO LOCATION USING TWO THREE WAY SWITCHES

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W B

3. CONNECT THE T1 OF BULB B TO THE L1 OR WHERE T1 OF BULB A IS CONNECTED

4. CONNECT THE T2 OF BULB B TO THE TC OF S3W B OR WHERE T2 OF BULB A IS CONNECTED

5. CONNECT THE T1 OF S3W A TO THE T1 OF S3W B

6. CONNECT THE T3 OF S3W A TO THE T3 OF S3W B

7. CONNECT THE TC OF S3W A TO THE L2

8. CHECK THE COUTINUTY OF THE CIRCUIT

9. TEST THE CIRCUIT

10. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #3
STEPS IN CONNECTING BULB A IS CONTROLLED BY SWITCH A, BULB B AND C ARE CONTROLLED ALTERNATELY FROM
SWITCH B AND C USING TWO THREE WAY SWITCHES

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE T2 OF SPST

3. CONNECT THE T1 OF BULB B AND C TO THE L1 OR WHERE T1 OF BULB A IS CONNECTED

4. CONNECT THE T2 OF BULB B TO TC OF S3W B

5. CONNECT THE T2 OF BULB C TO TC OF S3W B OR WHERE T2 OF BULB B IS CONNECTED

6. CONNECT THE T1 OF S3W A TO T1 OF THE T1 OF THE S3W B

7. CONNECT THE T1 OF S3W A TO T3 OF THE T3 OF THE S3W B

8. CONNECT THE TC OF S3W A TO THE L2

9. CONNECT THE T2 OF SPST TO THE L2 OR WHERE TC OF S3W A IS CONNECTED

10. CHECK THE COUTINUTY OF THE CIRCUIT

11. TEST THE CIRCUIT

12. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #4
STEPS IN CONNECTING BULB A AND C ARE CONTROLLED ALTERNATELY OF SWITCH B AND C USING TWO
THREE WAY SWITCHES. BULB B AND D ARE CONTROLLED BY SWITCH A AND B USING S2 SWITCH

1. CONNECT THE T1 OF THE BULB A AND B TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W C

3. CONNECT THE T2 OF BULB B TO THE T2 OF SWITCH A OF S2

4. CONNECT THE T1 OF BULB C AND D TO THE L1 OR WHERE L1 OF BULB A AND B ARE CONNECTED

5. CONNECT THE T2 OF BULB C TO THE TC OF SEW C OR WHERE T2 OF BULB A IS CONNECTED

6. CONNECT THE T2 OF BULB D TO THE SWITCH B OF S2

7. CONNECT THE T1 OF S3W C TO THE T1 OF S3W D

8. CONNECT THE T3 OF S3W C TO THE T3 OF S3W D

9. CONNECT THE TC OF S3W C TO THE L2

10. CONNECT THE OF T2 OF S2 (SWITCH A AND B) TO THE L2 OR WHERE TC OF S3W C IS CONNECTED

11. CHECK THE COUTINUITY OF THE CIRCUIT

12. TEST THE CIRCUIT

13. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #5
STEPS IN CONNECTING TWO BULBS CONTROLLED ALTERNATELY FROM SWITCH A AND B USING TWO THREE
WAY SWITCHES WITH DUPLEX CONVINIENCE OUTLET

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W B

3. CONNECT THE T1 OF BULB B TO THE L1 OR WHERE T1 OF THE BULB A IS CONNECTED

4. CONNECT THE T2 OF BULB B TO THE TC OF S3W B OR WHERE T2 OF BULB A IS CONNECTED

5. CONNECT THE T1 OF S3W A TO THE T1 OF S3W B

6. CONNECT THE T3 OF S3W A TO THE T3 OF S3W B

7. CONNECT THE TC OF S3W A TO THE L2

8. CONNECT THE T1 OF CO TO L1 OR WHERE T1 OF BULB A AND B ARE CONNECTED

9. CONNECT THE T2 OF CO TO L2 OR WHERE TC OF S3W A IS CONNECTED

10. CHECK THE COUTINUITY OF THE CIRCUIT

11. TEST THE CIRCUIT

12. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #6
STEPS IN CONNECTING ONE BULB THAT CAN BE CONTROLLED FROM SWITCH B AND C IF THE SWITCH A IS
ON

