Algorithm for short range fixed head hydrothermal scheduling using Classical method

Step1: Initial guess take the value of pik=pdk/M+N for both hydro and thermal
as pt1=pd1/M+N; ph1=pd1/M+N; pt2=pd2/M+N; ph2=pd2/M+N;and
lumbda0=2*a*pt1+b; than vj1=water conversion factor=(lumbda0/(2*x*ph1+y)).
Step2: Calculate lumbda1 and lumbda2 by using the initial guess vj1 value
lumbda1=2*((pd1+f)/(g));lumbda2=2*((pd2+f)/(g)).
Step3: Compute the values of pik as p11, p12, p21, p22 etc by given formulas
p11= ((lumbda1-b)/(2*a)); p21=((lumbda1-(y*vj1))/(2*x*vj1));
Step4: Calculate V=total volume utilization=6*(((x*p21)+y)*p21+z+
((x*p22)+y)*p22+z);
Step5: compute delV=V-v1 abs(delV)<=0.01 stop loop
Step6: Calculate total cost of operation