2. Customized Pipe MTO is modified from standard available MTO (file attached) but
a. Even with blank zone , QTY 4 is indicated. this occurs even if zone is not empty.
Before
After
b. We want to remove suffix mm and want to prefix DN, so pipe sizes will be shown as DN 500 instead
of 500mm.
-Use real value as shown in the picture(It will remove “mm”)
c. In simple report, ispec iparam[2] were used to report insulation spec and Insulation thickness.
Please guide how to add same in Report
-For insulation spec use ISPE or ISPR
-For Insu Thickness use INTH
d. Please guide how to add surface area (both internal / external for Paint calculation)
Use BRIARE & BREARE pseudo attributes to get Surface Area values.
Kindly study Surface Treatment Utility before applying the values. Help(F1) contains all the information
related to this topic.