GE NuovoPignone - Electronically Approved Drawing - Checked: Garfagnini G.; Approved: Visintin F.

- Internal DT-'N'
COMPANY
DOCUMENT N° :
1046Z-00-DP-J-23K-GEI-000087

CONTRACTOR DOCUMENT N° : Page: 1 de 8

F10163 GEI INS DGM 000087 F 000 3


Document
Project Code Vendor Discipline
Type
Sequential N° Lang. Area: Rev

Vendor Logo & Name : PO Number: Vendor Document N° :

NUOVO PIGNONE SOM 5461126

SONATRACH

EXTRACTION DES LIQUIDES DES GAZ ASSOCIES HASSI


MESSAOUD ET SEPARATION D’HUILE LDHP ZCINA
ALGERIE

ENC 08 1046Z

Unit Control System & Power Supply Schematic


Contractor Return Code : Vendor Action :

 Reviewed without comments (1)  Reviewed with comments (2) New revision required : __

 Rejected (3)  Received for Information (4) At the latest on __/__/__ (dd/mm/yy)

Date : __/__/__ (dd/mm/yy) Name : ____________________  IFR  IFI  IFC  ASB

Signature :
Comments :

Rev Date Page Status Description Prepared by Checked by Approved by

3 21.05.13 8 FIN ISSUED FOR CONSTRUCTION CTQ . .

2 01.12.11 8 FIN ISSUED FOR CONSTRUCTION GARFAGNINI GIOVANARDI VISINTIN

1 21.09.10 6 FIN ISSUED FOR CONSTRUCTION GARFAGNINI GIOVANARDI VISINTIN

0 08.01.10 6 FIN ISSUED FOR CONSTRUCTION GARFAGNINI GIOVANARDI VISINTIN

D 22.11.09 6 COM ISSUED FOR REVIEW GARFAGNINI GIOVANARDI VISINTIN

C 30.09.09 6 COM ISSUED FOR REVIEW GARFAGNINI GIOVANARDI VISINTIN

B 24.07.09 6 COM ISSUED FOR REVIEW GARFAGNINI GIOVANARDI VISINTIN

A 20.03.09 6 COM ISSUED FOR REVIEW GARFAGNINI GIOVANARDI VISINTIN

7 REVISED see Revision Index Sh.2, AS BUILT WO 113984 CTQ El. Stored El. Stored 21/05/13
6 REVISED NETWORK ARCHITECTURE see Revision Index Sh.2 Baviera F. Garfagnini G. Visintin F. 01/12/11
5 French Translation Baviera F. 08/01/10
4 REVISED see Revision Indedx Sh.2 GG 08/01/10 JOB 1608994-97
3 REVISED see Revision Indedx Sh.2 GG 22/11/09 ITEM .
2 REVISED see Revision Indedx Sh.2 GG 30/09/09 TITLE N. SOM 5461126 /3
1 REVISED see Revision Indedx Sh.2 .
GG .
24/07/09 COVER SHEET LANGUAGE SHEET
0 ISSUE GG . . 20/03/09 A 1/2
REV DESCRIPTION PREP'D CHK'D APPR'D DATE © 2012 Nuovo Pignone S.r.l., all rights reserved REPLACES REPLACES REPLACED BY REPLACED
REVISION INDEX ACRONYMS LEGEND <1>

ADP Auxiliary Distribution Panel


SHEET TITLE 0 1 2 3 4 5 6 7
B/N Bently Nevada
1 COVER SHEET x x xx x xx x CMS Control Monitoring System
DCP Direct Current Panel
2 REV. INDEX, LEGEND AND GENERAL REMARKS x x x x x xx x F&G Fire & Gas
HMI Human Machine Interface
3 HARDWIRED CONFIGURATION x x x HS Hydraulic Starter
MCC Motor Control Center
4 NETWORKS STANDARD CONFIGURATION x x x x x PLC Programmable Logic Controller
UCS Unit Control System
5 LOAD SHARING AND MASTER CONTROL x x x UPS Unanteruptable Power Supply
SGS Safeguarding System
6 POWER SUPPLY DISTRIBUTION NETWORK x x x x x x SIL Safety Integrated Level