1. CONNECT THE T1 OF BULB TO L1

2. CONNECT THE T2 OF BULB TO THE TC OF S3W B

3. CONNECT THE T1 OF S3W A TO THE T1 OF S3W B

4. CONNECT THE T3 OF S3W A TO THE T3 OF S3W B

5. CONNECT THE TC OF S3W A TO THE T2 OF SPST

6. CONNECT THE T1 OF SPST TO L2

7. CHECK THE COUTINUITY OF THE CIRCUIT

8. TEST THE CIRCUIT

9. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #7
STEPS IN CONNECTING BULB A AND C ARE CONTROLLED ALTERNATELY FROM SWITCH A AND B, BULB B IS
CONTROLLED BY SPST USING S2 SWITCH WITH TWO DUPLEX CONVENIENCE OUTLET

1. CONNECT THE T1 OF BULB A AND B TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W (B)

3. CONNECT THE T1 OF BULB B TO THE T2 OF SPST IN S2 SWITCH

4. CONNECT THE T2 OF BULB C TO THE L1 OR WHERE T1 OF BULB A AND B IS CONNECTED

5. CONNECT THE T2 OF BULB C TO THE TC OF S3W (B) OR WHERE T2 OF BULB A IS CONNECTED

6. CONNECT THE T1 OF S3W (A) TO THE T1 OF S3W (B)

7. CONNECT THE T3 OF S3W (A) TO THE T3 OF S3W (B)

8. CONNECT THE TC OF S3W (A) AND T1 OF SPST IN S2 TO L2

9. CONNECT THE T1 OF DCO (A) TO THE L1

10. CONNECT THE T2 OF DCO (A) TO THE L2

11. CONNECT THE T1 OF DCO (B) TO THE L1 OR WHERE T1 OF DCO (A) IS CONNECTED

12. CONNECT THE T2 OF DCO (B) TO THE L2 OR WHERE T2 OF DCO (A) IS CONNECTED

13. CHECK THE COUTINUITY OF THE CIRCUIT

14. TEST THE CIRCUIT

15. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #8
STEPS IN CONNECTING BULB A AND C ARE CONTROLLED FROM SWITCH A AND C IF THE SWITCH B IS ON,
BULB B IS INDICATOR LAMP THAT THE SWITCH B IS ON

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W (B)

3. CONNECT THE T1 OF BULB B TO THE L1 OR WHERE T1 OF BULB A IS CONNECTED

4. CONNECT THE T2 OF BULB B TO THE T2 OF SPST IN S2

5. CONNECT THE T1 OF BULB C TO THE L1 OR WHERE T1 OF BULB A AND B ARE CONNECTED

6. CONNECT THE T2 OF BULB C TO THE TC OF S3W (B) OR WHERE T2 OF BULB A IS CONNECTED

7. CONNECT THE T1 OF S3W (A) TO THE T1 OF S3W (B)

8. CONNECT THE T3 OF S3W (A) TO THE T3 OF S3W (B)

9. CONNECT THE TC OF S3W (A) TO T2 OF SPST OR WHERE T2 OF BULB B IS CONNECTED

10. CONNECT THE T2 OF SPST TO THE L2

11. CHECK THE COUTINUITY OF THE CIRCUIT

12. TEST THE CIRCUIT

13. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #9
STEPS IN CONNECTING TWO LAMP ANNUNCIATOR SYSTEM

1. CONNECT THE T1 OF BELL TO THE L1

2. CONNECT THE T2 OF BELL TO THE T1 OF BULB A

3. CONNECT THE T2 OF BULB A TO THE T2 OF PUSH BUTTON A

4. CONNECT THE T1 OF BULB B TO THE T1 OF BULB A OR WHERE T2 OF THE BELL IS CONNECTED

5. CONNECT THE T2 OF BULB B TO THE T2 OF PUSH BUTTON B

6. CONNECT THE T1 OF PUSH BUTTON A TO L2

7. CONNECT THE T1 OF PUSH BUTTON B TO L2 OR WHERE T1 OF PUSH BUTTON A IS CONNECTED

8. CHECK THE COUTINUITY OF THE CIRCUIT

9. TEST THE CIRCUIT

10. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #10
STEPS IN CONNECTING BULB B AND D ARE CONTROLLED FROM SWITCH B AND D WHILE BULB A AND C ARE
CONTROLLED BY SWITCH A AND C

