Sie sind auf Seite 1von 10

ENGINEERING, INSPECTION AND TESTING

Jl Selumar 219 Beringin Indah, Pekanbaru


Phone: 628992672379 email: aaronenergi@yahoo.com

LIST OF LIFTING PAD EYE EQUIPMENT RIG ACS #10


CUSTOMER : PT ASRINDO CITRASENI SATRIA REPORT No. : AON/LGI/01
DATE OF EXAM. : 09 AUGUST 2017 WORK LOCATION : MINAS -5B#18
DESCRIPTION : PAD EYE OF FIRE EXTINGUISER
MATERIAL : CARBON STEEL

PROCEDURE ACCEPTANCE CRITERIA TYPE OF CURRENT MPI EQUIPMENT


ASME V Sec. 7 AWS D1.1 DC AC Yoke
ASTM E 709 AC Permanent Magnet Yoke
Permanent Magnet Prod
METHOD EXAM. PREPARATION TECHNIQUE
Dry Grinding Yoke S/N : Magnaflux 0855
Wet Machining Magnetic Particle : Magnaflux 7HF
Contrast B/W Wire Brush Contrast : Magnaflux WCP 2
Blasting Inspection Area : As per Drawing
Temperature : Ambient
S/N: 18 AE

INSPECTION RESULT COMMENT


FOUND CRACK ON WELDING IN PAD EYE
REJECTED

INSPECTED BY CLIENT
NDT MT/PT Lev. 2 PT ASRINDO CITRASENI SATRIA

S ANDRIYANTO RONNY P

FORM RIG-MPI/AE/2016/Aaron/Rev. 3
ENGINEERING, INSPECTION AND TESTING
Jl Selumar 219 Beringin Indah, Pekanbaru
Phone: 628992672379 email: aaronenergi@yahoo.com

LIST OF LIFTING PAD EYE EQUIPMENT RIG ACS #10


CUSTOMER : PT ASRINDO CITRASENI SATRIA REPORT No. : AON/LGI/02
DATE OF EXAM. : 09 AUGUST 2017 WORK LOCATION : MINAS -5B#18
DESCRIPTION : PAD EYE OF BLOWER 1
MATERIAL : CARBON STEEL

PROCEDURE ACCEPTANCE CRITERIA TYPE OF CURRENT MPI EQUIPMENT


ASME V Sec. 7 AWS D1.1 DC AC Yoke
ASTM E 709 AC Permanent Magnet Yoke
Permanent Magnet Prod
METHOD EXAM. PREPARATION TECHNIQUE
Dry Grinding Yoke S/N : Magnaflux 0855
Wet Machining Magnetic Particle : Magnaflux 7HF
Contrast B/W Wire Brush Contrast : Magnaflux WCP 2
Blasting Inspection Area : As per Drawing
Temperature : Ambient
S/N: 11 AE

INSPECTION RESULT COMMENT


ABOVE PART WERE INSPECTED NO RELEVANT INDICATION AT TIME
ACCEPTABLE INSPECTION

INSPECTED BY CLIENT
NDT MT/PT Lev. 2 PT ASRINDO CITRASENI SATRIA

S ANDRIYANTO RONNY P

FORM RIG-MPI/AE/2016/Aaron/Rev. 3
ENGINEERING, INSPECTION AND TESTING
Jl Selumar 219 Beringin Indah, Pekanbaru
Phone: 628992672379 email: aaronenergi@yahoo.com

LIST OF LIFTING PAD EYE EQUIPMENT RIG ACS #10


CUSTOMER : PT ASRINDO CITRASENI SATRIA REPORT No. : AON/LGI/03
DATE OF EXAM. : 09 AUGUST 2017 WORK LOCATION : MINAS -5B#18
DESCRIPTION : PAD EYE OF STAIR WAY TO WPF 2
MATERIAL : CARBON STEEL