7 OVERALL NETWORK ARCHITECTURE x

8 IP NETWORK ADDRESSING TABLES x x

7 Revised index
Limits of Supply
6 Revised index
5 Revised index
4 Revised where shown <4> JOB 1608994-97
3 Revised where shown <3> ITEM
OTHERS GE OIL & GAS 2 Revised where shown <2> TITLE
CONTROL SYSTEM SCHEMATIC
N. SOM5461126 /3
1 Revised where shown <1> LANGUAGE SHEET
0 ISSUE REVISION INDEX, LEGEND AND GENERAL REMARKS A 2/3
REV DESCRIPTION © 2012 Nuovo Pignone S.r.l., all rights reserved REPLACES REPLACED BY
NOTES
1. ONE HYDRAULIC STARTING SYSTEM IS COMMON FOR TWO
GT UNITS. TWO HS ARE PROVIDED FOR ALL 4 GT UNITS. CUSTOMER CUSTOMER
2. AC MOTORS START/STOP, RUNNING SIGNALS, MCC STATUS
(REDUNDANT MODBUS TCP/IP) SEE SH.4 FOR DETAILS ELECTRICAL SUB-STATION EQUIPMENT CONTROL ROOM
3. CUSTOMER CMS PROVIDES 4-20mA REPETITONS OF PD
(DISCHARGE HEADER PRESSURE) & PS (SUCTION HEADER
PRESSURE) TO MKVI. <2> MCC
4. ONLY INSIDE UCP1 & 3. DCP
(Note 2)

CUSTOMER CUSTOMER
PLANT F&G
<1> CMS SGS

<2>

EXTERNAL TRIP REQUEST

TRIP NOTIFICATION
DC MOTORS START/STOP AND RUNNING SIGNALS,
DCP STATUS

<2> VENTILATION CUT-OUT


LUBE & SYNTHETIC OIL HEATER CUT-OUT <1>

CUMULATIVE FIRE & GAS TRIP NOTIFICATIONS LOCAL ESD P.B. UNIT CONTROL PANEL
TANK HEATER CUT-OUT

[UCP1]
MKVI SIMPLEX Load Sharing and Master Controler signals To/From Unit #2
FIRE & GAS SYSTEM
CUMULATIVE FIRE& GAS TRIP
TURBINE CONTROLLER Load Sharing and Master Controler signals To/From Unit #3
Load Sharing and Master Controler signals To/From Unit #4
[FGS1]
PERMISSIVES, FIRE ALARMS & TRIPS SEQUENCING, PROTECTION &
Commands To/From Unit #2
CONTROL LOGIC
Commands To/From Unit #1
COMMON ALARMS, OK STATUS, TRIP MULTIPLY CMD

MASTER LOAD SHARING VIBRATION COMMON TRIP SIGNALS


[TCP1] BN3590
VIBRATION
MONITORING
HYDRAULIC STARTER RACK
PLC [VIB1]

[HSS1]

HART
GG SPEED MULTIPLEXER
<2> REPEATER
PICK-UP to VIB.

(Note 4)
FIRE & GAS DETECTION SENSORS,

GEAR BOX VIB. PROBES (ACCEL.,


GT MAGNETIC SPEED PICK-UP’S

FUEL GAS SHUT-OFF VALVE &

ANALOG CONTROL SIGNALS

RADIAL, AXIAL) & KEY PHASOR

BEARING & TEMPERATURES


TEMPERATURES
CHAMBER FLAME DETECTION

AXIAL), KEY PHASORS & GAS


GT ENCLOSURE DP & COMB.

