Gradation of GSB

Road Name : Date of Testing :


Package No : Test For :
Block : Grade of Concrete : M-
Location : Wt. of sample taken :

IS Sieve Wt. of Percentage Cumulative Cum. % of Percentage


sample of Wt. Percent of Wt. Wt. Passing Limits by Wt.
retained (gm) Retained (%) Retained (%) (%) Passing

Tested by Checked by

Flakiness & Elongation Index of Aggregate


Road Name : Date of Testing :
Package No : Test For :
Block : Material :
Location :
Total Wt. of Wt. of agg. Retained on Wt. of agg. Passing on Wt. of agg. Ret. On
Size of Aggregate Aggregate (gm) thickness gauge (gm) thickness gauge (gm) length gage after Ret. On
thickness gauge (gm)
Passing through Retained on
I.S. Sieve (mm). I.S. Sieve
(mm)
63 50
50 40
40 31.5
31.5 25
25 20
20 16
16 12.5
12.5 10
10 6.3

Combined Flakiness and Elongation indices = (C/A*100+D/B*100) =


Maximum Permissible Limit = 30%

Tested by Checked by

Aggregate Impact Value of Aggregate

Road Name : Date of Testing :


Package No : Test For :
Block : Material :
Location : Wt. of sample taken :

Test Nos. Average


Observation 1 2 3
Weight of aggregate sample filling in the
cylinder = W1 (gm)
Weight of aggregate passing 2.36 mm.
sieve after the test = W2 (gm)
A.I.V. = (W2/W1) x 100

Permissible Limit ……………… Maximum……………….%

Tested by Checked by

Water Absorption of Aggregate

Road Name : Date of Testing :


Package No : Test For :
Block : Material :
Location : Wt. sample taken :

Test Nos. Average


Observation 1 2 3
Wt/ of saturated surface dry aggregate in air (W1) gm.
Wt. of oven dried aggregate in air (W2) gm
Water absorption = (W1-W2) x 100/W2 (%)
Mean value of water absorption =

Tested by Checked by

Gradation of Course Aggregate

Road Name : Date of Testing :


Package No : Test For :
Block : Grade of Concrete : M-
Location : Wt. of sample taken :
IS Sieve Wt. retained Percentage of Wt. Cumulative Percent Cum. % of Percentage Limits by Wt. Passing
(gm) Retained (%) of Wt. Retained (%) Wt. Passing 40mm. 20mm. 12.5mm.
(%)
63 mm. 100
40 mm. 95-100 100
20 mm. 30-70 95-100 100
12.5 mm. 90-100
10 10-35 25-55 40-85
4.75 0-5 0-10 0-10

Tested by Checked by

Gradation of G-II Material

Road Name/Section Details : Date of Testing :


Package No : Wt. of sample taken : gm

IS Sieve Wt. of sample Percentage of Wt. Cumulative Percent Percent of Wt. Permissible
retained (gm) Retained (%) of Wt. Retained (%) Passing (%) Value
90 mm. 100
63 mm. 90-100
53 mm. 25-75
45 mm. 0-15
22.4mm. 0-5

Tested by Checked by

Gradation of G-III Material

Road Name : Date of Testing :


Package No :
Location : Wt. of sample taken :

IS Sieve Wt. of sample Percentage of Wt. Cumulative Percent Percent of Wt. Standard Limits
retained (gm) Retained (%) of Wt. Retained (%) Passing
63 mm. 100
53 mm. 95-100
45 mm. 65-90
22.4 mm. 0-10
11.2mm. 0-5
Tested by Checked by

Gradation of G.S.B Material

Road Name : Date of Testing :


Package No :
Location : Wt. of sample taken :

IS Sieve Wt. of sample Percentage of Wt. Cumulative Percent Percent of Wt. Standard Limits
retained (gm) Retained (%) of Wt. Retained (%) Passing
26.5mm. 100
4.75mm. 25-45
75  <10
Tested by Checked by

Gradation of G-II Material

Road Name : Date of Testing :


Package No :
Location : Wt. of sample taken :