PROCEDURE ACCEPTANCE CRITERIA TYPE OF CURRENT MPI EQUIPMENT


ASME V Sec. 7 AWS D1.1 DC AC Yoke
ASTM E 709 AC Permanent Magnet Yoke
Permanent Magnet Prod
METHOD EXAM. PREPARATION TECHNIQUE
Dry Grinding Yoke S/N : Magnaflux 0855
Wet Machining Magnetic Particle : Magnaflux 7HF
Contrast B/W Wire Brush Contrast : Magnaflux WCP 2
Blasting Inspection Area : As per Drawing
Temperature : Ambient
S/N: 3 AE

INSPECTION RESULT COMMENT


ABOVE PART WERE INSPECTED NO RELEVANT INDICATION AT TIME
ACCEPTABLE INSPECTION

INSPECTED BY CLIENT
NDT MT/PT Lev. 2 PT ASRINDO CITRASENI SATRIA

S ANDRIYANTO RONNY P

FORM RIG-MPI/AE/2016/Aaron/Rev. 3
ENGINEERING, INSPECTION AND TESTING
Jl Selumar 219 Beringin Indah, Pekanbaru
Phone: 628992672379 email: aaronenergi@yahoo.com

LIST OF LIFTING PAD EYE EQUIPMENT RIG ACS #10


CUSTOMER : PT ASRINDO CITRASENI SATRIA REPORT No. : AON/LGI/04
DATE OF EXAM. : 09 AUGUST 2017 WORK LOCATION : MINAS -5B#18
DESCRIPTION : PAD EYE OF CHOKE MANIFOLD
MATERIAL : CARBON STEEL

PROCEDURE ACCEPTANCE CRITERIA TYPE OF CURRENT MPI EQUIPMENT


ASME V Sec. 7 AWS D1.1 DC AC Yoke
ASTM E 709 AC Permanent Magnet Yoke
Permanent Magnet Prod
METHOD EXAM. PREPARATION TECHNIQUE
Dry Grinding Yoke S/N : Magnaflux 0855
Wet Machining Magnetic Particle : Magnaflux 7HF
Contrast B/W Wire Brush Contrast : Magnaflux WCP 2
Blasting Inspection Area : As per Drawing
Temperature : Ambient
S/N: 7 AE

INSPECTION RESULT COMMENT


ABOVE PART WERE INSPECTED NO RELEVANT INDICATION AT TIME
ACCEPTABLE INSPECTION

INSPECTED BY CLIENT
NDT MT/PT Lev. 2 PT ASRINDO CITRASENI SATRIA

S ANDRIYANTO RONNY P

FORM RIG-MPI/AE/2016/Aaron/Rev. 3
ENGINEERING, INSPECTION AND TESTING
Jl Selumar 219 Beringin Indah, Pekanbaru
Phone: 628992672379 email: aaronenergi@yahoo.com

LIST OF LIFTING PAD EYE EQUIPMENT RIG ACS #10


CUSTOMER : PT ASRINDO CITRASENI SATRIA REPORT No. : AON/LGI/05
DATE OF EXAM. : 09 AUGUST 2017 WORK LOCATION : MINAS -5B#18
DESCRIPTION : PAD EYE OF STAIR WAY TO WPF 1
MATERIAL : CARBON STEEL

PROCEDURE ACCEPTANCE CRITERIA TYPE OF CURRENT MPI EQUIPMENT


ASME V Sec. 7 AWS D1.1 DC AC Yoke
ASTM E 709 AC Permanent Magnet Yoke
Permanent Magnet Prod
METHOD EXAM. PREPARATION TECHNIQUE
Dry Grinding Yoke S/N : Magnaflux 0855
Wet Machining Magnetic Particle : Magnaflux 7HF
Contrast B/W Wire Brush Contrast : Magnaflux WCP 2
Blasting Inspection Area : As per Drawing
Temperature : Ambient
S/N: 2 AE