GT TEMPERATURES & GT
ANALOG INTERFACES

BEARING TEMPERATURES
FUEL GAS VENT VALVE
MANUAL DISCHARGE PB’s

& GT

GT VIB. PROBES (RADIAL,


DIGITAL INTERFACES

PROTECTION SIGNALS

GEN. ACCELEROMETER
ESD FIELD PB’S

PROTECTION SIGNALS

PROTECTION SIGNALS

SIGNALS
GEAR BOX BEARING
4-20mA CONTROL &

CE-CO VIB. PROBES

ANALOG CONTROL &


DIGITAL CONTROL &

DIGITAL CONTROL &


ESD FIELD PB’S

TEMPERATURES

PROTECTION SIGNALS
TEMPERATURES

CONTROL
PROTECTION &
SUCTION/DISCHARGE HEADER PRESSURE
GT BEARING

(RADIAL)
CE-CO

DIGITAL
<2>
GAS TURBINE GEAR BOX CE-CO PROCESS GAS
HYDRAULIC
STARTING SKID
(NOTE 1)
UNIT CONFIGURATION

Limits of supply JOB 1608994-97


ITEM

OTHERS GE O&G
2 Revised where shown <2> TITLE
CONTROL SYSTEM SCHEMATIC
N. SOM 5461126/3
1 Revised where shown <1> LANGUAGE SHEET
0 ISSUE HARDWIRED CONFIGURATION A 3/4
REV DESCRIPTION © 2012 Nuovo Pignone S.r.l., all rights reserved REPLACES REPLACED BY
Notes:
<2> <3> <2>
To other MKVI in
To Ethernet
UCP #2 #3 #4
1. “Redundant Modbus Master Switch in UCP#2
Direct Link” over Ethrnet from <6> CUSTOMER
MKVI to MCC. ELECTRICAL SUB-STATION
2.Displayed Data and Alarms on
Alarm Banner from:
CUSTOMER EQUIPMENT CONTROL ROOM
- MarkVI
- Bently Nevada Monitors MCC
3. Local Display for F&G is CPU
<1>
provided. UNIT CONTROL PANEL
4. Provided only inside UCP1 & 3.
5. Common for ALL GT Units [UCP1]
6. DCS Cables in customer scope
of supply
(8)
HYDRAULIC STARTER
PLC (5)
FIELD
[HSS1] (5)
(8)
PANEL
PC
(note 4) <2>
RS485/F.O. (3) LOCAL CONTROL
PANEL [LCP1]
Converters (3)

<1>(5) (3)
MarkVI SIMPLEX <1>
TURBINE CONTROLLER (5)
With Redundant Direct (5)
Modbus link
[TCP1] <2> (note 5) To Ethernet Switches
in UCP#2, #3, #4
(1) (5)
To Ethernet Switches (4)
(5) in UCP#2, #3, #4
ADH PDH UDH COPPER
TRUNKS
FIBER
TRUNKS
HMI <6> (4)

(5)
Network switch #1 [ESW1A] (4)
<3> <3>
(4)
<6>
(note 3) <3> ADH PDH UDH COPPER
TRUNKS
FIBER
TRUNKS
FIRE & GAS Remote Network switch #1 [ESWR1A]
(7) GAS CHROMATOGRAPH (4)
SYSTEM MONITORING SYSTEM (4)
(4)
[FGS1] [GC1]
(4) ADH PDH UDH COPPER
TRUNKS
FIBER
TRUNKS <6>
Remote Network switch #2 [ESWR1B]
(4)

DOT MATRIX PRINTER


Network switch #2 [ESW1B] [PRN1] (2)
35000/91
35000/22

COPPER FIBER
B/N VIBRATION ADH PDH UDH TRUNKS TRUNKS
MONITOR
[VIB1] HMI (1)
(note 6)

(6)
(1) (1)
(2) CMS
<1> (note 2) LOCAL HMI [HMIL1]
(2)