1. CONNECT THE T1 OF BULB A AND B TO THE L1

2. CONNECT THE T2 OF BULB A TO THE T2 OF SPST (A)

3. CONNECT THE T2 OF BULB B TO THE TC OF S3W (B)

4. CONNECT THE T1 OF BULB C AND D TO THE L1 OR WHERE T1 OF BULB A AND B IS CONNECTED

5. CONNECT THE T2 OF BULB C TO THE T2 OF SPST (B)

6. CONNECT THE T1 OF BULB D TO THE TC OF S3W (B)

7. CONNECT THE T1 OF S3W A TO THE T1 OF S3W B

8. CONNECT THE T3 OF S3W A TO THE T3 OF S3W B

9. CONNECT THE T2 OF SPST A TO THE T2 OF SPST B OR WHERE T2 OF BULB A AND C IS CONNECTED

10. CONNECT THE T1 OF SPST A TO L1

11. CONNECT THE TC OF S3W A TO L1 OR WHERE T1 OF SPST A IS CONNECTED

12. CONNECT THE T1 OF SPST B TO L1 WHERE T1 OF SPST A AND TC OF S3W A IS CONNECTED

13. CHECK THE COUTINUITY OF THE CIRCUIT

14. TEST THE CIRCUIT

15. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #11
STEPS IN CONNECTING BELL, CHIME AND BUZZER ARE CONTROLLED INDIVIDUALLY BY PUSH BUTTON

1. CONNECT THE T1 OF BELL TO THE L1

2. CONNECT THE T2 OF BELL TO THE T2 OF PUSH BUTTON (A)

3. CONNECT THE T1 OF CHIME TO THE L1 OR WHERE T1 OF BELL IS CONNECTED

4. CONNECT THE T2 OF CHIME TO THE T2 OF PUSH BUTTON (B)

5. CONNECT THE T1 OF BUZZER TO THE L1 WHERE T1 OF BELL AND CHIME IS CONNECTED

6. CONNECT THE T2 OF BUZZER TO THE T2 OF PUSH BUTTON (C)

7. CONNECT THE T1 OF PUSH BUTTON (A) TO THE L2

8. CONNECT THE T1 OF PUSH BUTTON (B) TO THE L2 OR WHERE T1 OF PUSH BUTTON (A) IS CONNECTED

9. CONNECT THE T1 OF PUSH BUTTON (C) TO THE L2 OR WHERE T1 OF PUSH BUTTON (A) AND PUSH

BUTTON (B) ARE CONNECTED

10. CHECK THE COUTINUITY OF THE CIRCUIT

11. TEST THE CIRCUIT

12. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #12
STEPS IN CONNECTING BULB A AND C ARE CONTROLLED BY SWITCH B, BULB B IS CONTROLLED
ALTERNATELY FROM SWITCH A AND B WITH SPECIAL PURPOSE OUTLET

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE T2 OF SPST IN S2

3. CONNECT THE T1 OF BULB B AND C TO THE L1 OR WHERE T1 OF BULB A IS CONNECTED

4. CONNECT THE T2 OF BULB B TO THE TC OF S3W A

5. CONNECT THE T2 OF BULB C TO THE T2 OF SPST OR WHERE T2 OF BULB A IS CONNECTED

6. CONNECT THE T1 OF S3W A TO THE T1 OF S3W B

7. CONNECT THE T3 OF S3W A TO THE T3 OF S3W B

8. CONNECT THE TC OF S3W B AND T1 OF SPST IN S2 TO L2

9. CONNECT THE T1 OF SPO TO THE L1

10. CONNECT THE T2 OF SPO TO THE L2

11. CONNECT THE TERMINAL OF GROUND TO PANEL BOX

12. CHECK THE COUTINUITY OF THE CIRCUIT

13. TEST THE CIRCUIT

14. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #13
STEPS IN CONNECTING DOORBELL A CONTROLLED BY PUSH BUTTON B, DOORBELL B CONTROLLED BY
PUSH BOTTON B WITH DUPLEX CONVINIENCE OUTLET