INSPECTION RESULT COMMENT


ABOVE PART WERE INSPECTED NO RELEVANT INDICATION AT TIME
ACCEPTABLE INSPECTION

INSPECTED BY CLIENT
NDT MT/PT Lev. 2 PT ASRINDO CITRASENI SATRIA

S ANDRIYANTO RONNY P

FORM RIG-MPI/AE/2016/Aaron/Rev. 3
ENGINEERING, INSPECTION AND TESTING
Jl Selumar 219 Beringin Indah, Pekanbaru
Phone: 628992672379 email: aaronenergi@yahoo.com

LIST OF LIFTING PAD EYE EQUIPMENT RIG ACS #10


CUSTOMER : PT ASRINDO CITRASENI SATRIA REPORT No. : AON/LGI/06
DATE OF EXAM. : 09 AUGUST 2017 WORK LOCATION : MINAS -5B#18
DESCRIPTION : PAD EYE OF STAIR WAY RIG CARRIER
MATERIAL : CARBON STEEL

PROCEDURE ACCEPTANCE CRITERIA TYPE OF CURRENT MPI EQUIPMENT


ASME V Sec. 7 AWS D1.1 DC AC Yoke
ASTM E 709 AC Permanent Magnet Yoke
Permanent Magnet Prod
METHOD EXAM. PREPARATION TECHNIQUE
Dry Grinding Yoke S/N : Magnaflux 0855
Wet Machining Magnetic Particle : Magnaflux 7HF
Contrast B/W Wire Brush Contrast : Magnaflux WCP 2
Blasting Inspection Area : As per Drawing
Temperature : Ambient
S/N: 12 AE

INSPECTION RESULT COMMENT


ABOVE PART WERE INSPECTED NO RELEVANT INDICATION AT TIME
ACCEPTABLE INSPECTION

INSPECTED BY CLIENT
NDT MT/PT Lev. 2 PT ASRINDO CITRASENI SATRIA

S ANDRIYANTO RONNY P

FORM RIG-MPI/AE/2016/Aaron/Rev. 3
ENGINEERING, INSPECTION AND TESTING
Jl Selumar 219 Beringin Indah, Pekanbaru
Phone: 628992672379 email: aaronenergi@yahoo.com

LIST OF LIFTING PAD EYE EQUIPMENT RIG ACS #10


CUSTOMER : PT ASRINDO CITRASENI SATRIA REPORT No. : AON/LGI/07
DATE OF EXAM. : 09 AUGUST 2017 WORK LOCATION : MINAS -5B#18
DESCRIPTION : PAD EYE OF STAIR WAY TO DRILLING CONSULE
MATERIAL : CARBON STEEL

PROCEDURE ACCEPTANCE CRITERIA TYPE OF CURRENT MPI EQUIPMENT


ASME V Sec. 7 AWS D1.1 DC AC Yoke
ASTM E 709 AC Permanent Magnet Yoke
Permanent Magnet Prod
METHOD EXAM. PREPARATION TECHNIQUE
Dry Grinding Yoke S/N : Magnaflux 0855
Wet Machining Magnetic Particle : Magnaflux 7HF
Contrast B/W Wire Brush Contrast : Magnaflux WCP 2
Blasting Inspection Area : As per Drawing
Temperature : Ambient
S/N: 13 AE

INSPECTION RESULT COMMENT


ABOVE PART WERE INSPECTED NO RELEVANT INDICATION AT TIME
ACCEPTABLE INSPECTION

INSPECTED BY CLIENT
NDT MT/PT Lev. 2 PT ASRINDO CITRASENI SATRIA

S ANDRIYANTO RONNY P

FORM RIG-MPI/AE/2016/Aaron/Rev. 3
ENGINEERING, INSPECTION AND TESTING
Jl Selumar 219 Beringin Indah, Pekanbaru
Phone: 628992672379 email: aaronenergi@yahoo.com

LIST OF LIFTING PAD EYE EQUIPMENT RIG ACS #10


CUSTOMER : PT ASRINDO CITRASENI SATRIA REPORT No. : AON/LGI/08
DATE OF EXAM. : 09 AUGUST 2017 WORK LOCATION : MINAS -5B#18
DESCRIPTION : PAD EYE OF ACCES CONTROL
MATERIAL : CARBON STEEL