(2)
Links Legend:
(1) EGD (Ethernet Global Data) protocol over Ethernet (UDH) CUSTOMER DCS
(2) TCP/IP, SNMP, NTP over Ethernet (Copper Cable)
CUSTOMER CONTROL ROOM
(3) Modbus TCP/IP over Fiber Optics (in Customer Scope of Supply)
(4) Trunk Connection (PDH&UDH), over Ethernet Limits of supply 6 Revised where shown <6> JOB 040.2222
(5) Modbus Master over RS485
3 Revised where shown <3> ITEM
(6) Parallel connection
(7) Modbus over Ethernet TCP/IP OTHERS GE O&G
2 Revised where shown <2> TITLE N. SOM 5461126 /3
(8) “S90 Triplex” over Ethernet (PHD) 1 Revised where shown <1>
CONTROL SYSTEM SCHEMATIC LANGUAGE SHEET
0 ISSUE NETWORK TOPOLOGY FOR SINGLE UNIT A 4/5
REV DESCRIPTION © 2012 Nuovo Pignone S.r.l., all rights reserved REPLACES REPLACED BY
UCP1 UCP2 UCP3 UCP4
SPEED CONTROL, MKVI SPEED CONTROL, MKVI SPEED CONTROL, MKVI SPEED CONTROL, MKVI
ANTISURGE ANTISURGE ANTISURGE ANTISURGE

Flow Set Point Flow Set Point Flow Set Point Flow Set Point
Interface Control
Signals via EGD
From/To Unit1
Interface Control Interface Control
Interface Control
Signals via EGD Signals via EGD
Signals via EGD
MASTER PROCESS MASTER PROCESS MASTER PROCESS MASTER PROCESS
CONTROLLER CONTROLLER CONTROLLER CONTROLLER
& LOAD SHARING & LOAD SHARING & LOAD SHARING & LOAD SHARING

Interface Control Interface Control


Interface Control
Signals via EGD Signals via EGD
Signals via EGD
From/To Unit3 From/To Unit1 Interface Control
From/To Unit4
Interface Control Signals via EGD
Signals via EGD From/To Unit2
From/To Unit4

<2>
PS & PD

PS & PD

PS & PD

PS & PD

FT

PGT25
DLE 3BCL
CUSTOMER CMS (Note 1) UNIT 1
<1>

FT

PGT25
DLE 3BCL

UNIT 2
PS PS PS
PD PD PD

FT

PGT25
DLE 3BCL

Notes: UNIT 3
1. CUSTOMER CMS provides a 4-20mA signal repetition of PD (Discharge
Pressure of the common line) and PS (Suction Pressure of the common Limits of supply
line) by a MEDIAN voting logic to each MKVI.
FT

OTHERS GE O&G

PGT25
DLE 3BCL
POSSIBLE STATUS FOR “MASTER PROCESS CONTROLLER”
UCP1 UCP2 UCP3 UCP4 UNIT 4

AUTO TRACKING TRACKING TRACKING


TRACKING AUTO TRACKING TRACKING JOB 1608994-97
TRACKING TRACKING AUTO TRACKING ITEM

TRACKING TRACKING TRACKING AUTO 2 Revised where shown <2> TITLE N. SOM 5461126 /3
1 Revised where shown <1> CONTROL SYSTEM SCHEMATIC LANGUAGE SHEET
0 ISSUE LOAD SHARING & MASTER CONTROL A 5/6
REV DESCRIPTION © 2012 Nuovo Pignone S.r.l., all rights reserved REPLACES REPLACED BY
Notes:
1. All these items are only inside <1> <1> <3> <2>
UCP1 & 3.
110Vdc 230Vac – 50Hz 230Vac – 50Hz
2. Common for all GT Units. 230Vac – 50Hz
From DCP From UPS From UPS
From ADP
<6> Line A Line B
2kw
1.1Kw – 4 Hours <4> 5.4Kw – ½ Hours <3> 4.5Kw – 4 Hours
<2>
<2>
CUSTOMER EQUIPMENT CONTROL ROOM

UNIT CONTROL PANEL


<2> <1> [UCP1]
<2> <2> <1>
(note 1) <2>
(Spare 350W)
230Vac 230Vac 230Vac 230Vac 230Vac 230Vac
(Spare 350W)
230Vac DACA 24Vdc 24Vdc
24Vdc 24Vdc 24Vdc 24Vdc

110Vdc
<2> (note 2)

24 Vdc BUS GAS

24 Vdc SUPPLY LINE


<4> MKVI POWER
CHROMATOGRAPH
HMI INTERFACE
GAS CHROMAT. DISTRIBUTION
MODULE
<2> (PC, LCD)
POWER UNIT
0.1KW (110 Vdc) 400 W
(Spare 350W)

