Sie sind auf Seite 1von 6

ADB3 DIRECTIONAL CONTROL SOLENOID VALVES CETOP 3

Technical sheet

AC votage, see AD3 serie 3 valves on ADB.3.E...Br.2


“Valves and Electronics” catalogue code P35030200. (PLASTIC COIL VARIANT)

Brevini Fluid Power S.p.A. - Via Moscova ,6 - 42124 Reggio Emilia (Italy)
Tel. +39 0522 270711 - Fax. +39 0522 270660
www.brevinifluidpower.com - info@brevinifluidpower.com
ADB.3.E...
DirEctionAl control vAlvEs cEtoP 3
The Brevini Fluid Power directional
Max. pressure ports P/A/B (1) 350 bar
control valves NG6 has been desi-
Max. pressure port T (DC voltage) (2) 160 bar
gned for subplate mounting with an
Max flow 60 l/min
interface in accordance with UNI ISO
Max excitation frequency 3 Hz
4401 - 03 - 02 - 0 - 94 standard (ex
Duty cycle 100% ED
CETOP R 35 H 4.2-4-03).
Fluid viscosity 10 ÷ 500 mm2/s
The use of solenoids with wet arma- Fluid temperature -25°C ÷ 75°C
tures allows a very practical, safe Ambient temperature -25°C ÷ 60°C
construction completely dispensing Max contamination level class 10 in accordance
with dynamic seals; the solenoid tube with NAS 1638 with filter ß25≥75
ADB.3.E...BR.2 is screwed directly onto the valve Weight with one DC solenoid 1,46 Kg
(Plastic coil variant) chest whilst the coil is kept in position Weight with two DC solenoids 2,02 Kg
by means of a lock nut. Weight with one DC plastic coil 1,35 Kg
ADB.3.E... Weight with two DC plastic coils 1,88 Kg
pressure drops page 3 The operation of the directional (1) Dynamic pressure allowed on P for 800.000 cycles.
valves is in electrical way. (2) Pressure dynamic allowed for 2 millions of cycles.
standard spools page 3
liMits oF use page 4 The centre position is obtained by means of calibrated length springs which reposition the spool
oVerall diMensions page 4 in the centre or end of travel position once the action of the impulse is over.
“a15” dc coil page 5 The solenoids are constructed with a protection class of IP65 to DIN 40050 standards and are
“Br” dc plastic coil Variant page 5 available in DC in different voltage. The solenoid coils are normally arranged for DIN 43650
standard connectors page 6 ISO 4400 type connectors.
The valves are designed for use with DIN 51524 standard hydraulic mineral oils and it is re-
commended that filters should be fitted to ensure a maximum contamination level of class 10
in accordance with NAS 1638, ß25≥75.
Into restrict outside ambient operating conditions, the plastic coils “BR” type variants are
suggested.

orDEring coDE
ADB ADB Directional valve

3 CETOP 3/NG6

E Electrical operator

** Spool (see tables next page)

* Mounting (table 1)

* Voltage (table 2)

** Variants:
00 = No variants
S1 = Solenoid without connectors
BR = DC plastc coil
(for No. 01/02/03/04/15/16 spools only)

2 Serial No.:
2 = for DC voltage (A15 coil)
(AC votage, see AD3 serie 3 valves on
“Valves and Electronics” catalogue code P35030200.)

tAB.1 - Mounting tAB.2 - voltAgEs


Dc coils
L 12V
C M 24V

File: ADB3E00$_E I• 2 04/2015/e


ADB.3.E... Directional control valves CETOP 3

Pressure drops

1 2 The diagram at the side shows the pressure Spool Connections


3 drop curves for spools during normal usage. type P→A P→B A→T B→T P→T
The fluid used is a mineral oil with a viscosity
4
of 46 mm2/s at 40 C°; the tests have been 01 5 5 5 5
5 carried out at a fluid temperature of 40 C°. For 02 6 6 6 6 5
higher flow rates than those in the diagram, 03 5 5 6 6
∆p (bar)

6
the losses will be those expressed by the 04 1 1 1 1 4
following formula: 11 4 6
∆p1 = ∆p x (Q1/Q)2 22 4 6
14 2 1 1 1 2
where ∆p will be the value for the losses for 28 1 2 1 1 2
a specific flow rate Q which can be obtained 17 1 3
from the diagram, ∆p1 will be the value of 15 4 4 6 6
Q (l/min) the losses for the flow rate Q1 that is used. 16 5 5 4 4
Curve No.