PROCEDURE ACCEPTANCE CRITERIA TYPE OF CURRENT MPI EQUIPMENT


ASME V Sec. 7 AWS D1.1 DC AC Yoke
ASTM E 709 AC Permanent Magnet Yoke
Permanent Magnet Prod
METHOD EXAM. PREPARATION TECHNIQUE
Dry Grinding Yoke S/N : Magnaflux 0855
Wet Machining Magnetic Particle : Magnaflux 7HF
Contrast B/W Wire Brush Contrast : Magnaflux WCP 2
Blasting Inspection Area : As per Drawing
Temperature : Ambient
S/N: 010

INSPECTION RESULT COMMENT


ABOVE PART WERE INSPECTED NO RELEVANT INDICATION AT TIME
ACCEPTABLE INSPECTION

INSPECTED BY CLIENT
NDT MT/PT Lev. 2 PT ASRINDO CITRASENI SATRIA

S ANDRIYANTO RONNY P

FORM RIG-MPI/AE/2016/Aaron/Rev. 3
ENGINEERING, INSPECTION AND TESTING
Jl Selumar 219 Beringin Indah, Pekanbaru
Phone: 628992672379 email: aaronenergi@yahoo.com

LIST OF LIFTING PAD EYE EQUIPMENT - PORTABLE TOILET


CUSTOMER : PT ARDIAN PRATAMA PERKASA REPORT No. : AON/LGI/09
DATE OF EXAM. : 09 AUGUST 2017 WORK LOCATION : MINAS 5B#18 (ACS 10)
DESCRIPTION : PAD EYE OF PORTABLE TOILET
MATERIAL : CARBON STEEL

PROCEDURE ACCEPTANCE CRITERIA TYPE OF CURRENT MPI EQUIPMENT


ASME V Sec. 7 AWS D1.1 DC AC Yoke
ASTM E 709 AC Permanent Magnet Yoke
Permanent Magnet Prod
METHOD EXAM. PREPARATION TECHNIQUE
Dry Grinding Yoke S/N : Magnaflux 0855
Wet Machining Magnetic Particle : Magnaflux 7HF
Contrast B/W Wire Brush Contrast : Magnaflux WCP 2
Blasting Inspection Area : As per Drawing
Temperature : Ambient
S/N: 23

INSPECTION RESULT COMMENT


ABOVE PART WERE INSPECTED NO RELEVANT INDICATION AT TIME
ACCEPTABLE INSPECTION

INSPECTED BY CLIENT
NDT MT/PT Lev. 2 PT ARDIAN PRATAMA PERKASA

S ANDRIYANTO ERFIN T / ZAINIL

FORM RIG-MPI/AE/2016/Aaron/Rev. 3
ENGINEERING, INSPECTION AND TESTING
Jl Selumar 219 Beringin Indah, Pekanbaru
Phone: 628992672379 email: aaronenergi@yahoo.com

LIST OF LIFTING PAD EYE EQUIPMENT RIG ACS #10


NO DESCRIPTION REPORT No. CONDITION
1 FIRE EXTINGUSHER AON/LGI/01 ACCEPTED
2 BUG BLOWER 1 AON/LGI/02 ACCEPTED
3 STAIRWAY TO WPF 2 AON/LGI/03 ACCEPTED
4 CHOKE MANIFOLD AON/LGI/04 ACCEPTED
5 STAIRWAY TO WPF 1 AON/LGI/05 ACCEPTED
6 STAIRWAY TO RIG CARRIER AON/LGI/06 ACCEPTED
7 STAIR WAY TO CONSULE AON/LGI/07 ACCEPTED
8 ACCES CONTROL AON/LGI/08 ACCEPTED
9 PORTABLE TOILET AON/LGI/09 ACCEPTED

INSPECTED BY
NDT MT/PT Lev. 2

S ANDRIYANTO

FORM RIG-MPI/AE/2016/Aaron/Rev. 3