FIELD
<3> SOLENOIDS
LOCAL 100 W
CONTROL
PANEL
(PULSE JET)
1KW

HMI INTERFACE
LOCAL (PC, LCD, Printer, TURBINE FIRE & GAS
BN3500 Ethernet Ethernet SOLENOID HART N.6 N.6 N.1
CONTROL PANEL Eth Switches) CONTROL PANEL Detection Rack, Barriers
VERSAMAX HS PLC HS PLC Vibration Monitor Switch #1 Switch #2 & SHUT-OFF Multiplexer Internal Lighting Ventilation FAN Receptacle
(HMI PANEL PC) (MKVI) Alarm Annunciator
On Field Modules (RX3i #1) (RX3i #2) Panel/Horn 300 W
On CCR 1200 W 300 W 100 W 100 W 500 W 150 W 40 W each 40 W each 1000 W
150 W 100 W 100 W 100 W 800 W
900 W <6>
<3>

EARTH LEAKAGE CIRCUIT BREAKER

AUTOMATIC CIRCUIT BREAKER

Limits of supply
6 Revised where shown <6>
LOCKABLE ISOLATING SWITCH
4 Revised where shown <4> JOB 1608994-97
OTHERS GE O&G
3 Revised where shown <3> ITEM
DOOR LIMIT SWITCH 2 Revised where shown <2> TITLE N. SOM 5461126 /3
1 Revised where shown <1> CONTROL SYSTEM SCHEMATIC LANGUAGE SHEET
0 ISSUE POWER SUPPLY DISTRIBUTION NETWORK A 6/7
PLUG & SOCKET
REV DESCRIPTION © 2012 Nuovo Pignone S.r.l., all rights reserved REPLACES REPLACED BY
UNIT CONTROL PANEL UNIT CONTROL PANEL
[UCP1] [UCP3]

Local Network switch #1 [ESW1A] Local Network switch #2 [ESW1B] Local Network switch #1 [ESW3A] Local Network switch #2 [ESW3B]
COPPER FIBER COPPER FIBER
ADH PDH UDH TRUNKS TRUNKS ADH PDH UDH TRUNKS TRUNKS
FIBER
TRUNKS
COPPER
TRUNKS UDH PDH ADH FIBER
TRUNKS
COPPER
TRUNKS UDH PDH ADH

(3) (3)

UNIT CONTROL PANEL UNIT CONTROL PANEL


[UCP2] [UCP4]
(3) (3)

(1) Local Network switch #1 [ESW2A] Local Network switch #2 [ESW2B] Local Network switch #1 [ESW4A] Local Network switch #2 [ESW4B]
(2) (2) (1)
FIBER COPPER FIBER COPPER (2)
(1)
ADH PDH UDH COPPER
TRUNKS
FIBER
TRUNKS ADH PDH UDH COPPER
TRUNKS
FIBER
TRUNKS
TRUNKS TRUNKS UDH PDH ADH TRUNKS TRUNKS UDH PDH ADH (1)

(2)

(3) (3)

(3) (3)

(2)
(1)
(1) HMI (2)
(2) (1)
Redundant Remote Ethernet
HMI
Switches [EWSR1A,EWSR1B]
(1)
HMI LOCAL HMI [HMIL2] (2) HMI
(2) LOCAL HMI [HMIL4]
CMS
LOCAL HMI [HMIL1] LOCAL HMI [HMIL3]
(2) (2)
(2) (2)
(2) (2)
(2)
CUSTOMER DCS (note 1)