1. CONNECT THE T1 OF DORBELL A TO THE L1

2. CONNECT THE T2 OF DORBELL A TO THE T2 OF PUSH BUTTON B

3. CONNECT THE T1 OF DORBELL B TO THE L1 OR WHERE T1 OF DOORBELL A IS CONNECTED

4. CONNECT THE T2 OF DORBELL B TO THE T2 OF PUSH BUTTON A

5. CONNECT THE T1 OF PUSH BUTTON A TO L1

6. CONNECT THE T1 OF PUSH BUTTON B TO L1 OR WHERE T1 OF PUSH BUTTON A IS CONNECTED

7. CONNECT THE T1 OF DCO TO L1 OR WHERE T1 OF DOORBELL A AND B ARE CONNECTED

8. CONNECT THE T2 OF DCO TO L2 OR WHERE T2 OF PUSH BUTTON A AND B ARE CONNECTED

9. CHECK THE COUTINUITY OF THE CIRCUIT

10. TEST THE CIRCUIT

11. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #14
STEPS IN CONNECTING ONE BULB THAT CAN BE CONTROLLED ALTERNATELY FROM SWICH A, B, AND C
USING TWO THREE WAY SWITCHES AND ONE FOUR WAY SWITCH

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W B

3. CONNECT THE T1 OF S3W B TO THE T2 OF S4W

4. CONNECT THE T3 OF S3W B TO THE T4 OF S4W

5. CONNECT THE T1 OF S3W A TO THE T1 OF S4W

6. CONNECT THE T3 OF S3W A TO THE T3 OF S4W

7. CONNECT THE TC OF S3W A TO L2

8. CHECK THE COUTINUITY OF THE CIRCUIT

9. TEST THE CIRCUIT

10. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #15
STEPS IN CONNECTING THREE PIN LIGHTS ARE CONTROLLED BY INDIVIDUAL SWITCH USING S3 SWITCH

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE T2 OF SPST (A) IN S3

3. CONNECT THE T1 OF BULB B TO THE L1 OR WHERE T1 OF THE BULB A IS CONNECTED

4. CONNECT THE T1 OF BULB B TO THE T2 OF SPST (B) IN S3

5. CONNECT THE T1 OF BULB C TO THE L1 OR WHERE T1 OF THE BULB A AND B ARE CONNECTED

6. CONNECT THE T2 OF BULB C TO THE T2 OF SPST (C) IN S3

7. CONNECT THE T2 OF SPST A, B, AND C, IN S3 TO THE L2

8. CHECK THE COUTINUITY OF THE CIRCUIT

9. TEST THE CIRCUIT

10. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #16
STEPS IN CONNECTING TWO BULBS CONTROLLED IN THREE LOCATION USING TWO THREE WAY SWITCHES
AND ONE FOUR WAY SWITCH

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W (B)

3. CONNECT THE T1 OF BULB B TO THE L1 OR WHERE T1 OF BULB A IS CONNECTED

4. CONNECT THE T2 OF BULB B TO THE TC OF S3W (B) OR WHERE T2 OF BULB A IS CONNECTED

5. CONNECT THE T1 OF S3W (B) TO THE T2 OF S4W

6. CONNECT THE T3 OF S3W (B) TO THE T4 OF S4W

7. CONNECT THE T1 OF S3W (A) TO THE T1 OF S4W

8. CONNECT THE T3 OF S3W (A) TO THE T3 OF S4W

9. CONNECT THE TC OF S3W (A) TO L2

10. CHECK THE COUTINUITY OF THE CIRCUIT

11. TEST THE CIRCUIT

12. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #17
STEPS IN CONNECTING BULB A AND C ARE CONTROLLED IN THREE LOCATION USING TWO THREE WAY
SWITCHES AND ONE FOUR WAY SWITCH AND BULB B IS CONTROLLED BY SPST WITH DUPLEX CONVIENINCE
OUTLET AND SPECIAL PURPOSE OUTLET

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W (B)