IS Sieve Wt. of sample Percentage of Wt. Cumulative Percent Percent of Wt. Standard Limits
retained (gm) Retained (%) of Wt. Retained (%) Passing
90 mm. 100
63 mm. 90-100
53 mm. 25-75
45 mm. 0-15
22.4mm. 0-5

Tested by Checked by
Gradation of G-III Material

Road Name : Date of Testing :


Package No :
Location : Wt. of sample taken :

IS Sieve Wt. of sample Percentage of Wt. Cumulative Percent Percent of Wt. Standard Limits
retained (gm) Retained (%) of Wt. Retained (%) Passing
63 mm. 100
53 mm. 95-100
45 mm. 65-90
22.4 mm. 0-10
11.2mm. 0-5

Tested by Checked by
Gradation of Course Aggregate

Road Name : Date of Testing :


Package No : Test For :
Block : Grade of Concrete : M-
Location : Wt. of sample taken :

IS Sieve Wt. of Percentage Cumulative Cum. % of Percentage


sample of Wt. Percent of Wt. Wt. Passing Limits by Wt.
retained (gm) Retained (%) Retained (%) (%) Passing
40 mm. 95-100
20 mm. 30-70
10 mm. 10-35
4.75 mm. 0-5

Tested by Checked by
Gradation of Course Aggregate

Road Name : Date of Testing :


Package No : Test For :
Block : Grade of Concrete : M-
Location : Wt. of sample taken :

IS Sieve Wt. of sample Percentage of Cumulative Percent Cum. % of Wt. Percentage Limits
retained (gm) Wt. Retained (%) of Wt. Retained (%) Passing (%) by Wt. Passing
40 mm.
20 mm.
10 mm.
4.75 mm.
Pan

Tested by Checked by
Gradation of Course Aggregate (12.5mm)

Road Name : Date of Testing :


Package No : Test For :
Block : Grade of Concrete : M-
Location : Wt. of sample taken :

IS Sieve Wt. of Percentage Cumulative Cum. % of Percentage


sample of Wt. Percent of Wt. Wt. Passing Limits by Wt.
retained (gm) Retained (%) Retained (%) (%) Passing
20 mm. 100
12.5 mm. 90-100
10 mm. 40-85
4.75 mm. 0-10

Tested by Checked by
Gradation of Sand

Road Name : Date of Testing :


Package No :
Location : Wt. of sample taken :

IS Sieve Wt. of sample Percentage of Wt. Cumulative Percent Percent of Wt. Standard Limits
retained (gm) Retained (%) of Wt. Retained (%) Passing
10mm. 100
4.75 mm. 90-100
2.36 mm. 75-100
1.18mm. 55-90
600 mic. 35-59
300 mic. 8-30
150 mic. 0-10

Tested by Checked by

Flakiness Index of Aggregate

Road Name : Date of Testing :


Package No : Test For :
Block : Material :
Location :
Wt. of the fraction Thickness gauge size, Wt. of agg. Ret. On
Size of Aggregate
Passing through Retained on consisting of at last 200 (0.6 time the mean length gage after Ret. On

I.S. Sieve (mm). I.S. Sieve places (gm) sieve) (mm) thickness gauge (gm)

(mm)
63 50 W1 = 23.90 W1 =
50 40 W2 = 27.00 W2 =
40 31.5 W3 = 19.50 W3 =
31.5 25 W4 = 16.95 W4 =
25 20 W5 = 13.50 W5 =
20 16 W6 = 10.80 W6 =
16 12.5 W7 = 8.55 W7 =
12.5 10 W8 = 6.75 W8 =
10 6.3 W9 = 4.89 W9 =
Total w w

Flakiness Index = w/W x 100 = (%)

Layer Value Permissible Limit Where confirms to Prescribed Limit (Yes/No.)


30%
If Results don’t conform to the prescribed Limits, non conformance Report will be issued by the
PIU. The reference of the page No. of the register on which Non Conformance Reports copy
Preserved.

Tested by Checked by

Das könnte Ihnen auch gefallen