CUSTOMER CONTROL
ROOM

Links Legend:
Notes:
(1) EGD (Ethernet Global Data) protocol over Ethernet (UDH)
1. CUSTOMER CMS and relevant connecting cables are in customer scope
(2) TCP/IP, SNMP, NTP over Ethernet (PDH)
of supply
(3) Trunk Connection (PDH&UDH), over Ethernet
Limits of supply JOB 1608994-97
ITEM
OTHERS GE O&G TITLE N. SOM 5461126 /3
CONTROL SYSTEM SCHEMATIC LANGUAGE SHEET
6 ADDED Sh. OVERALL NETWORK ARCHITECTURE A 7/8
REV DESCRIPTION © 2012 Nuovo Pignone S.r.l., all rights reserved REPLACES REPLACED BY
TAG Description UDH PDH ADH Switch ESWnA Switch ESWnB
Location UCP Location UCP
TCP1 Turbine Control Panel 192.168.101.1Y1 NA NA
IP Address 192.168.201.22n IP Address 192.168.201.23n
VIB1 Vibration Monitor (3500/91) 192.168.101.1Y4 NA NA Ports DeviceTag Cable Type Subnet Ports Device Tag Cable Type Subnet
FGS1 Fire & Gas system NA 192.168.201.10Z NA Port_1 HMIL1 ( PDH main) CAT5 PDH Port_1 HMIL1 (PDH backup) CAT5 PDH
<7> Port_2 CAT5 PDH Port_2 CAT5 PDH
HMIL1 Human Machine Interface 192.168.101.00W 192.168.201.00W NA Port_3 CMS A CAT5 PDH Port_3 CMS B CAT5 PDH
ESW1A Local Ethernet Switch A NA 192.168.201.22n NA Port_4 HSS1 CAT5 PDH Port_4 CAT5 PDH
ESW1B Local Ethernet Switch B NA 192.168.201.23n NA Port_5 CAT5 PDH Port_5 F&G1 CAT5 PDH
Port_6 CAT5 PDH Port_6 CAT5 PDH
HSS1 Hydraulic Starter PLC NA 192.168.201.0Y9 NA Port_7 Port_7 CAT5 PDH
CAT5 PDH
LCP1 Local Control Panel NA 192.168.201.0Y7 NA Port_8 CAT5 PDH Port_8 CAT5 PDH
Port_9 HMIL1 (UDH main) CAT5 UDH Port_9 HMIL1 (UDH backup) CAT5 UDH
Table 1: UCP “y” Devices IP Addresses: Port_10 CAT5 UDH Port_10 TCP1 CAT5 UDH
(Y=1 W=4 Z=0), (Y=2 W=5 Z=1), (Y=3 W=6 Z=2), (Y=4 W=7 Z=3) <7> Port_11 CAT5 UDH Port_11 CAT5 UDH
Port_12 CAT5 UDH Port_12 VIB1 (3500/91) CAT5 UDH
Port_13 CAT5 UDH Port_13 CAT5 UDH
ESWR1A Remote Ethernet switch A NA 192.168.201.240 NA Port_14 CAT5 UDH Port_14 CAT5 UDH
Port_15 CAT5 UDH Port_15 CAT5 UDH
ESWR1B Remote Ethernet switch B NA 192.168.201.241 NA
Port_16 CAT5 UDH Port_16 CAT5 UDH
Table 2: REMOTE Ethernet Switches IP Addresses Port_17 CAT5 ADH Port_17 CAT5 ADH
Port_18 CAT5 ADH Port_18 CAT5 ADH
Port_19 CAT5 ADH Port_19 CAT5 ADH
Port_20 CrossOver Copper Trunk Port_20 CrossOver Copper Trunk
Port_21 Switch ESW1B CrossOver Copper Trunk Port_21 Switch ESW1A CrossOver Copper Trunk
IP Ethernet Address: 192.168.ABC.XYZ Port_22 Port_22
CrossOver Copper Trunk CrossOver Copper Trunk
Network A BC X Y Z Port_23 CrossOver Copper Trunk Port_23 Switch ESWR1B CrossOver Copper Trunk
Switch ESWR1A
Type Type Network Controller/Device Number Unit Number Type Of Device Port_24 CrossOver Copper Trunk Port_24 CrossOver Copper Trunk
Number Port_25 Fiber Optic Fiber Trunk Port_25 Fiber Optic Fiber Trunk