3. CONNECT THE T1 OF BULB B TO THE L1 OR WHERE T1 OF BULB A IS CONNECTED

4. CONNECT THE T2 OF BULB B TO THE T2 OF SPST IN S2

5. CONNECT THE T1 OF BULB C TO THE L1 OR WHERE T1 OF BULB A AND B ARE CONNECTED

6. CONNECT THE T2 OF BULB C TO THE TC OF S3W (B) OR WHERE T2 OF BULB A IS CONNECTED

7. CONNECT THE T1 OF S3W (A) TO THE T2 OF S4W

8. CONNECT THE T3 OF S3W (A) TO THE T4 OF S4W

9. CONNECT THE T1 OF S3W (B) TO THE T1 OF S4W

10. CONNECT THE T2 OF S3W (B) TO THE T3 OF S4W

11. CONNECT THE T2 OF SPST AND TC OF S3W (A) TO THE L2

12. CONNECT THE T1 OF DCO TO L1

13. CONNECT THE T2 OF DCO TO L2

14. CONNECT THE T1 OF SPO TO THE L1

15. CONNECT THE T2 OF SPO TO THE L2

16. CONNECT THE TERMINAL OF GROUND TO PANEL BOX

17. CHECK THE COUTINUITY OF THE CIRCUIT

18. TEST THE CIRCUIT

19. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #18
STEPS IN CONNECTING BULB A AND B ARE ALTERNATELY FROM SWITCH B AND C, BULB B IS CONTROLLED
BY SPST WITH SPECIAL PURPOSE OUTLET

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W (B)

3. CONNECT THE T1 OF BULB B AND C TO THE L1 OR WHERE T1 OF BULB A IS CONNECTED

4. CONNECT THE T2 OF BULB B TO THE TC OF S3W (B) OR WHERE T2 OF BULB A IS CONNECTED

5. CONNECT THE T2 OF BULB C TO THE T2 OF SPST

6. CONNECT THE T1 OF S3W (A) TO THE T1 OF S3W B

7. CONNECT THE T3 OF S3W (A) TO THE T3 OF S3W B

8. CONNECT THE TC OF S3W (A) TO L2

9. CONNECT THE T2 OF SPST TO L2 OR WHERE TC OF S3W (A) IS CONNECTED

10. CONNECT THE T1 OF SPO TO THE L1

11. CONNECT THE T2 OF SPO TO THE L2

12. CONNECT THE TERMINAL OF GROUND TO THE PANEL BOX

13. CHECK THE COUTINUITY OF THE CIRCUIT

14. TEST THE CIRCUIT

15. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #19
STEPS IN CONNECTING BULB A IS CONTROLLED IN THREE LOCATIONS USING TWO THREE WAY SWITCHES
AND ONE FOUR WAY SWITCH, BULB B IS CONTROLLED BY SPST

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W (B)

3. CONNECT THE T1 OF BULB B TO THE L1 OR WHERE T1 OF BULB A IS CONNECTED

4. CONNECT THE T2 OF BULB B TO THE T2 OF SPST IN S2

5. CONNECT THE T1 OF S3W (B) TO THE T2 OF S4W

6. CONNECT THE T3 OF S3W (B) TO THE T4 OF S4W

7. CONNECT THE T1 OF S3W (A) TO THE T1 OF S4W

8. CONNECT THE T2 OF S3W (A) TO THE T3 OF S4W

9. CONNECT THE TC OF S3W (A) AND T1 OF SPST IN S2 TO L2

10. CHECK THE COUTINUITY OF THE CIRCUIT

11. TEST THE CIRCUIT

12. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #20
STEPS IN CONNECTING ONE BULB CONTROLLED IN FOUR LOCATION USING TWO THREE WAY SWITCHES AND
TWO FOUR WAY SWITCHES

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W (B)

3. CONNECT THE T1 OF S3W (B) TO THE T2 OF S4W (B)

4. CONNECT THE T3 OF S3W (B) TO THE T2 OF S4W (B)

5. CONNECT THE T2 OF S3W (B) TO THE T2 OF S4W (A)

6. CONNECT THE T4 OF S3W (B) TO THE T4 OF S4W (A)

7. CONNECT THE T1 OF S3W (A) TO THE T1 OF S4W (A)

8. CONNECT THE T3 OF S3W (A) TO THE T3 OF S4W (A)

9. CONNECT THE TC OF S3W (A) TO L2

10. CHECK THE COUTINUITY OF THE CIRCUIT

11. TEST THE CIRCUIT

12. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #21
STEPS IN CONNECTING TWO BULB CONTROLLED IN FOUR LOCATION USING TWO THREE WAY SWITCHES AND
TWO FOUR WAY SWITCHES WITH DUPLEX CONVIENINCE OUTLET THAT CAN BE USED IF THE SWITCH A IS ON

