FINAL TEST REPORT.

Product:PV grid tie inverter Model: Solis-25k


Standard:IEC61727 S/N:110460191240001
NO Test result
Test parts Test item Limit Test data
. (P/F)
2120Vdc
(PV/Grid) to Ground
1 Hi-pot test NA P
4240Vdc
Safety test
(PV/Grid) to RS485
2 Ground resistance 500kΩ NA P
Tester: Date:24.01.2019
1 Start up voltage 350V NA P
2 Standby power (5, 10) W P
3 Max. output power (27500, 27500) W P
4 Max. output current (36.1, 41.7) A P
Max. conversion P
5 (98.6%, 98.3%)
Efficiency
Max. MPPT P
6 (99.9%, 100%)
Efficiency
Performance (0.8 leading C0.8 P
7 PF
and lagging)
protection 8 THDi <3% P
test 9 DCi (10, 50)mA P
UVP(240V
(240V rated) V<186V NA P
OVP(240V
(240V rated) V>243 NA P
10
UFP(60Hz
(60Hz rated) F<47.9Hz, NA P
OFP(60Hz
(60Hz rated) F>50.6Hz, NA P
14 Residual current protection >30mA NA P
Isolation resistance P
15 <500k NA
protection
Tester: Date:24.01.2019
Sealing test;
Check the surface—clean
clean and no scratch; check the LCD Board
Board—no P
scratch;
Check and confirm
rm the tightness of screws
screws; P
Check and confirm
rm the tightness of AC/DC terminal
terminal; P
Check the silk print—
—clear, in proper place, and with correct color; P
Inspection
Check the inside—no
no foreign material;
material P
Check the package—
—no humidity, subsidence, or smearing; P
Check the silk print (on package)—confirm
package) to the design drawing; P
Check the accessoriesies are complete, the nameplate is correct, and the P
entity is in accordance with the order requirement
requirement.
Tester: Date:24.01.2019