Standard Spool

Two solenoids, spring centred "C" Mounting One solenoid, side A "E" Mounting

Spool Covering Transient position Spool Covering Transient position
type type

01 + 01 +

02 - 02 -

03 + 03 +

04* - 04* -

22* + 15 -

11* + 16 +


14* - 17 +

28* - 14* -

28* -

One solenoid, side B "F" Mounting



Spool Covering Transient position
type
The tests have been carried out with solenoids at operating

temperature and a voltage 10% less than rated voltage with 01 +


a fluid temperature of 40°C. The fluid used was a mineral oil
with a viscosity of 46 mm2/s at 40°C. The values in the diagram 02 -
refers to tests carried out with the oil flow in two directions
simultaneously T = 2 bar (e.g.. from P to A and the same time 03 +
B to T). In the case where valves 4/2 and 4/3 were used
with the flow in one direction only, the limits of use could 04* -
have variations which may even be negative. Rest times:
the values are indicative and depend on following parameters: 15 -
hydraulic circuit, fluid used and variations in hydraulic scales
(pressure P, flow Q, temperature T). 16 +


17 +
Energizing 30 ÷ 50 ms.
De-energizing 60 ÷ 130 ms. 14* -

28* -

* price increasing

File: ADB3E00$_E I• 3 04/2015/e


ADB.3.E... Directional control valves CETOP 3

Limits of use
DC Standard solenoids BR Plastic coil Variant
1 7
5 4 Spool Solenoidi in DC
8 9
2 type Standard Var. BR
3
01 1 7
02 1 7
P (bar)

P (bar)
6 03 3 8
5 8
04 4 9 10
15 6 10
4 9
16 1 7
11-22 5 -
14-28 2 -
2-6
Curve
Q (l/min) Q (l/min)

Overall dimensions
BR variant
(DC Plastic coil)

E = Manual override

Support plane
specifications
Fixing screws UNI 5931 M5x30
with material specification min. 8.8
Tightening torque 5 ÷ 6 Nm / 0.5 ÷ 0.6 Kgm

File: ADB3E00$_E I• 4 04/2015/e


"A15" DC coils
Type of protection IP 65
Number of cycle 18.000/h
Supply tolerance ±10%
Ambient temperature -30°C ÷ 60°C
Duty cycle 100% ED
Insulation class wire H
Weight (coil) 0,354 Kg
Weight (solenoid) 0,526 Kg
Rated power 30W
Max. winding temperature (Ambient temperature at 20°C) 110°C
Resistance at 20°C for 12 voltage coil 4.8 Ohm (±10%)
Resistance at 20°C for 24 voltage coil 19.2 Ohm (±10%)

Gray (A) V86050004


Black (B) V86050002

Q25830024

Q25860036C
Tub M8333001 (lenght 83,5 mm) for nut
Nut M37050048 for tub code M83330001 code M37050048.
(lenght 83,5 mm). Q25860037

12V M14710001
24V M14710002

"A15" DC coils "BR" plastic variant


Type of protection IP 65
Number of cycle 18.000/h
Supply tolerance ±10%
Ambient temperature -54°C ÷ 60°C
Duty cycle 100% ED
Insulation class wire H
Weight (coil) 0,308 Kg
Weight (solenoid) 0,527 Kg
Rated power 33W
Max. winding temperature (Ambient temperature at 20°C) 110°C
Resistance at 20°C for 12 voltage coil 4.4 Ohm (±10%)
Resistance at 20°C for 24 voltage coil 17.5 Ohm (±10%)

Gray (A) V86050004


Black (B) V86050002

A ttention ! M ounting 2
O Ring between coil and nut Q25830024
Q25830028 Q25830101
Tub M8333001 (lenght 83,5 mm) for nut
code M37050048.
Nut M37050048 for tub code M83330001 Q25830101
(lenght 83,5 mm).

12V M14670001
24V M14670002

File: ADB3E00$_E I• 5 04/2015/e


connEctors DirEctionAl control vAlvEs
in AccorDAncE witH Din 43650 / iso 4400

connEctor tYPE orDEring coDE coDE

Grey (side A) Standard (IP65) V86.05.0004 No variant

Black (side B) Standard (IP65) V86.05.0002 No variant

© 2015 Brevini Fluid Power S.p.A. All rights reserved. Hydr-App, SAM Hydraulik, Aron, Brevini Hydraulics, BPE Electronics, VPS Brevini, OT Oiltechnology, logos are trademarks or are
registered trademarks of Brevini Fluid Power S.p.A. or other companies of the Brevini Group in Italy and other countries.
The technical features supplied in this catalogue are non binding and no legal action can be taken against such material. Brevini Fluid Power will not be held responsible for information
and specifications which may lead to error or incorrect interpretations. Given the continuous technical research aimed at improved technical features of our products, Brevini Fluid Power
reserves the right to make change that are considered appropriate without any prior notice. This catalogue cannot be reproduced (in while or in part) without the prior written consent of
Brevini Fluid Power. This catalogue supersedes all previous ones.
Use of the products in this catalogue must comply with the operating limits given in the technical specifications. The type of application and operating conditions must be assessed as
normal or in malfunction in order to avoid endangering the safety of people and/or items.
General terms and conditions of sale see website: www.brevinifluidpower.com.

File: ADB3E00$_E I• 6 04/2015/e