UDH 1 01-99 1 = Gas Turbine 1= Unit 1 1= R0 Port_26 LCP1 Fiber Optic Fiber Trunk Port_26 Fiber Optic Fiber Trunk
2= Steam Turbine 2= Unit 2 2 =S0 Table 3: Local Switch A Table 4: Local Switch B
. 3= T0 Switch ESWR1A Switch ESWR1B
. 4= VIB MON. Location CCR Location CCR
8= Unit 8 5= TEMP. MON. IP Address 192.168.201.240 IP Address 192.168.201.241
6= SIS R0 Ports DeviceTag Cable Type Subnet Ports Device Tag Cable Type Subnet
7= SIS S0 Port_1 CAT5 PDH Port_1 CAT5 PDH
8= SIS T0 Port_2 CAT5 PDH Port_2 CAT5 PDH
9= PLC Port_3 CAT5 PDH Port_3 CAT5 PDH
0 = Static Starter Port_4 CAT5 PDH Port_4 CAT5 PDH
0 = All other devices on UDH 1= Unit 1 1= Local Main HMI Port_5 CAT5 PDH Port_5 CAT5 PDH
2= Unit 2 2 =Local Backup HMI Port_6 CAT5 PDH Port_6 CAT5 PDH
Port_7 CAT5 PDH Port_7 CAT5 PDH
. 3= Historian
Port_8 CAT5 PDH Port_8 CAT5 PDH
. 4= OSM
5= Comm. Gateway A Port_9 CAT5 UDH Port_9 CAT5 UDH
8= Unit 8
Port_10 CAT5 UDH Port_10 CAT5 UDH
9=Remote (common to all 6= Comm. Gateway B
Port_11 CAT5 UDH Port_11 CAT5 UDH
units) 7= Remote HMI Port_12 CAT5 UDH Port_12 CAT5 UDH
8= F&G A (provision) Port_13 CAT5 UDH Port_13 CAT5 UDH
9= F&G B (provision) Port_14 CAT5 UDH Port_14 CAT5 UDH
0= NTP Port_15 CAT5 UDH Port_15 CAT5 UDH
PDH 2 01-54 2 to 100 reserved for GE supplied Note 1: Port_16 CAT5 UDH Port_16 CAT5 UDH
items such as Viewers and Printers Devices such as HMI Servers, Communication Port_17 CAT5 ADH Port_17 CAT5 ADH
Geteways, Port_18 CAT5 ADH Port_18 CAT5 ADH
20n with n from 1 to 49 are reserved Historian, Remote HMIs that are both on the UDH Port_19 CAT5 ADH Port_19 CAT5 ADH
for switches and PDH should use the same number for the last Port_20 Switch ESW1A CrossOver Copper Trunk Port_20 Switch ESW1B CrossOver Copper Trunk
octal in the IP address Port_21 Switch ESW2A CrossOver Copper Trunk Port_21 Switch ESW2B CrossOver Copper Trunk
25n with n from 1 to 4 are reserved Note 2: Port_22 Switch ESW3A CrossOver Copper Trunk Port_22 Switch ESW3B CrossOver Copper Trunk
for NTP servers Fire & Gas or Fire fighting protection devices when Port_23 Switch ESW4A CrossOver Copper Trunk Port_23 Switch ESW4B CrossOver Copper Trunk
on PDH Port_24 CrossOver Copper Trunk Port_24 CrossOver Copper Trunk
should have address 192.168.201.0Y8 (and 0Y9 for the Port_25 Fiber Optic Fiber Trunk Port_25 Fiber Optic Fiber Trunk
Port_26 Fiber Optic Fiber Trunk Port_26 Fiber Optic Fiber Trunk
redundant device)
Table 5: Remote Switch A Table 6: Remote Switch B
Table 7:Ethernet addressing rules JOB 1608994-97
ITEM
TITLE N. SOM 5461126 /3
7 Revised where shown <7>
CONTROL SYSTEM SCHEMATIC LANGUAGE SHEET
6 ADDED Sh. IP NETWORK ADDRESSING TABLES A 8/8
REV DESCRIPTION © 2012 Nuovo Pignone S.r.l., all rights reserved REPLACES REPLACED BY

Das könnte Ihnen auch gefallen