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W (D)

3. CONNECT THE T1 OF S3W (D) TO THE T2 OF S4W (E)

4. CONNECT THE T3 OF S3W (D) TO THE T2 OF S4W (E)

5. CONNECT THE T2 OF S3W (E) TO THE T2 OF S4W (C)

6. CONNECT THE T4 OF S3W (E) TO THE T4 OF S4W (C)

7. CONNECT THE T1 OF S3W (B) TO THE T1 OF S4W (C)

8. CONNECT THE T3 OF S3W (B) TO THE T3 OF S4W (C)

9. CONNECT THE TC OF S3W (B) TO L2

10. CONNECT THE T1 OF SPST (A) TO L1

11. CONNECT THE T2 OF SPST (A) TO THE T2 OF DCO

12. CONNECT THE T2 OF DCO TO L2

13. CHECK THE COUTINUITY OF THE CIRCUIT

14. TEST THE CIRCUIT

15. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #22
STEPS IN CONNECTING TWO BULB CONTROLLED INDIVIDUALLY BY USING TWO THREE WAY SWITCHES AND
CONTROLLED BY ONE THREE WAY SWITCH AT THE SAME TIME IN ONE LOCATION

1. CONNECT THE T1 OF BULB A TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W (B)

3. CONNECT THE T1 OF S3W (B) TO THE T2 OF S4W (B)

4. CONNECT THE T3 OF S3W (B) TO THE T4 OF S4W (B)

5. CONNECT THE T2 OF S4W (B) TO THE T2 OF S4W (A)

6. CONNECT THE T4 OF S4W (B) TO THE T4 OF S4W (A)

7. CONNECT THE T1 OF S3W (A) TO THE T1 OF S4W (A)

8. CONNECT THE T3 OF S3W (A) TO THE T3 OF S4W (A)

9. CONNECT THE TC OF S3W TO L2

10. CONNECT THE T1 OF SPST TO L1

11. CONNECT THE T2 OF SPST TO THE T2 OF DCO

12. CONNECT THE T1 OF DCO TO L2

13. CHECK THE COUTINUITY OF THE CIRCUIT

14. TEST THE CIRCUIT

15. OBSERVE GOOD HOUSEKEEPING


WIRING DIAGRAM #23
STEPS IN CONNECTING BULB A AND C ARE CONTROLLED IN THREE LOCATION USING TWO THREE WAY
SWITCHES AND ONE FOUR WAY SWITCH AND BULB B AND D ARE CONTROLLED BY SPST IN S2 SWITCH WITH
DUPLEX CONVIENINCE OUTLET AND SPECIAL PURPOSE OUTLET

1. CONNECT THE T1 OF BULB A AND B TO THE L1

2. CONNECT THE T2 OF BULB A TO THE TC OF S3W (B)

3. CONNECT THE T2 OF BULB B TO THE T2 OF SPST IN S2 SWITCH

4. CONNECT THE T1 OF BULB C AND D TO THE L1 OR WHERE T1 OF BULB A AND B ARE CONNECTED

5. CONNECT THE T2 OF BULB C TO THE TC OF S3W (B) OR WHERE T2 OF BULB A IS CONNECTED

6. CONNECT THE T2 OF BULB D TO THE T2 OF SPST IN S2 OR WHERE T2 OF BULB B IS CONNECTED

7. CONNECT THE T1 OF S3W (B) TO THE T2 OF S4W

8. CONNECT THE T3 OF S3W (B) TO THE T4 OF S4W

9. CONNECT THE T1 OF S3W (A) TO THE T1 OF S4W

10. CONNECT THE T2 OF S3W (A) TO THE T3 OF S4W

11. CONNECT THE T2 OF SPST AND TC OF S3W (A) TO THE L2

12. CONNECT THE T1 OF DCO TO L1

13. CONNECT THE T2 OF DCO TO L2

14. CONNECT THE T1 OF SPO TO THE L1

15. CONNECT THE T2 OF SPO TO THE L2

16. CONNECT THE TERMINAL OF GROUND TO THE PANEL BOX

17. CHECK THE COUTINUITY OF THE CIRCUIT

18. TEST THE CIRCUIT

19. OBSERVE GOOD HOUSEKEEPING